Advertisement for orthosearch.org.uk
Results 1 - 20 of 321
Results per page:
The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1314 - 1320
1 Dec 2023
Broida SE Sullivan MH Barlow JD Morrey M Scorianz M Wagner ER Sanchez-Sotelo J Rose PS Houdek MT

Aims. The scapula is a rare site for a primary bone tumour. Only a small number of series have studied patient outcomes after treatment. Previous studies have shown a high rate of recurrence, with functional outcomes determined by the preservation of the glenohumeral joint and deltoid. The purpose of the current study was to report the outcome of patients who had undergone tumour resection that included the scapula. Methods. We reviewed 61 patients (37 male, 24 female; mean age 42 years (SD 19)) who had undergone resection of the scapula. The most common resection was type 2 (n = 34) according to the Tikhoff-Linberg classification, or type S1A (n = 35) on the Enneking classification. Results. The ten-year disease-specific survival was 76%. High tumour grade (hazard ratio (HR) 4.27; p = 0.016) and a total resection of the scapula (HR 3.84; p = 0.015) were associated with worse survival. The ten-year metastasis-free and local recurrence-free survivals were 82% and 86%, respectively. Total scapular resection (HR 6.29; p = 0.004) was associated with metastatic disease and positive margins were associated with local recurrence (HR 12.86; p = 0.001). At final follow-up, the mean shoulder forward elevation and external rotation were 79° (SD 62°) and 27° (SD 25°), respectively. The most recent functional outcomes evaluated included the mean Musculoskeletal Tumor Society Score (76% (SD 17%)), the American Shoulder and Elbow Score (73% (SD 20%)), and the Simple Shoulder Test (7 (SD 3)). Preservation of the glenoid (p = 0.001) and scapular spine (p < 0.001) improved clinical outcomes; interestingly, preservation of the scapular spine without the glenoid improved outcomes (p < 0.001) compared to preservation of the glenoid alone (p = 0.05). Conclusion. Resection of the scapula is a major undertaking with an oncological outcome related to tumour grade, and a functional outcome associated with the status of the scapular spine and glenoid. Positive resection margins are associated with local recurrence. Cite this article: Bone Joint J 2023;105-B(12):1314–1320


The Bone & Joint Journal
Vol. 102-B, Issue 11 | Pages 1438 - 1445
1 Nov 2020
Jang YH Lee JH Kim SH

Aims. Scapular notching is thought to have an adverse effect on the outcome of reverse total shoulder arthroplasty (RTSA). However, the matter is still controversial. The aim of this study was to determine the clinical impact of scapular notching on outcomes after RTSA. Methods. Three electronic databases (PubMed, Cochrane Database, and EMBASE) were searched for studies which evaluated the influence of scapular notching on clinical outcome after RTSA. The quality of each study was assessed. Functional outcome scores (the Constant-Murley scores (CMS), and the American Shoulder and Elbow Surgeons (ASES) scores), and postoperative range of movement (forward flexion (FF), abduction, and external rotation (ER)) were extracted and subjected to meta-analysis. Effect sizes were expressed as weighted mean differences (WMD). Results. In all, 11 studies (two level III and nine level IV) were included in the meta-analysis. All analyzed variables indicated that scapular notching has a negative effect on the outcome of RTSA . Statistical significance was found for the CMS (WMD –3.11; 95% confidence interval (CI) –4.98 to –1.23), the ASES score (WMD –6.50; 95% CI –10.80 to –2.19), FF (WMD –6.3°; 95% CI –9.9° to –2.6°), and abduction (WMD –9.4°; 95% CI –17.8° to –1.0°), but not for ER (WMD –0.6°; 95% CI –3.7° to 2.5°). Conclusion. The current literature suggests that patients with scapular notching after RTSA have significantly worse results when evaluated by the CMS, ASES score, and range of movement in flexion and abduction. Cite this article: Bone Joint J 2020;102-B(11):1438–1445


