Advertisement for orthosearch.org.uk
Results 181 - 200 of 215
Results per page:
Bone & Joint Research
Vol. 1, Issue 12 | Pages 315 - 323
1 Dec 2012
Molt M Ljung P Toksvig-Larsen S

Objectives

The objective of this study was to compare the early migration characteristics and functional outcome of the Triathlon cemented knee prosthesis with its predecessor, the Duracon cemented knee prosthesis (both Stryker).

Methods

A total 60 patients were prospectively randomised and tibial component migration was measured by radiostereometric analysis (RSA) at three months, one year and two years; clinical outcome was measured by the American Knee Society score and the Knee Osteoarthritis and Injury Outcome Score.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 661 - 667
1 May 2010
van Riet RP Sanchez-Sotelo J Morrey BF

There is little information available at present regarding the mechanisms of failure of modern metallic radial head implants. Between 1998 and 2008, 44 consecutive patients (47 elbows) underwent removal of a failed metallic radial head replacement. In 13 patients (13 elbows) the initial operation had been undertaken within one week of a fracture of the radial head, at one to six weeks in seven patients (seven elbows) and more than six weeks (mean of 2.5 years (2 to 65 months)) in 22 patients (25 elbows). In the remaining two elbows the replacement was inserted for non-traumatic reasons. The most common indication for further surgery was painful loosening (31 elbows). Revision was undertaken for stiffness in 18 elbows, instability in nine, and deep infection in two. There were signs of over-lengthening of the radius in 11 elbows. Degenerative changes were found in all but one. Only three loose implants had been fixed with cement. Instability was not identified in any of the bipolar implants.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1045 - 1050
1 Aug 2012
Malek IA King A Sharma H Malek S Lyons K Jones S John A

Plasma levels of cobalt and chromium ions and Metal Artefact Reduction Sequence (MARS)-MRI scans were performed on patients with 209 consecutive, unilateral, symptomatic metal-on-metal (MoM) hip arthroplasties. There was wide variation in plasma cobalt and chromium levels, and MARS-MRI scans were positive for adverse reaction to metal debris (ARMD) in 84 hips (40%). There was a significant difference in the median plasma cobalt and chromium levels between those with positive and negative MARS-MRI scans (p < 0.001). Compared with MARS-MRI as the potential reference standard for the diagnosis of ARMD, the sensitivity of metal ion analysis for cobalt or chromium with a cut-off of > 7 µg/l was 57%. The specificity was 65%, positive predictive value was 52% and the negative predictive value was 69% in symptomatic patients. A lowered threshold of > 3.5 µg/l for cobalt and chromium ion levels improved the sensitivity and negative predictive value to 86% and 74% but at the expense of specificity (27%) and positive predictive value (44%).

Metal ion analysis is not recommended as a sole indirect screening test in the surveillance of symptomatic patients with a MoM arthroplasty. The investigating clinicians should have a low threshold for obtaining cross-sectional imaging in these patients, even in the presence of low plasma metal ion levels.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1113 - 1119
1 Aug 2012
Gjertsen J Lie SA Vinje T Engesæter LB Hallan G Matre K Furnes O

Using data from the Norwegian Hip Fracture Register, 8639 cemented and 2477 uncemented primary hemiarthroplasties for displaced fractures of the femoral neck in patients aged > 70 years were included in a prospective observational study. A total of 218 re-operations were performed after cemented and 128 after uncemented procedures. Survival of the hemiarthroplasties was calculated using the Kaplan-Meier method and hazard rate ratios (HRR) for revision were calculated using Cox regression analyses. At five years the implant survival was 97% (95% confidence interval (CI) 97 to 97) for cemented and 91% (95% CI 87 to 94) for uncemented hemiarthroplasties. Uncemented hemiarthroplasties had a 2.1 times increased risk of revision compared with cemented prostheses (95% confidence interval 1.7 to 2.6, p < 0.001). The increased risk was mainly caused by revisions for peri-prosthetic fracture (HRR = 17), aseptic loosening (HRR = 17), haematoma formation (HRR = 5.3), superficial infection (HRR = 4.6) and dislocation (HRR = 1.8). More intra-operative complications, including intra-operative death, were reported for the cemented hemiarthroplasties. However, in a time-dependent analysis, the HRR for re-operation in both groups increased as follow-up increased.

