header advert
Results 1 - 50 of 754
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 130 - 134
1 Jan 1999
Alfaro-Adrián J Gill HS Murray DW

Studies using roentgen stereophotogrammetric analysis (RSA) have shown that the femoral components of cemented total hip replacements (THR) migrate distally relative to the bone, but it is not clear whether this occurs at the cement-implant or the cement-bone interface or within the cement mantle. Our aim was to determine where this migration occurred, since this has important implications for the way in which implants function and fail. Using RSA we compared for two years the migration of the tip of the stem with that of the cement restrictor for two different designs of THR, the Exeter and Charnley Elite. We have assumed that if the cement restrictor migrates, then at least part of the cement mantle also migrates. Our results have shown that the Exeter migrates distally three times faster than the Charnley Elite and at different interfaces. With the Exeter migration was at the cement-implant interface whereas with the Charnley Elite there was migration at both the cement-bone and the cement-implant interfaces


Bone & Joint Research
Vol. 2, Issue 11 | Pages 248 - 254
1 Nov 2013
McHugh GA Campbell M Luker KA

Objectives. To investigate psychosocial and biomedical outcomes following total hip replacement (THR) and to identify predictors of recovery from THR. Methods. Patients with osteoarthritis (OA) on the waiting list for primary THR in North West England were assessed pre-operatively and at six and 12 months post-operatively to investigate psychosocial and biomedical outcomes. Psychosocial outcomes were anxiety and depression, social support and health-related quality of life (HRQoL). Biomedical outcomes were pain, physical function and stiffness. The primary outcome was the Short-Form 36 (SF-36) Health Survey Total Physical Function. Potential predictors of outcome were age, sex, body mass index, previous joint replacement, involvement in the decision for THR, any comorbidities, any complications, type of medication, and pre-operative ENRICHD Social Support Instrument score, Hospital Anxiety and Depression scores and Western Ontario and McMaster Universities osteoarthritis index score. Results. The study included 206 patients undergoing THR. There were 88 men and 118 women with a mean age of 66.3 years (. sd. 10.4;36 to 89). Pain, stiffness and physical function, severity of OA, HRQoL, anxiety and depression all improved significantly from pre-operative to 12-month assessment (all p < 0.001), with the greatest improvement occurring in the first six months (all p < 0.001). The predictors that were found to influence recovery six months after THR were: pain (p < 0.001), anxiety (p = 0.034), depression (p = 0.001), previous joint replacement (p = 0.006) and anti-inflammatory drugs (p = 0.012). Conclusions. The study identified the key psychosocial and biomedical predictors of recovery following THR. By identifying these predictors, we are able to identify and provide more support for patients at risk of poor recovery following THR. Cite this article: Bone Joint Res 2013;2:248–54


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 578 - 582
1 May 2013
Kim S Postigo R Koo S Kim JH

The timing of total hip replacement (THR) in patients with active tuberculosis (TB) of the hip is controversial, because of the potential risk of reactivation of infection. There is little information about the outcome of THR in these patients. We conducted a systematic review of published studies that evaluated the outcome of THR in patients with active TB of the hip. A review of multiple databases referenced articles published between 1950 and 2012. A total of six articles were identified, comprising 65 patients. TB was confirmed histologically in all patients. The mean follow-up was 53.2 months (24 to 108). Antituberculosis treatment continued post-operatively for between six and 15 months, after debridement and THR. One non-compliant patient had reactivation of infection. At the final follow-up the mean Harris hip score was 91.7 (56 to 98). We conclude that THR in patients with active TB of the hip is a safe procedure, providing symptomatic relief and functional improvement if undertaken in association with extensive debridement and appropriate antituberculosis treatment. Cite this article: Bone Joint J 2013;95-B:578–82


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1474 - 1479
1 Nov 2013
Tsang SJ Gaston P

Total hip replacement (THR) has been shown to be a cost-effective procedure. However, it is not risk-free. Certain conditions, such as diabetes mellitus, are thought to increase the risk of complications. In this study we have evaluated the prevalence of diabetes mellitus in patients undergoing THR and the associated risk of adverse operative outcomes. A meta-analysis and systematic review were conducted according to the guidelines of the meta-analysis of observational studies in epidemiology. Inclusion criteria were observational studies reporting the prevalence of diabetes in the study population, accompanied by reports of at least one of the following outcomes: venous thromboembolic events; acute coronary events; infections of the urinary tract, lower respiratory tract or surgical site; or requirement for revision arthroplasty. Altman and Bland’s methods were used to calculate differences in relative risks. The prevalence of diabetes mellitus was found to be 5.0% among patients undergoing THR, and was associated with an increased risk of established surgical site infection (odds ratio (OR) 2.04 (95% confidence interval (CI) 1.52 to 2.76)), urinary infection (OR 1.43 (95% CI 1.33 to 1.55)) and lower respiratory tract infections (OR 1.95 (95% CI 1.61 to 2.26)). Diabetes mellitus is a relatively common comorbidity encountered in THR. Diabetic patients have a higher rate of developing both surgical site and non-surgical site infections following THR. Cite this article: Bone Joint J 2013;95-B:1474–9


The Bone & Joint Journal
Vol. 96-B, Issue 8 | Pages 1041 - 1046
1 Aug 2014
Ollivier M Frey S Parratte S Flecher X Argenson JN

There is little in the literature on the level of participation in sports which patients undertake after total hip replacement (THR). Our aims in this study were to determine first, the level of sporting activity, second, the predictive factors for returning to sporting activity, and third, the correlation between participation in sports and satisfaction after THR. We retrospectively identified 815 patients who had undergone THR between 1995 and 2005. All were asked to complete a self-administered questionnaire regarding their sporting activity. A total of 571 patients (71%) met the inclusion criteria and completed the evaluation. At a mean follow-up of 9.8 years (. sd. 2.9), 366 patients (64%) returned to sporting activity as defined by a University of California at Los Angeles (UCLA) score of > 5. The main reasons that patients had for refraining from sports were fear of dislocation (65; 31.6%), avoiding wear (52; 25.4%), and the recommendation of the surgeon (34; 16.6%). There was a significant relationship between higher post-operative participation in sport in those patients with a higher pre-operative Harris hip score (HHS) (p = 0.0074), motivation to participate in sporting activities (p = 0.00022) and a shorter duration of symptoms (p = 0.0034). Finally, there was a correlation between age (p = 0.00013), UCLA score (p = 0.012) and pre-operative HHS (p = 0.00091) and satisfaction. In conclusion, we found that most patients participate in sporting activity after THR, regardless of the advice of their surgeon, and that there is a correlation between the level of participation and pre-operative function, motivation, duration of symptoms and post-operative satisfaction. Cite this article: Bone Joint J 2014;96-B:1041–6


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 11 - 16
1 Nov 2013
Sierra RJ Mabry TM Sems SA Berry DJ

