Advertisement for orthosearch.org.uk
Results 181 - 200 of 4287
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 2 | Pages 183 - 189
1 Mar 1997
Pihlajamäki H Myllynen P Böstman O

We analysed the complications encountered in 102 consecutive patients who had posterolateral lumbosacral fusion performed with transpedicular screw and rod fixation for non-traumatic disorders after a minimum of two years. Of these, 40 had spondylolysis and spondylolisthesis, 42 a degenerative disorder, 14 instability after previous laminectomy and decompression, and six pain after nonunion of previous attempts at spinal fusion without internal fixation. There were 75 multilevel and 27 single-level fusions. There were 76 individual complications in 48 patients, and none in the other 54. The complications seen were screw misplacement, coupling failure of the device, wound infection, nonunion, permanent neural injury, and loosening, bending and breakage of screws. Screw breakage or loosening was more common in patients with multilevel fusions (p < 0.001). Screws of 5 mm diameter should not be used for sacral fixation. Forty-six patients had at least one further operation for one or several complications, including 20 fusion procedures for nonunion. The high incidence of complications is a disadvantage of this technically-demanding method


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 8 | Pages 1150 - 1155
1 Nov 2002
Parker MJ Khan RJK Crawford J Pryor GA

A total of 455 patients aged over 70 years with a displaced intracapsular fracture of the proximal femur was randomised to be treated either by hemiarthroplasty or internal fixation. The preoperative characteristics of the patients in both groups were similar. Internal fixation has a shorter length of anaesthesia (36 minutes versus 57 minutes, p < 0.0001), lower operative blood loss (28 ml versus 177 ml, p < 0.0001) and lower transfusion requirements (0.04 units versus 0.39 units, p < 0.0001). In the internal fixation group 90 patients required 111 additional surgical procedures while only 15 additional operations on the hip were needed in 12 patients in the arthroplasty group. There was no statistically significant difference in mortality between the groups at one year (61/226 versus 63/229, p = 0.91), but there was a tendency for an improved survival in the older less mobile patients treated by internal fixation. For the survivors assessed at one, two and three years from injury there were no differences with regard to the outcome for pain and mobility. Limb shortening was more common after internal fixation (7.0 mm versus 3.6 mm, p = 0.004). We recommend that displaced intracapsular fractures in the elderly should generally be treated by arthroplasty but that internal fixation may be appropriate for those who are very frail


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 39 - 44
1 Jan 2007
Uvehammer J Kärrholm J Carlsson L

We have carried out a radiostereometric study of 50 patients (54 knees) with osteoarthritis of the knee who were randomly allocated to receive a cemented or a hydroxyapatite-coated femoral component for total knee replacement. The patients were also stratified to receive one of three types of articulating surface (standard, rotating platform, Freeman-Samuelson (FS)1000) all based on the Freeman-Samuelson design. The tibial components were cemented in all cases. Radiostereometry was performed post-operatively and at 3, 12 and 24 months. The analysis was restricted to rotation of the femoral component over time. After two years, rotation of the femoral components in the transverse, longitudinal and sagittal planes did not differ between the cemented and the hydroxyapatite-coated implants (p = 0.2 to 0.9). In total knee replacements with a rotating platform, the femoral component tended to tilt more posteriorly than in the other two designs, regardless of the choice of fixation (cemented or hydroxyapatite-coated, p = 0.04). The standard version of the femoral component, whether cemented or hydroxyapatite-coated, rotated more into valgus than was observed with the rotating-platform and FS1000 designs (p = 0.005). The increased constraint provided by the FS1000 component did not appear to have any adverse effect on fixation of the femoral component


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 4 | Pages 725 - 731
1 Jul 1999
Overgaard S Bromose U Lind M Bünger C Søballe K

We inserted two hydroxyapatite (HA)-coated implants with crystallinities of either 50% (HA-50%) or 75% (HA-75%) bilaterally into the medial femoral condyles of the knees of 16 dogs. The implants were allocated to two groups with implantation periods of 16 and 32 weeks. They were weight-bearing and subjected to controlled micromovement of 250 μm during each gait cycle. After 16 weeks, mechanical fixation of the HA-50% implants was increased threefold as compared with the HA-75% implants. After 32 weeks there was no difference between HA-50% and HA-75%. Fixation of HA-75% increased from 16 to 32 weeks whereas that of HA-50% was unchanged. HA-50% implants had 100% more bone ingrowth than HA-75% implants after 16 weeks. More HA coating was removed on HA-50% implants compared with HA-75% implants after both 16 and 32 weeks. No further loss of the HA coating was shown from 16 to 32 weeks. Our study suggests that the crystallinity of the HA coating is an important factor in its bioactivity and resorption during weight-bearing conditions. Our findings suggest two phases of coating resorption, an initial rapid loss, followed by a slow loss. Resorbed HA coating was partly replaced by bone ingrowth, suggesting that implant fixation will be durable


