Of 48 consecutive children with Gartland III
supracondylar fractures, 11 (23%) had evidence of vascular injury,
with an absent radial pulse. The hand was pink and warm in eight
and white and cold in the other three patients. They underwent colour-coded
duplex scanning (CCDS) and ultrasound velocimetry (UV) to investigate
the patency of the brachial artery and arterial blood flow. In seven
patients with a pink pulseless hand, CCDS showed a displaced, kinked
and spastic brachial artery and a thrombosis was present in the
other. In all cases UV showed reduced blood flow in the hand. In
three patients with a white pulseless hand, scanning demonstrated
a laceration in the brachial artery and/or thrombosis. In all cases,
the fracture was reduced under general anaesthesia and fixed with
Kirschner wires. Of the seven patients with a pink pulseless hand
without thrombosis, the radial pulse returned after reduction in
four cases. The remaining three underwent exploration, along with
the patients with laceration in the brachial artery and/or thrombosis. We believe that the traditional strategy of watchful waiting
in children in whom the radial pulse remains absent in spite of
good peripheral perfusion should be revisited. Vascular investigation
using these non-invasive techniques that are quick and reliable
is recommended in the management of these patients. Cite this article:
The December 2012 Wrist &
Hand Roundup360 looks at: the imaging of scaphoid fractures; splinting to help Dupuytren’s disease; quality of life after nerve transfers; early failure of Moje thumbs; electra CMCJ arthroplasty; proximal interphalangeal joint replacement; pronator quadratus repair in distal radius fractures; and osteoporosis and wrist fractures.
Acetabular labral tears and associated intra-articular
pathology of the hip have been recognised as a source of symptoms.
However, it is now appreciated that there is a relatively high prevalence
of asymptomatic labral tears. In this study, 70 young asymptomatic
adult volunteers with a mean age of 26 years (19 to 41) were recruited
and underwent three tesla non-arthrographic MR scans. There were
47 women (67.1%) and 23 men (32.9%). Labral tears were found in 27 volunteers (38.6%); these were
an isolated finding in 16 (22.9%) and were associated with other
intra-articular pathology in the remaining 11 (15.7%) volunteers.
Furthermore, five (7.1%) had intra-articular pathology without an
associated labral tear. Given the high prevalence of labral pathology in the asymptomatic
population, it is important to confirm that a patient's symptoms
are due to the demonstrated abnormalities when considering surgery. Cite this article:
Lengthening osteotomies of the calcaneus in children are in general
grafted with bone from the iliac crest. Artificial bone grafts have
been introduced, however, their structural and clinical durability
has not been documented. Radiostereometric analysis (RSA) is a very
accurate and precise method for measurements of rigid body movements including
the evaluation of joint implant and fracture stability, however,
RSA has not previously been used in clinical studies of calcaneal
osteotomies. We assessed the precision of RSA as a measurement tool
in a lateral calcaneal lengthening osteotomy (LCLO). LCLO was performed in six fixed adult cadaver feet. Tantalum
markers were inserted on each side of the osteotomy and in the cuboideum.
Lengthening was done with a plexiglas wedge. A total of 24 radiological
double examinations were obtained. Two feet were excluded due to
loose and poorly dispersed markers. Precision was assessed as systematic
bias and 95% repeatability limits.Objectives
Methods
The December 2014 Wrist &
Hand Roundup360 looks at: ultrasound for carpal tunnel diagnosis; where we are at with management of undisplaced scaphoid fractures; ARPE for thumb metacarpals?; extravasation injuries in the hand and wrist; research and practice in hand surgery; and physio ineffective in hand osteoarthritis
The purpose of this study was to evaluate whether
the serum level of interleukin 6 (IL-6) could be used to identify the
persistence of infection after the first stage of a two-stage revision
for periprosthetic joint infection. Between 2010 and 2011, we prospectively studied 55 patients (23
men, 32 women; mean age 69.5 years; 36 to 86) with a periprosthetic
joint infection. Bacteria were identified in two intra-operative
tissue samples during re-implantation in 16 patients. These cases
were classified as representing persistent infection. To calculate a precise cut-off value which could be used in everyday
clinical practice, a 3 x 2 contingency table was constructed and
manually defined. We found that a serum IL-6 ≥ 13 pg/mL can be regarded as indicating
infection: its positive-predictive value is 90.9%. A serum IL-6 ≤ 8
pg/mL can be regarded as indicating an absence of infection: its
negative predictive value is 92.1%. The serum IL-6 level seems to be a reasonable marker for identifying
persistent infection after the first stage of a revision joint arthroplasty
and before attempting re-implantation. Cite this article:
The June 2012 Hip &
Pelvis Roundup360 looks at: whether metal-on-metal is really such a disaster; resurfacings with unexplained pain; large heads and high ion levels; hip arthroscopy for FAI; the inaccuracy of clinical tests for impingement; arthroscopic lengthening of iliopsoas; the OA hip; the injured hamstring – football’s most common injury; an algorithm for hip fracture surgery; and sparing piriformis at THR.
