Advertisement for orthosearch.org.uk
Results 1 - 20 of 97
Results per page:

Objectives. Bioresorbable orthopaedic devices with calcium phosphate (CaP) fillers are commercially available on the assumption that increased calcium (Ca) locally drives new bone formation, but the clinical benefits are unknown. Electron beam (EB) irradiation of polymer devices has been shown to enhance the release of Ca. The aims of this study were to: 1) establish the biological safety of EB surface-modified bioresorbable devices; 2) test the release kinetics of CaP from a polymer device; and 3) establish any subsequent beneficial effects on bone repair in vivo. Methods. ActivaScrew Interference (Bioretec Ltd, Tampere, Finland) and poly(L-lactide-co-glycolide) (PLGA) orthopaedic screws containing 10 wt% β-tricalcium phosphate (β-TCP) underwent EB treatment. In vitro degradation over 36 weeks was investigated by recording mass loss, pH change, and Ca release. Implant performance was investigated in vivo over 36 weeks using a lapine femoral condyle model. Bone growth and osteoclast activity were assessed by histology and enzyme histochemistry. Results. Calcium release doubled in the EB-treated group before returning to a level seen in untreated samples at 28 weeks. Extensive bone growth was observed around the perimeter of all implant types, along with limited osteoclastic activity. No statistically significant differences between comparative groups was identified. Conclusion. The higher than normal dose of EB used for surface modification did not adversely affect tissue response around implants in vivo. Surprisingly, incorporation of β-TCP and the subsequent accelerated release of Ca had no significant effect on in vivo implant performance, calling into question the clinical evidence base for these commercially available devices. Cite this article: I. Palmer, S. A. Clarke, F. J Buchanan. Enhanced release of calcium phosphate additives from bioresorbable orthopaedic devices using irradiation technology is non-beneficial in a rabbit model: An animal study. Bone Joint Res 2019;8:266–274. DOI: 10.1302/2046-3758.86.BJR-2018-0224.R2


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 2 | Pages 238 - 239
1 Mar 2003
Welkerling H Raith J Kastner N Marschall C Windhager R

A prospective single-cohort study was designed to include 20 patients with enchondromas but was stopped because of poor early results. Four patients with an enchondroma, three in the proximal humerus and one in the distal femur, were treated by curettage and filling of the defect with Norian SRS cement. Clinical and radiological follow-up including CT and MRI was carried out for 18 months. All three patients with lesions in the proximal humerus had severe pain and limited movement of the shoulder. The radiological and CT appearances of the cement were unchanged at follow-up. There were characteristic appearances of synovitis and periosteitis on MRI in two patients. Since the cement induces a soft-tissue reaction the bony cavity should be sealed with the curetted and burred bone after curettage and introduction of Norian cement, especially in sites where a tourniquet cannot be applied.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 9 | Pages 1203 - 1209
1 Sep 2005
Mattsson P Alberts A Dahlberg G Sohlman M Hyldahl HC Larsson S

We undertook a multicentre, prospective study of a series of 112 unstable trochanteric fractures in order to evaluate if internal fixation with a sliding screw device combined with augmentation using a calcium phosphate degradable cement (Norian SRS) could improve the clinical, functional and radiological outcome when compared with fractures treated with a sliding screw device alone. Pain, activities of daily living, health status (SF-36), the strength of the hip abductor muscles and radiological outcome were analysed. Six weeks after surgery, the patients in the augmented group had significantly lower global and functional pain scores (p < 0.003), less pain after walking 50 feet (p < 0.01), and a better return to the activities of daily living (p < 0.05). At follow-up at six weeks and six months, those in the augmented group showed a significant improvement compared with the control group in the SF-36 score. No other significant differences were found between the groups. We conclude that augmentation with calcium phosphate cement in unstable trochanteric fractures provides a modest reduction in pain and a slight improvement in the quality of life during the course of healing when compared with conventional fixation with a sliding screw device alone


Bone & Joint 360
Vol. 1, Issue 2 | Pages 30 - 32
1 Apr 2012

The April 2012 Research Roundup. 360 . looks at who is capable of being an arthroscopist, bupivacaine, triamcinolone and chondrotoxicity, reducing scarring in injured skeletal muscle, horny Goat Weed and the repair of osseous defects, platelet-derived growth factor and fracture healing, the importance of the reserve zone in a child’s growth plate, coping with advanced arthritis, hydroxyapatite and platelet-rich plasma for bone defects, and calcium phosphate and bone regeneration


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 6 - 9
1 Jan 2016
Fillingham Y Jacobs J

