Advertisement for orthosearch.org.uk
Results 1 - 50 of 118
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 1 | Pages 76 - 81
1 Jan 2005
Pajarinen J Lindahl J Michelsson O Savolainen V Hirvensalo E

We treated 108 patients with a pertrochanteric femoral fracture using either the dynamic hip screw or the proximal femoral nail in this prospective, randomised series. We compared walking ability before fracture, intra-operative variables and return to their residence. Patients treated with the proximal femoral nail (n = 42) had regained their pre-operative walking ability significantly (p = 0.04) more often by the four-month review than those treated with the dynamic hip screw (n = 41). Peri-operative or immediate post-operative measures of outcome did not differ between the groups, with the exception of operation time. The dynamic hip screw allowed a significantly greater compression of the fracture during the four-month follow-up, but consolidation of the fracture was comparable between the two groups. Two major losses of reduction were observed in each group, resulting in a total of four revision operations. Our results suggest that the use of the proximal femoral nail may allow a faster postoperative restoration of walking ability, when compared with the dynamic hip screw


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 616 - 621
1 May 2011
O’Neill F Condon F McGloughlin T Lenehan B Coffey JC Walsh M

We biomechanically investigated whether the standard dynamic hip screw (DHS) or the DHS blade achieves better fixation in bone with regard to resistance to pushout, pullout and torsional stability. The experiments were undertaken in an artificial bone substrate in the form of polyurethane foam blocks with predefined mechanical properties. Pushout tests were also repeated in cadaveric femoral heads. The results showed that the DHS blade outperformed the DHS with regard to the two most important characteristics of implant fixation, namely resistance to pushout and rotational stability. We concluded that the DHS blade was the superior implant in this study


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 4 | Pages 557 - 560
1 Aug 1986
Esser M Kassab J Jones D

In a randomised prospective trial 98 elderly women with trochanteric fractures of the femur were treated with either a 135 degrees Jewett nail-plate or a 135 degrees Dynamic hip screw. The results at six weeks, three months and six months were statistically analysed. There were no significant differences in the two groups with regard to pain, length of hospital stay, morbidity or mortality. Although operative difficulties and open reduction were more common with the Dynamic hip screw, at the end of six months more patients in this group were mobile and there was significant radiological evidence of better compression without loss of fixation


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 5 | Pages 794 - 796
1 Sep 1990
Richards R Evans G Egan J Shearer

We compared, under laboratory conditions, the resistance to cutting out of the AO dynamic hip screw and the Pugh sliding nail. The mean load at cut out, adjusted for bone strength, was 70% greater for the Pugh sliding nail. The reasons for this difference are discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 1073 - 1078
1 Aug 2008
Little NJ Verma V Fernando C Elliott DS Khaleel A

We compared the outcome of patients treated for an intertrochanteric fracture of the femoral neck with a locked, long intramedullary nail with those treated with a dynamic hip screw (DHS) in a prospective randomised study. Each patient who presented with an extra-capsular hip fracture was randomised to operative stabilisation with either a long intramedullary Holland nail or a DHS. We treated 92 patients with a Holland nail and 98 with a DHS. Pre-operative variables included the Mini Mental test score, patient mobility, fracture pattern and American Society of Anesthesiologists grading. Peri-operative variables were anaesthetic time, operating time, radiation time and blood loss. Post-operative variables were time to mobilising with a frame, wound infection, time to discharge, time to fracture union, and mortality. We found no significant difference in the pre-operative variables. The mean anaesthetic and operation times were shorter in the DHS group than in the Holland nail group (29.7 vs 40.4 minutes, p < 0.001; and 40.3 vs 54 minutes, p < 0.001, respectively). There was an increased mean blood loss within the DHS group versus the Holland nail group (160 ml vs 78 ml, respectively, p < 0.001). The mean time to mobilisation with a frame was shorter in the Holland nail group (DHS 4.3 days, Holland nail 3.6 days, p = 0.012). More patients needed a post-operative blood transfusion in the DHS group (23 vs seven, p = 0.003) and the mean radiation time was shorter in this group (DHS 0.9 minutes vs Holland nail 1.56 minutes, p < 0.001). The screw of the DHS cut out in two patients, one of whom underwent revision to a Holland nail. There were no revisions in the Holland nail group. All fractures in both groups were united when followed up after one year. We conclude that the DHS can be implanted more quickly and with less exposure to radiation than the Holland nail. However, the resultant blood loss and need for transfusion is greater. The Holland nail allows patients to mobilise faster and to a greater extent. We have therefore adopted the Holland nail as our preferred method of treating intertrochanteric fractures of the hip


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 5 | Pages 789 - 793
1 Sep 1993
Radford P Needoff M Webb J

We made a randomised prospective comparison of the Dynamic Hip Screw and the Gamma locking nail for the internal fixation of 200 petrochanteric femoral fractures in elderly patients. There was less intraoperative blood loss and a lower rate of wound complications in the patients treated by the Gamma nail. They had, however, a high incidence of femoral shaft fracture which we relate in part to implant design. We do not recommend the use of the Gamma nail for these fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 2 | Pages 330 - 334
1 Mar 1991
Bridle S Patel A Bircher M Calvert P

We have prospectively compared the fixation of 100 intertrochanteric fractures of the proximal femur in elderly patients with random use of either a Dynamic Hip Screw (DHS) or a new intramedullary device, the Gamma nail. We found no difference in operating time, blood loss, wound complications, stay in hospital, place of eventual discharge, or the patients' mobility at final review. There was no difference in failure of proximal fixation: cut-out occurred in three cases with the DHS, and twice with the Gamma nail. However, in four cases fracture of the femur occurred close to the Gamma nail, requiring further major surgery. In the absence of these complications, union was seen by six months in both groups


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 3 | Pages 345 - 351
1 May 1992
Leung K So W Shen W Hui P

The Gamma nail was introduced for the treatment of peritrochanteric fractures with the theoretical advantage of a load-sharing femoral component which could be implanted by a closed procedure. We report a randomised prospective study of 186 fractures treated by either the Gamma nail or a dynamic hip screw. Gamma nails were implanted with significantly shorter screening times, smaller incisions, and less intraoperative bleeding. The Gamma nail group had a shorter convalescence and earlier full weight-bearing, but there was no significant difference in mortality within six months, postoperative mobility, or hip function at review. More intra-operative complications were recorded in the Gamma nail group, mainly due to the mismatching of the femoral component of the nail to the small femurs of Chinese people. Use of a smaller modified nail reduced these complications. We conclude that with careful surgical technique and the modified femoral component, the Gamma nail is an advance in the treatment of peritrochanteric fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 4 | Pages 625 - 625
1 Jul 1992
Parker M


Bone & Joint Research
Vol. 1, Issue 6 | Pages 104 - 110
1 Jun 2012
Swinteck BJ Phan DL Jani J Owen JR Wayne JS Mounasamy V

Objectives. The use of two implants to manage concomitant ipsilateral femoral shaft and proximal femoral fractures has been indicated, but no studies address the relationship of dynamic hip screw (DHS) side plate screws and the intramedullary nail where failure might occur after union. This study compares different implant configurations in order to investigate bridging the gap between the distal DHS and tip of the intramedullary nail. Methods. A total of 29 left synthetic femora were tested in three groups: 1) gapped short nail (GSN); 2) unicortical short nail (USN), differing from GSN by the use of two unicortical bridging screws; and 3) bicortical long nail (BLN), with two angled bicortical and one unicortical bridging screws. With these findings, five matched-pairs of cadaveric femora were tested in two groups: 1) unicortical long nail (ULN), with a longer nail than USN and three bridging unicortical screws; and 2) BLN. Specimens were axially loaded to 22.7 kg (50 lb), and internally rotated 90°/sec until failure. Results. For synthetic femora, a difference was detected between GSN and BLN in energy to failure (p = 0.04) and torque at failure (p = 0.02), but not between USN and other groups for energy to failure (vs GSN, p = 0.71; vs BLN, p = 0.19) and torque at failure (vs GSN, p = 0.55; vs BLN, p = 0.15). For cadaveric femora, ULN and BLN performed similarly because of the improvement provided by the bridging screws. Conclusions. Our study shows that bicortical angled screws in the DHS side plate are superior to no screws at all in this model and loading scenario, and suggests that adding unicortical screws to a gapped construct is probably beneficial


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1134 - 1138
1 Aug 2013
Hsu C Shih C Wang C Huang K

Although the importance of lateral femoral wall integrity is increasingly being recognised in the treatment of intertrochanteric fracture, little attention has been put on the development of a secondary post-operative fracture of the lateral wall. Patients with post-operative fractures of the lateral wall were reported to have high rates of re-operation and complication. To date, no predictors of post-operative lateral wall fracture have been reported. In this study, we investigated the reliability of lateral wall thickness as a predictor of lateral wall fracture after dynamic hip screw (DHS) implantation.

A total of 208 patients with AO/OTA 31-A1 and -A2 classified intertrochanteric fractures who received internal fixation with a DHS between January 2003 and May 2012 were reviewed. There were 103 men and 150 women with a mean age at operation of 78 years (33 to 94). The mean follow-up was 23 months (6 to 83). The right side was affected in 97 patients and the left side in 111. Clinical information including age, gender, side, fracture classification, tip–apex distance, follow-up time, lateral wall thickness and outcome were recorded and used in the statistical analysis.

Fracture classification and lateral wall thickness significantly contributed to post-operative lateral wall fracture (both p < 0.001). The lateral wall thickness threshold value for risk of developing a secondary lateral wall fracture was found to be 20.5 mm.

To our knowledge, this is the first study to investigate the risk factors of post-operative lateral wall fracture in intertrochanteric fracture. We found that lateral wall thickness was a reliable predictor of post-operative lateral wall fracture and conclude that intertrochanteric fractures with a lateral wall thickness < 20.5 mm should not be treated with DHS alone.

Cite this article: Bone Joint J 2013;95-B:1134–8.


Bone & Joint Open
Vol. 4, Issue 8 | Pages 602 - 611
21 Aug 2023
James HK Pattison GTR Griffin J Fisher JD Griffin DR

Aims. To evaluate if, for orthopaedic trainees, additional cadaveric simulation training or standard training alone yields superior radiological and clinical outcomes in patients undergoing dynamic hip screw (DHS) fixation or hemiarthroplasty for hip fracture. Methods. This was a preliminary, pragmatic, multicentre, parallel group randomized controlled trial in nine secondary and tertiary NHS hospitals in England. Researchers were blinded to group allocation. Overall, 40 trainees in the West Midlands were eligible: 33 agreed to take part and were randomized, five withdrew after randomization, 13 were allocated cadaveric training, and 15 were allocated standard training. The intervention was an additional two-day cadaveric simulation course. The control group received standard on-the-job training. Primary outcome was implant position on the postoperative radiograph: tip-apex distance (mm) (DHS) and leg length discrepancy (mm) (hemiarthroplasty). Secondary clinical outcomes were procedure time, length of hospital stay, acute postoperative complication rate, and 12-month mortality. Procedure-specific secondary outcomes were intraoperative radiation dose (for DHS) and postoperative blood transfusion requirement (hemiarthroplasty). Results. Eight female (29%) and 20 male trainees (71%), mean age 29.4 years, performed 317 DHS operations and 243 hemiarthroplasties during ten months of follow-up. Primary analysis was a random effect model with surgeon-level fixed effects of patient condition, patient age, and surgeon experience, with a random intercept for surgeon. Under the intention-to-treat principle, for hemiarthroplasty there was better implant position in favour of cadaveric training, measured by leg length discrepancy ≤ 10 mm (odds ratio (OR) 4.08 (95% confidence interval (CI) 1.17 to 14.22); p = 0.027). There were significantly fewer postoperative blood transfusions required in patients undergoing hemiarthroplasty by cadaveric-trained compared to standard-trained surgeons (OR 6.00 (95% CI 1.83 to 19.69); p = 0.003). For DHS, there was no significant between-group difference in implant position as measured by tip-apex distance ≤ 25 mm (OR 6.47 (95% CI 0.97 to 43.05); p = 0.053). No between-group differences were observed for any secondary clinical outcomes. Conclusion. Trainees randomized to additional cadaveric training performed hip fracture fixation with better implant positioning and fewer postoperative blood transfusions in hemiarthroplasty. This effect, which was previously unknown, may be a consequence of the intervention. Further study is required. Cite this article: Bone Jt Open 2023;4(8):602–611


