The aim of this study was to investigate the agreement in interpretation of the quality of the paediatric hip ultrasound examination, the reliability of geometric and morphological assessment, and the relationship between these measurements. Four investigators evaluated 60 hip ultrasounds and assessed their quality based the standard plane of Graf et al. They measured geometric parameters, described the morphology of the hip, and assigned the Graf grade of dysplasia. They analyzed one self-selected image and one randomly selected image from the ultrasound series, and repeated the process four weeks later. The intra- and interobserver agreement, and correlations between various parameters were analyzed.Aims
Methods
Aims. The aim of this study was to develop and evaluate machine-learning-based computerized adaptive tests (CATs) for the Oxford Hip Score (OHS), Oxford Knee Score (OKS), Oxford Shoulder Score (OSS), and the Oxford Elbow Score (OES) and its subscales. Methods. We developed CAT algorithms for the OHS, OKS, OSS, overall OES, and each of the OES subscales, using responses to the full-length questionnaires and a machine-learning technique called regression tree learning. The algorithms were evaluated through a series of simulation studies, in which they aimed to predict respondents’ full-length questionnaire scores from only a selection of their item responses. In each case, the total number of items used by the CAT algorithm was recorded and CAT scores were compared to full-length questionnaire scores by mean, SD, score distribution plots, Pearson’s
Aims. Reimers migration percentage (MP) is a key measure to inform decision-making around the management of hip displacement in cerebral palsy (CP). The aim of this study is to assess validity and inter- and intra-rater reliability of a novel method of measuring MP using a smart phone app (HipScreen (HS) app). Methods. A total of 20 pelvis radiographs (40 hips) were used to measure MP by using the HS app. Measurements were performed by five different members of the multidisciplinary team, with varying levels of expertise in MP measurement. The same measurements were repeated two weeks later. A senior orthopaedic surgeon measured the MP on picture archiving and communication system (PACS) as the gold standard and repeated the measurements using HS app. Pearson’s
Aims. The aim of the study was to determine if there was a direct correlation between the pain and disability experienced by patients and size of their disc prolapse, measured by the disc’s cross-sectional area on T2 axial MRI scans. Methods. Patients were asked to prospectively complete visual analogue scale (VAS) and Oswestry Disability Index (ODI) scores on the day of their MRI scan. All patients with primary disc herniation were included. Exclusion criteria included recurrent disc herniation, cauda equina syndrome, or any other associated spinal pathology. T2 weighted MRI scans were reviewed on picture archiving and communications software. The T2 axial image showing the disc protrusion with the largest cross sectional area was used for measurements. The area of the disc and canal were measured at this level. The size of the disc was measured as a percentage of the cross-sectional area of the spinal canal on the chosen image. The VAS leg pain and ODI scores were each correlated with the size of the disc using the Pearson
Aims. The Single Assessment Numerical Evalution (SANE) score is a pragmatic alternative to longer patient-reported outcome measures (PROMs). The purpose of this study was to investigate the concurrent validity of the SANE and hip-specific PROMs in a generalized population of patients with hip pain at a single timepoint upon initial visit with an orthopaedic surgeon who is a hip preservation specialist. We hypothesized that SANE would have a strong correlation with the 12-question International Hip Outcome Tool (iHOT)-12, the Hip Outcome Score (HOS), and the Hip disability and Osteoarthritis Outcome Score (HOOS), providing evidence for concurrent validity of the SANE and hip-specific outcome measures in patients with hip pain. Methods. This study was a cross-sectional retrospective database analysis at a single timepoint. Data were collected from 2,782 patients at initial evaluation with a hip preservation specialist using the iHOT-12, HOS, HOOS, and SANE. Outcome scores were retrospectively analyzed using Pearson
Aims. The aim of this study was to compare patient-reported outcome measures (PROMs) and the Single Assessment Numerical Evaluation (SANE) score in patients treated with a volar locking plate for a distal radial fracture. Methods. This study was a retrospective review of a prospective database of 155 patients who underwent internal fixation with a volar locking plate for a distal radial fracture between August 2014 and April 2017. Data which were collected included postoperative PROMs (Disabilities of the Arm, Shoulder, and Hand questionnaire (DASH) and Patient-Rated Wrist Evaluation (PRWE)), and SANE scores at one month (n = 153), two months (n = 155), three months (n = 144), six months (n = 128), and one year (n = 73) after operation. Patients with incomplete data were excluded from this study. Correlation and agreement between PROMs and SANE scores were evaluated. Subgroup analyses were carried out to identify correlations according to variables such as age, the length of follow-up, and subcategories of the PRWE score. Results. The Pearson