Bone & Joint 360
Vol. 13, Issue 2 | Pages 38 - 41
1 Apr 2024

The April 2024 Oncology Roundup. 360. looks at: Midterm outcomes of total hip arthroplasty after internal hemipelvectomy and iliofemoral arthrodesis; Intraosseous conventional central chondrosarcoma does not metastasize irrespective of grade in pelvis, scapula, and in long bone locations; Oncological and functional outcomes after resection of malignant tumours of the scapula; Reconstruction following oncological iliosacral resection – a comparison of techniques; Does primary tumour resection improve survival for patients with sarcomas of pelvic bones, sacrum, and coccyx who have metastasis at diagnosis?; Older patients with Ewing’s sarcoma: an analysis of the National Cancer Database; Diagnostic challenges in low-grade central osteosarcoma; Effect of radiotherapy on local recurrence, distant metastasis, and overall survival in 1,200 limb soft-tissue sarcoma patients: a retrospective analysis using inverse probability of treatment weighting-adjusted models


The Bone & Joint Journal
Vol. 98-B, Issue 11 | Pages 1510 - 1516
1 Nov 2016
Suter T Henninger HB Zhang Y Wylie JD Tashjian RZ

Aims. The aim of this study was to analyse the effect of altered viewing perspectives on the measurement of the glenopolar angle (GPA) and the differences between these measurements made on 3D CT reconstructions and anteroposterior (AP) scapular view radiographs. . Materials and Methods. The influence of the viewing perspective on the GPA was assessed, as were the differences in the measurements of the GPA between 3D CT reconstructions and AP scapular view radiographs in 68 cadaveric scapulae. Results. The median GPA in 3D reconstructions and AP scapular views were 42.7° (95% confidence intervals (CI), 42.0° to 43.5°) and 41.3° (95% CI 40.4° to 42.0°) respectively (p < 0.001). All but five of 20 malpositions demonstrated a significant difference in GPA compared with the respective AP scapular view (p ≤ 0.005). The GPA was most susceptible to malposition in retroversion/anteversion. Inter- and intra-observer reliability for all measurements of the GPA was excellent for 3D CT reconstructions (intraclass correlation (ICC) 0.93 (95% CI 0.87 to 0.96) and 0.94 (95% CI 0.89 to 0.97), respectively) and higher than on AP scapular radiographs (p < 0.001). The intra- and inter-observer reliability was excellent in AP scapular views and malpositions in extension/flexion (ICC ≥ 0.84) but tended to decrease with increasing viewing angle in retroversion/anteversion. Conclusion. These data suggest that 3D reconstructions are more reproducible than AP scapular radiographs in the assessment of the GPA and should be used to compare data in different studies, to predict outcome, define malunion, and act as an indication for surgery in patients with a scapular fracture. Cite this article: Bone Joint J 2016;98-B:1510–16


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1284 - 1292
1 Nov 2024
Moroder P Poltaretskyi S Raiss P Denard PJ Werner BC Erickson BJ Griffin JW Metcalfe N Siegert P

Aims. The objective of this study was to compare simulated range of motion (ROM) for reverse total shoulder arthroplasty (rTSA) with and without adjustment for scapulothoracic orientation in a global reference system. We hypothesized that values for simulated ROM in preoperative planning software with and without adjustment for scapulothoracic orientation would be significantly different. Methods. A statistical shape model of the entire humerus and scapula was fitted into ten shoulder CT scans randomly selected from 162 patients who underwent rTSA. Six shoulder surgeons independently planned a rTSA in each model using prototype development software with the ability to adjust for scapulothoracic orientation, the starting position of the humerus, as well as kinematic planes in a global reference system simulating previously described posture types A, B, and C. ROM with and without posture adjustment was calculated and compared in all movement planes. Results. All movement planes showed significant differences when comparing protocols with and without adjustment for posture. The largest mean difference was seen in external rotation, being 62° (SD 16°) without adjustment compared to 25° (SD 9°) with posture adjustment (p < 0.001), with the highest mean difference being 49° (SD 15°) in type C. Mean extension was 57° (SD 18°) without adjustment versus 24° (SD 11°) with adjustment (p < 0.001) and the highest mean difference of 47° (SD 18°) in type C. Mean abducted internal rotation was 69° (SD 11°) without adjustment versus 31° (SD 6°) with posture adjustment (p < 0.001), showing the highest mean difference of 51° (SD 11°) in type C. Conclusion. The present study demonstrates that accounting for scapulothoracic orientation has a significant impact on simulated ROM for rTSA in all motion planes, specifically rendering vastly lower values for external rotation, extension, and high internal rotation. The substantial differences observed in this study warrant a critical re-evaluation of all previously published studies that examined component choice and placement for optimized ROM in rTSA using conventional preoperative planning software. Cite this article: Bone Joint J 2024;106-B(11):1284–1292


