Advertisement for orthosearch.org.uk
Results 1 - 100 of 100
Results per page:
Bone & Joint Open
Vol. 5, Issue 2 | Pages 123 - 131
12 Feb 2024
Chen B Duckworth AD Farrow L Xu YJ Clement ND

Aims. This study aimed to determine whether lateral femoral wall thickness (LWT) < 20.5 mm was associated with increased revision risk of intertrochanteric fracture (ITF) of the hip following sliding hip screw (SHS) fixation when the medial calcar was intact. Additionally, the study assessed the association between LWT and patient mortality. Methods. This retrospective study included ITF patients aged 50 years and over treated with SHS fixation between 2019 and 2021 at a major trauma centre. Demographic information, fracture type, delirium status, American Society of Anesthesiologists grade, and length of stay were collected. LWT and tip apex distance were measured. Revision surgery and mortality were recorded at a mean follow-up of 19.5 months (1.6 to 48). Cox regression was performed to evaluate independent risk factors associated with revision surgery and mortality. Results. The cohort consisted of 890 patients with a mean age of 82 years (SD 10.2). Mean LWT was 27.0 mm (SD 8.6), and there were 213 patients (23.9%) with LWT < 20.5 mm. Overall, 20 patients (2.2%) underwent a revision surgery following SHS fixation. Adjusting for covariates, LWT < 20.5 mm was not independently associated with an increased revision or mortality risk. However, factors that were significantly more prevalent in LWT < 20.5 mm group, which included residence in care home (hazard ratio (HR) 1.84; p < 0.001) or hospital (HR 1.65; p = 0.005), and delirium (HR 1.32; p = 0.026), were independently associated with an increased mortality risk. The only independent factor associated with increased risk of revision was older age (HR 1.07; p = 0.030). Conclusion. LWT was not associated with risk of revision surgery in patients with an ITF fixed with a SHS when the calcar was intact, after adjusting for the independent effect of age. Although LWT < 20.5 mm was not an independent risk factor for mortality, patients with LWT < 20.5 mm were more likely to be from care home or hospital and have delirium on admission, which were associated with a higher mortality rate. Cite this article: Bone Jt Open 2024;5(2):123–131


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 398 - 404
1 Mar 2015
Fang C Lau TW Wong TM Lee HL Leung F

The spiral blade modification of the Dynamic Hip Screw (DHS) was designed for superior biomechanical fixation in the osteoporotic femoral head. Our objective was to compare clinical outcomes and in particular the incidence of loss of fixation. . In a series of 197 consecutive patients over the age of 50 years treated with DHS-blades (blades) and 242 patients treated with conventional DHS (screw) for AO/OTA 31.A1 or A2 intertrochanteric fractures were identified from a prospectively compiled database in a level 1 trauma centre. Using propensity score matching, two groups comprising 177 matched patients were compiled and radiological and clinical outcomes compared. In each group there were 66 males and 111 females. Mean age was 83.6 (54 to 100) for the conventional DHS group and 83.8 (52 to 101) for the blade group. Loss of fixation occurred in two blades and 13 DHSs. None of the blades had observable migration while nine DHSs had gross migration within the femoral head before the fracture healed. There were two versus four implant cut-outs respectively and one side plate pull-out in the DHS group. There was no significant difference in mortality and eventual walking ability between the groups. Multiple logistic regression suggested that poor reduction (odds ratio (OR) 11.49, 95% confidence intervals (CI) 1.45 to 90.9, p = 0.021) and fixation by DHS (OR 15.85, 95%CI 2.50 to 100.3, p = 0.003) were independent predictors of loss of fixation. . The spiral blade design may decrease the risk of implant migration in the femoral head but does not reduce the incidence of cut-out and reoperation. Reduction of the fracture is of paramount importance since poor reduction was an independent predictor for loss of fixation regardless of the implant being used. Cite this article: Bone Joint J 2015;97-B:398–404


Bone & Joint Research
Vol. 9, Issue 12 | Pages 840 - 847
1 Dec 2020
Nie S Li M Ji H Li Z Li W Zhang H Licheng Z Tang P

Aims. Restoration of proximal medial femoral support is the keystone in the treatment of intertrochanteric fractures. None of the available implants are effective in constructing the medial femoral support. Medial sustainable nail (MSN-II) is a novel cephalomedullary nail designed for this. In this study, biomechanical difference between MSN-II and proximal femoral nail anti-rotation (PFNA-II) was compared to determine whether or not MSN-II can effectively reconstruct the medial femoral support. Methods. A total of 36 synthetic femur models with simulated intertrochanteric fractures without medial support (AO/OTA 31-A2.3) were assigned to two groups with 18 specimens each for stabilization with MSN-II or PFNA-II. Each group was further divided into three subgroups of six specimens according to different experimental conditions respectively as follows: axial loading test; static torsional test; and cyclic loading test. Results. The mean axial stiffness, vertical displacement, and maximum failure load of MSN-II were 258.47 N/mm (SD 42.27), 2.99 mm (SD 0.56), and 4,886 N (SD 525.31), respectively, while those of PFNA-II were 170.28 N/mm (SD 64.63), 4.86 mm (SD 1.66), and 3,870.87 N (SD 552.21), respectively. The mean torsional stiffness and failure torque of MSN-II were 1.72 N m/° (SD 0.61) and 16.54 N m (SD 7.06), respectively, while those of PFNA-II were 0.61 N m/° (SD 0.39) and 6.6 N m (SD 6.65), respectively. The displacement of MSN-II in each cycle point was less than that of PFNA-II in cyclic loading test. Significantly higher stiffness and less displacement were detected in the MSN-II group (p < 0.05). Conclusion. The biomechanical performance of MSN-II was better than that of PFNA-II, suggesting that MSN-II may provide more effective mechanical support in the treatment of unstable intertrochanteric fractures. Cite this article: Bone Joint Res 2020;9(12):840–847


Bone & Joint Open
Vol. 4, Issue 10 | Pages 801 - 807
23 Oct 2023
Walter N Szymski D Kurtz SM Lowenberg DW Alt V Lau EC Rupp M

Aims. This work aimed at answering the following research questions: 1) What is the rate of mechanical complications, nonunion and infection for head/neck femoral fractures, intertrochanteric fractures, and subtrochanteric fractures in the elderly USA population? and 2) Which factors influence adverse outcomes?. Methods. Proximal femoral fractures occurred between 1 January 2009 and 31 December 2019 were identified from the Medicare Physician Service Records Data Base. The Kaplan-Meier method with Fine and Gray sub-distribution adaptation was used to determine rates for nonunion, infection, and mechanical complications. Semiparametric Cox regression model was applied incorporating 23 measures as covariates to identify risk factors. Results. Union failure occured in 0.89% (95% confidence interval (CI) 0.83 to 0.95) after head/neck fracturs, in 0.92% (95% CI 0.84 to 1.01) after intertrochanteric fracture and in 1.99% (95% CI 1.69 to 2.33) after subtrochanteric fractures within 24 months. A fracture-related infection was more likely to occur after subtrochanteric fractures than after head/neck fractures (1.64% vs 1.59%, hazard ratio (HR) 1.01 (95% CI 0.87 to 1.17); p < 0.001) as well as after intertrochanteric fractures (1.64% vs 1.13%, HR 1.31 (95% CI 1.12 to 1.52); p < 0.001). Anticoagulant use, cerebrovascular disease, a concomitant fracture, diabetes mellitus, hypertension, obesity, open fracture, and rheumatoid disease was identified as risk factors. Mechanical complications after 24 months were most common after head/neck fractures with 3.52% (95% CI 3.41 to 3.64; currently at risk: 48,282). Conclusion. The determination of complication rates for each fracture type can be useful for informed patient-clinician communication. Risk factors for complications could be identified for distinct proximal femur fractures in elderly patients, which are accessible for therapeutical treatment in the management. Cite this article: Bone Jt Open 2023;4(10):801–807


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 9 | Pages 1253 - 1255
1 Sep 2005
Alam A Willett K Ostlere S

Incomplete intertrochanteric fractures do not extend across to the medial femoral cortex and are stable, without rotational deformity or shortening of the lower limb. The aim of our study was to establish whether they can be successfully managed conservatively. A total of 68 patients over a five-year period presented with a suspected fracture of the femoral neck and underwent an MRI scan for further assessment. From these, we retrospectively reviewed eight patients with normal plain radiographs but with an incomplete, intertrochanteric fracture on MRI scan. Five were managed conservatively and three operatively. The mean length of hospital stay was 16 days for the conservatively-treated group and 15 days for those who underwent surgery; this was not statistically significant (p > 0.5) and all patients were mobilised on discharge. Although five patients were readmitted at a mean of 3.2 years after discharge, none had progressed to a complete fracture. We believe that patients with incomplete intertrochanteric fractures should be considered for conservative treatment


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 956 - 960
1 Jul 2012
Kim T Ha Y Kang B Lee Y Koo K

This prospective multicentre study was undertaken to determine whether the timing of the post-operative administration of bisphosphonate affects fracture healing and the rate of complication following an intertrochanteric fracture. Between August 2008 and December 2009, 90 patients with an intertrochanteric fracture who underwent internal fixation were randomised to three groups according to the timing of the commencement of risedronate treatment after surgery: Group A (from one week after surgery), Group B (from one month after surgery), and Group C (from three months after surgery). The radiological time to fracture healing was assessed as the primary endpoint, and the incidence of complications, including excessive displacement or any complication requiring revision surgery, as the secondary endpoint. The mean time to fracture healing post-operatively in groups A, B and C was 10.7 weeks (. sd. 4.4), 12.9 weeks (. sd. 6.2) and 12.3 weeks (. sd. 7.1), respectively (p = 0.420). At 24 weeks after surgery, all fractures had united, except six that had a loss of fixation. Functional outcomes at one year after surgery according to the Koval classification (p = 0.948) and the incidence of complications (p = 0.386) were similar in the three groups. This study demonstrates that the timing of the post-operative administration of bisphosphonates does not appear to affect the rate of healing of an intertrochanteric fracture or the incidence of complications


Bone & Joint 360
Vol. 12, Issue 1 | Pages 36 - 39
1 Feb 2023

The February 2023 Trauma Roundup. 360. looks at: Masquelet versus bone transport in infected nonunion of tibia; Hyperbaric Oxygen for Lower Limb Trauma (HOLLT): an international multicentre randomized clinical trial; Is the T-shaped acetabular fracture really a “T”?; What causes cut-out of proximal femur nail anti-rotation device in intertrochanteric fractures?; Is the common femoral artery at risk with percutaneous fragility pelvis fixation?; Anterior pelvic ring pattern predicts displacement in lateral compression fractures; Differences in age-related characteristics among elderly patients with hip fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 3 | Pages 390 - 392
1 Mar 2007
Manzotti A Confalonieri N Pullen C

