Advertisement for orthosearch.org.uk
Results 1 - 8 of 8
Results per page:
Bone & Joint Open
Vol. 5, Issue 6 | Pages 457 - 463
2 Jun 2024
Coviello M Abate A Maccagnano G Ippolito F Nappi V Abbaticchio AM Caiaffa E Caiaffa V

Aims. Proximal femur fractures treatment can involve anterograde nailing with a single or double cephalic screw. An undesirable failure for this fixation is screw cut-out. In a single-screw nail, a tip-apex distance (TAD) greater than 25 mm has been associated with an increased risk of cut-out. The aim of the study was to examine the role of TAD as a risk factor in a cephalic double-screw nail. Methods. A retrospective study was conducted on 112 patients treated for intertrochanteric femur fracture with a double proximal screw nail (Endovis BA2; EBA2) from January to September 2021. The analyzed variables were age, sex, BMI, comorbidities, fracture type, side, time of surgery, quality of reduction, pre-existing therapy with bisphosphonate for osteoporosis, screw placement in two different views, and TAD. The last follow-up was at 12 months. Logistic regression was used to study the potential factors of screw cut-out, and receiver operating characteristic curve to identify the threshold value. Results. A total of 98 of the 112 patients met the inclusion criteria. Overall, 65 patients were female (66.3%), the mean age was 83.23 years (SD 7.07), and the mean follow-up was 378 days (SD 36). Cut-out was observed in five patients (5.10%). The variables identified by univariate analysis with p < 0.05 were included in the multivariate logistic regression model were screw placement and TAD. The TAD was significant with an odds ratio (OR) 5.03 (p = 0.012) as the screw placement with an OR 4.35 (p = 0.043) in the anteroposterior view, and OR 10.61 (p = 0.037) in the lateral view. The TAD threshold value identified was 29.50 mm. Conclusion. Our study confirmed the risk factors for cut-out in the double-screw nail are comparable to those in the single screw. We found a TAD value of 29.50 mm to be associated with a risk of cut-out in double-screw nails, when good fracture reduction is granted. This value is higher than the one reported with single-screw nails. Therefore, we suggest the role of TAD should be reconsidered in well-reduced fractures treated with double-screw intramedullary nail. Cite this article: Bone Jt Open 2024;5(6):457–463


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 6 | Pages 969 - 971
1 Nov 1997
Baumgaertner MR Solberg BD

We compared the results of the surgical treatment of trochanteric hip fractures before and after surgeons had been introduced to the tip-apex distance (TAD) as a method of evaluating screw position. There were 198 fractures evaluated retrospectively and 118 after instruction. The TAD is the sum of the distance from the tip of the screw to the apex of the femoral head on antero-posterior and lateral views. This decreased from a mean of 25 mm in the control group to 20 mm in the study group (p = 0.0001). The number of mechanical failures by cut-out of the screw from the head decreased from 16 (8%) in the control group at a mean of 13 months to none in the study group at a mean of eight months (p = 0.0015). There were significantly fewer poor reductions in the study group. Our study confirms the importance of good surgical technique in the treatment of trochanteric fractures and supports the concept of the TAD as a clinically useful way of describing the position of the screw


Bone & Joint Open
Vol. 4, Issue 8 | Pages 602 - 611
21 Aug 2023
James HK Pattison GTR Griffin J Fisher JD Griffin DR

Aims

To evaluate if, for orthopaedic trainees, additional cadaveric simulation training or standard training alone yields superior radiological and clinical outcomes in patients undergoing dynamic hip screw (DHS) fixation or hemiarthroplasty for hip fracture.

Methods

This was a preliminary, pragmatic, multicentre, parallel group randomized controlled trial in nine secondary and tertiary NHS hospitals in England. Researchers were blinded to group allocation. Overall, 40 trainees in the West Midlands were eligible: 33 agreed to take part and were randomized, five withdrew after randomization, 13 were allocated cadaveric training, and 15 were allocated standard training. The intervention was an additional two-day cadaveric simulation course. The control group received standard on-the-job training. Primary outcome was implant position on the postoperative radiograph: tip-apex distance (mm) (DHS) and leg length discrepancy (mm) (hemiarthroplasty). Secondary clinical outcomes were procedure time, length of hospital stay, acute postoperative complication rate, and 12-month mortality. Procedure-specific secondary outcomes were intraoperative radiation dose (for DHS) and postoperative blood transfusion requirement (hemiarthroplasty).


Bone & Joint Open
Vol. 5, Issue 1 | Pages 37 - 45
19 Jan 2024
Alm CE Karlsten A Madsen JE Nordsletten L Brattgjerd JE Pripp AH Frihagen F Röhrl SM

Aims

Despite limited clinical scientific backing, an additional trochanteric stabilizing plate (TSP) has been advocated when treating unstable trochanteric fractures with a sliding hip screw (SHS). We aimed to explore whether the TSP would result in less post operative fracture motion, compared to SHS alone.

Methods

Overall, 31 patients with AO/OTA 31-A2 trochanteric fractures were randomized to either a SHS alone or a SHS with an additional TSP. To compare postoperative fracture motion, radiostereometric analysis (RSA) was performed before and after weightbearing, and then at four, eight, 12, 26, and 52 weeks. With the “after weightbearing” images as baseline, we calculated translations and rotations, including shortening and medialization of the femoral shaft.


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 398 - 404
1 Mar 2015
Fang C Lau TW Wong TM Lee HL Leung F

The spiral blade modification of the Dynamic Hip Screw (DHS) was designed for superior biomechanical fixation in the osteoporotic femoral head. Our objective was to compare clinical outcomes and in particular the incidence of loss of fixation.

