Advertisement for orthosearch.org.uk
Results 1 - 50 of 351
Results per page:
Bone & Joint Research
Vol. 6, Issue 3 | Pages 144 - 153
1 Mar 2017
Kharwadkar N Mayne B Lawrence JE Khanduja V

Objectives. Bisphosphonates are widely used as first-line treatment for primary and secondary prevention of fragility fractures. Whilst they have proved effective in this role, there is growing concern over their long-term use, with much evidence linking bisphosphonate-related suppression of bone remodelling to an increased risk of atypical subtrochanteric fractures of the femur (AFFs). The objective of this article is to review this evidence, while presenting the current available strategies for the management of AFFs. Methods. We present an evaluation of current literature relating to the pathogenesis and treatment of AFFs in the context of bisphosphonate use. Results. Six broad themes relating to the pathogenesis and management of bisphosphonate-related AFFs are presented. The key themes in fracture pathogenesis are: bone microdamage accumulation; altered bone mineralisation and altered collagen formation. The key themes in fracture management are: medical therapy and surgical therapy. In addition, primary prevention strategies for AFFs are discussed. Conclusions. This article presents current knowledge about the relationship between bisphosphonates and the development of AFFs, and highlights key areas for future research. In particular, studies aimed at identifying at-risk subpopulations and organising surveillance for those on long-term therapy will be crucial in both increasing our understanding of the condition, and improving population outcomes. Cite this article: N. Kharwadkar, B. Mayne, J. E. Lawrence, V. Khanduja. Bisphosphonates and atypical subtrochanteric fractures of the femur. Bone Joint Res 2017;6:144–153. DOI: 10.1302/2046-3758.63.BJR-2016-0125.R1


Bone & Joint 360
Vol. 13, Issue 5 | Pages 39 - 42
1 Oct 2024

The October 2024 Trauma Roundup360 looks at: Early versus delayed weightbearing following operatively treated ankle fracture (WAX): a non-inferiority, multicentre, randomized controlled trial; The effect of early weightbearing and later weightbearing rehabilitation interventions on outcomes after ankle fracture surgery; Is intramedullary nailing of femoral diaphyseal fractures in the lateral decubitus position as safe and effective as on a traction table?; Periprosthetic fractures of the hip: Back to the Future, Groundhog Day, and horses for courses; Two big bones, one big decision: when to fix bilateral femur fractures; Comparison of ankle fracture fixation using intramedullary fibular nailing versus plate fixation; Unclassified acetabular fractures: do they really exist?


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 26 - 30
1 Jan 2006
Lindahl H Malchau H Odén A Garellick G

Periprosthetic fracture of the femur is an uncommon complication after total hip replacement, but appears to be increasing. We undertook a nationwide observational study to determine the risk factors for failure after treatment of these fractures, examining patient- and implant-related factors, the classification of the fractures and the outcome. Between 1979 and 2000, 1049 periprosthetic fractures of the femur were reported to the Swedish National Hip Arthroplasty Register. Of these, 245 had a further operation after failure of their initial management. Data were collected from the Register and hospital records. The material was analysed by the use of Poisson regression models. It was found that the risk of failure of treatment was reduced for Vancouver type B2 injuries (p = 0.0053) if revision of the implant was undertaken (p = 0.0033) or revision and open reduction and internal fixation (p = 0.0039) were performed. Fractures classified as Vancouver type B1 had a significantly higher risk of failure (p = 0.0001). The strongest negative factor was the use of a single plate for fixation (p = 0.001). The most common reasons for failure in this group were loosening of the femoral prosthesis, nonunion and re-fracture. It is probable that many fractures classified as Vancouver type B1 (n = 304), were in reality type B2 fractures with a loose stem which were not recognised. Plate fixation was inadequate in these cases. The difficulty in separating type B1 from type B2 fractures suggests that the prosthesis should be considered as loose until proven otherwise


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1361 - 1366
1 Oct 2006
Moroz LA Launay F Kocher MS Newton PO Frick SL Sponseller PD Flynn JM

Between 1996 and 2003 six institutions in the United States and France contributed a consecutive series of 234 fractures of the femur in 229 children which were treated by titanium elastic nailing. Minor or major complications occurred in 80 fractures. Full information was available concerning 230 fractures, of which the outcome was excellent in 150 (65%), satisfactory in 57 (25%), and poor in 23 (10%). Poor outcomes were due to leg-length discrepancy in five fractures, unacceptable angulation in 17, and failure of fixation in one. There was a statistically significant relationship (p = 0.003) between age and outcome, and the odds ratio for poor outcome was 3.86 for children aged 11 years and older compared with those below this age. The difference between the weight of children with a poor outcome and those with an excellent or satisfactory outcome was statistically significant (54 kg vs 39 kg; p = 0.003). A poor outcome was five times more likely in children who weighed more than 49 kg