Aims. We aimed to assess the reliability and validity of OpenPose, a posture estimation algorithm, for measurement of knee range of motion after total knee arthroplasty (TKA), in comparison to radiography and goniometry. Methods. In this prospective observational study, we analyzed 35 primary TKAs (24 patients) for knee osteoarthritis. We measured the knee angles in flexion and extension using OpenPose, radiography, and goniometry. We assessed the test-retest reliability of each method using intraclass correlation coefficient (1,1). We evaluated the ability to estimate other measurement values from the OpenPose value using linear regression analysis. We used intraclass correlation coefficients (2,1) and Bland–Altman analyses to evaluate the agreement and error between radiography and the other measurements. Results. OpenPose had excellent test-retest reliability (intraclass
Aims. Assessment of bone mineral density (BMD) with dual-energy X-ray absorptiometry (DXA) is a well-established clinical technique, but it is not available in the acute trauma setting. Thus, it cannot provide a preoperative estimation of BMD to help guide the technique of fracture fixation. Alternative methods that have been suggested for assessing BMD include: 1) cortical measures, such as cortical ratios and combined cortical scores; and 2) aluminium grading systems from preoperative digital radiographs. However, limited research has been performed in this area to validate the different methods. The aim of this study was to investigate the evaluation of BMD from digital radiographs by comparing various methods against DXA scanning. Methods. A total of 54 patients with distal radial fractures were included in the study. Each underwent posteroanterior (PA) and lateral radiographs of the injured wrist with an aluminium step wedge. Overall 27 patients underwent routine DXA scanning of the hip and lumbar spine, with 13 undergoing additional DXA scanning of the uninjured forearm. Analysis of radiographs was performed on ImageJ and Matlab with calculations of cortical measures, cortical indices, combined cortical scores, and aluminium equivalent grading. Results. Cortical measures showed varying correlations with the forearm DXA results (range: Pearson
Aims. This study aims to answer the following questions in patients with hip osteoarthritis (OA) who underwent total hip arthroplasty (THA): are patient-reported outcome measures (PROMs) affected by the location of the maximum severity of pain?; are PROMs affected by the presence of non-groin pain?; are PROMs affected by the severity of pain?; and are PROMs affected by the number of pain locations?. Methods. We reviewed 336 hips (305 patients) treated with THA for hip OA from December 2016 to November 2019 using pain location/severity questionnaires, modified Harris Hip Score (mHHS), Hip Outcome Score (HOS), international Hip Outcome Tool (iHOT-12) score, and radiological analysis. Descriptive statistics, analysis of covariance (ANCOVA), and Spearman partial
Aims. Accurate identification of the ankle joint centre is critical for estimating tibial coronal alignment in total knee arthroplasty (TKA). The purpose of the current study was to leverage artificial intelligence (AI) to determine the accuracy and effect of using different radiological anatomical landmarks to quantify mechanical alignment in relation to a traditionally defined radiological ankle centre. Methods. Patients with full-limb radiographs from the Osteoarthritis Initiative were included. A sub-cohort of 250 radiographs were annotated for landmarks relevant to knee alignment and used to train a deep learning (U-Net) workflow for angle calculation on the entire database. The radiological ankle centre was defined as the midpoint of the superior talus edge/tibial plafond. Knee alignment (hip-knee-ankle angle) was compared against 1) midpoint of the most prominent malleoli points, 2) midpoint of the soft-tissue overlying malleoli, and 3) midpoint of the soft-tissue sulcus above the malleoli. Results. A total of 932 bilateral full-limb radiographs (1,864 knees) were measured at a rate of 20.63 seconds/image. The knee alignment using the radiological ankle centre was accurate against ground truth radiologist measurements (inter-class
Aims. This study investigates the use of the metabolic equivalent of task (MET) score in a young hip arthroplasty population, and its ability to capture additional benefit beyond the ceiling effect of conventional patient-reported outcome measures. Methods. From our electronic database of 751 hip arthroplasty procedures, 221 patients were included. Patients were excluded if they had revision surgery, an alternative hip procedure, or incomplete data either preoperatively or at one-year follow-up. Included patients had a mean age of 59.4 years (SD 11.3) and 54.3% were male, incorporating 117 primary total hip and 104 hip resurfacing arthroplasty operations. Oxford Hip Score (OHS), EuroQol five-dimension questionnaire (EQ-5D), and the MET were recorded preoperatively and at one-year follow-up. The distribution was examined reporting the presence of ceiling and floor effects. Validity was assessed correlating the MET with the other scores using Spearman’s rank
