Advertisement for orthosearch.org.uk
Results 1 - 50 of 199
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 42-B, Issue 2 | Pages 205 - 212
1 May 1960
Clawson DK Seddon HJ

1. The results of repair of the sciatic nerve and of its main divisions have been analysed in a series of 118 cases, the patients having been under observation for three to eighteen years (average 11·7 years). 2. A result was satisfactory if there was some return of sensibility throughout the autonomous zone (the area of skin supplied exclusively by the damaged nerve) and if the more important muscles of the leg were capable of contraction against gravity and resistance. 3. When the whole of the sciatic nerve is damaged it is necessary to present the results separately for the lateral and medial popliteal divisions. 4. Of forty-seven cases of repair of the medial popliteal nerve 79 per cent showed useful motor and 62 per cent useful sensory recovery. In three out of four cases the correspondence between the degree of motor and of sensory recovery was fairly close. 5. Of seventy-two cases of repair of the lateral popliteal nerve 36 per cent showed useful motor and 74 per cent useful sensory recovery. The latter figure must be regarded with some reserve because sensory "recovery" in the lateral popliteal zone may be due to the ingrowth of nerve fibres from contiguous normally innervated skin. Thus it is not possible to correlate motor and sensory recovery. 6. In eighteen cases of repair of the posterior tibial nerve, there was useful sensory recovery in the sole in twelve. But although there was evidence of recovery in the plantar muscles in eleven cases it was functionally valueless. 7. In repair of the medial popliteal nerve the result was better if suture had been carried out early. In repair of the lateral popliteal nerve there was no evidence that delay was harmful; but the proportion of good results was so low (as judged by motor function alone, sensory recovery being often extraneous) that this exception to a general rule cannot be taken very seriously. 8. Gaps of up to twelve centimetres–estimated after resection of the damaged nerve ends–could be closed without difficulty by the usual technique, and the extent of the gap up to that limit had no influence on the prognosis. The closure of larger gaps, when the knee must be flexed beyond a right angle, is not compatible with good recovery because the post-operative stretching of the nerve causes serious intraneural damage. 9. Nerve grafting has given poor results in repair of the sciatic nerve


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 242 - 243
1 Feb 2007
Uppal HS Gwilym SE Crawfurd EJP Birch R

We report a case of iatrogenic sciatic nerve injury caused by pre-operative intraneural injection of local anaesthetic at total hip replacement. To our knowledge, this is unreported in the orthopaedic literature. We consider sacral nerve blockade in patients undergoing total hip replacement to be undesirable and present guidelines for the management of peri-operative sciatic nerve injury


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 3 | Pages 363 - 365
1 Apr 2003
Fleming P Lenehan B O’Rourke S McHugh P Kaar K McCabe JP

Injuries to the sciatic nerve are an occasional complication of surgery to the hip and acetabulum, and traction is frequently the causative mechanism. In vitro and animal experiments have shown that increased tensile strain on peripheral nerves, when applied for prolonged periods, impairs nerve function. We have used video-extensometry to measure strain on the human sciatic nerve during total hip replacement (THR). Ten consecutive patients with a mean age of 72 years undergoing primary THR by the posterior approach were recruited, and strains in the sciatic nerve were measured in different combinations of flexion and extension of the hip and knee, before dislocation of the hip. Significant increases (p = 0.02) in strain in the sciatic nerve were observed in flexion of the hip and extension of the knee. The mean increase was 26% (19% to 30%). In animal studies increases of this magnitude have been shown to impair electrophysiological function in peripheral nerves. Our results suggest that excessive flexion of the hip and extension of the knee should be avoided during THR


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 7 | Pages 1059 - 1061
1 Sep 2004
Katz K Attias J Weigl D Cizger A Bar-on E

Traction injury to the sciatic nerve can occur during hamstring lengthening. The aim of this study was to monitor the influence of hamstring lengthening on conduction in the sciatic nerve using evoked electromyography (EMG). Ten children with spastic cerebral palsy underwent bilateral distal hamstring lengthening. Before lengthening, the evoked potential was recorded with the patient prone. During lengthening, it was recorded with the knee flexed to 90°, 60° and 30°, and at the end of lengthening with the hip and knee extended. In all patients, the amplitude of the evoked EMG gradually decreased with increasing lengthening. The mean decrease with the knee flexed to 60° was 34% (10 to 77), and to 30°, 86% (52 to 98) compared with the pre-lengthening amplitude. On hip extension at the end of the lengthening procedure, the EMG returned to the pre-lengthening level. Monitoring of the evoked EMG potential of the sciatic nerve during and after hamstring lengthening, may be helpful in preventing traction injury


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 274 - 276
1 Feb 2011
Chan JHH Ballal MS Dheerendra S Sanchez-Ballester J Pydisetty RV

Injury to the sciatic nerve following closed manipulation of a dislocated total hip replacement is rare. We present such a case in an elderly patient with partial recovery following exploration and release of the nerve


The Journal of Bone & Joint Surgery British Volume
Vol. 42-B, Issue 2 | Pages 213 - 225
1 May 1960
Clawson DK Seddon HJ

1. We have described what happens to patients a number of years after injury of the sciatic nerve or of its divisions; there were 329 who had been under observation for periods ranging from three to eighteen years. The neurological recovery was recorded in every case and, more important, the behaviour of the limb as appreciated by the patient. 2. Although it was generally true that good neurological recovery and good function went together there were remarkable discrepancies. Isolated paralysis of the medial popliteal or of the lateral popliteal nerve was often compatible with good function, though patients with lateral popliteal paralysis usually needed toe-raising apparatus. Even total sciatic paralysis sometimes gave little trouble. 3. Of the various types of injury, clean wounds and traction lesions led to rather better than average return of function. 4. Some degree of pain was present in about half the cases, and over-response–exaggerated and painful response to an ordinary stimulus–was present in one-third of the cases. 5. Repair of the posterior tibial nerve was rarely worth while; no less than eight out of twelve patients with this type of injury exhibited over-response. 6. One-third of the patients showed vasomotor and trophic disorders: coldness of the affected limb, erythema, thinness or pigmentation of the skin, changes in the nails or oedema. 7. Pressure sores were the most serious consequence of sciatic nerve injury and at some time or other were present in 14 per cent of our patients. The cause was deformity rather than insensibility of the sole. 8. Of the various palliative operations Lambrinudi's tarsal arthrodesis gave such disappointing results that we doubt whether the operation is worth doing. Tenodesis, revived as a time-saving expedient during the war, was a failure. For lateral popliteal paralysis anterior transplantation of tibialis posterior is excellent. 9. Amputation was done in only ten cases. When it was performed for fixed deformity with secondary ulceration the result was satisfactory. When it was done because of pain there was no relief. Amputation is, therefore, avoidable provided that vigorous steps are taken to prevent or correct deformity; it should not be done for the relief of pain


