Advertisement for orthosearch.org.uk
Results 1 - 20 of 95
Results per page:
The Bone & Joint Journal
Vol. 100-B, Issue 2 | Pages 233 - 241
1 Feb 2018
Ohmori T Kitamura T Nishida T Matsumoto T Tokioka T

Aim. There is not adequate evidence to establish whether external fixation (EF) of pelvic fractures leads to a reduced mortality. We used the Japan Trauma Data Bank database to identify isolated unstable pelvic ring fractures to exclude the possibility of blood loss from other injuries, and analyzed the effectiveness of EF on mortality in this group of patients. Patients and Methods. This was a registry-based comparison of 1163 patients who had been treated for an isolated unstable pelvic ring fracture with (386 patients) or without (777 patients) EF. An isolated pelvic ring fracture was defined by an Abbreviated Injury Score (AIS) for other injuries of < 3. An unstable pelvic ring fracture was defined as having an AIS ≥ 4. The primary outcome of this study was mortality. A subgroup analysis was carried out for patients who required blood transfusion within 24 hours of arrival in the Emergency Department and those who had massive blood loss (AIS code: 852610.5). Propensity-score matching was used to identify a cohort like the EF and non-EF groups. Results. With the use of propensity-score matching using the completed data, 346 patients were matched. When the propensity-score matching was adjusted, EF was associated with a significantly lower risk of death (p = 0.047). In the subgroup analysis of patients who needed blood transfusion within 24 hours and those who had massive blood loss, EF was associated with a significantly lower risk of death in patients who needed blood transfusion within 24 hours (p = 0.014) and in those with massive blood loss (p = 0.016). Conclusion. The use of EF to treat unstable pelvic ring fractures was associated with a significantly lower risk of death, especially in patients with severe fractures. Cite this article: Bone Joint J 2018;100-B:233–41


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 10 | Pages 1344 - 1346
1 Oct 2007
Lakshmanan P Sharma A Lyons K Peehal JP

We have evaluated retrospectively the relationship of bony injuries seen on 106 consecutive MR scans in elderly patients of a mean age of 81.4 years (67 to 101) who were unable to bear weight after a low-energy injury. There were no visible fractures on plain radiographs of the hip but eight patients (7.5%) had fractures of the pubic ramus. In 43 patients (40.5%) MRI revealed a fracture of the femoral neck and in 26 (24.5%) there was a fracture of a pubic ramus. In 17 patients (16%) MRI showed an occult sacral fracture and all of these had a fracture of the pubic ramus. No patient with a fracture of the femoral neck had an associated fracture of the pelvic ring or vice versa. Occult fracture of the hip and of the pelvic ring appear to be mutually exclusive and if an acute fracture of the pubic ramus is diagnosed radiologically further investigations are not needed to rule out an occult fracture of the hip


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 9 | Pages 1201 - 1207
1 Sep 2009
Lefaivre KA Starr AJ Barker BP Overturf S Reinert CM

We describe our early operative experience with a new pelvic reduction frame and the standard of reduction of fractures of the pelvic ring which we achieved in the first 35 consecutive patients, with 34 acute fractures and one nonunion. The pre-operative and immediate post-operative radiographs were measured, using two methods, to find the maximum radiological displacement of the fracture and the quality of the reduction according to the criteria of Tornetta and Matta. There were 19 vertical shear fractures and 16 compression injuries. The mean age of the patients was 33.5 years (10 to 59) and mean delay to surgery was 4.6 days (0 to 16) in the 34 acute injuries. The mean operative time in isolated procedures was 103.4 minutes (. sd. 6.5). All but one patient had iliosacral screws implanted, 18 had screws in the anterior column, six had plates at the symphysis pubis and 12 had anterior external fixators. The mean maximum horizontal or vertical displacement was improved from 30.8 mm (. sd. 2.7) to a mean of 7.1 mm (. sd. 0.7). The reduction was assessed as excellent in ten patients, good in 18, and fair in the remainder. There was no significant influence on the quality of the reduction caused by obesity (p = 0.34), the type of fracture (p = 0.41) or delay to surgery (p = 0.83). The frame was shown to be effective, allowing the surgeon to obtain a satisfactory reduction and fixation of acute displaced disruptions of the pelvic ring


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 4 | Pages 549 - 555
1 Apr 2012
Lefaivre KA Slobogean GP Valeriote J O’Brien PJ Macadam SA