We report the case of a 74-year-old woman who sustained an intertrochanteric fracture of the femoral neck in a previously arthrodesed hip. The hip arthrodesis had been performed 53 years earlier to treat septic arthritis. The fracture was treated successfully using a double-plating technique with 4.5 mm titanium reconstruction plates


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1192 - 1197
1 Sep 2014
Egol KA Marcano AI Lewis L Tejwani NC McLaurin TM Davidovitch RI

In March 2012, an algorithm for the treatment of intertrochanteric fractures of the hip was introduced in our academic department of Orthopaedic Surgery. It included the use of specified implants for particular patterns of fracture. In this cohort study, 102 consecutive patients presenting with an intertrochanteric fracture were followed prospectively (post-algorithm group). Another 117 consecutive patients who had been treated immediately prior to the implementation of the algorithm were identified retrospectively as a control group (pre-algorithm group). The total cost of the implants prior to implementation of the algorithm was $357 457 (mean: $3055 (1947 to 4133)); compared with $255 120 (mean: $2501 (1052 to 4133)) after its implementation. There was a trend toward fewer complications in patients who were treated using the algorithm (33% pre- versus 22.5% post-algorithm; p = 0.088). Application of the algorithm to the pre-algorithm group revealed a potential overall cost saving of $70 295. The implementation of an evidence-based algorithm for the treatment of intertrochanteric fractures reduced costs while maintaining quality of care with a lower rate of complications and re-admissions. Cite this article: Bone Joint J 2014;96-B:1192–7


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 1073 - 1078
1 Aug 2008
Little NJ Verma V Fernando C Elliott DS Khaleel A

We compared the outcome of patients treated for an intertrochanteric fracture of the femoral neck with a locked, long intramedullary nail with those treated with a dynamic hip screw (DHS) in a prospective randomised study. Each patient who presented with an extra-capsular hip fracture was randomised to operative stabilisation with either a long intramedullary Holland nail or a DHS. We treated 92 patients with a Holland nail and 98 with a DHS. Pre-operative variables included the Mini Mental test score, patient mobility, fracture pattern and American Society of Anesthesiologists grading. Peri-operative variables were anaesthetic time, operating time, radiation time and blood loss. Post-operative variables were time to mobilising with a frame, wound infection, time to discharge, time to fracture union, and mortality. We found no significant difference in the pre-operative variables. The mean anaesthetic and operation times were shorter in the DHS group than in the Holland nail group (29.7 vs 40.4 minutes, p < 0.001; and 40.3 vs 54 minutes, p < 0.001, respectively). There was an increased mean blood loss within the DHS group versus the Holland nail group (160 ml vs 78 ml, respectively, p < 0.001). The mean time to mobilisation with a frame was shorter in the Holland nail group (DHS 4.3 days, Holland nail 3.6 days, p = 0.012). More patients needed a post-operative blood transfusion in the DHS group (23 vs seven, p = 0.003) and the mean radiation time was shorter in this group (DHS 0.9 minutes vs Holland nail 1.56 minutes, p < 0.001). The screw of the DHS cut out in two patients, one of whom underwent revision to a Holland nail. There were no revisions in the Holland nail group. All fractures in both groups were united when followed up after one year. We conclude that the DHS can be implanted more quickly and with less exposure to radiation than the Holland nail. However, the resultant blood loss and need for transfusion is greater. The Holland nail allows patients to mobilise faster and to a greater extent. We have therefore adopted the Holland nail as our preferred method of treating intertrochanteric fractures of the hip


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1210 - 1217
1 Sep 2007
Peyser A Weil YA Brocke L Sela Y Mosheiff R Mattan Y Manor O Liebergall M

Limited access surgery is thought to reduce post-operative morbidity and provide faster recovery of function. The percutaneous compression plate (PCCP) is a recently introduced device for the fixation of intertrochanteric fractures with minimal exposure. It has several potential mechanical advantages over the conventional compression hip screw (CHS). Our aim in this prospective, randomised, controlled study was to compare the outcome of patients operated on using these two devices. We randomised 104 patients with intertrochanteric fractures (AO/OTA 31.A1–A2) to surgical treatment with either the PCCP or CHS and followed them for one year postoperatively. The mean operating blood loss was 161.0 ml (8 to 450) in the PCCP group and 374.0 ml (11 to 980) in the CHS group (Student’s t-test, p < 0.0001). The pain score and ability to bear weight were significantly better in the PCCP group at six weeks post-operatively. Analysis of the radiographs in a proportion of the patients revealed a reduced amount of medial displacement in the PCCP group (two patients, 4%) compared with the CHS group (10 patients, 18.9%); Fisher’s exact test, p < 0.02. The PCCP device was associated with reduced intra-operative blood loss, less postoperative pain and a reduced incidence of collapse of the fracture


Aims. There are concerns regarding nail/medullary canal mismatch and initial stability after cephalomedullary nailing in unstable pertrochanteric fractures. This study aimed to investigate the effect of an additional anteroposterior blocking screw on fixation stability in unstable pertrochanteric fracture models with a nail/medullary canal mismatch after short cephalomedullary nail (CMN) fixation. Methods. Eight finite element models (FEMs), comprising four different femoral diameters, with and without blocking screws, were constructed, and unstable intertrochanteric fractures fixed with short CMNs were reproduced in all FEMs. Micromotions of distal shaft fragment related to proximal fragment, and stress concentrations at the nail construct were measured. Results. Micromotions in FEMs without a blocking screw significantly increased as nail/medullary canal mismatch increased, but were similar between FEMs with a blocking screw regardless of mismatch. Stress concentration at the nail construct was observed at the junction of the nail body and lag screw in all FEMs, and increased as nail/medullary canal mismatch increased, regardless of blocking screws. Mean stresses over regions of interest in FEMs with a blocking screw were much lower than regions of interest in those without. Mean stresses in FEMs with a blocking screw were lower than the yield strength, yet mean stresses in FEMs without blocking screws having 8 mm and 10 mm mismatch exceeded the yield strength. All mean stresses at distal locking screws were less than the yield strength. Conclusion. Using an additional anteroposterior blocking screw may be a simple and effective method to enhance fixation stability in unstable pertrochanteric fractures with a large nail/medullary canal mismatch due to osteoporosis. Cite this article: Bone Joint Res 2022;11(3):152–161


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 4 | Pages 572 - 578
1 May 2001
Olsson O Ceder L Hauggaard A

We compared 54 patients treated by a Medoff sliding plate (MSP) with 60 stabilised by a compression hip screw (CHS) in a prospective, randomised study of the management of intertrochanteric femoral fractures. Four months after the operation femoral shortening was determined from radiographs of both femora. In unstable fractures the mean femoral shortening was 15 mm with the MSP and 11 mm with the CHS (p = 0.03). A subgroup in which shortening was classified as large, comprising one-third of the patients in each group, had a similar extent of shortening, but more medialisation of the femoral shaft occurred in the CHS (26%) than in the MSP (12%) group (p = 0.03). Five postoperative failures of fixation occurred with the CHS and none with the MSP (p = 0.03). The marginally greater femoral shortening seen with the MSP compared with the CHS appeared to be justified by the improved control of impaction of the fracture. Biaxial dynamisation in unstable intertrochanteric fractures is a safe principle of treatment, which minimises the rate of postoperative failure of fixation


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 6 | Pages 955 - 958
1 Nov 1991
Dhal A Varghese M Bhasin V

External fixation was used in the treatment of 154 intertrochanteric fractures of the femur over a period of eight years. Good fixation and early ambulation was achieved in all cases. Blood loss was slight. There were 12 deaths due to medical causes unrelated to the surgical procedure. Deep pin-track infection occurred in six cases and late displacement of the fracture fragments in nine. The average time for union was 16 weeks. The technique is simple, quick and inexpensive, and causes minimal surgical trauma. All these features are particularly relevant where resources are limited


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 1 | Pages 37 - 40
1 Jan 1990
Flores L Harrington I Heller M

Failure of fixation is a major complication of the treatment of unstable intertrochanteric fractures. A retrospective review was performed of 54 such fractures treated with a sliding screw-plate device. Linear and angular displacements were calculated from radiographs taken at operation and serially until healing was complete. Linear displacement was related to fracture instability, but the neck-shaft angle was relatively constant during healing. Complications were often due to failure of the sliding mechanism of the implant. We conclude that a sliding screw-plate allows controlled collapse of the major fragments but maintains the neck-shaft angle even in unstable fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 3 | Pages 445 - 447
1 May 1993
Desjardins A Roy A Paiement G Newman N Pedlow F Desloges D Turcotte R

We conducted a prospective randomised trial to compare the results of anatomical reduction and medial displacement osteotomy in 127 consecutive patients with unstable intertrochanteric fractures, of whom 109 completed the study. After an average follow-up of 11 months, we found no significant differences in walking ability, social status or failure of fixation in the two groups. Postoperative complication rates and the early mortality rate were not significantly different, but operating time and blood loss were significantly higher in the osteotomy group. With the use of modern sliding hip screws, medial displacement osteotomy is rarely indicated for unstable intertrochanteric fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 3 | Pages 262 - 267
1 May 1983
Heyse-Moore G MacEachern A Evans D

One hundred and seven patients with intertrochanteric fractures of the femur treated with a Richards screw-plate were compared retrospectively with 103 patients treated with a Jewett nail-plate. The mortality and morbidity were similar in the two groups. In patients with comparable fractures, those treated with a Richards device mobilised more quickly and left hospital sooner, and more of them returned to their homes. Failures of stabilisation, both clinically and radiographically, were fewer in this group. The reliability of fixation with a correctly positioned Richards screw-plate could justify the omission of outpatient follow-up in all but a small group of patients with severe unstable fractures or grossly defective bone stock. The higher cost of a Richards implant and the slightly longer operative procedure were outweighed by savings in occupancy of acute and long-stay hospital beds


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 1 | Pages 90 - 92
1 Jan 1995
Sarathy M Madhavan P Ravichandran K