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 5 | Pages 731 - 733
1 Sep 1992
Birch R Wilkinson M Vijayan K Gschmeissner S

We present the case of a 63-year-old woman who sustained an acrylic cement burn of the sciatic nerve at hip replacement. She was treated by resection of the damaged segment and grafting. Electron microscopy showed that the nerve was nearly normal 1 cm from the cement margin indicating that this is a safe level for resection


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 8 | Pages 1178 - 1180
1 Nov 2003
Crawford JR Van Rensburg L Marx C

Pain in the distribution of the sciatic nerve is common in the elderly. In the presence of a long-standing joint replacement, consideration should be given as to whether compression might be due to an extraspinal cause. We present three women, in whom a mass of wear debris from a previous total hip replacement caused compression of the sciatic nerve posterior to the hip. The symptoms were relieved immediately following operation


The Journal of Bone & Joint Surgery British Volume
Vol. 35-B, Issue 2 | Pages 192 - 195
1 May 1953
Cram RH

Experiments have shown that the tension of the sciatic nerve roots is increased when the posterior tibial nerve is pressed upon in the popliteal space. A refinement of the straight leg raising test, based on this observation, is described


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 2 | Pages 253 - 257
1 Feb 2009
Manidakis N Kanakaris NK Nikolaou VS Giannoudis PV

We describe a patient in whom an initially intact sciatic nerve became rapidly encased in heterotopic bone formed in the abductor compartment after reconstruction of the posterior wall of the acetabulum following fracture. Prompt excision and neural release followed by irradiation and administration of indometacin resulted in a full neurological recovery and no recurrence 27 months later


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 5 | Pages 729 - 730
1 Sep 1992
Oleksak M Edge A

Severe leg pain in a patient after total hip replacement was found to be caused by compression of the sciatic nerve by methylmethacrylate cement which had leaked from the acetabulum during fixation of the acetabular cup. The pain persisted for six years but was immediately relieved by removal of the cement mass


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 5 | Pages 829 - 833
1 Nov 1986
Glasby M Gschmeissner S Hitchcock R Huang C

An orientated substratum has been implicated in the development and regeneration of axons and synapses. We prepared a basement membrane matrix from autogenous striated muscle, used it to repair the sciatic nerve in rats, then investigated the results by histology and electrophysiology. When treated grafts were coaxially aligned with the nerve fascicles functional recovery appeared within 30 days, with good growth of axons into the distal nerve. Grafts with myotubes at right angles to the nerve fascicles supported nerve regeneration but at a slower rate. Grafts of coaxially aligned but untreated muscle allowed axon penetration only through naturally degenerated muscle fibres, with minimal axon penetration of the distal nerve. It is concluded that in the rat a treated graft with correctly orientated empty myotubes can facilitate and guide the regeneration of peripheral nerve after injury and so lead to recolonisation of the distal stump with functional recovery


The Journal of Bone & Joint Surgery British Volume
Vol. 46-B, Issue 4 | Pages 748 - 763
1 Nov 1964
Adams JC

1. The risk of injury to the sciatic nerve during closed ischio-femoral arthrodesis by nail and graft has been assessed on the basis of clinical evidence and of anatomical studies in the living and in cadavers. 2. The margin of safety for the nerve is nearly always small. 3. The risk of injury to the nerve is prohibitive when there is marked deformity or hypoplasia of the pelvis. The risk is also increased when the buttock is compressed against the table and, because of the technical difficulties that are entailed, when the hip is in marked flexion. The risk is probably greater in children than in adults. 4. In properly selected cases in which none of these adverse factors is present it is submitted that the risk of nerve injury can be eliminated by proper attention to surgical technique and by the observance of certain definite precautions. 5. When there is doubt in the surgeon's mind about his ability to complete the operation without injuring the nerve the closed technique should be abandoned in favour of the open posterior approach


Bone & Joint Open
Vol. 3, Issue 5 | Pages 415 - 422
17 May 2022
Hillier-Smith R Paton B

Aims. Avulsion of the proximal hamstring tendon origin can result in significant functional impairment, with surgical re-attachment of the tendons becoming an increasingly recognized treatment. The aim of this study was to assess the outcomes of surgical management of proximal hamstring tendon avulsions, and to compare the results between acute and chronic repairs, as well as between partial and complete injuries. Methods. PubMed, CINAHL, SPORTdiscuss, Cochrane Library, EMBASE, and Web of Science were searched. Studies were screened and quality assessed. Results. In all, 35 studies (1,530 surgically-repaired hamstrings) were included. Mean age at time of repair was 44.7 years (12 to 78). A total of 846 tears were acute, and 684 were chronic, with 520 tears being defined as partial, and 916 as complete. Overall, 92.6% of patients were satisfied with the outcome of their surgery. Mean Lower Extremity Functional Score was 74.7, and was significantly higher in the partial injury group. Mean postoperative hamstring strength was 87.0% of the uninjured limb, and was higher in the partial group. The return to sport (RTS) rate was 84.5%, averaging at a return of 6.5 months. RTS was quicker in the acute group. Re-rupture rate was 1.2% overall, and was lower in the acute group. Sciatic nerve dysfunction rate was 3.5% overall, and lower in the acute group (p < 0.05 in all cases). Conclusion. Surgical treatment results in high satisfaction rates, with good functional outcomes, restoration of muscle strength, and RTS. Partial injuries could expect a higher functional outcome and muscle strength return. Acute repairs result in a quicker RTS with a reduced rate of re-rupture and sciatic nerve dysfunction. Cite this article: Bone Jt Open 2022;3(5):415–422