Aims. The distal radius is a major site of osteoporotic bone loss resulting in a high risk of fragility fracture. This study evaluated the capability of a cortical index (CI) at the distal radius to predict the local bone mineral density (BMD). Methods. A total of 54 human cadaver forearms (ten singles, 22 pairs) (19 to 90 years) were systematically assessed by clinical radiograph (XR), dual-energy X-ray absorptiometry (DXA), CT, as well as high-resolution peripheral quantitative CT (HR-pQCT). Cortical bone thickness (CBT) of the distal radius was measured on XR and CT scans, and two cortical indices mean average (CBTavg) and gauge (CBTg) were determined. These cortical indices were compared to the BMD of the distal radius determined by DXA (areal BMD (aBMD)) and HR-pQCT (volumetric BMD (vBMD)). Pearson
Aims. The purpose of this study was to assess the reliability and responsiveness to hip surgery of a four-point modified Care and Comfort Hypertonicity Questionnaire (mCCHQ) scoring tool in children with cerebral palsy (CP) in Gross Motor Function Classification System (GMFCS) levels IV and V. Methods. This was a population-based cohort study in children with CP from a national surveillance programme. Reliability was assessed from 20 caregivers who completed the mCCHQ questionnaire on two occasions three weeks apart. Test-retest reliability of the mCCHQ was calculated, and responsiveness before and after surgery for a displaced hip was evaluated in a cohort of children. Results. Test-retest reliability for the overall mCCHQ score was good (intraclass
Aims. The aim of this study was to determine the prevalence and characteristics of C-reactive protein (CRP)-negative prosthetic joint infection (PJI) and evaluate the influence of the type of infecting organism on the CRP level. Patients and Methods. A retrospective analysis of all PJIs affecting the hip or knee that were diagnosed in our institution between March 2013 and December 2016 was performed. A total of 215 patients were included. Their mean age was 71 years (. sd. 11) and there were 118 women (55%). The median serum CRP levels were calculated for various species of organism and for patients with acute postoperative, acute haematogenous, and chronic infections. These were compared using the Kruskal–Wallis test, adjusting for multiple comparisons with Dunn’s test. The correlation between the number of positive cultures and serum CRP levels was estimated using Spearman
Aims. The primary objective of this study was to develop a validated classification system for assessing iatrogenic bone trauma and soft-tissue injury during total hip arthroplasty (THA). The secondary objective was to compare macroscopic bone trauma and soft-tissues injury in conventional THA (CO THA) versus robotic arm-assisted THA (RO THA) using this classification system. Methods. This study included 30 CO THAs versus 30 RO THAs performed by a single surgeon. Intraoperative photographs of the osseous acetabulum and periacetabular soft-tissues were obtained prior to implantation of the acetabular component, which were used to develop the proposed classification system. Interobserver and intraobserver variabilities of the proposed classification system were assessed. Results. The BOne trauma and Soft-Tissue Injury classification system in total Hip arthroplasty (BOSTI Hip) grades osseous acetabular trauma and periarticular muscle damage during THA. The classification system has an interclass
Aims. Joint registries classify all further arthroplasty procedures to a knee with an existing partial arthroplasty as revision surgery, regardless of the actual procedure performed. Relatively minor procedures, including bearing exchanges, are classified in the same way as major operations requiring augments and stems. A new classification system is proposed to acknowledge and describe the detail of these procedures, which has implications for risk, recovery, and health economics. Methods. Classification categories were proposed by a surgical consensus group, then ranked by patients, according to perceived invasiveness and implications for recovery. In round one, 26 revision cases were classified by the consensus group. Results were tested for inter-rater reliability. In round two, four additional cases were added for clarity. Round three repeated the survey one month later, subject to inter- and intrarater reliability testing. In round four, five additional expert partial knee arthroplasty surgeons were asked to classify the 30 cases according to the proposed revision partial knee classification (RPKC) system. Results. Four classes were proposed: PR1, where no bone-implant interfaces are affected; PR2, where surgery does not include conversion to total knee arthroplasty, for example, a second partial arthroplasty to a native compartment; PR3, when a standard primary total knee prosthesis is used; and PR4 when revision components are necessary. Round one resulted in 92% inter-rater agreement (Kendall’s W 0.97; p < 0.005), rising to 93% in round two (Kendall’s W 0.98; p < 0.001). Round three demonstrated 97% agreement (Kendall’s W 0.98; p < 0.001), with high intra-rater reliability (interclass