We performed a systematic review of the literature to evaluate the use and interpretation of generic and disease-specific functional outcome instruments in the reporting of outcome after the surgical treatment of disruptions of the pelvic ring. A total of 28 papers met our inclusion criteria, with eight reporting only generic outcome instruments, 13 reporting only pelvis-specific outcome instruments, and six reporting both. The Short-Form 36 (SF-36) was by far the most commonly used generic outcome instrument, used in 12 papers, with widely variable reporting of scores. The pelvis-specific outcome instruments were used in 19 studies; the Majeed score in ten, Iowa pelvic score in six, Hannover pelvic score in two and the Orlando pelvic score in one. Four sets of authors, all testing construct validity based on correlation with the SF-36, performed psychometric testing of three pelvis-specific instruments (Majeed, IPS and Orlando scores). No testing of responsiveness, content validity, criterion validity, internal consistency or reproducibility was performed. The existing literature in this area is inadequate to inform surgeons or patients in a meaningful way about the functional outcomes of these fractures after fixation


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 6 | Pages 955 - 962
1 Nov 1999
Lindahl J Hirvensalo E Böstman O Santavirta S

We reviewed 110 patients with an unstable fracture of the pelvic ring who had been treated with a trapezoidal external fixator after a mean follow-up of 4.1 years. There were eight open-book (type B1, B3-1) injuries, 62 lateral compression (type B2, B3-2) and 40 rotationally and vertically unstable (type C1-C3) injuries. The rate of complications was high with loss of reduction in 57%, malunion in 58%, nonunion in 5%, infection at the pin site in 24%, loosening of the pins in 2%, injury to the lateral femoral cutaneous nerve in 2%, and pressure sores in 3%. The external fixator failed to give and maintain a proper reduction in six of the eight open-book injuries, in 20 of the 62 lateral compression injuries, and in 38 of the 40 type-C injuries. Poor functional results were usually associated with failure of reduction and an unsatisfactory radiological appearance. In type-C injuries more than 10 mm of residual vertical displacement of the injury to the posterior pelvic ring was significantly related to poor outcome. In 14 patients in this unsatisfactory group poor functional results were also affected by associated nerve injuries. In lateral compression injuries the degree of displacement of fractures of the pubic rami caused by internal rotation of the hemipelvis was an important prognostic factor. External fixation may be useful in the acute phase of resuscitation but it is of limited value in the definitive treatment of an unstable type-C injury and in type-B open-book injuries. It is usually unnecessary in minimally displaced lateral compression injuries


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 880 - 888
1 Jul 2019
Wei R Guo W Yang R Tang X Yang Y Ji T Liang H

Aims. The aim of this study was to describe the use of 3D-printed sacral endoprostheses to reconstruct the pelvic ring and re-establish spinopelvic stability after total en bloc sacrectomy (TES) and to review its outcome. Patients and Methods. We retrospectively reviewed 32 patients who underwent TES in our hospital between January 2015 and December 2017. We divided the patients into three groups on the basis of the method of reconstruction: an endoprosthesis group (n = 10); a combined reconstruction group (n = 14), who underwent non-endoprosthetic combined reconstruction, including anterior spinal column fixation; and a spinopelvic fixation (SPF) group (n = 8), who underwent only SPF. Spinopelvic stability, implant survival (IS), intraoperative haemorrhage rate, and perioperative complication rate in the endoprosthesis group were documented and compared with those of other two groups. Results. The mean overall follow-up was 22.1 months (9 to 44). In the endoprosthesis group, the mean intraoperative hemorrhage was 3530 ml (1600 to 8100). Perioperative complications occurred in two patients; both had problems with wound healing. After a mean follow-up of 17.7 months (12 to 38), 9/10 patients could walk without aids and 8/10 patients were not using analgesics. Imaging evidence of implant failure was found in three patients, all of whom had breakage of screws and/or rods. Only one of these, who had a local recurrence, underwent re-operation, at which solid bone-endoprosthetic osseointegration was found. The mean IS using re-operation as the endpoint was 32.5 months (95% confidence interval 23.2 to 41.8). Compared with the other two groups, the endoprosthesis group had significantly better spinopelvic stability and IS with no greater intraoperative haemorrhage or perioperative complications. Conclusion. The use of 3D-printed endoprostheses for reconstruction after TES provides reliable spinopelvic stability and IS by facilitating osseointegration at the bone-implant interfaces, with acceptable levels of haemorrhage and complications. Cite this article: Bone Joint J 2019;101-B:880–888


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 3 | Pages 438 - 440
1 May 1997
Pennig D Gladbach B Majchrowski W

A young woman sustained disruption of the anterior pelvic ring with bony avulsion of the symphysis pubis during a spontaneous delivery. Anterior external fixation allowed a full functional recovery