The Journal of Bone & Joint Surgery British Volume
Vol. 42-B, Issue 2 | Pages 175 - 176
1 May 1960
Barnes R


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1056 - 1062
1 Aug 2015
Kanawati AJ Narulla RS Lorentzos P Facchetti G Smith A Stewart F

The aim of this cadaver study was to identify the change in position of the sciatic nerve during arthroplasty using the posterior surgical approach to the hip. We investigated the position of the nerve during this procedure by dissecting 11 formalin-treated cadavers (22 hips: 12 male, ten female). The distance between the sciatic nerve and the femoral neck was measured before and after dislocation of the hip, and in positions used during the preparation of the femur. The nerve moves closer to the femoral neck when the hip is flexed to > 30° and internally rotated to 90° (90° IR). The mean distance between the nerve and femoral neck was 43.1 mm (standard deviation (. sd. ) 8.7) with the hip at 0° of flexion and 90° IR; this significantly decreased to a mean of 36.1 mm (. sd. 9.5), 28.8 mm (. sd. 9.8) and 19.1 mm (. sd. 9.7) at 30°, 60° and 90° of hip flexion respectively (p < 0.001). In two hips the nerve was in contact with the femoral neck when the hip was flexed to 90°. . This study demonstrates that the sciatic nerve becomes closer to the operative field during hip arthroplasty using the posterior approach with progressive flexion of the hip. Cite this article: Bone Joint J 2015;97-B:1056–62


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 5 | Pages 706 - 706
1 Nov 1986
Merrild U Sogaard I


The Journal of Bone & Joint Surgery British Volume
Vol. 54-B, Issue 1 | Pages 152 - 153
1 Feb 1972
Leonard MA

1. A case of complete sciatic palsy complicating anticoagulant therapy is presented.

2. A brief review of the possible pathogenesis is made and the importance of early recognition and treatment of the syndrome is emphasised.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 179 - 184
1 Feb 2012
Sutter M Hersche O Leunig M Guggi T Dvorak J Eggspuehler A

Peripheral nerve injury is an uncommon but serious complication of hip surgery that can adversely affect the outcome. Several studies have described the use of electromyography and intra-operative sensory evoked potentials for early warning of nerve injury. We assessed the results of multimodal intra-operative monitoring during complex hip surgery. We retrospectively analysed data collected between 2001 and 2010 from 69 patients who underwent complex hip surgery by a single surgeon using multimodal intra-operative monitoring from a total pool of 7894 patients who underwent hip surgery during this period. In 24 (35%) procedures the surgeon was alerted to a possible lesion to the sciatic and/or femoral nerve. Alerts were observed most frequently during peri-acetabular osteotomy. The surgeon adapted his approach based on interpretation of the neurophysiological changes. From 69 monitored surgical procedures, there was only one true positive case of post-operative nerve injury. There were no false positives or false negatives, and the remaining 68 cases were all true negative. The sensitivity for predicting post-operative nerve injury was 100% and the specificity 100%. We conclude that it is possible and appropriate to use this method during complex hip surgery and it is effective for alerting the surgeon to the possibility of nerve injury.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 11 | Pages 1465 - 1467
1 Nov 2005
Butt AJ McCarthy T Kelly IP Glynn T McCoy G

Sciatic nerve palsy is a recognised complication of primary total hip replacement. In our unit this complication was rare with an incidence of < 0.2% in the past ten years. We describe six cases of sciatic nerve palsy occurring in 355 consecutive primary total hip replacements (incidence 1.69%). Each of these palsies was caused by post-operative haematoma in the region of the sciatic nerve. Cases, which were recognised early and surgically-evacuated promptly, showed earlier and more complete recovery. Those patients for whom the diagnosis was delayed, and who were therefore managed expectantly, showed little or no recovery. Unexpected pain and significant swelling in the buttock, as well as signs of sciatic nerve irritation, suggest the presence of haematoma in the region of the sciatic nerve. It is, therefore, of prime importance to be vigilant for the features of a sciatic nerve palsy in the early post-operative period as, when recognised and treated early, the injury to the sciatic nerve may be reversed


Bone & Joint Open
Vol. 4, Issue 2 | Pages 53 - 61
1 Feb 2023
Faraj S de Windt TS van Hooff ML van Hellemondt GG Spruit M

Aims. The aim of this study was to assess the clinical and radiological results of patients who were revised using a custom-made triflange acetabular component (CTAC) for component loosening and pelvic discontinuity (PD) after previous total hip arthroplasty (THA). Methods. Data were extracted from a single centre prospective database of patients with PD who were treated with a CTAC. Patients were included if they had a follow-up of two years. The Hip Disability and Osteoarthritis Outcome Score (HOOS), modified Oxford Hip Score (mOHS), EurQol EuroQoL five-dimension three-level (EQ-5D-3L) utility, and Numeric Rating Scale (NRS), including visual analogue score (VAS) for pain, were gathered at baseline, and at one- and two-year follow-up. Reasons for revision, and radiological and clinical complications were registered. Trends over time are described and tested for significance and clinical relevance. Results. A total of 18 females with 22 CTACs who had a mean age of 73.5 years (SD 7.7) were included. A significant improvement was found in HOOS (p < 0.0001), mOHS (p < 0.0001), EQ-5D-3L utility (p = 0.003), EQ-5D-3L NRS (p = 0.013), VAS pain rest (p = 0.008), and VAS pain activity (p < 0.0001) between baseline and final follow-up. Minimal clinically important improvement in mOHS and the HOOS Physical Function Short Form (HOOS-PS) was observed in 16 patients (73%) and 14 patients (64%), respectively. Definite healing of the PD was observed in 19 hips (86%). Complications included six cases with broken screws (27%), four cases (18%) with bony fractures, and one case (4.5%) with sciatic nerve paresthesia. One patient with concurrent bilateral PD had revision surgery due to recurrent dislocations. No revision surgery was performed for screw failure or implant breakage. Conclusion. CTAC in patients with THA acetabular loosening and PD can result in stable constructs and significant improvement in functioning and health-related quality of life at two years' follow-up. Further follow-up is necessary to determine the mid- to long-term outcome. Cite this article: Bone Jt Open 2023;4(2):53–61


