Aims. Magnetically controlled growing
The results and complications of the use of Bailey-Dubow extensible
Aims. The Fassier Duval (FD)
Aims. This study examined whether systemic administration of melatonin would have different effects on osseointegration in ovariectomized (OVX) rats, depending on whether this was administered during the day or night. Methods. In this study, a titanium
Aims. To investigate metallosis in patients with magnetically controlled growing
Aims. Magnetically controlled growing
Aims. To report the mid-term results of a modified self-growing
Aims. The aim of this study was to compare the clinical and radiological outcomes of patients with early-onset scoliosis (EOS), who had undergone spinal fusion after distraction-based spinal growth modulation using either traditional growing
Aims. One method of femoral head preservation following avascular necrosis
(AVN) is core decompression and insertion of a tantalum
The treatment of infected nonunions is difficult.
Antibiotic cement-coated (ACC)
Aims. The aim of this study was to compare the outcomes of surgery
using growing
Aims. The primary aim of this study was to evaluate the performance
and safety of magnetically controlled growth
We report the results of using 83 expanding intramedullary
Five patients with Boyd type II congenital pseudarthrosis of the tibia underwent excision of the pseudarthrosis and double onlay bone grafting. Stability was maintained by extending intramedullary
We investigated the fracture-free survival of long bones stabilised by a telescopic intramedullary
This paper describes the design, development and early surgical experience with a stereotactic device to allow closed retrieval and interchange of intramedullary
Intramedullary infection in long bones represents
a complex clinical challenge, with an increasing incidence due to the
increasing use of intramedullary fixation. We report a prospective
case series using an intramedullary reaming device, the Reamer–Irrigator–Aspirator
(RIA) system, in association with antibiotic cement
Three cases of severe osteogenesis imperfecta are reported. Each was treated by closed intramedullary
Aims. Magnetically controlled growing
In a prospective trial, biodegradable polyglycolic acid
The Sheffield Expanding Intramedullary
Intramedullary
Adolescent idiopathic scoliosis in 152 patients was treated by Luque L-rod instrumentation and early mobilisation without external support. This series was compared with a matched group of 156 patients treated by Harrington instrumentation and immobilised in an underarm jacket for nine months. All the operations in both groups were performed by one surgeon and the patients were followed prospectively for more than two years. Correction of the scoliosis in the frontal plane was similar in both groups. However, the normal sagittal contour was better maintained with Luque
Aims. Congenital pseudarthrosis of the tibia (CPT) has traditionally been a difficult condition to treat, with high complication rates, including nonunion, refractures, malalignment, and leg length discrepancy. Surgical approaches to treatment of CPT include intramedullary
Abstract. MAGnetic Expansion Control (MAGEC)
The April 2024 Spine Roundup. 360. looks at: Lengthening behaviour of magnetically controlled growing
Aims. This study intended to investigate the effect of vericiguat (VIT) on titanium
The April 2023 Children’s orthopaedics Roundup. 360. looks at: Can you treat type IIA supracondylar humerus fractures conservatively?; Bone bruising and anterior cruciate ligament injury in paediatrics; Participation and motor abilities after treatment with the Ponseti method; Does fellowship training help with paediatric supracondylar fractures?; Supracondylar elbow fracture management (Supra Man): a national trainee collaborative evaluation of practice; Magnetically controlled growing
Aims. The aim of this study was to investigate the incidence and characteristics of instrumentation failure (IF) after total en bloc spondylectomy (TES), and to analyze risk factors for IF. Methods. The medical records from 136 patients (65 male, 71 female) with a mean age of 52.7 years (14 to 80) who underwent TES were retrospectively reviewed. The mean follow-up period was 101 months (36 to 232). Analyzed factors included incidence of IF, age, sex, BMI, history of chemotherapy or radiotherapy, tumour histology (primary or metastasis; benign or malignant), surgical approach (posterior or combined), tumour location (thoracic or lumbar; junctional or non-junctional), number of resected vertebrae (single or multilevel), anterior resection line (disc-to-disc or intravertebra), type of bone graft (autograft or frozen autograft), cage subsidence (CS), and local alignment (LA). A survival analysis of the instrumentation was performed, and relationships between IF and other factors were investigated using the Cox regression model. Results. A total of 44 patients (32.4%) developed IF at a median of 31 months (interquartile range 23 to 74) following TES. Most IFs were
