The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 801 - 810
1 Jul 2022
Krull P Steinbrück A Grimberg AW Melsheimer O Morlock M Perka C

Aims. Registry studies on modified acetabular polyethylene (PE) liner designs are limited. We investigated the influence of standard and modified PE acetabular liner designs on the revision rate for mechanical complications in primary cementless total hip arthroplasty (THA). Methods. We analyzed 151,096 primary cementless THAs from the German Arthroplasty Registry (EPRD) between November 2012 and November 2020. Cumulative incidence of revision for mechanical complications for standard and four modified PE liners (lipped, offset, angulated/offset, and angulated) was determined using competing risk analysis at one and seven years. Confounders were investigated with a Cox proportional-hazards model. Results. Median follow-up was 868 days (interquartile range 418 to 1,364). The offset liner design reduced the risk of revision (hazard ratio (HR) 0.68 (95% confidence interval (CI) 0.50 to 0.92)), while the angulated/offset liner increased the risk of revision for mechanical failure (HR 1.81 (95% CI 1.38 to 2.36)). The cumulative incidence of revision was lowest for the offset liner at one and seven years (1.0% (95% CI 0.7 to 1.3) and 1.8% (95% CI 1.0 to 3.0)). No difference was found between standard, lipped, and angulated liner designs. Higher age at index primary THA and an Elixhauser Comorbidity Index greater than 0 increased the revision risk in the first year after surgery. Implantation of a higher proportion of a single design of liner in a hospital reduced revision risk slightly but significantly (p = 0.001). Conclusion. The use of standard acetabular component liners remains a good choice in primary uncemented THA, as most modified liner designs were not associated with a reduced risk of revision for mechanical failure. Offset liner designs were found to be beneficial and angulated/offset liner designs were associated with higher risks of revision. Cite this article: Bone Joint J 2022;104-B(7):801–810


Bone & Joint Open
Vol. 5, Issue 10 | Pages 894 - 897
16 Oct 2024
Stoneham A Poon P Hirner M Frampton C Gao R

Aims. Body exhaust suits or surgical helmet systems (colloquially, ‘space suits’) are frequently used in many forms of arthroplasty, with the aim of providing personal protection to surgeons and, perhaps, reducing periprosthetic joint infections, although this has not consistently been borne out in systematic reviews and registry studies. To date, no large-scale study has investigated whether this is applicable to shoulder arthroplasty. We used the New Zealand Joint Registry to assess whether the use of surgical helmet systems was associated with lower all-cause revision or revision for deep infection in primary shoulder arthroplasties. Methods. We analyzed 16,000 shoulder arthroplasties (hemiarthroplasties, anatomical, and reverse geometry prostheses) recorded on the New Zealand Joint Registry from its inception in 2000 to the present day. We assessed patient factors including age, BMI, sex, and American Society of Anesthesiologists (ASA) grade, as well as whether or not the operation took place in a laminar flow operating theatre. Results. A total of 2,728 operations (17%) took place using surgical helmet systems. Patient cohorts were broadly similar in terms of indication for surgery (osteoarthritis, rheumatoid arthritis, fractures) and medical comorbidities (age and sex). There were 842 revisions (5% of cases) with just 98 for deep infection (0.6% of all cases or 11.6% of the revisions). There were no differences in all-cause revisions or revision for deep infection between the surgical helmet systems and conventional gowns (p = 0.893 and p = 0.911, respectively). Conclusion. We found no evidence that wearing a surgical helmet system reduces the incidence of periprosthetic joint infection in any kind of primary shoulder arthroplasty. We acknowledge the limitations of this registry study and accept that there may be other benefits in terms of personal protection, comfort, or visibility. However, given their financial and ecological footprint, they should be used judiciously in shoulder surgery. Cite this article: Bone Jt Open 2024;5(10):894–897


Bone & Joint Open
Vol. 5, Issue 8 | Pages 644 - 651
7 Aug 2024
Hald JT Knudsen UK Petersen MM Lindberg-Larsen M El-Galaly AB Odgaard A

