Advertisement for orthosearch.org.uk
Results 1 - 20 of 30
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 914 - 919
1 Jul 2006
Grondal L Broström E Wretenberg P Stark A

In a prospective randomised study 31 patients were allocated to either arthrodesis or Mayo resection of the first metatarsophalangeal joint as part of a total reconstruction of the rheumatoid forefoot. Of these, 29 were re-examined after a mean of 72 months (57 to 80), the Foot Function Index was scored and any deformity measured. Load distribution was analysed using a Fscan mat in 14 cases, and time and distance were measured in 12 of these patients using a 3D Motion system. We found excellent patient satisfaction and a significant, lasting reduction of the Foot Function Index, with no statistically significant differences between the groups. There were no significant differences in recurrence of the deformity, the need for special shoes, gait velocity, step length, plantar moment, mean pressure or the position of the centre of force under the forefoot. The cadence was higher and the stance phase shorter in the fusion group. These results suggest that a Mayo resection may be an equally good option for managing the first metatarsophalangeal joint in reconstruction of the rheumatoid forefoot


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 1 | Pages 56 - 60
1 Jan 1996
Ishii T Miyagawa S Fukubayashi T Hayashi K

We investigated a new method of stress radiography of the subtalar joints using forced maximum dorsiflexion of the ankle in a supinated position. We measured transposition of the lateral process of the talus at the posterior subtalar joint in lateral views of normal amputated ankles, normal control subjects and patients with recurrent ankle sprains. The mean displacement in the control groups (n = 36) was 29.9%, significantly different from the 43.0% in patients with recurrent ankle sprains (n = 24). In the amputated specimens with intact ligaments movement was similar to that in normal subjects. Section of the calcaneofibular and the interosseous ligaments allowed much the same movement as in patients with recurrent ankle sprains. The new method is simple and useful for detecting subtalar instability


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 1 | Pages 99 - 101
1 Jan 1997
Finsen V Kasseth A

We studied perioperative pain and postoperative neurological changes after surgery for hallux valgus in 50 patients operated on under local ankle block. Patients were randomised to have the pneumatic tourniquet either at calf level or just above the ankle. The cuffs were inflated to 100 mmHg above systolic blood pressure. One patient was withdrawn from the study after randomisation. Areas of pain, paraesthesia and numbness were marked by patients on a diagram of the foot before operation and at six and ten weeks after operation. Both positions of the tourniquet gave an excellent bloodless field. The proximal tourniquet gave significantly greater discomfort (p < 0.01) during the operation, after 10, 20 and 30 minutes. Application of the cuff at the ankle gave no relative increase in areas of numbness and paraesthesia at six and ten weeks. An ankle tourniquet gives less discomfort with no increase in the incidence of nerve injury


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 7 | Pages 1016 - 1020
1 Sep 2004
Schneider W Aigner N Pinggera O Knahr K

The Chevron osteotomy was described in 1976. There have, however, been only short- to mid-term follow-up reviews, often with small numbers of patients. We looked at 112 feet (73 patients) with a minimum follow-up of ten years following Chevron osteotomy with a distal soft-tissue procedure. Clinical evaluation was calculated using the hallux score of the American Orthopedic Foot and Ankle Society (AOFAS). For 47 feet (30 patients), the results were compared with those from an interim follow-up of 5.6 years. The AOFAS-score improved from a pre-operative mean of 46.5 points to a mean of 88.8 points after a mean of 12.7 years. The first metatarsophalangeal (MTP) angle showed a mean pre-operative value of 27.6° and was improved to 14.0°. The first intermetatarsal (IM) angle improved from a pre-operative mean value of 13.8° to 8.7°. The mean pre-operative grade of sesamoid subluxation was 1.7 on a scale from 0 to 3 and improved to 1.2. Measured on a scale from 0 to 3, arthritis of the first MTP joint progressed from a mean of 0.8 to 1.7. Comparing the results in patients younger and older than 50 years, the Chevron osteotomy performed equally in both age groups. Analysing the subgroup of 47 feet with a post-operative follow-up of both 5.6 and 12.7 years, the AOFAS pain and the overall score showed a further improvement between both follow-up evaluations. The MTP angle, first IM angle and sesamoid position remained unchanged. The progression of arthritis of the first MTP joint between 5.6 and 12.7 years post-operatively was statistically significant. Only one patient required a revision procedure due to painful recurrence of the deformity. Excellent clinical results following Chevron osteotomy not only proved to be consistent, but showed further improvement over a longer follow-up period. The mean radiographic angles were constant without recurrence of the deformity. So far, the statistically significant progression of first MTP joint arthritis has not affected the clinical result, but this needs further observation