Aims. We present a case series of five patients who had revision surgery
following magnetic controlled growing
Aims. The aim of this study was to develop a single-layer hybrid organic-inorganic sol-gel coating that is capable of a controlled antibiotic release for cementless hydroxyapatite (HA)-coated titanium orthopaedic prostheses. Methods. Coatings containing gentamicin at a concentration of 1.25% weight/volume (wt/vol), similar to that found in commercially available antibiotic-loaded bone cement, were prepared and tested in the laboratory for: kinetics of antibiotic release; activity against planktonic and biofilm bacterial cultures; biocompatibility with cultured mammalian cells; and physical bonding to the material (n = 3 in all tests). The sol-gel coatings and controls were then tested in vivo in a small animal healing model (four materials tested; n = 6 per material), and applied to the surface of commercially pure HA-coated titanium
Conventional growing
Aims. Severe spinal deformity in growing patients often requires surgical management. We describe the incidence of spinal deformity surgery in a National Health Service. Methods. Descriptive study of prospectively collected data. Clinical data of all patients undergoing surgery for spinal deformity between 2005 and 2018 was collected, compared to the demographics of the national population, and analyzed by underlying aetiology. Results. Our cohort comprised 2,205 patients; this represents an incidence of 14 per 100,000 individuals among the national population aged between zero and 18 years. There was an increase in mean annual incidence of spinal deformity surgery across the study period from 9.6 (7.2 to 11.7) per 100,000 individuals in 2005 to 2008, to 17.9 (16.1 to 21.5) per 100,000 individuals in 2015 to 2018 (p = 0.001). The most common cause of spinal deformity was idiopathic scoliosis accounting for 56.7% of patients. There was an increase in mean incidence of surgery for adolescent idiopathic scoliosis (AIS) (from 4.4 (3.1 to 5.9) to 9.8 (9.1 to 10.8) per 100,000 individuals; p < 0.001), juvenile idiopathic scoliosis (JIS) (from 0.2 (0.1 to 0.4) to one (0.5 to 1.3) per 100,000 individuals; p = 0.009), syndromic scoliosis (from 0.7 (0.3 to 0.9) to 1.7 (1.2 to 2.4) per 100,000 individuals; p = 0.044), Scheuermann’s kyphosis (SK) (from 0.2 (0 to 0.7) to 1.2 (1.1 to 1.3) per 100,000 individuals; p = 0.001), and scoliosis with intraspinal abnormalities (from 0.04 (0 to 0.08) to 0.6 (0.5 to 0.8) per 100,000 individuals; p = 0.008) across the study period. There was an increase in mean number of posterior spinal fusions performed each year from mean 84.5 (51 to 108) in 2005 to 2008 to 182.5 (170 to 210) in 2015 to 2018 (p < 0.001) and a reduction in mean number of growing
Aims. Anchorage of pedicle screw
Aims. We undertook a prospective non-randomised radiological study
to evaluate the preliminary results of using magnetically-controlled
growing
Aims. The aim of this retrospective study was to compare the correction achieved using a convex pedicle screw technique and a low implant density achieved using periapical concave-sided screws and a high implant density. We hypothesized that there would be no difference in outcome between the two techniques. Methods. We retrospectively analyzed a series of 51 patients with a thoracic adolescent idiopathic scoliosis. There were 26 patients in the convex pedicle screw group who had screws implanted periapically (Group 2) and a control group of 25 patients with bilateral pedicle screws (Group 1). The patients’ charts were reviewed and pre- and postoperative radiographs evaluated. Postoperative patient-reported outcome measures (PROMs) were recorded. Results. The number of implants (14.5 vs 17.1) and the implant density (1.5 vs 1.9) were significantly lower in Group 2 (p < 0.001). Operating time was 27 minutes shorter in Group 2 than in Group 1, with a mean of 217 minutes (SD 50.5; 120 to 346). The duration of surgery per instrumented vertebra was reduced by 19% in Group 2 (p = 0.011). No statistical difference was found in the postoperative Cobb angle, vertebral rotation, the relative correction achieved, or postoperative PROMs. Conclusion. Despite a lower implant density and achieving correction through a convex
