Advertisement for orthosearch.org.uk
Results 1 - 20 of 81
Results per page:
Bone & Joint Research
Vol. 12, Issue 2 | Pages 103 - 112
1 Feb 2023
Walter N Szymski D Kurtz SM Lowenberg DW Alt V Lau E Rupp M

Aims

The optimal choice of management for proximal humerus fractures (PHFs) has been increasingly discussed in the literature, and this work aimed to answer the following questions: 1) what are the incidence rates of PHF in the geriatric population in the USA; 2) what is the mortality rate after PHF in the elderly population, specifically for distinct treatment procedures; and 3) what factors influence the mortality rate?

Methods

PHFs occurring between 1 January 2009 and 31 December 2019 were identified from the Medicare physician service records. Incidence rates were determined, mortality rates were calculated, and semiparametric Cox regression was applied, incorporating 23 demographic, clinical, and socioeconomic covariates, to compare the mortality risk between treatments.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 230 - 234
1 Feb 2010
Anderson GA Thomas BP Pallapati SCR

Inability to actively supinate the forearm makes common activities of daily living and certain vocational activities awkward or impossible to perform. A total of 11 patients with deficient supination of the arm underwent transfer of the tendon of flexor carpi ulnaris to the split tendon of brachioradialis with its bony insertion into the radial styloid left intact. Active supination beyond neutral rotation was a mean of 37.2° (25° to 49.5°) at a minimum follow-up of three years, representing a significant improvement (95% confidence interval 25 to 50, p < 0.001). Functional evaluation of the hand after this transfer showed excellent and good results in ten patients and fair in one. The split tendon of brachioradialis as an insertion for transfer of the flexor carpi ulnaris appears to provide adequate supination of the forearm without altering the available pronation and avoids the domination of wrist extension sometimes associated with transfers of the flexor carpi ulnaris to the radial extensors of the wrist


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 3 | Pages 406 - 413
1 May 1999
McMahon PJ Dettling J Sandusky MD Tibone JE Lee TQ

Surgical treatment for traumatic, anterior glenohumeral instability requires repair of the anterior band of the inferior glenohumeral ligament, usually at the site of glenoid insertion, often combined with capsuloligamentous plication. In this study, we determined the mechanical properties of this ligament and the precise anatomy of its insertion into the glenoid in fresh-frozen glenohumeral joints of cadavers. Strength was measured by tensile testing of the glenoid-soft-tissue-humerus (G-ST-H) complex. Two other specimens of the complex were frozen in the position of apprehension, serially sectioned perpendicular to the plane containing the anterior and posterior rims of the glenoid, and stained with Toluidine Blue. On tensile testing, eight G-ST-H complexes failed at the site of the glenoid insertion, representing a Bankart lesion, two at the insertion into the humerus, and two at the midsubstance. For those which failed at the glenoid attachment the mean yield load was 491.0 N and the mean ultimate load, 585.0 N. At the glenoid region, stress at yield was 7.8 ± 1.3 MPa and stress at failure, 9.2 ± 1.5 MPa. The permanent deformation, defined as the difference between yield and ultimate deformation, was only 2.3 ± 0.8 mm. The strain at yield was 13.0 ± 0.7% and at failure, 15.4 ± 1.2%; therefore permanent strain was only 2.4 ± 1.1%. Histological examination showed that there were two attachments of the anterior band of the inferior glenohumeral ligament at the site of the glenoid insertion. In one, poorly organised collagen fibres inserted into the labrum. In the other, dense collagen fibres were attached to the front of the neck of the glenoid


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 5 | Pages 668 - 670
1 May 2012
Gu YP Zhu SM

