Advertisement for orthosearch.org.uk
Results 1 - 16 of 16
Results per page:
The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 696 - 702
1 May 2016
Theologis AA Burch S Pekmezci M

Aims. We compared the accuracy, operating time and radiation exposure of the introduction of iliosacral screws using O-arm/Stealth Navigation and standard fluoroscopy. Materials and Methods. Iliosacral screws were introduced percutaneously into the first sacral body (S1) of ten human cadavers, four men and six women. The mean age was 77 years (58 to 85). Screws were introduced using a standard technique into the left side of S1 using C-Arm fluoroscopy and then into the right side using O-Arm/Stealth Navigation. The radiation was measured on the surgeon by dosimeters placed under a lead thyroid shield and apron, on a finger, a hat and on the cadavers. Results. There were no neuroforaminal breaches in either group. The set-up time for the O-Arm was significantly longer than for the C-Arm, while total time for placement of the screws was significantly shorter for the O-Arm than for the C-Arm (p = 0.001). The mean absorbed radiation dose during fluoroscopy was 1063 mRad (432.5 mRad to 4150 mRad). No radiation was detected on the surgeon during fluoroscopy, or when he left the room during the use of the O-Arm. The mean radiation detected on the cadavers was significantly higher in the O-Arm group (2710 mRem standard deviation (. sd. ) 1922) than during fluoroscopy (11.9 mRem . sd 14.8). (p < 0.01). Conclusion. O-Arm/Stealth Navigation allows for faster percutaneous placement of iliosacral screws in a radiation-free environment for surgeons, albeit with the same accuracy and significantly more radiation exposure to cadavers, when compared with standard fluoroscopy. Take home message: Placement of iliosacral screws with O-Arm/Stealth Navigation can be performed safely and effectively. Cite this article: Bone Joint J 2016;98-B:696–702


The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 705 - 710
1 May 2015
Ozmeric A Yucens M Gultaç E Açar HI Aydogan NH Gül D Alemdaroglu KB

We hypothesised that the anterior and posterior walls of the body of the first sacral vertebra could be visualised with two different angles of inlet view, owing to the conical shape of the sacrum. Six dry male cadavers with complete pelvic rings and eight dry sacrums with K-wires were used to study the effect of canting (angling the C-arm) the fluoroscope towards the head in 5° increments from 10° to 55°. Fluoroscopic images were taken in each position. Anterior and posterior angles of inclination were measured between the upper sacrum and the vertical line on the lateral view. Three authors separately selected the clearest image for overlapping anterior cortices and the upper sacral canal in the cadaveric models. The dry bone and K-wire models were scored by the authors, being sure to check whether the K-wire was in or out. In the dry bone models the mean score of the relevant inlet position of the anterior or posterior inclination was 8.875 (standard deviation (. sd. ) 0.35), compared with the inlet position of the opposite inclination of –5.75 (. sd. 4.59). We found that two different inlet views should be used separately to evaluate the borders of the body of the sacrum using anterior and posterior inclination angles of the sacrum, during placement of iliosacral screws. Cite this article: Bone Joint J 2015;97-B:705–10


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 3 | Pages 411 - 418
1 Apr 2003
Ziran BH Smith WR Towers J Morgan SJ

Various techniques have been used for the fixation of the posterior pelvis, each with disadvantages specific to the technique. In this study, a new protocol involving the placement of posterior pelvic screws in the CT suite is described and evaluated. A total of 66 patients with unstable pelvic ring injuries was stabilised under local anaesthesia with sedation. The mean length of time for the procedure was 26 minutes per screw. There were no technical difficulties or misplaced screws and no cases of infection or nonunion. All patients stated that they would choose to have the CT scan procedure again rather than a procedure requiring general anaesthesia. The charges for the procedure were approximately £1840 ($2800) per operation. CT-guided placement of iliosacral screws is a safe, feasible, and cost-effective alternative to radiologically-guided placement in the operating theatre in selected patients


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 237 - 244
1 Feb 2011
Berber O Amis AA Day AC