The Journal of Bone & Joint Surgery British Volume
Vol. 60-B, Issue 4 | Pages 510 - 515
1 Nov 1978
Fraser R Hunter G Waddell J

The hospital records of 222 cases of ipsilateral fractures of the femur and tibia were reviewed, and patients were grouped according to the type of fracture and the method of treatment. Thirty-five per cent of patients required late operation for delayed union or non-union, osteomyelitis, refracture and malunion, regardless of the treatment group. A disturbing factor was the 30% incidence of osteomyelitis in patients treated by fixation of both fractures, almost three times the incidence when only one fracture was fixed. A 30% incidence of delayed union or non-union occurred in patients managed conservatively. Of sixty-three patients personally examined, the worst results found were those following conservative management of both fractures. More use of rigid external fixation and of cast bracing is recommended in the management of the fractured tibia, combined with internal fixation of the femoral fracture. Examination of the knee suggested that, with ipsilateral fractures, disruption of ligaments is a common occurrence and should always be suspected


The Journal of Bone & Joint Surgery British Volume
Vol. 58-B, Issue 1 | Pages 2 - 24
1 Feb 1976
Barnes R Brown J Garden R Nicoll E

This abridged account of a report to the British Medical Research Council describes a long-term investigation of 1,503 subcapital fractures of the femur, almost all of which were treated by reduction and internal fixation. With three exceptions, union occurred in all Garden Stage I and Stage II fractures and in 67% of Stage III and Stage IV fractures, of which only 14-5% were united at six months. In women, late segmental collapse was seen after union had occurred in 16% of Stage I and in 27-6% of Stage III and Stage IV fractures. Delay of up to one week before operation had no significant effect on the incidence of non-union or of late segmental collapse. The incidence of union followed by late segmental collapse was higher in women with normal bone density than in those with osteoporosis. Smith-Petersen nailing was found to be the least effective form of fixation in displaced fractures. The age and physical state of the patient, the accuracy of reduction, and the security of fixation had the greatest influence on union


The Journal of Bone & Joint Surgery British Volume
Vol. 47-B, Issue 3 | Pages 510 - 513
1 Aug 1965
Roper BA Provan JL

1. A case of femoral artery occlusion after fracture of the femur occurring several days after internal fixation with a medullary nail is described. 2. Arterial reconstruction was undertaken seventeen days after the internal fixation, twenty-seven days after the injury, with restoration of flow and recovery of the limb


The Journal of Bone & Joint Surgery British Volume
Vol. 33-B, Issue 3 | Pages 336 - 347
1 Aug 1951
Thomson SA Mahoney LJ

1. Volkmann’s ischaemia is a real and threatening complication of fracture of the femur, and it is more common than reports in the literature would suggest. 2. The early signs and symptoms in the calf are ominous whereas the early vascular signs of a good tibial pulse, colour and temperature are often misleading. 3. Muscle decompression with or without arterial exploration has proved to be of no value. 4. Early recognition and radical treatment are imperative. Temporary paralysis of the lumbar sympathetic outflow has been shown to be an effective measure. 5. Transfixion of the calcaneum with a Kirschner wire for traction has the advantage of eliminating all bandages, suspending the tender calf and preventing an equinovarus deformity. 6. The only essential difference between the histological appearance of muscle which recovers and that which does not appears to be degeneration of muscle nuclei. The significance of engorged blood vessels remains in doubt. 7. Histological studies suggest that despite the typical gross appearance of an infarct some regeneration of muscle may occur


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 1 | Pages 78 - 82
1 Jan 1986
Skinner P Powles D

We report a prospective study of 198 cases of subcapital fracture of the femur treated by closed reduction and fixation with a sliding compression screw-plate. This was done without regard to the patient's age or the Garden stage of the fracture. Early weight-bearing was encouraged. Of the displaced fractures 23% failed in the first year because of non-union or infection. Of the fractures which united 27% had developed avascular necrosis after three years. Despite this we believe that the sliding compression screw-plate, of proven value in the treatment of intertrochanteric fractures, is also useful for the fixation of subcapital fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1347 - 1350
1 Oct 2006
Karn NK Singh GK Kumar P Shrestha B Singh MP Gowda MJ

We conducted a randomised controlled trial to compare external fixation of trochanteric fractures of the femur with the more costly option of the sliding hip screw. Patients in both groups were matched for age (mean 67 years, 50 to 100) and gender. We excluded all pathological fractures, patients presenting at more than one week, fractures with subtrochanteric extension or reverse obliquity, multiple fractures or any bone and joint disease interfering with rehabilitation. The interval between injury and operation, the duration of surgery, the amount of blood loss, the length of hospital stay and the cost of treatment were all significantly higher in the sliding hip screw group (p < 0.05). The time to union, range of movement, mean Harris hip scores and Western Ontario and McMaster University knee scores were comparable at six months. The number of patients showing shortening or malrotation was too small to show a significant difference between the groups. Pin-track infection occurred in 18 patients (60%) treated with external fixation, whereas there was a single case of wound infection (3.3%) in the sliding hip screw group


