Advertisement for orthosearch.org.uk
Results 1 - 20 of 428
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 311 - 320
1 Mar 2022
Cheok T Smith T Siddiquee S Jennings MP Jayasekera N Jaarsma RL

Aims. The preoperative diagnosis of periprosthetic joint infection (PJI) remains a challenge due to a lack of biomarkers that are both sensitive and specific. We investigated the performance characteristics of polymerase chain reaction (PCR), interleukin-6 (IL6), and calprotectin of synovial fluid in the diagnosis of PJI. Methods. We performed systematic search of PubMed, Embase, The Cochrane Library, Web of Science, and Science Direct from the date of inception of each database through to 31 May 2021. Studies which described the diagnostic accuracy of synovial fluid PCR, IL6, and calprotectin using the Musculoskeletal Infection Society criteria as the reference standard were identified. Results. Overall, 31 studies were identified: 20 described PCR, six described IL6, and five calprotectin. The sensitivity and specificity were 0.78 (95% confidence interval (CI) 0.67 to 0.86) and 0.97 (95% CI 0.94 to 0.99), respectively, for synovial PCR;, 0.86 (95% CI 0.74 to 0.92), and 0.94 (95% CI 0.90 to 0.96), respectively, for synovial IL6; and 0.94 (95% CI 0.82 to 0.98) and 0.93 (95% CI 0.85 to 0.97), respectively, for synovial calprotectin. Likelihood ratio scattergram analyses recommended clinical utility of synovial fluid PCR and IL6 as a confirmatory test only. Synovial calprotectin had utility in the exclusion and confirmation of PJI. Conclusion. Synovial fluid PCR and IL6 had low sensitivity and high specificity in the diagnosis of PJI, and is recommended to be used as confirmatory test. In contrast, synovial fluid calprotectin had both high sensitivity and specificity with utility in both the exclusion and confirmation of PJI. We recommend use of synovial fluid calprotectin studies in the preoperative workup of PJI. Cite this article: Bone Joint J 2022;104-B(3):311–320


The Bone & Joint Journal
Vol. 104-B, Issue 9 | Pages 1047 - 1051
1 Sep 2022
Balato G Dall’Anese R Balboni F Ascione T Pezzati P Bartolini G Quercioli M Baldini A

Aims. The diagnosis of periprosthetic joint infection (PJI) continues to present a significant clinical challenge. New biomarkers have been proposed to support clinical decision-making; among them, synovial fluid alpha-defensin has gained interest. Current research methodology suggests reference methods are needed to establish solid evidence for use of the test. This prospective study aims to evaluate the diagnostic accuracy of high-performance liquid chromatography coupled with the mass spectrometry (LC-MS) method to detect alpha-defensin in synovial fluid. Methods. Between October 2017 and September 2019, we collected synovial fluid samples from patients scheduled to undergo revision surgery for painful total knee arthroplasty (TKA). The International Consensus Meeting criteria were used to classify 33 PJIs and 92 aseptic joints. LC-MS assay was performed to measure alpha-defensin in synovial fluid of all included patients. Sensitivity, specificity, positive predictive value, negative predictive value, and the area under the receiver operating characteristic curve (AUC) were calculated to define the test diagnostic accuracy. Results. The AUC was 0.99 (95% confidence interval (CI) 0.98 to 1.00). Receiver operating characteristic (ROC) analysis showed that the optimal cut-off value of synovial fluid alpha-defensin was 1.0 μg/l. The sensitivity of alpha-defensin was 100% (95% CI 96 to 100), the specificity was 97% (95% CI 90 to 98), the positive predictive value was 89.2% (95% CI 82 to 94), and negative predictive value was 100% (95% CI 96 to 100). ROC analysis demonstrated an AUC of 0.99 (95% CI 0.98 to 1.0). Conclusion. The present study confirms the utility of alpha-defensin in the synovial fluid in patients with painful TKA to select cases of PJI. Since LC-MS is still a time-consuming technology and is available in highly specialized laboratories, further translational research studies are needed to take this evidence into routine procedures and promote a new diagnostic approach. Cite this article: Bone Joint J 2022;104-B(9):1047–1051


Bone & Joint Research
Vol. 12, Issue 2 | Pages 113 - 120
1 Feb 2023
Cai Y Liang J Chen X Zhang G Jing Z Zhang R Lv L Zhang W Dang X

