Aims. This study aimed to analyze the accuracy and errors associated with 3D-printed, patient-specific resection guides (3DP-PSRGs) used for
Objectives. We evaluated the accuracy of augmented reality (AR)-based navigation assistance through simulation of
Aims. Iliac wing (Type I) and iliosacral (Type I/IV) pelvic resections for a primary
Aims. We present a retrospective review of patients treated with extracorporeally
irradiated allografts for primary and secondary
Amputation was once widely practised for primary
Needle biopsy is an established technique for the histological diagnosis of
Between 1988 and 2006, 18 patients had a custom-made endoprosthetic replacement of the distal humerus for
Endoprosthetic replacement of the distal tibia and ankle joint for a primary
We report our experience with a new technique for cryosurgical ablation of
Aims. Resection of the proximal humerus for the primary malignant bone
tumour sometimes requires en bloc resection of the
deltoid. However, there is no information in the literature which
helps a surgeon decide whether to preserve the deltoid or not. The
aim of this study was to determine whether retaining the deltoid
at the time of resection would increase the rate of local recurrence.
We also sought to identify the variables that persuade expert surgeons
to choose a deltoid sparing rather than deltoid resecting procedure. Patients and Methods. We reviewed 45 patients who had undergone resection of a primary
malignant tumour of the proximal humerus. There were 29 in the deltoid
sparing group and 16 in the deltoid resecting group. Imaging studies
were reviewed to assess tumour extension and soft-tissue involvement.
The presence of a fat rim separating the tumour from the deltoid
on MRI was particularly noted. The cumulative probability of local
recurrence was calculated in a competing risk scenario. Results. There was no significant difference (adjusted p = 0.89) in the
cumulative probability of local recurrence between the deltoid sparing
(7%, 95% confidence interval (CI) 1 to 20) and the deltoid resecting
group (26%, 95% CI 8 to 50). Patients were more likely to be selected
for a deltoid sparing procedure if they presented with a small tumour
(p = 0.0064) with less bone involvement (p = 0.032) and a continuous
fat rim on MRI (p = 0.002) and if the axillary nerve could be identified
(p = 0.037). Conclusion. A deltoid sparing procedure can provide good local control after
resection of the proximal humerus for a primary malignant
Custom-made intercalary endoprostheses may be used for the reconstruction of diaphyseal defects following the resection of
We reviewed 25 patients who had undergone resection of a primary bone sarcoma which extended to within 5 cm of the knee with reconstruction by a combination of a free vascularised fibular graft and a massive allograft bone shell. The distal femur was affected in four patients and the proximal tibia in 21. Their mean age at the time of operation was 19.7 years (5 to 52) and the mean follow-up period 140 months (28 to 213). Three vascularised transfers failed. The mean time to union of the fibula was 5.6 months (3 to 10) and of the allograft 19.6 months (10 to 34). Full weight-bearing was allowed at a mean of 21.4 months (14 to 36). The mean functional score at final follow-up was 27.4 (18 to 30) using a modfied 30-point Musculoskeletal Tumour Society rating system. The overall limb-salvage rate was 88%. The results of our study suggest that the combined use of a vascularised fibular graft and allograft is of value as a limb-salvage procedure for intercalary reconstruction after resection of
We reviewed the results of 51 patients with benign
The standard of surgical treatment for lower limb neoplasms had been characterized by highly interventional techniques, leading to severe kinetic impairment of the patients and incidences of phantom pain. Rotationplasty had arisen as a potent limb salvage treatment option for young cancer patients with lower limb bone tumours, but its impact on the gait through comparative studies still remains unclear several years after the introduction of the procedure. The aim of this study is to assess the effect of rotationplasty on gait parameters measured by gait analysis compared to healthy individuals. The MEDLINE, Scopus, and Cochrane databases were systematically searched without time restriction until 10 January 2022 for eligible studies. Gait parameters measured by gait analysis were the outcomes of interest.Aims
Methods
We undertook a retrospective review of 33 patients who underwent total femoral endoprosthetic replacement as limb salvage following excision of a malignant
Endoprosthetic reconstruction following distal femur tumour resection has been widely advocated. In this paper, we present the design of an uncemented endoprosthesis system featuring a short, curved stem, with the goal of enhancing long-term survivorship and functional outcomes. This study involved patients who underwent implantation of an uncemented distal femoral endoprosthesis with a short and curved stem between 2014 and 2019. Functional outcomes were assessed using the 1993 version of the Musculoskeletal Tumour Society (MSTS-93) score. Additionally, we quantified five types of complications and assessed osseointegration radiologically. The survivorship of the endoprosthesis was evaluated according to two endpoints. A total of 134 patients with a median age of 26 years (IQR 16 to 41) were included in our study. The median follow-up time was 61 months (IQR 56 to 76), and the median functional MSTS-93 was 83% (IQR 73 to 91) postoperatively.Aims