This study showed that the risk for revision was higher for uncemented than for cemented hemiarthroplasties.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 3 | Pages 344 - 347
1 Mar 2012
Wu T Chen P Chen C Wang C

It is difficult to determine the safe timing of weight-bearing or reconstructive surgery in patients with Charcot arthropathy of the foot and ankle. In this study the Doppler spectrum of the first dorsal metatarsal artery was used to monitor the activity of the disease activity and served as a guideline for management. A total of 15 patients (seven men and eight women) with acute diabetic Charcot arthropathy of the foot and ankle were immobilised in a non-weight-bearing cast. They were followed at two-week intervals and bilateral Doppler spectra of the first dorsal metatarsal arteries were obtained using a 10 MHz linear ultrasound probe. The patients were allowed to start weight-bearing or undergo surgery after the Doppler spectrum had returned to normal pattern. The Doppler spectra in the unaffected limbs were triphasic in pattern, whereas those in limbs with active Charcot arthropathy showed monophasic forward flow. They returned to normal after a mean of 13.6 weeks (6 to 20) of immobilisation. Three patients underwent pan-talar arthrodesis to correct gross instability and deformity.

Doppler spectrum analysis of the foot may reflect the activity of the disease in patients with Charcot arthropathy, and may be used as a guide to begin weight-bearing or undergo reconstructive surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1160 - 1169
1 Sep 2012
Bohm ER Tufescu TV Marsh JP

This review considers the surgical treatment of displaced fractures involving the knee in elderly, osteoporotic patients. The goals of treatment include pain control, early mobilisation, avoidance of complications and minimising the need for further surgery. Open reduction and internal fixation (ORIF) frequently results in loss of reduction, which can result in post-traumatic arthritis and the occasional conversion to total knee replacement (TKR). TKR after failed internal fixation is challenging, with modest functional outcomes and high complication rates. TKR undertaken as treatment of the initial fracture has better results to late TKR, but does not match the outcome of primary TKR without complications. Given the relatively infrequent need for late TKR following failed fixation, ORIF is the preferred management for most cases. Early TKR can be considered for those patients with pre-existing arthritis, bicondylar femoral fractures, those who would be unable to comply with weight-bearing restrictions, or where a single definitive procedure is required.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 5 | Pages 671 - 677
1 May 2012
Raiss P Sowa B Bruckner T Eck S Woerz S Rohr K Rickert M Kasten P

The aim of this study was to compare a third-generation cementing procedure for glenoid components with a new technique for cement pressurisation. In 20 pairs of scapulae, 20 keeled and 20 pegged glenoid components were implanted using either a third-generation cementing technique (group 1) or a new pressuriser (group 2). Cement penetration was measured by three-dimensional (3D) analysis of micro-CT scans. The mean 3D depth of penetration of the cement was significantly greater in group 2 (p < 0.001). The mean thickness of the cement mantle for keeled glenoids was 2.50 mm (2.0 to 3.3) in group 1 and 5.18 mm (4.4 to 6.1) in group 2, and for pegged glenoids it was 1.72 mm (0.9 to 2.3) in group 1 and 5.63 mm (3.6 to 6.4) in group 2. A cement mantle < 2 mm was detected less frequently in group 2 (p < 0.001). Using the cement pressuriser the proportion of cement mantles < 2 mm was significantly reduced compared with the third-generation cementing technique.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 281 - 286
1 Feb 2012
Chana R Esposito C Campbell PA Walter WK Walter WL

We report a case of a male patient presenting with bilateral painful but apparently well-positioned and -fixed large-diameter metal-on-metal hip replacements four years post-operatively. Multiple imaging modes revealed a thick-walled, cystic expansile mass in communication with the hip joint (a pseudotumour). Implant retrieval analysis and tissue culture eliminated high bearing wear or infection as causes for the soft-tissue reaction, but noted marked corrosion of the modular neck taper adaptor and corrosion products in the tissues. Therefore, we believe corrosion products from the taper caused by mismatch of the implant components led to pseudotumour formation requiring revision.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 80 - 85
1 Jan 2012
Malone AA Sanchez JS Adams R Morrey B

We report the effectiveness of revision of total elbow replacement by re-cementing. Between 1982 and 2004, 53 elbows in 52 patients were treated with re-cementing of a total elbow replacement into part or all of the existing cement mantle or into the debrided host-bone interface, without the use of structural bone augmentation or a custom prosthesis. The original implant revision was still in situ and functional in 42 of 53 elbows (79%) at a mean of 94.5 months (26 to 266) after surgery. In 31 of these 42 elbows (74%) the Mayo Elbow Performance Score was good or excellent. Overall, of the 53 elbows, 18 (34%) required re-operation, ten (19%) for loosening. A classification system was developed to identify those not suitable for revision by this technique, and using this we have showed that successful re-implantation is statistically correlated to properly addressing the bone deficiency for both the humeral (p = 0.005) and the ulnar (p = 0.039) components.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 16 - 22
1 Jan 2012
Popovic D King GJW

In light of the growing number of elderly osteopenic patients with distal humeral fractures, we discuss the history of their management and current trends. Under most circumstances operative fixation and early mobilisation is the treatment of choice, as it gives the best results. The relative indications for and results of total elbow replacement versus internal fixation are discussed.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1217 - 1222
1 Sep 2011
Bonner TJ Eardley WGP Patterson P Gregg PJ

Correct positioning and alignment of components during primary total knee replacement (TKR) is widely accepted to be an important predictor of patient satisfaction and implant durability. This retrospective study reports the effect of the post-operative mechanical axis of the lower limb in the coronal plane on implant survival following primary TKR.