Aims. The aim of this study was to perform a systematic review and bias evaluation of the current literature to create an overview of risk factors for re-revision following revision total knee arthroplasty (rTKA). Methods. A systematic search of MEDLINE and Embase was completed in accordance with the Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) guidelines. The studies were required to include a population of index rTKAs. Primary or secondary outcomes had to be re-revision. The association between preoperative factors and the effect on the risk for re-revision was also required to be reported by the studies. Results. The search yielded 4,847 studies, of which 15 were included. A majority of the studies were retrospective cohorts or registry studies. In total, 26 significant risk factors for re-revision were identified. Of these, the following risk factors were consistent across multiple studies: age at the time of index revision, male sex, index revision being partial revision, and index revision due to infection. Modifiable risk factors were opioid use, BMI > 40 kg/m. 2. , and anaemia. History of one-stage revision due to infection was associated with the highest risk of re-revision. Conclusion. Overall, 26 risk factors have been associated with an increased risk of re-revision following rTKA. However, various levels of methodological bias were found in the studies. Future studies should ensure valid comparisons by including patients with identical indications and using clear definitions for accurate assessments. Cite this article: Bone Jt Open 2024;5(8):644–651


Bone & Joint Open
Vol. 3, Issue 7 | Pages 589 - 595
1 Jul 2022
Joo PY Chen AF Richards J Law TY Taylor K Marchand K Clark G Collopy D Marchand RC Roche M Mont MA Malkani AL

Aims. The aim of this study was to report patient and clinical outcomes following robotic-assisted total knee arthroplasty (RA-TKA) at multiple institutions with a minimum two-year follow-up. Methods. This was a multicentre registry study from October 2016 to June 2021 that included 861 primary RA-TKA patients who completed at least one pre- and postoperative patient-reported outcome measure (PROM) questionnaire, including Forgotten Joint Score (FJS), Knee Injury and Osteoarthritis Outcomes Score for Joint Replacement (KOOS JR), and pain out of 100 points. The mean age was 67 years (35 to 86), 452 were male (53%), mean BMI was 31.5 kg/m. 2. (19 to 58), and 553 (64%) cemented and 308 (36%) cementless implants. Results. There were significant improvements in PROMs over time between preoperative, one- to two-year, and > two-year follow-up, with a mean FJS of 17.5 (SD 18.2), 70.2 (SD 27.8), and 76.7 (SD 25.8; p < 0.001); mean KOOS JR of 51.6 (SD 11.5), 85.1 (SD 13.8), and 87.9 (SD 13.0; p < 0.001); and mean pain scores of 65.7 (SD 20.4), 13.0 (SD 19.1), and 11.3 (SD 19.9; p < 0.001), respectively. There were eight superficial infections (0.9%) and four revisions (0.5%). Conclusion. RA-TKA demonstrated consistent clinical results across multiple institutions with excellent PROMs that continued to improve over time. With the ability to achieve target alignment in the coronal, axial, and sagittal planes and provide intraoperative real-time data to obtain balanced gaps, RA-TKA demonstrated excellent clinical outcomes and PROMs in this patient population. Cite this article: Bone Jt Open 2022;3(7):589–595


Bone & Joint Open
Vol. 4, Issue 4 | Pages 234 - 240
3 Apr 2023
Poacher AT Froud JLJ Caterson J Crook DL Ramage G Marsh L Poacher G Carpenter EC