The Bone & Joint Journal
Vol. 102-B, Issue 5 | Pages 556 - 567
1 May 2020
Park JW Lee Y Lee YJ Shin S Kang Y Koo K

Deep gluteal syndrome is an increasingly recognized disease entity, caused by compression of the sciatic or pudendal nerve due to non-discogenic pelvic lesions. It includes the piriformis syndrome, the gemelli-obturator internus syndrome, the ischiofemoral impingement syndrome, and the proximal hamstring syndrome. The concept of the deep gluteal syndrome extends our understanding of posterior hip pain due to nerve entrapment beyond the traditional model of the piriformis syndrome. Nevertheless, there has been terminological confusion and the deep gluteal syndrome has often been undiagnosed or mistaken for other conditions. Careful history-taking, a physical examination including provocation tests, an electrodiagnostic study, and imaging are necessary for an accurate diagnosis. After excluding spinal lesions, MRI scans of the pelvis are helpful in diagnosing deep gluteal syndrome and identifying pathological conditions entrapping the nerves. It can be conservatively treated with multidisciplinary treatment including rest, the avoidance of provoking activities, medication, injections, and physiotherapy. Endoscopic or open surgical decompression is recommended in patients with persistent or recurrent symptoms after conservative treatment or in those who may have masses compressing the sciatic nerve. Many physicians remain unfamiliar with this syndrome and there is a lack of relevant literature. This comprehensive review aims to provide the latest information about the epidemiology, aetiology, pathology, clinical features, diagnosis, and treatment. Cite this article: Bone Joint J 2020;102-B(5):556–567


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 129 - 134
1 Jul 2021
Ayekoloye CI Abu Qa'oud M Radi M Leon SA Kuzyk P Safir O Gross AE

Aims. Improvements in functional results and long-term survival are variable following conversion of hip fusion to total hip arthroplasty (THA) and complications are high. The aim of the study was to analyze the clinical and functional results in patients who underwent conversion of hip fusion to THA using a consistent technique and uncemented implants. Methods. A total of 39 hip fusion conversions to THA were undertaken in 38 patients by a single surgeon employing a consistent surgical technique and uncemented implants. Parameters assessed included Harris Hip Score (HHS) for function, range of motion (ROM), leg length discrepancy (LLD), satisfaction, and use of walking aid. Radiographs were reviewed for loosening, subsidence, and heterotopic ossification (HO). Postoperative complications and implant survival were assessed. Results. At mean 12.2 years (2 to 24) follow-up, HHS improved from mean 34.2 (20.8 to 60.5) to 75 (53.6 to 94.0; p < 0.001). Mean postoperative ROM was flexion 77° (50° to 95°), abduction 30° (10° to 40°), adduction 20° (5° to 25°), internal rotation 18° (2° to 30°), and external rotation 17° (5° to 30°). LLD improved from mean -3.36 cm (0 to 8) to postoperative mean -1.14 cm (0 to 4; p < 0.001). Postoperatively, 26 patients (68.4%) required the use of a walking aid. Complications included one (2.5%) dislocation, two (5.1%) partial sciatic nerve injuries, one (2.5%) deep periprosthetic joint infection, two instances of (5.1%) acetabular component aseptic loosening, two (5.1%) periprosthetic fractures, and ten instances of HO (40%), of which three (7.7%) were functionally limiting and required excision. Kaplan-Meier Survival was 97.1% (95% confidence interval (CI) 91.4% to 100%) at ten years and 88.2% (95% CI 70.96 to 100) at 15 years with implant revision for aseptic loosening as endpoint and 81.7% (95% CI 70.9% to 98.0%) at ten years and 74.2% (95% CI 55.6 to 92.8) at 15 years follow-up with implant revision for all cause failure as endpoint. Conclusion. The use of an optimal and consistent surgical technique and cementless implants can result in significant functional improvement, low complication rates, long-term implant survival, and high patient satisfaction following conversion of hip fusion to THA. The possibility of requiring a walking aid should be discussed with the patient before surgery. Cite this article: Bone Joint J 2021;103-B(7 Supple B):129–134


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 401 - 407
1 Mar 2005
Giannoudis PV Da Costa AA Raman R Mohamed AK Smith RM

Injury to the sciatic nerve is one of the more serious complications of acetabular fracture and traumatic dislocation of the hip, both in the short and long term. We have reviewed prospectively patients, treated in our unit, for acetabular fractures who had concomitant injury to the sciatic nerve, with the aim of predicting the functional outcome after these injuries. Of 136 patients who underwent stabilisation of acetabular fractures, there were 27 (19.9%) with neurological injury. At initial presentation, 13 patients had a complete foot-drop, ten had weakness of the foot and four had burning pain and altered sensation over the dorsum of the foot. Serial electromyography (EMG) studies were performed and the degree of functional recovery was monitored using the grading system of the Medical Research Council. In nine patients with a foot-drop, there was evidence of a proximal acetabular (sciatic) and a distal knee (neck of fibula) nerve lesion, the double-crush syndrome. At the final follow-up, clinical examination and EMG studies showed full recovery in five of the ten patients with initial muscle weakness, and complete resolution in all four patients with sensory symptoms (burning pain and hyperaesthesia). There was improvement of functional capacity (motor and sensory) in two patients who presented initially with complete foot-drop. In the remaining 11 with foot-drop at presentation, including all nine with the double-crush lesion, there was no improvement in function at a mean follow-up of 4.3 years


