Aims. Body exhaust suits or surgical helmet systems (colloquially, ‘space suits’) are frequently used in many forms of
Aims. To compare complication-related reoperation rates following primary
Aims. The aim of this study was to analyze the results of two radiocapitellar prostheses in a large case series followed prospectively, with medium-term follow-up. Patients and Methods. A total of 31 patients with a mean age of 54 years (27 to 73) were analyzed; nine had primary osteoarthritis (OA) and 17 had post-traumatic OA, three had capitellar osteonecrosis, and two had a fracture. Overall, 17 Lateral Resurfacing Elbow (LRE) and 14 Uni-Elbow Radio-Capitellum Implant (UNI-E)
Aim. The aim of this study was to report the long-term outcome and
implant survival of the lateral resurfacing elbow (LRE) arthroplasty
in the treatment of elbow arthritis. Patients and Methods. We reviewed a consecutive series of 27 patients (30 elbows) who
underwent LRE
Aim. The primary aim of this retrospective study was to identify the
incidence of heterotopic ossification (HO) following elective and
trauma elbow arthroplasty. The secondary aim was to determine clinical
outcomes with respect to the formation of heterotopic ossification. Patients and Methods. A total of 55 total elbow arthroplasties (TEAs) (52 patients)
performed between June 2007 and December 2015 were eligible for
inclusion in the study (29 TEAs for primary elective arthroplasty
and 26 TEAs for trauma). At review, 15 patients (17 total elbow
arthroplasties) had died from unrelated causes. There were 14 men
and 38 women with a mean age of 70 years (42 to 90). The median
clinical follow-up was 3.6 years (1.2 to 6) and the median radiological follow-up
was 3.1 years (0.5 to 7.5). Results. The overall incidence of HO was 84% (46/55). This was higher
in the trauma group (96%, 25/26) compared with the elective arthroplasty
group (72%, 21/29) (p = 0.027, Fisher’s exact test). Patients in
the trauma group had HO of higher Brooker class. The presence of
HO did not significantly affect elbow range of movement within the
trauma or elective groups (elective
Aims. In the initial development of total shoulder arthroplasty (TSA),
the humeral component was usually fixed with cement. Cementless
components were subsequently introduced. The aim of this study was
to compare the long-term outcome of cemented and cementless humeral
components in
Aims. Glenoid bone loss can be a challenging problem when revising
a shoulder arthroplasty. Precise pre-operative planning based on
plain radiographs or CT scans is essential. We have investigated
a new radiological classification system to describe the degree
of medialisation of the bony glenoid and that will indicate the
amount of bone potentially available for supporting a glenoid component.
It depends on the relationship between the most medial part of the
articular surface of the glenoid with the base of the coracoid process
and the spinoglenoid notch: it classifies the degree of bone loss
into three types. It also attempts to predict the type of glenoid reconstruction
that may be possible (impaction bone grafting, structural grafting
or simple non-augmented arthroplasty) and gives guidance about whether
a pre-operative CT scan is indicated. Patients and Methods. Inter-method reliability between plain radiographs and CT scans
was assessed retrospectively by three independent observers using
data from 39 randomly selected patients. . Inter-observer reliability and test-retest reliability was tested
on the same cohort using Cohen's kappa statistics. Correlation of
the type of glenoid with the Constant score and its pain component
was analysed using the Kruskal-Wallis method on data from 128 patients.