Total hip replacement (THR) after acetabular fracture presents unique challenges to the orthopaedic surgeon. The majority of patients can be treated with a standard THR, resulting in a very reasonable outcome. Technical challenges however include infection, residual pelvic deformity, acetabular bone loss with ununited fractures, osteonecrosis of bone fragments, retained metalwork, heterotopic ossification, dealing with the sciatic nerve, and the difficulties of obtaining long-term acetabular component fixation. Indications for an acute THR include young patients with both femoral head and acetabular involvement with severe comminution that cannot be reconstructed, and the elderly, with severe bony comminution. The outcomes of THR for established post-traumatic arthritis include excellent pain relief and functional improvements. The use of modern implants and alternative bearing surfaces should improve outcomes further. Cite this article: Bone Joint J 2013;95-B, Supple A:11–16


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1557 - 1566
1 Nov 2012
Jameson SS Kyle J Baker PN Mason J Deehan DJ McMurtry IA Reed MR

United Kingdom National Institute for Health and Clinical Excellence guidelines recommend the use of total hip replacement (THR) for displaced intracapsular fractures of the femoral neck in cognitively intact patients, who were independently mobile prior to the injury. This study aimed to analyse the risk factors associated with revision of the implant and mortality following THR, and to quantify risk. National Joint Registry data recording a THR performed for acute fracture of the femoral neck between 2003 and 2010 were analysed. Cox proportional hazards models were used to investigate the extent to which risk of revision was related to specific covariates. Multivariable logistic regression was used to analyse factors affecting peri-operative mortality (< 90 days). A total of 4323 procedures were studied. There were 80 patients who had undergone revision surgery at the time of censoring (five-year revision rate 3.25%, 95% confidence interval 2.44 to 4.07) and 137 patients (3.2%) patients died within 90 days. After adjusting for patient and surgeon characteristics, an increased risk of revision was associated with the use of cementless prostheses compared with cemented (hazard ratio (HR) 1.33, p = 0.021). Revision was independent of bearing surface and head size. The risk of mortality within 90 days was significantly increased with higher American Society of Anesthesiologists (ASA) grade (grade 3: odds ratio (OR) 4.04, p < 0.001; grade 4/5: OR 20.26, p < 0.001; both compared with grades 1/2) and older age (≥ 75 years: OR 1.65, p = 0.025), but reduced over the study period (9% relative risk reduction per year). THR is a good option in patients aged < 75 years and with ASA 1/2. Cementation of the femoral component does not adversely affect peri-operative mortality but improves survival of the implant in the mid-term when compared with cementless femoral components. There are no benefits of using head sizes > 28 mm or bearings other than metal-on-polyethylene. More research is required to determine the benefits of THR over hemiarthroplasty in older patients and those with ASA grades > 2


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1458 - 1463
1 Nov 2013
Won S Lee Y Ha Y Suh Y Koo K

Pre-operative planning for total hip replacement (THR) is challenging in hips with severe acetabular deformities, including those with a hypoplastic acetabulum or severe defects and in the presence of arthrodesis or ankylosis. We evaluated whether a Rapid Prototype (RP) model, which is a life-sized reproduction based on three-dimensional CT scans, can determine the feasibility of THR and provide information about the size and position of the acetabular component in severe acetabular deformities. THR was planned using an RP model in 21 complex hips in five men (five hips) and 16 women (16 hips) with a mean age of 47.7 years (24 to 70) at operation. An acetabular component was implanted successfully and THR completed in all hips. The acetabular component used was within 2 mm of the predicted size in 17 hips (80.9%). All of the acetabular components and femoral stems had radiological evidence of bone ingrowth and stability at the final follow-up, without any detectable wear or peri-prosthetic osteolysis. The RP model allowed a simulated procedure pre-operatively and was helpful in determining the feasibility of THR pre-operatively, and to decide on implant type, size and position in complex THRs. Cite this article: Bone Joint J 2013;95-B:1458–63


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 339 - 342
1 Mar 2013
Milligan DJ O’Brien S Bennett D Hill JC Beverland DE

With greater numbers of younger patients undergoing total hip replacement (THR), the effect of patient age on the diameter of the femoral canal may become more relevant. This study aimed to investigate the relationship between the diameter of the diaphysis of the femoral canal with increasing age in a large number of patients who underwent THR. A total of 1685 patients scheduled for THR had their femoral dimensions recorded from calibrated radiographs. There were 736 males and 949 females with mean ages of 67.1 years (34 to 92) and 70.2 years (29 to 92), respectively. The mean diameter of the femoral canal was 13.3 mm (8.0 to 23.0) for males and 12.7 mm (6.0 to 26.0) for females. There was a poor correlation between age and the diameter of the canal in males (r = 0.071, p = 0.05) but a stronger correlation in females (r = 0.31, p < 0.001). The diameter of the femoral canal diameter of a female patient undergoing THR could be predicted to increase by 3.2 mm between the ages of 40 and 80 years, in contrast a male would be expected to experience only a 0.6 mm increase during the same period. This increase in the diameter of the canal with age might affect the long-term survival of the femoral component in female patients. Cite this article: Bone Joint J 2013;95-B:339–42


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 3 | Pages 400 - 403
1 May 1996
Voggenreiter G Assenmacher S Klaes W Schmit-Neuerburg K

We have used total hip replacement combined with cemented intramedullary nailing to treat a selected group of nine patients with pathological fractures of the proximal femur and impending fractures of the shaft due to metastases. One patient died from cardiopulmonary failure on the third postoperative day, but the others were able to walk within the first week after operation. Complications included one recurrent dislocation of the THR and one fracture of an osteolytic lesion of the femoral shaft during nail insertion. Both were managed successfully. The hybrid osteosynthesis which we describe is an alternative to the use of tumour or long-stem prostheses; it has the advantage of preserving bone stock and muscle attachments


Bone & Joint Research
Vol. 3, Issue 1 | Pages 7 - 13
1 Jan 2014
Keurentjes JC Van Tol FR Fiocco M So-Osman C Onstenk R Koopman-Van Gemert AWMM Pöll RG Nelissen RGHH

Objectives. To define Patient Acceptable Symptom State (PASS) thresholds for the Oxford hip score (OHS) and Oxford knee score (OKS) at mid-term follow-up. Methods. In a prospective multicentre cohort study, OHS and OKS were collected at a mean follow-up of three years (1.5 to 6.0), combined with a numeric rating scale (NRS) for satisfaction and an external validation question assessing the patient’s willingness to undergo surgery again. A total of 550 patients underwent total hip replacement (THR) and 367 underwent total knee replacement (TKR). Results. Receiver operating characteristic (ROC) curves identified a PASS threshold of 42 for the OHS after THR and 37 for the OKS after TKR. THR patients with an OHS ≥ 42 and TKR patients with an OKS ≥ 37 had a higher NRS for satisfaction and a greater likelihood of being willing to undergo surgery again. Conclusions. PASS thresholds appear larger at mid-term follow-up than at six months after surgery. With- out external validation, we would advise against using these PASS thresholds as absolute thresholds in defining whether or not a patient has attained an acceptable symptom state after THR or TKR. Cite this article: Bone Joint Res 2014;3:7–13


The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 239 - 243
1 Feb 2013
Liebs T Herzberg W Gluth J Rüther W Haasters J Russlies M Hassenpflug J