Nonunion of intertrochanteric fractures is uncommon but its effects are disabling. We describe a modification of the medial displacement and valgus osteotomy of Dimon and Hughston (1967) which we used in seven fractures, six of which united within 16 weeks. Postoperatively, hip function was good. The method provides good initial stability, a source of cancellous bone graft, good postoperative hip abductor function and reliable healing of the nonunion without the need for intraoperative imaging


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 430 - 434
1 May 2024
Eardley WGP


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 2 | Pages 330 - 334
1 Mar 1991
Bridle S Patel A Bircher M Calvert P

We have prospectively compared the fixation of 100 intertrochanteric fractures of the proximal femur in elderly patients with random use of either a Dynamic Hip Screw (DHS) or a new intramedullary device, the Gamma nail. We found no difference in operating time, blood loss, wound complications, stay in hospital, place of eventual discharge, or the patients' mobility at final review. There was no difference in failure of proximal fixation: cut-out occurred in three cases with the DHS, and twice with the Gamma nail. However, in four cases fracture of the femur occurred close to the Gamma nail, requiring further major surgery. In the absence of these complications, union was seen by six months in both groups


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 19 - 22
1 Jan 2002
Kosygan KP Mohan R Newman RJ

We performed a randomised, prospective trial in 111 patients with intertrochanteric fractures of the hip comparing the use of the Gotfried percutaneous compression plate (PCCP) with that of the classic hip screw (CHS). Blood loss and transfusion requirement were less in the PCCP group but the operating time was significantly longer. The complication rate after operation was similar in both groups, and at a minimum follow-up of six months there was no difference in the rates of fracture healing or implant failure. The PCCP gives results which are similar to those obtained with a conventional device. Its suggested advantages seem to be theoretical rather than practical and, being a fixed-angle implant, it is not universally applicable


Bone & Joint 360
Vol. 11, Issue 1 | Pages 38 - 41
1 Feb 2022


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 3 | Pages 477 - 478
1 May 1992
Weber P


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 5 | Pages 789 - 792
1 Sep 1994
Gargan M Gundle R Simpson A

Osteotomy has been used in the treatment of unstable intertrochanteric hip fractures in an attempt to increase the stability of the fracture fragments. We have assessed this stability in a randomised prospective trial on 100 consecutive patients, all having fixation by an AO dynamic hip screw, comparing anatomical reduction with two types of osteotomy. The groups were similar in terms of age, gender, mental test score, and fracture configuration. There were more failures of fixation in the osteotomy groups, and the operations took longer. We found no clear benefit from osteotomy and therefore recommend anatomical reduction and fixation by a sliding hip screw in most cases. Rarely, a fracture configuration which does not allow load-sharing between the fracture fragments and the device may benefit from an osteotomy or the use of an alternative implant.


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 1 | Pages 24 - 28
1 Feb 1981
Hall G Ainscow D

Two comparable groups of patients with fractures of the trochanteric region of the femur were studied. One hundred and sixty-five fractures had been fixed with conventional nail-plates and 132 with Ender's nails. Ender's nails gave superior results in the treatment of trochanteric fractures. The operation was quicker and less traumatic than that using conventional nail-plates and both the mortality rate and the time in hospital were reduced. More patients in the group with Ender's nails who were initially independent returned to an independent existence.


The Journal of Bone & Joint Surgery British Volume
Vol. 50-B, Issue 1 | Pages 141 - 143
1 Feb 1968
Fordyce A


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 1 | Pages 148 - 148
1 Jan 2003
GOTFRIED Y


The Bone & Joint Journal
Vol. 101-B, Issue 6_Supple_B | Pages 91 - 96
1 Jun 2019
Smith A Denehy K Ong KL Lau E Hagan D Malkani A

Aims. Cephalomedullary nails (CMNs) are commonly used for the treatment of intertrochanteric hip fractures. Total hip arthroplasty (THA) may be used as a salvage procedure when fixation fails in these patients. The aim of this study was to analyze the complications of THA following failed intertrochanteric hip fracture fixation using a CMN. Patients and Methods. Patients who underwent THA were identified from the 5% subset of Medicare Parts A/B between 2002 and 2015. A subgroup involving those with an intertrochanteric fracture that was treated using a CMN during the previous five years was identified and compared with the remaining patients who underwent THA. The length of stay (LOS) was compared using both univariate and multivariate analysis. The incidence of infection, dislocation, revision, and re-admission was compared between the two groups, using multivariate analysis adjusted for demographic, hospital, and clinical factors. Results. The Medicare data yielded 56 522 patients who underwent primary THA, of whom 369 had previously been treated with a CMN. The percentage of THAs that were undertaken between 2002 and 2005 in patients who had previously been treated with a CMN (0.346%) more than doubled between 2012 and 2015 (0.781%). The CMN group tended to be older and female, and to have a higher Charlson Comorbidity Index and lower socioeconomic status. The mean LOS was 1.5 days longer (5.3 vs 3.8) in the CMN group (p < 0.0001). The incidence of complications was significantly higher in the CMN group compared with the non-CMN group: infection (6.2% vs 2.6%), dislocation (8.1% vs 4.5%), revision (8.4% vs 4.3%), revision for infection (1.1% vs 0.37%), and revision for dislocation (2.2% vs 0.6%). Conclusion. The incidence of conversion to THA following failed intertrochanteric hip fracture fixation using a CMN continues to increase. This occurs in elderly patients with increased comorbidities. There is a significantly increased risk of infection, dislocation, and LOS in these patients. Patients with failed intertrochanteric hip fracture fixation using a CMN who require THA should be made aware of the increased risk of complications, and steps need to be taken to reduce this risk. Cite this article: Bone Joint J 2019;101-B(6 Supple B):91–96


The Bone & Joint Journal
Vol. 99-B, Issue 1 | Pages 128 - 133
1 Jan 2017
Socci AR Casemyr NE Leslie MP Baumgaertner MR

Aims. The aim of this paper is to review the evidence relating to the anatomy of the proximal femur, the geometry of the fracture and the characteristics of implants and methods of fixation of intertrochanteric fractures of the hip. Materials and Methods. Relevant papers were identified from appropriate clinical databases and a narrative review was undertaken. Results. Stable, unstable, and subtrochanteric intertrochanteric fractures vary widely in their anatomical and biomechanical characteristics, as do the implants used for their fixation. The optimal choice of implant addresses the stability of the fracture and affects the outcome. Conclusion. The treatment of intertrochanteric fractures of the hip has evolved along with changes in the design of the implants used to fix them, but there remains conflicting evidence to guide the choice of implant. We advocate fixation of 31A1 fractures with a sliding hip screw and all others with an intramedullary device. Cite this article: Bone Joint J 2017;99-B:128–33


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 8 | Pages 1064 - 1068
1 Aug 2009
Sankey RA Turner J Lee J Healy J Gibbons CER

An MR scan was performed on all patients who presented to our hospital with a clinical diagnosis of a fracture of the proximal femur, but who had no abnormality on plain radiographs. This was a prospective study of 102 consecutive patients over a ten-year period. There were 98 patients who fulfilled our inclusion criteria, of whom 75 were scanned within 48 hours of admission, with an overall mean time between admission and scanning of 2.4 days (0 to 10). A total of 81 patients (83%) had abnormalities detected on MRI; 23 (23%) required operative management. The use of MRI led to the early diagnosis and treatment of occult hip pathology. We recommend that incomplete intertrochanteric fractures are managed non-operatively with protected weight-bearing. The study illustrates the high incidence of fractures which are not apparent on plain radiographs, and shows that MRI is useful when diagnosing other pathology such as malignancy, which may not be apparent on plain films


Bone & Joint Open
Vol. 5, Issue 6 | Pages 524 - 531
24 Jun 2024
Woldeyesus TA Gjertsen J Dalen I Meling T Behzadi M Harboe K Djuv A

Aims

To investigate if preoperative CT improves detection of unstable trochanteric hip fractures.

Methods

A single-centre prospective study was conducted. Patients aged 65 years or older with trochanteric hip fractures admitted to Stavanger University Hospital (Stavanger, Norway) were consecutively included from September 2020 to January 2022. Radiographs and CT images of the fractures were obtained, and surgeons made individual assessments of the fractures based on these. The assessment was conducted according to a systematic protocol including three classification systems (AO/Orthopaedic Trauma Association (OTA), Evans Jensen (EVJ), and Nakano) and questions addressing specific fracture patterns. An expert group provided a gold-standard assessment based on the CT images. Sensitivities and specificities of surgeons’ assessments were estimated and compared in regression models with correlations for the same patients. Intra- and inter-rater reliability were presented as Cohen’s kappa and Gwet’s agreement coefficient (AC1).


Bone & Joint 360
Vol. 13, Issue 2 | Pages 35 - 38
1 Apr 2024

The April 2024 Trauma Roundup360 looks at: The infra-acetabular screw in acetabular fracture surgery; Is skin traction helpful in patients with intertrochanteric hip fractures?; Reducing pain and improving function following hip fracture surgery; Are postoperative splints helpful following ankle fracture fixation?; Biomechanics of internal fixation in Hoffa fractures: a comparison of four different constructs; Dual-plate fixation of periprosthetic distal femur fractures; Do direct oral anticoagulants necessarily mean a delay to hip fracture surgery?; Plate or retrograde nail for low distal femur fractures?.


The Journal of Bone & Joint Surgery British Volume
Vol. 44-B, Issue 3 | Pages 520 - 527
1 Aug 1962
Stevens J Freeman PA Nordin BEC Barnett E

1. Recently described histological and radiographic methods of diagnosing osteoporosis have been applied to patients with transcervical and intertrochanteric fractures of the femur. 2. Both methods indicate a higher incidence of osteoporosis in such patients than in a control series, especially in older women with intertrochanteric fractures. 3. A discrepancy between the results of biopsy and radiographic examination was encountered, the explanation of which is not yet clear


Bone & Joint Open
Vol. 5, Issue 6 | Pages 457 - 463
2 Jun 2024
Coviello M Abate A Maccagnano G Ippolito F Nappi V Abbaticchio AM Caiaffa E Caiaffa V

Aims

Proximal femur fractures treatment can involve anterograde nailing with a single or double cephalic screw. An undesirable failure for this fixation is screw cut-out. In a single-screw nail, a tip-apex distance (TAD) greater than 25 mm has been associated with an increased risk of cut-out. The aim of the study was to examine the role of TAD as a risk factor in a cephalic double-screw nail.