We describe a new surgical technique for the treatment of lacerations of the extensor tendon in zone I, which involves a tenodesis using a length of palmaris longus tendon one-quarter of its width. After exposing the dorsal aspect of the distal interphalangeal joint and harvesting the tendon, a 1.5 mm drill bit is passed through the insertion of the extensor tendon into the distal phalanx where it penetrates through the skin of the pulp of the digit. The palmaris longus tendon is threaded through the drill hole from dorsal to ventral and the ventral end is tied in a simple knot and trimmed. The palmaris longus tendon is then sutured to the extensor tendon close to its insertion, and also at the middle of the middle phalanx. The operation was undertaken on 67 patients: 27 with an acute injury and 40 patients with a chronic mallet deformity. One finger (or the thumb) was involved in each patient. At a mean follow-up of 12 months (6 to 18), 66 patients (98.5%) received excellent or good results according to both the American Society for Surgery of the Hand (ASSH) classification and Miller’s classification. Tenodesis using palmaris longus tendon after complete division of an extensor tendon in zone 1 is a reliable form of treatment for isolated acute or chronic ruptures


Bone & Joint Research
Vol. 10, Issue 5 | Pages 298 - 306
1 May 2021
Dolkart O Kazum E Rosenthal Y Sher O Morag G Yakobson E Chechik O Maman E

Aims

Rotator cuff (RC) tears are common musculoskeletal injuries which often require surgical intervention. Noninvasive pulsed electromagnetic field (PEMF) devices have been approved for treatment of long-bone fracture nonunions and as an adjunct to lumbar and cervical spine fusion surgery. This study aimed to assess the effect of continuous PEMF on postoperative RC healing in a rat RC repair model.

Methods

A total of 30 Wistar rats underwent acute bilateral supraspinatus tear and repair. A miniaturized electromagnetic device (MED) was implanted at the right shoulder and generated focused PEMF therapy. The animals’ left shoulders served as controls. Biomechanical, histological, and bone properties were assessed at three and six weeks.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 1 | Pages 82 - 87
1 Jan 2009
Charalambous CP Stanley JK Siddique I Aster A Gagey O

The lateral ligament complex is the primary constraint to posterolateral rotatory laxity of the elbow, and if it is disrupted during surgery, posterolateral instability may ensue. The Wrightington approach to the head of the radius involves osteotomising the ulnar insertion of this ligament, rather than incising through it as in the classic posterolateral (Kocher) approach. In this biomechanical study of 17 human cadaver elbows, we demonstrate that the surgical approach to the head can influence posterolateral laxity, with the Wrightington approach producing less posterolateral rotatory laxity than the posterolateral approach


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1397 - 1402
1 Oct 2010
Nada AN Debnath UK Robinson DA Jordan C

We describe the clinical outcome of a technique of surgical augmentation of chronic massive tears of the rotator cuff using a polyester ligament (Dacron) in 21 symptomatic patients (14 men, seven women) with a mean age of 66.5 years (55.0 to 85.0). All patients had MRI and arthroscopic evidence of chronic massive tears. The clinical outcome was assessed using the Constant and Murley and patient satisfaction scores at a mean follow-up of 36 months (30 to 46). The polyester ligament (500 mm × 10 mm) was passed into the joint via the portal of Neviaser, medial to the tear through healthy cuff. The two ends of the ligament holding the cuff were passed through tunnels made in the proximal humerus at the footprint of the insertion of the cuff. The ligament was tied with a triple knot over the humeral cortex. All the patients remained free from pain (p < 0.001) with improvement in function (p < 0.001) and range of movement (p < 0.001). The mean pre-operative and post-operative Constant scores were 46.7 (39.0 to 61.0) and 85.4 (52.0 to 96.0), respectively (p < 0.001). The mean patient satisfaction score was 90%. There were two failures, one due to a ruptured ligament after one year and the other due to deep-seated infection. The MR scan at the final follow-up confirmed intact and thickened bands in 15 of 17 patients. This technique of augmentation gives consistent relief from pain with improved shoulder movement in patients with symptomatic massive tears of the rotator cuff


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 5 | Pages 620 - 626
1 May 2007
Nath RK Paizi M