Although the Western Ontario and McMaster Universities (WOMAC) osteoarthritis index was originally developed for the assessment of non-operative treatment, it is commonly used to evaluate patients undergoing either total hip (THR) or total knee replacement (TKR). We assessed the importance of the 17 WOMAC function items from the perspective of 1198 patients who underwent either THR (n = 704) or TKR (n = 494) in order to develop joint-specific short forms. After these patients were administered the WOMAC pre-operatively and at three, six, 12 and 24 months’ follow-up, they were asked to nominate an item of the function scale that was most important to them. The items chosen were significantly different between patients undergoing THR and those undergoing TKR (p < 0.001), and there was a shift in the priorities after surgery in both groups. Setting a threshold for prioritised items of ≥ 5% across all follow-up, eight items were selected for THR and seven for TKR, of which six items were common to both. The items comprising specific WOMAC-THR and TKR function short forms were found to be equally responsive compared with the original WOMAC function form. . Cite this article: Bone Joint J 2013;95-B:239–43


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 974 - 981
1 Jul 2012
Scott CEH Bugler KE Clement ND MacDonald D Howie CR Biant LC

Patient expectations and their fulfilment are an important factor in determining patient-reported outcome and satisfaction of hip (THR) and knee replacement (TKR). The aim of this prospective cohort study was to examine the expectations of patients undergoing THR and TKR, and to identify differences in expectations, predictors of high expectations and the relationship between the fulfilment of expectations and patient-reported outcome measures. During the study period, patients who underwent 346 THRs and 323 TKRs completed an expectation questionnaire, Oxford score and Short-Form 12 (SF-12) score pre-operatively. At one year post-operatively, the Oxford score, SF-12, patient satisfaction and expectation fulfilment were assessed. Univariable and multivariable analysis were performed. Improvements in mobility and daytime pain were the most important expectations in both groups. Expectation level did not differ between THR and TKR. Poor Oxford score, younger age and male gender significantly predicted high pre-operative expectations (p < 0.001). The level of pre-operative expectation was not significantly associated with the fulfilment of expectations or outcome. THR better met the expectations identified as important by patients. TKR failed to meet expectations of kneeling, squatting and stair climbing. High fulfilment of expectation in both THR and TKR was significantly predicted by young age, greater improvements in Oxford score and high pre-operative mental health scores. The fulfilment of expectations was highly correlated with satisfaction


The Bone & Joint Journal
Vol. 96-B, Issue 3 | Pages 306 - 311
1 Mar 2014
Fujita K Kabata T Maeda T Kajino Y Iwai S Kuroda K Hasegawa K Tsuchiya H

It has recently been reported that the transverse acetabular ligament (TAL) is helpful in determining the position of the acetabular component in total hip replacement (THR). In this study we used a computer-assisted navigation system to determine whether the TAL is useful as a landmark in THR. The study was carried out in 121 consecutive patients undergoing primary THR (134 hips), including 67 dysplastic hips (50%). There were 26 men (29 hips) and 95 women (105 hips) with a mean age of 60.2 years (17 to 82) at the time of operation. After identification of the TAL, its anteversion was measured intra-operatively by aligning the inferomedial rim of the trial acetabular component with the TAL using computer-assisted navigation. The TAL was identified in 112 hips (83.6%). Intra-observer reproducibility in the measurement of anteversion of the TAL was high, but inter-observer reproducibility was moderate. . Each surgeon was able to align the trial component according to the target value of the angle of anteversion of the TAL, but it was clear that methods may differ among surgeons. Of the measurements of the angle of anteversion of the TAL, 5.4% (6 of 112 hips) were outliers from the safe zone. In summary, we found that the TAL is useful as a landmark when implanting the acetabular component within the safe zone in almost all hips, and to prevent it being implanted in retroversion in all hips, including dysplastic hips. However, as anteversion of the TAL may be excessive in a few hips, it is advisable to pay attention to individual variations, particularly in those with severe posterior pelvic tilt. Cite this article: Bone Joint J 2014;96-B:306–11


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1032 - 1035
1 Aug 2012
Griffiths EJ Stevenson D Porteous MJ

The debate whether to use cemented or uncemented components in primary total hip replacement (THR) has not yet been considered with reference to the cost implications to the National Health Service. We obtained the number of cemented and uncemented components implanted in 2009 from the National Joint Registry for England and Wales. The cost of each component was established. The initial financial saving if all were cemented was then calculated. Subsequently the five-year rates of revision for each type of component were reviewed and the predicted number of revisions at five years for the actual components used was compared with the predicted number of revisions for a cemented THR. This was then multiplied by the mean cost of revision surgery to provide an indication of the savings over the first five years if all primary THRs were cemented. The saving at primary THR was calculated to be £10 million with an additional saving during the first five years of between £5 million and £8.5 million. The use of cemented components in routine primary THR in the NHS as a whole can be justified on a financial level but we recognise individual patient factors must be considered when deciding which components to use


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 616 - 622
1 May 2013
Horstmann WG Swierstra MJ Ohanis D Castelein RM Kollen BJ Verheyen CCPM

Autologous retransfusion and no-drainage are both blood-saving measures in total hip replacement (THR). A new combined intra- and post-operative autotransfusion filter system has been developed especially for primary THR, and we conducted a randomised controlled blinded study comparing this with no-drainage. A total of 204 THR patients were randomised to autologous blood transfusion (ABT) (n = 102) or no-drainage (n = 102). In the ABT group, a mean of 488 ml (. sd. 252) of blood was retransfused. The mean lowest post-operative haemoglobin level during the hospital stay was higher in the autotransfusion group (10.6 g/dl (7.8 to 13.9) vs 10.2 g/dl (7.5 to 13.3); p = 0.01). The mean haemoglobin levels for the ABT and no-drainage groups were not significantly different on the first day (11.3 g/dl (7.8 to 13.9) vs 11.0 g/dl (8.1 to 13.4); p = 0.07), the second day (11.1 g/dl (8.2 to 13.8) vs 10.8 g/dl (7.5 to 13.3); p = 0.09) or the third day (10.8 g/dl (8.0 to 13.0) vs 10.6 g/dl (7.5 to 14.1); p = 0.15). The mean total peri-operative net blood loss was 1464 ml (. sd. 505) in the ABT group and 1654 ml (. sd. 553) in the no-drainage group (p = 0.01). Homologous blood transfusions were needed in four patients (3.9%) in the ABT group and nine (8.8%) in the no-drainage group (p = 0.15). No statistically significant difference in adverse events was found between the groups. The use of a new intra- and post-operative autologous blood transfusion filter system results in less total blood loss and a smaller maximum decrease in haemoglobin levels than no-drainage following primary THR. Cite this article: Bone Joint J 2013;95-B:616–22


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1036 - 1044
1 Aug 2012
Penny JO Brixen K Varmarken JE Ovesen O Overgaard S