The Journal of Bone & Joint Surgery British Volume
Vol. 50-B, Issue 3 | Pages 562 - 569
1 Aug 1968
Graham J

1. A report is presented of the results of a trial to compare the effects of early and late weight-bearing in patients with a transcervical fracture of the femur treated by reduction of the fracture and internal fixation with a sliding nail-plate. 2. One hundred and twelve patients have been assessed clinically and radiologically three years after operation. 3. Retrospective analysis of factors that affect the outcome of treatment suggests that the two groups were fairly evenly balanced. 4. The results show that full weight-bearing two weeks after operation did not increase the incidence of failure of fixation or of non-union. 5. The higher incidence of superior segmental collapse in patients in whom weight-bearing was deferred for twelve weeks can be explained by the greater number of high fractures in this group and the greater number with a poor reduction


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 4 | Pages 527 - 534
1 Apr 2010
Streubel PN Gardner MJ Morshed S Collinge CA Gallagher B Ricci WM

It is unclear whether there is a limit to the amount of distal bone required to support fixation of supracondylar periprosthetic femoral fractures. This retrospective multicentre study evaluated lateral locked plating of periprosthetic supracondylar femoral fractures and compared the results according to extension of the fracture distal with the proximal border of the femoral prosthetic component. Between 1999 and 2008, 89 patients underwent lateral locked plating of a supracondylar periprosthetic femoral fracture, of whom 61 patients with a mean age of 72 years (42 to 96) comprising 53 women, were available after a minimum follow-up of six months or until fracture healing. Patients were grouped into those with fractures located proximally (28) and those with fractures that extended distal to the proximal border of the femoral component (33). Delayed healing and nonunion occurred respectively in five (18%) and three (11%) of more proximal fractures, and in two (6%) and five (15%) of the fractures with distal extension (p = 0.23 for delayed healing; p = 0.72 for nonunion, Fisher’s exact test). Four construct failures (14%) occurred in more proximal fractures, and three (9%) in fractures with distal extension (p = 0.51). Of the two deep infections that occurred in each group, one resolved after surgical debridement and antibiotics, and one progressed to a nonunion. Extreme distal periprosthetic supracondylar fractures of the femur are not a contra-indication to lateral locked plating. These fractures can be managed with internal fixation, with predictable results, similar to those seen in more proximal fractures


The Bone & Joint Journal
Vol. 99-B, Issue 3 | Pages 291 - 294
1 Mar 2017
Javaid MK Handley R Costa ML


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 4 | Pages 557 - 560
1 Aug 1986
Esser M Kassab J Jones D

In a randomised prospective trial 98 elderly women with trochanteric fractures of the femur were treated with either a 135 degrees Jewett nail-plate or a 135 degrees Dynamic hip screw. The results at six weeks, three months and six months were statistically analysed. There were no significant differences in the two groups with regard to pain, length of hospital stay, morbidity or mortality. Although operative difficulties and open reduction were more common with the Dynamic hip screw, at the end of six months more patients in this group were mobile and there was significant radiological evidence of better compression without loss of fixation


The Journal of Bone & Joint Surgery British Volume
Vol. 55-B, Issue 2 | Pages 312 - 318
1 May 1973
Christensen NO

1. The Küntscher method of intramedullary reaming and nail fixation was applied to thirty-five cases of non-union of the lower extremity, twenty femurs and fifteen tibias. A bone graft was generally not used. 2. Most of the patients were allowed to bear weight and to exercise the joints within a few days of the operation. Additional measures such as pre-operative surgery for infection or distraction of shortening were used in some cases. 3. The pseudarthrosis healed in all cases, even when infection was present. The nails were generally not removed until after healing had occurred. 4. It is concluded that the Küntscher method gives remarkably rapid consolidation and restoration of function even in difficult cases of non-union of shaft fracture, particularly of the femur


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 6 | Pages 891 - 892
1 Nov 1997
Macnicol MF


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 8 | Pages 1100 - 1104
1 Nov 2004
Jaarsma RL van Kampen A


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 4 | Pages 639 - 643
1 Aug 1988
Greenough C Jones

The results of primary total hip arthroplasty for sub-capital femoral neck fracture in previously normal hips are reported. Thirty-seven patients aged 70 or less at the time of surgery were reviewed at an average follow-up of 56 months. Eighteen (49%) had undergone or were awaiting revision surgery. A further four (11%) had definite radiological signs of loosening. Harris hip scores were calculated and correlated well with the results of gait analysis; these suggested that it was the more vigorous patients that were more liable to early failure. Consequently, primary total hip replacement is not recommended for subcapital fractures in the younger patient without pre-existing hip pathology.