The Bone & Joint Journal
Vol. 100-B, Issue 9 | Pages 1182 - 1186
1 Sep 2018
Werner BS Chaoui J Walch G

Aims. Scapular notching is a frequently observed radiographic phenomenon in reverse shoulder arthroplasty (RSA), signifying impingement of components. The purposes of this study were to evaluate the effect of glenoid component size and glenosphere type on impingement-free range of movement (ROM) for extension and internal and external rotation in a virtual RSA model, and to determine the optimal configuration to reduce the incidence of friction-type scapular notching. Materials and Methods. Preoperative CT scans obtained in 21 patients (three male, 18 female) with primary osteoarthritis were analyzed using modelling software. Two concurrent factors were tested for impingement-free ROM and translation of the centre of rotation: glenosphere diameter (36 mm vs 39 mm) and type (centred, 2 mm inferior eccentric offset, 10° inferior tilt). Results. Glenosphere size was most predictive of increased extension and external rotation, whereas lateralization of the centre of rotation was the most predictive factor for internal rotation. A larger diameter of glenosphere combined with a 10° tilted configuration demonstrated superior values for extension and external rotation, whereas the eccentric component improved internal rotation by a mean 8.9° (standard deviation 2.7°) compared with a standard concentric glenosphere. Conclusion. Glenosphere configuration can be modified to increase range of movement in RSA. Friction-type scapular notching was most effectively reduced by use of a large-diameter glenosphere with 10° inferior tilt. Cite this article: Bone Joint J 2018;100-B:1182–6


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 5 | Pages 619 - 626
1 May 2009
Herrera DA Anavian J Tarkin IS Armitage BA Schroder LK Cole PA

Between 1998 and 2007, 22 patients with fractures of the scapula had operative treatment more than three weeks after injury. The indications for operation included displaced intra-articular fractures, medialisation of the glenohumeral joint, angular deformity, or displaced double lesions of the superior shoulder suspensory complex. Radiological and functional outcomes were obtained for 16 of 22 patients. Disabilities of the Arm, Shoulder, Hand (DASH) and Short form-36 scores were collected for 14 patients who were operated on after March 2002. The mean delay from injury to surgery was 30 days (21 to 57). The mean follow-up was for 27 months (12 to 72). At the last review the mean DASH score was 14 (0 to 41). Of the 16 patients with follow-up, 13 returned to their previous employment and recreational activities without restrictions. No wound complications, infection or nonunion occurred. Malunion of the scapula can be prevented by surgical treatment of fractures in patients with delayed presentation. Surgery is safe, effective, and gives acceptable functional results


The Journal of Bone & Joint Surgery British Volume
Vol. 55-B, Issue 2 | Pages 345 - 349
1 May 1973
Parsons TA

1. Five cases are reported in which snapping of the scapula was caused by subscapular exostosis. In the four cases in which the exostosis was excised, symptoms were relieved without loss of scapular movement. 2. Antero-posterior views of the scapula do not always show the exostosis, and oblique views are recommended. 3. Winging of the scapula may be caused by a subscapular mass, with a neurologically intact subscapularis muscle. 4. Apart from subscapular exostoses, snapping of the scapula may be caused by exostoses or abnormal angles on the ribs, by Luschka's tubercle, or by an abnormal forward curve of the superior angle of the scapula


The Journal of Bone & Joint Surgery British Volume
Vol. 62-B, Issue 4 | Pages 486 - 490
1 Nov 1980
Wilkinson J Campbell D

The features of congenital elevation of the scapula are described for a group of 16 children. Fibrous bands which tether the scapula and limit its movements were discovered in most children. Vertical displacement osteotomy of the medial border of the scapula and division of the fibrous attachments have provided a reliable and safe treatment for 12 children during the past 10 years