Residual muscle weakness in obstetric brachial plexus palsy results in soft-tissue contractures which limit the functional range of movement and lead to progressive glenoid dysplasia and joint instability. We describe the results of surgical treatment in 98 patients (mean age 2.5 years, 0.5 to 9.0) for the correction of active abduction of the shoulder. The patients underwent transfer of the latissimus dorsi and teres major muscles, release of contractures of subscapularis pectoralis major and minor, and axillary nerve decompression and neurolysis (the modified Quad procedure). The transferred muscles were sutured to the teres minor muscle, not to a point of bony insertion. The mean pre-operative active abduction was 45° (20° to 90°). At a mean follow-up of 4.8 years (2.0 to 8.7), the mean active abduction was 162° (100° to 180°) while 77 (78.6%) of the patients had active abduction of 160° or more. No decline in abduction was noted among the 29 patients (29.6%) followed up for six years or more. This procedure involving release of the contracted internal rotators of the shoulder combined with decompression and neurolysis of the axillary nerve greatly improves active abduction in young patients with muscle imbalance secondary to obstetric brachial plexus palsy


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 5 | Pages 623 - 628
1 May 2006
Gong HS Chung MS Lee YH Lee S Lee JO Baek GH

We have performed a form of lunate replacement arthroplasty, which included excision of the lunate and insertion of a vascularised radial bone flap wrapped in pronator quadratus, for stage IIIB or stage IV Kienböck’s disease, in 41 patients who have been followed up for more than three years. All patients reported an improvement in their symptoms, and 20 of the 41 became free of pain after the operation. Extension and flexion of the wrist were increased by a mean of 9° and 6°, respectively (p < 0.05). The radioscaphoid angle and the carpal height ratio were not significantly changed and only minimal deterioration was observed due to degenerative change. The size, density or location of the inserted bone did not change with time. A vascularised radial bone flap wrapped in pronator quadratus can be a reliable treatment option for advanced Kienböck’s disease, when the pedicled bone and muscle envelope acts as a stable spacer for the excised lunate


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 9 | Pages 1173 - 1177
1 Sep 2006
Kean J Wigderowitz CA Coventry DM

We performed a double-blind, randomised controlled trial to assess the effectiveness of a continuous-infusion brachial plexus block with levobupivacaine compared with that of a standard single injection for the management of post-operative pain after surgery on the shoulder. Eight patients were randomised to receive a pre-operative brachial plexus block using 30 ml of levobupivacaine 0.5% with adrenaline 1:200 000 followed by insertion of a 20-gauge polyamide catheter. This was connected to a disposable elastometric pump, set immediately after surgery to administer a continuous flow of levobupivacaine 0.25% at a rate of 5 ml per hour. The other eight patients were randomised to receive only the initial injection of 30 ml. The study was double-blinded with the aid of sham catheters and clamped pumps. All patients were given regular paracetamol and were prescribed morphine through a patient-controlled analgesia pump. Motor and sensory block assessments, visual analogue scale pain scores and consumption of morphine were recorded after the operation and then at 6, 12 and 24 hours after administration of the block. Satisfactory motor and sensory block was achieved in all patients. The mean visual analogue scale pain score at 12 hours and consumption of morphine at 24 hours after injection were significantly lower (p < 0.05) in the continuous-infusion group. This group also took longer to request their first additional analgesia and reported a significantly higher overall level of satisfaction. Our study has shown that continuous interscalene infusion of levobupivacaine is an effective method of post-operative analgesia after major surgery of the shoulder


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 3 | Pages 388 - 395
1 Apr 2004
Sirveaux F Favard L Oudet D Huquet D Walch G Mole D