Aims. Early detection of developmental dysplasia of the hip (DDH) is associated with improved outcomes of conservative treatment. Therefore, we aimed to evaluate a novel screening programme that included both the primary risk factors of breech presentation and family history, and the secondary risk factors of oligohydramnios and foot deformities. Methods. A five-year prospective registry study investigating every live birth in the study’s catchment area (n = 27,731), all of whom underwent screening for risk factors and examination at the newborn and six- to eight-week neonatal examination and review. DDH was diagnosed using ultrasonography and the Graf classification system, defined as grade IIb or above or rapidly regressing IIa disease (≥4. o. at four weeks follow-up). Multivariate odds ratios were calculated to establish significant association, and risk differences were calculated to provide quantifiable risk increase with DDH, positive predictive value was used as a measure of predictive efficacy. The cost-effectiveness of using these risk factors to predict DDH was evaluated using NHS tariffs (January 2021). Results. The prevalence of DDH that required treatment within our population was 5/1,000 live births. The rate of missed presentation of DDH was 0.43/1000 live births. Breech position, family history, oligohydramnios, and foot deformities demonstrated significant association with DDH (p < 0.0001). The presence of breech presentation increased the risk of DDH by 1.69% (95% confidence interval (CI) 0.93% to 2.45%), family history by 3.57% (95% CI 2.06% to 5.09%), foot deformities by 8.95% (95% CI 4.81% to 13.1%), and oligohydramnios nby 11.6% (95 % CI 3.0% to 19.0%). Primary risk factors family history and breech presentation demonstrated an estimated cost-per-case detection of £6,276 and £11,409, respectively. Oligohydramnios and foot deformities demonstrated a cost-per-case detected less than the cost of primary risk factors of £2,260 and £2,670, respectively. Conclusion. The inclusion of secondary risk factors within a national screening programme was clinically successful as they were more cost and resource-efficient predictors of DDH than primary risk factors, suggesting they should be considered in the national guidance. Cite this article: Bone Jt Open 2023;4(4):234–240


The Bone & Joint Journal
Vol. 103-B, Issue 9 | Pages 1479 - 1487
1 Sep 2021
Davis ET Pagkalos J Kopjar B

Aims. The aim of our study was to investigate the effect of asymmetric crosslinked polyethylene liner use on the risk of revision of cementless and hybrid total hip arthroplasties (THAs). Methods. We undertook a registry study combining the National Joint Registry dataset with polyethylene manufacturing characteristics as supplied by the manufacturers. The primary endpoint was revision for any reason. We performed further analyses on other reasons including instability, aseptic loosening, wear, and liner dissociation. The primary analytic approach was Cox proportional hazard regression. Results. A total of 213,146 THAs were included in the analysis. Overall, 2,997 revisions were recorded, 1,569 in THAs with a flat liner and 1,428 in THAs using an asymmetric liner. Flat liner THAs had a higher risk of revision for any reason than asymmetric liner THAs when implanted through a Hardinge/anterolateral approach (hazard ratio (HR) 1.169, 95% confidence interval (CI) 1.022 to 1.337) and through a posterior approach (HR 1.122, 95% CI 1.108 to 1.346). There was no increased risk of revision for aseptic loosening when asymmetric liners were used for any surgical approach. A separate analysis of the three most frequently used crosslinked polyethylene liners was in agreement with this finding. When analyzing THAs with flat liners only, THAs implanted through a Hardinge/anterolateral approach were associated with a reduced risk of revision for instability compared to posterior approach THAs (HR 0.561 (95% CI 0.446 to 0.706)). When analyzing THAs with an asymmetric liner, there was no significant difference in the risk of revision for instability between the two approaches (HR 0.838 (95% CI 0.633 to 1.110)). Conclusion. For THAs implanted through the posterior approach, the use of asymmetric liners reduces the risk of revision for instability and revision for any reason. In THAs implanted through a Hardinge/anterolateral approach, the use of an asymmetric liner was associated with a reduced risk of revision. The effect on revision for instability was less pronounced than in the posterior approach. Cite this article: Bone Joint J 2021;103-B(9):1479–1487