Aims. The value of core decompression (CD) in the treatment of osteonecrosis of the femoral head (ONFH) remains controversial. We conducted a systematic review and meta-analysis to evaluate whether CD combined with other treatments could improve the clinical and radiological outcomes of ONFH patients compared with CD alone. Methods. We searched the PubMed, Embase, Web of Science, and Cochrane Library databases until June 2020. All randomized controlled trials (RCTs) and clinical controlled trials (CCTs) comparing CD alone and CD combined with other measures (CD + cell therapy, CD + bone grafting, CD + porous tantalum
Aims. Spinal deformity surgery carries the risk of neurological injury. Neurophysiological monitoring allows early identification of intraoperative cord injury which enables early intervention resulting in a better prognosis. Although multimodal monitoring is the ideal, resource constraints make surgeon-directed intraoperative transcranial motor evoked potential (TcMEP) monitoring a useful compromise. Our experience using surgeon-directed TcMEP is presented in terms of viability, safety, and efficacy. Methods. We carried out a retrospective review of a single surgeon’s prospectively maintained database of cases in which TcMEP monitoring had been used between 2010 and 2017. The upper limbs were used as the control. A true alert was recorded when there was a 50% or more loss of amplitude from the lower limbs with maintained upper limb signals. Patients with true alerts were identified and their case history analyzed. Results. Of the 299 cases reviewed, 279 (93.3%) had acceptable traces throughout and awoke with normal clinical neurological function. No patient with normal traces had a postoperative clinical neurological deficit. True alerts occurred in 20 cases (6.7%). The diagnoses of the alert group included nine cases of adolescent idiopathic scoliosis (AIS) (45%) and six of congenital scoliosis (30%). The incidence of deterioration based on diagnosis was 9/153 (6%) for AIS, 6/30 (20%) for congenital scoliosis, and 2/16 (12.5%) for spinal tuberculosis. Deterioration was much more common in congenital scoliosis than in AIS (p = 0.020). Overall, 65% of alerts occurred during
Objectives. Previous studies have evidenced cement-in-cement techniques as reliable in revision arthroplasty. Commonly, the original cement mantle is reshaped, aiding accurate placement of the new stem. Ultrasonic devices selectively remove cement, preserve host bone, and have lower cortical perforation rates than other techniques. As far as the authors are aware, the impact of ultrasonic devices on final cement-in-cement bonds has not been investigated. This study assessed the impact of cement removal using the Orthosonics System for Cemented Arthroplasty Revision (OSCAR; Orthosonics) on final cement-in-cement bonds. Methods. A total of 24 specimens were manufactured by pouring cement (Simplex P Bone Cement; Stryker) into stainless steel moulds, with a central
The management of spinal deformity in children
with univentricular cardiac pathology poses significant challenges to
the surgical and anaesthetic teams. To date, only posterior instrumented
fusion techniques have been used in these children and these are
associated with a high rate of complications. We reviewed our experience
of both growing
We reviewed 212 consecutive patients with adolescent
idiopathic scoliosis who underwent posterior spinal arthrodesis
using all pedicle screw instrumentation in terms of clinical, radiological
and Scoliosis Research Society (SRS)-22 outcomes. In Group 1 (51
patients), the correction was performed over two
Aims. Significant correction of an adolescent idiopathic scoliosis in the coronal plane through a posterior approach is associated with hypokyphosis. Factors such as the magnitude of the preoperative coronal curve, the use of hooks, number of levels fused, preoperative kyphosis, screw density, and
Aims. The aim of this study was to compare the surgical and quality-of-life outcomes of children with skeletal dysplasia to those in children with idiopathic early-onset scoliosis (EOS) undergoing growth-friendly management. Patients and Methods. A retrospective review of two prospective multicentre EOS databases identified 33 children with skeletal dysplasia and EOS (major curve ≥ 30°) who were treated with growth-friendly instrumentation at younger than ten years of age, had a minimum two years of postoperative follow-up, and had undergone three or more lengthening procedures. From the same registries, 33 matched controls with idiopathic EOS were identified. A total of 20 children in both groups were treated with growing