Methods
We retrospectively evaluated 18 patients with a mean age of 37.3 years (14 to 72) who had undergone pelvic reconstruction stabilised with a non-vascularised fibular graft after resection of a primary
Osteoarticular reconstruction of the distal femur in childhood has the advantage of preserving the tibial physis. However, due to the small size of the distal femur, matching the host bone with an osteoarticular allograft is challenging. In this study, we compared the outcomes and complications of a resurfaced allograft-prosthesis composite (rAPC) with those of an osteoarticular allograft to reconstruct the distal femur in children. A retrospective analysis of 33 skeletally immature children with a malignant tumour of the distal femur, who underwent resection and reconstruction with a rAPC (n = 15) or osteoarticular allograft (n = 18), was conducted. The median age of the patients was ten years (interquartile range (IQR) 9 to 11) in the osteoarticular allograft group and nine years (IQR 8 to 10) in the rAPC group (p = 0.781). The median follow-up of the patients was seven years (IQR 4 to 8) in the osteoarticular allograft group and six years (IQR 3 to 7) in the rAPC group (p = 0.483). Limb function was evaluated using the Musculoskeletal Tumor Society (MSTS) score.Aims
Methods
In skeletally immature patients, resection of
bone tumours and reconstruction of the lower limb often results
in leg-length discrepancy. The Stanmore non-invasive extendible
endoprosthesis, which uses electromagnetic induction, allows post-operative
lengthening without anaesthesia. Between 2002 and 2009, 55 children
with a mean age of 11.4 years (5 to 16) underwent reconstruction
with this prosthesis; ten patients (18.2%) died of disseminated
disease and one child underwent amputation due to infection. We
reviewed 44 patients after a mean follow-up of 41.2 months (22 to
104). The mean Musculoskeletal Tumor Society score was 24.7 (8 to
30) and the Toronto Extremity Salvage score was 92.3% (55.2% to
99.0%). There was no local recurrence of tumour. Complications developed
in 16 patients (29.1%) and ten (18.2%) underwent revision. The mean length gained per patient was 38.6 mm (3.5 to 161.5),
requiring a mean of 11.3 extensions (1 to 40), and ten component
exchanges were performed in nine patients (16.4%) after attaining
the maximum lengthening capacity of the implant. There were 11 patients
(20%) who were skeletally mature at follow-up, ten of whom had equal
leg lengths and nine had a full range of movement of the hip and
knee. This is the largest reported series using non-invasive extendible
endoprostheses after excision of primary
We treated 75 patients with benign
Aims. Pelvic reconstruction after the resection of a tumour around
the acetabulum is a challenging procedure due to the complex anatomy
and biomechanics. Several pelvic endoprostheses have been introduced,
but the rates of complication remain high. Our aim was to review
the use of a stemmed acetabular pedestal cup in the management of
these patients. Patients and Methods. The study involved 48 patients who underwent periacetabular reconstruction
using a stemmed pedestal cup (Schoellner cup; Zimmer Biomet Inc.,
Warsaw, Indiana) between 2000 and 2013. The indications for treatment included
a primary
Segmental resection of malignant bone disease in the femoral diaphysis with subsequent limb reconstruction is a major undertaking. This is a retrospective review of 23 patients who had undergone limb salvage by endoprosthetic replacement of the femoral diaphysis for a primary
Endoprosthetic reconstruction following resection of 31 tumours of the proximal femur in 30 patients was performed using a Wagner SL femoral revision stem. The mean follow-up was 25.6 months (0.6 to 130.0). Of the 28 patients with a metastasis, 27 died within a mean follow-up period of 18.1 months (0.6 to 56.3) after the operation, and the remaining patient was excluded from the study 44.4 months post-operatively when the stem was removed. The two patients with primary
The use of allografts for the treatment of
Chondrosarcoma is the second most common primary sarcoma of bone: conventional chondrosarcoma accounts for 85% of all cases. Conventional chondrosarcoma may be central or peripheral. Most studies group central and peripheral chondrosarcomas together, although there is growing evidence that their clinical behaviour and prognosis differ. The aims of this study were to analyze any differences in characteristics between central and peripheral chondrosarcomas and to investigate the incidence and role of different syndromes. Data from two international tertiary referral sarcoma centres between January 1995 and December 2018 were retrospectively reviewed. The study population consisted of 714 patients with surgically treated conventional chondrosarcoma of the pelvis and limbs.Aims
Methods
This paper describes the preliminary results of a proximal tibial endoprosthesis which spares the knee joint and enables retention of the natural articulation by replacing part of the tibial metaphysis and diaphysis. In eight patients who had a primary malignant
We report two patients with malignant
Limb salvage is now customary in the treatment of primary
An unusual
We carried out extensible endoprosthetic replacement of the proximal or total humerus in 18 children aged between six and 12 years, after resection of primary
We report 60 benign
The purpose of this study was to describe the effect of histological
grade on disease-specific survival in patients with chondrosarcoma. A total of 343 patients with a chondrosarcoma were included.
