Advertisement for orthosearch.org.uk
Results 1 - 50 of 1273
Results per page:
Bone & Joint Research
Vol. 1, Issue 7 | Pages 152 - 157
1 Jul 2012
Hamilton DF Gatherer D Jenkins PJ Maclean JGB Hutchison JD Nutton RW Simpson AHRW

Objectives. To evaluate the neck strength of school-aged rugby players, and to define the relationship with proxy physical measures with a view to predicting neck strength. Methods. Cross-sectional cohort study involving 382 rugby playing schoolchildren at three Scottish schools (all male, aged between 12 and 18 years). Outcome measures included maximal isometric neck extension, weight, height, grip strength, cervical range of movement and neck circumference. Results. Mean neck extension strength increased with age (p = 0.001), although a wide inter-age range variation was evident, with the result that some of the oldest children presented with the same neck strength as the mean of the youngest group. Grip strength explained the most variation in neck strength (R. 2. = 0.53), while cervical range of movement and neck girth demonstrated no relationship. Multivariable analysis demonstrated the independent effects of age, weight and grip strength, and the resultant model explained 62.1% of the variance in neck strength. This model predicted actual neck strength well for the majority of players, although there was a tendency towards overestimation at the lowest range and underestimation at the highest. Conclusion. A wide variation was evident in neck strength across the range of the schoolchild-playing population, with a surprisingly large number of senior players demonstrating the same mean strength as the 12-year-old mean value. This may suggest that current training regimes address limb strength but not neck strength, which may be significant for future neck injury prevention strategies. Age, weight and grip strength can predict around two thirds of the variation in neck strength, however specific assessment is required if precise data is sought


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1011 - 1021
1 Aug 2013
Krishnan H Krishnan SP Blunn G Skinner JA Hart AJ

Following the recall of modular neck hip stems in July 2012, research into femoral modularity will intensify over the next few years. This review aims to provide surgeons with an up-to-date summary of the clinically relevant evidence. The development of femoral modularity, and a classification system, is described. The theoretical rationale for modularity is summarised and the clinical outcomes are explored. The review also examines the clinically relevant problems reported following the use of femoral stems with a modular neck. Joint replacement registries in the United Kingdom and Australia have provided data on the failure rates of modular devices but cannot identify the mechanism of failure. This information is needed to determine whether modular neck femoral stems will be used in the future, and how we should monitor patients who already have them implanted. Cite this article: Bone Joint J 2013;95-B:1011–21


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 964 - 969
1 Sep 2024
Wang YC Song JJ Li TT Yang D Lv ZB Wang ZY Zhang ZM Luo Y

Aims. To propose a new method for evaluating paediatric radial neck fractures and improve the accuracy of fracture angulation measurement, particularly in younger children, and thereby facilitate planning treatment in this population. Methods. Clinical data of 117 children with radial neck fractures in our hospital from August 2014 to March 2023 were collected. A total of 50 children (26 males, 24 females, mean age 7.6 years (2 to 13)) met the inclusion criteria and were analyzed. Cases were excluded for the following reasons: Judet grade I and Judet grade IVb (> 85° angulation) classification; poor radiograph image quality; incomplete clinical information; sagittal plane angulation; severe displacement of the ulna fracture; and Monteggia fractures. For each patient, standard elbow anteroposterior (AP) view radiographs and corresponding CT images were acquired. On radiographs, Angle P (complementary to the angle between the long axis of the radial head and the line perpendicular to the physis), Angle S (complementary to the angle between the long axis of the radial head and the midline through the proximal radial shaft), and Angle U (between the long axis of the radial head and the straight line from the distal tip of the capitellum to the coronoid process) were identified as candidates approximating the true coronal plane angulation of radial neck fractures. On the coronal plane of the CT scan, the angulation of radial neck fractures (CTa) was measured and served as the reference standard for measurement. Inter- and intraobserver reliabilities were assessed by Kappa statistics and intraclass correlation coefficient (ICC). Results. Angle U showed the strongest correlation with CTa (p < 0.001). In the analysis of inter- and intraobserver reliability, Kappa values were significantly higher for Angles S and U compared with Angle P. ICC values were excellent among the three groups. Conclusion. Angle U on AP view was the best substitute for CTa when evaluating radial neck fractures in children. Further studies are required to validate this method. Cite this article: Bone Joint J 2024;106-B(9):964–969


Bone & Joint Research
Vol. 10, Issue 12 | Pages 780 - 789
1 Dec 2021
Eslam Pour A Lazennec JY Patel KP Anjaria MP Beaulé PE Schwarzkopf R