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 2 | Pages 214 - 217
1 Mar 1985
Taine W Armour P

The management of displaced subcapital fracture of the hip is still controversial because of the high incidence of complications after internal fixation or hemiarthroplasty. To avoid some of these complications we have used primary total hip replacement for independently mobile patients over 65 years of age. A total of 163 cases, operated on over four years, have been reviewed. There were relatively more dislocations after operation for fracture than after total replacement for arthritis, and these were associated with a posterior approach to the hip. Only seven revision operations have been required. Of 57 patients who were interviewed an average of 42 months after replacement, 62% had excellent or good results as assessed by the Harris hip score. All the others had major systemic disease which affected their assessment. This inadequacy of current systems of hip assessment is discussed. It is concluded that total hip replacement is the best management for a selected group of patients with this injury, and that further prospective studies are indicated.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 11 | Pages 1424 - 1430
1 Nov 2009
Corten K Vanrykel F Bellemans J Frederix PR Simon J Broos PLO

The use of plate-and-cable constructs to treat periprosthetic fractures around a well-fixed femoral component in total hip replacements has been reported to have high rates of failure. Our aim was to evaluate the results of a surgical treatment algorithm to use these lateral constructs reliably in Vancouver type-B1 and type-C fractures. The joint was dislocated and the stability of the femoral component was meticulously evaluated in 45 type-B1 fractures. This led to the identification of nine (20%) unstable components. The fracture was considered to be suitable for single plate-and-cable fixation by a direct reduction technique if the integrity of the medial cortex could be restored.

Union was achieved in 29 of 30 fractures (97%) at a mean of 6.4 months (3 to 30) in 29 type-B1 and five type-C fractures. Three patients developed an infection and one construct failed.

Using this algorithm plate-and-cable constructs can be used safely, but indirect reduction with minimal soft-tissue damage could lead to shorter times to union and lower rates of complications.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 7 | Pages 954 - 957
1 Sep 2004
Metaizeau J

Fractures of the femur are the most incapacitating fractures in children. Conservative treatment necessitates a long stay in hospital for traction and subsequent immobilisation in an uncomfortable cast. This treatment is not well tolerated, especially in adolescents. Moreover, near the end of growth, accurate reduction is necessary, as malunion is no longer correctable by growth. Stable elastic intramedullary nailing uses two flexible nails which are introduced percutaneously either through the lower metaphysis or the subtrochanteric area. This technique does not disturb the healing of the fracture. The elasticity of the device allows slight movement at the fracture site which favours union. Reduction and stabilisation are adequate and the operative risk is very low. A cast is not required, functional recovery is rapid and the patient is allowed to walk with crutches after seven to ten days according to the type of fracture. This technique is very efficient in adolescents and can be used after the age of seven years when conservative treatment is unsuccessful.


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 1 | Pages 23 - 25
1 Jan 1990
Sojbjerg J Eiskjaer S Moller-Larsen F

Forty comminuted or unstable fractures of the femoral shaft were treated by closed intramedullary reaming and locked nailing. Twenty-four fractures were severely comminuted, and the other 16, in the distal or proximal third of the shaft, were classified as unstable. At 12 to 30 months postoperatively all the fractures had healed. Three patients had lateral rotation deformity of 5 degrees to 10 degrees, three had shortening of 1 to 2 cm and two had lengthening of about 1 cm. There were no infections or delayed unions. Closed intramedullary locked nailing can provide stability in fractures of the femoral shaft, irrespective of the degree of comminution and the site of injury.


The Journal of Bone & Joint Surgery British Volume
Vol. 45-B, Issue 2 | Pages 344 - 345
1 May 1963
Bonney G


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 2 | Pages 195 - 198
1 Mar 1988
Crawfurd E Emery R Hansell D Phelan M Andrews B

It has been shown that raised intracapsular pressure causes avascular necrosis of the femoral head in experimental animals, but the relevance of this to clinical fractures of the femoral neck is controversial. We have studied 19 patients with intracapsular fractures of the femoral neck by pressure measurement and by ultrasonography to demonstrate capsular distension. The intra-articular pressure in Garden Grade I and II fractures averaged 66.4 mmHg with a maximum of 145 mmHg. In 10 Garden Grade III and IV fractures the average pressure was 28 mmHg with a maximum of 65 mmHg. Most of the recorded intracapsular pressures were high enough to have caused possible vascular embarrassment, and it is suggested that early decompression of the haemarthrosis should be considered.