Aims. This study aimed to explore the diagnostic value of synovial fluid neutrophil extracellular traps (SF-NETs) in periprosthetic joint infection (PJI) diagnosis, and compare it with that of microbial culture, serum ESR and CRP, synovial white blood cell (WBC) count, and polymorphonuclear neutrophil percentage (PMN%). Methods. In a single health centre, patients with suspected PJI were enrolled from January 2013 to December 2021. The inclusion criteria were: 1) patients who were suspected to have PJI; 2) patients with complete medical records; and 3) patients from whom sufficient synovial fluid was obtained for microbial culture and NET test. Patients who received revision surgeries due to aseptic failure (AF) were selected as controls. Synovial fluid was collected for microbial culture and SF-WBC, SF-PNM%, and SF-NET detection. The receiver operating characteristic curve (ROC) of synovial NET, WBC, PMN%, and area under the curve (AUC) were obtained; the diagnostic efficacies of these diagnostic indexes were calculated and compared. Results. The levels of SF-NETs in the PJI group were significantly higher than those of the AF group. The AUC of SF-NET was 0.971 (95% confidence interval (CI) 0.903 to 0.996), the sensitivity was 93.48% (95% CI 82.10% to 98.63%), the specificity was 96.43% (95% CI 81.65% to 99.91%), the accuracy was 94.60% (95% CI 86.73% to 98.50%), the positive predictive value was 97.73%, and the negative predictive value was 90%. Further analysis showed that SF-NET could improve the diagnosis of culture-negative PJI, patients with PJI who received antibiotic treatment preoperatively, and fungal PJI. Conclusion. SF-NET is a novel and ideal synovial fluid biomarker for PJI diagnosis, which could improve PJI diagnosis greatly. Cite this article: Bone Joint Res 2023;12(2):113–120


Bone & Joint Open
Vol. 1, Issue 12 | Pages 737 - 742
1 Dec 2020
Mihalič R Zdovc J Brumat P Trebše R

Aims. Synovial fluid white blood cell (WBC) count and percentage of polymorphonuclear cells (%PMN) are elevated at periprosthetic joint infection (PJI). Leucocytes produce different interleukins (IL), including IL-6, so we hypothesized that synovial fluid IL-6 could be a more accurate predictor of PJI than synovial fluid WBC count and %PMN. The main aim of our study was to compare the predictive performance of all three diagnostic tests in the detection of PJI. Methods. Patients undergoing total hip or knee revision surgery were included. In the perioperative assessment phase, synovial fluid WBC count, %PMN, and IL-6 concentration were measured. Patients were labeled as positive or negative according to the predefined cut-off values for IL-6 and WBC count with %PMN. Intraoperative samples for microbiological and histopathological analysis were obtained. PJI was defined as the presence of sinus tract, inflammation in histopathological samples, and growth of the same microorganism in a minimum of two or more samples out of at least four taken. Results. In total, 49 joints in 48 patients (mean age 68 years (SD 10; 26 females (54%), 25 knees (51%)) were included. Of these 11 joints (22%) were infected. The synovial fluid WBC count and %PMN predicted PJI with sensitivity, specificity, accuracy, PPV, and NPV of 82%, 97%, 94%, 90%, and 95%, respectively. Synovial fluid IL-6 predicted PJI with sensitivity, specificity, accuracy, PPV, and NPV of 73%, 95%, 90%, 80%, and 92%, respectively. A comparison of predictive performance indicated a strong agreement between tests. Conclusions. Synovial fluid IL-6 is not superior to synovial fluid WBC count and %PMN in detecting PJI. Level of Evidence: Therapeutic Level II. Cite this article: Bone Jt Open 2020;1-12:737–742


Bone & Joint Research
Vol. 9, Issue 11 | Pages 789 - 797
2 Nov 2020
Seco-Calvo J Sánchez-Herráez S Casis L Valdivia A Perez-Urzelai I Gil J Echevarría E

Aims. To analyze the potential role of synovial fluid peptidase activity as a measure of disease burden and predictive biomarker of progression in knee osteoarthritis (KOA). Methods. A cross-sectional study of 39 patients (women 71.8%, men 28.2%; mean age of 72.03 years (SD 1.15) with advanced KOA (Ahlbäck grade ≥ 3 and clinical indications for arthrocentesis) recruited through the (Orthopaedic Department at the Complejo Asistencial Universitario de León, Spain (CAULE)), measuring synovial fluid levels of puromycin-sensitive aminopeptidase (PSA), neutral aminopeptidase (NAP), aminopeptidase B (APB), prolyl endopeptidase (PEP), aspartate aminopeptidase (ASP), glutamyl aminopeptidase (GLU) and pyroglutamyl aminopeptidase (PGAP). Results. Synovial fluid peptidase activity varied significantly as a function of clinical signs, with differences in levels of PEP (p = 0.020), ASP (p < 0.001), and PGAP (p = 0. 003) associated with knee locking, PEP (p = 0.006), ASP (p = 0.001), GLU (p = 0.037), and PGAP (p = 0.000) with knee failure, and PEP (p = 0.006), ASP (p = 0.001), GLU (p = 0.037), and PGAP (p < 0.001) with knee effusion. Further, patients with the greatest functional impairment had significantly higher levels of APB (p = 0.005), PEP (p = 0.005), ASP (p = 0.006), GLU (p = 0.020), and PGAP (p < 0.001) activity, though not of NAP or PSA, indicating local alterations in the renin-angiotensin system. A binary logistic regression model showed that PSA was protective (p = 0.005; Exp (B) 0.949), whereas PEP (p = 0.005) and GLU were risk factors (p = 0.012). Conclusion. These results suggest synovial fluid peptidase activity could play a role as a measure of disease burden and predictive biomarker of progression in KOA. Cite this article: Bone Joint Res 2020;9(11):789–797