Aims. In computer simulations, the shape of the range of motion (ROM) of a stem with a cylindrical neck design will be a perfect cone. However, many modern stems have rectangular/oval-shaped necks. We hypothesized that the rectangular/oval stem neck will affect the shape of the ROM and the prosthetic impingement. Methods. Total hip arthroplasty (THA) motion while standing and sitting was simulated using a MATLAB model (one stem with a cylindrical neck and one stem with a rectangular neck). The primary predictor was the geometry of the neck (cylindrical vs rectangular) and the main outcome was the shape of ROM based on the prosthetic impingement between the neck and the liner. The secondary outcome was the difference in the ROM provided by each neck geometry and the effect of the pelvic tilt on this ROM. Multiple regression was used to analyze the data. Results. The stem with a rectangular neck has increased internal and external rotation with a quatrefoil cross-section compared to a cone in a cylindrical neck. Modification of the cup orientation and pelvic tilt affected the direction of projection of the cone or quatrefoil shape. The mean increase in internal rotation with a rectangular neck was 3.4° (0° to 7.9°; p < 0.001); for external rotation, it was 2.8° (0.5° to 7.8°; p < 0.001). Conclusion. Our study shows the importance of attention to femoral implant design for the assessment of prosthetic impingement. Any universal mathematical model or computer simulation that ignores each stem’s unique neck geometry will provide inaccurate predictions of prosthetic impingement. Cite this article: Bone Joint Res 2021;10(12):780–789


Bone & Joint Open
Vol. 2, Issue 8 | Pages 611 - 617
10 Aug 2021
Kubik JF Bornes TD Klinger CE Dyke JP Helfet DL

Aims. Surgical treatment of young femoral neck fractures often requires an open approach to achieve an anatomical reduction. The application of a calcar plate has recently been described to aid in femoral neck fracture reduction and to augment fixation. However, application of a plate may potentially compromise the regional vascularity of the femoral head and neck. The purpose of this study was to investigate the effect of calcar femoral neck plating on the vascularity of the femoral head and neck. Methods. A Hueter approach and capsulotomy were performed bilaterally in six cadaveric hips. In the experimental group, a one-third tubular plate was secured to the inferomedial femoral neck at 6:00 on the clockface. The contralateral hip served as a control with surgical approach and capsulotomy without fixation. Pre- and post-contrast MRI was then performed to quantify signal intensity in the femoral head and neck. Qualitative assessment of the terminal arterial branches to the femoral head, specifically the inferior retinacular artery (IRA), was also performed. Results. Quantitative MRI revealed a mean reduction of 1.8% (SD 3.1%) of arterial contribution in the femoral head and a mean reduction of 7.1% (SD 10.6%) in the femoral neck in the plating group compared to non-plated controls. Based on femoral head quadrant analysis, the largest mean decrease in arterial contribution was in the inferomedial quadrant (4.0%, SD 6.6%). No significant differences were found between control and experimental hips for any femoral neck or femoral head regions. The inferior retinaculum of Weitbrecht (containing the IRA) was directly visualized in six of 12 specimens. Qualitative MRI assessment confirmed IRA integrity in all specimens. Conclusion. Calcar femoral neck plating at the 6:00 position on the clockface resulted in minimal decrease in femoral head and neck vascularity, and therefore it may be considered as an adjunct to laterally-based fixation for reduction and fixation of femoral neck fractures, especially in younger patients. Cite this article: Bone Jt Open 2021;2(8):611–617


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 461 - 467
1 Apr 2018
Wagener J Schweizer C Zwicky L Horn Lang T Hintermann B

Aims. Arthroscopically controlled fracture reduction in combination with percutaneous screw fixation may be an alternative approach to open surgery to treat talar neck fractures. The purpose of this study was thus to present preliminary results on arthroscopically reduced talar neck fractures. Patients and Methods. A total of seven consecutive patients (four women and three men, mean age 39 years (19 to 61)) underwent attempted surgical treatment of a closed Hawkins type II talar neck fracture using arthroscopically assisted reduction and percutaneous screw fixation. Functional and radiological outcome were assessed using plain radiographs, as well as weight-bearing and non-weight-bearing CT scans as tolerated. Patient satisfaction and pain sensation were also recorded. Results. Primary reduction was obtained arthroscopically in all but one patient, for whom an interposed fracture fragment had to be removed through a small arthrotomy to permit anatomical reduction. The quality of arthroscopic reduction and restoration of the talar geometry was excellent in the remaining six patients. There were no signs of talar avascular necrosis or subtalar degeneration in any of the patients. In the whole series, the functional outcome was excellent in five patients but restricted ankle movement was observed in two patients. All patients had a reduction in subtalar movement. At final follow-up, all patients were satisfied and all but one patient were pain free. Conclusion. Arthroscopically assisted reduction and fixation of talar neck fractures was found to be a feasible treatment option and allowed early functional rehabilitation. Cite this article: Bone Joint J 2018;100-B:461–7


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 223 - 228
1 Feb 2011
Neumann M Nyffeler R Beck M

Mason type III fractures of the radial head are treated by open reduction and internal fixation, resection or prosthetic joint replacement. When internal fixation is performed, fixation of the radial head to the shaft is difficult and implant-related complications are common. Furthermore, problems of devascularisation of the radial head can result from fixation of the plate to the radial neck. In a small retrospective study, the treatment of Mason type III fractures with fixation of the radial neck in 13 cases (group 2) was compared with 12 cases where no fixation was performed (group 1). The mean clinical and radiological follow-up was four years (1 to 9). The Broberg-Morrey index showed excellent results in both groups. Degenerative radiological changes were seen more frequently in group 2, and removal of the implant was necessary in seven of 13 cases. Post-operative evaluation of these two different techniques revealed similar ranges of movement and functional scores. We propose that anatomical reconstruction of the radial head without metalwork fixation to the neck is preferable, and the outcome is the same as that achieved with the conventional technique. In addition degenerative changes of the elbow joint may develop less frequently, and implant removal is not necessary


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 9 - 15
1 Jan 2007
Beaulé PE Harvey N Zaragoza E Le Duff MJ Dorey FJ

Because the femoral head/neck junction is preserved in hip resurfacing, patients may be at greater risk of impingement, leading to abnormal wear patterns and pain. We assessed femoral head/neck offset in 63 hips undergoing metal-on-metal hip resurfacing and in 56 hips presenting with non-arthritic pain secondary to femoroacetabular impingement. Most hips undergoing resurfacing (57%; 36) had an offset ratio ≤ 0.15 pre-operatively and required greater correction of offset at operation than the rest of the group. In the non-arthritic hips the mean offset ratio was 0.137 (0.04 to 0.23), with the offset ratio correlating negatively to an increasing α angle. An offset ratio ≤ 0.15 had a 9.5-fold increased relative risk of having an α angle ≥ 50.5°. Most hips undergoing resurfacing have an abnormal femoral head/neck offset, which is best assessed in the sagittal plane


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 8 | Pages 1019 - 1024
1 Aug 2007
Hing CB Young DA Dalziel RE Bailey M Back DL Shimmin AJ

Narrowing of the femoral neck after resurfacing arthroplasty of the hip has been described previously in both cemented and uncemented hip resurfacing. The natural history of narrowing of the femoral neck is unknown. We retrospectively measured the diameter of the femoral neck in a series of 163 Birmingham hip resurfacings in 163 patients up to a maximum of six years after operation to determine the extent and progression of narrowing. There were 105 men and 58 women with a mean age of 52 years (18 to 82). At a mean follow-up of five years, the mean Harris hip score was 94.8 (47 to 100) and the mean flexion of the hip 112.5° (80° to 160°). There was some narrowing of the femoral neck in 77% (125) of the patients reviewed, and in 27.6% (45) the narrowing exceeded 10% of the diameter of the neck. A multiple logistic regression analysis showed a significant association (chi-squared test (derived from logistic regression) p = 0.01) of narrowing with female gender and a valgus femoral neck/shaft angle. There was no significant association between the range of movement, position or size of the component or radiological lucent lines and narrowing of the neck (chi-squared test; p = 0.10 (flexion), p = 0.08 (size of femoral component), p = 0.09 (size of acetabular component), p = 0.71 (femoral component angulation), p = 0.99 (lucent lines)). There was no significant difference between the diameter of the neck at a mean of three years (2.5 to 3.5) and that at five years (4.5 to 5.5), indicating that any change in the diameter of the neck had stabilised by three years (sign rank test, p = 0.60). We conclude that narrowing of the femoral neck which is found with the Birmingham hip resurfacing arthroplasty is in most cases associated with no adverse clinical or radiological outcome up to a maximum of six years after the initial operation


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1263 - 1271
1 Oct 2019
Eisenschenk A Spitzmüller R Güthoff C Obladen A Kim S Henning E Dornberger JE Stengel D

Aims. The aim of this study was to investigate whether clinical and radiological outcomes after intramedullary nailing of displaced fractures of the fifth metacarpal neck using a single thick Kirschner wire (K-wire) are noninferior to those of technically more demanding fixation with two thinner dual wires. Patients and Methods. This was a multicentre, parallel group, randomized controlled noninferiority trial conducted at 12 tertiary trauma centres in Germany. A total of 290 patients with acute displaced fractures of the fifth metacarpal neck were randomized to either intramedullary single-wire (n = 146) or dual-wire fixation (n = 144). The primary outcome was the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire six months after surgery, with a third of the minimal clinically important difference (MCID) used as the noninferiority threshold. Secondary outcomes were pain, health-related quality of life (EuroQol five-dimensional questionnaire (EQ-5D)), radiological measures, functional deficits, and complications. Results. Overall, 151/290 of patients (52%) completed the six months of follow-up, leaving 83 patients in the single-wire group and 68 patients in the dual-wire group. In the modified intention-to-treat analysis set, mean DASH scores six months after surgery were 3.8 (. sd. 7.0) and 4.4 (. sd. 9.4), respectively. With multiple imputation (n = 288), mean DASH scores were estimated at 6.3 (. sd. 8.7) and 7.0 (. sd. 10.0). Upper (1 - 2α)) confidence limits consistently remained below the noninferiority margin of 3.0 points in the DASH instrument. While there was a statistically nonsignificant trend towards a higher rate of shortening and rotational malalignment in the single wire group, no statistically significant differences were observed across groups in any secondary outcome measure. Conclusion. A single thick K-wire is sufficient for intramedullary fixation of acute displaced subcapital fractures of the fifth metacarpal neck. The less technically demanding single-wire technique produces noninferior clinical and radiological outcomes compared with the dual-wire approach. Cite this article: Bone Joint J 2019;101-B:1263–1271