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1442 - 1448
1 Nov 2018
Hipfl C Janz V Löchel J Perka C Wassilew GI

Aims. Severe acetabular bone loss and pelvic discontinuity (PD) present particular challenges in revision total hip arthroplasty. To deal with such complex situations, cup-cage reconstruction has emerged as an option for treating this situation. We aimed to examine our success in using this technique for these anatomical problems. Patients and Methods. We undertook a retrospective, single-centre series of 35 hips in 34 patients (seven male, 27 female) treated with a cup-cage construct using a trabecular metal shell in conjunction with a titanium cage, for severe acetabular bone loss between 2011 and 2015. The mean age at the time of surgery was 70 years (42 to 85) and all patients had an acetabular defect graded as Paprosky Type 2C through to 3B, with 24 hips (69%) having PD. The mean follow-up was 47 months (25 to 84). Results. The cumulative five-year survivorship of the implant with revision for any cause was 89% (95% confidence interval (CI) 72 to 96) with eight hips at risk. No revision was required for aseptic loosening; however, one patient with one hip (3%) required removal of the ischial flange of the cage due to sciatic nerve irritation. Two patients (6%; two hips) suffered from hip dislocation, whereas one patient (one hip) required revision surgery with cement fixation of a dual-mobility acetababular component into a well-fixed cup-cage construct. Two patients (6%; two hips) developed periprosthetic infection. One patient was successfully controlled with a two-stage revision surgery, while the other patient underwent excision arthroplasty due to severe medical comorbidities. For the whole series, the Harris Hip Score significantly improved from a mean of 30 (15 to 51) preoperatively to 71 (40 to 89) at the latest follow-up (p < 0.001). Conclusion. Our findings suggest that cup-cage reconstruction is a viable option for major segmental bone defects involving the posterior column and PD. It allows adequate restoration of the acetabulum centre with generally good stability and satisfactory postoperative function. Instability and infection remain drawbacks in these challenging revision cases. Cite this article: Bone Joint J 2018;100-B:1442–48


The Journal of Bone & Joint Surgery British Volume
Vol. 58-B, Issue 2 | Pages 164 - 168
1 May 1976
Benson M Evans D

The medial displacement osteotomy of Chiari has an established place in the management of older children and adults with severe hip dysplasia. The results claimed for the operation are, however, variable. There have also been reports of sciatic nerve lesions. In this study ten cadavers were operated upon. Chiari osteotomy was performed upon five, and five acted as controls. The hemipelvis was removed from each cadaver; each specimen was deep-frozen and sectioned transversely. The distance of the sciatic nerve from the nearest bony point was measured in each section and the results were recorded graphically. A further radiographic and photographic study was performed to determine whether apparent displacement at the osteotomy might be misleading. The conclusion was drawn that the sciatic nerve is angulated at the osteotomy and further endangered by the risk of bone splintering at the sciatic notch. The radiographic study suggested that some poor clinical results may be explained by a radiological artefact, because there is a tendency for the osteotomy to hinge posteriorly at the sciatic notch opening anteriorly like a book. Radiographs may suggest excellent medial displacement whereas in fact the femoral head is very poorly covered


The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 636 - 641
1 May 2015
Kalhor M Gharehdaghi J Schoeniger R Ganz R

The modified Smith–Petersen and Kocher–Langenbeck approaches were used to expose the lateral cutaneous nerve of the thigh and the femoral, obturator and sciatic nerves in order to study the risk of injury to these structures during the dissection, osteotomy, and acetabular reorientation stages of a Bernese peri-acetabular osteotomy. Injury of the lateral cutaneous nerve of thigh was less likely to occur if an osteotomy of the anterior superior iliac spine had been carried out before exposing the hip. The obturator nerve was likely to be injured during unprotected osteotomy of the pubis if the far cortex was penetrated by > 5 mm. This could be avoided by inclining the osteotome 45° medially and performing the osteotomy at least 2 cm medial to the iliopectineal eminence. . The sciatic nerve could be injured during the first and last stages of the osteotomy if the osteotome perforated the lateral cortex of ischium and the ilio-ischial junction by > 10 mm. The femoral nerve could be stretched or entrapped during osteotomy of the pubis if there was significant rotational or linear displacement of the acetabulum. Anterior or medial displacement of < 2 cm and lateral tilt (retroversion) of < 30° were safe margins. The combination of retroversion and anterior displacement could increase tension on the nerve. Strict observation of anatomical details, proper handling of the osteotomes and careful manipulation of the acetabular fragment reduce the neurological complications of Bernese peri-acetabular osteotomy. Cite this article: Bone Joint J 2015;97-B:636–41


The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1345 - 1349
1 Oct 2015
Regev GJ Drexler M Sever R Dwyer T Khashan M Lidar Z Salame K Rochkind S

Sciatic nerve palsy following total hip arthroplasty (THA) is a relatively rare yet potentially devastating complication. The purpose of this case series was to report the results of patients with a sciatic nerve palsy who presented between 2000 and 2010, following primary and revision THA and were treated with neurolysis. A retrospective review was made of 12 patients (eight women and four men), with sciatic nerve palsy following THA. The mean age of the patients was 62.7 years (50 to 72; standard deviation 6.9). They underwent interfascicular neurolysis for sciatic nerve palsy, after failing a trial of non-operative treatment for a minimum of six months. Following surgery, a statistically and clinically significant improvement in motor function was seen in all patients. The mean peroneal nerve score function improved from 0.42 (0 to 3) to 3 (1 to 5) (p < 0.001). The mean tibial nerve motor function score improved from 1.75 (1 to 4) to 3.92 (3 to 5) (p = 0.02).The mean improvement in sensory function was a clinically negligible 1 out of 5 in all patients. In total, 11 patients reported improvement in their pain following surgery. . We conclude that neurolysis of the sciatic nerve has a favourable prognosis in patients with a sciatic nerve palsy following THA. Our findings suggest that surgery should not be delayed for > 12 months following injury. Cite this article: Bone Joint J 2015;97-B:1345–9