Pathological fractures due to metastasis with destruction of the acetabulum and central dislocation of the hip present a difficult surgical challenge. We describe a series using a single technique in which a stable and long-lasting reconstruction was obtained using standard primary hip replacement implants augmented by strong, fully-threaded steel
Aims. The aim of this study was to describe the use of 3D-printed sacral endoprostheses to reconstruct the pelvic ring and re-establish spinopelvic stability after total en bloc sacrectomy (TES) and to review its outcome. Patients and Methods. We retrospectively reviewed 32 patients who underwent TES in our hospital between January 2015 and December 2017. We divided the patients into three groups on the basis of the method of reconstruction: an endoprosthesis group (n = 10); a combined reconstruction group (n = 14), who underwent non-endoprosthetic combined reconstruction, including anterior spinal column fixation; and a spinopelvic fixation (SPF) group (n = 8), who underwent only SPF. Spinopelvic stability, implant survival (IS), intraoperative haemorrhage rate, and perioperative complication rate in the endoprosthesis group were documented and compared with those of other two groups. Results. The mean overall follow-up was 22.1 months (9 to 44). In the endoprosthesis group, the mean intraoperative hemorrhage was 3530 ml (1600 to 8100). Perioperative complications occurred in two patients; both had problems with wound healing. After a mean follow-up of 17.7 months (12 to 38), 9/10 patients could walk without aids and 8/10 patients were not using analgesics. Imaging evidence of implant failure was found in three patients, all of whom had breakage of screws and/or
We reviewed the outcome of patients who had been
treated operatively for symptomatic peri-acetabular metastases and
present an algorithm to guide treatment. . The records of 81 patients who had been treated operatively for
symptomatic peri-acetabular metastases between 1987 and 2010 were
identified. There were 27 men and 54 women with a mean age of 61
years (15 to 87). The diagnosis, size of lesion, degree of pelvic
continuity, type of reconstruction, World Health Organization performance
status, survival time, pain, mobility and complications including
implant failure were recorded in each case. The overall patient survivorship at five years was 5%. The longest
lived patient survived 16 years from the date of diagnosis. The
mean survival was 23 months (<
1 to 16 years) and the median
was 15 months. At follow-up 14 patients remained alive. Two cementoplasties
failed because of local disease progression. Three Harrington
The MAGnetic Expansion Control (MAGEC) system
is used increasingly in the management of early-onset scoliosis.
Good results have been published, but there have been recent reports
identifying implant failures that may be associated with significant
metallosis surrounding the implants. This article aims to present
the current knowledge regarding the performance of this implant,
and the potential implications and strategies that may be employed
to identify and limit any problems. We urge surgeons to apply caution to patient and construct selection;
engage in prospective patient registration using a spine registry;
ensure close clinical monitoring until growth has ceased; and send
all explanted MAGEC
The aim of this study was to compare outcomes after growth-friendly treatment for early-onset scoliosis (EOS) between patients with skeletal dysplasias versus those with other syndromes. We retrospectively identified 20 patients with skeletal dysplasias and 292 with other syndromes (control group) who had completed surgical growth-friendly EOS treatment between 1 January 2000 and 31 December 2018. We compared radiological parameters, complications, and health-related quality of life (HRQoL) at mean follow-up of 8.6 years (SD 3.3) in the dysplasia group and 6.6 years (SD 2.6) in the control group.Aims
Methods
The February 2023 Trauma Roundup360 looks at: Masquelet versus bone transport in infected nonunion of tibia; Hyperbaric Oxygen for Lower Limb Trauma (HOLLT): an international multicentre randomized clinical trial; Is the T-shaped acetabular fracture really a “T”?; What causes cut-out of proximal femur nail anti-rotation device in intertrochanteric fractures?; Is the common femoral artery at risk with percutaneous fragility pelvis fixation?; Anterior pelvic ring pattern predicts displacement in lateral compression fractures; Differences in age-related characteristics among elderly patients with hip fractures.
Distal femoral resection in conventional total knee arthroplasty (TKA) utilizes an intramedullary guide to determine coronal alignment, commonly planned for 5° of valgus. However, a standard 5° resection angle may contribute to malalignment in patients with variability in the femoral anatomical and mechanical axis angle. The purpose of the study was to leverage deep learning (DL) to measure the femoral mechanical-anatomical axis angle (FMAA) in a heterogeneous cohort. Patients with full-limb radiographs from the Osteoarthritis Initiative were included. A DL workflow was created to measure the FMAA and validated against human measurements. To reflect potential intramedullary guide placement during manual TKA, two different FMAAs were calculated either using a line approximating the entire diaphyseal shaft, and a line connecting the apex of the femoral intercondylar sulcus to the centre of the diaphysis. The proportion of FMAAs outside a range of 5.0° (SD 2.0°) was calculated for both definitions, and FMAA was compared using univariate analyses across sex, BMI, knee alignment, and femur length.Aims
Methods
Transcription factor nuclear factor kappa B (NF-κB) plays a major role in the pathogenesis of chronic inflammatory diseases in all organ systems. Despite its importance, NF-κB targeted drug therapy to mitigate chronic inflammation has had limited success in preclinical studies. We hypothesized that sex differences affect the response to NF-κB treatment during chronic inflammation in bone. This study investigated the therapeutic effects of NF-κB decoy oligodeoxynucleotides (ODN) during chronic inflammation in male and female mice. We used a murine model of chronic inflammation induced by continuous intramedullary delivery of lipopolysaccharide-contaminated polyethylene particles (cPE) using an osmotic pump. Specimens were evaluated using micro-CT and histomorphometric analyses. Sex-specific osteogenic and osteoclastic differentiation potentials were also investigated in vitro, including alkaline phosphatase, Alizarin Red, tartrate-resistant acid phosphatase staining, and gene expression using reverse transcription polymerase chain reaction (RT-PCR).Aims
Methods
The June 2024 Spine Roundup360 looks at: Intraoperative navigation increases the projected lifetime cancer risk in patients undergoing surgery for adolescent idiopathic scoliosis; Intrawound vancomycin powder reduces delayed deep surgical site infections following posterior spinal fusion for adolescent idiopathic scoliosis; Characterizing negative online reviews of spine surgeons; Proximal junctional failure after surgical instrumentation in adult spinal deformity: biomechanical assessment of proximal instrumentation stiffness; Nutritional supplementation and wound healing: a randomized controlled trial.
Periprosthetic fracture and implant loosening are two of the major reasons for revision surgery of cementless implants. Optimal implant fixation with minimal bone damage is challenging in this procedure. This pilot study investigates whether vibratory implant insertion is gentler compared to consecutive single blows for acetabular component implantation in a surrogate polyurethane (PU) model. Acetabular components (cups) were implanted into 1 mm nominal under-sized cavities in PU foams (15 and 30 per cubic foot (PCF)) using a vibratory implant insertion device and an automated impaction device for single blows. The impaction force, remaining polar gap, and lever-out moment were measured and compared between the impaction methods.Aims
Methods
Surgical approaches that claim to be minimally invasive, such as the direct anterior approach (DAA), are reported to have a clinical advantage, but are technically challenging and may create more injury to the soft-tissues during joint exposure. Our aim was to quantify the effect of soft-tissue releases on the joint torque and femoral mobility during joint exposure for hip resurfacing performed via the DAA. Nine fresh-frozen hip joints from five pelvis to mid-tibia cadaveric specimens were approached using the DAA. A custom fixture consisting of a six-axis force/torque sensor and motion sensor was attached to tibial diaphysis to measure manually applied torques and joint angles by the surgeon. Following dislocation, the torques generated to visualize the acetabulum and proximal femur were assessed after sequential release of the joint capsule and short external rotators.Aims
Methods
A higher failure rate has been reported in haematogenous periprosthetic joint infection (PJI) compared to non-haematogenous PJI. The reason for this difference is unknown. We investigated the outcome of haematogenous and non-haematogenous PJI to analyze the risk factors for failure in both groups of patients. Episodes of knee or hip PJI (defined by the European Bone and Joint Infection Society criteria) treated at our institution between January 2015 and October 2020 were included in a retrospective PJI cohort. Episodes with a follow-up of > one year were stratified by route of infection into haematogenous and non-haematogenous PJI. Probability of failure-free survival was estimated using the Kaplan-Meier method, and compared between groups using log-rank test. Univariate and multivariate analysis was applied to assess risk factors for failure.Aims
Methods
Only a few studies have investigated the long-term health-related quality of life (HRQoL) in patients with an idiopathic scoliosis. The aim of this study was to investigate the overall HRQoL and employment status of patients with an idiopathic scoliosis 40 years after diagnosis, to compare it with that of the normal population, and to identify possible predictors for a better long-term HRQoL. We reviewed the full medical records and radiological reports of patients referred to our hospital with a scoliosis of childhood between April 1972 and April 1982. Of 129 eligible patients with a juvenile or adolescent idiopathic scoliosis, 91 took part in the study (71%). They were evaluated with full-spine radiographs and HRQoL questionnaires and compared with normative data. We compared the HRQoL between observation (n = 27), bracing (n = 46), and surgical treatment (n = 18), and between thoracic and thoracolumbar/lumbar (TL/L) curves.Aims
Methods
This study aimed to demonstrate the promoting effect of elastic fixation on fracture, and further explore its mechanism at the gene and protein expression levels. A closed tibial fracture model was established using 12 male Japanese white rabbits, and divided into elastic and stiff fixation groups based on different fixation methods. Two weeks after the operation, a radiograph and pathological examination of callus tissue were used to evaluate fracture healing. Then, the differentially expressed proteins (DEPs) were examined in the callus using proteomics. Finally, in vitro cell experiments were conducted to investigate hub proteins involved in this process.Aims
Methods
A fracture of the medial tibial plateau is a serious complication of Oxford mobile-bearing unicompartmental knee arthroplasty (OUKA). The risk of these fractures is reportedly lower when using components with a longer keel-cortex distance (KCDs). The aim of this study was to examine how slight varus placement of the tibial component might affect the KCDs, and the rate of tibial plateau fracture, in a clinical setting. This retrospective study included 255 patients who underwent 305 OUKAs with cementless tibial components. There were 52 males and 203 females. Their mean age was 73.1 years (47 to 91), and the mean follow-up was 1.9 years (1.0 to 2.0). In 217 knees in 187 patients in the conventional group, tibial cuts were made orthogonally to the tibial axis. The varus group included 88 knees in 68 patients, and tibial cuts were made slightly varus using a new osteotomy guide. Anterior and posterior KCDs and the origins of fracture lines were assessed using 3D CT scans one week postoperatively. The KCDs and rate of fracture were compared between the two groups.Aims
Methods
Biofilm-related infection is a major complication that occurs in orthopaedic surgery. Various treatments are available but efficacy to eradicate infections varies significantly. A systematic review was performed to evaluate therapeutic interventions combating biofilm-related infections on in vivo animal models. Literature research was performed on PubMed and Embase databases. Keywords used for search criteria were “bone AND biofilm”. Information on the species of the animal model, bacterial strain, evaluation of biofilm and bone infection, complications, key findings on observations, prevention, and treatment of biofilm were extracted.Aims
Methods
The August 2023 Spine Roundup360 looks at: Changes in paraspinal muscles correspond to the severity of degeneration in patients with lumbar stenosis; Steroid injections are not effective in the prevention of surgery for degenerative cervical myelopathy; A higher screw density is associated with fewer mechanical complications after surgery for adult spinal deformity; Methylprednisolone following minimally invasive lumbar decompression: a large prospective single-institution study; Occupancy rate of pedicle screw below 80% is a risk factor for upper instrumented vertebral fracture following adult spinal deformity surgery; Deterioration after surgery for degenerative cervical myelopathy: an observational study from the Canadian Spine Outcomes and Research Network.