Bone & Joint Research
Vol. 9, Issue 7 | Pages 440 - 449
1 Jul 2020
Huang Z Li W Lee G Fang X Xing L Yang B Lin J Zhang W

Aims. The aim of this study was to evaluate the performance of metagenomic next-generation sequencing (mNGS) in detecting pathogens from synovial fluid of prosthetic joint infection (PJI) patients. Methods. A group of 75 patients who underwent revision knee or hip arthroplasties were enrolled prospectively. Ten patients with primary arthroplasties were included as negative controls. Synovial fluid was collected for mNGS analysis. Optimal thresholds were determined to distinguish pathogens from background microbes. Synovial fluid, tissue, and sonicate fluid were obtained for culture. Results. A total of 49 PJI and 21 noninfection patients were finally included. Of the 39 culture-positive PJI cases, mNGS results were positive in 37 patients (94.9%), and were consistent with culture results at the genus level in 32 patients (86.5%) and at the species level in 27 patients (73.0%). Metagenomic next-generation sequencing additionally identified 15 pathogens from five culture-positive and all ten culture-negative PJI cases, and even one pathogen from one noninfection patient, while yielding no positive findings in any primary arthroplasty. However, seven pathogens identified by culture were missed by mNGS. The sensitivity of mNGS for diagnosing PJI was 95.9%, which was significantly higher than that of comprehensive culture (79.6%; p = 0.014). The specificity is similar between mNGS and comprehensive culture (95.2% and 95.2%, respectively; p = 1.0). Conclusion. Metagenomic next-generation sequencing can effectively identify pathogens from synovial fluid of PJI patients, and demonstrates high accuracy in diagnosing PJI. Cite this article: Bone Joint Res 2020;9(7):440–449


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 463 - 469
1 Apr 2020
Qin L Hu N Li X Chen Y Wang J Huang W

Aims. Prosthetic joint infection (PJI) remains a major clinical challenge. Neutrophil CD64 index, Fc-gamma receptor 1 (FcγR1), plays an important role in mediating inflammation of bacterial infections and therefore could be a valuable biomarker for PJI. The aim of this study is to compare the neutrophil CD64 index in synovial and blood diagnostic ability with the standard clinical tests for discrimination PJI and aseptic implant failure. Methods. A total of 50 patients undergoing revision hip and knee arthroplasty were enrolled into a prospective study. According to Musculoskeletal Infection Society (MSIS) criteria, 25 patients were classified as infected and 25 as not infected. In all patients, neutrophil CD64 index and percentage of polymorphonuclear neutrophils (PMN%) in synovial fluid, serum CRP, ESR, and serum CD64 index levels were measured preoperatively. Receiver operating characteristic (ROC) curves and the area under the curve (AUC) were analyzed for each biomarker. Results. Serum CD64 index showed no significant difference between the two groups (p = 0.091). Synovial fluid CD64 index and PMN% discriminated good differentiation between groups of PJI and aseptic failure with AUC of 0.946 (95% confidence interval (CI) 0.842 to 0.990) and 0.938 (95% CI 0.832 to 0.987) separately. The optimal threshold value of synovial CD64 index for the diagnosis of PJI was 0.85, with a sensitivity of 92.00%, a specificity of 96.00%, and diagnostic odds ratio (DOR) of 227.11. Conclusion. The present study demonstrates that CD64 index in synovial fluid could be a promising laboratory marker for screening PJI. The cut-off values of 0.85 for synovial CD64 index has the potential to distinguish aseptic failure from PJI. Cite this article: Bone Joint J 2020;102-B(4):463–469


Bone & Joint Research
Vol. 13, Issue 11 | Pages 632 - 646
7 Nov 2024
Diaz Dilernia F Watson D Heinrichs DE Vasarhelyi E

Aims. The mechanism by which synovial fluid (SF) kills bacteria has not yet been elucidated, and a better understanding is needed. We sought to analyze the antimicrobial properties of exogenous copper in human SF against Staphylococcus aureus. Methods. We performed in vitro growth and viability assays to determine the capability of S. aureus to survive in SF with the addition of 10 µM of copper. We determined the minimum bactericidal concentration of copper (MBC-Cu) and evaluated its sensitivity to killing, comparing wild type (WT) and CopAZB-deficient USA300 strains. Results. UAMS-1 demonstrated a greater sensitivity to SF compared to USA300 WT at 12 hours (p = 0.001) and 24 hours (p = 0.027). UAMS-1 died in statistically significant quantities at 24 hours (p = 0.017), and USA300 WT survived at 24 hours. UAMS-1 was more susceptible to the addition of copper at four (p = 0.001), 12 (p = 0.005), and 24 hours (p = 0.006). We confirmed a high sensitivity to killing with the addition of exogenous copper on both strains at four (p = 0.011), 12 (p = 0.011), and 24 hours (p = 0.011). WT and CopAZB-deficient USA300 strains significantly died in SF, demonstrating a MBC-Cu of 50 µM against USA300 WT (p = 0.011). Conclusion. SF has antimicrobial properties against S. aureus, and UAMS-1 was more sensitive than USA300 WT. Adding 10 µM of copper was highly toxic, confirming its bactericidal effect. We found CopAZB proteins to be involved in copper effluxion by demonstrating the high sensitivity of mutant strains to lower copper concentrations. Thus, we propose CopAZB proteins as potential targets and use exogenous copper as a treatment alternative against S. aureus. Cite this article: Bone Joint Res 2024;13(11):632–646