The Bone & Joint Journal
Vol. 96-B, Issue 10 | Pages 1349 - 1354
1 Oct 2014
Conway J Mansour J Kotze K Specht S Shabtai L

The treatment of infected nonunions is difficult. Antibiotic cement-coated (ACC) rods provide stability as well as delivering antibiotics. We conducted a review of 110 infected nonunions treated with ACC rods. Patients were divided into two groups: group A (67 patients) with an infected arthrodesis, and group B (43 patients) with an infected nonunion in a long bone. In group A, infected arthrodesis, the success rate after the first procedure was 38/67 (57%), 29/67 (43%) required further surgery for either control of infection or non-union. At last follow-up, five patients required amputation, representing a limb salvage rate of 62/67 (93%) overall. In all, 29/67 (43%) presented with a bone defect with a mean size of 6.78 cm (2 to 25). Of those with a bone defect, 13/29 (45%) required further surgery and had a mean size of defect of 7.2 cm (3.5 to 25). The cultures were negative in 17/67 (26%) and the most common organism cultured was methicillin-resistant staphylococcus aureus (MRSA) (23/67, (35%)). In group B, long bones nonunion, the success rate after the first procedure was 26/43 (60%), 17/43 (40%) required further surgery for either control of infection or nonunion. The limb salvage rate at last follow-up was 43/43 (100%). A total of 22/43 (51%) had bone defect with a mean size of 4.7 cm (1.5 to 11.5). Of those patients with a bone defect, 93% required further surgery with a mean size of defect of 5.4 cm (3 to 8.5). The cultures were negative in 10/43 (24%) and the most common organism cultured was MRSA, 15/43 (35%). ACC rods are an effective form of treatment for an infected nonunion, with an acceptable rate of complications.

Cite this article: Bone Joint J 2014; 96-B:1349–54


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1667 - 1672
1 Dec 2013
Oh C Apivatthakakul T Oh J Kim J Lee H Kyung H Baek S Jung G

Although gradual bone transport may permit the restoration of large-diameter bones, complications are common owing to the long duration of external fixation. In order to reduce such complications, a new technique of bone transport involving the use of an external fixator and a locking plate was devised for segmental tibial bone defects.

A total of ten patients (nine men, one woman) with a mean age at operation of 40.4 years (16 to 64) underwent distraction osteogenesis with a locking plate to treat previously infected post-traumatic segmental tibial defects. The locking plate was fixed percutaneously to bridge proximal and distal segments, and was followed by external fixation. After docking, percutaneous screws were fixed at the transported segment through plate holes. At the same time, bone grafting was performed at the docking site with the external fixator removed.

The mean defect size was 5.9 cm (3.8 to 9.3) and mean external fixation index was 13.4 days/cm (11.8 to 19.5). In all cases, primary union of the docking site and distraction callus was achieved, with an excellent bony result. There was no recurrence of deep infection or osteomyelitis, and with the exception of one patient with a pre-existing peroneal nerve injury, all achieved an excellent or good functional result.

With short external fixation times and low complication rates, bone transport with a locking plate could be recommended for patients with segmental tibial defects.

Cite this article: Bone Joint J 2013;95-B:1667–72.


Bone & Joint Research
Vol. 2, Issue 10 | Pages 227 - 232
1 Oct 2013
Kearney RS Parsons N Costa ML

Objectives

To conduct a pilot randomised controlled trial to evaluate the feasibility of conducting a larger trial to evaluate the difference in Victorian Institute of Sports Assessment-Achilles (VISA-A) scores at six months between patients with Achilles tendinopathy treated with a platelet-rich plasma (PRP) injection compared with an eccentric loading programme.

Methods

Two groups of patients with mid-substance Achilles tendinopathy were randomised to receive a PRP injection or an eccentric loading programme. A total of 20 patients were randomised, with a mean age of 49 years (35 to 66). All outcome measures were recorded at baseline, six weeks, three months and six months.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1241 - 1245
1 Sep 2012
Burghardt RD Paley D Specht SC Herzenberg JE

Internal lengthening devices in the femur lengthen along the anatomical axis, potentially creating lateral shift of the mechanical axis. We aimed to determine whether femoral lengthening along the anatomical axis has an inadvertent effect on lower limb alignment. Isolated femoral lengthening using the Intramedullary Skeletal Kinetic Distractor was performed in 27 femora in 24 patients (mean age 32 years (16 to 57)). Patients who underwent simultaneous realignment procedures or concurrent tibial lengthening, or who developed mal- or nonunion, were excluded. Pre-operative and six-month post-operative radiographs were used to measure lower limb alignment. The mean lengthening achieved was 4.4 cm (1.5 to 8.0). In 26 of 27 limbs, the mechanical axis shifted laterally by a mean of 1.0 mm/cm of lengthening (0 to 3.5). In one femur that was initially in varus, a 3 mm medial shift occurred during a lengthening of 2.2 cm.