The purpose of this study was to assess the stability of a developmental pelvic reconstruction system which extends the concept of triangular osteosynthesis with fixation anterior to the lumbosacral pivot point. An unstable Tile type-C fracture, associated with a sacral transforaminal fracture, was created in synthetic pelves. The new concept was compared with three other constructs, including bilateral iliosacral screws, a tension band plate and a combined plate with screws. The pubic symphysis was plated in all cases. The pelvic ring was loaded to simulate single-stance posture in a cyclical manner until failure, defined as a displacement of 2 mm or 2°. The screws were the weakest construct, failing with a load of 50 N after 400 cycles, with maximal translation in the craniocaudal axis of 12 mm. A tension band plate resisted greater load but failure occurred at 100 N, with maximal rotational displacement around the mediolateral axis of 2.3°. The combination of a plate and screws led to an improvement in stability at the 100 N load level, but rotational failure still occurred around the mediolateral axis. The pelvic reconstruction system was the most stable construct, with a maximal displacement of 2.1° of rotation around the mediolateral axis at a load of 500 N


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 9 | Pages 1201 - 1207
1 Sep 2009
Lefaivre KA Starr AJ Barker BP Overturf S Reinert CM

We describe our early operative experience with a new pelvic reduction frame and the standard of reduction of fractures of the pelvic ring which we achieved in the first 35 consecutive patients, with 34 acute fractures and one nonunion. The pre-operative and immediate post-operative radiographs were measured, using two methods, to find the maximum radiological displacement of the fracture and the quality of the reduction according to the criteria of Tornetta and Matta. There were 19 vertical shear fractures and 16 compression injuries. The mean age of the patients was 33.5 years (10 to 59) and mean delay to surgery was 4.6 days (0 to 16) in the 34 acute injuries. The mean operative time in isolated procedures was 103.4 minutes (. sd. 6.5). All but one patient had iliosacral screws implanted, 18 had screws in the anterior column, six had plates at the symphysis pubis and 12 had anterior external fixators. The mean maximum horizontal or vertical displacement was improved from 30.8 mm (. sd. 2.7) to a mean of 7.1 mm (. sd. 0.7). The reduction was assessed as excellent in ten patients, good in 18, and fair in the remainder. There was no significant influence on the quality of the reduction caused by obesity (p = 0.34), the type of fracture (p = 0.41) or delay to surgery (p = 0.83). The frame was shown to be effective, allowing the surgeon to obtain a satisfactory reduction and fixation of acute displaced disruptions of the pelvic ring


Bone & Joint 360
Vol. 11, Issue 5 | Pages 34 - 36
1 Oct 2022


Bone & Joint 360
Vol. 12, Issue 3 | Pages 30 - 32
1 Jun 2023

The June 2023 Spine Roundup360 looks at: Characteristics and comparative study of thoracolumbar spine injury and dislocation fracture due to tertiary trauma; Sublingual sufentanil for postoperative pain management after lumbar spinal fusion surgery; Minimally invasive bipolar technique for adult neuromuscular scoliosis; Predictive factors for degenerative lumbar spinal stenosis; Lumbosacral transitional vertebrae and lumbar fusion surgery at level L4/5; Does recall of preoperative scores contaminate trial outcomes? A randomized controlled trial; Vancomycin in fibrin glue for prevention of SSI; Perioperative nutritional supplementation decreases wound healing complications following elective lumbar spine surgery: a randomized controlled trial.


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 261 - 267
1 Feb 2020
Tøndevold N Lastikka M Andersen T Gehrchen M Helenius I

Aims

It is uncertain whether instrumented spinal fixation in nonambulatory children with neuromuscular scoliosis should finish at L5 or be extended to the pelvis. Pelvic fixation has been shown to be associated with up to 30% complication rates, but is regarded by some as the standard for correction of deformity in these conditions. The incidence of failure when comparing the most caudal level of instrumentation, either L5 or the pelvis, using all-pedicle screw instrumentation has not previously been reported. In this retrospective study, we compared nonambulatory patients undergoing surgery at two centres: one that routinely instrumented to L5 and the other to the pelvis.

Methods

In all, 91 nonambulatory patients with neuromuscular scoliosis were included. All underwent surgery using bilateral, segmental, pedicle screw instrumentation. A total of 40 patients underwent fusion to L5 and 51 had their fixation extended to the pelvis. The two groups were assessed for differences in terms of clinical and radiological findings, as well as complications.