It is accepted that resurfacing hip replacement preserves the bone mineral density (BMD) of the femur better than total hip replacement (THR). However, no studies have investigated any possible difference on the acetabular side. Between April 2007 and March 2009, 39 patients were randomised into two groups to receive either a resurfacing or a THR and were followed for two years. One patient’s resurfacing subsequently failed, leaving 19 patients in each group. Resurfaced replacements maintained proximal femoral BMD and, compared with THR, had an increased bone mineral density in Gruen zones 2, 3, 6, and particularly zone 7, with a gain of 7.5% (95% confidence interval (CI) 2.6 to 12.5) compared with a loss of 14.6% (95% CI 7.6 to 21.6). Resurfacing replacements maintained the BMD of the medial femoral neck and increased that in the lateral zones between 12.8% (95% CI 4.3 to 21.4) and 25.9% (95% CI 7.1 to 44.6). On the acetabular side, BMD was similar in every zone at each point in time. The mean BMD of all acetabular regions in the resurfaced group was reduced to 96.2% (95% CI 93.7 to 98.6) and for the total hip replacement group to 97.6% (95% CI 93.7 to 101.5) (p = 0.4863). A mean total loss of 3.7% (95% CI 1.0 to 6.5) and 4.9% (95% CI 0.8 to 9.0) of BMD was found above the acetabular component in W1 and 10.2% (95% CI 0.9 to 19.4) and 9.1% (95% CI 3.8 to 14.4) medial to the implant in W2 for resurfaced replacements and THRs respectively. Resurfacing resulted in a mean loss of BMD of 6.7% (95% CI 0.7 to 12.7) in W3 but the BMD inferior to the acetabular component was maintained in both groups. These results suggest that the ability of a resurfacing hip replacement to preserve BMD only applies to the femoral side


Bone & Joint 360
Vol. 2, Issue 1 | Pages 42 - 42
1 Feb 2013
Walker M


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 177 - 180
1 Feb 2014
Dossche L Noyez JF Ouedraogo W Kalmogho E

Total hip replacement (THR) still is a rare intervention in many African countries. In Burkina Faso it is not performed on a regular basis. A visiting programme for THR was started in a district hospital with no previous relevant experience. In this paper we present an analysis of the surgical technical problems and peri-operative complications of 152 THRs in 136 patients and three bipolar hemiarthroplasties in three patients undertaken in this new programme with limited orthopaedic equipment. There were 86 male and 53 female patients with a mean age of 49 years (21 to 78). We identified 77 intra-operative technical problems in 51 operations. There were 24 peri-operative complications in 21 patients, 17 of which were bony in nature. So far, ten revision THRs have been performed in nine patients. Regular analysis of the technical problems and complications was used to improve quality, and we identified patient selection adapted to the local circumstances as important to avoid complications. Our reflections on the problems encountered in initiating such a programme may be of help to other teams planning similar projects. Cite this article: Bone Joint J 2014;96-B:177–80


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 3 | Pages 507 - 507
1 May 1994
Hashemi-Nejad A Manktelow A Eastwood D


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 3 | Pages 506 - 507
1 May 1994
Gie G Ling R


Bone & Joint Research
Vol. 1, Issue 9 | Pages 225 - 233
1 Sep 2012
Paulsen A Odgaard A Overgaard S

Objectives. The Oxford hip score (OHS) is a 12-item questionnaire designed and developed to assess function and pain from the perspective of patients who are undergoing total hip replacement (THR). The OHS has been shown to be consistent, reliable, valid and sensitive to clinical change following THR. It has been translated into different languages, but no adequately translated, adapted and validated Danish language version exists. Methods. The OHS was translated and cross-culturally adapted into Danish from the original English version, using methods based on best-practice guidelines. The translation was tested for psychometric quality in patients drawn from a cohort from the Danish Hip Arthroplasty Register (DHR). Results. The Danish OHS had a response rate of 87.4%, no floor effect and a 19.9% ceiling effect (as expected in post-operative patients). Only 1.2% of patients had too many items missing to calculate a sum score. Construct validity was adequate and 80% of our predefined hypotheses regarding the correlation between scores on the Danish OHS and the other questionnaires were confirmed. The intraclass correlation (ICC) of the different items ranged from 0.80 to 0.95 and the average limits of agreement (LOA) ranged from -0.05 to 0.06. The Danish OHS had a high internal consistency with a Cronbach’s alpha of 0.99 and an average inter-item correlation of 0.88. Conclusions. This Danish version of the OHS is a valid and reliable patient-reported outcome measurement instrument (PROM) with similar qualities to the original English language version.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1330 - 1338
1 Oct 2012
Namba RS Inacio MCS Paxton EW

We examined patient and surgical factors associated with deep surgical site infection (SSI) following total hip replacement (THR) in a large integrated healthcare system. A retrospective review of a cohort of primary THRs performed between 2001 and 2009 was conducted. Patient characteristics, surgical details, surgeon and hospital volumes, and SSIs were identified using the Kaiser Permanente Total Joint Replacement Registry (TJRR). Proportional-hazard regression models were used to assess risk factors for SSI. The study cohort consisted of 30 491 THRs, of which 17 474 (57%) were performed on women. The mean age of the patients in the whole series was 65.5 years (13 to 97; . sd. 11.8) and the mean body mass index was 29.3 kg/m. 2. (15 to 67; . sd. 5.9). The incidence of SSI was 0.51% (155 of 30 491). Patient factors associated with SSI included female gender, obesity, and American Society of Anesthesiologists (ASA) score ≥ 3. Age, diagnosis, diabetes and race were not associated with SSI. The only surgical factor associated with SSI was a bilateral procedure. Surgeon and hospital volumes, use of antibiotic-laden cement, fixation method, laminar flow, body exhaust suits, surgical approach and fellowship training were not associated with risk of SSI. A comprehensive infection surveillance system, combined with a TJRR, identified patient and surgical factors associated with SSI. Obesity and chronic medical conditions should be addressed prior to THR. The finding of increased SSI risk with bilateral THR requires further investigation


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 6 | Pages 755 - 761
1 Jun 2012
Bosker BH Ettema HB Boomsma MF Kollen BJ Maas M Verheyen CCPM

Peri-articular soft-tissue masses or ‘pseudotumours’ can occur after large-diameter metal-on-metal (MoM) resurfacing of the hip and conventional total hip replacement (THR). Our aim was to assess the incidence of pseudotumour formation and to identify risk factors for their formation in a prospective cohort study. A total of 119 patients who underwent 120 MoM THRs with large-diameter femoral heads between January 2005 and November 2007 were included in the study. Outcome scores, serum metal ion levels, radiographs and CT scans were obtained. Patients with symptoms or an identified pseudotumour were offered MRI and an ultrasound-guided biopsy. There were 108 patients (109 hips) eligible for evaluation by CT scan at a mean follow-up of 3.6 years (2.5 to 4.5); 42 patients (39%) were diagnosed with a pseudotumour. The hips of 13 patients (12%) were revised to a polyethylene acetabular component with small-diameter metal head. Patients with elevated serum metal ion levels had a four times increased risk of developing a pseudotumour. This study shows a substantially higher incidence of pseudotumour formation and subsequent revisions in patients with MoM THRs than previously reported. Because most revision cases were identified only after an intensive screening protocol, we recommend close monitoring of patients with MoM THR


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 5 | Pages 796 - 801
1 Sep 1996
Kiss J Murray DW Turner-Smith AR Bithell JF Bulstrode CJ

We studied the migration of 58 cemented Hinek femoral components for total hip replacement,using roentgen stereophotogrammetric analysis over four years. The implants migrated faster during the first year than subsequently, and the pattern of migration in the second period was very different. During the first year they subsided, tilted into varus and internally rotated. After this there was slow distal migration with no change in orientation. None of the prostheses has yet failed.

