Aims. Treatment for delayed
Satisfactory primary
Aims. Deep surgical site infection (SSI) is common after lower limb fracture. We compared the diagnosis of deep SSI using alternative methods of data collection and examined the agreement of clinical photography and in-person clinical assessment by the Centers for Disease Control and Prevention (CDC) criteria after lower limb fracture surgery. Methods. Data from two large, UK-based multicentre randomized controlled major trauma trials investigating SSI and
Aims. Local antibiotics are used in the surgical management of foot infection in diabetic patients. This systematic review analyzes the available evidence of the use of local antibiotic delivery systems as an adjunct to surgery. Materials and Methods. Databases were searched to identify eligible studies and 13 were identified for inclusion. Results. Overall, the quality of the studies was poor. A single trial suggested that
In 42 amputations (28 below-knee and 14 above-knee), healing of the stump was found to correlate with the pre-operative transcutaneous oxygen pressure (tcPO2) measured at the planned site of incision. Of 31 patients with a tcPO2 of 30 mmHg or more, 27 healed primarily, three had delayed healing and one failed to heal; of seven patients with values between 20 and 30 mmHg three healed primarily and four had delayed healing; and all four patients with a value below 20 mmHg had stumps which failed to heal and needed reamputation. It is concluded that a tcPO2 of 20 mmHg or more at the intended site of amputation indicates that the
We performed a prospective, blind, controlled study on wound infection after implant surgery involving 41 procedures in patients infected with the human immunodeficiency virus (HIV) and 141 in HIV-negative patients. The patients were staged clinically and the CD4 cell count determined. Wound infection was assessed using the asepsis wound score. A risk category was allocated to account for presurgical contamination. In HIV-positive patients, with no preoperative contamination, the incidence of wound infection (3.5%) was comparable with that of the HIV-negative group (5%; p = 0.396). The CD4 cell count did not affect the incidence of infection (r = 0.16). When there was preoperative contamination, the incidence of infection in HIV-positive patients increased markedly (42%) compared with that in HIV-negative patients (11%; p = 0.084). Our results show that when no contamination has occurred implant surgery may be undertaken safely in HIV-positive patients.
There are 33 million people worldwide currently infected with human immunodeficiency virus (HIV). This complex disease affects many of the processes involved in wound and fracture healing, and there is little evidence available to guide the management of open fractures in these patients. Fears of acute and delayed infection often inhibit the use of fixation, which may be the most effective way of achieving union. This study compared fixation of open fractures in HIV-positive and -negative patients in South Africa, a country with very high rates of both HIV and high-energy trauma. A total of 133 patients (33 HIV-positive) with 135 open fractures fulfilled the inclusion criteria. This cohort is three times larger than in any similar previously published study. The results suggest that HIV is not a contraindication to internal or external fixation of open fractures in this population, as HIV is not a significant risk factor for acute wound/implant infection. However, subgroup analysis of grade I open fractures in patients with advanced HIV and a low CD4 count (<
350) showed an increased risk of infection; we suggest that grade I open fractures in patients with advanced HIV should be treated by early debridement followed by fixation at an appropriate time.
We compared early post-operative rates of wound
infection in HIV-positive and -negative patients presenting with open
tibial fractures managed with surgical fixation. The wounds of 84 patients (85 fractures), 28 of whom were HIV
positive and 56 were HIV negative, were assessed for signs of infection
using the ASEPIS wound score. There were 19 women and 65 men with
a mean age of 34.8 years. A total of 57 fractures (17 HIV-positive The study does not support the hypothesis that HIV significantly
increases the rate of early wound or pin-site infection in open
tibial fractures. We would therefore suggest that a patient’s HIV
status should not alter the management of open tibial fractures
in patients who have a CD4 count >
350 cells/μl. Cite this article:
The aims of this study were to report the outcomes of patients with a complex fracture of the lower limb in the five years after they took part in the Wound Healing in Surgery for Trauma (WHIST) trial. The WHIST trial compared negative pressure wound therapy (NPWT) dressings with standard dressings applied at the end of the first operation for patients undergoing internal fixation of a complex fracture of the lower limb. Complex fractures included periarticular fractures and open fractures when the wound could be closed primarily at the end of the first debridement. A total of 1,548 patients aged ≥ 16 years completed the initial follow-up, six months after injury. In this study we report the pre-planned analysis of outcome data up to five years. Patients reported their Disability Rating Index (DRI) (0 to 100, in which 100 = total disability), and health-related quality of life, chronic pain scores and neuropathic pain scores annually, using a self-reported questionnaire. Complications, including further surgery related to the fracture, were also recorded.Aims