The histological grade was assessed on the initial biopsy and on
the resection specimen. Where the histology showed a mixed grade,
the highest grade was taken as the definitive grade. When only small
focal areas showed higher grade, the final grade was considered
as both.Aims
Patients and Methods
We analysed the gait characteristics of 15 patients with prosthetic reconstruction of the proximal femur after resection of a malignant
Acridine orange (AO) demonstrates several biological activities. When exposed to low doses of X-ray radiation, AO increases the production of reactive radicals (radiodynamic therapy (AO-RDT)). We elucidated the efficacy of AO-RDT in breast and prostate cancer cell lines, which are likely to develop bone metastases. We used the mouse osteosarcoma cell line LM8, the human breast cancer cell line MDA-MB-231, and the human prostate cancer cell line PC-3. Cultured cells were exposed to AO and radiation at various concentrations followed by various doses of irradiation. The cell viability was then measured. In vivo, each cell was inoculated subcutaneously into the backs of mice. In the AO-RDT group, AO (1.0 μg) was locally administered subcutaneously around the tumour followed by 5 Gy of irradiation. In the radiation group, 5 Gy of irradiation alone was administered after macroscopic tumour formation. The mice were killed on the 14th day after treatment. The change in tumour volume by AO-RDT was primarily evaluated.Aims
Methods
We have studied 35 patients with infected reconstructions after segmental resection for
The purpose of this retrospective study was to differentiate
between the MRI features of normal post-operative change and those
of residual or recurrent disease after intralesional treatment of
an atypical cartilage tumour (ACT)/grade I chondrosarcoma. We reviewed the case notes, radiology and histology of 75 patients,
who had been treated for an ACT/grade I chondrosarcoma by curettage,
phenolisation and bone allografting between 1994 and 2005. The first
post-operative Gd-enhanced MRI scan was carried out within one year
of surgery. Patients had a minimum of two scans and a mean follow-up
of 72 months (13 to 169). Further surgery was undertaken in cases
of suspected recurrence.Aims
Patients and Methods
We assessed the intermediate functional results of eight patients after wide resection of the proximal humerus for malignant
Resection of the distal femur or proximal tibia en bloc has been performed on twenty-six patients with primary
There is insufficient evidence to support bony reconstruction of the pubis after a type III internal hemipelvectomy (resection of all or part of the pubis). In this study, we compared surgical complications, postoperative pain, and functional outcome in a series of patients who had undergone a type III internal hemipelvectomy with or without bony reconstruction. In a retrospective cohort study, 32 patients who had undergone a type III hemipelvectomy with or without allograft reconstruction (n = 15 and n = 17, respectively) were reviewed. The mean follow-up was 6.7 years (SD 3.8) for patients in the reconstruction group and 6.1 years (SD 4.0) for patients in the non-reconstruction group. Functional outcome was evaluated using the Musculoskeletal Tumor Society (MSTS) scoring system and the level of postoperative pain with a visual analogue scale (VAS).Aim
Methods
The consensus is that bipolar hemiarthroplasty (BHA) in allograft-prosthesis composite (APC) reconstruction of the proximal femur following primary tumour resection provides more stability than total hip arthroplasty (THA). However, no comparative study has been performed. In this study, we have compared the outcome and complication rates of these two methods. In a retrospective study, 57 patients who underwent APC reconstruction of proximal femur following the primary tumour resection, either using BHA (29) or THA (28), were included. Functional outcome was assessed using the Musculoskeletal Tumour Society (MSTS) scoring system and Harris Hip Score (HHS). Postoperative complications of the two techniques were also compared.Aims
Methods
Vascularised fibular grafts (VFGs ) are a valuable
surgical technique in limb salvage after resection of a tumour.