In a series of 197 consecutive patients over the age of 50 years treated with DHS-blades (blades) and 242 patients treated with conventional DHS (screw) for AO/OTA 31.A1 or A2 intertrochanteric fractures were identified from a prospectively compiled database in a level 1 trauma centre. Using propensity score matching, two groups comprising 177 matched patients were compiled and radiological and clinical outcomes compared. In each group there were 66 males and 111 females. Mean age was 83.6 (54 to 100) for the conventional DHS group and 83.8 (52 to 101) for the blade group.

Loss of fixation occurred in two blades and 13 DHSs. None of the blades had observable migration while nine DHSs had gross migration within the femoral head before the fracture healed. There were two versus four implant cut-outs respectively and one side plate pull-out in the DHS group. There was no significant difference in mortality and eventual walking ability between the groups. Multiple logistic regression suggested that poor reduction (odds ratio (OR) 11.49, 95% confidence intervals (CI) 1.45 to 90.9, p = 0.021) and fixation by DHS (OR 15.85, 95%CI 2.50 to 100.3, p = 0.003) were independent predictors of loss of fixation.

The spiral blade design may decrease the risk of implant migration in the femoral head but does not reduce the incidence of cut-out and reoperation. Reduction of the fracture is of paramount importance since poor reduction was an independent predictor for loss of fixation regardless of the implant being used.

Cite this article: Bone Joint J 2015;97-B:398–404.


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 825 - 830
1 Jun 2013
Abram SGF Pollard TCB Andrade AJMD

The Gamma nail is frequently used in unstable peri-trochanteric hip fractures. We hypothesised that mechanical failure of the Gamma nail was associated with inadequate proximal three-point fixation. We identified a consecutive series of 299 Gamma nails implanted in 299 patients over a five-year period, 223 of whom fulfilled our inclusion criteria for investigation. The series included 61 men and 162 women with a mean age of 81 years (20 to 101). Their fractures were classified according to the Modified Evans’ classification and the quality of fracture reduction was graded. The technical adequacy of three points of proximal fixation was recorded from intra-operative fluoroscopic images, and technical inadequacy for each point was defined. All patients were followed to final follow-up and mechanical failures were identified. A multivariate statistical analysis was performed, adjusting for confounders. A total of 16 failures (7.2%) were identified. The position of the lag screw relative to the lateral cortex was the most important point of proximal fixation, and when inadequate the failure rate was 25.8% (eight of 31: odds ratio 7.5 (95% confidence interval 2.5 to 22.7), p < 0.001).

Mechanical failure of the Gamma nail in peri-trochanteric femoral fractures is rare (< 1%) when three-point proximal fixation is achieved. However, when proximal fixation is inadequate, failure rates increase. The strongest predictor of failure is positioning the lateral end of the lag screw short of the lateral cortex. Adherence to simple technical points minimises the risk of fixation failure in this vulnerable patient group.

Cite this article: Bone Joint J 2013;95-B:825–30.


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1134 - 1138
1 Aug 2013
Hsu C Shih C Wang C Huang K

Although the importance of lateral femoral wall integrity is increasingly being recognised in the treatment of intertrochanteric fracture, little attention has been put on the development of a secondary post-operative fracture of the lateral wall. Patients with post-operative fractures of the lateral wall were reported to have high rates of re-operation and complication. To date, no predictors of post-operative lateral wall fracture have been reported. In this study, we investigated the reliability of lateral wall thickness as a predictor of lateral wall fracture after dynamic hip screw (DHS) implantation.

A total of 208 patients with AO/OTA 31-A1 and -A2 classified intertrochanteric fractures who received internal fixation with a DHS between January 2003 and May 2012 were reviewed. There were 103 men and 150 women with a mean age at operation of 78 years (33 to 94). The mean follow-up was 23 months (6 to 83). The right side was affected in 97 patients and the left side in 111. Clinical information including age, gender, side, fracture classification, tip–apex distance, follow-up time, lateral wall thickness and outcome were recorded and used in the statistical analysis.

Fracture classification and lateral wall thickness significantly contributed to post-operative lateral wall fracture (both p < 0.001). The lateral wall thickness threshold value for risk of developing a secondary lateral wall fracture was found to be 20.5 mm.

To our knowledge, this is the first study to investigate the risk factors of post-operative lateral wall fracture in intertrochanteric fracture. We found that lateral wall thickness was a reliable predictor of post-operative lateral wall fracture and conclude that intertrochanteric fractures with a lateral wall thickness < 20.5 mm should not be treated with DHS alone.

Cite this article: Bone Joint J 2013;95-B:1134–8.


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 391 - 397
1 Mar 2015
van Embden D Stollenwerck GANL Koster LA Kaptein BL Nelissen RGHH Schipper IB

The aim of this study was to quantify the stability of fracture-implant complex in fractures after fixation. A total of 15 patients with an undisplaced fracture of the femoral neck, treated with either a dynamic hip screw or three cannulated hip screws, and 16 patients with an AO31-A2 trochanteric fracture treated with a dynamic hip screw or a Gamma Nail, were included. Radiostereometric analysis was used at six weeks, four months and 12 months post-operatively to evaluate shortening and rotation.

Migration could be assessed in ten patients with a fracture of the femoral neck and seven with a trochanteric fracture. By four months post-operatively, a mean shortening of 5.4 mm (-0.04 to 16.1) had occurred in the fracture of the femoral neck group and 5.0 mm (-0.13 to 12.9) in the trochanteric fracture group. A wide range of rotation occurred in both types of fracture. Right-sided trochanteric fractures seem more rotationally stable than left-sided fractures.

This prospective study shows that migration at the fracture site occurs continuously during the first four post-operative months, after which stabilisation occurs. This information may allow the early recognition of patients at risk of failure of fixation.

Cite this article: Bone Joint J 2015;97-B:391–7.