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 4 | Pages 442 - 445
1 Apr 2008
Amarasekera HW Costa ML Foguet P Krikler SJ Prakash U Griffin DR

We used Laser Doppler flowmetry to measure the effect on the blood flow to the femoral head/neck junction of two surgical approaches during resurfacing arthroplasty. We studied 24 hips undergoing resurfacing arthroplasty for osteoarthritis. Of these, 12 had a posterior approach and 12 a trochanteric flip approach. A Laser probe was placed under radiological control in the superolateral part of the femoral head/neck junction. The Doppler flux was measured at stages of the operation and compared with the initial flux. In both groups the main fall in blood flow occurred during the initial exposure and capsulotomy of the hip joint. There was a greater reduction in blood flow with the posterior (40%) than with the trochanteric flip approach (11%)


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 830 - 835
1 Jun 2015
Li SL Lu Y Wang MY

This study compares the outcomes of two methods of fixation of displaced fractures of the radial neck. The 58 patients with a mean age of 38.5 years (18 to 56), were treated in a non randomised study with screws (n = 29) or a plate and screws (n = 29) according to the surgeon’s preference. The patients were reviewed at one year. Radiographs and functional evaluations were carried out up to one year post-operatively, using the Broberg and Morrey functional evaluation score, range of movement, and assessment of complications. The mean functional scores did not differ significantly between groups (90 (55 to 100) vs 84; 50 to 100, p = 0.09), but the mean range of forearm rotation in screw group was significantly better than in the plate group (152°; 110° to 170° vs 134°; 80° to 170°, p = 0.001). Although not statistically significant, the screw group had a lower incidence of heterotopic ossification than the plate group (n = 1) than the plated group (n = 3) and the pathology was graded as less severe. Cite this article: Bone Joint J 2015;97-B:830–5


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 4 | Pages 536 - 541
1 May 2001
Stiefel D Meuli M Altermatt S

The treatment of fractures of the neck of the radius in children is difficult, particularly if the angulation of the fracture exceeds 60°. Since 1994 we have used closed reduction and stabilisation with an intramedullary Kirschner wire in patients with grade-IV fractures according to the classification of Judet et al. In a retrospective analysis of a two-year period (1994 to 1996), 324 children with fractures of the elbow were treated in our department. Of these, 29 (9%) had a fracture of the neck of the radius; six were grade-IV injuries (1.9%). Five of the latter had an excellent postoperative result with normal movement of the elbow and forearm. One patient with a poor result had a concomitant dislocation of the elbow. Our results suggest that closed reduction and intramedullary pinning of grade-IV fractures allows adequate stabilisation while healing occurs


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 5 | Pages 642 - 644
1 May 2006
åkesson T Herbertsson P Josefsson P Hasserius R Besjakov J Karlsson MK

We have reviewed 20 women and three men aged 22 to 73 years, who had sustained a Mason type-IIb fracture of the neck of the radius 14 to 25 years earlier. There were 19 patients with displacement of the fractures of 2 mm to 4 mm, of whom 13 had been subjected to early mobilisation and six had been treated in plaster for one to four weeks. Of four patients with displacement of 4 mm to 8 mm, three had undergone excision and one an open reduction of the head of radius. A total of 21 patients had no subjective complaints at follow-up, but two had slight impairment and occasional elbow pain. The mean range of movement and strength of the elbow were not impaired. The elbows had a higher prevalence of degenerative changes than the opposite side, but no greater reduction of joint space. Mason type-IIb fractures have an excellent long-term outcome if operation is undertaken when the displacement of the fracture exceeds 4 mm


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 5 | Pages 901 - 903
1 Sep 1990
Gargan M Bannister G

We reviewed 43 patients who had sustained soft-tissue injuries of the neck after a mean 10.8 years. Of these, only 12% had recovered completely. Residual symptoms were intrusive in 28% and severe in 12%. Pain in the neck and lower back was the commonest complaint and older patients had a worse prognosis. After two years, symptoms did not alter with further passage of time


The Journal of Bone & Joint Surgery British Volume
Vol. 53-B, Issue 3 | Pages 429 - 439
1 Aug 1971
Jones ERL Esah M

1. Thirty-four cases of displaced fracture of the neck of the radius in children are reviewed with special reference to elbow and forearm function. 2. There were eight poor functional results-four after eighteen closed reductions and four after sixteen open reductions. 3. The causes of the poor functional results are recorded and the complications discussed. Union in a displaced position was the main cause of restricted movement. Deformity of the radial head due to avascular necrosis, and fibrous adhesions between the neck of the radius and the ulna, were other factors. 4. Fractures that were held reduced by Kirschner wires had better results than comparable fractures treated by closed reduction or op en reduction without fixation. 5. It is concluded that all fractures, whatever the age of the child, with angular displacement exceeding 15 degrees need accurate reduction. Closed reduction is not easy, and repeated check radiographs are needed to ensure maintenance of reduction. Certain of these fractures are unstable and require internal fixation with Kirschner wires