The primary objective of this multicentre study was to assess the
risk factors for failure and complications for using a VFG after
resection of a tumour. The study involved 74 consecutive patients (45 men and 29 women
with mean age of 23 years (1 to 64) from four tertiary centres for
orthopaedic oncology who underwent reconstruction using a VFG after
resection of a tumour between 1996 and 2011. There were 52 primary
and 22 secondary reconstructions. The mean follow-up was 77 months
(10 to 195). In all, 69 patients (93%) had successful limb salvage; all of
these united and 65 (88%) showed hypertrophy of the graft. The mean
time to union differed between those involving the upper (28 weeks;
12 to 96) and lower limbs (44 weeks; 12 to 250). Fracture occurred
in 11 (15%), and nonunion in 14 (19%) patients. In 35 patients (47%) at least one complication arose, with a
greater proportion in lower limb reconstructions, non-bridging osteosynthesis,
and in children. These complications resulted in revision surgery
in 26 patients (35%). VFG is a successful and durable technique for reconstruction
of a defect in bone after resection of a tumour, but is accompanied
by a significant risk of complications, that often require revision
surgery. Union was not markedly influenced by the need for chemo-
or radiotherapy, but should not be expected during chemotherapy.
Therefore, restricted weight-bearing within this period is advocated. Cite this article:
We investigated whether improvements in design have altered the outcome for patients undergoing endoprosthetic replacement of the distal femur after resection of a tumour. Survival of the implant and ‘servicing’ procedures have been documented using a prospective database, review of the design of the implant and case records. In total, 335 patients underwent a distal femoral replacement, 162 having a fixed-hinge design and 173 a rotating-hinge. The median age of the patients was 24 years (interquartile range 17 to 48). A total of 192 patients remained alive with a mean follow-up of 12 years (5 to 30). The risk of revision for any reason was 17% at five years, 33% at ten years and 58% at 20 years. Aseptic loosening was the main reason for revision of the fixed-hinge knees while infection and fracture of the stem were the most common for the rotating-hinge implant. The risk of revision for aseptic loosening was 35% at ten years with the fixed-hinge knee, which has, however, been replaced by the rotating-hinge knee with a hydroxyapatite collar. The overall risk of revision for any reason fell by 52% when the rotating-hinge implant was used. Improvements in the design of distal femoral endoprostheses have significantly decreased the need for revision operations, but infection remains a serious problem. We believe that a cemented, rotating-hinge prosthesis with a hydroxyapatite collar offers the best chance of long-term survival of the prosthesis.
We present a retrospective study of patients suffering from a variety of benign tumours in whom external fixators were used to treat deformity and limb-length discrepancy, and for the reconstruction of bone defects. A total of 43 limbs in 31 patients (12 male and 19 female) with a mean age of 14 years (2 to 54) were treated. The diagnosis was Ollier’s disease in 12 limbs, fibrous dysplasia in 11, osteochondroma in eight, giant cell tumour in five, osteofibrous dysplasia in five and non-ossifying fibroma in two. The lesions were treated in the tibia in 19 limbs, in the femur in 16, and in the forearm in eight. The Ilizarov frame was used in 25 limbs, the Taylor Spatial Frame in seven, the Orthofix fixator in six, the Monotube in four and the Heidelberg fixator in one. The mean follow-up was 72 months (22 to 221). The mean external fixation period was 168 days (71 to 352). The mean external fixation index was 42 days/cm (22.2 to 102.0) in the 22 patients who required limb lengthening. The mean correction angle for those with angular deformity was 23° (7° to 45°). At final follow-up all patients had returned to normal activities. Four patients required a second operation for recurrent deformity of further limb lengthening. Local recurrence occurred in one patient, requiring further surgery.
Rarely, the extent of a malignant bone tumour
may necessitate resection of the complete humerus to achieve adequate
oncological clearance. We present our experience with reconstruction
in such cases using a total humeral endoprosthesis (THER) in 20
patients (12 male and eight female) with a mean age of 22 years
(6 to 59). We assessed the complications, the oncological and functional
outcomes and implant survival. Surgery was performed between June
2001 and October 2009. The diagnosis included osteosarcoma in nine,
Ewing’s sarcoma in eight and chondrosarcoma in three. One patient
was lost to follow-up. The mean follow-up was 41 months (10 to 120)
for all patients and 56 months (25 to 120) in survivors. There were
five local recurrences (26.3%) and 11 patients were alive at time
of last follow-up, with overall survival for all patients being
52% (95% confidence interval (CI) 23.8 to 74) at five years. The
mean Musculoskeletal Tumor Society score for the survivors was 22
(73%; 16 to 23). The implant survival was 95% (95% CI 69.5 to 99.3)
at five years. The use of a THER in the treatment of malignant tumours of bone
is oncologically safe; it gives consistent and predictable results
with low rates of complication.