The Journal of Bone & Joint Surgery British Volume
Vol. 54-B, Issue 3 | Pages 395 - 408
1 Aug 1972
Cavendish ME

1. One hundred cases of congenital elevation of the scapula are reviewed; thirty-four were treated by operation. 2. A method of grading of appearance is suggested to assist in selecting cases for operation. 3. In very mild cases operation does not confer worthwhile benefit. 4. Very severely affected patients cannot be made to look normal. 5. The appearance often deteriorates during a period of rapid growth of the neck, making continued observation and reassessment essential. 6. The primary aim of treatment is to improve appearance; improvement in function is uncertain. 7. Excision of the supero-medial part of the scapula, and of the omo-vertebral bone when present, is recommended in most cases requiring operation. It is safe and simple, with little risk of loss of function and with simple after-treatment


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 986 - 989
1 Jul 2005
McMurtry I Bennet GC Bradish C

We report 12 consecutive cases of vertical scapular osteotomy to correct Sprengel’s deformity, performed during a 16-year period, with a mean follow-up of 10.4 years. The mean increase in abduction of the shoulder was 53°. The cosmetic appearance improved by a mean of 1.5 levels on the Cavendish scale. Neither function nor cosmesis deteriorated with time. We recommend the procedure for correction of moderate deformities with a functional deficit


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1253 - 1259
1 Sep 2012
Sewell MD Higgs DS Al-Hadithy N Falworth M Bayley I Lambert SM

Scapulothoracic fusion (STF) for painful winging of the scapula in neuromuscular disorders can provide effective pain relief and functional improvement, but there is little information comparing outcomes between patients with dystrophic and non-dystrophic conditions. We performed a retrospective review of 42 STFs in 34 patients with dystrophic and non-dystrophic conditions using a multifilament trans-scapular, subcostal cable technique supported by a dorsal one-third semi-tubular plate. There were 16 males and 18 females with a mean age of 30 years (15 to 75) and a mean follow-up of 5.0 years (2.0 to 10.6). The mean Oxford shoulder score improved from 20 (4 to 39) to 31 (4 to 48). Patients with non-dystrophic conditions had lower overall functional scores but achieved greater improvements following STF. The mean active forward elevation increased from 59° (20° to 90°) to 97° (30° to 150°), and abduction from 51° (10° to 90°) to 83° (30° to 130°) with a greater range of movement achieved in the dystrophic group. Revision fusion for nonunion was undertaken in five patients at a mean time of 17 months (7 to 31) and two required revision for fracture. There were three pneumothoraces, two rib fractures, three pleural effusions and six nonunions. The main risk factors for nonunion were smoking, age and previous shoulder girdle surgery. STF is a salvage procedure that can provide good patient satisfaction in 82% of patients with both dystrophic and non-dystrophic pathologies, but there was a relatively high failure rate (26%) when poor outcomes were analysed. Overall function was better in patients with dystrophic conditions which correlated with better range of movement; however, patients with non-dystrophic conditions achieved greater functional improvement


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 1 | Pages 108 - 110
1 Jan 1987
Iceton J Harris W

We report the transfer of the sternal part of the pectoralis major to the lower pole of the scapula in 15 patients with winged scapula. At follow-up after 1 to 16 years nine had a satisfactory result and were gainfully employed, though in four of these re-operation had been necessary. Two patients had fair results; the transplant functioned, but they had limited voluntary control. Four were failures: two had had paralysis of other shoulder girdle muscles in addition to the serratus anterior. The indications for the operation are discussed


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1199 - 1202
1 Nov 2024
Watts AC Tennent TD Haddad FS


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 5 | Pages 598 - 605
1 Nov 1983
Grogan D Stanley E Bobechko W

At The Hospital for Sick Children in Toronto, 21 undescended scapulae were corrected by the Woodward procedure in 20 patients over the past 18 years. The average age at operation was six years six months. The average follow-up period after operation was 8 years 9 months. Fifteen patients were girls and five were boys. All the patients had other associated abnormalities. Only one patient had a concomitant clavicular osteotomy. The average increase in glenohumeral abduction was 37 degrees. The average scapular lowering was two centimetres. Excellent or good cosmetic results were obtained in 80 per cent of patients. Ninety-three per cent of patients expressed satisfaction with the operative results. Complications were few. The Woodward procedure is a safe and relatively straightforward surgical means to effect a good cosmetic and functional improvement in a patient with a congenital undescended scapula. We do not recommend clavicular osteotomy as a routine, but it may be added to gain more correction with less risk of neurovascular compression