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 2 | Pages 273 - 274
1 Mar 2003
Hennrikus WL Cohen MR

Fractures of the neck of the phalanx of the finger are uncommon, but problematic, injuries in children. Displaced fractures may heal with malunion leading to loss of movement or angular deformity. Remodelling of the phalangeal neck is reported to be minimal because of the distance of the fracture from the physis. We report three displaced fractures in two children who presented late. The fractures were treated conservatively and remodelled completely. Both patients regained full movement of the fingers


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 3 | Pages 426 - 430
1 Apr 2002
Huber H Galantay R Dutoit M

In order to determine the incidence of avascular necrosis after osteotomy of the talar neck, we re-evaluated 11 patients (16 feet) with idiopathic club foot who had undergone this procedure at a mean age of eight years (5 to 13) to correct a residual adduction deformity. All had been initially treated conservatively and operatively. The mean follow-up was 39 years (36 to 41). Surgery consisted of a closing-wedge osteotomy of the talar neck combined, in 14 feet, with lengthening of the first cuneiform and a Steindler procedure. At follow-up eight feet were free from pain, three had occasional mild pain and five were regularly painful after routine activities. Two patients were unlimited in their activity, six occasionally limited after strenuous and three regularly limited after strenuous activity. Using the Ponseti score, the feet were rated as good in four, fair in three and poor in nine. In seven feet avascular necrosis with collapse and flattening of the talar dome had occurred. In all of these feet the children were younger than ten years of age at the time of surgery. In three feet, avascular necrosis of the talar head was also observed. We conclude that osteotomy of the talar neck in children under the age of ten years can cause avascular necrosis and should be abandoned


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 7 | Pages 1028 - 1031
1 Jul 2010
Chouhan V Agrawal K Vinothkumar TK Mathesul A

We describe a case of oncogenic osteomalacia in an adult male who presented with low back pain and bilateral hip pain. Extensive investigations had failed to find a cause. A plain pelvic radiograph showed Looser’s zones in both femoral necks. MRI confirmed the presence of insufficiency fractures bilaterally in the femoral head and neck. Biochemical investigations confirmed osteomalacia which was unresponsive to treatment with vitamin D and calcium. A persistently low serum phosphate level suggested a diagnosis of hypophosphataemic osteomalacia. The level of fibroblast growth factor-23 was highly raised, indicating the cause as oncogenic osteomalacia. This was confirmed on positron-emission tomography, MRI and excision of a benign fibrous histiocytoma following a rapid recovery. The diagnosis of oncogenic osteomalacia may be delayed due to the non-specific presenting symptoms. Subchondral insufficiency fractures of the femoral head may be missed unless specifically looked for


The Journal of Bone & Joint Surgery British Volume
Vol. 36-B, Issue 1 | Pages 57 - 61
1 Feb 1954
Berkin CR Hirson C

1. The clinical and post-mortem findings are described of a patient who sustained a hyperextension injury of the neck with paraplegia. 2. There was no radiological evidence of fracture: osteoarthritis of the spine was present. 3. Evidence is presented that the cord was damaged from behind by the lamina of the vertebra below a tear in the anterior longitudinal ligament


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 4 | Pages 616 - 617
1 Aug 1985
Redfern T Owen R

Traditional posterior approaches to the neck use a vertical craniocaudal incision which often leaves an unsightly scar. An incision along Langer's transverse lines of tension divides only the cross-fibres of the dermis and we have found the results of this approach encouraging: wound healing was uncomplicated and the cosmetic appearance excellent


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 4 | Pages 542 - 543
1 May 2001
Javed A Guichet JM

A fracture of the neck of the radius when the head is not ossified can be difficult to assess and treat. In a four-year-old child we suspected from the radiographs that there was an O’Brien type-III injury after trauma. Partial manual reduction of the non-ossified radial head was completed using the Métaizeau technique of intramedullary Kirschner (K-) wiring aided by intraoperative arthrography. The child had a full range of movement at the elbow and wrist when reviewed 11 weeks after the injury, three weeks after removal of the K-wire. We suggest that intraoperative arthrography is a useful complement to the Métaizeau technique for successful reduction of fractures of the radial neck in the presence of a non-ossified radial head


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 3 | Pages 358 - 361
1 Mar 2006
Prathapkumar KR Garg NK Bruce CE

Several techniques are available for the treatment of displaced fractures of the neck of the radius in children. We report our experience in 14 children treated by indirect reduction and fixation using an elastic stable intramedullary nail. The patients were followed up for a mean of 28 months. One developed asymptomatic avascular necrosis. The rest had excellent results. One had a neuropraxia of the posterior interosseous nerve, which recovered within six weeks. We advocate elastic stable intramedullary nailing for the closed reduction and fixation of these fractures in children


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 4 | Pages 480 - 485
1 Apr 2010
Mannan K Freeman MAR Scott G

The outcome at ten years of 100 Freeman hip stems (Finsbury Orthopaedics, Leatherhead, United Kingdom) retaining the neck with a proximal hydroxyapatite coating in a series of 52 men (six bilateral) and 40 women (two bilateral), has been described previously. None required revision for aseptic loosening. We have extended the follow-up to 20 years with a minimum of 17 years. The mean age of the patients at total hip replacement was 58.9 years (19 to 84). Six patients were lost to follow-up, but were included up to their last clinical review. A total of 22 patients (22 hips) had died, all from causes unrelated to their surgery. There have been 43 re-operations for failure of the acetabular component. However, in 38 of these the stem was not revised since it remained stable and there was no associated osteolysis. Two of the revisions were for damage to the trunnion after fracture of a modular ceramic head, and in another two, removal of the femoral component was because of the preference of the surgeon. In all cases the femoral component was well fixed, but could be extracted at the time of acetabular revision. In one case both components were revised for deep infection. There has been one case of aseptic loosening of the stem which occurred at 14 years. This stem had migrated distally by 7.6 mm in ten years and 8.4 mm at the time of revision at which stage it was found to be rotationally loose. With hindsight this component had been undersized at implantation. The survivorship for the stem at 17 years with aseptic loosening as the endpoint was 98.6% (95% confidence interval 95.9 to 100) when 62 hips were at risk. All remaining stems had a satisfactory clinical and radiological outcome. The Freeman proximally hydroxyapatite-coated femoral component is therefore a dependable implant and its continued use can be recommended


The Journal of Bone & Joint Surgery British Volume
Vol. 55-B, Issue 3 | Pages 647 - 649
1 Aug 1973
Ghawabi MHE

1. Three cases of fracture of the neck of the radius with medial displacement of the head are described. 2. It is proposed that such injuries be classified into two types: 1) displacement of the radial head without dislocation of the elbow; and 2) displacement during posterior dislocation of the elbow


The Journal of Bone & Joint Surgery British Volume
Vol. 51-B, Issue 3 | Pages 508 - 510
1 Aug 1969
Smyth EHJ

A case of injury of the axillary artery complicating a closed fracture of the neck of the humerus in a woman of eighty-six is reported. Spasm was not relieved despite repeated instillation of papaverine. Gangrene developed and amputation above the elbow was required


The Bone & Joint Journal
Vol. 98-B, Issue 4 | Pages 452 - 460
1 Apr 2016
Mahmoud SSS Pearse EO Smith TO Hing CB

Aims

The optimal management of intracapsular fractures of the femoral neck in independently mobile patients remains open to debate. Successful fixation obviates the limitations of arthroplasty for this group of patients. However, with fixation failure rates as high as 30%, the outcome of revision surgery to salvage total hip arthroplasty (THA) must be considered. We carried out a systematic review to compare the outcomes of salvage THA and primary THA for intracapsular fractures of the femoral neck.

Patients and Methods

We performed a Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) compliant systematic review, using the PubMed, EMBASE and Cochrane libraries databases. A meta-analysis was performed where possible, and a narrative synthesis when a meta-analysis was not possible.


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 3 | Pages 406 - 408
1 May 1994
Keller H Rehm K Helling J

We report the treatment of six adult patients with displaced fractures of the radial neck by intramedullary reduction and stabilisation. Nine months after operation all the patients had good joint function, little or no pain, complete healing and no significant periarticular calcification. This simple semi-closed procedure may help to avoid resection of the radial head in some cases


The Journal of Bone & Joint Surgery British Volume
Vol. 44-B, Issue 2 | Pages 349 - 355
1 May 1962
Gibson J Piggott H

1. Correction of hallux valgus by spike osteotomy of the neck of the first metatarsal is described, and the results in eighty-two feet are presented. 2. A high proportion of satisfactory results can be obtained, but great care is needed in both selection and technique. 3. The ideal case is one of moderate deformity, without degenerative arthritis, and with symptoms referable to increased width of the forefoot; the operation should not be performed in cases with obvious degenerative change, nor when metatarsalgia is a prominent symptom. 4. It is important to displace the metatarsal head as far laterally as possible, and vital to avoid dorsal angulation or displacement. 5. It is suggested that enough is now known about the natural evolution of hallux valgus and the results of some operations for prophylactic surgery to be undertaken in carefully selected cases


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 5 | Pages 760 - 764
1 Sep 1992
Steele J Graham H

We made a prospective study of angulated radial neck fractures in children reduced by leverage with a percutaneous Kirschner wire. Of 36 consecutive cases with angulation of more than 30 degrees reduction was successful in 33. We obtained an excellent or good final result in 31 (94%)