The early migration is probably caused by resorption of bone damaged by surgical trauma or the heat generated by the polymerisation of bone cement. Later migration may be due to creep in the bone cement or the surrounding fibrous membrane.

The prosthesis which we studied allows the preservation of some of the femoral neck, and comparison with published migration studies of the Charnley stem suggests that this decreases rotation and may help to prevent loosening.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 2 | Pages 335 - 336
1 Mar 1995
McNally M Cooke E Mollan R


The Bone & Joint Journal
Vol. 95-B, Issue 9 | Pages 1178 - 1183
1 Sep 2013
Li H Mao Y Oni JK Dai K Zhu Z

In developmental dysplasia of the hip (DDH), a bone defect is often observed superior to the acetabulum after the reconstruction at the level of the true acetabulum during total hip replacement (THR). However, the essential amount of uncemented acetabular component coverage required for a satisfactory outcome remains controversial. The purpose of this study was to assess the stability and function of acetabular components with a lack of coverage > 30% (31% to 50%). A total of 760 DDH patients underwent THR with acetabular reconstruction at the level of the true floor. Lack of coverage above the acetabular component of > 30% occurred in 56 patients. Intra-operatively, autogenous morcellised bone grafts were used to fill the uncovered portion. Other than two screws inserted through the acetabular shell, no additional structural supports were used in these hips. In all, four patients were lost to follow-up. Therefore, 52 patients (52 hips, 41 women and 11 men) with a mean age of 60.1 years (42 to 78) were available for this study at a mean of 4.8 years (3 to 7). There were no instances of prosthesis revision or marked loosening during the follow-up. The Harris hip score improved from a mean of 40.7 points (. sd. 12.2) pre-operatively to 91.1 (. sd. 5.0) at the last follow-up. Radiological analysis with medical imaging software allowed us to calculate the extent of the uncoverage in terms of the uncovered arc of the implant as viewed on the anteroposterior pelvic radiograph. From this we propose that up to 17 mm of lateral undercoverage in the presence of a stable initial implantation in the presence of bone autografting, with an inclination angle of the acetabular component between 40° and 55°, is acceptable. This represents undercoverage of ≤ 50%. Cite this article: Bone Joint J 2013;95-B:1178–83


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 4 | Pages 616 - 617
1 Jul 1997
Volpin G Grimberg B Daniel M

We report an unusual complication of late dislocation of a total hip replacement. The femoral stem had completely migrated from the shaft. The insertion of a new long-stem prosthesis was successful.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 4 | Pages 668 - 668
1 Jul 1995
Esemenli B


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 2 | Pages 273 - 280
1 Mar 1999
Krismer M Biedermann R Stöckl B Fischer M Bauer R Haid C

We report the ten-year results for three designs of stem in 240 total hip replacements, for which subsidence had been measured on plain radiographs at regular intervals. Accurate migration patterns could be determined by the method of Einzel-Bild-Roentgen-Analyse-femoral component analysis (EBRA-FCA) for 158 hips (66%).

Of these, 108 stems (68%) remained stable throughout, and five (3%) started to migrate after a median of 54 months. Initial migration of at least 1 mm was seen in 45 stems (29%) during the first two years, but these then became stable. We revised 17 stems for aseptic loosening, and 12 for other reasons. Revision for aseptic loosening could be predicted by EBRA-FCA with a sensitivity of 69%, a specificity of 80%, and an accuracy of 79% by the use of a threshold of subsidence of 1.5 mm during the first two years. Similar observations over a five-year period allowed the long-term outcome to be predicted with an accuracy of 91%.

We discuss the importance of four different patterns of subsidence and confirm that the early measurement of migration by a reasonably accurate method can help to predict long-term outcome. Such methods should be used to evaluate new and modified designs of prosthesis.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 5 | Pages 705 - 714
1 Sep 1995
Walker P Mai S Cobb A Bentley G Hua J

We report the theoretical basis of a method to measure axial migration of femoral components of total hip replacements (THR). The use of the top of the greater trochanter and a lateral point on the collar of the stem, allowing for variations of up to 10 degrees rotation of the femur in any direction between successive radiographs, gave a maximum error of 0.37 mm. At a more realistic 5 degrees rotational variation, the error was only 0.13 mm. These data were confirmed in an experimental study using digitisation of points and special software. We also showed that the centre of the femoral head, the stem tip, and the lesser trochanter provided less accurate landmarks. In a second study we digitised a series of radiographs of 51 Charnley and 57 Stanmore THRs; the mean migration rates were found to be identical. We then studied 46 successful stems with a minimum follow-up of eight years and 46 stems which had failed by aseptic loosening at different times. At two years, the successful stems had migrated by a mean of 1.45 +/- 0.68 mm, but the failed cases had a mean migration of 4.32 +/- 2.58 mm (p < 0.0001). Of the successful cases 76% had migrated less than 2 mm, while in the failed group 84% had migrated more than 2 mm. For any particular case migration of more than 2.6 mm at two years had only a 5% chance of continuing success and would therefore merit special follow-up. Only 24% of the eventually successful stems showed migration at the stem-cement interface, but this had happened in every failed stem. We conclude that it would be possible to evaluate a new cemented design of femoral stem over a two-year period by the use of our method and to compare its performance against the reported known standard of the Charnley and Stanmore designs.


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1587 - 1594
1 Dec 2013
Ibrahim MS Twaij H Giebaly DE Nizam I Haddad FS

The outcome after total hip replacement has improved with the development of surgical techniques, better pain management and the introduction of enhanced recovery pathways. These pathways require a multidisciplinary team to manage pre-operative education, multimodal pain control and accelerated rehabilitation. The current economic climate and restricted budgets favour brief hospitalisation while minimising costs. This has put considerable pressure on hospitals to combine excellent results, early functional recovery and shorter admissions.

In this review we present an evidence-based summary of some common interventions and methods, including pre-operative patient education, pre-emptive analgesia, local infiltration analgesia, pre-operative nutrition, the use of pulsed electromagnetic fields, peri-operative rehabilitation, wound dressings, different surgical techniques, minimally invasive surgery and fast-track joint replacement units.

Cite this article: Bone Joint J 2013;95-B:1587–94.


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1617 - 1625
1 Dec 2013
Schmitz MWJL Timmer C Rijnen WHC Gardeniers JWM Schreurs BW

Despite the worldwide usage of the cemented Contemporary acetabular component (Stryker), no published data are available regarding its use in patients aged < 50 years. We undertook a mid- to long-term follow-up study, including all consecutive patients aged < 50 years who underwent a primary total hip replacement using the Contemporary acetabular component with the Exeter cemented stem between January 1999 and January 2006. There were 152 hips in 126 patients, 61 men and 65 women, mean age at surgery 37.6 years (16 to 49 yrs). One patient was lost to follow-up.