Aims. To investigate the effect of polyethylene manufacturing characteristics and irradiation dose on the survival of cemented and reverse hybrid total hip arthroplasties (THAs). Methods. In this registry study, data from the National Joint Registry of England, Wales, Northern Ireland and the Isle of Man (NJR) were linked with manufacturing data supplied by manufacturers. The primary endpoint was revision of any component. Cox proportional hazard regression was a primary analytic approach adjusting for competing risk of death, patient characteristics, head composition, and stem fixation. Results. A total of 290,770 primary THAs were successfully linked with manufacturing characteristics. Overall 4,708 revisions were analyzed, 1,260 of which were due to aseptic loosening. Total radiation dose was identified as a risk factor and included in the Cox model. For statistical modelling of aseptic loosening, THAs were grouped into three categories: G1 (no radiation); G2 ( > 0 to < 5 Mrad); and G3 ( ≥ 5 Mrad). G1 had the worst survivorship. The Cox regression hazard ratio for revision due to aseptic loosening for G2 was 0.7 (95% confidence interval (CI) 0.58 to 0.83), and for G3 0.4 (95% CI 0.30 to 0.53). Male sex and uncemented stem fixation were associated with higher risk of revision and ceramic heads with lower risk. Conclusion. Polyethylene irradiation was associated with reduced risk of revision for aseptic loosening. Radiation doses of ≥ 5 Mrad were associated with a further reduction in risk. Cite this article: Bone Joint Res 2020;9(9):563–571


The Bone & Joint Journal
Vol. 102-B, Issue 3 | Pages 319 - 328
1 Mar 2020
St Mart J de Steiger RN Cuthbert A Donnelly W

Aim. There has been a significant reduction in unicompartmental knee arthroplasty (UKA) procedures recorded in Australia. This follows several national joint registry studies documenting high UKA revision rates when compared to total knee arthroplasty (TKA). With the recent introduction of robotically assisted UKA procedures, it is hoped that outcomes improve. This study examines the cumulative revision rate of UKA procedures implanted with a newly introduced robotic system and compares the results to one of the best performing non-robotically assisted UKA prostheses, as well as all other non-robotically assisted UKA procedures. Methods. Data from the Australian Orthopaedic Association National Joint Arthroplasty Registry (AOANJRR) for all UKA procedures performed for osteoarthritis (OA) between 2015 and 2018 were analyzed. Procedures using the Restoris MCK UKA prosthesis implanted using the Mako Robotic-Arm Assisted System were compared to non-robotically assisted Zimmer Unicompartmental High Flex Knee System (ZUK) UKA, a commonly used UKA with previously reported good outcomes and to all other non-robotically assisted UKA procedures using Cox proportional hazard ratios (HRs) and Kaplan-Meier estimates of survivorship. Results. There was no difference in the rate of revision when the Mako-assisted Restoris UKA was compared to the ZUK UKA (zero to nine months: HR 1.14 (95% CI 0.71 to 1.83; p = 0.596) vs nine months and over: HR 0.66 (95% CI 0.42 to 1.02; p = 0.058)). The Mako-assisted Restoris had a significantly lower overall revision rate compared to the other types of non-robotically assisted procedures (HR 0.58 (95% confidence interval (CI) 0.42 to 0.79); p < 0.001) at three years. Revision for aseptic loosening was lower for the Mako-assisted Restoris compared to all other non-robotically assisted UKA (entire period: HR 0.34 (95% CI 0.17 to 0.65); p = 0.001), but not the ZUK prosthesis. However, revision for infection was significantly higher for the Mako-assisted Restoris compared to the two comparator groups (ZUK: entire period: HR 2.91 (95% CI 1.22 to 6.98; p = 0.016); other non-robotically assisted UKA: zero to three months: HR 5.57 (95% CI 2.17 to 14.31; p < 0.001)). Conclusion. This study reports comparable short-term survivorship for the Mako robotically assisted UKA compared to the ZUK UKA and improved survivorship compared to all other non-robotic UKA. These results justify the continued use and investigation of this procedure. However, the higher rate of early revision for infection for robotically assisted UKA requires further investigation. Cite this article: Bone Joint J 2020;102-B(3):319–328


The Bone & Joint Journal
Vol. 106-B, Issue 1 | Pages 11 - 15
1 Jan 2024
Jain S Lamb JN Pandit H

Polished taper-slip (PTS) cemented stems have an excellent clinical track record and are the most common stem type used in primary total hip arthroplasty (THA) in the UK. Due to low rates of aseptic loosening, they have largely replaced more traditional composite beam (CB) cemented stems. However, there is now emerging evidence from multiple joint registries that PTS stems are associated with higher rates of postoperative periprosthetic femoral fracture (PFF) compared to their CB stem counterparts. The risk of both intraoperative and postoperative PFF remains greater with uncemented stems compared to either of these cemented stem subtypes. PFF continues to be a devastating complication following primary THA and is associated with high complication and mortality rates. Recent efforts have focused on identifying implant-related risk factors for PFF in order to guide preventative strategies, and therefore the purpose of this article is to present the current evidence on the effect of cemented femoral stem design on the risk of PFF.