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 3 | Pages 487 - 489
1 May 1997
Magyar G Toksvig-Larsen S Moroni A

We measured the insertion and extraction torque forces in a randomised study of 76 external fixation screws in 19 patients treated by hemicallotasis for osteoarthritis of the medial side of the knee. The patients were randomised to have either standard tapered screws (Orthofix 6/5 mm) or the same screws with hydroxyapatite (HA) coating. One patient had two standard and two HA-coated screws. All patients had an anterior external fixator (Orthofix T-garche), with two screws in the proximal tibial metaphysis parallel to and about 2 cm below the joint surface and two in the tibial diaphysis. The mean torque forces for insertion of the standard screws were 260 Ncm for the proximal to medial screw, 208 for the proximal to lateral screw and 498 and 546 Ncm for the diaphyseal pins. The corresponding forces for the HA-coated pins were not significantly different. The torque forces for the extraction of the standard pins were 2 Ncm for the proximal pins, 277 and 249 Ncm for the distal pins and 482, 478, 585 and 620 Ncm, respectively (p < 0.005) for the HA-coated pins. All 18 of the metaphyseal standard screws were loose at extraction (extraction force < 20 Ncm), but only one of the HA screws in the metaphysis was loose. In the diaphysis the standard screws lost about 40% of their fixation in contrast to the HA-coated screws which retained full fixation strength


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 4 | Pages 562 - 567
1 Jul 1995
Lenoble E Dumontier C Goutallier D Apoil A

We performed a prospective study on 96 patients with extra-articular or intra-articular fractures of the distal radius with a dorsally displaced posteromedial fragment. After closed reduction, we compared trans-styloid fixation and immobilisation with Kapandji fixation and early mobilisation. Forty-two patients of mean age 57.1 years +/- 18.1 (SD) were treated by trans-styloid K-wire fixation and 45 days of short-arm cast immobilisation. Fifty-four patients of mean age 57.7 years +/- 18.7 (SD) had Kapandji fixation and immediate mobilisation according to the originator. All the patients had clinical and radiological review at about six weeks and at 3, 6, 12 and 24 months after the operation. Pain, range of movement and grip strength were tested clinically, and changes in dorsal tilt, radial tilt, ulnar variance, and radial shortening were assessed radiologically. Statistical analysis was applied to comparisons with the normal opposite wrist. Pain and reflex sympathetic dystrophy were more frequent after Kapandji fixation and early mobilisation, but the range of motion was better although this became statistically insignificant after six weeks. The radiological reduction was better soon after Kapandji fixation, but there was some loss of reduction and increased radial shortening during the first three postoperative months. The clinical result at two years was similar in both groups


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 3 | Pages 417 - 425
1 May 1998
Önsten I Nordqvist A Carlsson ÅS Besjakov J Shott S

In a single-blind, randomised series of knee replacements in 116 patients, we used radiostereometric analysis (RSA) to measure micromotion in three types of tibial implant fixation for two years after knee replacement. We compared hydroxyapatite-augmented porous coating, porous coating, and cemented fixation of the same design of tibial component. At one to two years, porous-coated implants migrated at a statistically significantly higher rate than hydroxyapatite-augmented or cemented implants. There was no significant difference between hydroxyapatite-coated and cemented implants. We conclude that hydroxyapatite augmentation may offer a clinically relevant advantage over a simple porous coating for tibial component fixation, but is no better than cemented fixation


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 1 | Pages 66 - 71
1 Jan 2008
McQueen MM Gelbke MK Wakefield A Will EM Gaebler C

We randomly allocated 60 consecutive patients with fractures of the waist of the scaphoid to percutaneous fixation with a cannulated Acutrak screw or immobilisation in a cast. The range of movement, the grip and pinch strength, the modified Green/O’Brien functional score, return to work and sports, and radiological evidence of union were evaluated at each follow-up visit. Patients were followed sequentially for one year. Those undergoing percutaneous screw fixation showed a quicker time to union (9.2 weeks vs 13.9 weeks, p < 0.001) than those treated with a cast. There was a trend towards a higher rate of nonunion in the non-operative group, although this was not statistically significant. Patients treated by operation had a more rapid return of function and to sport and full work compared with those managed conservatively. There was a very low complication rate. We recommend that all active patients should be offered percutaneous stabilisation for fractures of the waist of the scaphoid


The Journal of Bone & Joint Surgery British Volume
Vol. 55-B, Issue 3 | Pages 618 - 620
1 Aug 1973
Sharp IK

1. A technique for internal fixation of the disrupted symphysis pubis by an angled four-hole plate is described. 2. In five patients in whom internal fixation was used rapid relief of the severe discomfort caused by symphysial disruption was noted


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 4 | Pages 502 - 508
1 Apr 2006
Robinson CM Khan LAK Akhtar MA

Over a seven-year period we treated a consecutive series of 58 patients, 20 men and 38 women with a mean age of 66 years (21 to 87) who had an acute complex anterior fracture-dislocation of the proximal humerus. Two patterns of injury are proposed for study based upon a prospective assessment of the pattern of soft-tissue and bony injury and the degree of devascularisation of the humeral head. In 23 patients, the head had retained capsular attachments and arterial back-bleeding (type-I injury), whereas in 35 patients the head was devoid of significant soft-tissue attachments with no active arterial bleeding (type-II injury). Following treatment by open reduction and internal fixation, only two of 23 patients with type-I injuries developed radiological evidence of osteonecrosis of the humeral head, compared with four of seven patients with type-II injuries. A policy of primary treatment by open reduction and internal fixation of type-I injuries is justified, whereas most elderly patients (aged 60 years or over) with type-II injuries are best treated by hemiarthroplasty. The best treatment for younger patients (aged under 60 years) who sustain type-II injuries is controversial and an individualised approach to their management is advocated


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 4 | Pages 615 - 619
1 Aug 1987
Bostman O Vainionpaa S Hirvensalo E Makela A Vihtonen K Tormala P Rokkanen P

Fifty-six patients with displaced malleolar fractures had open reduction and fixation of the fracture fragments using, by random selection, either biodegradable implants or metal AO plates and screws. The cylindrical biodegradable implants were made of polylactide-glycolide copolymer (polyglactin 910). The complications, radiographic results and functional recovery were studied prospectively. After follow-up of at least one year, no significant differences emerged in the complication rate or in the results of treatment between the two methods of fixation. Because of the advantage of avoiding the need to remove metal fixation after union, we now use biodegradable internal fixation routinely to treat displaced malleolar fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 2 | Pages 267 - 269
1 Mar 1995
Pritchett J

Fifty patients with complex distal radial fractures treated by primary external fixation were compared with 50 with similar fractures treated by closed medullary pinning. All the patients had Frykman type-VIII injuries. The two groups were similar in regard to demographic characteristics and the method of treatment was randomly chosen. All the fractures healed within three months. In the external fixation group 92% of fractures healed in excellent alignment as did 88% of the medullary pinning group. Both groups had similar results with respect to eventual function, range of motion, and grip strength. Complications and complaints were fewer and the estimated costs of treatment were significantly less in the medullary pinning group. More patients were satisfied with closed medullary fixation than with external fixation


The Journal of Bone & Joint Surgery British Volume
Vol. 43-B, Issue 4 | Pages 680 - 687
1 Nov 1961
Hicks JH

1. A series of fractures of the forearm has been treated by exceptionally rigid internal fixation with a special plate and screws. 2. The plate and screws are described. 3. The results of rigid fixation are found to be: i) reliability of union, and ii) good final function. 4. The lessons learned regarding the application of the plate and the after-treatment of the forearms are recounted


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 4 | Pages 644 - 648
1 Aug 1988
Clifford R Beauchamp C Kellam J Webb J Tile M

The results of immediate plate fixation of 97 open fractures of the tibial shaft in 95 patients are reported. Significant joint stiffness occurred in 11.4% and angular malunion of greater than 5 degrees in any plane was seen in 3.1%. The infection rate was 10.3%. However, even in those cases which develop delayed union or other complications, plate fixation of open fractures can produce excellent recovery of limb function


The Journal of Bone & Joint Surgery British Volume
Vol. 46-B, Issue 2 | Pages 206 - 211
1 May 1964
Denham RA

Two hundred and thirty-two ankle fractures were treated in the orthopaedic department of the Royal Portsmouth Hospital between 1959 and 1960. Seventy-one fractures treated by internal fixation with screws have been seen at follow-up examination. Results show that open reduction, secure and accurate internal fixation and early movement without plaster or other splintage is a treatment which in most cases has been followed by a short convalescence, few post-operative complications, and a painless ankle and with good function


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1144 - 1150
1 Sep 2019
Tsuda Y Fujiwara T Sree D Stevenson JD Evans S Abudu A

Aims

The aim of this study was to report the results of custom-made endoprostheses with extracortical plates plus or minus a short, intramedullary stem aimed at preserving the physis after resection of bone sarcomas in children.