The April 2023 Knee Roundup360 looks at: Does bariatric surgery reduce complications after total knee arthroplasty?; Mid-flexion stability in total knee arthroplasties implanted with kinematic alignment: posterior-stabilized versus medial-stabilized implants; Inflammatory response in robotic-arm-assisted versus conventional jig-based total knee arthroplasty; Journey II bicruciate stabilized (JII-BCS) and GENESIS II total knee arthroplasty: the CAPAbility, blinded, randomized controlled trial; Lifetime risk of revision and patient factors; Platelet-rich plasma use for hip and knee osteoarthritis in the USA; Where have the knee revisions gone?; Tibial component rotation in total knee arthroplasty: CT-based study of 1,351 tibiae.
The aim of the LightFix Trial was to evaluate the clinical outcomes for one year after the treatment of impending and completed pathological fractures of the humerus using the IlluminOss System (IS), and to analyze the performance of this device. A total of 81 patients with an impending or completed pathological fracture were enrolled in a multicentre, open label single cohort study and treated with IS. Inclusion criteria were visual analogue scale (VAS) Pain Scores > 60 mm/100 mm and Mirels’ Score ≥ 8. VAS pain, Musculoskeletal Tumor Society (MSTS) Upper Limb Function, and The European Organization for Research and Treatment of Cancer QoL Group Bone Metastases Module (QLQ-BM22) scores were all normalized to 100, and radiographs were obtained at baseline and at 14, 30, 90, 180, and 360 days postoperatively.Aims
Methods
Given the possible radiation damage and inaccuracy of radiological investigations, particularly in children, ultrasound and superb microvascular imaging (SMI) may offer alternative methods of evaluating new bone formation when limb lengthening is undertaken in paediatric patients. The aim of this study was to assess the use of ultrasound combined with SMI in monitoring new bone formation during limb lengthening in children. In this retrospective cohort study, ultrasound and radiograph examinations were performed every two weeks in 30 paediatric patients undergoing limb lengthening. Ultrasound was used to monitor new bone formation. The number of vertical vessels and the blood flow resistance index were compared with those from plain radiographs.Aims
Methods
The aim of this study was to investigate the impact of the level of upper instrumented vertebra (UIV) in frail patients undergoing surgery for adult spine deformity (ASD). Patients with adult spinal deformity who had undergone T9-to-pelvis fusion were stratified using the ASD-Modified Frailty Index into not frail, frail, and severely frail categories. ASD was defined as at least one of: scoliosis ≥ 20°, sagittal vertical axis (SVA) ≥ 5 cm, or pelvic tilt ≥ 25°. Means comparisons tests were used to assess differences between both groups. Logistic regression analyses were used to analyze associations between frailty categories, UIV, and outcomes.Aims
Methods
The October 2012 Children’s orthopaedics Roundup. 360. looks at: magnetic growing
The aim of this study was to review the provision of total elbow arthroplasties (TEAs) in England, including the incidence, the characteristics of the patients and the service providers, the types of implant, and the outcomes. We analyzed the primary TEAs recorded in the National Joint Registry (NJR) between April 2012 and December 2022, with mortality data from the Civil Registration of Deaths dataset. Linkage with Hospital Episode Statistics-Admitted Patient Care (HES-APC) data provided further information not collected by the NJR. The incidences were calculated using estimations of the populations from the Office for National Statistics. The annual number of TEAs performed by surgeons and hospitals was analyzed on a national and regional basis.Aims
Methods
Postoperative complication rates remain relatively high after adult spinal deformity (ASD) surgery. The extent to which modifiable patient-related factors influence complication rates in patients with ASD has not been effectively evaluated. The aim of this retrospective cohort study was to evaluate the association between modifiable patient-related factors and complications after corrective surgery for ASD. ASD patients with two-year data were included. Complications were categorized as follows: any complication, major, medical, surgical, major mechanical, major radiological, and reoperation. Modifiable risk factors included smoking, obesity, osteoporosis, alcohol use, depression, psychiatric diagnosis, and hypertension. Patients were stratified by the degree of baseline deformity (low degree of deformity (LowDef)/high degree of deformity (HighDef): below or above 20°) and age (Older/Younger: above or below 65 years). Complication rates were compared for modifiable risk factors in each age/deformity group, using multivariable logistic regression analysis to adjust for confounders.Aims