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 391 - 397
1 Mar 2015
van Embden D Stollenwerck GANL Koster LA Kaptein BL Nelissen RGHH Schipper IB

The aim of this study was to quantify the stability of fracture-implant complex in fractures after fixation. A total of 15 patients with an undisplaced fracture of the femoral neck, treated with either a dynamic hip screw or three cannulated hip screws, and 16 patients with an AO31-A2 trochanteric fracture treated with a dynamic hip screw or a Gamma Nail, were included. Radiostereometric analysis was used at six weeks, four months and 12 months post-operatively to evaluate shortening and rotation. Migration could be assessed in ten patients with a fracture of the femoral neck and seven with a trochanteric fracture. By four months post-operatively, a mean shortening of 5.4 mm (-0.04 to 16.1) had occurred in the fracture of the femoral neck group and 5.0 mm (-0.13 to 12.9) in the trochanteric fracture group. A wide range of rotation occurred in both types of fracture. Right-sided trochanteric fractures seem more rotationally stable than left-sided fractures. This prospective study shows that migration at the fracture site occurs continuously during the first four post-operative months, after which stabilisation occurs. This information may allow the early recognition of patients at risk of failure of fixation. Cite this article: Bone Joint J 2015;97-B:391–7


Bone & Joint Open
Vol. 1, Issue 9 | Pages 594 - 604
24 Sep 2020
James HK Pattison GTR Griffin J Fisher JD Griffin DR

Aims. To develop a core outcome set of measurements from postoperative radiographs that can be used to assess technical skill in performing dynamic hip screw (DHS) and hemiarthroplasty, and to validate these against Van der Vleuten’s criteria for effective assessment. Methods. A Delphi exercise was undertaken at a regional major trauma centre to identify candidate measurement items. The feasibility of taking these measurements was tested by two of the authors (HKJ, GTRP). Validity and reliability were examined using the radiographs of operations performed by orthopaedic resident participants (n = 28) of a multicentre randomized controlled educational trial (ISRCTN20431944). Trainees were divided into novice and intermediate groups, defined as having performed < ten or ≥ ten cases each for DHS and hemiarthroplasty at baseline. The procedure-based assessment (PBA) global rating score was assumed as the gold standard assessment for the purposes of concurrent validity. Intra- and inter-rater reliability testing were performed on a random subset of 25 cases. Results. In total, 327 DHS and 248 hemiarthroplasty procedures were performed by 28 postgraduate year (PGY) 3 to 5 orthopaedic trainees during the 2014 to 2015 surgical training year at nine NHS hospitals in the West Midlands, UK. Overall, 109 PBAs were completed for DHS and 80 for hemiarthroplasty. Expert consensus identified four ‘final product analysis’ (FPA) radiological parameters of technical success for DHS: tip-apex distance (TAD); lag screw position in the femoral head; flushness of the plate against the lateral femoral cortex; and eight-cortex hold of the plate screws. Three parameters were identified for hemiarthroplasty: leg length discrepancy; femoral stem alignment; and femoral offset. Face validity, content validity, and feasibility were excellent. For all measurements, performance was better in the intermediate compared with the novice group, and this was statistically significant for TAD (p < 0.001) and femoral stem alignment (p = 0.023). Concurrent validity was poor when measured against global PBA score. This may be explained by the fact that they are measuring difference facets of competence. Intra-and inter-rater reliability were excellent for TAD, moderate for lag screw position (DHS), and moderate for leg length discrepancy (hemiarthroplasty). Use of a large multicentre dataset suggests good generalizability of the results to other settings. Assessment using FPA was time- and cost-effective compared with PBA. Conclusion. Final product analysis using post-implantation radiographs to measure technical skill in hip fracture surgery is feasible, valid, reliable, and cost-effective. It can complement traditional workplace-based assessment for measuring performance in the real-world operating room . It may have particular utility in competency-based training frameworks and for assessing skill transfer from the simulated to live operating theatre. Cite this article: Bone Joint Open 2020;1-9:594–604


Bone & Joint Open
Vol. 1, Issue 8 | Pages 500 - 507
18 Aug 2020
Cheruvu MS Bhachu DS Mulrain J Resool S Cool P Ford DJ Singh RA

Aims. Our rural orthopaedic service has undergone service restructure during the COVID-19 pandemic in order to sustain hip fracture care. All adult trauma care has been centralised to the Royal Shrewsbury Hospital for assessment and medical input, before transferring those requiring operative intervention to the Robert Jones and Agnes Hunt Orthopaedic Hospital. We aim to review the impact of COVID-19 on hip fracture workload and service changes upon management of hip fractures. Methods. We reviewed our prospectively maintained trust database and National Hip Fracture Database records for the months of March and April between the years 2016 and 2020. Our assessment included fracture pattern (intrascapular vs extracapsular hip fracture), treatment intervention, length of stay and mortality. Results. We treated 288 patients during March and April between 2016 and 2020, with a breakdown of 55, 58, 53, 68, and 54 from 2016 to 2020 respectively. Fracture pattern distribution in the pre-COVID-19 years of 2016 to 2019 was 58% intracapsular and 42% extracapsular. In 2020 (COVID-19 period) the fracture patterns were 65% intracapsular and 35% extracapsular. Our mean length of stay was 13.1 days (SD 8.2) between 2016 to 2019, and 5.0 days (6.3) days in 2020 (p < 0.001). Between 2016 and 2019 we had three deaths in hip fracture patients, and one death in 2020. Hemiarthroplasty and dynamic hip screw fixation have been the mainstay of operative intervention across the five years and this has continued in the COVID-19 period. We have experienced a rise in conservatively managed patients; ten in 2020 compared to 14 over the previous four years. Conclusion. There has not been a reduction in the number of hip fractures during COVID-19 period compared to the same time period over previous years. In our experience, there has been an increase in conservative treatment and decreased length of stay during the COVID -19 period. Cite this article: Bone Joint Open 2020;1-8:500–507


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 162 - 169
1 Feb 2020
Hoellwarth JS Tetsworth K Kendrew J Kang NV van Waes O Al-Maawi Q Roberts C Al Muderis M

Aims. Osseointegrated prosthetic limbs allow better mobility than socket-mounted prosthetics for lower limb amputees. Fractures, however, can occur in the residual limb, but they have rarely been reported. Approximately 2% to 3% of amputees with socket-mounted prostheses may fracture within five years. This is the first study which directly addresses the risks and management of periprosthetic osseointegration fractures in amputees. Methods. A retrospective review identified 518 osseointegration procedures which were undertaken in 458 patients between 2010 and 2018 for whom complete medical records were available. Potential risk factors including time since amputation, age at osseointegration, bone density, weight, uni/bilateral implantation and sex were evaluated with multiple logistic regression. The mechanism of injury, technique and implant that was used for fixation of the fracture, pre-osseointegration and post fracture mobility (assessed using the K-level) and the time that the prosthesis was worn for in hours/day were also assessed. Results. There were 22 periprosthetic fractures; they occurred exclusively in the femur: two in the femoral neck, 14 intertrochanteric and six subtrochanteric, representing 4.2% of 518 osseointegration operations and 6.3% of 347 femoral implants. The vast majority (19/22, 86.4%) occurred within 2 cm of the proximal tip of the implant and after a fall. No fractures occurred spontaneously. Fixation most commonly involved dynamic hip screws (10) and reconstruction plates (9). No osseointegration implants required removal, the K-level was not reduced after fixation of the fracture in any patient, and all retained a K-level of ≥ 2. All fractures united, 21 out of 22 patients (95.5%) wear their osseointegration-mounted prosthetic limb longer daily than when using a socket, with 18 out of 22 (81.8%) reporting using it for ≥ 16 hours daily. Regression analysis identified a 3.89-fold increased risk of fracture for females (p = 0.007) and a 1.02-fold increased risk of fracture per kg above a mean of 80.4 kg (p = 0.046). No increased risk was identified for bilateral implants (p = 0.083), time from amputation to osseointegration (p = 0.974), age at osseointegration (p = 0.331), or bone density (g/cm2, p = 0.560; T-score, p = 0.247; Z-score, p = 0.312). Conclusion. The risks and sequelae of periprosthetic fracture after press-fit osseointegration for amputation should not deter patients or clinicians from considering this procedure. Females and heavier patients are likely to have an increased risk of fracture. Age, years since amputation, and bone density do not appear influential. Cite this article: Bone Joint J 2020;102-B(2):162–169


Bone & Joint Research
Vol. 6, Issue 5 | Pages 270 - 276
1 May 2017
Gosiewski JD Holsgrove TP Gill HS

Objectives. Fractures of the proximal femur are a common clinical problem, and a number of orthopaedic devices are available for the treatment of such fractures. The objective of this study was to assess the rotational stability, a common failure predictor, of three different rotational control design philosophies: a screw, a helical blade and a deployable crucifix. Methods. Devices were compared in terms of the mechanical work (W) required to rotate the implant by 6° in a bone substitute material. The substitute material used was Sawbones polyurethane foam of three different densities (0.08 g/cm. 3. , 0.16 g/cm. 3. and 0.24 g/cm. 3. ). Each torsion test comprised a steady ramp of 1°/minute up to an angular displacement of 10°. Results. The deployable crucifix design (X-Bolt), was more torsionally stable, compared to both the dynamic hip screw (DHS, p = 0.008) and helical blade (DHS Blade, p= 0.008) designs in bone substitute material representative of osteoporotic bone (0.16 g/cm. 3. polyurethane foam). In 0.08 g/cm. 3. density substrate, the crucifix design (X-Bolt) had a higher resistance to torsion than the screw (DHS, p = 0.008). There were no significant differences (p = 0.101) between the implants in 0.24 g/cm. 3. density bone substitute. Conclusions. Our findings indicate that the clinical standard proximal fracture fixator design, the screw (DHS), was the least effective at resisting torsional load, and a novel crucifix design (X-Bolt), was the most effective design in resisting torsional load in bone substitute material with density representative of osteoporotic bone. At other densities the torsional stability was also higher for the X-Bolt, although not consistently significant by statistical analysis. Cite this article: J. D. Gosiewski, T. P. Holsgrove, H. S. Gill. The efficacy of rotational control designs in promoting torsional stability of hip fracture fixation. Bone Joint Res 2017;6:270–276. DOI: 10.1302/2046-3758.65.BJR-2017-0287.R1


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1198 - 1201
1 Sep 2014
Magu NK Singla R Rohilla R Gogna P Mukhopadhyay R Singh A

We report the outcome of 39 patients who underwent a modified Pauwels’ intertrochanteric osteotomy for nonunion of a femoral neck fracture following failed osteosynthesis. There were 31 men and eight women with a mean age of 47.2 years (34 to 59). By Pauwels’ classification, there were 11 Type II fractures and 28 Type III fractures. The mean follow-up was 7.9 years (2 to 19). In the 11 patients whose initial treatment had been osteotomy, union was achieved in nine (81.8%). In 28 patients whose initial treatment had been with a lag screw or a dynamic hip screw, union was achieved in 27 (96.4%). Limb lengths were equalised in 14 of 16 patients (87.5%) with pre-operative shortening. The mean neck-shaft angle improved significantly from 100.5° (80° to 120°) to 131.6° (120° to 155°) (p = 0.004). The mean modified Harris hip score was 85.6 points (70 to 97) and the mean modified Merle d’Aubigné score was 14.3 (11 to 18). Good to excellent functional outcomes were achieved in 32 patients (88.8%). A modified Pauwels’ intertrochanteric osteotomy is a reliable method of treating ununited fractures of the femoral neck following failed osteosynthesis: coxa vara and shortening can also simultaneously be addressed. Cite this article: Bone Joint J 2014;96-B:1198–1201