The early failure and revision of bimodular primary total hip arthroplasty prostheses requires the identification of the risk factors for material loss and wear at the taper junctions through taper wear analysis. Deviations in taper geometries between revised and pristine modular neck tapers were determined using high resolution tactile measurements. A new algorithm was developed and validated to allow the quantitative analysis of material loss, complementing the standard visual inspection currently used. The algorithm was applied to a sample of 27 retrievals (in situ from 2.9 to 38.1 months) of the withdrawn Rejuvenate modular prosthesis. The mean wear volumes on the flat distal neck piece taper was 3.35 mm. 3. (0.55 to 7.57), mainly occurring in a characteristic pattern in areas with high mechanical loading. Wear volume tended to increase with time to revision (r² = 0.423, p = 0.001). Implant and patient specific data (offset, stem size, patient’s mass, age and body mass index) did not correlate with the amount of material loss observed (p >  0.078). Bilaterally revised implants showed higher amounts of combined total material loss and similar wear patterns on both sides. The consistent wear pattern found in this study has not been reported previously, suggesting that the device design and materials are associated with the failure of this prosthesis. Cite this article: Bone Joint J 2015;97-B:1350–7


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 3 | Pages 381 - 383
1 May 1994
de Laat E Visser C Coene L Pahlplatz P Tavy D

The incidence of nerve injuries in primary shoulder dislocation and humeral neck fracture is uncertain. We made a prospective study of 101 patients, using clinical examination and extensive electrophysiological assessment when there was suspicion of nerve damage. We found electrophysiological evidence of nerve injury in 45%, most involving the axillary, suprascapular, radial and musculocutaneous nerves. There were significantly more nerve injuries in older patients and those with a haematoma. Most patients recovered partially or completely in less than four months, and only eight had persistent motor loss. Early diagnosis and physiotherapy are recommended


The Journal of Bone & Joint Surgery British Volume
Vol. 55-B, Issue 3 | Pages 673 - 673
1 Aug 1973
Wilson RI


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 6 | Pages 933 - 933
1 Aug 2002
Beighton P


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 3 | Pages 346 - 349
1 May 1986
Freeman M


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 3 | Pages 509 - 509
1 May 1993
Kumar V Satku K


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 1 | Pages 104 - 108
1 Jan 1984
Stableforth P

Four-part fractures of the upper end of the humerus are uncommon injuries and there is still dispute about the best form of management. A retrospective study of 32 patients with these injuries has shown that non-operative management is frequently followed by persistent pain, stiffness and dysfunction of the shoulder. A prospective study of 49 patients with this injury presenting at the Bristol Royal Infirmary has shown that reconstruction of the upper end of the humerus with insertion of a Neer prosthesis will usually restore comfort and function. Whichever regimen is employed, disability is prolonged and dedicated physiotherapy is essential in their management.


The Journal of Bone & Joint Surgery British Volume
Vol. 54-B, Issue 4 | Pages 717 - 719
1 Nov 1972
Jeffery CC

The case illustrated substantiates the explanation of the rare epiphysial separation of the head of the radius with 90 degrees backward tilting referred to above as Group 2. It suggests also that the initial fall on the hand may loosen the capital epiphysis.

The undesirability of reducing dislocations of the elbow merely by pulling on the hand of the injured limb is emphasised. The dislocation should be reduced by gentle traction accompanied by pressure with the thumbs on the front of the displaced olecranon.


The Journal of Bone & Joint Surgery British Volume
Vol. 36-B, Issue 3 | Pages 423 - 427
1 Aug 1954
Whiston TB


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 333 - 340
1 Mar 2009
Sariali E Mouttet A Pasquier G Durante E Catone Y

Pre-operative computerised three-dimensional planning was carried out in 223 patients undergoing total hip replacement with a cementless acetabular component and a cementless modular-neck femoral stem. Components were chosen which best restored leg length and femoral offset. The post-operative restoration of the anatomy was assessed by CT and compared with the pre-operative plan.

The component implanted was the same as that planned in 86% of the hips for the acetabular implant, 94% for the stem, and 93% for the neck-shaft angle. The rotational centre of the hip was restored with a mean accuracy of 0.73 mm (sd 3.5) craniocaudally and 1.2 mm (sd 2) laterally. Limb length was restored with a mean accuracy of 0.3 mm (sd 3.3) and femoral offset with a mean accuracy of 0.8 mm (sd 3.1).

This method appears to offer high accuracy in hip reconstruction as the difficulties likely to be encountered when restoring the anatomy can be anticipated and solved pre-operatively by optimising the selection of implants. Modularity of the femoral neck helped to restore the femoral offset and limb length.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 1 | Pages 185 - 185
1 Jan 1998
Laurence M


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 3 | Pages 464 - 464
1 Apr 2004
PRITCHETT JW


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 3 | Pages 419 - 422
1 Apr 2003
Hodgson SA Mawson SJ Stanley D

We undertook a prospective, controlled trial which compared two rehabilitation programmes for 86 patients who sustained two-part fractures of the proximal humerus. Patients were randomised either to receive immediate physiotherapy within one week (group A) or delayed physiotherapy after three weeks of immobilisation in a collar and cuff sling (group B).