Cite this article: Bone Joint J 2024;106-B(1):11–15.


Aims

The primary objective of this study was to compare the five-year tibial component migration and wear between highly crosslinked polyethylene (HXLPE) inserts and conventional polyethylene (PE) inserts of the uncemented Triathlon fixed insert cruciate-retaining total knee arthroplasty (TKA). Secondary objectives included clinical outcomes and patient-reported outcome measures (PROMs).

Methods

A double-blinded, randomized study was conducted including 96 TKAs. Tibial component migration and insert wear were measured with radiostereometric analysis (RSA) at three, six, 12, 24, and 60 months postoperatively. PROMS were collected preoperatively and at all follow-up timepoints.


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 130 - 136
1 Mar 2024
Morlock M Perka C Melsheimer O Kirschbaum SM

Aims

Despite higher rates of revision after total hip arthroplasty (THA) being reported for uncemented stems in patients aged > 75 years, they are frequently used in this age group. Increased mortality after cemented fixation is often used as a justification, but recent data do not confirm this association. The aim of this study was to investigate the influence of the design of the stem and the type of fixation on the rate of revision and immediate postoperative mortality, focusing on the age and sex of the patients.

Methods

A total of 333,144 patients with primary osteoarthritis (OA) of the hip who underwent elective THA between November 2012 and September 2022, using uncemented acetabular components without reconstruction shells, from the German arthroplasty registry were included in the study. The revision rates three years postoperatively for four types of stem (uncemented, uncemented with collar, uncemented short, and cemented) were compared within four age groups: < 60 years (Young), between 61 and 70 years (Mid-I), between 71 and 80 years (Mid-II), and aged > 80 years (Old). A noninferiority analysis was performed on the most frequently used designs of stem.


Aims

The aim of this study was to compare the migration of the femoral component, five years postoperatively, between patients with a highly cross-linked polyethylene (HXLPE) insert and those with a conventional polyethylene (PE) insert in an uncemented Triathlon fixed insert cruciate-retaining total knee arthroplasty (TKA). Secondary aims included clinical outcomes and patient-reported outcome measures (PROMs). We have previously reported the migration and outcome of the tibial components in these patients.

Methods

A double-blinded randomized controlled trial was conducted including 96 TKAs. The migration of the femoral component was measured with radiostereometry (RSA) at three and six months and one, two, and five years postoperatively. PROMs were collected preoperatively and at all periods of follow-up.


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 137 - 142
1 Mar 2024
van Veghel MHW van der Koelen RE Hannink G Schreurs BW Rijnen WHC

Aims

The aim of this study was to report the long-term follow-up of cemented short Exeter femoral components when used in primary total hip arthroplasty (THA).

Methods

We included all primary 394 THAs with a cemented short Exeter femoral component (≤ 125 mm) used in our tertiary referral centre between October 1993 and December 2021. A total of 83 patients (21%) were male. The median age of the patients at the time of surgery was 42 years (interquartile range (IQR) 30 to 55). The main indication for THA was a childhood hip disease (202; 51%). The median follow-up was 6.7 years (IQR 3.1 to 11.0). Kaplan-Meier survival analyses were performed to determine the rates of survival with femoral revision for any indication, for septic loosening, for fracture of the femoral component and for aseptic loosening as endpoints. The indications for revision were evaluated. Fractures of the femoral component were described in detail.


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1148 - 1155
1 Oct 2022
Watts AC Hamoodi Z McDaid C Hewitt C

Aims

Arthroplasties of the elbow, including total elbow arthroplasty, radial head arthroplasty, distal humeral hemiarthroplasty, and radiocapitellar arthroplasty, are rarely undertaken. This scoping review aims to outline the current research in this area to inform the development of future research.