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1232 - 1236
1 Sep 2017
Dahill M McArthur J Roberts GL Acharya MR Ward AJ Chesser TJS

Aims

The anterior pelvic internal fixator is increasingly used for the treatment of unstable, or displaced, injuries of the anterior pelvic ring. The evidence for its use, however, is limited. The aim of this paper is to describe the indications for its use, how it is applied and its complications.

Patients and Methods

We reviewed the case notes and radiographs of 50 patients treated with an anterior pelvic internal fixator between April 2010 and December 2015 at a major trauma centre in the United Kingdom. The median follow-up time was 38 months (interquartile range 24 to 51).


Bone & Joint 360
Vol. 4, Issue 6 | Pages 21 - 23
1 Dec 2015

The December 2015 Trauma Roundup360 looks at: Delay to surgery in hip fracture; Hexapod fixators in the management of hypertrophic tibial nonunions; Thromboembolism after nailing pathological fractures; Tibial plateau fracture patterns under the spotlight; The health economic effects of long bone nonunion; Adverse outcomes in trauma; The sacral screw in children; Treating the contralateral SUFE


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 145 - 154
1 Feb 2007
Giannoudis PV Tzioupis CC Pape H Roberts CS

With the development of systems of trauma care the management of pelvic disruption has evolved and has become increasingly refined. The goal is to achieve an anatomical reduction and stable fixation of the fracture. This requires adequate visualisation for reduction of the fracture and the placement of fixation. Despite the advances in surgical approach and technique, the functional outcomes do not always produce the desired result. New methods of percutaneous treatment in conjunction with innovative computer-based imaging have evolved in an attempt to overcome the existing difficulties. This paper presents an overview of the technical aspects of percutaneous surgery of the pelvis and acetabulum.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 5 | Pages 651 - 658
1 May 2007
Day AC Kinmont C Bircher MD Kumar S

Crescent fracture dislocations are a well-recognised subset of pelvic ring injuries which result from a lateral compression force. They are characterised by disruption of the sacroiliac joint and extend proximally as a fracture of the posterior iliac wing. We describe a classification with three distinct types. Type I is characterised by a large crescent fragment and the dislocation comprises no more than one-third of the sacroiliac joint, which is typically inferior. Type II fractures are associated with an intermediate-size crescent fragment and the dislocation comprises between one- and two-thirds of the joint. Type III fractures are associated with a small crescent fragment where the dislocation comprises most, but not all of the joint. The principal goals of surgical intervention are the accurate and stable reduction of the sacroiliac joint. This classification proves useful in the selection of both the surgical approach and the reduction technique. A total of 16 patients were managed according to this classification and achieved good functional results approximately two years from the time of the index injury. Confounding factors compromise the summary short-form-36 and musculoskeletal functional assessment instrument scores, which is a well-recognised phenomenon when reporting the outcome of high-energy trauma.


The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 696 - 704
1 May 2015
Kenawey M Krettek C Addosooki A Salama W Liodakis E

Unstable pelvic injuries in young children with an immature pelvis have different modes of failure from those in adolescents and adults. We describe the pathoanatomy of unstable pelvic injuries in these children, and the incidence of associated avulsion of the iliac apophysis and fracture of the ipsilateral fifth lumbar transverse process (L5-TP). We retrospectively reviewed the medical records of 33 children with Tile types B and C pelvic injuries admitted between 2007 and 2014; their mean age was 12.6 years (2 to 18) and 12 had an immature pelvis. Those with an immature pelvis commonly sustained symphyseal injuries anteriorly with diastasis, rather than the fractures of the pubic rami seen in adolescents. Posteriorly, transsacral fractures were more commonly encountered in mature children, whereas sacroiliac dislocations and fracture-dislocations were seen in both age groups. Avulsion of the iliac apophysis was identified in eight children, all of whom had an immature pelvis with an intact ipsilateral L5-TP. Young children with an immature pelvis are more susceptible to pubic symphysis and sacroiliac diastasis, whereas bony failures are more common in adolescents. Unstable pelvic injuries in young children are commonly associated with avulsion of the iliac apophysis, particularly with displaced SI joint dislocation and an intact ipsilateral L5-TP.