We reviewed 80 shoulders (77 patients) at a mean follow-up of 44 months after insertion of a Grammont inverted shoulder prosthesis. Three implants had failed and had been revised. The mean Constant score had increased from 22.6 points pre-operatively to 65.6 points at review. In 96% of these shoulders there was no or only minimal pain. The mean active forward elevation increased from 73° to 138°. The integrity of teres minor is essential for the recovery of external rotation and significantly influenced the Constant score. Five cases of aseptic loosening of the glenoid and seven of dissociation of the glenoid component were noted. This study confirms the promising early results obtained with the inverted prosthesis in the treatment of a cuff-tear arthropathy. It should be considered in the treatment of osteoarthritis with a massive tear of the cuff but should be reserved for elderly patients


Bone & Joint Research
Vol. 8, Issue 3 | Pages 118 - 125
1 Mar 2019
Doi N Izaki T Miyake S Shibata T Ishimatsu T Shibata Y Yamamoto T

Objectives

Indocyanine green (ICG) fluorescence angiography is an emerging technique that can provide detailed anatomical information during surgery. The purpose of this study is to determine whether ICG fluorescence angiography can be used to evaluate the blood flow of the rotator cuff tendon in the clinical setting.

Methods

Twenty-six patients were evaluated from October 2016 to December 2017. The participants were categorized into three groups based on their diagnoses: the rotator cuff tear group; normal rotator cuff group; and adhesive capsulitis group. After establishing a posterior standard viewing portal, intravenous administration of ICG at 0.2 mg/kg body weight was performed, and fluorescence images were recorded. The time from injection of the drug to the beginning of enhancement of the observed area was measured. The hypovascular area in the rotator cuff was evaluated, and the ratio of the hypovascular area to the anterolateral area of the rotator cuff tendon was calculated (hypovascular area ratio).


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 1 | Pages 109 - 113
1 Jan 1998
Rühmann O Wirth CJ Gossé F Schmolke S

Most brachial plexus palsies are due to trauma, often resulting from motorcycle accidents. When nerve repair and physiotherapy are unsuccessful, muscle transfer may be considered. Paralysis of the deltoid and supraspinatus muscles can be addressed by transfer of the trapezius. Between March 1994 and June 1997 we treated 38 patients with brachial plexus palsy by trapezius transfer and reviewed 31 of these (7 women, 24 men) after a mean follow-up of 23.8 months (12 to 39), reporting the clinical and radiological results and subjective assessment. The mean age of the patients was 29 years (18 to 46). The operations had been performed according to the method of Saha described in 1967, involving transfer of the acromion with the insertion of the trapezius to the proximal humerus, and immobilisation in an abduction support for six weeks. Rehabilitation started on the first postoperative day with active exercises for the elbow, hand and fingers, and electrical stimulation of the transferred trapezius. All 31 patients had improved function with a decrease in multidirectional instability of the shoulder. The average increase in active abduction was from 7.3° (0 to 45) to 39° (25 to 80) at the latest review. The mean forward flexion increased from 20° (0 to 85) to 44° (20 to 90). Twenty-nine of the 31 were satisfied with the improvement in stability and function. Trapezius transfer for brachial plexus palsy involving the shoulder improves function and stability with clear subjective benefits


Bone & Joint Research
Vol. 7, Issue 6 | Pages 422 - 429
1 Jun 2018
Acklin YP Zderic I Inzana JA Grechenig S Schwyn R Richards RG Gueorguiev B

Aims

Plating displaced proximal humeral fractures is associated with a high rate of screw perforation. Dynamization of the proximal screws might prevent these complications. The aim of this study was to develop and evaluate a new gliding screw concept for plating proximal humeral fractures biomechanically.

Methods

Eight pairs of three-part humeral fractures were randomly assigned for pairwise instrumentation using either a prototype gliding plate or a standard PHILOS plate, and four pairs were fixed using the gliding plate with bone cement augmentation of its proximal screws. The specimens were cyclically tested under progressively increasing loading until perforation of a screw. Telescoping of a screw, varus tilting and screw migration were recorded using optical motion tracking.