Bone & Joint Research
Vol. 6, Issue 11 | Pages 612 - 618
1 Nov 2017
Yin C Suen W Lin S Wu X Li G Pan X

Objectives. This study looked to analyse the expression levels of microRNA-140-3p and microRNA-140-5p in synovial fluid, and their correlations to the severity of disease regarding knee osteoarthritis (OA). Methods. Knee joint synovial fluid samples were collected from 45 patients with OA of the knee (15 mild, 15 moderate and 15 severe), ten healthy volunteers, ten patients with gouty arthritis, and ten with rheumatoid arthritis. The Kellgren–Lawrence grading (KLG) was used to assess the radiological severity of knee OA, and the patients were stratified into mild (KLG < 2), moderate (KLG = 2), and severe (KLG > 2). The expression of miR-140-3p and miR-140-5p of individual samples was measured by SYBR Green quantitative polymerase chain reaction (PCR) analysis. The expression of miR-140-3p and miR-140-5p was normalised to U6 internal control using the 2. -△△CT. method. All data were processed using SPSS software. Results. Expression of both miR-140-3p and miR-140-5p was downregulated in OA synovial fluid, showing a statistical difference between the OA and non-OA group, and increased OA severity was associated with a decreased expression of miR-140-3p or miR-140-5p. The Spearman rank correlation analysis suggested that the expression of miR-140-3p or miR-140-5p was negatively correlated with OA severity. In addition, the expression of miR-140-5p was 7.4 times higher than that of miR-140-3p across all groups. Conclusion. The dysregulation of miR-140-3p and miR-140-5p in synovial fluid and their correlations with the disease severity of OA may provide an important experimental basis for OA classification, and the miR-140-3p/miR-140-5p are of great potential as biomarkers in the diagnosis and clinical management of patients with OA. Cite this article: C-M. Yin, W-C-W. Suen, S. Lin, X-M. Wu, G. Li, X-H. Pan. Dysregulation of both miR-140-3p and miR-140-5p in synovial fluid correlate with osteoarthritis severity. Bone Joint Res 2017;6:612–618. DOI: 10.1302/2046-3758.611.BJR-2017-0090.R1


Bone & Joint Research
Vol. 10, Issue 1 | Pages 85 - 95
27 Jan 2021
Akhbari P Jaggard MK Boulangé CL Vaghela U Graça G Bhattacharya R Lindon JC Williams HRT Gupte CM

Aims. The diagnosis of joint infections is an inexact science using combinations of blood inflammatory markers and microscopy, culture, and sensitivity of synovial fluid (SF). There is potential for small molecule metabolites in infected SF to act as infection markers that could improve accuracy and speed of detection. The objective of this study was to use nuclear magnetic resonance (NMR) spectroscopy to identify small molecule differences between infected and noninfected human SF. Methods. In all, 16 SF samples (eight infected native and prosthetic joints plus eight noninfected joints requiring arthroplasty for end-stage osteoarthritis) were collected from patients. NMR spectroscopy was used to analyze the metabolites present in each sample. Principal component analysis and univariate statistical analysis were undertaken to investigate metabolic differences between the two groups. Results. A total of 16 metabolites were found in significantly different concentrations between the groups. Three were in higher relative concentrations (lipids, cholesterol, and N-acetylated molecules) and 13 in lower relative concentrations in the infected group (citrate, glycine, glycosaminoglycans, creatinine, histidine, lysine, formate, glucose, proline, valine, dimethylsulfone, mannose, and glutamine). Conclusion. Metabolites found in significantly greater concentrations in the infected cohort are markers of inflammation and infection. They play a role in lipid metabolism and the inflammatory response. Those found in significantly reduced concentrations were involved in carbohydrate metabolism, nucleoside metabolism, the glutamate metabolic pathway, increased oxidative stress in the diseased state, and reduced articular cartilage breakdown. This is the first study to demonstrate differences in the metabolic profile of infected and noninfected human SF, using a noninfected matched cohort, and may represent putative biomarkers that form the basis of new diagnostic tests for infected SF. Cite this article: Bone Joint Res 2021;10(1):85–95


The Bone & Joint Journal
Vol. 99-B, Issue 3 | Pages 351 - 357
1 Mar 2017
Sousa R Serrano P Gomes Dias J Oliveira JC Oliveira A