Cite this article: Bone Joint J 2015; 97-B:696–704.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 11 | Pages 1524 - 1528
1 Nov 2011
Bonner TJ Eardley WGP Newell N Masouros S Matthews JJ Gibb I Clasper JC

The aim of this study was to assess the accuracy of placement of pelvic binders and to determine whether circumferential compression at the level of the greater trochanters is the best method of reducing a symphyseal diastasis.

Patients were identified by a retrospective review of all pelvic radiographs performed at a military hospital over a period of 30 months. We analysed any pelvic radiograph on which the buckle of the pelvic binder was clearly visible. The patients were divided into groups according to the position of the buckle in relation to the greater trochanters: high, trochanteric or low. Reduction of the symphyseal diastasis was measured in a subgroup of patients with an open-book fracture, which consisted of an injury to the symphysis and disruption of the posterior pelvic arch (AO/OTA 61-B/C).

We identified 172 radiographs with a visible pelvic binder. Five cases were excluded due to inadequate radiographs. In 83 (50%) the binder was positioned at the level of the greater trochanters. A high position was the most common site of inaccurate placement, occurring in 65 (39%). Seventeen patients were identified as a subgroup to assess the effect of the position of the binder on reduction of the diastasis. The mean gap was 2.8 times greater (mean difference 22 mm) in the high group compared with the trochanteric group (p < 0.01).

Application of a pelvic binder above the level of the greater trochanters is common and is an inadequate method of reducing pelvic fractures and is likely to delay cardiovascular recovery in these seriously injured patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 4 | Pages 549 - 555
1 Apr 2012
Lefaivre KA Slobogean GP Valeriote J O’Brien PJ Macadam SA

We performed a systematic review of the literature to evaluate the use and interpretation of generic and disease-specific functional outcome instruments in the reporting of outcome after the surgical treatment of disruptions of the pelvic ring. A total of 28 papers met our inclusion criteria, with eight reporting only generic outcome instruments, 13 reporting only pelvis-specific outcome instruments, and six reporting both. The Short-Form 36 (SF-36) was by far the most commonly used generic outcome instrument, used in 12 papers, with widely variable reporting of scores. The pelvis-specific outcome instruments were used in 19 studies; the Majeed score in ten, Iowa pelvic score in six, Hannover pelvic score in two and the Orlando pelvic score in one. Four sets of authors, all testing construct validity based on correlation with the SF-36, performed psychometric testing of three pelvis-specific instruments (Majeed, IPS and Orlando scores). No testing of responsiveness, content validity, criterion validity, internal consistency or reproducibility was performed.

The existing literature in this area is inadequate to inform surgeons or patients in a meaningful way about the functional outcomes of these fractures after fixation.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 5 | Pages 627 - 631
1 May 2009
Khurana A Guha AR Mohanty K Ahuja S

We reviewed 15 consecutive patients, 11 women and four men, with a mean age of 48.7 years (37.3 to 62.6), who between July 2004 and August 2007 had undergone percutaneous sacroiliac fusion using hollow modular anchorage screws filled with demineralised bone matrix.

Each patient was carefully assessed to exclude other conditions and underwent pre-operative CT and MR scans. The diagnosis of symptomatic sacroiliac disease was confirmed by an injection of local anaesthetic and steroid under image intensifier control.

The short form-36 questionnaire and Majeed’s scoring system were used for pre- and post-operative functional evaluation. Post-operative radiological evaluation was performed using plain radiographs.

Intra-operative blood loss was minimal and there were no post-operative clinical or radiological complications. The mean follow-up was for 17 months (9 to 39). The mean short form-36 scores improved from 37 (23 to 51) to 80 (67 to 92) for physical function and from 53 (34 to 73) to 86 (70 to 98) for general health (p = 0.037). The mean Majeed’s score improved from 37 (18 to 54) pre-operatively to 79 (63 to 96) post-operatively (p = 0.014). There were 13 good to excellent results. The remaining two patients improved in short form-36 from a mean of 29 (26 to 35) to 48 (44 to 52). Their persistent pain was probably due to concurrent lumbar pathology.

We conclude that percutaneous hollow modular anchorage screws are a satisfactory method of achieving sacroiliac fusion.