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 4 | Pages 655 - 656
1 Aug 1986
Barton N


The Journal of Bone & Joint Surgery British Volume
Vol. 62-B, Issue 1 | Pages 12 - 17
1 Feb 1980
Dove J

Complete fractures through bone affected by Paget's disease may not deserve their innocent reputation. This retrospective study of 182 such femoral fractures, the largest reported series to date, was carried out to discover the behaviour of these fractures in the absence of specific therapy for the Paget's disease. Most previous series have concluded that healing is uneventful but the findings in these patients from the West Midlands do not bear this out. After exclusion of the early deaths, the overall incidence of non-union was 40 per cent, the main problems being posed by the subtrochanteric fractures and those of the upper shaft. Although callus may be abundant, it may itself be involved in the disease process and is not a reliable sign of union. Based on these observations, suggestions for management in the different regions of the femur are made.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1488 - 1494
1 Nov 2007
Gorodetskyi IG Gorodnichenko AI Tursin PS Reshetnyak VK Uskov ON

We undertook a trial on 60 patients with AO 31A2 fractures of the hip who were randomised after stabilisation of the fracture into two equal groups, one of which received post-operative treatment using a non-invasive interactive neurostimulation device and the other with a sham device. All other aspects of their rehabilitation were the same. The treatment was continued for ten days after operation.

Outcome measurements included the use of a visual analogue scale for pain, the brief pain inventory and Ketorolac for post-operative control of pain, and an overall assessment of outcome by the surgeon. There were significantly better results for the patients receiving treatment by active electrical stimulation (repeated measures analysis of variance, p < 0.001). The findings of this pilot trial justify a larger study to determine if these results are more generally applicable.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 23 - 29
1 Jan 2002
Vossinakis IC Badras LS

In a prospective, randomised study we have compared the pertrochanteric external fixator (PF) with the sliding hip screw (SHS) in 100 consecutive patients who were allocated randomly to the two methods of treatment. Details of the patients and the patterns of fracture were similar in both groups. Follow-up was for six months.

Use of the PF was associated with significantly less blood loss, a shorter operating time, reduced postoperative pain, shorter hospitalisation (p < 0.001), earlier mobilisation (p < 0.001) and a reduced rate of mechanical complications (p < 0.01). Superficial infection was significantly more common with the PF (p < 0.01), but without long-term adverse consequences. There were no differences in the healing of the fracture, mortality or final functional outcome. Our results indicate that the external fixator is an effective and safe device for treating pertrochanteric fractures and should be considered as a useful alternative to conventional fixation with the sliding hip screw.


The Journal of Bone & Joint Surgery British Volume
Vol. 46-B, Issue 2 | Pages 204 - 205
1 May 1964
Abrami G Stevens J

1 . A preliminary report is presented of a clinical trial to compare the results of early and late weight bearing in randomly selected patients of comparable age groups whose displaced femoral neck fractures were treated by internal fixation with a sliding nail-plate.

2. When 124 patients were assessed at three months and 107 at six months after operation there was no significant difference between those who started unguarded weight bearing two weeks after operation and those who avoided weight bearing for three months.

3. Early weight bearing appears to have no harmful effect on the early post-operative stability of this fracture when a sliding nail-plate is used for fixation.

4. Further information is necessary before any conclusion can be reached about the effect of early weight bearing on the ultimate fate of the fracture and of the femoral head. For this reason, and also to increase the numbers of patients in the series, the trial is continuing and the patients are being followed up for a three-year period.


The Bone & Joint Journal
Vol. 98-B, Issue 6 | Pages 846 - 850
1 Jun 2016
Hoskins W Sheehy R Edwards ER Hau RC Bucknill A Parsons N Griffin XL

Aims. Fractures of the distal femur are an important cause of morbidity. Their optimal management remains controversial. Contemporary implants include angular-stable anatomical locking plates and locked intramedullary nails (IMNs). We compared the long-term patient-reported functional outcome of fixation of fractures of the distal femur using these two methods of treatment. Patients and Methods. A total of 297 patients were retrospectively identified from a State-wide trauma registry in Australia: 195 had been treated with a locking plate and 102 with an IMN. Baseline characteristics of the patients and their fractures were recorded. Health-related quality-of-life, functional and radiographic outcomes were compared using mixed effects regression models at six months and one year. Results. There was a clinically relevant and significant difference in quality-of-life at six months in favour of fixation with an IMN (mean difference in EuroQol-5 Dimensions Score (EQ-5D) = 0.12; 95% CI 0.02 to 0.22; p = 0.025). There was weak evidence that this trend continued to one year (mean difference EQ-5D = 0.09; 95% CI -0.01 to 0.19; p = 0.073). There was a significant although very small reduction in angular deformity using an IMN (mean difference -1.02; 95% CI -1.99 to -0.06; p = 0.073). There was no evidence that there was a difference in any other outcomes at any time point. Take home message: IMN may be a superior treatment compared with anatomical locking plates for fractures of the distal femur. These findings are concordant with other data from pilot randomised studies which favour treatment of these fractures with an IMN. This study strongly supports the need for a definitive randomised trial. Cite this article: Bone Joint J 2016;98-B:846–50