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 517 - 522
1 Apr 2013
Henry PDG Dwyer T McKee MD Schemitsch EH

Latissimus dorsi tendon transfer (LDTT) is technically challenging. In order to clarify the local structural anatomy, we undertook a morphometric study using six complete cadavers (12 shoulders). Measurements were made from the tendon to the nearby neurovascular structures with the arm in two positions: flexed and internally rotated, and adducted in neutral rotation. The tendon was then transferred and measurements were taken from the edge of the tendon to a reference point on the humeral head in order to assess the effect of a novel two-stage release on the excursion of the tendon.

With the shoulder flexed and internally rotated, the mean distances between the superior tendon edge and the radial nerve, brachial artery, axillary nerve and posterior circumflex artery were 30 mm (26 to 34), 28 mm (17 to 39), 21 mm (12 to 28) and 15 mm (10 to 21), respectively. The mean distance between the inferior tendon edge and the radial nerve, brachial artery and profunda brachii artery was 18 mm (8 to 27), 22 mm (15 to 32) and 14 mm (7 to 21), respectively. Moving the arm to a neutral position reduced these distances. A mean of 15 mm (8 to 21) was gained from a standard soft-tissue release, and 32 mm (20 to 45) from an extensile release.

These figures help to define further the structural anatomy of this region and the potential for transfer of the latissimus dorsi tendon.

Cite this article: Bone Joint J 2013;95-B:517–22.


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 660 - 663
1 May 2013
Ghosh S Singh VK Jeyaseelan L Sinisi M Fox M

In adults with brachial plexus injuries, lack of active external rotation at the shoulder is one of the most common residual deficits, significantly compromising upper limb function. There is a paucity of evidence to address this complex issue. We present our experience of isolated latissimus dorsi (LD) muscle transfer to achieve active external rotation. This is a retrospective review of 24 adult post-traumatic plexopathy patients who underwent isolated latissimus dorsi muscle transfer to restore external rotation of the shoulder between 1997 and 2010. All patients were male with a mean age of 34 years (21 to 57). All the patients underwent isolated LD muscle transfer using a standard technique to correct external rotational deficit. Outcome was assessed for improvement in active external rotation, arc of movement, muscle strength and return to work. The mean improvement in active external rotation from neutral was 24° (10° to 50°). The mean increase in arc of rotation was 52° (38° to 55°). Mean power of the external rotators was 3.5 Medical Research Council (MRC) grades (2 to 5).

A total of 21 patients (88%) were back in work by the time of last follow up. Of these, 13 had returned to their pre-injury occupation. Isolated latissimus dorsi muscle transfer provides a simple and reliable method of restoring useful active external rotation in adults with brachial plexus injuries with internal rotational deformity.

Cite this article: Bone Joint J 2013;95-B:660–3.


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 721 - 731
1 Jun 2013
Sewell MD Al-Hadithy N Le Leu A Lambert SM

The sternoclavicular joint (SCJ) is a pivotal articulation in the linked system of the upper limb girdle, providing load-bearing in compression while resisting displacement in tension or distraction at the manubrium sterni. The SCJ and acromioclavicular joint (ACJ) both have a small surface area of contact protected by an intra-articular fibrocartilaginous disc and are supported by strong extrinsic and intrinsic capsular ligaments. The function of load-sharing in the upper limb by bulky periscapular and thoracobrachial muscles is extremely important to the longevity of both joints. Ligamentous and capsular laxity changes with age, exposing both joints to greater strain, which may explain the rising incidence of arthritis in both with age. The incidence of arthritis in the SCJ is less than that in the ACJ, suggesting that the extrinsic ligaments of the SCJ provide greater stability than the coracoclavicular ligaments of the ACJ.

Instability of the SCJ is rare and can be difficult to distinguish from medial clavicular physeal or metaphyseal fracture-separation: cross-sectional imaging is often required. The distinction is important because the treatment options and outcomes of treatment are dissimilar, whereas the treatment and outcomes of ACJ separation and fracture of the lateral clavicle can be similar. Proper recognition and treatment of traumatic instability is vital as these injuries may be life-threatening. Instability of the SCJ does not always require surgical intervention. An accurate diagnosis is required before surgery can be considered, and we recommend the use of the Stanmore instability triangle. Most poor outcomes result from a failure to recognise the underlying pathology.