The Journal of Bone & Joint Surgery British Volume
Vol. 47-B, Issue 2 | Pages 300 - 303
1 May 1965
Burwell HN

1. Resection of the shoulder for a malignant tumour involving the scapula which was too extensive for treatment by excision of the bone is described. 2. The procedure is suggested as an alternative to forequarter amputation in suitable instances


The Journal of Bone & Joint Surgery British Volume
Vol. 61-B, Issue 1 | Pages 59 - 63
1 Feb 1979
Banniza von Bazan U

Of forty-six patients with congenital elevation of the scapula, diastematomyelia was confirmed in four and was probably present in five others. Possible reasons for the previously unsuspected association are presented


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 6 | Pages 813 - 817
1 Aug 2000
Atasoy E Majd M

We have used a modified technique in five patients to correct winging of the scapula caused by injury to the brachial plexus or the long thoracic nerve during transaxillary resection of the first rib. The procedure stabilises the scapulothoracic articulation by using strips of autogenous fascia lata wrapped around the 4th, 6th and 7th ribs at least two, and preferably three, times. The mean age of the patients at the time of operation was 38 years (26 to 47) and the mean follow-up six years and four months (three years and three months to 11 years). Satisfactory stability was achieved in all patients with considerable improvement in shoulder function. There were no complications


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1114 - 1120
1 Aug 2013
Wijdicks CA Anavian J Hill BW Armitage BM Vang S Cole PA

The glenopolar angle assesses the rotational alignment of the glenoid and may provide prognostic information and aid the management of scapula fractures. We have analysed the effect of the anteroposterior (AP) shoulder radiograph rotational offset on the glenopolar angle in a laboratory setting and used this to assess the accuracy of shoulder imaging employed in routine clinical practice. Fluoroscopic imaging was performed on 25 non-paired scapulae tagged with 2 mm steel spheres to determine the orientation of true AP views. The glenopolar angle was measured on all the bony specimens rotated at 10° increments. The mean glenopolar angle measured on the bone specimens in rotations between 0° and 20° and thereafter was found to be significantly different (p < 0.001). We also obtained the AP radiographs of the uninjured shoulder of 30 patients treated for fractures at our centre and found that none fitted the criteria of a true AP shoulder radiograph. The mean angular offset from the true AP view was 38° (10° to 65°) for this cohort. Radiological AP shoulder views may not fully project the normal anatomy of the scapular body and the measured glenopolar angle. The absence of a true AP view may compromise the clinical management of a scapular fracture.

Cite this article: Bone Joint J 2013;95-B:1114–20.


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 530 - 535
1 Apr 2013
Roche CP Marczuk Y Wright TW Flurin P Grey S Jones R Routman HD Gilot G Zuckerman JD

This study provides recommendations on the position of the implant in reverse shoulder replacement in order to minimise scapular notching and osteophyte formation. Radiographs from 151 patients who underwent primary reverse shoulder replacement with a single prosthesis were analysed at a mean follow-up of 28.3 months (24 to 44) for notching, osteophytes, the position of the glenoid baseplate, the overhang of the glenosphere, and the prosthesis scapular neck angle (PSNA).

A total of 20 patients (13.2%) had a notch (16 Grade 1 and four Grade 2) and 47 (31.1%) had an osteophyte. In patients without either notching or an osteophyte the baseplate was found to be positioned lower on the glenoid, with greater overhang of the glenosphere and a lower PSNA than those with notching and an osteophyte. Female patients had a higher rate of notching than males (13.3% vs 13.0%) but a lower rate of osteophyte formation (22.9% vs 50.0%), even though the baseplate was positioned significantly lower on the glenoid in females (p = 0.009) and each had a similar mean overhang of the glenosphere.

Based on these findings we make recommendations on the placement of the implant in both male and female patients to avoid notching and osteophyte formation.

Cite this article: Bone Joint J 2013;95-B:530–5.