Methods

A retrospective study was conducted on 112 patients treated for intertrochanteric femur fracture with a double proximal screw nail (Endovis BA2; EBA2) from January to September 2021. The analyzed variables were age, sex, BMI, comorbidities, fracture type, side, time of surgery, quality of reduction, pre-existing therapy with bisphosphonate for osteoporosis, screw placement in two different views, and TAD. The last follow-up was at 12 months. Logistic regression was used to study the potential factors of screw cut-out, and receiver operating characteristic curve to identify the threshold value.


The Journal of Bone & Joint Surgery British Volume
Vol. 39-B, Issue 3 | Pages 451 - 457
1 Aug 1957
Kennedy JC McFarlane RM McLachlin AD

1. The Moe plate has been used in 256 of 270 consecutive intertrochanteric fractures of the femur. There was an operative mortality of l8·8 per cent and an overall mortality of 20·7 per cent in a group averaging 75·2 years of age. 2. The method proved satisfactory, giving secure fixation and also approximation of the fragments by the lag action of the three large screws driven into the head. There was only one case of non-union. 3. In the survivors anatomical and functional results have been satisfactory in about 70 per cent, with half of these showing full functional recovery and the other half requiring only occasional use of a stick or crutch. 4. There are a few intertrochanteric fractures of the femur too comminuted for any form of internal fixation. Traction should be used in this group. 5. A varus deformity developed in about one half of the cases. This is consistent with a good functional result. 6. The main difficulty in these aged people has been survival. The problems have been discussed with suggestions that may perhaps reduce in part a mortality that seems inherent in this injury and at this age


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 5 | Pages 582 - 583
1 Nov 1983
MacEachern A Heyse-Moore G

Intertrochanteric fractures of the femur are usually classified into stable and unstable groups, partly to predict the likelihood of displacement with early weight-bearing after internal fixation. Of 82 internally fixed intertrochanteric fractures which would normally be classified as stable, 25 subsequently underwent impaction along the axis of the nail or screw; varus displacement occurred in another six. Of these 31 fractures, 10 were two-part fractures which had been anatomically reduced, and 12 were originally undisplaced. It did not seem possible to predict the subsequent instability from the pre-operative radiographs. Of the 82 fractures, 47 had been treated with a Jewett nail-plate and 35 by a Richards compression screw-plate. Two groups of stable fractures were recognised: Group 1 was undisplaced and Group 2 displaced. Axial impaction occurred in a quarter of all Group 1 fractures however treated. In Group 2 fractures it occurred in a quarter of those treated with a nail-plate, and in over a third of those treated with a sliding screw-plate. The six fractures that underwent varus displacement had all been treated with Jewett nail-plates. Penetration into the joint occurred in 10 patients, all of them in the group treated with Jewett nail-plates; four required re-operation


Bone & Joint 360
Vol. 12, Issue 5 | Pages 36 - 39
1 Oct 2023

The October 2023 Trauma Roundup360 looks at: Intramedullary nailing versus sliding hip screw in trochanteric fracture management: the INSITE randomized clinical trial; Five-year outcomes for patients with a displaced fracture of the distal tibia; Direct anterior versus anterolateral approach in hip joint hemiarthroplasty; Proximal humerus fractures: treat them all nonoperatively?; Tranexamic acid administration by prehospital personnel; Locked plating versus nailing for proximal tibia fractures: a multicentre randomized controlled trial; A retrospective review of the rate of septic knee arthritis after retrograde femoral nailing for traumatic femoral fractures at a single academic institution.


Bone & Joint Open
Vol. 4, Issue 7 | Pages 516 - 522
10 Jul 2023
Mereddy P Nallamilli SR Gowda VP Kasha S Godey SK Nallamilli RR GPRK R Meda VGR

Aims

Musculoskeletal infection is a devastating complication in both trauma and elective orthopaedic surgeries that can result in significant morbidity. Aim of this study was to assess the effectiveness and complications of local antibiotic impregnated dissolvable synthetic calcium sulphate beads (Stimulan Rapid Cure) in the hands of different surgeons from multiple centres in surgically managed bone and joint infections.

Methods

Between January 2019 and December 2022, 106 patients with bone and joint infections were treated by five surgeons in five hospitals. Surgical debridement and calcium sulphate bead insertion was performed for local elution of antibiotics in high concentration. In all, 100 patients were available for follow-up at regular intervals. Choice of antibiotic was tailor made for each patient in consultation with microbiologist based on the organism grown on culture and the sensitivity. In majority of our cases, we used a combination of vancomycin and culture sensitive heat stable antibiotic after a thorough debridement of the site. Primary wound closure was achieved in 99 patients and a split skin graft closure was done in one patient. Mean follow-up was 20 months (12 to 30).


The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1149 - 1158
1 Nov 2023
Chen B Zhang JH Duckworth AD Clement ND

Aims

Hip fractures are a major cause of morbidity and mortality, and malnutrition is a crucial determinant of these outcomes. This meta-analysis aims to determine whether oral nutritional supplementation (ONS) improves postoperative outcomes in older patients with a hip fracture.

Methods

A systematic literature search was conducted in August 2022. ONS was defined as high protein-based diet strategies containing (or not containing) carbohydrates, fat, vitamins, and minerals. Randomized trials documenting ONS in older patients with hip fracture (aged ≥ 50 years) were included. Two reviewers evaluated study eligibility, conducted data extraction, and assessed study quality.


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1182 - 1189
1 Oct 2024
Nisar S Lamb J Johansen A West R Pandit H

Aims

To determine if patient ethnicity among patients with a hip fracture influences the type of fracture, surgical care, and outcome.

Methods

This was an observational cohort study using a linked dataset combining data from the National Hip Fracture Database and Hospital Episode Statistics in England and Wales. Patients’ odds of dying at one year were modelled using logistic regression with adjustment for ethnicity and clinically relevant covariates.


The Bone & Joint Journal
Vol. 104-B, Issue 12 | Pages 1369 - 1378
1 Dec 2022
van Rijckevorsel VAJIM de Jong L Verhofstad MHJ Roukema GR

Aims

Factors associated with high mortality rates in geriatric hip fracture patients are frequently unmodifiable. Time to surgery, however, might be a modifiable factor of interest to optimize clinical outcomes after hip fracture surgery. This study aims to determine the influence of postponement of surgery due to non-medical reasons on clinical outcomes in acute hip fracture surgery.

Methods

This observational cohort study enrolled consecutively admitted patients with a proximal femoral fracture, for which surgery was performed between 1 January 2018 and 11 January 2021 in two level II trauma teaching hospitals. Patients with medical indications to postpone surgery were excluded. A total of 1,803 patients were included, of whom 1,428 had surgery < 24 hours and 375 had surgery ≥ 24 hours after admission.


Bone & Joint Research
Vol. 11, Issue 2 | Pages 102 - 111
1 Feb 2022
Jung C Cha Y Yoon HS Park CH Yoo J Kim J Jeon Y

Aims

In this study, we aimed to explore surgical variations in the Femoral Neck System (FNS) used for stable fixation of Pauwels type III femoral neck fractures.

Methods

Finite element models were established with surgical variations in the distance between the implant tip and subchondral bone, the gap between the plate and lateral femoral cortex, and inferior implant positioning. The models were subjected to physiological load.


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 274 - 282
1 Feb 2022
Grønhaug KML Dybvik E Matre K Östman B Gjertsen J

Aims

The aim of this study was to investigate if there are differences in outcome between sliding hip screws (SHSs) and intramedullary nails (IMNs) with regard to fracture stability.

Methods

We assessed data from 17,341 patients with trochanteric or subtrochanteric fractures treated with SHS or IMN in the Norwegian Hip Fracture Register from 2013 to 2019. Primary outcome measures were reoperations for stable fractures (AO Foundation/Orthopaedic Trauma Association (AO/OTA) type A1) and unstable fractures (AO/OTA type A2, A3, and subtrochanteric fractures). Secondary outcome measures were reoperations for A2, A3, and subtrochanteric fractures individually, one-year mortality, quality of life (EuroQol five-dimension three-level index score), pain (visual analogue scale (VAS)), and satisfaction (VAS) for stable and unstable fractures. Hazard rate ratios (HRRs) for reoperation were calculated using Cox regression analysis with adjustments for age, sex, and American Society of Anesthesiologists score.


The Journal of Bone & Joint Surgery British Volume
Vol. 55-B, Issue 3 | Pages 575 - 580
1 Aug 1973
Jenkins DHR Roberts JG Webster D Williams EO

1. Seventy-four patients over the age of seventy with either subcapital or intertrochanteric fracture have been investigated for evidence of osteomalacia. To establish an index of suspicion the incidence of biochemically defined osteomalacia has been compared with quantitative histology in this group. 2. Whereas no significant difference in the incidence of the disease was noted in the comparison of subcapital with trochanteric fracture groups, there was a high incidence of osteomalacia overall. Furthermore, a subclinical form of the disease appears to exist. 3. The relevance of these observations is discussed with particular reference to the established diagnostic criteria of the condition


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 1 | Pages 78 - 82
1 Jan 1986
Skinner P Powles D

We report a prospective study of 198 cases of subcapital fracture of the femur treated by closed reduction and fixation with a sliding compression screw-plate. This was done without regard to the patient's age or the Garden stage of the fracture. Early weight-bearing was encouraged. Of the displaced fractures 23% failed in the first year because of non-union or infection. Of the fractures which united 27% had developed avascular necrosis after three years. Despite this we believe that the sliding compression screw-plate, of proven value in the treatment of intertrochanteric fractures, is also useful for the fixation of subcapital fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 4 | Pages 596 - 599
1 Jul 1999
Konishiike T Makihata E Tago H Sato T Inoue H

We performed dynamic MRI of the femoral head within 48 hours of injury on 22 patients with subcapital fracture of the neck of the femur and on a control group of 20 of whom ten were healthy subjects and ten were patients with an intertrochanteric fracture. Three MRI patterns emerged when the results between the fractured side and the contralateral femoral head were compared. In all of the control group and in those patients who had undisplaced fractures (Garden stages I and II), perfusion of the femoral head was considered to be at the same level as on the unaffected side. In patients with displaced fractures (Garden stages III and IV) almost all the femoral heads on the fractured side were impaired or totally avascular, although some had the same level of perfusion as the unaffected side. We conclude that dynamic MRI, a new non-invasive imaging technique, is useful for evaluating the perfusion of the femoral head


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 3 | Pages 387 - 390
1 May 1996
Lunsjö K Ceder L Stigsson L Hauggaard A

The Medoff sliding plate (MSP) is a new device used to treat intertrochanteric and subtrochanteric fractures. There are three options for sliding; either along the shaft or the neck of the femur, or a combination of both. In a prospective series of 108 consecutive displaced intertrochanteric fractures we used combined dynamic compression. The patients were followed clinically and radiologically for one year. All fractures healed during the follow-up period. The only postoperative technical failure was one lag-screw penetration. Combined compression of the MSP gives increased dynamic capacity which reduces the risk of complications. The low rate of technical failure in our series compares favourably with that of the sliding hip screw or the Gamma nail but randomised trials comparing the MSP with other hip screw systems are necessary to find the true role of the MSP with its various sliding modes


Bone & Joint Open
Vol. 1, Issue 10 | Pages 644 - 653
14 Oct 2020
Kjærvik C Stensland E Byhring HS Gjertsen J Dybvik E Søreide O

Aims

The aim of this study was to describe variation in hip fracture treatment in Norway expressed as adherence to international and national evidence-based treatment guidelines, to study factors influencing deviation from guidelines, and to analyze consequences of non-adherence.