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 4 | Pages 619 - 623
1 Aug 1989
Hornby R Evans J Vardon V

All elderly patients with extracapsular hip fractures seen in hospitals in Newcastle upon Tyne over a 12-month period were studied and followed up for six months. At one of the hospitals, patients were randomised to treatment by AO dynamic hip-screw or by traction. Complications specific to the two treatments were low, and general complications, six-month mortality and prevalence of pain, leg swelling and unhealed sores, showed no difference between the two modes of treatment. Operative treatment gave better anatomical results and a shorter hospital stay, but significantly more of the patients treated by traction showed loss of independence six months after injury.


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 3 | Pages 357 - 361
1 Aug 1981
Sikorski J Barrington R

A prospective randomised trial of surgical treatment for the displaced subcapital femoral fracture in patients of 70 years or more is presented. Two hundred and eighteen patients were randomly allocated into one of three treatment groups: manipulative reduction and internal fixation using Garden screws; Thompson hemiarthroplasty through a posterior (Moore) approach; and Thompson hemiarthroplasty through an anterolateral (McKee) approach. There is no significant difference in the mortality of the internal fixation and posterior arthroplasty groups. Both groups showed a significantly higher mortality than patients operated on through the anterior approach. The technical results of operation were worse in the internally fixed group, with only 40 per cent being satisfactory. Mobilisation was best achieved after the posterior approach. It is concluded that Thompson hemiarthroplasty, using an anterolateral approach, is the safest operation in this group of patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 77 - 79
1 Jan 1999
Weatherall M

In three consecutive years 462 patients over the age of 60 years presented at Waikato Hospital, Hamilton, New Zealand, with a fracture of the proximal femur. Within two years, 11 (2.4%) returned with a fracture of the contralateral femur. If the effectiveness of any form of treatment aiming at reducing the incidence of contralateral fracture were subjected to a trial, a sample size of 5000, randomly distributed equally between treatment and placebo groups, would be needed for the trial to have a power of 80% to detect a reduction


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 3 | Pages 393 - 398
1 Mar 2011
Findlay JM Keogh MJ Boulton C Forward DP Moran CG

We performed a retrospective study of a departmental database to assess the efficacy of a new model of orthopaedic care on the outcome of patients with a fracture of the proximal femur. All 1578 patients admitted to a university teaching hospital with a fracture of the proximal femur between December 2007 and December 2009 were included. The allocation of Foundation doctors years 1 and 2 was restructured from individual teams covering several wards to pairs covering individual wards. No alterations were made in the numbers of doctors, their hours, out-of-hours cover, or any other aspect of standard patient care. Outcome measures comprised 30-day mortality and cause, complications and length of stay. Mortality was reduced from 11.7% to 7.6% (p = 0.007, Cox’s regression analysis); adjusted odds ratio was 1.559 (95% confidence interval 1.128 to 2.156). Reductions were seen in Clostridium difficile colitis (p = 0.017), deep wound infection (p = 0.043) and gastrointestinal haemorrhage (p = 0.033). There were no differences in any patient risk factors (except the prevalence of chronic obstructive pulmonary disease), cause of death and length of stay before and after intervention. The underlying mechanisms are unclear, but may include improved efficiency and medical contact time. These findings may have implications for all specialties caring for patients on several wards, and we believe they justify a prospective trial to further assess this effect


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 5 | Pages 794 - 796
1 Sep 1993
Anderson G Harper W Connolly C Badham J Goodrich N Gregg P

We report the results of a randomised trial to determine the effects of skin traction on 252 patients awaiting surgery for fractures of the proximal femur. They were allocated randomly to be nursed free in bed or to receive Hamilton-Russell skin traction. No differences were found between the groups in terms of pain suffered, analgesia required, frequency of pressure sores or ease of operation. The application of skin traction to patients with fractures of the upper femur is time-consuming and we recommend therefore that its routine use should be discontinued


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 5 | Pages 663 - 667
1 Jul 2001
Arazi M Memik R Ögün TC Yel M

Our aim was to determine the clinical effectiveness and safety of Ilizarov external fixation for the acute treatment of severely comminuted extra-articular and intercondylar fractures of the distal femur. A total of 14 consecutive patients with complex fractures was treated. There were three type-A3, two type-C2 and nine type-C3 fractures according to the AO/ASIF system. The mean follow-up was 14 months. Most fractures (13) united primarily at a mean of 16 weeks. One patient with a type-IIIA open fracture had infection and nonunion. The mean range of flexion of the knee at the final follow-up was 105° (35 to 130). We conclude that, in the treatment of comminuted fractures of the distal femur, the Ilizarov fixator is safe and effective in providing stability and allowing early rehabilitation