Anatomical studies of the scapula were reviewed to explain the findings. Results. Excellent inter-method reliability, inter-observer and test-retest
reliability were seen. The system did not correlate with the Constant
score, but correlated well with its pain component. . Take home message: Our system of classification is a helpful
guide to the degree of glenoid bone loss when embarking on revision
shoulder
The aim of this study was to evaluate the clinical and radiological
outcome of using an anatomical short-stem shoulder prosthesis to
treat primary osteoarthritis of the glenohumeral joint. A total of 66 patients (67 shoulders) with a mean age of 76 years
(63 to 92) were available for clinical and radiological follow-up
at two different timepoints (T1, mean 2.6 years, Aims
Patients and Methods
Resurfacing of the humeral head is commonly used
within the UK to treat osteoarthritis (OA) of the shoulder. We present
the results of a small prospective randomised study of this procedure
using the Global CAP prosthesis with two different coatings, Porocoat
and DuoFix hydroxyapatite (HA). We followed two groups of ten patients
with OA of the shoulder for two years after insertion of the prosthesis
with tantalum marker beads, recording pain, Constant–Murley and
American Shoulder and Elbow Surgeons (ASES) outcome scores, and
using radiostereometric analysis to assess migration. The outcomes
were similar to those of other series, with significant reductions
in pain (p = 0.003) and an improvement in the Constant (p = 0.001)
and ASES scores (p = 0.006). The mean migration of the prosthesis
three months post-operatively was 0.78 mm (0.51 to 1.69) and 0.72
mm (0.33 to 1.45) for the Porocoat and DuoFix groups, respectively.
Analysis of variance indicated that the rate of migration reached
a plateau after three months post-operatively in both groups. At
follow-up of two years the mean migration was 1 mm ( The addition of a coating of HA to the sintered surface does
not improve fixation of this prosthesis. Cite this article:
Revision total elbow arthroplasty (TEA) is often challenging.
The aim of this study was to report on the clinical and radiological
results of revision arthroplasty of the elbow with the Latitude
TEA. Between 2006 and 2010 we used the Latitude TEA for revision in
18 consecutive elbows (17 patients); mean age 53 years (28 to 80);
14 women. A Kudo TEA was revised in 15 elbows and a Souter-Strathclyde
TEA in three. Stability, range of movement (ROM), visual analogue score (VAS)
for pain and functional scores, Elbow Functional Assessment Scale
(EFAS), the Functional Rating Index of Broberg and Morrey (FRIBM)
and the Modified Andrews’ Elbow Scoring System (MAESS) were assessed
pre-operatively and at each post-operative follow-up visit (six,
12 months and biennially thereafter). Radiographs were analysed
for loosening, fractures and dislocation. The mean follow-up was
59 months (26 to 89).Aims
Patients and Methods
Aims. The liner design is a key determinant of the constraint of a reverse total shoulder arthroplasty (rTSA). The aim of this study was to compare the degree of constraint of rTSA liners between different implant systems. Methods. An implant company’s independent 3D shoulder arthroplasty planning software (mediCAD 3D shoulder v. 7.0, module v. 2.1.84.173.43) was used to determine the jump height of standard and constrained liners of different sizes (radius of curvature) of all available companies. The obtained parameters were used to calculate the stability ratio (degree of constraint) and angle of coverage (degree of glenosphere coverage by liner) of the different systems. Measurements were independently performed by two raters, and intraclass correlation coefficients were calculated to perform a reliability analysis. Additionally, measurements were compared with parameters provided by the companies themselves, when available, to ensure validity of the software-derived measurements. Results. There were variations in jump height between rTSA systems at a given size, resulting in large differences in stability ratio between systems. Standard liners exhibited a stability ratio range from 126% to 214% (mean 158% (SD 23%)) and constrained liners a range from 151% to 479% (mean 245% (SD 76%)). The angle of coverage showed a range from 103° to 130° (mean 115° (SD 7°)) for standard and a range from 113° to 156° (mean 133° (SD 11°)) for constrained liners. Four
Aims. Reconstruction after osteoarticular resection of the proximal ulna for tumours is technically difficult and little has been written about the options that are available. We report a series of four patients who underwent radial neck to humeral trochlea transposition
Aims. Arthroplasties of the elbow, including total elbow arthroplasty, radial head arthroplasty, distal humeral hemiarthroplasty, and radiocapitellar