Methods

International and national guidelines were identified and treatment recommendations extracted. All 43 hospitals routinely treating hip fractures in Norway were characterized. From the Norwegian Hip Fracture Register (NHFR), hip fracture patients aged > 65 years and operated in the period January 2014 to December 2018 for fractures with conclusive treatment guidelines were included (n = 29,613: femoral neck fractures (n = 21,325), stable trochanteric fractures (n = 5,546), inter- and subtrochanteric fractures (n = 2,742)). Adherence to treatment recommendations and a composite indicator of best practice were analyzed. Patient survival and reoperations were evaluated for each recommendation.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 6 | Pages 872 - 875
1 Aug 2000
Schnaid E MacPhail AP Sweet MBE

We explored the role of iron overload, deficiency of vitamin C and alcohol abuse in the aetiology of cervical and intertrochanteric fractures of the neck of the femur as a result of minor trauma. We studied prospectively 72 patients (45 men, 27 women). Levels of serum iron markers, vitamin C and alcohol markers were measured. Consumption of alcohol was estimated using questionnaires. The findings were compared with those of an age- and gender-matched control group. The mean age of the men was 59.5 years and of the women 66.9 years, with a male predominance. In the men, iron overload, as shown by high levels of serum ferritin (p < 0.001) and deficiency of vitamin C (p < 0.03), as well as abuse of both Western and the traditional type of alcohol, appear to be important aetiological factors. In women, alcohol abuse was also common, but iron markers and levels of vitamin C did not differ significantly from the control group


The Journal of Bone & Joint Surgery British Volume
Vol. 59-B, Issue 4 | Pages 398 - 401
1 Nov 1977
Sikorski J Millar A

The records of 107 patients with displaced subcaptial hip fractures treated by Thompson's femoral head replacements have been reviewed to determine the mortality and certain aspects of systemic morbidity. Comparison was made with a group, matched exactly for age and sex, in which intertrochanteric fractures were treated by nail-plate fixation. The patients treated by Thompson's arthroplasty were further subdivided into two groups: one in which methylacrylic cement was used, and one in which it was not used. We found no difference in the mortality of the patients undergoing replacement arthroplasty and nail-plate fixation. Similarly there was no difference in the incidence of cerebrovascular incidents and myocardial infarction after operation. There was a higher incidence of transient cardiac failure following Thompson's arthroplasty. Hypotension during the operation occurred irrespective of whether cement was used; nor was the use of cement associated with increased mortality. However, it seems that methylacrylic cement does contribute to the cardiac failure that may occur after Thompson's arthroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 1 | Pages 7 - 10
1 Jan 1991
Bogoch E Ouellette G Hastings D

We reviewed the records and radiographs from 10 hospitals to identify 50 patients with rheumatoid arthritis (RA) who had sustained 52 femoral neck fractures. Most patients were female (88%), elderly (mean age 66 years) and had had severe polyarticular disease for a mean duration of 16 years. Over half had taken systemic corticosteroids, nearly all were severely osteopenic but few had rheumatoid changes in the hip. Of the 20 fractures treated by internal fixation 12 had complications including nonunion (5), osteonecrosis (5), infection (1), and intertrochanteric fracture (1). Only one of the nine undisplaced fractures required reoperation, but seven of the 11 displaced fractures had revision surgery. Twenty fractures were treated by primary total hip arthroplasty with only one early complication. The other 12 fractures had been treated by hemiarthroplasty (9), hip excision (1) or non-operatively (2). Our results suggest that, in elderly rheumatoid patients, severely displaced femoral neck fractures should be treated by total hip replacement


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 25 - 32
1 Jul 2021
Amstutz HC Le Duff MJ

Aims

Adverse local tissue reactions associated with abnormal wear considerably slowed down the general use of metal-on-metal (MoM) hip resurfacing arthroplasty (HRA), now limited to a few specialized centres. In this study, we provide the clinical results of 400 consecutive MoM HRAs implanted more than 20 years ago in one such centre.

Methods

A total of 355 patients (400 hips) were treated with Conserve Plus HRA between November 1996 and November 2000. There were 96 female (27%) and 259 male patients (73%). Their mean age was 48.2 years (SD 10.9). The University of California, Los Angeles (UCLA) hip scores and 12-item Short Form Survey (SF-12) quality of life scores were reported. Survivorship was assessed using Kaplan-Meier analyses.


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 440 - 441
1 Mar 2021
Nikolaou VS Masouros P Floros T Chronopoulos E Skertsou M Babis GC


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 3 | Pages 352 - 357
1 May 1992
Rosenblum S Zuckerman J Kummer F Tam B

We examined the effect of the Gamma nail on strain distribution in the proximal femur, using ten cadaver femora instrumented with six unidirectional strain gauges along the medial and lateral cortices. The femora were loaded to 1800 N and strains were determined with or without distal interlocking screws before and after experimentally created two-part and four-part fractures. Motion of the sliding screw and the nail was also determined. Strain patterns and screw motion were compared with previously obtained values for a sliding hip screw device (SHS). The Gamma nail was shown to transmit decreasing load to the calcar with decreasing fracture stability, such that virtually no strain on the bone was seen in four-part fractures with the posteromedial fragment removed; increasing compression was noted, however, at the proximal lateral cortex. Conversely, the SHS showed increased calcar compression with decreasing fracture stability. The insertion of distal interlocking screws did not change the pattern of proximal femoral strain. The Gamma nail imparts non-physiological strains to the proximal femur, probably because of its inherent stiffness. These strains may alter bone remodelling and interfere with healing. Distal interlocking screws may not be necessary for stable intertrochanteric fractures


Bone & Joint 360
Vol. 9, Issue 4 | Pages 15 - 17
1 Aug 2020


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 2 | Pages 277 - 283
1 Mar 1995
Choueka J Koval K Kummer F Crawford G Zuckerman J

We studied the biomechanical behaviour of three sliding fixation devices for trochanteric femoral fractures. These were a titanium alloy sideplate and lag screw, a titanium alloy sideplate and dome plunger with cement augmentation, and a stainless-steel sideplate and lag screw. We used 18 mildly osteoporotic cadaver femora, randomly assigned to one of the three fixation groups. Four displacement and two strain gauges were fixed to each specimen, and each femur was first tested intact (control), then as a two-part fracture and then as a four-part intertrochanteric fracture. A range of physiological loads was applied to determine load-bearing, load-sharing and head displacement. The four-part-fracture specimens were subsequently tested to failure to determine maximum fixation strengths and modes of failure. The dome-plunger group failed at a load 50% higher than that of the stainless-steel lag-screw group (p < 0.05) and at a load 20% higher than that of the titanium-alloy lag-screw group (NS). All 12 lag-screw specimens failed by cut-out through the femoral head or neck, but none of the dome-plunger group showed movement within the femoral head when tested to failure. Strain-gauge analysis showed that the dome plunger produced considerably less strain in the inferior neck and calcar region than either of the lag screws. Inferior displacement of the femoral head was greatest for the dome-plunger group, and was due to sliding of the plunger. The dome plunger with cement augmentation was able to support higher loads and did not fail by cut-out through the femoral head.(ABSTRACT TRUNCATED AT 250 WORDS)


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 7 | Pages 967 - 971
1 Sep 2000
Patton JT Cook RE Adams CI Robinson CM

In a consecutive series of 498 patients with 528 fractures of the femur treated by conventional interlocking intramedullary nailing, 14 fractures of the femoral neck (2.7%) occurred in 13 patients. The fracture of the hip was not apparent either before operation or on the immediate postoperative radiographs. It was diagnosed in the first two weeks after operation in three patients and after three months in the remainder. Age over 60 years at the time of the femoral fracture and female gender were significantly predictive of hip fracture on bivariate logistic regression analysis, but on multivariate analysis only the location of the original fracture in the proximal third of the femur (p = 0.0022, odds ratio = 6.96, 95% CI 2.01 to 24.14), low-energy transfer (p = 0.0264, odds ratio = 15.56, 95% CI 1.38 to 75.48) and the severity of osteopenia on radiographs (p = 0.0128, odds ratio = 7.55, 95% CI 1.54 to 37.07) were significant independent predictors of later fracture. Five of the 19 women aged over 60 years, who sustained an osteoporotic proximal diaphyseal fracture of the femur during a simple fall, subsequently developed a fracture of the neck. Eleven of the hip fractures were displaced and intracapsular and, in view of the advanced age of most of these patients, were usually treated by replacement arthroplasty. Reduction and internal fixation was used to treat the remaining three intertrochanteric fractures. Three patients developed complications requiring further surgery; five died within two years of their fracture


The Journal of Bone & Joint Surgery British Volume
Vol. 42-B, Issue 1 | Pages 21 - 27
1 Feb 1960
Arden GP

1. A method is described for measuring blood flow to the head of the femur after fracture of the femoral neck, by estimation of the rate of uptake of radioactive phosphorus. 2. Of one hundred cases investigated the readings in fifteen were incomplete, and in seventeen were unreliable. Reasons are given for discarding the latter seventeen cases. After two years seven patients had died, leaving sixty-one available for analysis. 3. The results in sixty-one surviving patients with a follow-up of not less than two years are analysed. In twenty of these radioactivity was measured by bone sampling and in forty-one by direct readings with a needle counter. 4. The twenty-one intertrochanteric fractures studied were used as controls. In these the P. 32. ratio varied from 0·4 to 3·0. Union occurred in all patients and none developed avascular necrosis. 5. Of the forty patients with displaced fractures of the femoral neck twenty-eight showed a low P. 32. ratio. In twenty-three of these (82 per cent) the fracture united. 6. Twelve patients with fractures of the femoral neck showed a borderline or abnormal P. 32. ratio. In ten of these there was subsequent avascular necrosis or non-union. 7. The possible reasons for the discrepancy between expected and actual results are discussed. 8. Almost 40 per cent of the cases investigated had to be abandoned because of technical faults and in one-fifth of the remaining cases the expected results failed to agree with the clinical results. The method of investigation is therefore not of much practical value at the present time. Improvements in apparatus and technique might make the method more reliable and more useful


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 162 - 169
1 Feb 2020
Hoellwarth JS Tetsworth K Kendrew J Kang NV van Waes O Al-Maawi Q Roberts C Al Muderis M

Aims

Osseointegrated prosthetic limbs allow better mobility than socket-mounted prosthetics for lower limb amputees. Fractures, however, can occur in the residual limb, but they have rarely been reported. Approximately 2% to 3% of amputees with socket-mounted prostheses may fracture within five years. This is the first study which directly addresses the risks and management of periprosthetic osseointegration fractures in amputees.