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 4 | Pages 679 - 683
1 Jul 1998
Blundell CM Parker MJ Pryor GA Hopkinson-Woolley J Bhonsle SS

There are a number of classification systems for intracapsular fractures of the proximal femur, but none has been shown to be practical with satisfactory reproducibility and accurate predictive value. We have investigated the AO classification and evaluated intra-and interobserver accuracy and its value in predicting treatment and outcome. We found it to have very poor intra- and interobserver reliability and to be of limited predictive use for the outcome of treatment. A simplified system in which the subdivisions were allocated to one of three groups of undisplaced, displaced and basal fractures was found to be of value. We conclude that this is the only division which is appropriate for these fractures and that the AO system for intracapsular fractures is too complicated and should not be used


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 2 | Pages 257 - 260
1 Mar 1992
Mont M Maar D Krackow K Hungerford D

Retrospective review of 730 consecutive primary uncemented and cemented total hip arthroplasties revealed 19 intra-operative hoop-stress fractures of the femoral neck. These were incomplete, linear, and minimally displaced. Management was by cerclage wiring (12), bone graft and cerclage (two), further impaction (two), and the use of cement (three), with no change from our standard postoperative management and rehabilitation. Eighteen patients had excellent or good results with an average Harris hip score of 93. Radiographically, all but one patient had Engh stability-fixation scores consistent with stable bone ingrowth. We conclude that hoop-stress fractures of the proximal femur, properly managed, do not detract from the results of total hip arthroplasty


Objectives. The annual incidence of hip fracture is 620 000 in the European Union. The cost of this clinical problem has been estimated at 1.75 million disability-adjusted life years lost, equating to 1.4% of the total healthcare burden in established market economies. Recent guidance from The National Institute for Health and Clinical Excellence (NICE) states that research into the clinical and cost effectiveness of total hip arthroplasty (THA) as a treatment for hip fracture is a priority. We asked the question: can a trial investigating THA for hip fracture currently be delivered in the NHS?. Methods. We performed a contemporaneous process evaluation that provides a context for the interpretation of the findings of WHiTE Two – a randomised study of THA for hip fracture. We developed a mixed methods approach to situate the trial centre within the context of wider United Kingdom clinical practice. We focused on fidelity, implementation, acceptability and feasibility of both the trial processes and interventions to stakeholder groups, such as healthcare providers and patients. Results. We have shown that patients are willing to participate in this type of research and that surgeons value being part of a team that has a strong research ethos. However, surgical practice does not currently reflect NICE guidance. Current models of service delivery for hip fractures are unlikely to be able to provide timely total hip arthroplasty for suitable patients. Conclusions. Further observational research should be conducted to define the population of interest before future interventional studies are performed. Cite this article: C. Huxley, J. Achten, M. L. Costa, F. Griffiths, X. L. Griffin. A process evaluation of the WHiTE Two trial comparing total hip arthroplasty with and without dual mobility component in the treatment of displaced intracapsular fractures of the proximal femur: Can a trial investigating total hip arthroplasty for hip fracture be delivered in the NHS? Bone Joint Res 2016;5:444–452. DOI: 10.1302/2046-3758.510.BJR-2015-0008.R1


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 4 | Pages 618 - 621
1 May 2001
MAIYA S KHAN T GRIMER RJ CARTER SR TILLMAN RM


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 4 | Pages 618 - 618
1 May 2001
HOSSAIN S PATON RW


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1669 - 1673
1 Dec 2014
Van der Merwe JM Haddad FS Duncan CP

The Unified Classification System (UCS) was introduced because of a growing need to have a standardised universal classification system of periprosthetic fractures. It combines and simplifies many existing classification systems, and can be applied to any fracture around any partial or total joint replacement occurring during or after operation. Our goal was to assess the inter- and intra-observer reliability of the UCS in association with knee replacement when classifying fractures affecting one or more of the femur, tibia or patella.

We used an international panel of ten orthopaedic surgeons with subspecialty fellowship training and expertise in adult hip and knee reconstruction (‘experts’) and ten residents of orthopaedic surgery in the last two years of training (‘pre-experts’). They each received 15 radiographs for evaluation. After six weeks they evaluated the same radiographs again but in a different order.

The reliability was assessed using the Kappa and weighted Kappa values.

The Kappa values for inter-observer reliability for the experts and the pre-experts were 0.741 (95% confidence interval (CI) 0.707 to 0.774) and 0.765 (95% CI 0.733 to 0.797), respectively. The weighted Kappa values for intra-observer reliability for the experts and pre-experts were 0.898 (95% CI 0.846 to 0.950) and 0.878 (95% CI 0.815 to 0.942) respectively.