There is a natural reluctance for orthopaedic surgeons to operate in this area owing to unfamiliarity with, and the close proximity of, the related vascular structures, but the interposed sternohyoid and sternothyroid muscles are rarely injured and provide a clear boundary to the medial retroclavicular space, as well as an anatomical barrier to unsafe intervention.

This review presents current concepts of instability of the SCJ, describes the relevant surgical anatomy, provides a framework for diagnosis and management, including physiotherapy, and discusses the technical challenges of operative intervention.

Cite this article: Bone Joint J 2013;95-B:721–31.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 12 | Pages 1666 - 1669
1 Dec 2012
Gulotta LV Choi D Marinello P Wright T Cordasco FA Craig EV Warren RF

Reverse total shoulder replacement (RTSR) depends on adequate deltoid function for a successful outcome. However, the anterior deltoid and/or axillary nerve may be damaged due to prior procedures or injury. The purpose of this study was to determine the compensatory muscle forces required for scapular plane elevation following RTSR when the anterior deltoid is deficient. The soft tissues were removed from six cadaver shoulders, except for tendon attachments. After implantation of the RTSR, the shoulders were mounted on a custom-made shoulder simulator to determine the mean force in each muscle required to achieve 30° and 60° of scapular plane elevation. Two conditions were tested: 1) Control with an absent supraspinatus and infraspinatus; and 2) Control with anterior deltoid deficiency. Anterior deltoid deficiency resulted in a mean increase of 195% in subscapularis force at 30° when compared with the control (p = 0.02). At 60°, the subscapularis force increased a mean of 82% (p < 0.001) and the middle deltoid force increased a mean of 26% (p = 0.04).

Scapular plane elevation may still be possible following an RTSR in the setting of anterior deltoid deficiency. When the anterior deltoid is deficient, there is a compensatory increase in the force required by the subscapularis and middle deltoid. Attempts to preserve the subscapularis, if present, might maximise post-operative function.


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 523 - 529
1 Apr 2013
Henseler JF Nagels J van der Zwaal P Nelissen RGHH

Surgical repair of posterosuperior rotator cuff tears has a poorer outcome and a higher rate of failure compared with repairs of supraspinatus tears. In this prospective cohort study 28 consecutive patients with an irreparable posterosuperior rotator cuff tear after failed conservative or surgical treatment underwent teres major tendon transfer. Their mean age was 60 years (48 to 71) and the mean follow-up was 25 months (12 to 80). The mean active abduction improved from 79° (0° to 150°) pre-operatively to 105° (20° to 180°) post-operatively (p = 0.011). The mean active external rotation in 90° abduction improved from 25° (0° to 70°) pre-operatively to 55° (0° to 90°) post-operatively (p < 0.001). The mean Constant score improved from 43 (18 to 78) pre-operatively to 65 (30 to 86) post-operatively (p < 0.001). The median post-operative VAS (0 to 100) for pain decreased from 63 (0 to 96) pre-operatively to 5 (0 to 56) post-operatively (p < 0.001).

In conclusion, teres major transfer effectively restores function and relieves pain in patients with irreparable posterosuperior rotator cuff tears and leads to an overall clinical improvement in a relatively young and active patient group with limited treatment options.

Cite this article: Bone Joint J 2013;95-B:523–9.


Bone & Joint Research
Vol. 1, Issue 7 | Pages 158 - 166
1 Jul 2012
Dean BJF Franklin SL Carr AJ

Introduction

The pathogenesis of rotator cuff disease (RCD) is complex and not fully understood. This systematic review set out to summarise the histological and molecular changes that occur throughout the spectrum of RCD.

Methods

We conducted a systematic review of the scientific literature with specific inclusion and exclusion criteria.