Bone & Joint 360
Vol. 3, Issue 1 | Pages 23 - 24
1 Feb 2014

The February 2014 Wrist & Hand Roundup. 360 . looks at: simple debridement and ulnar-sided wrist pain; needle fasciotomy or collagenase injection; joint replacement in osteoarthritic knuckles; the Mannerfelt arthrodesis; scaphoid union rates with conservative treatment; the benefits of atorvastatin for muscle re-innervation after sciatic nerve transection; and complications of trapeziectomy


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 1 | Pages 98 - 101
1 Jan 2008
Mannan K Altaf F Maniar S Tirabosco R Sinisi M Carlstedt T

We describe a case of sciatic endometriosis in a 25-year-old woman diagnosed by MRI and histology with no evidence of intrapelvic disease. The presentation, diagnosis and management of this rare condition are described. Early diagnosis and treatment are important to prevent irreversible damage to the sciatic nerve


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 4 | Pages 555 - 557
1 Apr 2011
Marchese M Sinisi M Anand P Di Mascio L Humphrey J

A 60-year-old man developed severe neuropathic pain and foot-drop in his left leg following resurfacing arthroplasty of the left hip. The pain was refractory to all analgesics for 16 months. At exploration, a PDS suture was found passing through the sciatic nerve at several points over 6 cm and terminating in a large knot. After release of the suture and neurolysis there was dramatic and rapid improvement of the neuropathic pain and of motor function. This case represents the human equivalent of previously described nerve ligation in an animal model of neuropathic pain. It emphasises that when neuropathic pain is present after an operation, the nerve related to the symptoms must be inspected, and that removal of a suture or irritant may lead to relief of pain, even after many months


Bone & Joint 360
Vol. 3, Issue 1 | Pages 46 - 46
1 Feb 2014

The February 2014 Research Roundup. 360 . looks at: blood supply to the femoral head after dislocation; diabetes and hip replacement; bone remodelling over two decades following hip replacement; sham surgery as good as arthroscopic meniscectomy; distraction in knee osteoarthritis; whether joint replacement prevent cardiac events; tranexamic acid and knee replacement haemostasis; cartilage colonisation in bipolar ankle grafts; CTs and proof of fusion; atorvastatin for muscle re-innervation after sciatic nerve transection; microfracture and short-term pain in cuff repair; promising early results from L-PRF augmented cuff repairs; and fatty degeneration in a rodent model


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 3 | Pages 471 - 473
1 May 1994
Aspden R Porter R

We report the case of a child with cerebral palsy and spastic diplegia treated for bilateral fixed flexion of the knee by bilateral hamstring lengthening. An attempt to straighten the legs from 90 degrees to 20 degrees flexion damaged the sciatic nerve. There are no objective means of estimating how much deformity can be reduced safely. We present a method of calculating the extra strain in the sciatic nerve produced by reducing a flexion deformity. The result, combined with clinical judgement, provides guidelines for safe corrective surgery


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 11 - 16
1 Nov 2013
Sierra RJ Mabry TM Sems SA Berry DJ

Total hip replacement (THR) after acetabular fracture presents unique challenges to the orthopaedic surgeon. The majority of patients can be treated with a standard THR, resulting in a very reasonable outcome. Technical challenges however include infection, residual pelvic deformity, acetabular bone loss with ununited fractures, osteonecrosis of bone fragments, retained metalwork, heterotopic ossification, dealing with the sciatic nerve, and the difficulties of obtaining long-term acetabular component fixation. Indications for an acute THR include young patients with both femoral head and acetabular involvement with severe comminution that cannot be reconstructed, and the elderly, with severe bony comminution. The outcomes of THR for established post-traumatic arthritis include excellent pain relief and functional improvements. The use of modern implants and alternative bearing surfaces should improve outcomes further. Cite this article: Bone Joint J 2013;95-B, Supple A:11–16


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1373 - 1378
1 Oct 2006
Debnath UK Guha AR Karlakki S Varghese J Evans GA

In order to treat painful subluxation or dislocation secondary to cerebral palsy, 11 patients (12 hips) underwent combined femoral and Chiari pelvic osteotomies with additional soft-tissue releases at a mean age of 14.1 years (9.1 to 17.8). Relief of pain, improvement in movement of the hip, and in sitting posture, and ease of perineal care were recorded in all, and were maintained at a mean follow-up of 13.1 years (8 to 17.5). The improvement in general mobility was marginal, but those who were able to walk benefited the most. The radiological measurements made before operation were modified afterwards to use the lateral margin of the neoacetabulum produced by the pelvic osteotomy. The radiological migration index improved from a mean of 80.6% (61% to 100%) to 13.7% (0% to 33%) (p < 0.0001). The mean changes in centre edge angle and Sharp’s angle were 72° (56° to 87°; p < 0.0001) and 12.3° (9° to 15.6°; p < 0.0001), respectively. Radiological evidence of progressive arthritic change was seen in one hip, in which only a partial reduction had been achieved, and there was early narrowing of the joint space in another. Painless heterotopic ossification was observed in one patient with athetoid quadriplegia. In seven hips the lateral Kawamura approach, elevating the greater trochanter, provided exposure for both osteotomies and allowed the construction of a dome-shaped iliac osteotomy, while protecting the sciatic nerve


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 11 | Pages 1562 - 1567
1 Nov 2011
Wells-Cole E Griffiths A Fines D Zenios M

This retrospective study compared post-operative epidural analgesia (E), continuous peripheral nerve blocks (CPNB) and morphine infusion (M) in 68 children undergoing limb reconstruction with circular frames. The data collected included episodes of severe pain, post-operative duration of analgesia, requirement for top-up analgesia, number of osteotomies, side effects and complications. There was a significant difference between the number of episodes of severe pain in patients receiving a morphine infusion and those receiving epidurals or CPNB (M vs E, p < 0.0001; M vs CPNB, p = 0.018). The CPNB group was associated with the lowest incidence of episodes of severe pain and top-up analgesia. Epidural analgesia was associated with significantly more nausea and vomiting than morphine infusion (p = 0.053) and CPNB (p = 0.023). It also had a significantly higher incidence of motor blockade than CPNB (p < 0.01). We found that the most effective method of post-operative analgesia for children undergoing lower limb reconstruction was sciatic nerve catheterisation and continuous infusion


Bone & Joint Open
Vol. 5, Issue 9 | Pages 776 - 784
19 Sep 2024
Gao J Chai N Wang T Han Z Chen J Lin G Wu Y Bi L

Aims

In order to release the contracture band completely without damaging normal tissues (such as the sciatic nerve) in the surgical treatment of gluteal muscle contracture (GMC), we tried to display the relationship between normal tissue and contracture bands by magnetic resonance neurography (MRN) images, and to predesign a minimally invasive surgery based on the MRN images in advance.