Aims. The aims of this study were to increase the diagnostic accuracy of the analysis of synovial fluid in the differentiation of prosthetic joint infection (PJI) by the addition of inexpensive biomarkers such as the levels of C-reactive protein (CRP), adenosine deaminase (ADA), alpha-2-macrogloblulin (α2M) and procalcitonin. Patients and Methods. Between January 2013 and December 2015, synovial fluid and removed implants were requested from 143 revision total joint arthroplasties. A total of 55 patients met inclusion criteria of the receipt of sufficient synovial fluid, tissue samples and removed implants for analysis. The diagnosis of PJI followed the definition from a recent International Consensus Meeting to create two groups of patients; septic and aseptic. Using receiver operating characteristic curves we determined the cutoff values and diagnostic accuracy for each marker. Results. There were 23 PJIs and 32 patients with aseptic loosening. The levels of total leucocyte count, proportion of polymorphonuclear leucocytes (PMNs), CRP, ADA and α2M in the synovial fluid were all significantly higher in those with a PJI than in those with aseptic loosening. The levels of procalcitonin were comparable in the two groups. Cutoff values for the optimal performance in the diagnosis of infection were: total leucocyte count > 1463 cells/μL (sensitivity (Sens) 100%, specificity (Spec) 71.9%, positive predictive value (PPV) 71.9%, negative predictive value (NPV) 100%); proportion of PMNs > 81% (Sens 78.3%, Spec 75.0%, PPV 69.2%, NPV 82.8%); CRP > 6.7mg/L (Sens 78.3%, Spec 93.8%, PPV 90.0%, NPV 85.7%); ADA > 61U/L (Sens 78.3%, Spec 96.9%, PPV 94.7%, NPV 86.1%) and α2M > 958 mg/L (Sens 47.8%, Spec 96.9%, PPV 91.7%, NPV 72.1%). The addition of a raised level of CRP or ADA to the total leukocyte count increased the specificity: total leukocyte count > 1463 cells/μL and CRP > 6.7mg/L (Sens 78.3%, Spec 100%, PPV 100%, NPV 86.5%) or with ADA > 61U/L (Sens 78.3%, Spec 96.9%, PPV 94.7%, NPV 86.1%). . Conclusion. The total leucocyte count in the synovial fluid offers great negative predictive value in the diagnosis of PJI and the addition of more specific markers such as CRP and ADA improves the positive predictive value. Thus the addition of simple and inexpensive markers to the measurement of the leucocyte count in the synovial fluid may reduce the number of equivocal results which demand more expensive investigation. Cite this article: Bone Joint J 2017;99-B:351–7


Bone & Joint Research
Vol. 8, Issue 4 | Pages 179 - 188
1 Apr 2019
Chen M Chang C Yang L Hsieh P Shih H Ueng SWN Chang Y

Objectives. Prosthetic joint infection (PJI) diagnosis is a major challenge in orthopaedics, and no reliable parameters have been established for accurate, preoperative predictions in the differential diagnosis of aseptic loosening or PJI. This study surveyed factors in synovial fluid (SF) for improving PJI diagnosis. Methods. We enrolled 48 patients (including 39 PJI and nine aseptic loosening cases) who required knee/hip revision surgery between January 2016 and December 2017. The PJI diagnosis was established according to the Musculoskeletal Infection Society (MSIS) criteria. SF was used to survey factors by protein array and enzyme-linked immunosorbent assay to compare protein expression patterns in SF among three groups (aseptic loosening and first- and second-stage surgery). We compared routine clinical test data, such as C-reactive protein level and leucocyte number, with potential biomarker data to assess the diagnostic ability for PJI within the same patient groups. Results. Cut-off values of 1473 pg/ml, 359 pg/ml, and 8.45 pg/ml were established for interleukin (IL)-16, IL-18, and cysteine-rich with EGF-like domains 2 (CRELD2), respectively. Receiver operating characteristic curve analysis showed that these factors exhibited an accuracy of 1 as predictors of PJI. These factors represent potential biomarkers for decisions associated with prosthesis reimplantation based on their ability to return to baseline values following the completion of debridement. Conclusion. IL-16, IL-18, and CRELD2 were found to be potential biomarkers for PJI diagnosis, with SF tests outperforming blood tests in accuracy. These factors could be useful for assessing successful debridement based on their ability to return to baseline values following the completion of debridement. Cite this article: M-F. Chen, C-H. Chang, L-Y. Yang, P-H. Hsieh, H-N. Shih, S. W. N. Ueng, Y. Chang. Synovial fluid interleukin-16, interleukin-18, and CRELD2 as novel biomarkers of prosthetic joint infections. Bone Joint Res 2019;8:179–188. DOI: 10.1302/2046-3758.84.BJR-2018-0291.R1


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 288 - 296
1 Mar 2019
Sigmund IK Holinka J Sevelda F Staats K Heisinger S Kubista B McNally MA Windhager R