At 16 weeks after the fracture, patients in group A had less pain (p < 0.01) and had greater shoulder function (p < 0.001) than those in group B. At 52 weeks, the differences between the groups had reduced. Although group A still had greater shoulder function and less pain, there was no statistical difference when compared with group B. By analysis of the area under the curve, an overall measure up to the 52-week period, group A experienced less pain as measured by the SF36 general health questionnaire and had improved shoulder function.

Our results show that patients with two-part fractures of the proximal humerus who begin immediate physiotherapy, experience less pain. The gains in shoulder function persist at 52 weeks which suggests that patients do not benefit from immobilisation before beginning physiotherapy.


Bone & Joint Research
Vol. 2, Issue 8 | Pages 162 - 168
1 Aug 2013
Chia PH Gualano L Seevanayagam S Weinberg L

Objectives

To determine the morbidity and mortality outcomes of patients presenting with a fractured neck of femur in an Australian context. Peri-operative variables related to unfavourable outcomes were identified to allow planning of intervention strategies for improving peri-operative care.

Methods

We performed a retrospective observational study of 185 consecutive adult patients admitted to an Australian metropolitan teaching hospital with fractured neck of femur between 2009 and 2010. The main outcome measures were 30-day and one-year mortality rates, major complications and factors influencing mortality.


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 3 | Pages 362 - 364
1 May 1992
Herscovici D Fiennes A Allgower M Ruedi T

In ipsilateral mid-clavicular and scapular-neck fractures, the mechanical stability of the suspensory structures is disrupted and muscle forces and the weight of the arm pull the glenoid fragment distally and anteromedially. To prevent late deformity we recommend internal fixation of the fractured clavicle by a plate and screws. We treated seven patients with this unusual injury; all achieved an excellent functional result without deformity.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 6 | Pages 935 - 935
1 Aug 2002
Laurence M


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 2 | Pages 326 - 327
1 Mar 1989
Leung K Tse P


The Journal of Bone & Joint Surgery British Volume
Vol. 51-B, Issue 4 | Pages 707 - 710
1 Nov 1969
Wood SK

Two cases of an unusual injury to the proximal end of the radius in children are reported illustrating a pitfall of closed manipulation. A review of the literature suggests that this injury is comparatively rare and is likely to be followed by permanent restriction of rotation of the forearm.


The Journal of Bone & Joint Surgery British Volume
Vol. 33-B, Issue 4 | Pages 543 - 547
1 Nov 1951
Taylor AR

A case of cervical traumatic paraplegia is described in which there was no evidence of damage to vertebrae, discs or ligaments. Experimental evidence suggests that such injuries may be caused by inward bulging of the ligamentum flavum during hyperextension. The reasons why this inward bulging may occur, despite the elasticity of the ligamentum flavum, are discussed. Treatment of such cases is considered and the importance of avoiding extension emphasised.


Bone & Joint Open
Vol. 4, Issue 10 | Pages 801 - 807
23 Oct 2023
Walter N Szymski D Kurtz SM Lowenberg DW Alt V Lau EC Rupp M

Aims. This work aimed at answering the following research questions: 1) What is the rate of mechanical complications, nonunion and infection for head/neck femoral fractures, intertrochanteric fractures, and subtrochanteric fractures in the elderly USA population? and 2) Which factors influence adverse outcomes?. Methods. Proximal femoral fractures occurred between 1 January 2009 and 31 December 2019 were identified from the Medicare Physician Service Records Data Base. The Kaplan-Meier method with Fine and Gray sub-distribution adaptation was used to determine rates for nonunion, infection, and mechanical complications. Semiparametric Cox regression model was applied incorporating 23 measures as covariates to identify risk factors. Results. Union failure occured in 0.89% (95% confidence interval (CI) 0.83 to 0.95) after head/neck fracturs, in 0.92% (95% CI 0.84 to 1.01) after intertrochanteric fracture and in 1.99% (95% CI 1.69 to 2.33) after subtrochanteric fractures within 24 months. A fracture-related infection was more likely to occur after subtrochanteric fractures than after head/neck fractures (1.64% vs 1.59%, hazard ratio (HR) 1.01 (95% CI 0.87 to 1.17); p < 0.001) as well as after intertrochanteric fractures (1.64% vs 1.13%, HR 1.31 (95% CI 1.12 to 1.52); p < 0.001). Anticoagulant use, cerebrovascular disease, a concomitant fracture, diabetes mellitus, hypertension, obesity, open fracture, and rheumatoid disease was identified as risk factors. Mechanical complications after 24 months were most common after head/neck fractures with 3.52% (95% CI 3.41 to 3.64; currently at risk: 48,282). Conclusion. The determination of complication rates for each fracture type can be useful for informed patient-clinician communication. Risk factors for complications could be identified for distinct proximal femur fractures in elderly patients, which are accessible for therapeutical treatment in the management. Cite this article: Bone Jt Open 2023;4(10):801–807