Methods
The December 2022 Research Roundup. 360. looks at: Halicin is effective against Staphylococcus aureus biofilms in vitro; Synovial fluid and serum neutrophil-to-lymphocyte ratio: useful in septic arthritis?; Transcutaneous oximetry and
The June 2024 Spine Roundup. 360. looks at: Intraoperative navigation increases the projected lifetime cancer risk in patients undergoing surgery for adolescent idiopathic scoliosis; Intrawound vancomycin powder reduces delayed deep surgical site infections following posterior spinal fusion for adolescent idiopathic scoliosis; Characterizing negative online reviews of spine surgeons; Proximal junctional failure after surgical instrumentation in adult spinal deformity: biomechanical assessment of proximal instrumentation stiffness; Nutritional supplementation and
Aims. The anterior cruciate ligament (ACL) is known to have a poor
Aims. The aim of this study was to explore risk factors for complications associated with dural tear (DT), including the types of DT, and the intra- and postoperative management of DT. Patients and Methods. Between 2012 and 2017, 12 171 patients with degenerative lumbar diseases underwent primary lumbar spine surgery. We investigated five categories of potential predictors: patient factors (sex, age, body mass index, and primary disease), surgical factors (surgical procedures, operative time, and estimated blood loss), types of DT (inaccessible for suturing/clipping and the presence of cauda equina/nerve root herniation), repair techniques (suturing, clipping, fibrin glue, polyethylene glycol (PEG) hydrogel, and polyglycolic acid sheet), and postoperative management (drainage duration). Postoperative complications were evaluated in terms of dural leak, prolonged bed rest, headache, nausea/vomiting, delayed
Aims. For rare cases when a tumour infiltrates into the hip joint, extra-articular resection is required to obtain a safe margin. Endoprosthetic reconstruction following tumour resection can effectively ensure local control and improve postoperative function. However, maximizing bone preservation without compromising surgical margin remains a challenge for surgeons due to the complexity of the procedure. The purpose of the current study was to report clinical outcomes of patients who underwent extra-articular resection of the hip joint using a custom-made osteotomy guide and 3D-printed endoprosthesis. Methods. We reviewed 15 patients over a five-year period (January 2017 to December 2022) who had undergone extra-articular resection of the hip joint due to malignant tumour using a custom-made osteotomy guide and 3D-printed endoprosthesis. Each of the 15 patients had a single lesion, with six originating from the acetabulum side and nine from the proximal femur. All patients had their posterior column preserved according to the surgical plan. Results. Postoperative pathological assessment revealed a negative surgical margin was achieved in all patients. At final follow-up, 13.3% (2/15) died and no recurrence occurred. The overall survival was 81.7% at five years. None of the patients showed any signs of aseptic loosening, and no
Objectives. The injured anterior cruciate ligament (ACL) is thought to exhibit an impaired healing response, and attempts at surgical repair have not been successful. Connective tissue growth factor (CTGF) is reported to be associated with
Aims. We report the medium-term outcomes of a consecutive series of 118 Zenith total ankle arthroplasties (TAAs) from a single, non-designer centre. Methods. Between December 2010 and May 2016, 118 consecutive Zenith prostheses were implanted in 114 patients. Demographic, clinical, and patient-reported outcome measures (PROMs) data were collected. The endpoint of the study was failure of the implant requiring revision of one or all of the components. Kaplan-Meier survival curves were generated with 95% confidence intervals (CIs) and the rate of failure calculated for each year. Results. Eight patients (ten ankles) died during follow-up, but none required revision. Of the surviving 106 patients (108 ankles: rheumatoid arthritis (RA), n = 15; osteoarthritis (OA), n = 93), 38 were women and 68 were men, with a mean age of 68.2 years (48 to 86) at the time of surgery. Mean follow-up was 5.1 years (2.1 to 9.0). A total of ten implants failed (8.5%), thus requiring revision. The implant survival at seven years, using revision as an endpoint, was 88.2% (95% CI 100% to 72.9%). There was a mean improvement in Manchester-Oxford Foot and Ankle Questionnaire (MOXFQ) from 85.0 to 32.8 and visual analogue scale (VAS) scores from 7.0 to 3.2, and overall satisfaction was 89%. The three commonest complications were malleolar fracture (14.4%, n = 17),
We prospectively randomised 78 patients into two groups, ‘drains’ or ‘no drains’ to assess the effectiveness of suction drains in reducing haematoma and effusion in the joint and its effect on
1. The incidence of failure of
Objectives. Nylon sutures and skin staples are used commonly in total knee arthroplasty (TKA) surgical wound closure. However, there is no study that compares the
We describe a retrospective review of the clinical and radiological parameters of 32 feet in 30 patients (10 men and 20 women) who underwent correction for malalignment of the hindfoot with a modified double arthrodesis through a medial approach. The mean follow-up was 21 months (13 to 37). Fusion was achieved in all feet at a mean of 13 weeks (6 to 30). Apart from the calcaneal pitch angle, all angular measurements improved significantly after surgery. Primary