The continual cycle of bone formation and resorption is carried out by osteoblasts, osteocytes, and osteoclasts under the direction of the bone-signaling pathway. In certain situations the host cycle of bone repair is insufficient and requires the assistance of bone grafts and their substitutes. The fundamental properties of a bone graft are osteoconduction, osteoinduction, osteogenesis, and structural support. Options for bone grafting include autogenous and allograft bone and the various isolated or combined substitutes of calcium sulphate, calcium phosphate, tricalcium phosphate, and coralline hydroxyapatite. Not all bone grafts will have the same properties. As a result, understanding the requirements of the clinical situation and specific properties of the various types of bone grafts is necessary to identify the ideal graft. We present a review of the bone repair process and properties of bone grafts and their substitutes to help guide the clinician in the decision making process. Cite this article: Bone Joint J 2016;98-B(1 Suppl A):6–9


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 4 | Pages 645 - 649
1 Jul 1993
Hardy Conlan D Hay S Gregg P

The changes in serum adjusted ionised calcium and parathyroid hormone (PTH) were prospectively studied in 32 patients with isolated tibial fractures, treated conservatively. We measured serum albumin, adjusted total calcium, phosphate, pH, adjusted ionised calcium and PTH at intervals until the fractures had healed. The mean ionised calcium adjusted for pH fell within 24 hours of injury, and then rose to a peak at between four and six weeks. These changes cannot be explained by changes in serum pH or PTH. The restoration of normal ionised calcium levels after fracture coincided with the period when the callus was being calcified. Analysis of the changes in ionised calcium, phosphate and PTH suggests that PTH levels alter in response to changes in ionised calcium levels. PTH is highest immediately after fracture and lowest, often not recordable, at six weeks. The cause of the changes in the ionised calcium level has yet to be elucidated


The Journal of Bone & Joint Surgery British Volume
Vol. 50-B, Issue 3 | Pages 644 - 652
1 Aug 1968
Vizkelety T Aszodi K

1. A case of symmetrical bilateral calcareous bursitis at the elbow is described. 2. Metabolic and neurotrophic factors played a role in its genesis. 3. Chemical analysis showed a similarity between the ratio of calcium phosphate and calcium carbonate in dystrophic calcification and in the fluid in the bursal cavity. 4. An inflammatory reaction was seen around the calcium appearing interstitially: this was probably not a consequence of chemical stimuli


The Journal of Bone & Joint Surgery British Volume
Vol. 37-B, Issue 2 | Pages 304 - 323
1 May 1955
Duthie RB Barker AN

1. A method is described of demonstrating in vivo the utilisation of radioactive sulphur. 35. and of radioactive phosphorus. 32. during bone growth and repair. 2. The relationship between labelled chondroitin sulphuric acid and labelled phosphate complexes has been studied, the importance and significance of vascularity and the localisation of the enzyme alkaline phosphatase being noted. 3. It was found that bone growth by external accretion, both epiphysial and periosteal, was accompanied by an increased utilisation of radioactive chondroitin sulphuric acid and calcium phosphate complexes. 4. During repair in a fracture site, although there was deposition of radioactive phosphate, no preferential localisation of radioactive sulphur was observed and the possible explanations of this are discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 32-B, Issue 1 | Pages 30 - 34
1 Feb 1950
Hughes ESR

1. Three cases of localised deposition of calcium salts deep to the origin of the common extensors of the forearm with acute symptoms clinically indistinguishable from "tennis elbow" are described. 2. Reports of nine similar cases have been found in the literature. 3. It is suggested that "tennis elbow" is caused by a lesion, probably an adventitial bursa, in the tissue space between the tendon of origin of the forearm extensors and the capsule of the radio-humeral joint; and that it is the sudden precipitation of calcium phosphate at this site which causes the lesion here described. 4. Acute calcification near the elbow joint is compared with the similar calcification which may occur in the insertion of the supraspinatus tendon. 5. Operative treatment is advised


The Journal of Bone & Joint Surgery British Volume
Vol. 45-B, Issue 4 | Pages 770 - 779
1 Nov 1963
Udupa KN Prasad GC

1. The process of repair after fracture of the humerus of the growing rat has been studied by histological, histochemical and biochemical methods. 2. Both periosteal and surrounding mesenchymal cells take part in the process of repair. 3. The primary framework of collagen bridging the gap is mainly formed by the mesenchymal cells, while calcification and ossification of the framework is largely a function of the periosteum. 4. The mucopolysaccharide content rises rapidly in the first week after injury, and is followed by a rise in the collagen content during the second week. The deposition of calcium phosphate during the third and fourth weeks causes an apparent fall in the collagen content during that period. The collagen content tends to return to normal during the phase of remodelling in the fifth and sixth weeks. 5. The tensile strength of the healing bone bears a close relation to its collagen content


The Journal of Bone & Joint Surgery British Volume
Vol. 59-B, Issue 4 | Pages 458 - 464
1 Nov 1977
von der Mark K von der Mark H