The UCS has substantial inter-observer reliability and ‘near perfect’ intra-observer reliability when used for periprosthetic fractures in association with knee replacement in the hands of experienced and inexperienced users.

Cite this article: Bone Joint J 2014;96-B:1669–73.


The Bone & Joint Journal
Vol. 98-B, Issue 6 | Pages 840 - 845
1 Jun 2016
Chesser TJS Fox R Harding K Halliday R Barnfield S Willett K Lamb S Yau C Javaid MK Gray AC Young J Taylor H Shah K Greenwood R

Aims

We wished to assess the feasibility of a future randomised controlled trial of parathyroid hormone (PTH) supplements to aid healing of trochanteric fractures of the hip, by an open label prospective feasibility and pilot study with a nested qualitative sub study. This aimed to inform the design of a future powered study comparing the functional recovery after trochanteric hip fracture in patients undergoing standard care, versus those who undergo administration of subcutaneous injection of PTH for six weeks.

Patients and Methods

We undertook a pilot study comparing the functional recovery after trochanteric hip fracture in patients 60 years or older, admitted with a trochanteric hip fracture, and potentially eligible to be randomised to either standard care or the administration of subcutaneous PTH for six weeks. Our desired outcomes were functional testing and measures to assess the feasibility and acceptability of the study.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 3 | Pages 463 - 463
1 Apr 2002
BANNISTER G


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 2 | Pages 206 - 212
1 Mar 2001
Davison JNS Calder SJ Anderson GH Ward G Jagger C Harper WM Gregg PJ

We performed a prospective, randomised trial comparing three treatments for displaced intracapsular fractures of the hip in 280 patients aged 65 to 79 years.

The mean patient survival was significantly higher in the group undergoing reduction and internal fixation (79 months) compared with that with a cemented Thompson hemiarthroplasty or a cemented Monk bipolar hemiarthroplasty (61 months and 68 months, respectively). After three years, 32 of 93 patients (34.4%) who had undergone fixation had local complications, necessitating further intervention in 28 (30%). There were no significant differences in the functional outcome in survivors, who were reviewed annually to five years.

Either reduction and internal fixation or cemented hemiarthroplasty may be offered as alternative treatments for a displaced intracapsular fracture in a mobile and mentally competent patient under the age of 80 years. The choice of procedure by the patient and the surgeon should be determined by the realisation that the use of internal fixation is associated with a 30% risk of failure requiring further surgery. If this is accepted, however, hemiarthroplasty is avoided, which, in our study has a significantly shorter mean survival time. The use of a bipolar prosthesis has no significant advantage.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 7 | Pages 851 - 854
1 Jul 2009
Timperley AJ Whitehouse SL

Recently the National Patient Safety Agency in the United Kingdom published a report entitled “Mitigating surgical risk in patients undergoing hip arthroplasty for fractures of the proximal femur”. A total of 26 deaths had been reported to them when cement was used at hemiarthroplasty between October 2003 and October 2008. This paper considers the evidence for using cement fixation of a hemiarthroplasty in the treatment of hip fractures.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 8 | Pages 1123 - 1126
1 Aug 2005
Siegmeth AW Gurusamy K Parker MJ

Previous studies on the timing of surgery for fracture of the hip provide conflicting evidence as to the effect of prolonged delay before operation. We have prospectively reviewed 3628 such fractures in patients older than 60 years of age. Those for whom the delay was for medical reasons were excluded. Patients were followed up for one year or until death. Operation was undertaken within 48 hours in 95.2% and after this in 4.8%. A significant increase in length of stay was found in patients operated on after 48 hours when compared with those in the earlier group (21.6 vs 32.5 days). No increase in hospital stay was found for lesser delays.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 8 | Pages 1100 - 1102
1 Aug 2009
Kutty S Pettit P Powell JN

Fracture of the neck of the femur after resurfacing arthroplasty usually leads to failure and conversion to a total hip replacement. We describe an intracapsular fracture of the femoral neck sustained after hip resurfacing which was treated by cannulated screws, resulting in union and retention of the resurfacing implant. The result at follow-up three years later was very satisfactory with a Harris hip score of 99.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 148 - 149
1 Jan 2002
SCHANDELMAIER P


Bone & Joint 360
Vol. 11, Issue 6 | Pages 15 - 18
1 Dec 2022

The December 2022 Hip & Pelvis Roundup. 360. looks at: Fix and replace: simultaneous fracture fixation and hip arthroplasty for acetabular fractures in older patients; Is the revision rate for femoral neck fracture lower for total hip arthroplasty than for hemiarthroplasty?; Femoral periprosthetic fractures: data from the COMPOSE cohort study; Dual-mobility cups and fracture of the femur; What’s the deal with outcomes for hip and knee arthroplasty outcomes internationally?; Osteochondral lesions of the femoral head: is costal cartilage the answer?