Methods

A scoping review was undertaken adhering to the Joanna Briggs Institute guidelines using Medline, Embase, CENTRAL, and trial registries, limited to studies published between 1 January 1990 and 7 February 2021. Endnote software was used for screening and selection, and included randomized trials, non-randomized controlled trials, prospective and retrospective cohort studies, case-control studies, analytical cross-sectional studies, and case series of ten or more patients reporting the clinical outcomes of elbow arthroplasty. The results are presented as the number of types of studies, sample size, length of follow-up, clinical outcome domains and instruments used, sources of funding, and a narrative review.


The Bone & Joint Journal
Vol. 105-B, Issue 4 | Pages 422 - 430
15 Mar 2023
Riksaasen AS Kaur S Solberg TK Austevoll I Brox J Dolatowski FC Hellum C Kolstad F Lonne G Nygaard ØP Ingebrigtsen T

Aims

Repeated lumbar spine surgery has been associated with inferior clinical outcomes. This study aimed to examine and quantify the impact of this association in a national clinical register cohort.

Methods

This is a population-based study from the Norwegian Registry for Spine surgery (NORspine). We included 26,723 consecutive cases operated for lumbar spinal stenosis or lumbar disc herniation from January 2007 to December 2018. The primary outcome was the Oswestry Disability Index (ODI), presented as the proportions reaching a patient-acceptable symptom state (PASS; defined as an ODI raw score ≤ 22) and ODI raw and change scores at 12-month follow-up. Secondary outcomes were the Global Perceived Effect scale, the numerical rating scale for pain, the EuroQoL five-dimensions health questionnaire, occurrence of perioperative complications and wound infections, and working capability. Binary logistic regression analysis was conducted to examine how the number of previous operations influenced the odds of not reaching a PASS.


Bone & Joint Open
Vol. 4, Issue 2 | Pages 110 - 119
21 Feb 2023
Macken AA Prkić A van Oost I Spekenbrink-Spooren A The B Eygendaal D

Aims

The aim of this study is to report the implant survival and factors associated with revision of total elbow arthroplasty (TEA) using data from the Dutch national registry.

Methods

All TEAs recorded in the Dutch national registry between 2014 and 2020 were included. The Kaplan-Meier method was used for survival analysis, and a logistic regression model was used to assess the factors associated with revision.


Bone & Joint 360
Vol. 11, Issue 6 | Pages 49 - 50
1 Dec 2022
Evans JT Whitehouse MR


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 109 - 111
1 Feb 2023
Karjalainen T Buchbinder R

Tennis elbow (lateral epicondylitis or lateral elbow tendinopathy) is a self-limiting condition in most patients. Surgery is often offered to patients who fail to improve with conservative treatment. However, there is no evidence to support the superiority of surgery over continued nonoperative care or no treatment. New evidence also suggests that the prognosis of tennis elbow is not influenced by the duration of symptoms, and that there is a 50% probability of recovery every three to four months. This finding challenges the belief that failed nonoperative care is an indication for surgery. In this annotation, we discuss the clinical and research implications of the benign clinical course of tennis elbow.

Cite this article: Bone Joint J 2023;105-B(2):109–111.


Bone & Joint 360
Vol. 12, Issue 4 | Pages 44 - 46
1 Aug 2023
Burden EG Whitehouse MR Evans JT


Bone & Joint 360
Vol. 12, Issue 3 | Pages 16 - 18
1 Jun 2023

The June 2023 Knee Roundup360 looks at: Cementless total knee arthroplasty is associated with early aseptic loosening in a large national database; Is cementless total knee arthroplasty safe in females aged over 75 years?; Could novel radiological findings help identify aseptic tibial loosening?; The Attune cementless versus LCS arthroplasty at introduction; Return to work following total knee arthroplasty and unicompartmental knee arthroplasty; Complications and downsides of the robotic total knee arthroplasty; Mid-flexion instability in kinematic alignment better with posterior-stabilized and medial-stabilized implants?; Patellar resurfacing does not improve outcomes in modern knees.