Bone & Joint Research
Vol. 1, Issue 4 | Pages 50 - 55
1 Apr 2012
O’Neill F Condon F McGloughlin T Lenehan B Coffey C Walsh M

Introduction. The objective of this study was to determine if a synthetic bone substitute would provide results similar to bone from osteoporotic femoral heads during in vitro testing with orthopaedic implants. If the synthetic material could produce results similar to those of the osteoporotic bone, it could reduce or eliminate the need for testing of implants on bone. Methods. Pushout studies were performed with the dynamic hip screw (DHS) and the DHS Blade in both cadaveric femoral heads and artificial bone substitutes in the form of polyurethane foam blocks of different density. The pushout studies were performed as a means of comparing the force displacement curves produced by each implant within each material. Results. The results demonstrated that test material with a density of 0.16 g/cm. 3. (block A) produced qualitatively similar force displacement curves for the DHS and qualitatively and quantitatively similar force displacement curves for the DHS Blade, whereas the test material with a density of 0.08 g/cm. 3. (block B) did not produce results that were predictive of those recorded within the osteoporotic cadaveric femoral heads. Conclusion. This study demonstrates that synthetic material with a density of 0.16 g/cm. 3. can provide a good substitute for cadaveric osteoporotic femoral heads in the testing of implants. However we do recognise that no synthetic material can be considered as a definitive substitute for bone, therefore studies performed with artificial bone substrates may need to be validated by further testing with a small bone sample in order to produce conclusive results


Bone & Joint Open
Vol. 3, Issue 11 | Pages 907 - 912
23 Nov 2022
Hurley RJ McCabe FJ Turley L Maguire D Lucey J Hurson CJ

Aims

The use of fluoroscopy in orthopaedic surgery creates risk of radiation exposure to surgeons. Appropriate personal protective equipment (PPE) can help mitigate this. The primary aim of this study was to assess if current radiation protection in orthopaedic trauma is safe. The secondary aims were to describe normative data of radiation exposure during common orthopaedic procedures, evaluate ways to improve any deficits in protection, and validate the use of electronic personal dosimeters (EPDs) in assessing radiation dose in orthopaedic surgery.

Methods

Radiation exposure to surgeons during common orthopaedic trauma operations was prospectively assessed using EPDs and thermoluminescent dosimeters (TLDs). Normative data for each operation type were calculated and compared to recommended guidelines.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 6 | Pages 815 - 818
1 Aug 2001
Alonso JA Shaw DL Maxwell A McGill GP Hart GC

We measured the scattered radiation received by theatre staff, using high-sensitivity electronic personal dosimeters, during fixation of extracapsular fractures of the neck of the femur by dynamic hip screw. The dose received was correlated with that received by the patient, and the distance from the source of radiation. A scintillation detector and a water-filled model were used to define a map of the dose rate of scattered radiation in a standard operating theatre during surgery. Beyond two metres from the source of radiation, the scattered dose received was consistently low, while within the operating distance that received by staff was significant for both lateral and posteroanterior (PA) projections. The routine use of lead aprons outside the 2 m zone may be unnecessary. Within that zone it is recommended that lead aprons be worn and that thyroid shields are available for the surgeon and nursing assistants


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 5 | Pages 701 - 712
1 Sep 1994
Case C Langkamer V James C Palmer M Kemp A Heap P Solomon L

In a post-mortem study, we compared subjects with metal implants with and without visible wear with an age-matched control group to determine the extent and effects of dissemination of wear debris. In subjects with stainless-steel and cobalt-chrome prostheses metal was found in local and distant lymph nodes, bone marrow, liver and spleen. The levels were highest in subjects with loose, worn joint prostheses and the main source of the debris was the matt coating. Metal levels were also raised in subjects with implants without visible wear and, to a less extent, in those with dynamic hip screws. Necrosis of lymph nodes was seen in those cases with the most wear, and potential damage to more distant organs such as the bone marrow, liver and spleen in the long term cannot be discounted. The consequences for the immune system and the role of metal dissemination in the possible induction of neoplasia are discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 5 | Pages 789 - 792
1 Sep 1994
Gargan M Gundle R Simpson A

Osteotomy has been used in the treatment of unstable intertrochanteric hip fractures in an attempt to increase the stability of the fracture fragments. We have assessed this stability in a randomised prospective trial on 100 consecutive patients, all having fixation by an AO dynamic hip screw, comparing anatomical reduction with two types of osteotomy. The groups were similar in terms of age, gender, mental test score, and fracture configuration. There were more failures of fixation in the osteotomy groups, and the operations took longer. We found no clear benefit from osteotomy and therefore recommend anatomical reduction and fixation by a sliding hip screw in most cases. Rarely, a fracture configuration which does not allow load-sharing between the fracture fragments and the device may benefit from an osteotomy or the use of an alternative implant


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 3 | Pages 340 - 344
1 May 1992
Halder S

The Gamma nail was designed to treat unstable intertrochanteric and subtrochanteric fractures. The device was developed after cadaver studies and has been used clinically since February 1985 in a total of 421 patients. The results in 123 patients treated by the third version of this design are reported. The Gamma nail transmits weight closer to the calcar than does the dynamic hip screw and it has greater mechanical strength. A semi-closed operative technique is used, with an average duration of operation of 35 minutes and little blood loss. Distal locking screws can be used to maintain rotational stability, and can be inserted without the use of an image intensifier. Results showed satisfactory fracture union with little loss of position, even in comminuted fractures. Operative complications were few, but included fractures of the base of the greater trochanter. The most important postoperative complication, seen in one case, was fracture of the shaft of the femur at the distal end of the nail, but this healed well after re-nailing


Bone & Joint Open
Vol. 4, Issue 5 | Pages 329 - 337
8 May 2023
Khan AQ Chowdhry M Sherwani MKA McPherson EJ

Aims

Total hip arthroplasty (THA) is considered the preferred treatment for displaced proximal femoral neck fractures. However, in many countries this option is economically unviable. To improve outcomes in financially disadvantaged populations, we studied the technique of concomitant valgus hip osteotomy and operative fixation (VOOF). This prospective serial study compares two treatment groups: VOOF versus operative fixation alone with cannulated compression screws (CCSs).

Methods

In the first series, 98 hip fixation procedures were performed using CCS. After fluoroscopic reduction of the fracture, three CCSs were placed. In the second series, 105 VOOF procedures were performed using a closing wedge intertrochanteric osteotomy with a compression lag screw and lateral femoral plate. The alignment goal was to create a modified Pauwel’s fracture angle of 30°. After fluoroscopic reduction of fracture, lag screw was placed to achieve the calculated correction angle, followed by inter-trochanteric osteotomy and placement of barrel plate. Patients were followed for a minimum of two years.


Bone & Joint Open
Vol. 5, Issue 6 | Pages 457 - 463
2 Jun 2024
Coviello M Abate A Maccagnano G Ippolito F Nappi V Abbaticchio AM Caiaffa E Caiaffa V

Aims

Proximal femur fractures treatment can involve anterograde nailing with a single or double cephalic screw. An undesirable failure for this fixation is screw cut-out. In a single-screw nail, a tip-apex distance (TAD) greater than 25 mm has been associated with an increased risk of cut-out. The aim of the study was to examine the role of TAD as a risk factor in a cephalic double-screw nail.

Methods

A retrospective study was conducted on 112 patients treated for intertrochanteric femur fracture with a double proximal screw nail (Endovis BA2; EBA2) from January to September 2021. The analyzed variables were age, sex, BMI, comorbidities, fracture type, side, time of surgery, quality of reduction, pre-existing therapy with bisphosphonate for osteoporosis, screw placement in two different views, and TAD. The last follow-up was at 12 months. Logistic regression was used to study the potential factors of screw cut-out, and receiver operating characteristic curve to identify the threshold value.


The Bone & Joint Journal
Vol. 104-B, Issue 12 | Pages 1362 - 1368
1 Dec 2022
Rashid F Mahmood A Hawkes DH Harrison WJ

Aims

Prior to the availability of vaccines, mortality for hip fracture patients with concomitant COVID-19 infection was three times higher than pre-pandemic rates. The primary aim of this study was to determine the 30-day mortality rate of hip fracture patients in the post-vaccine era.

Methods

A multicentre observational study was carried out at 19 NHS Trusts in England. The study period for the data collection was 1 February 2021 until 28 February 2022, with mortality tracing until 28 March 2022. Data collection included demographic details, data points to calculate the Nottingham Hip Fracture Score, COVID-19 status, 30-day mortality, and vaccination status.


Bone & Joint 360
Vol. 11, Issue 5 | Pages 34 - 36
1 Oct 2022


The Bone & Joint Journal
Vol. 104-B, Issue 12 | Pages 1369 - 1378
1 Dec 2022
van Rijckevorsel VAJIM de Jong L Verhofstad MHJ Roukema GR

Aims

Factors associated with high mortality rates in geriatric hip fracture patients are frequently unmodifiable. Time to surgery, however, might be a modifiable factor of interest to optimize clinical outcomes after hip fracture surgery. This study aims to determine the influence of postponement of surgery due to non-medical reasons on clinical outcomes in acute hip fracture surgery.

Methods

This observational cohort study enrolled consecutively admitted patients with a proximal femoral fracture, for which surgery was performed between 1 January 2018 and 11 January 2021 in two level II trauma teaching hospitals. Patients with medical indications to postpone surgery were excluded. A total of 1,803 patients were included, of whom 1,428 had surgery < 24 hours and 375 had surgery ≥ 24 hours after admission.


Bone & Joint Open
Vol. 3, Issue 9 | Pages 710 - 715
5 Sep 2022
Khan SK Tyas B Shenfine A Jameson SS Inman DS Muller SD Reed MR

Aims

Despite multiple trials and case series on hip hemiarthroplasty designs, guidance is still lacking on which implant to use. One particularly deficient area is long-term outcomes. We present over 1,000 consecutive cemented Thompson’s hemiarthroplasties over a ten-year period, recording all accessible patient and implant outcomes.

Methods

Patient identifiers for a consecutive cohort treated between 1 January 2003 and 31 December 2011 were linked to radiographs, surgical notes, clinic letters, and mortality data from a national dataset. This allowed charting of their postoperative course, complications, readmissions, returns to theatre, revisions, and deaths. We also identified all postoperative attendances at the Emergency and Outpatient Departments, and recorded any subsequent skeletal injuries.


Bone & Joint Open
Vol. 3, Issue 3 | Pages 182 - 188
1 Mar 2022
Boktor J Badurudeen A Rijab Agha M Lewis PM Roberts G Hills R Johansen A White S

Aims

In UK there are around 76,000 hip fractures occur each year 10% to 15% of which are undisplaced intracapsular. There is considerable debate whether internal fixation is the most appropriate treatment for undisplaced fractures in older patients. This study describes cannulated hip screws survivorship analysis for patients aged ≥ 60 years with undisplaced intra-capsular fractures.

Methods

This was a retrospective cohort study of consecutive patients aged ≥ 60 years who had cannulated screws fixation for Garden I and II fractures in a teaching hospital between March 2013 and March 2016. The primary outcome was further same-side hip surgery. Descriptive statistics were used and Kaplan-Meier estimates calculated for implant survival.


Bone & Joint 360
Vol. 11, Issue 3 | Pages 46 - 47
1 Jun 2022
Das A


Bone & Joint Research
Vol. 11, Issue 2 | Pages 102 - 111
1 Feb 2022
Jung C Cha Y Yoon HS Park CH Yoo J Kim J Jeon Y

Aims

In this study, we aimed to explore surgical variations in the Femoral Neck System (FNS) used for stable fixation of Pauwels type III femoral neck fractures.

Methods

Finite element models were established with surgical variations in the distance between the implant tip and subchondral bone, the gap between the plate and lateral femoral cortex, and inferior implant positioning. The models were subjected to physiological load.


Bone & Joint Open
Vol. 2, Issue 8 | Pages 661 - 670
19 Aug 2021
Ajayi B Trompeter AJ Umarji S Saha P Arnander M Lui DF

Aims

The new COVID-19 variant was reported by the authorities of the UK to the World Health Organization (WHO) on 14 December 2020. We aim to describe the clinical characteristics and nosocomial infection rates in major trauma and orthopaedic patients comparing the first and second wave of COVID-19 infection.