Mean clinical follow-up of all implants was 7.6 years (0.9 to 12.0). All clinical questionnaire scores, including Harris hip score, Oxford hip score and several visual analogue scales, were found to have improved. The eight year survivorship of all acetabular components for the endpoints revision for any reason or revision for aseptic loosening was 94.4% (95% confidence interval (CI) 89.2 to 97.2) and 96.4% (95% CI 91.6 to 98.5), respectively. Radiological follow-up was complete for 146 implants. The eight year survival for the endpoint radiological loosening was 93.1% (95% CI 86.2 to 96.6). Three surviving implants were considered radiologically loose but were asymptomatic. The presence of acetabular osteolysis (n = 17, 11.8%) and radiolucent lines (n = 20, 13.9%) in the 144 surviving cups indicates a need for continued observation in the second decade of follow-up in order to observe their influence on long-term survival.

The clinical and radiological data resulting in a ten-year survival rate > 90% in young patients support the use of the Contemporary acetabular component in this specific patient group.

Cite this article: Bone Joint J 2013;95-B:1617–25.


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 343 - 347
1 Mar 2013
Odak S Ivory J

Deficiency of the abductor mechanism is a well-recognised cause of pain and limping after total hip replacement (THR). This can be found incidentally at the time of surgery, or it may arise as a result of damage to the superior gluteal nerve intra-operatively, or after surgery owing to mechanical failure of the abductor muscle repair or its detachment from the greater trochanter. The incidence of abductor failure has been reported as high as 20% in some studies. The management of this condition remains a dilemma for the treating surgeon. We review the current state of knowledge concerning post-THR abductor deficiency, including the aetiology, diagnosis and management, and the outcomes of surgery for this condition.

Cite this article: Bone Joint J 2013;95-B:343–7.


Bone & Joint Research
Vol. 2, Issue 8 | Pages 140 - 148
1 Aug 2013
Gauthier L Dinh L Beaulé PE

Objectives

To quantify and compare peri-acetabular bone mineral density (BMD) between a monoblock acetabular component using a metal-on-metal (MoM) bearing and a modular titanium shell with a polyethylene (PE) insert. The secondary outcome was to measure patient-reported clinical function.

Methods

A total of 50 patients (25 per group) were randomised to MoM or metal-on-polyethlene (MoP). There were 27 women (11 MoM) and 23 men (14 MoM) with a mean age of 61.6 years (47.7 to 73.2). Measurements of peri-prosthetic acetabular and contralateral hip (covariate) BMD were performed at baseline and at one and two years’ follow-up. The Western Ontario and McMaster Universities osteoarthritis index (WOMAC), University of California, Los Angeles (UCLA) activity score, Harris hip score, and RAND-36 were also completed at these intervals.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 5 | Pages 603 - 608
1 May 2012
Vasukutty NL Middleton RG Matthews EC Young PS Uzoigwe CE Minhas THA

We present our experience with a double-mobility acetabular component in 155 consecutive revision total hip replacements in 149 patients undertaken between 2005 and 2009, with particular emphasis on the incidence of further dislocation. The mean age of the patients was 77 years (42 to 89) with 59 males and 90 females. In all, five patients died and seven were lost to follow-up. Indications for revision were aseptic loosening in 113 hips, recurrent instability in 29, peri-prosthetic fracture in 11 and sepsis in two. The mean follow-up was 42 months (18 to 68). Three hips (2%) in three patients dislocated within six weeks of surgery; one of these dislocated again after one year. All three were managed successfully with closed reduction. Two of the three dislocations occurred in patients who had undergone revision for recurrent dislocation. All three were found at revision to have abductor deficiency. There were no dislocations in those revised for either aseptic loosening or sepsis.

These results demonstrate a good mid-term outcome for this component. In the 29 patients revised for instability, only two had a further dislocation, both of which were managed by closed reduction.


The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 887 - 892
1 Jul 2013
Karachalios T Roidis N Lampropoulou-Adamidou K Hartofilakidis G

We report the results at a mean of 24.3 years (20 to 32) of 61 previously reported consecutive total hip replacements carried out on 44 patients with severe congenital hip disease, performed with reconstruction of the acetabulum with an impaction grafting technique known as cotyloplasty. The mean age of the patients at operation was 46.7 years (23 to 68) and all were women. The patients were followed post-operatively for a mean of 24.3 years (20 to 32), using the Merle d’Aubigné and Postel scoring system as modified by Charnley, and with serial radiographs. At the time of the latest follow-up, 28 acetabular components had been revised because of aseptic loosening at a mean of 15.9 years (6 to 26), and one at 40 days after surgery because of repeated dislocations. The overall survival rate for aseptic failure of the acetabular component at ten years was 93.1% (95% confidence interval (CI) 86.5 to 96.7) when 53 hips were at risk, and at 23 years was 56.1% (95% CI 49.4 to 62.8), when 22 hips remained at risk. These long-term results are considered satisfactory for the reconstruction of an acetabulum presenting with inadequate bone stock and circumferential segmental defects.

Cite this article: Bone Joint J 2013;95-B:887–92.


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 467 - 471
1 Apr 2013
Sandiford N Doctor C Rajaratnam SS Ahmed S East DJ Miles K Butler-Manuel A Shepperd JAN

We present the extended follow-up (≥ 20 years) of a series of fully hydroxyapatite-coated femoral components used in 72 primary total hip replacements (THRs). Earlier results of this cohort have been previously published. All procedures were performed between 1986 and 1991. The series involved 45 women and 15 men with 12 bilateral procedures. Their mean age at the time of surgery was 60 years (46 to 80) and the mean duration of follow-up was 22.5 years (20 to 25). At final follow-up, the mean Merle d’Aubigné and Postel hip scores were 5.5 (4.5 to 6), 3.8 (3.5 to 5) and 3.3 (3.0 to 5.0) for pain, mobility and function, respectively. Of the patients 92% were very satisfied at the time of final follow-up.

There were seven revisions: six of the acetabular component for aseptic loosening and one of both the stem and the acetabular component for loosening due to deep infection. The survival of this prosthesis at 22.5 years with revision for any reason as the endpoint was 91.7% (95% confidence interval (CI) 84 to 99). Survival with aseptic loosening of the stem as the endpoint was 100% (95% CI 90 to 100).

This prosthesis provides pain relief in the long term. Survival of this component is comparable to the best results for primary THR with any means of fixation.

Cite this article: Bone Joint J 2013;95-B:467–71.


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 333 - 338
1 Mar 2013
Jack CM Molloy DO Walter WL Zicat BA Walter WK

The practice of removing a well-fixed cementless femoral component is associated with high morbidity. Ceramic bearing couples are low wearing and their use minimises the risk of subsequent further revision due to the production of wear debris. A total of 165 revision hip replacements were performed, in which a polyethylene-lined acetabular component was revised to a new acetabular component with a ceramic liner, while retaining the well-fixed femoral component. A titanium sleeve was placed over the used femoral trunnion, to which a ceramic head was added. There were 100 alumina and 65 Delta bearing couples inserted.