A review of the literature on elbow replacement found no consistency in the clinical outcome measures which are used to assess the effectiveness of interventions. The aim of this study was to define core outcome domains for elbow replacement. A real-time Delphi survey was conducted over four weeks using outcomes from a scoping review of 362 studies on elbow replacement published between January 1990 and February 2021. A total of 583 outcome descriptors were rationalized to 139 unique outcomes. The survey consisted of 139 outcomes divided into 18 domains. The readability and clarity of the survey was determined by an advisory group including a patient representative. Participants were able to view aggregated responses from other participants in real time and to revisit their responses as many times as they wished during the study period. Participants were able to propose additional items for inclusion. A Patient and Public Inclusion and Engagement (PPIE) panel considered the consensus findings.Aims
Methods
Shoulder arthroplasty is effective in the management of end-stage glenohumeral joint arthritis. However, it is major surgery and patients must balance multiple factors when considering the procedure. An understanding of patients’ decision-making processes may facilitate greater support of those considering shoulder arthroplasty and inform the outcomes of future research. Participants were recruited from waiting lists of three consultant upper limb surgeons across two NHS hospitals. Semi-structured interviews were conducted with 12 participants who were awaiting elective shoulder arthroplasty. Transcribed interviews were analyzed using a grounded theory approach. Systematic coding was performed; initial codes were categorized and further developed into summary narratives through a process of discussion and refinement. Data collection and analyses continued until thematic saturation was reached.Aims
Methods
Metal and ceramic humeral head bearing surfaces are available choices in anatomical shoulder arthroplasties. Wear studies have shown superior performance of ceramic heads, however comparison of clinical outcomes according to bearing surface in total shoulder arthroplasty (TSA) and hemiarthroplasty (HA) is limited. This study aimed to compare the rates of revision and reoperation following metal and ceramic humeral head TSA and HA using data from the National Joint Registry (NJR), which collects data from England, Wales, Northern Ireland, Isle of Man and the States of Guernsey. NJR shoulder arthroplasty records were linked to Hospital Episode Statistics and the National Mortality Register. TSA and HA performed for osteoarthritis (OA) in patients with an intact rotator cuff were included. Metal and ceramic humeral head prostheses were matched within separate TSA and HA groups using propensity scores based on 12 and 11 characteristics, respectively. The primary outcome was time to first revision and the secondary outcome was non-revision reoperation.Aims
Methods
The aim of this study is to report the implant survival and factors associated with revision of total elbow arthroplasty (TEA) using data from the Dutch national registry. All TEAs recorded in the Dutch national registry between 2014 and 2020 were included. The Kaplan-Meier method was used for survival analysis, and a logistic regression model was used to assess the factors associated with revision.Aims
Methods
Aims. The aim of this study was to investigate the effects of preoperative bisphosphonate treatment on the intra- and postoperative outcomes of
The aim of this study is to evaluate the change in incidence rate of shoulder arthroplasty, indications, and surgeon volume trends associated with these procedures between January 2003 and April 2021 in the province of Nova Scotia, Canada. A total of 1,545 patients between 2005 and 2021 were analyzed. Patients operated on between 2003 and 2004 were excluded due to a lack of electronic records. Overall, 84.1% of the surgeries (n = 1,299) were performed by two fellowship-trained upper limb surgeons, with the remainder performed by one of the 14 orthopaedic surgeons working in the province.Aims
Methods
Reverse total shoulder arthroplasty (rTSA) can be used in complex cases when the glenoid requires reconstruction. In this study, a baseplate with composite bone autograft and a central trabecular titanium peg was implanted, and its migration was assessed for two years postoperatively using radiostereometric analysis (RSA). A total of 14 patients who underwent a rTSA with an autograft consented to participate. Of these, 11 had a primary rTSA using humeral head autograft and three had a revision rTSA with autograft harvested from the iliac crest. The mean age of the patients was 66 years (39 to 81). Tantalum beads were implanted in the scapula around the glenoid. RSA imaging (stereographic radiographs) was undertaken immediately postoperatively and at three, six, 12, and 24 months. Analysis was completed using model-based RSA software. Outcomes were collected preoperatively and at two years postoperatively, including the Oxford Shoulder Score, the American Shoulder and Elbow Score, and a visual analogue score for pain. A Constant score was also obtained for the assessment of strength and range of motion.Aims
Methods