In a normally aligned limb, intramedullary lengthening along the anatomical axis of the femur results in a lateral shift of the mechanical axis by approximately 1 mm for each 1 cm of lengthening.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 5 | Pages 660 - 662
1 May 2012
Aldridge SE Heilpern GNA Carmichael JR Sprowson AP Wood DG

Incomplete avulsion of the proximal hamstrings can be a severely debilitating injury that causes weakness, pain while sitting and inability to run. The results of the surgical treatment of 23 consecutive patients with such injuries at least two years after surgery are described. The surgery consisted of the repair of the hamstrings directly onto the ischial tuberosity. At review, using a visual analogue scale (VAS, 0 to 100), pain while sitting improved from a mean of 40 (0 to 100) to 64 (0 to 100) (p = 0.024), weakness from a mean of 39 (0 to 90) to 76 (7 to 100) (p = 0.0001) and the ability to run from a mean of 24 (0 to 88) to 64 (0 to 95) (p = 0.0001). According to a VAS, satisfaction was rated at a mean of 81 (0 to 100) and 20 patients (87%) would have the same procedure again. Hamstring strength measured pre- and post-operatively had improved significantly from a mean of 64% (0% to 95%) to 88% (50% to 114%) compared with the normal side.

Most of these patients with symptomatic incomplete hamstring avulsions unresponsive to conservative treatment had an improved outcome after surgical repair.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 75 - 79
1 Jan 2012
Herscovici, Jr D Scaduto JM

The use of autograft bone is the best option when undertaking a procedure that requires bone graft because it is osteogenic, osteoconductive and osseo-inductive. Pain, morbidity and complications associated with harvesting iliac or non-iliac sites occur in between 6% and 30% of cases. An alternative source of graft with possibly a lower morbidity is the intramedullary canal. In this study, 28 patients undergoing 30 arthrodesis procedures on the hindfoot had a mean of 48 cm3 (43 to 50) of bone harvested locally from the hindfoot or the tibial shaft by antegrade or retrograde reaming. No patient sustained a fracture of the calcaneum, talus or tibia. There was no morbidity except for one complication when the reamer breached the medial tibial cortex. This healed uneventfully.

This method of using the reamer–irrigator–aspirator system is an extension of the standard technique of intramedullary reaming of the lower limb: it produces good-quality bone graft with viable growth factors consistent with that of the iliac crest, and donor site morbidity is low. This is an efficient method of obtaining autologous bone for use in arthrodesis of the ankle or hindfoot.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 7 | Pages 928 - 931
1 Jul 2011
Waton A Kakwani R Cooke NJ Litchfield D Kok D Middleton H Irwin L

The purpose of this study was to investigate the effects of right leg restriction at the knee, ankle or both, on a driver’s braking times. Previous studies have not investigated the effects of knee restriction on braking performance. A total of 23 healthy drivers performed a series of emergency braking tests in a driving simulator in either an above-knee plaster cast, a below-knee cast, or in a knee brace with an increasing range of restriction. The study showed that total braking reaction time was significantly longer when wearing an above-knee plaster cast, a below-knee plaster cast or a knee brace fixed at 0°, compared with braking normally (p < 0.001). Increases in the time taken to move the foot from the accelerator to the brake accounted for some of the increase in the total braking reaction time. Unexpectedly, thinking time also increased with the level of restriction (p < 0.001). The increase in braking time with an above-knee plaster cast in this study would increase the stopping distance at 30 miles per hour by almost 3 m.