The mean Harris hip score improved significantly from 71.3 (9.0 to 100.0) pre-operatively to 91.0 (41.0 to 100.0) at a mean follow up of 4.8 years (2.1 to 12.5) (p < 0.001). No patients reported squeaking of the hip.

There were two fractures of the ceramic head, both in alumina bearings. No liners were seen to fracture. No fractures were observed in components made of Delta ceramic. At 8.3 years post-operatively the survival with any cause of failure as the endpoint was 96.6% (95% confidence interval (CI) 85.7 to 99.3) for the acetabular component and 94.0% (95% CI 82.1 to 98.4) for the femoral component.

The technique of revising the acetabular component in the presence of a well-fixed femoral component with a ceramic head placed on a titanium sleeve over the used trunnion is a useful adjunct in revision hip practice. The use of Delta ceramic is recommended.

Cite this article: Bone Joint J 2013;95-B:333–8.


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 48 - 55
1 Nov 2014
Yasen AT Haddad FS

We are currently facing an epidemic of periprosthetic fractures around the hip. They may occur either during surgery or post-operatively. Although the acetabulum may be involved, the femur is most commonly affected. We are being presented with new, difficult fracture patterns around cemented and cementless implants, and we face the challenge of an elderly population who may have grossly deficient bone and may struggle to rehabilitate after such injuries. The correct surgical management of these fractures is challenging. This article will review the current choices of implants and techniques available to deal with periprosthetic fractures of the femur.

Cite this article: Bone Joint J 2014;96-B(11 Suppl A):48–55.


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 122 - 126
1 Jan 2014
Bloch BV Patel V Best AJ

Since the introduction of the National Institute for Health and Care Excellence (NICE) guidelines on thromboprophylaxis and the use of extended thromboprophylaxis with new oral agents, there have been reports of complications arising as a result of their use. We have looked at the incidence of wound complications after the introduction of dabigatran for thromboprophylaxis in our unit.

We investigated the rate of venous thromboembolism and wound leakage in 1728 patients undergoing primary joint replacement, both before and after the introduction of dabigatran, and following its subsequent withdrawal from our unit.

We found that the use of dabigatran led to a significant increase in post-operative wound leakage (20% with dabigatran, 5% with a multimodal regimen; p < 0.001), which also resulted in an increased duration of hospital stay. The rate of thromboembolism in patients receiving dabigatran was higher (1.3%) than in those receiving the multimodal thromboprophylaxis regimen, including low molecular weight heparin as an inpatient and the extended use of aspirin (0.3%, p = 0.047). We have ceased the use of dabigatran for thromboprophylaxis in these patients.

Cite this article: Bone Joint J 2014;96-B:122–6.


The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 160 - 165
1 Feb 2013
McDonnell SM Boyce G Baré J Young D Shimmin AJ

Noise generation has been reported with ceramic-on-ceramic articulations in total hip replacement (THR). This study evaluated 208 consecutive Delta Motion THRs at a mean follow-up of 21 months (12 to 35). There were 141 women and 67 men with a mean age of 59 years (22 to 84). Patients were reviewed clinically and radiologically, and the incidence of noise was determined using a newly described assessment method. Noise production was examined against range of movement, ligamentous laxity, patient-reported outcome scores, activity level and orientation of the acetabular component. There were 143 silent hips (69%), 22 (11%) with noises other than squeaking, 17 (8%) with unreproducible squeaking and 26 (13%) with reproducible squeaking. Hips with reproducible squeaking had a greater mean range of movement (p < 0.001) and mean ligament laxity (p = 0.004), smaller median head size (p = 0.01) and decreased mean acetabular component inclination (p = 0.02) and anteversion angle (p = 0.02) compared with the other groups. There was no relationship between squeaking and age (p = 0.13), height (p = 0.263), weight (p = 0.333), body mass index (p = 0.643), gender (p = 0.07) or patient outcome score (p = 0.422). There were no revisions during follow-up. Despite the surprisingly high incidence of squeaking, all patients remain satisfied with their hip replacement.

Cite this article: Bone Joint J 2013;95-B:160–5.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 113 - 121
1 Jan 2012
Poultsides LA Gonzalez Della Valle A Memtsoudis SG Ma Y Roberts T Sharrock N Salvati E

We performed a meta-analysis of modern total joint replacement (TJR) to determine the post-operative mortality and the cause of death using different thromboprophylactic regimens as follows: 1) no routine chemothromboprophylaxis (NRC); 2) Potent anticoagulation (PA) (unfractionated or low-molecular-weight heparin, ximelagatran, fondaparinux or rivaroxaban); 3) Potent anticoagulation combined (PAC) with regional anaesthesia and/or pneumatic compression devices (PCDs); 4) Warfarin (W); 5) Warfarin combined (WAC) with regional anaesthesia and/or PCD; and 6) Multimodal (MM) prophylaxis, including regional anaesthesia, PCDs and aspirin in low-risk patients. Cause of death was classified as autopsy proven, clinically certain or unknown. Deaths were grouped into cardiopulmonary excluding pulmonary embolism (PE), PE, bleeding-related, gastrointestinal, central nervous system, and others (miscellaneous). Meta-analysis based on fixed effects or random effects models was used for pooling incidence data.

In all, 70 studies were included (99 441 patients; 373 deaths). The mortality was lowest in the MM (0.2%) and WC (0.2%) groups. The most frequent cause of death was cardiopulmonary (47.9%), followed by PE (25.4%) and bleeding (8.9%). The proportion of deaths due to PE was not significantly affected by the thromboprophylaxis regimen (PA, 35.5%; PAC, 28%; MM, 23.2%; and NRC, 16.3%). Fatal bleeding was higher in groups relying on the use of anticoagulation (W, 33.8%; PA, 9.4%; PAC, 10.8%) but the differences were not statistically significant.

Our study demonstrated that the routine use of PA does not reduce the overall mortality or the proportion of deaths due to PE.


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 609 - 615
1 May 2013
Cadossi M Chiarello E Savarino L Tedesco G Baldini N Faldini C Giannini S

We undertook a randomised controlled trial to compare bipolar hemiarthroplasty (HA) with a novel total hip replacement (THR) comprising a polycarbonate–urethane (PCU) acetabular component coupled with a large-diameter metal femoral head for the treatment of displaced fractures of the femoral neck in elderly patients. Functional outcome, assessed with the Harris hip score (HHS) at three months and then annually after surgery, was the primary endpoint. Rates of revision and complication were secondary endpoints.

Based on a power analysis, 96 consecutive patients aged > 70 years were randomised to receive either HA (49) or a PCU-THR (47). The mean follow-up was 30.1 months (23 to 50) and 28.6 months (22 to 52) for the HA and the PCU group, respectively.

The HHS showed no statistically significant difference between the groups at every follow-up. Higher pain was recorded in the PCU group at one and two years’ follow-up (p = 0.006 and p = 0.019, respectively). In the HA group no revision was performed. In the PCU-THR group six patients underwent revision and one patient is currently awaiting re-operation. The three-year survival rate of the PCU-THR group was 0.841 (95% confidence interval 0.680 to 0.926).