A total of 501 TKRs in 396 patients were divided into an aligned group with a neutral mechanical axis (± 3°) and a malaligned group where the mechanical axis deviated from neutral by > 3°. At 15 years’ follow-up, 33 of 458 (7.2%) TKRs were revised for aseptic loosening. Kaplan-Meier survival analysis showed a weak tendency towards improved survival with restoration of a neutral mechanical axis, but this did not reach statistical significance (p = 0.47).

We found that the relationship between survival of a primary TKR and mechanical axis alignment is weaker than that described in a number of previous reports.


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 301 - 304
1 Mar 2013
Brennan SA Devitt BM O’Neill CJ Nicholson P

Focal femoral inlay resurfacing has been developed for the treatment of full-thickness chondral defects of the knee. This technique involves implanting a defect-sized metallic or ceramic cap that is anchored to the subchondral bone through a screw or pin. The use of these experimental caps has been advocated in middle-aged patients who have failed non-operative methods or biological repair techniques and are deemed unsuitable for conventional arthroplasty because of their age. This paper outlines the implant design, surgical technique and biomechanical principles underlying their use. Outcomes following implantation in both animal and human studies are also reviewed.

Cite this article: Bone Joint J 2013;95-B:301–4.


Bone & Joint 360
Vol. 2, Issue 1 | Pages 37 - 39
1 Feb 2013

The February 2013 Children’s orthopaedics Roundup360 looks at: the human genome; new RNA; cells, matrix and gene enhancement; the histology of x-rays; THR and VTE in the Danish population; potential therapeutic targets for GCT; optimising vancomycin elution from cement; and how much sleep is enough.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 1 | Pages 12 - 15
1 Jan 2005
Robertson A Lavalette D Morgan S Angus PD

We present the clinical and radiographic outcome of 68 consecutive primary total hip replacements performed in 54 patients under the age of 55 years using a hydroxyapatite-coated femoral component and threaded cup with a modular ceramic head (JRI-Furlong). We reviewed 62 (91%) hips at a median follow-up of 8.8 years (5 to 13.8) after implantation; six (9%) were lost to follow-up. At review there had been four (6%) revisions but only one for aseptic loosening (acetabulum). Radiographic review of the remaining hips did not identify any evidence of femoral or acetabular loosening. The median Harris and Merle d’Aubigné and Postel hip scores were 95.9 (42.7 to 100) and 17 (3 to 18) respectively. The JRI-Furlong hip gives promising functional and radiographic results in young patients in the medium term.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 6 | Pages 811 - 816
1 Jun 2010
Robinson CM Akhtar MA Jenkins PJ Sharpe T Ray A Olabi B

Displaced fractures of the lateral end of the clavicle in young patients have a high incidence of nonunion and a poor functional outcome after conservative management. Operative treatment is therefore usually recommended. However, current techniques may be associated with complications which require removal of the fixation device. We have evaluated the functional and radiological outcomes using a novel technique of open reduction and internal fixation. A series of 16 patients under 60 years of age with displaced fractures of the lateral end were treated by open reduction and fixation using a twin coracoclavicular endobutton technique. They were followed up for the first year after their injury.

At one year the mean Constant score was 87.1 and the median Disabilities of the Arm, Shoulder and Hand score was 3.3. All fractures had united, except in one patient who developed an asymptomatic fibrous union. One patient had post-traumatic stiffness of the shoulder, which resolved with physiotherapy. None required re-operation.

This technique produces good functional and radiological outcomes with a low prevalence of complications and routine implant removal is not necessary.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 11 | Pages 1443 - 1447
1 Nov 2009
Zenz P Stiehl JB Knechtel H Titzer-Hochmaier G Schwagerl W

Cementless acetabular fixation has demonstrated superior long-term durability in total hip replacement, but most series have studied implants with porous metal surfaces. We retrospectively evaluated the results of 100 consecutive patients undergoing total hip replacement where a non-porous Allofit component was used for primary press-fit fixation.