These results suggest that all patients wearing any lower-limb plaster cast or knee brace are significantly impaired in their ability to perform an emergency stop. We suggest changes to the legislation to prevent patients from driving with lower-limb plaster casts or knee braces.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1234 - 1240
1 Sep 2012
Willcox NMJ Clarke JV Smith BRK Deakin AH Deep K

We compared lower limb coronal alignment measurements obtained pre- and post-operatively with long-leg radiographs and computer navigation in patients undergoing primary total knee replacement (TKR). A series of 185 patients had their pre- and post-implant radiological and computer-navigation system measurements of coronal alignment compared using the Bland-Altman method. The study included 81 men and 104 women with a mean age of 68.5 years (32 to 87) and a mean body mass index of 31.7 kg/m2 (19 to 49). Pre-implant Bland–Altman limits of agreement were -9.4° to 8.6° with a repeatability coefficient of 9.0°. The Bland–Altman plot showed a tendency for the radiological measurement to indicate a higher level of pre-operative deformity than the corresponding navigation measurement. Post-implant limits of agreement were -5.0° to 5.4° with a repeatability coefficient of 5.2°. The tendency for valgus knees to have greater deformity on the radiograph was still seen, but was weaker for varus knees.

The alignment seen or measured intra-operatively during TKR is not necessarily the same as the deformity seen on a standing long-leg radiograph either pre- or post-operatively. Further investigation into the effect of weight-bearing and surgical exposure of the joint on the mechanical femorotibial angle is required to enable the most appropriate intra-operative alignment to be selected.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 782 - 787
1 Jun 2011
Sun X Easwar TR Manesh S Ryu J Song S Kim S Song H

We compared the complications and outcome of tibial lengthening using the Ilizarov method with and without the use of a supplementary intramedullary nail. In a retrospective case-matched series assembled from 176 patients with tibial lengthening, we matched 52 patients (26 pairs, group A with nail and group B without) according to the following criteria in order of importance: 1) difference in amount of lengthening (± 2 cm); 2) percentage difference in lengthening (± 5%); 3) difference in patient’s age (± seven years); 4) aetiology of the shortening, and 5) level of difficulty in obtaining the correction. The outcome was evaluated using the external fixator index, the healing index and an outcome score according to the criteria of Paley. It was found that some complications were specific to group A or B respectively, but others were common to both groups.

The outcome was generally better in lengthenings with a nail, although there was a higher incidence of rectifiable equinus deformity in these patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 788 - 792
1 Jun 2011
Schiedel FM Pip S Wacker S Pöpping J Tretow H Leidinger B Rödl R

We report the results of intramedullary leg lengthening conducted between 2002 and 2009 using the Intramedullary Skeletal Kinetic Distractor in 69 unilateral lengthenings involving 58 femora and 11 tibiae. We identified difficulties that occurred during the treatment and assessed whether they were specifically due to the implant or independent of it. Paley’s classification for evaluating problems, obstacles and complications with external fixators was adopted, and implant-specific difficulties were continuously noted. There were seven failures requiring premature removal of the device, in four due to nail breakage and three for other reasons, and five unsuccessful outcomes after completion of the lengthening. In all, 116 difficulties were noted in 45 patients, with only 24 having problem-free courses. In addition to the difficulties arising from the use of external fixators, there were almost the same number again of implant-specific difficulties.

Nevertheless, successful femoral lengthening was achieved in 52 of the 58 patients (90%). However, successful tibial lengthening was only achieved in five of 11 patients (45%).


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 639 - 643
1 May 2011
Burghardt RD Herzenberg JE Specht SC Paley D

Between October 2001 and September 2009 we lengthened 242 lower-limb segments in 180 patients using the Intramedullary Skeletal Kinetic Distractor (ISKD). Mechanical failure was defined either as breakage of the ISKD or failure of the internal mechanism to activate. Retrieved nails which failed mechanically were examined by the manufacturer for defects. In all, 15 ISKDs in 12 patients (13 limbs) failed mechanically representing an overall failure rate of 6.2%, with fracture of the device occurring in ten of the 15 failures. Two nails in one patient failed to lengthen and had to be replaced. The manufacturer detected an error in the assembly of the nail, which prompted a wide recall. One nail jammed after being forcefully inserted, and two nails failed to lengthen fully. Lengthening was achieved in all 12 patients, although three required a second operation to exchange a defective nail for a new, functioning device.

The ISKD is a complex mechanical device which lengthens by the oscillation of two telescopic sections connected by a threaded rod. The junction between these sections is surrounded by a keyring collar. This keyring collar is the weakest part of the device.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 3 | Pages 323 - 326
1 Mar 2007
Citak M Kendoff D Kfuri M Pearle A Krettek C Hüfner T

The aim of this pilot study was to evaluate the accuracy of two different methods of navigated retrograde drilling of talar lesions. Artificial osteochondral talar lesions were created in 14 cadaver lower limbs. Two methods of navigated drilling were evaluated by one examiner. Navigated Iso-C3D was used in seven cadavers and 2D fluoroscopy-based navigation in the remaining seven. Of 14 talar lesions, 12 were successfully targeted by navigated drilling. In both cases of inaccurate targeting the 2D fluoroscopy-based navigation was used, missing lesions by 3 mm and 5 mm, respectively. The mean radiation time was increased using Iso-C3D navigation (23 s; 22 to 24) compared with 2D fluoroscopy-based navigation (14 s, 11 to 17).