Aims. This study aimed to assess the performance of an automated multiplex polymerase chain reaction (mPCR) technique for rapid diagnosis of native joint septic arthritis. Patients and Methods. Consecutive patients with suspected septic arthritis undergoing aseptic diagnostic joint aspiration were included. The aspirate was used for analysis by mPCR and conventional microbiological analysis. A joint was classed as septic according to modified Newman criteria. Based on receiver operating characteristic (ROC) analysis, the area under the ROC curve (AUC) values of the mPCR and the synovial fluid culture were compared using the z-test. A total of 72 out of 76 consecutive patients (33 women, 39 men; mean age 64 years (22 to 92)) with suspected septic arthritis were included in this study. Results. Of 72 patients, 42 (58%) were deemed to have septic joints. The sensitivity of mPCR and synovial fluid culture was 38% and 29%, respectively. No significant differences were found between the AUCs of both techniques (p = 0.138). A strong concordance of 89% (Cohen’s kappa: 0.65) was shown. The mPCR failed to detect Staphylococcus aureus (n = 1) and Streptococcus pneumoniae (n = 1; no primer included in the mPCR), whereas the synovial fluid culture missed six microorganisms (positive mPCR: S. aureus (n = 2), Cutibacterium acnes (n = 3), coagulase-negative staphylococci (n = 2)). Conclusion. The automated mPCR showed at least a similar performance to the synovial fluid culture (the current benchmark) in diagnosing septic arthritis, having the great advantage of a shorter turnaround time (within five hours). Cite this article: Bone Joint J 2019;101-B:288–296


Bone & Joint Open
Vol. 2, Issue 8 | Pages 576 - 582
2 Aug 2021
Fuchs M Kirchhoff F Reichel H Perka C Faschingbauer M Gwinner C

Aims. Current guidelines consider analyses of joint aspirates, including leucocyte cell count (LC) and polymorphonuclear percentage (PMN%) as a diagnostic mainstay of periprosthetic joint infection (PJI). It is unclear if these parameters are subject to a certain degree of variability over time. Therefore, the aim of this study was to evaluate the variation of LC and PMN% in patients with aseptic revision total knee arthroplasty (TKA). Methods. We conducted a prospective, double-centre study of 40 patients with 40 knee joints. Patients underwent joint aspiration at two different time points with a maximum period of 120 days in between these interventions and without any events such as other joint aspirations or surgeries. The main indications for TKA revision surgery were aseptic implant loosening (n = 24) and joint instability (n = 11). Results. Overall, 80 synovial fluid samples of 40 patients were analyzed. The average time period between the joint aspirations was 50 days (SD 32). There was a significantly higher percentage change in LC when compared to PMN% (44.1% (SD 28.6%) vs 27.3% (SD 23.7%); p = 0.003). When applying standard definition criteria, LC counts were found to skip back and forth between the two time points with exceeding the thresholds in up to 20% of cases, which was significantly more compared to PMN% for the European Bone and Joint Infection Society (EBJIS) criteria (p = 0.001), as well as for Musculoskeletal Infection Society (MSIS) (p = 0.029). Conclusion. LC and PMN% are subject to considerable variation. According to its higher interindividual variance, LC evaluation might contribute to false-positive or false-negative results in PJI assessment. Single LC testing prior to TKA revision surgery seems to be insufficient to exclude PJI. On the basis of the obtained results, PMN% analyses overrule LC measurements with regard to a conclusive diagnostic algorithm. Cite this article: Bone Jt Open 2021;2(8):566–572


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 554 - 557
1 Apr 2013
Dinneen A Guyot A Clements J Bradley N

Cut-off values with highest sensitivity and specificity for the synovial fluid white cell and differential count will facilitate the accurate diagnosis of infection in total knee (TKR) and total hip replacement (THR). All patients undergoing revision TKR or THR for suspected prosthetic joint infection between 2009 and 2011 at two hospitals were identified. A total of 75 patients were included with a mean age of 70.3 years (38 to 89). Synovial fluid was aspirated pre-operatively and peri-prosthetic tissue samples were taken intra-operatively for histological and microbiological examination. Receiver operating characteristic (ROC) plots were constructed for white cell and differential counts in aspirated fluid. The optimal cut-off for TKR and THR was 1590 white cells/µl and 65% neutrophilia. The white cell count cut-off value identified for THR was notably lower than previously quoted in the literature. A cut-off value for white cell count in synovial aspirate in suspected prosthetic joint infection of between 1100 and 1700 white cells/µl is likely to be applicable to both THR and TKR. Cite this article: Bone Joint J 2013;95-B:554–7


The Bone & Joint Journal
Vol. 99-B, Issue 11 | Pages 1477 - 1481
1 Nov 2017
Hernandez NM Taunton MJ Perry KI Mara KC Hanssen AD Abdel MP