Bone & Joint Research
Vol. 6, Issue 1 | Pages 8 - 13
1 Jan 2017
Acklin YP Zderic I Grechenig S Richards RG Schmitz P Gueorguiev B

Objectives. Osteosynthesis of anterior pubic ramus fractures using one large-diameter screw can be challenging in terms of both surgical procedure and fixation stability. Small-fragment screws have the advantage of following the pelvic cortex and being more flexible. The aim of the present study was to biomechanically compare retrograde intramedullary fixation of the superior pubic ramus using either one large- or two small-diameter screws. Materials and Methods. A total of 12 human cadaveric hemipelvises were analysed in a matched pair study design. Bone mineral density of the specimens was 68 mgHA/cm. 3. (standard deviation (. sd). 52). The anterior pelvic ring fracture was fixed with either one 7.3 mm cannulated screw (Group 1) or two 3.5 mm pelvic cortex screws (Group 2). Progressively increasing cyclic axial loading was applied through the acetabulum. Relative movements in terms of interfragmentary displacement and gap angle at the fracture site were evaluated by means of optical movement tracking. The Wilcoxon signed-rank test was applied to identify significant differences between the groups. Results. Initial axial construct stiffness was not significantly different between the groups (p = 0.463). Interfragmentary displacement and gap angle at the fracture site were also not statistically significantly different between the groups throughout the evaluated cycles (p ⩾ 0.249). Similarly, cycles to failure were not statistically different between Group 1 (8438, . sd. 6968) and Group 2 (10 213, . sd. 10 334), p = 0.379. Failure mode in both groups was characterised by screw cutting through the cancellous bone. Conclusion. From a biomechanical point of view, pubic ramus stabilisation with either one large or two small fragment screw osteosynthesis is comparable in osteoporotic bone. However, the two-screw fixation technique is less demanding as the smaller screws deflect at the cortical margins. Cite this article: Y. P. Acklin, I. Zderic, S. Grechenig, R. G. Richards, P. Schmitz, B. Gueorguiev. Are two retrograde 3.5 mm screws superior to one 7.3 mm screw for anterior pelvic ring fixation in bones with low bone mineral density? Bone Joint Res 2017;6:8–13. DOI: 10.1302/2046-3758.61.BJR-2016-0261


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 3 | Pages 411 - 418
1 Apr 2003
Ziran BH Smith WR Towers J Morgan SJ

Various techniques have been used for the fixation of the posterior pelvis, each with disadvantages specific to the technique. In this study, a new protocol involving the placement of posterior pelvic screws in the CT suite is described and evaluated. A total of 66 patients with unstable pelvic ring injuries was stabilised under local anaesthesia with sedation. The mean length of time for the procedure was 26 minutes per screw. There were no technical difficulties or misplaced screws and no cases of infection or nonunion. All patients stated that they would choose to have the CT scan procedure again rather than a procedure requiring general anaesthesia. The charges for the procedure were approximately £1840 ($2800) per operation. CT-guided placement of iliosacral screws is a safe, feasible, and cost-effective alternative to radiologically-guided placement in the operating theatre in selected patients


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 548 - 553
1 Apr 2013
Dienstknecht T Pfeifer R Horst K Sellei RM Berner A Zelle BA Probst C Pape H

We report the functional and socioeconomic long-term outcome of patients with pelvic ring injuries. We identified 109 patients treated at a Level I trauma centre between 1973 and 1990 with multiple blunt orthopaedic injuries including an injury to the pelvic ring, with an Injury Severity Score (ISS) of ≥ 16. These patients were invited for clinical review at a minimum of ten years after the initial injury, at which point functional results, general health scores and socioeconomic factors were assessed. In all 33 isolated anterior (group A), 33 isolated posterior (group P) and 43 combined anterior/posterior pelvic ring injuries (group A/P) were included. The mean age of the patients at injury was 28.8 years (5 to 55) and the mean ISS was 22.7 (16 to 44). At review the mean Short-Form 12 physical component score for the A/P group was 38.71 (22.12 to 56.56) and the mean Hannover Score for Polytrauma Outcome subjective score was 67.27 (12.48 to 147.42), being significantly worse compared with the other two groups (p = 0.004 and p = 0.024, respectively). A total of 42 patients (39%) had a limp and 12 (11%) required crutches. Car or public transport usage was restricted in 16 patients (15%). Overall patients in groups P and A/P had a worse outcome. The long-term outcome of patients with posterior or combined anterior/posterior pelvic ring injuries is poorer than of those with an isolated anterior injury. Cite this article: Bone Joint J 2013;95-B:548–53


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 4 | Pages 427 - 433
1 Apr 2006
van Vugt AB van Kampen A


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 145 - 154
1 Feb 2007
Giannoudis PV Tzioupis CC Pape H Roberts CS

With the development of systems of trauma care the management of pelvic disruption has evolved and has become increasingly refined. The goal is to achieve an anatomical reduction and stable fixation of the fracture. This requires adequate visualisation for reduction of the fracture and the placement of fixation. Despite the advances in surgical approach and technique, the functional outcomes do not always produce the desired result. New methods of percutaneous treatment in conjunction with innovative computer-based imaging have evolved in an attempt to overcome the existing difficulties. This paper presents an overview of the technical aspects of percutaneous surgery of the pelvis and acetabulum.