Methods

A total of 30 patients (60 hips) were included in this study. MRN scans of the pelvis were performed before surgery. The contracture band shape and external rotation angle (ERA) of the proximal femur were also analyzed. Then, the minimally invasive GMC releasing surgery was performed based on the images and measurements, and during the operation, incision lengths, surgery duration, intraoperative bleeding, and complications were recorded; the time of the first postoperative off-bed activity was also recorded. Furthermore, the patients’ clinical functions were evaluated by means of Hip Outcome Score (HOS) and Ye et al’s objective assessments, respectively.


The Journal of Bone & Joint Surgery British Volume
Vol. 62-B, Issue 4 | Pages 506 - 507
1 Nov 1980
Jones B Ward M

A case of bilateral myositis ossificans in the biceps femoris muscles causing a sciatic nerve palsy on the left side is described. Complete recovery of the sciatic nerve followed excision of the mass of ectopic bone. It is postulated that the patient's hobby of weight-lifting caused the ossification


The Journal of Bone & Joint Surgery British Volume
Vol. 31-B, Issue 2 | Pages 222 - 226
1 May 1949
Foley WB

1. An operation is described for ischio-femoral extra-articular arthrodesis of the hip joint by posterior open approach, based on the techniques of Trumble and Brittain. 2. The operation has the advantages of affording adequate exposure of the sciatic nerve trunk and permitting visual control of the alignment and penetration of the chisel and graft. 3. The operation has been performed successfully without serious shock or subsequent complications in eighteen cases, mostly of tuberculosis of the hip


The Journal of Bone & Joint Surgery British Volume
Vol. 32-B, Issue 1 | Pages 42 - 47
1 Feb 1950
Fahrni WH

1. It is possible that neonatal sciatic palsy occurs more often than is suggested by perusal of the literature: paralysis of a foot may easily be overlooked in the new-born infant; it may be regarded as a temporary paresis due to mild birth trauma; or in later months it may be attributed to poliomyelitis. 2. Eleven cases of neonatal sciatic palsy are reported. Autopsy in one suggested that the paralysis was due to direct pressure on the sciatic nerve before birth. 3. A hypothesis is advanced by which to explain how pressure on the nerve trunk may arise in utero


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 3 | Pages 379 - 382
1 May 1989
Martini A Fromm B

A stump neuroma is caused by the disorganised growth of axon cylinders into proliferating granulation tissue, but this is stopped by an undamaged epineural sleeve. We report experiments in the rat in which the epineural sleeve of the stump of the sciatic nerve was freed from nerve fascicles for about 5 mm and then sealed with a synthetic tissue adhesive. Neuroma formation was largely prevented in comparison with the results of other methods. This new technique has been used to treat 68 painful neuromas in 36 patients. All but three of the patients were cured or improved and none were made worse


The Journal of Bone & Joint Surgery British Volume
Vol. 41-B, Issue 2 | Pages 355 - 357
1 May 1959
Champion R Cregan JCF

The early management of bilateral congenital popliteal webbing in a brother and sister is described. There was no familial history of webbing, but the maternal grandfather had a hare-lip. Although the sciatic nerve is so unfavourably placed in the web, correction of the flexion deformity can apparently be carried out safely after plastic repair of the skin by Z-plasty and excision of the fibrous web cord alone, without causing a traction paralysis. These cases appear to be unique in that the patients are siblings of different sex with identical congenital abnormalities of bilateral webbing, cleft palate and fistulae of the mucous membrane of the lower lip


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 2 | Pages 315 - 318
1 Mar 1988
Garces G Santandreu M

The right sciatic nerve of 50 one-month-old male rats was cut under general anaesthesia. Groups of animals were sacrificed at intervals of up to 12 weeks after operation and the length of the femora, tibiae and first and fifth metatarsals were measured with a caliper accurate to 0.05 mm. From the first week, both metatarsals were between 3% and 5% shorter on the denervated side, but there was no further increase of the discrepancy. The femora were less than 1% longer in the denervated limb at the second and eighth week. No difference was found between the lengths of the tibiae. The various factors which could possibly be responsible for these findings are discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 59-B, Issue 3 | Pages 323 - 330
1 Aug 1977
Duncan C Shim S

The anatomy of the autonomic sympathetic vasomotor nerve supply of bone was studied in rabbits by methods of histochemistry, and fluorescent and electron microscopy. Our observations show that the intraosseous vessels are richly supplied by adrenergic nerves. The large primary nerves are located on or about the surface of the vessel; the medium sized secondary nerves spiral around the long axis of vessels lying more deeply in the tunica adventitia; and the fine tertiary nerves form a rich plexus at the outer area of the tunica media. The tertiary nerves have various structures which probably contain neurotransmitter substance--that is, noradrenaline--and function as neuro-vasomuscular synapses. The sympathetic nerve supply of bone originates from the appropriate ganglion, and in the case of the tibial diaphysis it descends through the sciatic nerve and thereafter mainly through the medial popliteal nerve and enters the bone alongside the nutrient artery


Bone & Joint 360
Vol. 12, Issue 3 | Pages 32 - 35
1 Jun 2023

The June 2023 Trauma Roundup360 looks at: Aspirin or low-molecular-weight heparin for thromboprophylaxis?; Lateral plating or retrograde nailing for distal femur fractures?; Sciatic nerve palsy after acetabular fixation: what about patient position?; How reliable is the new OTA/AO classification for trochanteric hip fractures?; Young hip fractures: is a medial buttress the answer?; When is the best time to ‘flap’ an open fracture?; The mortality burden of nonoperatively managed hip fractures.