Aims. Patients with flexion instability after total knee arthroplasty (TKA) often present with a recurrent effusion, which may be a haemarthrosis. While the radiographic factors contributing to flexion instability have been elucidated, the clinical diagnosis remains challenging. Our aim, in this study, was to determine the mean white cell count and differential profile in pre-operative aspirations of synovial fluid in a consecutive series of patients undergoing revision TKA for flexion instability. Patients and Methods. Between 2000 and 2010, 60 patients undergoing aseptic revision TKA for flexion instability were identified. The results of the pre-operative aspiration of synovial fluid were available for 53 patients (88%). These patients were 1:2 matched to 106 patients who underwent aseptic TKA for indications other than flexion instability. The mean age of the patients at revision TKA was 65 years (44 to 82) and 55% were women. The mean follow-up was 4.3 years (2 to 10.2). Results. In the flexion instability group, the median total cell count was 312 cells/µL (interquartile range (IQR) 104 to 624), with a mean distribution of 45% macrophages (2% to 90%), 30% lymphocytes (1% to 69%), 18% neutrophils (0% to 80%), 0.5% eosinophils (0% to 6%) and 7% other cells (0% to 42%; mainly synovial cells). There was no significant difference in the median total cell count (p = 0.14) or mean distribution of macrophages (p = 0.42), lymphocytes (p = 0.38), neutrophils (p = 0.19) and eosinophils (p = 0.89) between the flexion instability and control groups. There was a significant difference in the percentage of bloody serosanguineous aspirations which was 58% in the flexion instability group and 18% in the control group (odds ratio = 6.5; p = 0.0001). Conclusions. In the group of patients who underwent revision TKA for flexion instability, most had a mean cell count and differential similar to those who underwent revision for other aseptic indications. However, bloody serosanguineous aspirations were 6.5 times more common in those with flexion instability confirming that many of the recurrent effusions seen in this condition are haemarthroses. Cite this article: Bone Joint J 2017;99-B:1477–81


The Bone & Joint Journal
Vol. 103-B, Issue 6 | Pages 1119 - 1126
1 Jun 2021
Ivy MI Sharma K Greenwood-Quaintance KE Tande AJ Osmon DR Berbari EF Mandrekar J Beauchamp CP Hanssen AD Abdel MP Lewallen DG Perry K Block DR Snyder MR Patel R

Aims. The aim of this study was to determine the diagnostic accuracy of α defensin (AD) lateral flow assay (LFA) and enzyme-linked immunosorbent assay (ELISA) tests for periprosthetic joint infection (PJI) in comparison to conventional synovial white blood cell (WBC) count and polymorphonuclear neutrophil percentage (PMN%) analysis. Methods. Patients undergoing joint aspiration for evaluation of pain after total knee arthroplasty (TKA) or total hip arthroplasty (THA) were considered for inclusion. Synovial fluids from 99 patients (25 THA and 74 TKA) were analyzed by WBC count and PMN% analysis, AD LFA, and AD ELISA. WBC and PMN% cutoffs of ≥ 1,700 cells/mm. 3. and ≥ 65% for TKA and ≥ 3,000 cells/mm. 3. and ≥ 80% for THA were used, respectively. A panel of three physicians, all with expertise in orthopaedic infections and who were blinded to the results of AD tests, independently reviewed patient data to diagnose subjects as with or without PJI. Consensus PJI classification was used as the reference standard to evaluate test performances. Results were compared using McNemar’s test and area under the receiver operating characteristic curve (AUC) analysis. Results. Expert consensus classified 18 arthroplasies as having failed due to PJI and 81 due to aseptic failure. Using these classifications, the calculated sensitivity and specificity of AD LFA was 83.3% (95% confidence interval (CI) 58.6 to 96.4) and 93.8% (95% CI 86.2 to 98.0), respectively. Sensitivity and specificity of AD ELISA was 83.3% (95% CI 58.6 to 96.4) and 96.3% (95% CI 89.6 to 99.2), respectively. There was no statistically significant difference between sensitivity (p = 1.000) or specificity (p = 0.157) of the two AD assays. AUC for AD LFA was 0.891. In comparison, AUC for synovial WBC count, PMN%, and the combination of the two values was 0.821 (sensitivity p = 1.000, specificity p < 0.001), 0.886 (sensitivity p = 0.317, specificity p = 0.011), and 0.926 (sensitivity p = 0.317, specificity p = 0.317), respectively. Conclusion. The diagnostic accuracy of synovial AD for PJI diagnosis is comparable and not statistically superior to that of synovial WBC count plus PMN% combined. Cite this article: Bone Joint J 2021;103-B(6):1119–1126


Bone & Joint Research
Vol. 9, Issue 8 | Pages 450 - 456
1 Aug 2020
Zhang Z Cai Y Bai G Zhang C Li W Yang B Zhang W

Aims. This study aimed to evaluate calprotectin in synovial fluid for diagnosing chronic prosthetic joint infection (PJI) . Methods. A total of 63 patients who were suspected of PJI were enrolled. The synovial fluid calprotectin was tested by an enzyme-linked immunosorbent assay (ELISA). Laboratory test data, such as ESR, CRP, synovial fluid white blood cells (SF-WBCs), and synovial fluid polymorphonuclear cells (SF-PMNs), were documented. Chi-squared tests were used to compare the sensitivity and specificity of calprotectin and laboratory tests. The area under the curve (AUC) of the receiver operating characteristic (ROC) curve was calculated to determine diagnostic efficacy. Results. The median calprotectin level was 776 μg/ml (interquartile range (IQR) 536.5 to 1132) in the PJI group and 54.5 μg/ml (IQR, 38.75 to 78.25) in the aseptic failure (AF) group (p < 0.05). Using a threshold of 173 ug/ml, the sensitivity was 95.2%, with a 97.6% specificity, and the AUC was 0.993. The sensitivity of calprotectin of the antibiotic-treated PJI group was 100% versus 90.9% of the non-antibiotic-treated PJI group. Although 47.6% (ten cases) of the patients in the PJI group received antibiotics before aspiration, the diagnostic efficacy of calprotectin was not affected. The sensitivity and specificity of ESR, CRP, SF-WBCs, and SF-PMNs ranged from 76.2% to 90.5% and 64.3% to 85.7%, respectively. Conclusion. Calprotectin in synovial fluid has great diagnostic efficacy for PJI diagnosisand outperformed ESR, CRP, SF-WBCs, and SF-PMNs. Cite this article: Bone Joint Res 2020;9(8):450–456