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 1 | Pages 52 - 56
1 Jan 2011
Kocaoglu M Bilen FE Sen C Eralp L Balci HI

We present the results of the surgical correction of lower-limb deformities caused by metabolic bone disease. Our series consisted of 17 patients with a diagnosis of hypophosphataemic rickets and two with renal osteodystrophy; their mean age was 25.6 years (14 to 57). In all, 43 lower-limb segments (27 femora and 16 tibiae) were osteotomised and the deformity corrected using a monolateral external fixator. The segment was then stabilised with locked intramedullary nailing. In addition, six femora in three patients were subsequently lengthened by distraction osteogenesis. The mean follow-up was 60 months (18 to 120). The frontal alignment parameters (the mechanical axis deviation, the lateral distal femoral angle and the medial proximal tibial angle) and the sagittal alignment parameters (the posterior distal femoral angle and the posterior proximal tibial angle) improved post-operatively. The external fixator was removed either at the end of surgery or at the end of the lengthening period, allowing for early mobilisation and weight-bearing. We encountered five problems and four obstacles in the programme of treatment.

The use of intramedullary nails prevented recurrence of deformity and refracture.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 343 - 347
1 Mar 2005
Winson IG Robinson DE Allen PE

We reviewed 116 patients who underwent 118 arthroscopic ankle arthrodeses. The mean age at operation was 57 years, 2 months (20 to 86 years). The indication for operation was post-traumatic osteoarthritis in 67, primary osteoarthritis in 36, inflammatory arthropathy in 13 and avascular necrosis in two. The mean follow-up was 65 months (18 to 144). Nine patients (10 ankles) died before final review and three were lost to follow-up, leaving 104 patients (105 ankles) who were assessed by a standard telephone interview. The pre-operative talocrural deformity was between 22° valgus and 28° varus, 94 cases were within 10° varus/valgus. The mean time to union was 12 weeks (6 to 20). Nonunion occurred in nine cases (7.6%). Other complications included 22 cases requiring removal of a screw for prominence, three superficial infections, two deep vein thromboses/pulmonary emboli, one revision of fixation, one stress fracture and one deep infection. Six patients had a subtalar fusion at a mean of 48 months after ankle fusion. There were 48 patients with excellent, 35 with good, 10 with fair and 11 with poor clinical results.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 69 - 77
1 Jan 2006
Costa ML MacMillan K Halliday D Chester R Shepstone L Robinson AHN Donell ST

We performed two independent, randomised, controlled trials in order to assess the potential benefits of immediate weight-bearing mobilisation after rupture of the tendo Achillis. The first trial, on operatively-treated patients showed an improved functional outcome for patients mobilised fully weight-bearing after surgical repair. Two cases of re-rupture in the treatment group suggested that careful patient selection is required as patients need to follow a structured rehabilitation regimen. The second trial, on conservatively-treated patients, provided no evidence of a functional benefit from immediate weight-bearing mobilisation. However, the practical advantages of immediate weight-bearing did not predispose the patients to a higher complication rate. In particular, there was no evidence of tendon lengthening or a higher re-rupture rate. We would advocate immediate weight-bearing mobilisation for the rehabilitation of all patients with rupture of the tendo Achillis.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 5 | Pages 614 - 619
1 May 2006
Scranton PE Frey CC Feder KS

The treatment of osteochondral lesions of the talus has evolved with the development of improved imaging and arthroscopic techniques. However, the outcome of treatment for large cystic type-V lesions is poor, using conventional grafting, debridement or microfracture techniques.

This retrospective study examined the outcomes of 50 patients with a cystic talar defect who were treated with arthroscopically harvested, cored osteochondral graft taken from the ipsilateral knee.

Of the 50 patients, 45 (90%) had a mean good to excellent score of 80.3 (52 to 90) in the Karlsson-Peterson Ankle Score, at a mean follow-up of 36 months (24 to 83). A malleolar osteotomy for exposure was needed in 26 patients and there were no malleolar mal- or nonunions. One patient had symptoms at the donor site three months after surgery; these resolved after arthroscopic release of scar tissue.

This technique is demanding with or without a malleolar osteotomy, but if properly performed has a high likelihood of success.