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1232 - 1236
1 Sep 2017
Dahill M McArthur J Roberts GL Acharya MR Ward AJ Chesser TJS

Aims

The anterior pelvic internal fixator is increasingly used for the treatment of unstable, or displaced, injuries of the anterior pelvic ring. The evidence for its use, however, is limited. The aim of this paper is to describe the indications for its use, how it is applied and its complications.

Patients and Methods

We reviewed the case notes and radiographs of 50 patients treated with an anterior pelvic internal fixator between April 2010 and December 2015 at a major trauma centre in the United Kingdom. The median follow-up time was 38 months (interquartile range 24 to 51).


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 11 | Pages 1524 - 1528
1 Nov 2011
Bonner TJ Eardley WGP Newell N Masouros S Matthews JJ Gibb I Clasper JC

The aim of this study was to assess the accuracy of placement of pelvic binders and to determine whether circumferential compression at the level of the greater trochanters is the best method of reducing a symphyseal diastasis.

Patients were identified by a retrospective review of all pelvic radiographs performed at a military hospital over a period of 30 months. We analysed any pelvic radiograph on which the buckle of the pelvic binder was clearly visible. The patients were divided into groups according to the position of the buckle in relation to the greater trochanters: high, trochanteric or low. Reduction of the symphyseal diastasis was measured in a subgroup of patients with an open-book fracture, which consisted of an injury to the symphysis and disruption of the posterior pelvic arch (AO/OTA 61-B/C).

We identified 172 radiographs with a visible pelvic binder. Five cases were excluded due to inadequate radiographs. In 83 (50%) the binder was positioned at the level of the greater trochanters. A high position was the most common site of inaccurate placement, occurring in 65 (39%). Seventeen patients were identified as a subgroup to assess the effect of the position of the binder on reduction of the diastasis. The mean gap was 2.8 times greater (mean difference 22 mm) in the high group compared with the trochanteric group (p < 0.01).

Application of a pelvic binder above the level of the greater trochanters is common and is an inadequate method of reducing pelvic fractures and is likely to delay cardiovascular recovery in these seriously injured patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 6 | Pages 941 - 943
1 Nov 1999
Tile M


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 1 | Pages 1 - 12
1 Jan 1988
Tile M


The Bone & Joint Journal
Vol. 100-B, Issue 9 | Pages 1214 - 1219
1 Sep 2018
Winkelmann M Lopez Izquierdo M Clausen J Liodakis E Mommsen P Blossey R Krettek C Zeckey C

Aims. This study aimed to analyze the correlation between transverse process (TP) fractures of the fourth (L4) and fifth (L5) lumbar vertebrae and biomechanical and haemodynamic stability in patients with a pelvic ring injury, since previous data are inconsistent. Patients and Methods. The study is a retrospective matched-pair analysis of patients with a pelvic fracture according to the modified Tile AO Müller and the Young and Burgess classification who presented to a level 1 trauma centre between January 2005 and December 2014. Results. A total of 728 patients with pelvic ring injuries were included, of whom 183 (25.1%) had a biomechanically unstable pelvic fracture. Of these patients, 84 (45.9%) had a fracture of a TP of L4 and/or L5. A total of 73 patients (13.4%) with a stable pelvic ring injury (p < 0.001) had a fracture of a TP. Patients with a fracture of a TP of L4 and/or L5 had a 5.5-fold risk (odds ratio (OR)) of having a biomechanically unstable pelvic injury. TP fractures (OR 1.6, p = 0.2) could not be confirmed as an independent predictor of haemodynamic instability. Conclusion. This is the first study that has demonstrated a positive correlation between a TP fracture of L4 and/or L5 and a biomechanically unstable pelvic ring injury. The presence of transverse process fractures of L4 and/or L5 indicates increased severity of pelvic injury and therefore can help in the planning of emergency treatment. Cite this article: Bone Joint J 2018;100-B:1214–19