The lack of an accurate, rapid diagnostic test
for mycobacterium tuberculosis (TB) is a major handicap in the management
of spinal TB. GeneXpert, a new, rapid molecular diagnostic test
is recommended as the first line investigation for suspected pulmonary
TB in areas with a high prevalence of HIV or drug resistance, yet
it has not been validated for the diagnosis of musculoskeletal TB. The aim of this study was to assess the accuracy of GeneXpert
in diagnosing spinal TB. A prospective clinical study of 69 consecutive adults with suspected
spinal TB was conducted at a tertiary hospital in an area with the
highest incidence and prevalence of TB in the world. GeneXpert was
used on tissue samples of the enrolled patients and its diagnostic
accuracy compared with a reference standard of tissue in liquid culture.
A total of 71 spine samples from 69 patients (two re-biopsies) were
included in the study. The GeneXpert test showed a sensitivity of 95.6% and specificity
of 96.2% for spinal TB. The results of the GeneXpert test were available
within 48 hours compared with a median of 35 days (IQR 15 to 43)
for cultures. All cases of multi-drug resistant TB (MDR TB) were
diagnosed accurately with the GeneXpert test. The MDR TB rate was
5.8%. Cite this article:
The August 2014 Hip &
Pelvis Roundup360 looks at: Serial MRIs best for pseudotumour surveillance; Is ultrasound good enough for MOM follow-up?; Does weight loss in obese patients help?; Measuring acetabular anteversion on plain films; Two-stage one-stage too many in fungal hip revisions? and 35 is the magic number in arthroplasty.
The August 2014 Knee Roundup360 looks at: re-admission following total knee replacement; out with the old and in with the new? computer navigation revisited; approach less important in knee replacement; is obesity driving a rise in knee replacements?; knee replacement isn’t cheap in the obese; cruciate substitution doesn’t increase knee flexion; and sonication useful diagnostic aid in two-stage revision.
Our aim was to determine the clinical value of MRI and CT arthrography in predicting the presence of loose bodies in the elbow. A series of 26 patients with mechanical symptoms in the elbow had plain radiography, MRI and CT arthrography, followed by routine arthroscopy of the elbow. The location and number of loose bodies determined by MRI and CT arthrography were recorded. Pre-operative plain radiography, MRI and CT arthrography were compared with arthroscopy. Both MRI and CT arthrography had excellent sensitivity (92% to 100%) but low to moderate specificity (15% to 77%) in identifying posteriorly-based loose bodies. Neither MRI nor CT arthrography was consistently sensitive (46% to 91%) or specific (13% to 73%) in predicting the presence or absence of loose bodies anteriorly. The overall sensitivity for the detection of loose bodies in either compartment was 88% to 100% and the specificity 20% to 70%. Pre-operative radiography had a similar sensitivity and specificity of 84% and 71%, respectively. Our results suggest that neither CT arthrography nor MRI is reliable or accurate enough to be any more effective than plain radiography alone in patients presenting with mechanical symptoms in the elbow.
The December 2014 Knee Roundup360 looks at: national guidance on arthroplasty thromboprophylaxis is effective; unicompartmental knee replacement has the edge in terms of short-term complications; stiff knees, timing and manipulation; neuropathic pain and total knee replacement; synovial fluid α-defensin and CRP: a new gold standard in joint infection diagnosis?; how to assess anterior knee pain?; where is the evidence? Five new implants under the spotlight; and a fresh look at ACL reconstruction
The August 2014 Foot &
Ankle Roundup360 looks at: calcaneotibial nail in ankle fractures; reamer irrigator aspirator for ankle fusion; periprosthetic bone infection; infection in ankle fixation; cheap and cheerful OK in MTP fusion plates; sliding fibular graft for peroneal tendon pathology and fusion for failed ankle replacement.
In this meta-analysis we included 32 English-language articles published between January 1975 and June 2004 on the diagnostic performance of plain radiography, subtraction arthrography, nuclear arthrography and bone scintigraphy in detecting aseptic loosening of the femoral component, using criteria based on the Cochrane systematic review of screening and diagnostic tests. The mean sensitivity and specificity were, respectively, 82% (95% confidence interval (CI) 76 to 87) and 81% (95% CI 73 to 87) for plain radiography and 85% (95% CI 75 to 91) and 83% (95% CI 75 to 89) for nuclear arthrography. Pooled sensitivity and specificity were, respectively, 86% (95% CI 74 to 93) and 85% (95% CI 77 to 91) for subtraction arthrography and 85% (95% CI 79 to 89) and 72% (95% CI 64 to 79) for bone scintigraphy. Although the diagnostic performance of the imaging techniques was not significantly different, plain radiography and bone scintigraphy are preferred for the assessment of a femoral component because of their efficacy and lower risk of patient morbidity.
There is no diagnostic, non-invasive method for the early detection of loosening after total hip arthroplasty. In a pilot study, we have analysed two serum markers of bone remodelling, procollagen I C-terminal extension peptide (PICP) and cross-linked N-terminal telopeptide (NTx), as well as the diagnostic performance of NTx for the assessment of osteolysis. We recruited 21 patients with loosening (group I), 18 with a well-fixed prosthesis (group II) and 17 at the time of primary arthroplasty for osteoarthritis (OA) (group III). Internal normal reference ranges were obtained from 30 healthy subjects (group IV). The serum PICP level was found to be significantly lower in patients with OA and those with loosening, when compared with those with stable implants, while the NTx level was significantly increased only in the group with loosening, suggesting that collagen degradation depended on the altered bone turnover induced by the implant. This hypothesis was reinforced by the finding that the values in the pre-surgery patients and stable subjects were comparable with the reference range of younger healthy subjects. A high specificity and positive predictive value for NTx provided good diagnostic evidence of agreement between the test and the clinical and radiological evaluations. The NTx level could be used to indicate stability of the implant. However, further prospective, larger studies are necessary.
A suspected fracture of the scaphoid remains difficult to manage despite advances in knowledge and imaging methods. Immobilisation and restriction of activities in a young and active patient must be balanced against the risks of nonunion associated with an undiagnosed and undertreated fracture of the scaphoid. The assessment of diagnostic tests for a suspected fracture of the scaphoid must take into account two important factors. First, the prevalence of true fractures among suspected fractures is low, which greatly reduces the probability that a positive test will correspond with a true fracture, as false positives are nearly as common as true positives. This situation is accounted for by Bayesian statistics. Secondly, there is no agreed reference standard for a true fracture, which necessitates the need for an alternative method of calculating diagnostic performance characteristics, based upon a statistical method which identifies clinical factors tending to associate (latent classes) in patients with a high probability of fracture. The most successful diagnostic test to date is MRI, but in low-prevalence situations the positive predictive value of MRI is only 88%, and new data have documented the potential for false positive scans. The best strategy for improving the diagnosis of true fractures among suspected fractures of the scaphoid may well be to develop a clinical prediction rule incorporating a set of demographic and clinical factors which together increase the pre-test probability of a fracture of the scaphoid, in addition to developing increasingly sophisticated radiological tests.
The December 2013 Trauma Roundup360 looks at: Re-operation for intertrochanteric hip fractures; Are twin incisions better than one round the acetabulum?; Salvage osteotomy for calcaneal fractures; Posterior dislocation; Should MRSA be covered in open fractures?; Characterising the saline load test; Has it healed: hip fractures under the spotlight; and stem cells present in atrophic non-union.
The February 2013 Children’s orthopaedics Roundup360 looks at: ABC treated with suction and curettage; peri-acetabular osteotomy; cast index; Perthes’ disease associated with accidental injury; brachial plexus birth palsy; MRI assessment of DDH; total meniscectomy; and paediatric septic arthritis.
The February 2013 Hip &
Pelvis Roundup360 looks at: amazing alumina; dual mobility; white cells and periprosthetic infection; cartilage and impingement surgery; acetabulum in combination; cementless ceramic prosthesis; metal-on-metal hips; and whether size matters in failure.
The most appropriate protocol for the biopsy of musculoskeletal tumours is controversial, with some authors advocating CT-guided core biopsy. At our hospital the initial biopsies of most musculoskeletal tumours has been by operative core biopsy with evaluation by frozen section which determines whether diagnostic tissue has been obtained and, if possible, gives the definitive diagnosis. In order to determine the accuracy and cost-effectiveness of this protocol we have undertaken a retrospective audit of biopsies of musculoskeletal tumours performed over a period of two years. A total of 104 patients had biopsies according to this regime. All gave the diagnosis apart from one minor error which did not alter the management of the patient. There was no requirement for re-biopsy. This protocol was more labour-intensive and 38% more costly than CT-guided core biopsy (AU$1804