Based on our findings we do not recommend the use of the PCU acetabular component as part of the treatment of patients with fractures of the femoral neck.

Cite this article: Bone Joint J 2013;95-B:609–15.


Bone & Joint Research
Vol. 1, Issue 8 | Pages 180 - 191
1 Aug 2012
Stilling M Kold S de Raedt S Andersen NT Rahbek O Søballe K

Objectives

The accuracy and precision of two new methods of model-based radiostereometric analysis (RSA) were hypothesised to be superior to a plain radiograph method in the assessment of polyethylene (PE) wear.

Methods

A phantom device was constructed to simulate three-dimensional (3D) PE wear. Images were obtained consecutively for each simulated wear position for each modality. Three commercially available packages were evaluated: model-based RSA using laser-scanned cup models (MB-RSA), model-based RSA using computer-generated elementary geometrical shape models (EGS-RSA), and PolyWare. Precision (95% repeatability limits) and accuracy (Root Mean Square Errors) for two-dimensional (2D) and 3D wear measurements were assessed.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 167 - 172
1 Feb 2012
Buttaro MA Costantini J Comba F Piccaluga F

We determined the midterm survival, incidence of peri-prosthetic fracture and the enhancement of the width of the femur when combining struts and impacted bone allografts in 24 patients (25 hips) with severe femoral bone loss who underwent revision hip surgery. The pre-operative diagnosis was aseptic loosening in 16 hips, second-stage reconstruction in seven, peri-prosthetic fracture in one and stem fracture in one hip. A total of 14 hips presented with an Endoklinik grade 4 defect and 11 hips a grade 3 defect. The mean pre-operative Merle D’Aubigné and Postel score was 5.5 points (1 to 8).

The survivorship was 96% (95% confidence interval 72 to 98) at a mean of 54.5 months (36 to 109). The mean functional score was 17.3 points (16 to 18). One patient in which the strut did not completely bypass the femoral defect was further revised using a long cemented stem due to peri-prosthetic fracture at six months post-operatively. The mean subsidence of the stem was 1.6 mm (1 to 3). There was no evidence of osteolysis, resorption or radiolucencies during follow-up in any hip. Femoral width was enhanced by a mean of 41% (19% to 82%). A total of 24 hips had partial or complete bridging of the strut allografts.

This combined biological method was associated with a favourable survivorship, a low incidence of peri-prosthetic fracture and enhancement of the width of the femur in revision total hip replacement in patients with severe proximal femoral bone loss.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 32 - 36
1 Jan 2012
Nho J Lee Y Kim HJ Ha Y Suh Y Koo K

A variety of radiological methods of measuring version of the acetabular component after total hip replacement (THR) have been described. The aim of this study was to evaluate the reliability and validity of six methods (those of Lewinnek; Widmer; Hassan et al; Ackland, Bourne and Uhthoff; Liaw et al; and Woo and Morrey) that are currently in use. In 36 consecutive patients who underwent THR, version of the acetabular component was measured by three independent examiners on plain radiographs using these six methods and compared with measurements using CT scans. The intra- and interobserver reliabilities of each measurement were estimated. All measurements on both radiographs and CT scans had excellent intra- and interobserver reliability and the results from each of the six methods correlated well with the CT measurements. However, measurements made using the methods of Widmer and of Ackland, Bourne and Uhthoff were significantly different from the CT measurements (both p < 0.001), whereas measurements made using the remaining four methods were similar to the CT measurements. With regard to reliability and convergent validity, we recommend the use of the methods described by Lewinnek, Hassan et al, Liaw et al and Woo and Morrey for measurement of version of the acetabular component.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 144 - 147
1 Nov 2013
Jones RE Russell RD Huo MH

Satisfactory primary wound healing following total joint replacement is essential. Wound healing problems can have devastating consequences for patients. Assessment of their healing capacity is useful in predicting complications. Local factors that influence wound healing include multiple previous incisions, extensive scarring, lymphoedema, and poor vascular perfusion. Systemic factors include diabetes mellitus, inflammatory arthropathy, renal or liver disease, immune compromise, corticosteroid therapy, smoking, and poor nutrition. Modifications in the surgical technique are necessary in selected cases to minimise potential wound complications. Prompt and systematic intervention is necessary to address any wound healing problems to reduce the risks of infection and other potential complications.

Cite this article: Bone Joint J 2013;95-B, Supple A:144–7.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1482 - 1486
1 Nov 2012
Brogan K Charity J Sheeraz A Whitehouse SL Timperley AJ Howell JR Hubble MJW

The technique of femoral cement-in-cement revision is well established, but there are no previous series reporting its use on the acetabular side at the time of revision total hip replacement. We describe the technique and report the outcome of 60 consecutive acetabular cement-in-cement revisions in 59 patients at a mean follow-up of 8.5 years (5 to 12). All had a radiologically and clinically well-fixed acetabular cement mantle at the time of revision. During the follow-up 29 patients died, but no hips were lost to follow-up. The two most common indications for acetabular revision were recurrent dislocation (46, 77%) and to complement femoral revision (12, 20%).

Of the 60 hips, there were two cases of aseptic loosening of the acetabular component (3.3%) requiring re-revision. No other hip was clinically or radiologically loose (96.7%) at the latest follow-up. One hip was re-revised for infection, four for recurrent dislocation and one for disarticulation of a constrained component. At five years the Kaplan-Meier survival rate was 100% for aseptic loosening and 92.2% (95% CI 84.8 to 99.6), with revision for any cause as the endpoint.

These results support the use of cement-in-cement revision on the acetabular side in appropriate cases. Theoretical advantages include preservation of bone stock, reduced operating time, reduced risk of complications and durable fixation.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 889 - 894
1 Jul 2012
Burston BJ Barnett AJ Amirfeyz R Yates PJ Bannister GC

We prospectively followed 191 consecutive collarless polished tapered (CPT) femoral stems, implanted in 175 patients who had a mean age at operation of 64.5 years (21 to 85). At a mean follow-up of 15.9 years (14 to 17.5), 86 patients (95 hips) were still alive. The fate of all original stems is known. The 16-year survivorship with re-operation for any reason was 80.7% (95% confidence interval 72 to 89.4). There was no loss to follow-up, with clinical data available on all 95 hips and radiological assessment performed on 90 hips (95%). At latest follow-up, the mean Harris hip score was 78 (28 to 100) and the mean Oxford hip score was 36 (15 to 48). Stems subsided within the cement mantle, with a mean subsidence of 2.1 mm (0.4 to 19.2). Among the original cohort, only one stem (0.5%) has been revised due to aseptic loosening. In total seven stems were revised for any cause, of which four revisions were required for infection following revision of the acetabular component. A total of 21 patients (11%) required some sort of revision procedure; all except three of these resulted from failure of the acetabular component. Cemented acetabular components had a significantly lower revision burden (three hips, 2.7%) than Harris Galante uncemented components (17 hips, 21.8%) (p < 0.001).

The CPT stem continues to provide excellent radiological and clinical outcomes at 15 years following implantation. Its results are consistent with other polished tapered stem designs.