Methods

A retrospective review identified 518 osseointegration procedures which were undertaken in 458 patients between 2010 and 2018 for whom complete medical records were available. Potential risk factors including time since amputation, age at osseointegration, bone density, weight, uni/bilateral implantation and sex were evaluated with multiple logistic regression. The mechanism of injury, technique and implant that was used for fixation of the fracture, pre-osseointegration and post fracture mobility (assessed using the K-level) and the time that the prosthesis was worn for in hours/day were also assessed.


Bone & Joint Open
Vol. 1, Issue 11 | Pages 669 - 675
1 Nov 2020
Ward AE Tadross D Wells F Majkowski L Naveed U Jeyapalan R Partridge DG Madan S Blundell CM

Aims

Within the UK, around 70,000 patients suffer neck of femur (NOF) fractures annually. Patients presenting with this injury are often frail, leading to increased morbidity and a 30-day mortality rate of 6.1%. COVID-19 infection has a broad spectrum of clinical presentations with the elderly, and those with pre-existing comorbidities are at a higher risk of severe respiratory compromise and death. Further increased risk has been observed in the postoperative period. The aim of this study was to assess the impact of COVID-19 infection on the complication and mortality rates of NOF fracture patients.

Methods

All NOF fracture patients presenting between March 2020 and May 2020 were included. Patients were divided into two subgroup: those with or without clinical and/or laboratory diagnosis of COVID-19. Data were collected on patient demographics, pattern of injury, complications, length of stay, and mortality.


Bone & Joint Research
Vol. 9, Issue 9 | Pages 554 - 562
1 Sep 2020
Masters J Metcalfe D Ha JS Judge A Costa ML

Aims

This study explores the reported rate of surgical site infection (SSI) after hip fracture surgery in published studies concerning patients treated in the UK.

Methods

Studies were included if they reported on SSI after any type of surgical treatment for hip fracture. Each study required a minimum of 30 days follow-up and 100 patients. Meta-analysis was undertaken using a random effects model. Heterogeneity was expressed using the I2 statistic. Risk of bias was assessed using a modified Newcastle-Ottawa Scale (NOS) system.


Bone & Joint Open
Vol. 1, Issue 8 | Pages 500 - 507
18 Aug 2020
Cheruvu MS Bhachu DS Mulrain J Resool S Cool P Ford DJ Singh RA

Aims

Our rural orthopaedic service has undergone service restructure during the COVID-19 pandemic in order to sustain hip fracture care. All adult trauma care has been centralised to the Royal Shrewsbury Hospital for assessment and medical input, before transferring those requiring operative intervention to the Robert Jones and Agnes Hunt Orthopaedic Hospital. We aim to review the impact of COVID-19 on hip fracture workload and service changes upon management of hip fractures.

Methods

We reviewed our prospectively maintained trust database and National Hip Fracture Database records for the months of March and April between the years 2016 and 2020. Our assessment included fracture pattern (intrascapular vs extracapsular hip fracture), treatment intervention, length of stay and mortality.


Bone & Joint Open
Vol. 1, Issue 8 | Pages 443 - 449
1 Aug 2020
Narula S Lawless A D’Alessandro P Jones CW Yates P Seymour H

Aims

A proximal femur fracture (PFF) is a common orthopaedic presentation, with an incidence of over 25,000 cases reported in the Australian and New Zealand Hip Fracture Registry (ANZHFR) in 2018. Hip fractures are known to have high mortality. The purpose of this study was to determine the utility of the Clinical Frailty Scale (CFS) in predicting 30-day and one-year mortality after a PFF in older patients.

Methods

A retrospective review of all fragility hip fractures who met the inclusion/exclusion criteria of the ANZHFR between 2017 and 2018 was undertaken at a single large volume tertiary hospital. There were 509 patients included in the study with one-year follow-up obtained in 502 cases. The CFS was applied retrospectively to patients according to their documented pre-morbid function and patients were stratified into five groups according to their frailty score. The groups were compared using t-test, analysis of variance (ANOVA), and the chi-squared test. The discriminative ability of the CFS to predict mortality was then compared with American Society of Anaesthesiologists (ASA) classification and the patient’s chronological age.


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1292 - 1299
1 Oct 2019
Masters J Metcalfe D Parsons NR Achten J Griffin XL Costa ML

Aims

This study explores data quality in operation type and fracture classification recorded as part of a large research study and a national audit with an independent review.

Patients and Methods

At 17 centres, an expert surgeon reviewed a randomly selected subset of cases from their centre with regard to fracture classification using the AO system and type of operation performed. Agreement for these variables was then compared with the data collected during conduct of the World Hip Trauma Evaluation (WHiTE) cohort study. Both types of surgery and fracture classification were collapsed to identify the level of detail of reporting that achieved meaningful agreement. In the National Hip Fracture Database (NHFD), the types of operation and fracture classification were explored to identify the proportion of “highly improbable” combinations.


Bone & Joint Research
Vol. 8, Issue 7 | Pages 313 - 322
1 Jul 2019
Law GW Wong YR Yew AK Choh ACT Koh JSB Howe TS

Objectives

The paradoxical migration of the femoral neck element (FNE) superomedially against gravity, with respect to the intramedullary component of the cephalomedullary device, is a poorly understood phenomenon increasingly seen in the management of pertrochanteric hip fractures with the intramedullary nail. The aim of this study was to investigate the role of bidirectional loading on the medial migration phenomenon, based on unique wear patterns seen on scanning electron microscopy of retrieved implants suggestive of FNE toggling.

Methods

A total of 18 synthetic femurs (Sawbones, Vashon Island, Washington) with comminuted pertrochanteric fractures were divided into three groups (n = 6 per group). Fracture fixation was performed using the Proximal Femoral Nail Antirotation (PFNA) implant (Synthes, Oberdorf, Switzerland; n = 6). Group 1 was subjected to unidirectional compression loading (600 N), with an elastomer (70A durometer) replacing loose fracture fragments to simulate surrounding soft-tissue tensioning. Group 2 was subjected to bidirectional loading (600 N compression loading, 120 N tensile loading), also with the elastomer replacing loose fracture fragments. Group 3 was subjected to bidirectional loading (600 N compression loading, 120 N tensile loading) without the elastomer. All constructs were tested at 2 Hz for 5000 cycles or until cut-out occurred. The medial migration distance (MMD) was recorded at the end of the testing cycles.


Bone & Joint 360
Vol. 8, Issue 3 | Pages 23 - 26
1 Jun 2019


The Bone & Joint Journal
Vol. 101-B, Issue 6_Supple_B | Pages 84 - 90
1 Jun 2019
Charette RS Sloan M Lee G

Aims

Total hip arthroplasty (THA) is gaining popularity as a treatment for displaced femoral neck fractures (FNFs), especially in physiologically younger patients. While THA for osteoarthritis (OA) has demonstrated low complication rates and increased quality of life, results of THA for acute FNF are not as clear. Currently, a THA performed for FNF is included in an institutional arthroplasty bundle without adequate risk adjustment, potentially placing centres participating in fracture care at financial disadvantage. The purpose of this study is to report on perioperative complication rates after THA for FNF compared with elective THA performed for OA of the hip.

Patients and Methods

The American College of Surgeons National Surgical Quality Improvement Program (ACS NSQIP) database between 2008 and 2016 was queried. Patients were identified using the THA Current Procedural Terminology (CPT) code and divided into groups by diagnosis: OA in one and FNF in another. Univariate statistics were performed. Continuous variables were compared between groups using Student’s t-test, and the chi-squared test was used to compare categorical variables. Multivariate and propensity-matched logistic regression analyses were performed to control for risk factors of interest.


Bone & Joint 360
Vol. 7, Issue 6 | Pages 31 - 33
1 Dec 2018


The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 559 - 565
1 May 2018
Bartlett JD Lawrence JE Stewart ME Nakano N Khanduja V

Aims

The aim of this study was to assess the current evidence relating to the benefits of virtual reality (VR) simulation in orthopaedic surgical training, and to identify areas of future research.

Materials and Methods

A literature search using the MEDLINE, Embase, and Google Scholar databases was performed. The results’ titles, abstracts, and references were examined for relevance.


Bone & Joint 360
Vol. 5, Issue 2 | Pages 26 - 28
1 Apr 2016


The Bone & Joint Journal
Vol. 96-B, Issue 8 | Pages 1029 - 1034
1 Aug 2014
Kashigar A Vincent A Gunton MJ Backstein D Safir O Kuzyk PRT

The purpose of this study was to identify factors that predict implant cut-out after cephalomedullary nailing of intertrochanteric and subtrochanteric hip fractures, and to test the significance of calcar referenced tip-apex distance (CalTAD) as a predictor for cut-out.

We retrospectively reviewed 170 consecutive fractures that had undergone cephalomedullary nailing. Of these, 77 met the inclusion criteria of a non-pathological fracture with a minimum of 80 days radiological follow-up (mean 408 days; 81 days to 4.9 years). The overall cut-out rate was 13% (10/77).