Aims. Patients who sustain neck of femur fractures are at high risk of malnutrition. Our intention was to assess to what extent malnutrition was associated with worse patient outcomes. Methods. A total of 1,199 patients with femoral neck fractures presented to a large UK teaching hospital over a three-year period. All patients had nutritional assessments performed using the Malnutrition Universal Screening Tool (MUST). Malnutrition risk was compared to mortality, length of hospital stay, and discharge destination using logistic regression. Adjustments were made for covariates to identify whether malnutrition risk independently affected these outcomes. Results. Inpatient mortality was 5.2% (35/678) in the group at low risk of malnutrition, 11.3% (46/408) in the medium-risk group, and 17.7% (20/113) in the high-risk group. Multivariate analysis showed each categorical increase in malnutrition risk independently predicted inpatient mortality with an odds ratio (OR) of 1.59 (95% confidence interval (CI) 1.14 to 2.21; p = 0.006). An increased mortality rate persisted at 120 days post-injury (OR 1.64, 95% CI 1.20 to 2.22; p = 0.002). There was a stepwise increase in the proportion of patients discharged to a residence offering a greater level of supported living. Multivariate analysis produced an OR of 1.34 (95% CI 1.03 to 1.75; p = 0.030) for each category of MUST score. Median length of hospital stay increased with a worse MUST score: 13.9 days (interquartile range (IQR) 8.2 to 23.8) in the low-risk group; 16.6 days (IQR 9.0 to 31.5) in the medium-risk group; and 22.8 days (IQR 10.1 to 41.1) in the high-risk group. Adjustment for covariates revealed a partial
Aims. To identify a core outcome set of postoperative radiographic measurements to assess technical skill in ankle fracture open reduction internal fixation (ORIF), and to validate these against Van der Vleuten’s criteria for effective assessment. Methods. An e-Delphi exercise was undertaken at a major trauma centre (n = 39) to identify relevant parameters. Feasibility was tested by two authors. Reliability and validity was tested using postoperative radiographs of ankle fracture operations performed by trainees enrolled in an educational trial (IRCTN 20431944). To determine construct validity, trainees were divided into novice (performed < ten cases at baseline) and intermediate groups (performed ≥ ten cases at baseline). To assess concurrent validity, the procedure-based assessment (PBA) was considered the gold standard. The inter-rater and intrarater reliability was tested using a randomly selected subset of 25 cases. Results. Overall, 235 ankle ORIFs were performed by 24 postgraduate year three to five trainees during ten months at nine NHS hospitals in England, UK. Overall, 42 PBAs were completed. The e-Delphi panel identified five ‘final product analysis’ parameters and defined acceptability thresholds: medial clear space (MCS); medial malleolar displacement (MMD); lateral malleolar displacement (LMD); tibiofibular clear space (TFCS) (all in mm); and talocrural angle (TCA) in degrees. Face validity, content validity, and feasibility were excellent. PBA global rating scale scores in this population showed excellent construct validity as continuous (p < 0.001) and categorical (p = 0.001) variables. Concurrent validity of all metrics was poor against PBA score. Intrarater reliability was substantial for all parameters (intraclass
Aims. The purpose of this study was to explore the correlation between femoral torsion and morphology of the distal femoral condyle in patients with trochlear dysplasia and lateral patellar instability. Methods. A total of 90 patients (64 female, 26 male; mean age 22.1 years (SD 7.2)) with lateral patellar dislocation and trochlear dysplasia who were awaiting surgical treatment between January 2015 and June 2019 were retrospectively analyzed. All patients underwent CT scans of the lower limb to assess the femoral torsion and morphology of the distal femur. The femoral torsion at various levels was assessed using the a) femoral anteversion angle (FAA), b) proximal and distal anteversion angle, c) angle of the proximal femoral axis-anatomical epicondylar axis (PFA-AEA), and d) angle of the AEA–posterior condylar line (AEA-PCL). Representative measurements of distal condylar length were taken and parameters using the ratios of the bianterior condyle, biposterior condyle, bicondyle, anterolateral condyle, and anteromedial condyle were calculated and correlated with reference to the AEA, using the Pearson
Aims. We quantitatively compared the 3D bone density distributions on CT scans performed on scaphoid waist fractures subacutely that went on to union or nonunion, and assessed whether 2D CT evaluations correlate with 3D bone density evaluations. Methods. We constructed 3D models from 17 scaphoid waist fracture CTs performed between four to 18 weeks after fracture that did not unite (nonunion group), 17 age-matched scaphoid waist fracture CTs that healed (union group), and 17 age-matched control CTs without injury (control group). We measured the 3D bone density for the distal and proximal fragments relative to the triquetrum bone density and compared findings among the three groups. We then performed bone density measurements using 2D CT and evaluated the correlation with 3D bone densities. We identified the optimal cutoff with diagnostic values of the 2D method to predict nonunion with receiver operating characteristic (ROC) curves. Results. In the nonunion group, both the distal (100.2%) and proximal (126.6%) fragments had a significantly higher bone density compared to the union (distal: 85.7%; proximal: 108.3%) or control groups (distal: 91.6%; proximal: 109.1%) using the 3D bone density measurement, which were statistically significant for all comparisons. 2D measurements were highly correlated to 3D bone density measurements (Spearman’s