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1093 - 1099
1 Oct 2024
Ferreira GF Lewis TL Fernandes TD Pedroso JP Arliani GG Ray R Patriarcha VA Filho MV

Aims

A local injection may be used as an early option in the treatment of Morton’s neuroma, and can be performed using various medications. The aim of this study was to compare the effects of injections of hyaluronic acid compared with corticosteroid in the treatment of this condition.

Methods

A total of 91 patients were assessed for this trial, of whom 45 were subsequently included and randomized into two groups. One patient was lost to follow-up, leaving 22 patients (24 feet) in each group. The patients in the hyaluronic acid group were treated with three ultrasound-guided injections (one per week) of hyaluronic acid (Osteonil Plus). Those in the corticosteroid group were treated with three ultrasound-guided injections (also one per week) of triamcinolone (Triancil). The patients were evaluated before treatment and at one, three, six, and 12 months after treatment. The primary outcome measure was the visual analogue scale for pain (VAS). Secondary outcome measures included the American Orthopaedic Foot and Ankle Society (AOFAS) score, and complications.


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 6 | Pages 899 - 902
1 Nov 1996
Weale AE Newman P Ferguson IT Bannister GC

Nerve injury is a rare complication of total hip replacement which may be related to the exposure used for the operation. The posterior approach is traditionally associated with injury to the sciatic nerve. We have compared the incidence of nerve injury after primary total hip replacement (THR) using either a posterior or a direct lateral approach. We studied 42 consecutive patients undergoing primary total hip replacement. The surgeons used a posterior (22 patients) or direct lateral (20 patients) approach in accordance with their normal practice. The obturator, femoral, posterior tibial and common peroneal nerves were assessed clinically and electrophysiologically by electromyography (EMG) and measurement of the velocity of nerve conduction before operation and at four weeks after. All patients were free from symptoms of nerve injury after operation but five lesions were identified in four patients by the electrophysiological studies; the obturator nerve was involved in two, the femoral in one, the common peroneal in one and the posterior tibial in one. All these injuries occurred using the lateral approach. Clinical assessment alone underestimates the incidence of nerve injury complicating THR. Our study does not confirm the association of nerve injury with the posterior approach which had been described previously


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 124 - 134
1 Feb 2023
Jain S Farook MZ Aslam-Pervez N Amer M Martin DH Unnithan A Middleton R Dunlop DG Scott CEH West R Pandit H

Aims

The aim of this study was to compare open reduction and internal fixation (ORIF) with revision surgery for the surgical management of Unified Classification System (UCS) type B periprosthetic femoral fractures around cemented polished taper-slip femoral components following primary total hip arthroplasty (THA).

Methods

Data were collected for patients admitted to five UK centres. The primary outcome measure was the two-year reoperation rate. Secondary outcomes were time to surgery, transfusion requirements, critical care requirements, length of stay, two-year local complication rates, six-month systemic complication rates, and mortality rates. Comparisons were made by the form of treatment (ORIF vs revision) and UCS type (B1 vs B2/B3). Kaplan-Meier survival analysis was performed with two-year reoperation for any reason as the endpoint.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 8 | Pages 1156 - 1161
1 Nov 2002
Chen WM Chen TH Huang CK Chiang CC Lo WH

Autogenous bone graft which has been either autoclaved or irradiated is commonly used in oriental countries as an alternative to allograft. We started to use the technique of extracorporeal irradiation of the resected specimen and reimplantation (ECIR) in 1991. There was, however, a high incidence of fracture of the irradiated bone and loss of articular cartilage. In an attempt to reduce these complications, we combined the irradiated autograft with a conventional arthroplasty. Between 1995 and 1998, 14 patients underwent limb salvage by this method. Seven had an osteosarcoma, two bony metastases, three a chondrosarcoma, one a malignant fibrous histiocytoma, and one a leiomyosarcoma. Ten tumours were located in the proximal femur, two in the proximal humerus, and two in the distal femur. One patient who had a solitary metastasis in the proximal part of the left femur died from lung metastases 13 months after operation. The remaining 13 patients were alive and without evidence of local recurrence or distant metastases at a mean follow-up of 43 months (28 to 72). Postoperative palsy of the sciatic nerve occurred in one patient, but no complications such as wound infection, fracture, or nonunion were seen. All host-irradiated bone junctions healed uneventfully within eight months. Using the Enneking functional evaluation system, the mean postoperative score for all 14 patients was 80% (57 to 93). The use of irradiated autograft prosthesis composites reduces the complications of ECIR and gives good functional results. It may be a good alternative in limb-salvage surgery, especially in countries where it is difficult to obtain allografts


Bone & Joint Open
Vol. 3, Issue 4 | Pages 314 - 320
7 Apr 2022
Malhotra R Batra S Sugumar PA Gautam D

Aims

Adult patients with history of childhood infection pose a surgical challenge for total hip arthroplasty (THA) due to distorted bony anatomy, soft-tissue contractures, risk of reinfection, and relatively younger age. Therefore, the purpose of the present study was to determine clinical outcome, reinfection rate, and complications in patients with septic sequelae after THA.

Methods

A retrospective analysis was conducted of 91 cementless THAs (57 male and 34 female) performed between 2008 and 2017 in patients who had history of hip infection during childhood. Clinical outcome was measured using Harris Hip Score (HHS) and Modified Merle d’Aubigne and Postel (MAP) score, and quality of life (QOL) using 12-Item Short Form Health Survey Questionnaire (SF-12) components: Physical Component Score (PCS) and Mental Component Score (MCS); limb length discrepancy (LLD) and radiological assessment of the prosthesis was performed at the latest follow-up. Reinfection and revision surgery after THA for any reason was documented.