Bone & Joint 360
Vol. 12, Issue 1 | Pages 36 - 39
1 Feb 2023

The February 2023 Trauma Roundup. 360. looks at: Masquelet versus bone transport in infected nonunion of tibia; Hyperbaric Oxygen for Lower Limb Trauma (HOLLT): an international multicentre randomized clinical trial; Is the T-shaped acetabular fracture really a “T”?; What causes cut-out of proximal femur nail anti-rotation device in intertrochanteric fractures?; Is the common femoral artery at risk with percutaneous fragility pelvis fixation?; Anterior pelvic ring pattern predicts displacement in lateral compression fractures; Differences in age-related characteristics among elderly patients with hip fractures


Bone & Joint Open
Vol. 5, Issue 5 | Pages 385 - 393
13 May 2024
Jamshidi K Toloue Ghamari B Ammar W Mirzaei A

Aims. Ilium is the most common site of pelvic Ewing’s sarcoma (ES). Resection of the ilium and iliosacral joint causes pelvic disruption. However, the outcomes of resection and reconstruction are not well described. In this study, we report patients’ outcomes after resection of the ilium and iliosacral ES and reconstruction with a tibial strut allograft. Methods. Medical files of 43 patients with ilium and iliosacral ES who underwent surgical resection and reconstruction with a tibial strut allograft between January 2010 and October 2021 were reviewed. The lesions were classified into four resection zones: I. 1. , I. 2. , I. 3. , and I. 4. , based on the extent of resection. Functional outcomes, oncological outcomes, and surgical complications for each resection zone were of interest. Functional outcomes were assessed using a Musculoskeletal Tumor Society (MSTS) score and Toronto Extremity Salvage Score (TESS). Results. The mean age of the patients was 17 years (SD 9.1). At a mean follow-up of 70.8 months (SD 50), the mean functional outcomes were 24.2 points (SD 6.3) for MSTS and 81 points (SD 11) for TESS. The mean MSTS and TESS scores were associated with the iliac resection zone (< 0.001). Nine patients (20.9%) had local recurrence. The recurrence was not associated with the zone of iliac resection (p = 0.324). The two-year disease-free survival of the patients was 69.4%. The mean time to graft union was longer in patients with the I. 4. resection zone (p < 0.001). The complication rate was 34.9%, and nerve palsy (11.6%) was the most common. The rate of surgical complications was not associated with the resection zone. Conclusion. Reconstruction using tibial strut allograft is an efficient procedure after the resection of the ilium and iliosacral ES. Functional outcomes and complications of iliac ES depend on the resection zone, and inferior outcomes could be generally expected when more segments of the pelvic ring are resected, even if it is reconstructed. Cite this article: Bone Jt Open 2024;5(5):385–393


Aims. For rare cases when a tumour infiltrates into the hip joint, extra-articular resection is required to obtain a safe margin. Endoprosthetic reconstruction following tumour resection can effectively ensure local control and improve postoperative function. However, maximizing bone preservation without compromising surgical margin remains a challenge for surgeons due to the complexity of the procedure. The purpose of the current study was to report clinical outcomes of patients who underwent extra-articular resection of the hip joint using a custom-made osteotomy guide and 3D-printed endoprosthesis. Methods. We reviewed 15 patients over a five-year period (January 2017 to December 2022) who had undergone extra-articular resection of the hip joint due to malignant tumour using a custom-made osteotomy guide and 3D-printed endoprosthesis. Each of the 15 patients had a single lesion, with six originating from the acetabulum side and nine from the proximal femur. All patients had their posterior column preserved according to the surgical plan. Results. Postoperative pathological assessment revealed a negative surgical margin was achieved in all patients. At final follow-up, 13.3% (2/15) died and no recurrence occurred. The overall survival was 81.7% at five years. None of the patients showed any signs of aseptic loosening, and no wound healing issues were observed. In total, 20% (3/15) developed complications, with two cases of early hip dislocation and one case of deep infection. The cumulative incidence of mechanical and non-mechanical failure in this series was 13.7% and 9.3%, respectively, at five years. In this cohort, the mean time to full weightbearing was 5.89 (SD 0.92) weeks and the mean Musculoskeletal Tumor Society score was 24.1 (SD 4.4). Conclusion. For patients with a hip joint tumour who met the inclusion criteria and were deemed suitable for posterior column preservation, a custom-made osteotomy guide combined with 3D-printed endoprosthesis is worth performing when treating patients who require extra-articular resection of the hip joint, as it can achieve adequate margin for local control, maximize bone preservation to maintain pelvic ring integrity, reduce the risk of complications by simplifying the surgical procedure, and allow for more precise reconstruction for better function. Cite this article: Bone Jt Open 2024;5(11):1027–1036