The significant parameters in the univariate analysis were tip-apex distance (TAD) (p <  0.001), CalTAD (p = 0.001), cervical angle difference (p = 0.004), and lag screw placement in the anteroposterior (AP) view (Parker’s ratio index) (p = 0.003). Non-significant parameters were age (p = 0.325), gender (p = 1.000), fracture side (p = 0.507), fracture type (AO classification) (p = 0.381), Singh Osteoporosis Index (p = 0.575), lag screw placement in the lateral view (p = 0.123), and reduction quality (modified Baumgaertner’s method) (p = 0.575). In the multivariate analysis, CalTAD was the only significant measurement (p = 0.001). CalTAD had almost perfect inter-observer reliability (interclass correlation coefficient (ICC) 0.901).

Our data provide the first reported clinical evidence that CalTAD is a predictor of cut-out. The finding of CalTAD as the only significant parameter in the multivariate analysis, along with the univariate significance of Parker’s ratio index in the AP view, suggest that inferior placement of the lag screw is preferable to reduce the rate of cut-out.

Cite this article: Bone Joint J 2014; 96-B:1029–34.


Bone & Joint 360
Vol. 6, Issue 4 | Pages 25 - 29
1 Aug 2017


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 7 - 10
1 Nov 2013
Petrie J Sassoon A Haidukewych GJ

Most hip fractures treated with modern internal fixation techniques will heal. However, failures occasionally occur and require revision procedures. Salvage strategies employed during revision are based on whether the fixation failure occurs in the femoral neck, or in the intertrochanteric region. Patient age and remaining bone stock also influence decision making. For fractures in young patients, efforts are generally focused on preserving the native femoral head via osteotomies and repeat internal fixation. For failures in older patients, some kind of hip replacement is usually selected. Disuse osteopenia, deformity, bone loss, and stress-risers from previous internal fixation devices all pose technical challenges to successful reconstruction. Attention to detail is important in order to minimise complications. In the majority of cases, good outcomes have been reported for the various salvage strategies.

Cite this article: Bone Joint J 2013;95-B, Supple A:7–10.


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1216 - 1222
1 Sep 2017
Fu MC Boddapati V Gausden EB Samuel AM Russell LA Lane JM

Aims

We aimed to characterise the effect of expeditious hip fracture surgery in elderly patients within 24 hours of admission on short-term post-operative outcomes.

Patients and Methods

Patients age 65 or older that underwent surgery for closed femoral neck and intertrochanteric hip fractures were identified from the American College of Surgeons National Surgical Quality Improvement Program between 2011 and 2014. Multivariable propensity-adjusted logistic regressions were performed to determine associations between early surgery within 24 hours and post-operative complications, controlling for selection bias in patients undergoing early surgery based on observable characteristics.


Bone & Joint Research
Vol. 6, Issue 4 | Pages 204 - 207
1 Apr 2017
Fernandez MA Aquilina A Achten J Parsons N Costa ML Griffin XL

Objectives

The Sliding Hip Screw (SHS) is commonly used to treat trochanteric hip fractures. Fixation failure is a devastating complication requiring complex revision surgery. One mode of fixation failure is lag screw cut-out which is greatest in unstable fracture patterns and when the tip-apex distance of the lag screw is > 25 mm. The X-Bolt Dynamic Hip Plating System (X-Bolt Orthopaedics, Dublin, Ireland) is a new device which aims to reduce this risk of cut-out. However, some surgeons have reported difficulty minimising the tip-apex distance with subsequent concerns that this may lead to an increased risk of cut-out.

Patients and Methods

We measured the tip-apex distance from the intra-operative radiographs of 93 unstable trochanteric hip fractures enrolled in a randomised controlled trial (Warwick Hip Trauma Evaluation, WHiTE One trial). Participants were treated with either the sliding hip screw or the X-Bolt dynamic hip plating system. We also recorded the incidence of cut-out in both groups, at a median follow-up time of 17 months.


The Bone & Joint Journal
Vol. 97-B, Issue 9 | Pages 1279 - 1283
1 Sep 2015
Mahale YJ Aga N

In this retrospective observational cohort study, we describe 17 patients out of 1775 treated for various fractures who developed mycobacterium tuberculosis (MTB) infection after surgery. The cohort comprised 15 men and two women with a mean age of 40 years (24 to 70). A total of ten fractures were open and seven were closed. Of these, seven patients underwent intramedullary nailing of a fracture of the long bone, seven had fractures fixed with plates, two with Kirschner-wires and screws, and one had a hemiarthroplasty of the hip with an Austin Moore prosthesis. All patients were followed-up for two years. In all patients, the infection resolved, and in 14 the fractures united. Nonunion was seen in two patients one of whom underwent two-stage total hip arthroplasty (THA) and the other patient was treated using excision arthoplasty. Another patient was treated using two-stage THA. With only sporadic case reports in the literature, MTB infection is rarely clinically suspected, even in underdeveloped and developing countries, where pulmonary and other forms of TB are endemic. In developed countries there is also an increased incidence among immunocompromised patients. In this paper we discuss the pathogenesis and incidence of MTB infection after surgical management of fractures and suggest protocols for early diagnosis and management.

Cite this article: Bone Joint J 2015;97-B:1279–83.


Bone & Joint Research
Vol. 6, Issue 3 | Pages 144 - 153
1 Mar 2017
Kharwadkar N Mayne B Lawrence JE Khanduja V

Objectives

Bisphosphonates are widely used as first-line treatment for primary and secondary prevention of fragility fractures. Whilst they have proved effective in this role, there is growing concern over their long-term use, with much evidence linking bisphosphonate-related suppression of bone remodelling to an increased risk of atypical subtrochanteric fractures of the femur (AFFs). The objective of this article is to review this evidence, while presenting the current available strategies for the management of AFFs.

Methods

We present an evaluation of current literature relating to the pathogenesis and treatment of AFFs in the context of bisphosphonate use.


The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 175 - 183
1 Feb 2017
Morita D Hasegawa Y Okura T Osawa Y Ishiguro N

Aims

Transtrochanteric rotational osteotomy (TRO) is performed for young patients with non-traumatic osteonecrosis of the femoral head (ONFH) to preserve the hip. We aimed to investigate the long-term outcomes and the risk factors for failure 15 years after this procedure.

Patients and Methods

This study included 95 patients (111 hips) with a mean age of 40 years (21 to 64) who underwent TRO for ONFH. The mean follow-up was 18.2 years (3 to 26). Kaplan–Meier survivorship analyses were performed with conversion to total hip arthroplasty (THA) and radiological failure due to secondary collapse of the femoral head or osteoarthritic changes as the endpoint. Multivariate analyses were performed to assess risk factors for each outcome.


Bone & Joint 360
Vol. 5, Issue 5 | Pages 27 - 29
1 Oct 2016


Bone & Joint 360
Vol. 5, Issue 3 | Pages 26 - 28
1 Jun 2016


Bone & Joint 360
Vol. 1, Issue 1 | Pages 10 - 12
1 Feb 2012


Bone & Joint Research
Vol. 1, Issue 4 | Pages 50 - 55
1 Apr 2012
O’Neill F Condon F McGloughlin T Lenehan B Coffey C Walsh M

Introduction

The objective of this study was to determine if a synthetic bone substitute would provide results similar to bone from osteoporotic femoral heads during in vitro testing with orthopaedic implants. If the synthetic material could produce results similar to those of the osteoporotic bone, it could reduce or eliminate the need for testing of implants on bone.

Methods

Pushout studies were performed with the dynamic hip screw (DHS) and the DHS Blade in both cadaveric femoral heads and artificial bone substitutes in the form of polyurethane foam blocks of different density. The pushout studies were performed as a means of comparing the force displacement curves produced by each implant within each material.


The Bone & Joint Journal
Vol. 95-B, Issue 9 | Pages 1250 - 1254
1 Sep 2013
Lakstein D Hendel D Haimovich Y Feldbrin Z

The purpose of this study was to identify changing trends in the pattern of distribution of the type and demographics of fractures of the hip in the elderly between 2001 and 2010. A retrospective cross-sectional comparison was conducted between 179 fractures of the hip treated in 2001, 357 treated in 2006 and 454 treated in 2010. Patients aged < 60 years and those with pathological and peri-prosthetic fractures were excluded. Fractures were classified as stable extracapsular, unstable extracapsular or intracapsular fractures.

The mean age of the 179 patients (132 women (73.7%)) treated in 2001 was 80.8 years (60 to 96), 81.8 years (61 to 101) in the 357 patients (251 women (70.3%)) treated in 2006 and 82.0 years (61 to 102) in the 454 patients (321 women (70.1%)) treated in 2010 (p = 0.17). There was no difference in the gender distribution between the three study years (p = 0.68).

The main finding was a steep rise in the proportion of unstable peritrochanteric fractures. The proportion of unstable extracapsular fractures was 32% (n = 57) in 2001, 35% (n = 125) in 2006 and 45% (n = 204) in 2010 (p < 0.001). This increase was not significant in patients aged between 60 and 69 years (p = 0.84), marginally significant in those aged between 70 and 79 years (p = 0.04) and very significant in those aged > 80 years (p < 0.001). The proportion of intracapsular fractures did not change (p = 0.94).

At present, we face not only an increasing number of fractures of the hip, but more demanding and complex fractures in older patients than a decade ago. This study does not provide an explanation for this change.

Cite this article: Bone Joint J 2013;95-B:1250–4.


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1144 - 1148
1 Aug 2013
Sternheim A Saidi K Lochab J O’Donnell PW Eward WC Griffin A Wunder JS Ferguson P

We investigated the clinical outcome of internal fixation for pathological fracture of the femur after primary excision of a soft-tissue sarcoma that had been treated with adjuvant radiotherapy.

A review of our database identified 22 radiation-induced fractures of the femur in 22 patients (seven men, 15 women). We noted the mechanism of injury, fracture pattern and any complications after internal fixation, including nonunion, hardware failure, secondary fracture or deep infection.

The mean age of the patients at primary excision of the tumour was 58.3 years (39 to 86). The mean time from primary excision to fracture was 73.2 months (2 to 195). The mean follow-up after fracture fixation was 65.9 months (12 to 205). Complications occurred in 19 patients (86%). Nonunion developed in 18 patients (82%), of whom 11 had a radiological nonunion at 12 months, five a nonunion and hardware failure and two an infected nonunion. One patient developed a second radiation-associated fracture of the femur after internal fixation and union of the initial fracture. A total of 13 patients (59%) underwent 24 revision operations.

Internal fixation of a pathological fracture of the femur after radiotherapy for a soft-tissue sarcoma has an extremely high rate of complication and requires specialist attention.

Cite this article: Bone Joint J 2013;95-B:1144–8.