We reviewed 29 patients who had undergone intercalary resection for malignant tumours. Of these, 14 had received segmental allograft reconstruction and 15 extracorporeally-irradiated autograft. At a mean follow-up of 71 months (24 to 132), 20 were free from disease, five had died and four were alive with pulmonary metastases. Two patients, one with an allograft and one with an irradiated autograft, had a local recurrence. Reconstruction with extracorporeally-irradiated autograft has a significantly lower rate of nonunion (7% Extracorporeally-irradiated autograft could be an acceptable alternative for reconstruction after intercalary resection, especially in countries where it is difficult to obtain allografts.
We investigated the functional outcome in patients
who underwent reverse shoulder replacement (RSR) after removal of
a tumour of the proximal humerus. A total of 16 patients (ten women
and six men) underwent this procedure between 1998 and 2011 in our
hospital. Five patients died and one was lost to follow-up. Ten
patients were available for review at a mean follow-up of 46 months
(12 to 136). Eight patients had a primary and two patients a secondary
bone tumour. At final follow up the mean range of active movement was: abduction
78° (30° to 150°); flexion 98° (45° to 180°); external rotation
32° (10° to 60°); internal rotation 51° (10° to 80°). The mean Musculoskeletal
Tumor Society score was 77% (60% to 90%) and the mean Toronto Extremity
Salvage Score was 70% (30% to 91%). Two patients had a superficial
infection and one had a deep infection and underwent a two-stage
revision procedure. In two patients there was loosening of the RSR;
one dislocated twice. All patients had some degree of atrophy or
pseudo-atrophy of the deltoid muscle. Use of a RSR in patients with a tumour of the proximal humerus
gives acceptable results. Cite this article:
We have investigated whether improvements in design have altered the outcome for patients undergoing endoprosthetic replacement of the proximal tibia following resection of a tumour. Survival of the implant and ‘servicing’ procedures have been documented using a prospective database. A total of 194 patients underwent a proximal tibial replacement, with 95 having a fixed-hinge design and 99 a rotating-hinge with a hydroxyapatite collar; their median age was 21.5 years (10 to 74). At a mean follow-up of 14.7 years (5 to 29), 115 patients remain alive. The risk of revision for any reason in the fixed-hinge group was 32% at five years, 61% at ten years and 75% at 15 and 20 years, and in the rotating-hinge group 12% at five years, 25% at ten years and 30% at 15 years. Aseptic loosening was the most common reason for revision in the fixed-hinge knees, fracture of the implant in the early design of rotating hinges and infection in the current version. The risk of revision for aseptic loosening in the fixed-hinge knees was 46% at ten years. This was reduced to 3% in the rotating-hinge knee with a hydroxyapatite collar. The cemented, rotating hinge design currently offers the best chance of long-term survival of the prosthesis.
We determined the efficacy of a devitalised autograft
(n = 13) and allograft (n = 16) cortical strut bone graft combined
with long-stem endoprosthetic reconstruction in the treatment of
massive tumours of the lower limb. A total of 29 patients (18 men:11
women, mean age 20.1 years (12 to 45) with a ratio of length of
resection to that of the whole prosthesis of >
50% were treated
between May 2003 and May 2012. The mean follow-up was 47 months
(15 to 132). The stem of the prosthesis was introduced through bone
graft struts filled with cement, then cemented into the residual
bone. Bone healing was achieved in 23 patients (86%). The mean Musculoskeletal
Tumour Society functional score was 85% (57 to 97). The five-year
survival rate of the endoprostheses was 81% (95% confidence intervals
67.3 to 92.3). The mean length of devitalised autografts and allografts
was 8.6 cm (5 to 15), which increased the ratio of the the length
of the stem of the prosthesis to that of the whole length of the
prosthesis from a theoretical 35% to an actual 55%. Cortical strut bone grafting and long-stem endoprosthetic reconstruction
is an option for treating massive segmental defects following resection
of a tumour in the lower limb. Patients can regain good function
with a low incidence of aseptic loosening. The strut graft and the
residual bone together serve as a satisfactory bony environment
for a revision prosthesis, if required, once union is achieved. Cite this article: