Aims. Although absorbable sutures for the repair of acute Achilles tendon rupture (ATR) have been attracting attention, the rationale for their use remains insufficient. This study prospectively compared the outcomes of absorbable and nonabsorbable sutures for the repair of acute ATR. Methods. A total of 40 patients were randomly assigned to either braided absorbable polyglactin suture or braided nonabsorbable polyethylene terephthalate suture groups. ATR was then repaired using the Krackow suture method. At three and six months after surgery, the isokinetic muscle
Aims. To develop an early implant instability murine model and explore the use of intermittent parathyroid hormone (iPTH) treatment for initially unstable implants. Methods. 3D-printed titanium implants were inserted into an oversized drill-hole in the tibiae of C57Bl/6 mice (n = 54). After implantation, the mice were randomly divided into three treatment groups (phosphate buffered saline (PBS)-control, iPTH, and delayed iPTH). Radiological analysis, micro-CT (µCT), and biomechanical pull-out testing were performed to assess implant loosening, bone formation, and osseointegration. Peri-implant tissue formation and cellular composition were evaluated by histology. Results. iPTH reduced radiological signs of loosening and led to an increase in peri-implant bone formation over the course of four weeks (timepoints: one week, two weeks, and four weeks). Observational histological analysis shows that iPTH prohibits the progression of fibrosis. Delaying iPTH treatment until after onset of peri-implant fibrosis still resulted in enhanced osseointegration and implant stability. Despite initial instability, iPTH increased the mean pull-out
Aims. Anchorage of pedicle screw rod instrumentation in the elderly spine with poor bone quality remains challenging. Our study aims to evaluate how the screw bone anchorage is affected by screw design, bone quality, loading conditions, and cementing techniques. Methods. Micro-finite element (µFE) models were created from micro-CT (μCT) scans of vertebrae implanted with two types of pedicle screws (L: Ennovate and R: S. 4. ). Simulations were conducted for a 10 mm radius region of interest (ROI) around each screw and for a full vertebra (FV) where different cementing scenarios were simulated around the screw tips. Stiffness was calculated in pull-out and anterior bending loads. Results. Experimental pull-out
Aims. To draw a comparison of the pullout
Aims. Rotational acetabular osteotomy (RAO) is an effective joint-preserving surgical treatment for acetabular dysplasia. The purpose of this study was to investigate changes in muscle
Recognized anatomic variations that lead to patella instability include patella alta and trochlea dysplasia. Lateralization of the extensor mechanism relative to the trochlea is often considered to be a contributing factor; however, controversy remains as to the degree this contributes to instability and how this should be measured. As the tibial tuberosity-trochlear groove (TT-TG) is one of most common imaging measurements to assess lateralization of the extensor mechanism, it is important to understand its
Aims. Loosening of the tibial component after total knee arthroplasty (TKA) is a common indication for revision. Increasing the
Objectives. Screw plugs have been reported to increase the fatigue
Objectives. Bisphosphonates (BP) are the first-line treatment for preventing fragility fractures. However, concern regarding their efficacy is growing because bisphosphonate is associated with over-suppression of remodelling and accumulation of microcracks. While dual-energy X-ray absorptiometry (DXA) scanning may show a gain in bone density, the impact of this class of drug on mechanical properties remains unclear. We therefore sought to quantify the mechanical
The benefit of MRI in the preoperative assessment of scaphoid proximal fragment vascularity remains controversial. The purpose of this study is to compare preoperative MRI findings to intraoperative bleeding of the proximal scaphoid. A retrospective review of 102 patients who underwent surgery for scaphoid nonunion between January 2000 and December 2020 at a single institution were identified. Inclusion criteria were: isolated scaphoid nonunion; preoperative MRI assessing the proximal fragment vascularity; and operative details of the vascularity of the proximal fragment with the tourniquet deflated. MRI results and intraoperative findings were dichotomized as either ‘yes’ or ‘no’ for the presence of vascularity. A four-fold contingency table was used to analyze the utility of preoperative MRI with 95% confidence intervals. Relative risk was calculated for subgroups to analyze the association between variables and MRI accuracy.Aims
Methods
There is ambiguity surrounding the degree of scaphoid union required to safely allow mobilization following scaphoid waist fracture. Premature mobilization could lead to refracture, but late mobilization may cause stiffness and delay return to normal function. This study aims to explore the risk of refracture at different stages of scaphoid waist fracture union in three common fracture patterns, using a novel finite element method. The most common anatomical variant of the scaphoid was modelled from a CT scan of a healthy hand and wrist using 3D Slicer freeware. This model was uploaded into COMSOL Multiphysics software to enable the application of physiological enhancements. Three common waist fracture patterns were produced following the Russe classification. Each fracture had differing stages of healing, ranging from 10% to 90% partial union, with increments of 10% union assessed. A physiological force of 100 N acting on the distal pole was applied, with the risk of refracture assessed using the Von Mises stress.Aims
Methods
Aims. The aim of this study was to determine whether closed suction drain (CSD) use influences recovery of quadriceps
Objectives. The aim of this study was to systematically review the literature on measurement of muscle
Objectives. Our objective was to predict the knee extension
Objectives. The most prevalent disorders of the shoulder are related to the
muscles of rotator cuff. In order to develop a mechanical method
for the evaluation of the rotator cuff muscles, we created a database
of isometric force generation by the rotator cuff muscles in normal
adult population. We hypothesised the existence of variations according
to age, gender and dominancy of limb. Methods. A total of 400 healthy adult volunteers were tested, classified
into groups of 50 men and women for each decade of life. Maximal
isometric force was measured at standardised positions for supraspinatus,
infraspinatus and subscapularis muscles in both shoulders in every
person. Torque of the force was calculated and normalised to lean body
mass. The profiles of mean torque-time curves for each age and gender
group were compared. Results. Our data showed that men gradually gained maximal
Concerns have been raised that deformation of
acetabular shells may disrupt the assembly process of modular prostheses.
In this study we aimed to examine the effect that the
We have compared the time to recovery of isokinetic
quadriceps
Aims. The aims of this study were to evaluate the abductor function in moderate and severe slipped capital femoral epiphysis (SCFE), comparing the results of a corrective osteotomy at the base of the femoral neck and osteoplasty with 1) in situ epiphysiodesis for mild SCFE, 2) contralateral unaffected hips, and 3) hips from healthy individuals. Patients and Methods. A total of 24 patients (mean age 14.9 years (. sd. 1.6); 17 male and seven female patients) with moderate or severe SCFE (28 hips) underwent base of neck osteotomy and osteoplasty between 2012 and 2015. In situ epiphysiodesis was performed in seven contralateral hips with mild slip. A control cohort was composed of 15 healthy individuals (mean age 16.5 years (. sd. 2.5); six male and nine female patients). The abductor function was assessed using isokinetic dynamometry and range of abduction, with a minimum one-year follow-up. Results. We found no differences in mean peak abductor torque between the hips that underwent osteotomy and those that received in situ epiphysiodesis (p = 0.63), but the torque was inferior in comparison with contralateral hips without a slip (p < 0.01) and hips from control individuals (p < 0.001). The abduction
The aim of this study was to determine the effect
of a Galeazzi fracture on the