Bone & Joint Research
Vol. 9, Issue 9 | Pages 623 - 632
5 Sep 2020
Jayadev C Hulley P Swales C Snelling S Collins G Taylor P Price A

Aims. The lack of disease-modifying treatments for osteoarthritis (OA) is linked to a shortage of suitable biomarkers. This study combines multi-molecule synovial fluid analysis with machine learning to produce an accurate diagnostic biomarker model for end-stage knee OA (esOA). Methods. Synovial fluid (SF) from patients with esOA, non-OA knee injury, and inflammatory knee arthritis were analyzed for 35 potential markers using immunoassays. Partial least square discriminant analysis (PLS-DA) was used to derive a biomarker model for cohort classification. The ability of the biomarker model to diagnose esOA was validated by identical wide-spectrum SF analysis of a test cohort of ten patients with esOA. Results. PLS-DA produced a streamlined biomarker model with excellent sensitivity (95%), specificity (98.4%), and reliability (97.4%). The eight-biomarker model produced a fingerprint for esOA comprising type IIA procollagen N-terminal propeptide (PIIANP), tissue inhibitor of metalloproteinase (TIMP)-1, a disintegrin and metalloproteinase with thrombospondin motifs 4 (ADAMTS-4), monocyte chemoattractant protein (MCP)-1, interferon-γ-inducible protein-10 (IP-10), and transforming growth factor (TGF)-β3. Receiver operating characteristic (ROC) analysis demonstrated excellent discriminatory accuracy: area under the curve (AUC) being 0.970 for esOA, 0.957 for knee injury, and 1 for inflammatory arthritis. All ten validation test patients were classified correctly as esOA (accuracy 100%; reliability 100%) by the biomarker model. Conclusion. SF analysis coupled with machine learning produced a partially validated biomarker model with cohort-specific fingerprints that accurately and reliably discriminated esOA from knee injury and inflammatory arthritis with almost 100% efficacy. The presented findings and approach represent a new biomarker concept and potential diagnostic tool to stage disease in therapy trials and monitor the efficacy of such interventions. Cite this article: Bone Joint Res 2020;9(9):623–632


Bone & Joint Research
Vol. 12, Issue 9 | Pages 559 - 570
14 Sep 2023
Wang Y Li G Ji B Xu B Zhang X Maimaitiyiming A Cao L

Aims. To investigate the optimal thresholds and diagnostic efficacy of commonly used serological and synovial fluid detection indexes for diagnosing periprosthetic joint infection (PJI) in patients who have rheumatoid arthritis (RA). Methods. The data from 348 patients who had RA or osteoarthritis (OA) and had previously undergone a total knee (TKA) and/or a total hip arthroplasty (THA) (including RA-PJI: 60 cases, RA-non-PJI: 80 cases; OA-PJI: 104 cases, OA-non-PJI: 104 cases) were retrospectively analyzed. A receiver operating characteristic curve was used to determine the optimal thresholds of the CRP, ESR, synovial fluid white blood cell count (WBC), and polymorphonuclear neutrophil percentage (PMN%) for diagnosing RA-PJI and OA-PJI. The diagnostic efficacy was evaluated by comparing the area under the curve (AUC) of each index and applying the results of the combined index diagnostic test. Results. For PJI prediction, the results of serological and synovial fluid indexes were different between the RA-PJI and OA-PJI groups. The optimal cutoff value of CRP for diagnosing RA-PJI was 12.5 mg/l, ESR was 39 mm/hour, synovial fluid WBC was 3,654/μl, and PMN% was 65.9%; and those of OA-PJI were 8.2 mg/l, 31 mm/hour, 2,673/μl, and 62.0%, respectively. In the RA-PJI group, the specificity (94.4%), positive predictive value (97.1%), and AUC (0.916) of synovial fluid WBC were higher than those of the other indexes. The optimal cutoff values of synovial fluid WBC and PMN% for diagnosing RA-PJI after THA were significantly higher than those of TKA. The specificity and positive predictive value of the combined index were 100%. Conclusion. Serum inflammatory and synovial fluid indexes can be used for diagnosing RA-PJI, for which synovial fluid WBC is the best detection index. Combining multiple detection indexes can provide a reference basis for the early and accurate diagnosis of RA-PJI. Cite this article: Bone Joint Res 2023;12(9):559–570