Bone & Joint 360
Vol. 2, Issue 1 | Pages 42 - 43
1 Feb 2013
Moran CG


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 12 | Pages 1653 - 1657
1 Dec 2005
Wedin R Bauer HCF

We report positive and negative factors associated with the most commonly-used methods of reconstruction after pathological fracture of the proximal femur. The study was based on 142 patients treated surgically for 146 metastatic lesions between 1996 and 2003. The local rate of failure was 10.3% (15 of 146). Of 37 operations involving osteosynthetic devices, six failed (16.2%) compared with nine (8.3%) in 109 operations involving endoprostheses. Of nine cases of prosthetic failure, four were due to periprosthetic fractures and three to recurrent dislocation. In the osteosynthesis group, three (13.6%) of 22 reconstruction nails failed. The two-year risk of re-operation after any type of osteosynthesis was 0.35 compared with 0.18 after any type of endoprosthetic reconstruction (p = 0.07). Endoprosthetic reconstructions are preferable to the use of reconstruction nails and other osteosynthetic devices for the treatment of metastatic lesions in the proximal third of the femur.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 26 - 31
1 Nov 2012
Mayle RE Della Valle CJ

The purpose of this paper is to discuss the risk factors, prevention strategies, classification, and treatment of intra-operative femur fractures sustained during primary and revision total hip arthroplasty.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 969 - 973
1 Jul 2012
Iwata T Nozawa S Dohjima T Yamamoto T Ishimaru D Tsugita M Maeda M Shimizu K

A delay in establishing the diagnosis of an occult fracture of the hip that remains unrecognised after plain radiography can result in more complex treatment such as an arthroplasty being required. This might be avoided by earlier diagnosis using MRI. The aim of this study was to investigate the best MR imaging sequence for diagnosing such fractures. From a consecutive cohort of 771 patients admitted between 2003 and 2011 with a clinically suspected fracture of the hip, we retrospectively reviewed the MRI scans of the 35 patients who had no evidence of a fracture on their plain radiographs. In eight of these patients MR scanning excluded a fracture but the remaining 27 patients had an abnormal scan: one with a fracture of the pubic ramus, and in the other 26 a T1-weighted coronal MRI showed a hip fracture with 100% sensitivity. T2-weighted imaging was undertaken in 25 patients, in whom the diagnosis could not be established with this scanning sequence alone, giving a sensitivity of 84.0% for T2-weighted imaging.

If there is a clinical suspicion of a hip fracture with normal radiographs, T1-weighted coronal MRI is the best sequence of images for identifying a fracture.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 10 | Pages 1300 - 1302
1 Oct 2011
Stafford GH Villar RN

Femoroacetabular impingement is a well-documented cause of hip pain. There is, however, increasing evidence for the presence of a previously unrecognised impingement-type condition around the hip – ischiofemoral impingement. This is caused by abnormal contact between the lesser trochanter of the femur and the ischium, and presents as atypical groin and/or posterior buttock pain. The symptoms are gradual in onset and may be similar to those of iliopsoas tendonitis, hamstring injury or bursitis. The presence of ischiofemoral impingement may be indicated by pain caused by a combination of hip extension, adduction and external rotation. Magnetic resonance imaging demonstrates inflammation and oedema in the ischiofemoral space and quadratus femoris, and is distinct from an acute tear. To date this has only appeared in the specialist orthopaedic literature as a problem that has developed after total hip replacement, not in the unreplaced joint.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 5 | Pages 596 - 602
1 May 2012
Hansson G Nathorst-Westfelt J

In the majority of patients with slipped upper femoral epiphysis only one hip is involved at primary diagnosis. However, the contralateral hip often becomes involved over time. There are no reliable factors predicting a contralateral slip. Whether or not the contralateral hip should undergo prophylactic fixation is a matter of controversy. We present a number of essential points that have to be considered both when choosing to fix the contralateral hip prophylactically as well as when refraining from surgery and instead following the patients with repeat radiographs.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1135 - 1142
1 Aug 2012
Derikx LC van Aken JB Janssen D Snyers A van der Linden YM Verdonschot N Tanck E

Previously, we showed that case-specific non-linear finite element (FE) models are better at predicting the load to failure of metastatic femora than experienced clinicians. In this study we improved our FE modelling and increased the number of femora and characteristics of the lesions. We retested the robustness of the FE predictions and assessed why clinicians have difficulty in estimating the load to failure of metastatic femora. A total of 20 femora with and without artificial metastases were mechanically loaded until failure. These experiments were simulated using case-specific FE models. Six clinicians ranked the femora on load to failure and reported their ranking strategies. The experimental load to failure for intact and metastatic femora was well predicted by the FE models (R2 = 0.90 and R2 = 0.93, respectively). Ranking metastatic femora on load to failure was well performed by the FE models (τ = 0.87), but not by the clinicians (0.11 < τ < 0.42). Both the FE models and the clinicians allowed for the characteristics of the lesions, but only the FE models incorporated the initial bone strength, which is essential for accurately predicting the risk of fracture. Accurate prediction of the risk of fracture should be made possible for clinicians by further developing FE models.


Bone & Joint Research
Vol. 1, Issue 6 | Pages 104 - 110
1 Jun 2012
Swinteck BJ Phan DL Jani J Owen JR Wayne JS Mounasamy V

Objectives

The use of two implants to manage concomitant ipsilateral femoral shaft and proximal femoral fractures has been indicated, but no studies address the relationship of dynamic hip screw (DHS) side plate screws and the intramedullary nail where failure might occur after union. This study compares different implant configurations in order to investigate bridging the gap between the distal DHS and tip of the intramedullary nail.

Methods

A total of 29 left synthetic femora were tested in three groups: 1) gapped short nail (GSN); 2) unicortical short nail (USN), differing from GSN by the use of two unicortical bridging screws; and 3) bicortical long nail (BLN), with two angled bicortical and one unicortical bridging screws. With these findings, five matched-pairs of cadaveric femora were tested in two groups: 1) unicortical long nail (ULN), with a longer nail than USN and three bridging unicortical screws; and 2) BLN. Specimens were axially loaded to 22.7 kg (50 lb), and internally rotated 90°/sec until failure.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 9 | Pages 1192 - 1194
1 Sep 2010
Petrie A

In comparing or assessing methods of treatment it is vital that the appropriate number of patients is selected in order to ensure that the conclusions drawn are statistically viable. This annotation describes the relevance of a statistical power analysis in the context of hypothesis testing to the determination of the optimal sample size of a study. The power of the test indicates how likely it is that the test will correctly produce a statistically significant result.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 11 | Pages 1533 - 1534
1 Nov 2008


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 5 | Pages 706 - 706
1 May 2007


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 157 - 166
1 Nov 2012
Rosenberg AG Berend ME Berry DJ Della Valle CJ MacDonald SJ Minas T

This conversation represents an attempt by several arthroplasty surgeons to critique several abstracts presented over the last year as well as to use them as a jumping off point for trying to figure out where they fit in into our current understanding of multiple issues in modern hip and knee arthroplasty.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1422 - 1428
1 Oct 2010
van den Bekerom MPJ Hilverdink EF Sierevelt IN Reuling EMBP Schnater JM Bonke H Goslings JC van Dijk CN Raaymakers ELFB

The aim of this study was to analyse the functional outcome after a displaced intracapsular fracture of the femoral neck in active patients aged over 70 years without osteoarthritis or rheumatoid arthritis of the hip, randomised to receive either a hemiarthroplasty or a total hip replacement (THR). We studied 252 patients of whom 47 (19%) were men, with a mean age of 81.1 years (70.2 to 95.6). They were randomly allocated to be treated with either a cemented hemiarthroplasty (137 patients) or cemented THR (115 patients). At one- and five-year follow-up no differences were observed in the modified Harris hip score, revision rate of the prosthesis, local and general complications, or mortality. The intra-operative blood loss was lower in the hemiarthroplasty group (7% > 500 ml) than in the THR group (26% > 500 ml) and the duration of surgery was longer in the THR group (28% > 1.5 hours versus 12% > 1.5 hours). There were no dislocations of any bipolar hemiarthroplasty and eight dislocations of a THR during follow-up.

Because of a higher intra-operative blood loss (p < 0.001), an increased duration of the operation (p < 0.001) and a higher number of early and late dislocations (p = 0.002), we do not recommend THR as the treatment of choice in patients aged ≥ 70 years with a fracture of the femoral neck in the absence of advanced radiological osteoarthritis or rheumatoid arthritis of the hip.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 7 | Pages 1006 - 1012
1 Jul 2010
Davids JR Hydorn C Dillingham C Hardin JW Pugh LI

We have reviewed our experience of the removal of deep extremity orthopaedic implants in children to establish the nature, rate and risk of complications associated with this procedure. A retrospective review was performed of 801 children who had 1223 implants inserted and subsequently removed over a period of 17 years. Bivariate analysis of possible predictors including clinical factors, complications associated with implant insertion and indications for removal and the complications encountered at removal was performed. A logistical regression model was then constructed using those predictors which were significantly associated with surgical complications from the bivariate analyses. Odds ratios estimated in the logistical regression models were converted to risk ratios.

The overall rate of complications after removal of the implant was 12.5% (100 complications in 801 patients), with 48 (6.0%) major and 52 (6.5%) minor. Children with a complication after insertion of the initial implant or with a non-elective indication for removal, a neuromuscular disease associated with a seizure disorder or a neuromuscular disease in those unable to walk, had a significantly greater chance of having a major complication after removal of the implant. Children with all four of these predictors were 14.6 times more likely to have a major complication.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 9 | Pages 1187 - 1191
1 Sep 2005
Pitts D Rowley DI Sher JL


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 461 - 466
1 Apr 2007
Tsuboi M Hasegawa Y Suzuki S Wingstrand H Thorngren K

We studied prospectively the change over ten years in mortality, walking ability and place of residence after a hip fracture in 753 patients in Japan. We compared the deaths observed in these patients with those expected in the general population, matched for age, gender and calender year at the time of fracture. The survival rate decreased dramatically for two years after the event and the mortality risk remained higher for ten years. This risk was approximately double that of the general population, even at ten years after fracture. The risk was higher, and remained so for longer, in younger rather than in older patients.

The proportion of patients who were able to walk outdoors alone, with or without an assistive device, was 68% (514) before fracture. This decreased to 56% (340) by one year after and remained stable at approximately 63% (125) until ten years. The proportion of patients living in their own home was 84% (629) before fracture, 81% (491) one year later, and then remained stable at approximately 86% (171) until ten years after the event.