Patients and Methods

Between 2007 and 2017, 18 children aged less than 16 years old who underwent resection of bone sarcomas, leaving ≤ 5 cm of bone from the physis, and reconstruction with a custom-made endoprosthesis were reviewed. Median follow-up was 67 months (interquartile range 45 to 91). The tumours were located in the femur in 11 patients, proximal humerus in six, and proximal tibia in one.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 5 | Pages 748 - 752
1 Sep 1997
Song H Cho S Jeong S Park Y Koo K

Stable fixation after a corrective supracondylar osteotomy in adults is difficult because of the irregularity of the area of bony contact, displacement of the fragments, the predominance of cortical bone, and the need for early mobilisation. We have used the Ilizarov apparatus for fixation in 15 patients who were treated by complex osteotomies with displacement of fragments for cubitus varus or valgus. Most patients with cubitus varus required medial displacement with rotation of the distal fragment. Those with cubitus valgus required lateral shift of the distal fragment to reduce the medial prominence of the elbow that would otherwise result. All osteotomies united within the expected time without loss of correction, despite early mobilisation. Complications related to the fixation were few and had resolved at the long-term follow-up


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 229 - 236
1 Feb 2011
Briffa N Pearce R Hill AM Bircher M

We report the outcome of 161 of 257 surgically fixed acetabular fractures. The operations were undertaken between 1989 and 1998 and the patients were followed for a minimum of ten years. Anthropometric data, fracture pattern, time to surgery, associated injuries, surgical approach, complications and outcome were recorded. Modified Merle D’Aubigné score and Matta radiological scoring systems were used as outcome measures. We observed simple fractures in 108 patients (42%) and associated fractures in 149 (58%). The result was excellent in 75 patients (47%), good in 41 (25%), fair in 12 (7%) and poor in 33 (20%). Poor prognostic factors included increasing age, delay to surgery, quality of reduction and some fracture patterns. Complications were common in the medium- to long-term and functional outcome was variable. The gold-standard treatment for displaced acetabular fractures remains open reduction and internal fixation performed in dedicated units by specialist surgeons as soon as possible


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 2 | Pages 227 - 230
1 Mar 1998
Drenth DJ Klasen HJ

From 1987 to 1993 we treated 33 patients with 29 phalangeal and seven metacarpal fractures by external fixation using a mini-Hoffmann device. There were 27 open and 25 comminuted fractures. In 12 patients one or more tendons was involved. The mean follow-up was 4.4 years. Complications occurred in ten fractures; two required repositioning of the fixator. All the fractures healed. The functional results after metacarpal fractures were better than those after phalangeal fractures and fractures of the middle phalanx had better recovery than those of the proximal phalanx. Twenty-eight of the 33 patients were satisfied with their result. External fixation proved to be a suitable technique for stabilising unstable, open fractures with severe soft-tissue injuries


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 11 | Pages 1499 - 1506
1 Nov 2008
Rammelt S Schneiders W Schikore H Holch M Heineck J Zwipp H

Fracture-dislocations of the tarsometatarsal (Lisfranc) joints are frequently overlooked or misdiagnosed at initial presentation. This is a comparative cohort study over a period of five years comparing primary open reduction and internal fixation in 22 patients (23 feet) with secondary corrective arthrodesis in 22 patients (22 feet) who presented with painful malunion at a mean of 22 months (1.5 to 45) after injury. In the first group primary treatment by open reduction and internal fixation for eight weeks with Kirschner-wires or screws was undertaken, in the second group treatment was by secondary corrective arthrodesis. There was one deep infection in the first group. In the delayed group there was one complete and one partial nonunion. In each group 20 patients were available for follow-up at a mean of 36 months (24 to 89) after operation. The mean American Orthopaedic Foot and Ankle Society midfoot score was 81.4 (62 to 100) after primary treatment and 71.8 (35 to 88) after corrective arthrodesis (t-test; p = 0.031). We conclude that primary treatment by open reduction and internal fixation of tarsometatarsal fracture-dislocations leads to improved functional results, earlier return to work and greater patient satisfaction than secondary corrective arthrodesis, which remains a useful salvage procedure providing significant relief of pain and improvement in function