Methods

A retrospective analysis of a prospectively collected trauma database was reviewed at a level 1 major trauma centre from 1 December 2020 to 18 February 2021 looking at demographics, clinical characteristics, and nosocomial infections and compared to our previously published first wave data (26 January 2020 to 14 April 2020).


Bone & Joint Open
Vol. 2, Issue 12 | Pages 1017 - 1026
1 Dec 2021
Sadiq S Lipski C Hanif U Arshad F Chaudary M Chaudhry F

Aims

This study assessed the impact of COVID-19 on hip and distal femur fracture patient outcomes across three successive UK lockdown periods over one year.

Methods

A single-centre retrospective cohort study was performed at an acute NHS Trust. Hip and distal femur fracture patients admitted within the first month from each of the three starting dates of each national lockdown were included and compared to a control group in March 2019. Data were collected as per the best practice tariff outcomes including additional outcomes as required. Data collection included COVID-19 status, time to theatre, 30-day mortality, presence of acute kidney injury (AKI) and pneumonia, and do not attempt cardiopulmonary resuscitation (DNACPR) status. Data were analyzed using an independent-samples t-test or chi-squared test with Fisher’s exact test where applicable. A p-value of < 0.05 was considered statistically significant.


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 782 - 787
3 Apr 2021
Mahmood A Rashid F Limb R Cash T Nagy MT Zreik N Reddy G Jaly I As-Sultany M Chan YTC Wilson G Harrison WJ

Aims

Despite the COVID-19 pandemic, incidence of hip fracture has not changed. Evidence has shown increased mortality rates associated with COVID-19 infection. However, little is known about the outcomes of COVID-19 negative patients in a pandemic environment. In addition, the impact of vitamin D levels on mortality in COVID-19 hip fracture patients has yet to be determined.

Methods

This multicentre observational study included 1,633 patients who sustained a hip fracture across nine hospital trusts in North West England. Data were collected for three months from March 2020 and for the same period in 2019. Patients were matched by Nottingham Hip Fracture Score (NHFS), hospital, and fracture type. We looked at the mortality outcomes of COVID-19 positive and COVID-19 negative patients sustaining a hip fracture. We also looked to see if vitamin D levels had an impact on mortality.


Bone & Joint 360
Vol. 10, Issue 3 | Pages 38 - 39
1 Jun 2021
Das A


Bone & Joint Open
Vol. 1, Issue 7 | Pages 392 - 397
13 Jul 2020
Karayiannis PN Roberts V Cassidy R Mayne AIW McAuley D Milligan DJ Diamond O

Aims

Now that we are in the deceleration phase of the COVID-19 pandemic, the focus has shifted to how to safely reinstate elective operating. Regional and speciality specific data is important to guide this decision-making process. This study aimed to review 30-day mortality for all patients undergoing orthopaedic surgery during the peak of the pandemic within our region.

Methods

This multicentre study reviewed data on all patients undergoing trauma and orthopaedic surgery in a region from 18 March 2020 to 27 April 2020. Information was collated from regional databases. Patients were COVID-19-positive if they had positive laboratory testing and/or imaging consistent with the infection. 30-day mortality was assessed for all patients. Secondly, 30-day mortality in fracture neck of femur patients was compared to the same time period in 2019.


Bone & Joint Open
Vol. 1, Issue 10 | Pages 645 - 652
19 Oct 2020
Sheridan GA Hughes AJ Quinlan JF Sheehan E O'Byrne JM

Aims

We aim to objectively assess the impact of COVID-19 on mean total operative cases for all indicative procedures (as outlined by the Joint Committee on Surgical Training (JCST)) experienced by orthopaedic trainees in the deanery of the Republic of Ireland. Subjective experiences were reported for each trainee using questionnaires.

Methods

During the first four weeks of the nationwide lockdown due to COVID-19, the objective impact of the pandemic on each trainee’s surgical caseload exposure was assessed using data from individual trainee logbook profiles in the deanery of the Republic of Ireland. Independent predictor variables included the trainee grade (ST 3 to 8), the individual trainee, the unit that the logbook was reported from, and the year in which the logbook was recorded. We used the analysis of variance (ANOVA) test to assess for any statistically significant predictor variables. The subjective experience of each trainee was captured using an electronic questionnaire.


Bone & Joint 360
Vol. 10, Issue 2 | Pages 21 - 23
1 Apr 2021


Bone & Joint Open
Vol. 2, Issue 5 | Pages 293 - 300
3 May 2021
Lewis PM Khan FJ Feathers JR Lewis MH Morris KH Waddell JP

Aims

“Get It Right First Time” (GIRFT) and NHS England’s Best Practice Tariff (BPT) have published directives advising that patients over the ages of 65 (GIRFT) and 69 years (BPT) receiving total hip arthroplasty (THA) should receive cemented implants and have brought in financial penalties if this policy is not observed. Despite this, worldwide, uncemented component use has increased, a situation described as a ‘paradox’. GIRFT and BPT do, however, acknowledge more data are required to support this edict with current policies based on the National Joint Registry survivorship and implant costs.

Methods

This study compares THA outcomes for over 1,000 uncemented Corail/Pinnacle constructs used in all age groups/patient frailty, under one surgeon, with identical pre- and postoperative pathways over a nine-year period with mean follow-up of five years and two months (range: nine months to nine years and nine months). Implant information, survivorship, and regular postoperative Oxford Hip Scores (OHS) were collected and two comparisons undertaken: a comparison of those aged over 65 years with those 65 and under and a second comparison of those aged 70 years and over with those aged under 70.


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1136 - 1145
14 Sep 2020
Kayani B Onochie E Patil V Begum F Cuthbert R Ferguson D Bhamra JS Sharma A Bates P Haddad FS

Aims

During the COVID-19 pandemic, many patients continue to require urgent surgery for hip fractures. However, the impact of COVID-19 on perioperative outcomes in these high-risk patients remains unknown. The objectives of this study were to establish the effects of COVID-19 on perioperative morbidity and mortality, and determine any risk factors for increased mortality in patients with COVID-19 undergoing hip fracture surgery.