The role of three genetically distinct collagen types in the formation of endochondral bone and in calcification and resorption of cartilage has been assessed. Using antibodies specific to types I, II and III collagen we have demonstrated in the embryonic chick tibia that endochondral bone formation began with deposition of type III collagen in lacunae of hypertropic chondrocytes by invading bone-marrow-derived cells. This was followed by the deposition of type I collagen, which is the collagenous constituent of endochondral osteoid. At later stages of development endochondral osteoid was found in the epiphysial growth plate in apparently intact lacunae of hypertrophic chondrocytes; this indicated that the latter might contribute to the synthesis of osteoid type I collagen. Immuno-histological staining for collagen types, and von Kossa staining for calcium phosphate on parallel sections, demonstrated that type I and type II collagen matrices were substrates for calcification. Endochondral bone (with type I collagen) was found on scaffolding of both uncalcified and calcified cartilage (with type II collagen), indicating that calcification of endochondral osteoid and of the underlying cartilage occurred independentyl. Spicules of endochondral cancellous bone of a four-week-old chick contained a core of calcified type II collagen


Bone & Joint Research
Vol. 12, Issue 9 | Pages 536 - 545
8 Sep 2023
Luo P Yuan Q Yang M Wan X Xu P

Osteoarthritis (OA) is mainly caused by ageing, strain, trauma, and congenital joint abnormalities, resulting in articular cartilage degeneration. During the pathogenesis of OA, the changes in subchondral bone (SB) are not only secondary manifestations of OA, but also an active part of the disease, and are closely associated with the severity of OA. In different stages of OA, there were microstructural changes in SB. Osteocytes, osteoblasts, and osteoclasts in SB are important in the pathogenesis of OA. The signal transduction mechanism in SB is necessary to maintain the balance of a stable phenotype, extracellular matrix (ECM) synthesis, and bone remodelling between articular cartilage and SB. An imbalance in signal transduction can lead to reduced cartilage quality and SB thickening, which leads to the progression of OA. By understanding changes in SB in OA, researchers are exploring drugs that can regulate these changes, which will help to provide new ideas for the treatment of OA.

Cite this article: Bone Joint Res 2023;12(9):536–545.


Bone & Joint Research
Vol. 11, Issue 10 | Pages 700 - 714
4 Oct 2022
Li J Cheung W Chow SK Ip M Leung SYS Wong RMY

Aims

Biofilm-related infection is a major complication that occurs in orthopaedic surgery. Various treatments are available but efficacy to eradicate infections varies significantly. A systematic review was performed to evaluate therapeutic interventions combating biofilm-related infections on in vivo animal models.

Methods

Literature research was performed on PubMed and Embase databases. Keywords used for search criteria were “bone AND biofilm”. Information on the species of the animal model, bacterial strain, evaluation of biofilm and bone infection, complications, key findings on observations, prevention, and treatment of biofilm were extracted.


Bone & Joint Open
Vol. 3, Issue 12 | Pages 991 - 997
23 Dec 2022
McPherson EJ Stavrakis AI Chowdhry M Curtin NL Dipane MV Crawford BM

Aims

Large acetabular bone defects encountered in revision total hip arthroplasty (THA) are challenging to restore. Metal constructs for structural support are combined with bone graft materials for restoration. Autograft is restricted due to limited volume, and allogenic grafts have downsides including cost, availability, and operative processing. Bone graft substitutes (BGS) are an attractive alternative if they can demonstrate positive remodelling. One potential product is a biphasic injectable mixture (Cerament) that combines a fast-resorbing material (calcium sulphate) with the highly osteoconductive material hydroxyapatite. This study reviews the application of this biomaterial in large acetabular defects.

Methods

We performed a retrospective review at a single institution of patients undergoing revision THA by a single surgeon. We identified 49 consecutive patients with large acetabular defects where the biphasic BGS was applied, with no other products added to the BGS. After placement of metallic acetabular implants, the BGS was injected into the remaining bone defects surrounding the new implants. Patients were followed and monitored for functional outcome scores, implant fixation, radiological graft site remodelling, and revision failures.


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 646 - 655
1 Jul 2024
Longo UG Gulotta LV De Salvatore S Lalli A Bandini B Giannarelli D Denaro V

Aims

Proximal humeral fractures are the third most common fracture among the elderly. Complications associated with fixation include screw perforation, varus collapse, and avascular necrosis of the humeral head. To address these challenges, various augmentation techniques to increase medial column support have been developed. There are currently no recent studies that definitively establish the superiority of augmented fixation over non-augmented implants in the surgical treatment of proximal humeral fractures. The aim of this systematic review and meta-analysis was to compare the outcomes of patients who underwent locking-plate fixation with cement augmentation or bone-graft augmentation versus those who underwent locking-plate fixation without augmentation for proximal humeral fractures.