This implant is titanium alloy, grit-blasted, with a macrostructure of forged teeth and has a biradial shape. A total of 81 patients (82 hips) were evaluated at final follow-up at a mean of 10.1 years (8.9 to 11.9). The Harris Hip Score improved from a mean 53 points (23 to 73) pre-operatively to a mean of 96 points (78 to 100) at final review. The osseointegration of all acetabular components was radiologically evaluated with no evidence of loosening. The survival rate with revision of the component as the endpoint was 97.5% (95% confidence interval 94 to 100) after 11.9 years. Radiolucency was found in one DeLee-Charnley zone in four acetabular components. None of the implants required revision for aseptic loosening. Two patients were treated for infection, one requiring a two-stage revision of the implant. One femoral stem was revised for osteolysis due to the production of metal wear debris, but the acetabular shell did not require revision.

This study demonstrates that a non-porous titanium acetabular component with adjunct surface fixation offers an alternative to standard porous-coated implants.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 679 - 686
1 May 2010
Das De S Setiobudi T Shen L Das De S

There have been recent reports linking alendronate and a specific pattern of subtrochanteric insufficiency fracture. We performed a retrospective review of all subtrochanteric fractures admitted to our institution between 2001 and 2007. There were 20 patients who met the inclusion criteria, 12 of whom were on long-term alendronate. Alendronate-associated fractures tend to be bilateral (Fisher’s exact test, p = 0.018), have unique radiological features (p < 0.0005), be associated radiologically with a pre-existing ellipsoid thickening of the lateral femoral cortex and are likely to be preceded by prodromal pain. Biomechanical investigations did not suggest overt metabolic bone disease. Only one patient on alendronate had osteoporosis prior to the start of therapy. We used these findings to develop a management protocol to optimise fracture healing. We also advocate careful surveillance in individuals at-risk, and present our experience with screening and prophylactic fixation in selected patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 7 | Pages 889 - 895
1 Jul 2009
Gandhi R Tsvetkov D Davey JR Mahomed NN

Using meta-analysis we compared the survival and clinical outcomes of cemented and uncemented techniques in primary total knee replacement. We reviewed randomised controlled trials and observational studies comparing cemented and uncemented fixation. Our primary outcome was survival of the implant free of aseptic loosening. Our secondary outcome was joint function as measured by the Knee Society score. We identified 15 studies that met our final eligibility criteria. The combined odds ratio for failure of the implant due to aseptic loosening for the uncemented group was 4.2 (95% confidence interval (CI) 2.7 to 6.5) (p < 0.0001). Subgroup analysis of data only from randomised controlled trials showed no differences between the groups for odds of aseptic loosening (odds ratio 1.9, 95% CI 0.55 to 6.40, p = 0.314). The weighted mean difference for the Knee Society score was 0.005 (95% CI −0.26 to 0.26) (p = 0.972).

There was improved survival of the cemented compared to uncemented implants, with no statistically significant difference in the mean Knee Society score between groups for all pooled data.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 351 - 356
1 Mar 2009
Parratte S Argenson JA Pearce O Pauly V Auquier P Aubaniac J

We retrospectively reviewed 35 cemented unicompartmental knee replacements performed for medial unicompartmental osteoarthritis of the knee in 31 patients ≤50 years old (mean 46, 31 to 49). Patients were assessed clinically and radiologically using the Knee Society scores at a mean follow-up of 9.7 years (5 to 16) and survival at 12 years was calculated. The mean Knee Society Function Score improved from 54 points (25 to 64) pre-operatively to 89 (80 to 100) post-operatively (p < 0.0001). Six knees required revision, four for polyethylene wear treated with an isolated exchange of the tibial insert, one for aseptic loosening and one for progression of osteoarthritis.

The 12-year survival according to Kaplan-Meier was 80.6% with revision for any reason as the endpoint. Despite encouraging clinical results, polyethylene wear remains a major concern affecting the survival of unicompartmental knee replacement in patients younger than 50.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 12 | Pages 1580 - 1584
1 Dec 2008
Winkler H Stoiber A Kaudela K Winter F Menschik F

Infection of a total hip replacement (THR) requires component removal and thorough local debridement. Usually, long-term antibiotic treatment in conjunction with a two-stage revision is required. This may take several months. One-stage revision using antibiotic-loaded cement has not gained widespread use, although the clinical and economic advantages are obvious. Allograft bone may be impregnated with high levels of antibiotics, and in revision of infected THR, act as a carrier providing a sustained high local concentration.

We performed 37 one-stage revision of infected THRs, without the use of cement. There were three hips which required further revision because of recurrent infection, the remaining 34 hips (92%) stayed free from infection and stable at a mean follow-up of 4.4 years (2 to 8). No adverse effects were identified. Incorporation of bone graft was comparable with unimpregnated grafts.

Antibiotic-impregnated allograft bone may enable reconstruction of bone stock, insertion of an uncemented implant and control of infection in a single operation in revision THR for infection.