Methods

This multicentre cohort study included 340 COVID-19-negative patients versus 82 COVID-19-positive patients undergoing surgical treatment for hip fractures across nine NHS hospitals in Greater London, UK. Patients in both treatment groups were comparable for age, sex, body mass index, fracture configuration, and type of surgery performed. Predefined perioperative outcomes were recorded within a 30-day postoperative period. Univariate and multivariate analysis were used to identify risk factors associated with increased risk of mortality.


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 442 - 448
1 Mar 2021
Nikolaou VS Masouros P Floros T Chronopoulos E Skertsou M Babis GC

Aims

The aim of this study was to investigate the hypothesis that a single dose of tranexamic acid (TXA) would reduce blood loss and transfusion rates in elderly patients undergoing surgery for a subcapital or intertrochanteric (IT) fracture of the hip.

Methods

In this single-centre, randomized controlled trial, elderly patients undergoing surgery for a hip fracture, either hemiarthroplasty for a subcapital fracture or intramedullary nailing for an IT fracture, were screened for inclusion. Patients were randomly allocated to a study group using a sealed envelope. The TXA group consisted of 77 patients, (35 with a subcapital fracture and 42 with an IT fracture), and the control group consisted of 88 patients (29 with a subcapital fracture and 59 with an IT fracture). One dose of 15 mg/kg of intravenous (IV) TXA diluted in 100 ml normal saline (NS,) or one dose of IV placebo 100 ml NS were administered before the incision was made. The haemoglobin (Hb) concentration was measured before surgery and daily until the fourth postoperative day. The primary outcomes were the total blood loss and the rate of transfusion from the time of surgery to the fourth postoperative day.


Bone & Joint Open
Vol. 1, Issue 6 | Pages 229 - 235
9 Jun 2020
Lazizi M Marusza CJ Sexton SA Middleton RG

Aims

Elective surgery has been severely curtailed as a result of the COVID-19 pandemic. There is little evidence to guide surgeons in assessing what processes should be put in place to restart elective surgery safely in a time of endemic COVID-19 in the community.

Methods

We used data from a stand-alone hospital admitting and operating on 91 trauma patients. All patients were screened on admission and 100% of patients have been followed-up after discharge to assess outcome.


Bone & Joint 360
Vol. 9, Issue 6 | Pages 15 - 18
1 Dec 2020


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 170 - 177
4 Jan 2021
Craxford S Marson BA Oderuth E Nightingale J Agrawal Y Ollivere B

Aims

Infection after surgery increases treatment costs and is associated with increased mortality. Hip fracture patients have historically had high rates of methicillin-resistant Staphylococcus aureus (MRSA) colonization and surgical site infection (SSI). This paper reports the impact of routine MRSA screening and the “cleanyourhands” campaign on rates of MRSA SSI and patient outcome.

Methods

A total of 13,503 patients who presented with a hip fracture over 17 years formed the study population. Multivariable logistic regression was performed to determine risk factors for MRSA and SSI. Autoregressive integrated moving average (ARIMA) modelling adjusted for temporal trends in rates of MRSA. Kaplan-Meier estimators were generated to assess for changes in mortality.


Bone & Joint 360
Vol. 9, Issue 2 | Pages 33 - 37
1 Apr 2020


Bone & Joint Open
Vol. 1, Issue 11 | Pages 669 - 675
1 Nov 2020
Ward AE Tadross D Wells F Majkowski L Naveed U Jeyapalan R Partridge DG Madan S Blundell CM

Aims

Within the UK, around 70,000 patients suffer neck of femur (NOF) fractures annually. Patients presenting with this injury are often frail, leading to increased morbidity and a 30-day mortality rate of 6.1%. COVID-19 infection has a broad spectrum of clinical presentations with the elderly, and those with pre-existing comorbidities are at a higher risk of severe respiratory compromise and death. Further increased risk has been observed in the postoperative period. The aim of this study was to assess the impact of COVID-19 infection on the complication and mortality rates of NOF fracture patients.

Methods

All NOF fracture patients presenting between March 2020 and May 2020 were included. Patients were divided into two subgroup: those with or without clinical and/or laboratory diagnosis of COVID-19. Data were collected on patient demographics, pattern of injury, complications, length of stay, and mortality.


Bone & Joint Open
Vol. 1, Issue 11 | Pages 697 - 705
10 Nov 2020
Rasidovic D Ahmed I Thomas C Kimani PK Wall P Mangat K

Aims

There are reports of a marked increase in perioperative mortality in patients admitted to hospital with a fractured hip during the COVID-19 pandemic in the UK, USA, Spain, and Italy. Our study aims to describe the risk of mortality among patients with a fractured neck of femur in England during the early stages of the COVID-19 pandemic.

Methods

We completed a multicentre cohort study across ten hospitals in England. Data were collected from 1 March 2020 to 6 April 2020, during which period the World Health Organization (WHO) declared COVID-19 to be a pandemic. Patients ≥ 60 years of age admitted with hip fracture and a minimum follow-up of 30 days were included for analysis. Primary outcome of interest was mortality at 30 days post-surgery or postadmission in nonoperative patients. Secondary outcomes included length of hospital stay and discharge destination.


Bone & Joint Open
Vol. 1, Issue 9 | Pages 568 - 575
18 Sep 2020
Dayananda KSS Mercer ST Agarwal R Yasin T Trickett RW

Aims

COVID-19 necessitated abrupt changes in trauma service delivery. We compare the demographics and outcomes of patients treated during lockdown to a matched period from 2019. Findings have important implications for service development.

Methods

A split-site service was introduced, with a COVID-19 free site treating the majority of trauma patients. Polytrauma, spinal, and paediatric trauma patients, plus COVID-19 confirmed or suspicious cases, were managed at another site. Prospective data on all trauma patients undergoing surgery at either site between 16 March 2020 and 31 May 2020 was collated and compared with retrospective review of the same period in 2019. Patient demographics, injury, surgical details, length of stay (LOS), COVID-19 status, and outcome were compared.