Methods

The search was carried out according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines. Articles involving patients with complex proximal humeral fractures treated using open reduction with locking-plate fixation, with or without augmentation, were considered. A meta-analysis of comparative studies comparing locking-plate fixation with cement augmentation or with bone-graft augmentation versus locking-plate fixation without augmentation was performed.


The Bone & Joint Journal
Vol. 106-B, Issue 1 | Pages 28 - 37
1 Jan 2024
Gupta S Sadczuk D Riddoch FI Oliver WM Davidson E White TO Keating JF Scott CEH

Aims

This study aims to determine the rate of and risk factors for total knee arthroplasty (TKA) after operative management of tibial plateau fractures (TPFs) in older adults.

Methods

This is a retrospective cohort study of 182 displaced TPFs in 180 patients aged ≥ 60 years, over a 12-year period with a minimum follow-up of one year. The mean age was 70.7 years (SD 7.7; 60 to 89), and 139/180 patients (77.2%) were female. Radiological assessment consisted of fracture classification; pre-existing knee osteoarthritis (OA); reduction quality; loss of reduction; and post-traumatic OA. Fracture depression was measured on CT, and the volume of defect estimated as half an oblate spheroid. Operative management, complications, reoperations, and mortality were recorded.


Aims

Our objective was to conduct a systematic review and meta-analysis, to establish whether differences arise in clinical outcomes between autologous and synthetic bone grafts in the operative management of tibial plateau fractures.

Methods

A structured search of MEDLINE, EMBASE, the online archives of Bone & Joint Publishing, and CENTRAL databases from inception until 28 July 2021 was performed. Randomized, controlled, clinical trials that compared autologous and synthetic bone grafts in tibial plateau fractures were included. Preclinical studies, clinical studies in paediatric patients, pathological fractures, fracture nonunion, or chondral defects were excluded. Outcome data were assessed using the Risk of Bias 2 (ROB2) framework and synthesized in random-effect meta-analysis. The Preferred Reported Items for Systematic Review and Meta-Analyses guidance was followed throughout.


Bone & Joint Open
Vol. 4, Issue 7 | Pages 516 - 522
10 Jul 2023
Mereddy P Nallamilli SR Gowda VP Kasha S Godey SK Nallamilli RR GPRK R Meda VGR

Aims

Musculoskeletal infection is a devastating complication in both trauma and elective orthopaedic surgeries that can result in significant morbidity. Aim of this study was to assess the effectiveness and complications of local antibiotic impregnated dissolvable synthetic calcium sulphate beads (Stimulan Rapid Cure) in the hands of different surgeons from multiple centres in surgically managed bone and joint infections.

Methods

Between January 2019 and December 2022, 106 patients with bone and joint infections were treated by five surgeons in five hospitals. Surgical debridement and calcium sulphate bead insertion was performed for local elution of antibiotics in high concentration. In all, 100 patients were available for follow-up at regular intervals. Choice of antibiotic was tailor made for each patient in consultation with microbiologist based on the organism grown on culture and the sensitivity. In majority of our cases, we used a combination of vancomycin and culture sensitive heat stable antibiotic after a thorough debridement of the site. Primary wound closure was achieved in 99 patients and a split skin graft closure was done in one patient. Mean follow-up was 20 months (12 to 30).


The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 647 - 656
1 Jun 2022
Knudsen MB Thillemann JK Jørgensen PB Jakobsen SS Daugaard H Søballe K Stilling M

Aims

BoneMaster is a thin electrochemically applied hydroxyapatite (HA) coating for orthopaedic implants that is quickly resorbed during osseointegration. Early stabilization is a surrogacy marker of good survival of femoral stems. The hypothesis of this study was that a BoneMaster coating yields a fast early and lasting fixation of stems.

Methods

A total of 53 patients were randomized to be treated using Bi-Metric cementless femoral stems with either only a porous titanium plasma-sprayed coating (P group) or a porous titanium plasma-sprayed coating with an additional BoneMaster coating (PBM group). The patients were examined with radiostereometry until five years after surgery.


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 59 - 65
1 May 2024
Liu WKT Cheung A Fu H Chan PK Chiu KY

Aims

Isolated acetabular liner exchange with a highly crosslinked polyethylene (HXLPE) component is an option to address polyethylene wear and osteolysis following total hip arthroplasty (THA) in the presence of a well-fixed acetabular shell. The liner can be fixed either with the original locking mechanism or by being cemented within the acetabular component. Whether the method used for fixation of the HXLPE liner has any bearing on the long-term outcomes is still unclear.

Methods

Data were retrieved for all patients who underwent isolated acetabular component liner exchange surgery with a HXLPE component in our institute between August 2000 and January 2015. Patients were classified according to the fixation method used (original locking mechanism (n = 36) or cemented (n = 50)). Survival and revision rates were compared. A total of 86 revisions were performed and the mean duration of follow-up was 13 years.