Methods
The aim of this study was to evaluate the suitability of the tapered cone stem in total hip arthroplasty (THA) in patients with excessive femoral anteversion and after femoral osteotomy. We included patients who underwent THA using Wagner Cone due to proximal femur anatomical abnormalities between August 2014 and January 2019 at a single institution. We investigated implant survival time using the endpoint of dislocation and revision, and compared the prevalence of prosthetic impingements between the Wagner Cone, a tapered cone stem, and the Taperloc, a tapered wedge stem, through simulation. We also collected Oxford Hip Score (OHS), visual analogue scale (VAS) satisfaction, and VAS pain by postal survey in August 2023 and explored variables associated with those scores.Aims
Methods
To determine the major risk factors for unplanned reoperations (UROs) following corrective surgery for adult spinal deformity (ASD) and their interactions, using machine learning-based prediction algorithms and game theory. Patients who underwent surgery for ASD, with a minimum of two-year follow-up, were retrospectively reviewed. In total, 210 patients were included and randomly allocated into training (70% of the sample size) and test (the remaining 30%) sets to develop the machine learning algorithm. Risk factors were included in the analysis, along with clinical characteristics and parameters acquired through diagnostic radiology.Aims
Methods
This study aimed to develop and validate a fully automated system that quantifies proximal femoral bone mineral density (BMD) from CT images. The study analyzed 978 pairs of hip CT and dual-energy X-ray absorptiometry (DXA) measurements of the proximal femur (DXA-BMD) collected from three institutions. From the CT images, the femur and a calibration phantom were automatically segmented using previously trained deep-learning models. The Hounsfield units of each voxel were converted into density (mg/cm3). Then, a deep-learning model trained by manual landmark selection of 315 cases was developed to select the landmarks at the proximal femur to rotate the CT volume to the neutral position. Finally, the CT volume of the femur was projected onto the coronal plane, and the areal BMD of the proximal femur (CT-aBMD) was quantified. CT-aBMD correlated to DXA-BMD, and a receiver operating characteristic (ROC) analysis quantified the accuracy in diagnosing osteoporosis.Aims
Methods
This study aimed to compare the performance of survival prediction models for bone metastases of the extremities (BM-E) with pathological fractures in an Asian cohort, and investigate patient characteristics associated with survival. This retrospective cohort study included 469 patients, who underwent surgery for BM-E between January 2009 and March 2022 at a tertiary hospital in South Korea. Postoperative survival was calculated using the PATHFx3.0, SPRING13, OPTIModel, SORG, and IOR models. Model performance was assessed with area under the curve (AUC), calibration curve, Brier score, and decision curve analysis. Cox regression analyses were performed to evaluate the factors contributing to survival.Aims
Methods
The purpose of this study was to compare reoperation and revision rates of double plating (DP), single plating using a lateral locking plate (SP), or distal femoral arthroplasty (DFA) for the treatment of periprosthetic distal femur fractures (PDFFs). All patients with PDFF primarily treated with DP, SP, or DFA between 2008 and 2022 at a university teaching hospital were included in this retrospective cohort study. The primary outcome was revision surgery for failure following DP, SP, or DFA. Secondary outcome measures included any reoperation, length of hospital stay, and mortality. All basic demographic and relevant implant and injury details were collected. Radiological analysis included fracture classification and evaluation of metaphyseal and medial comminution.Aims
Methods
Disorders of bone integrity carry a high global disease burden, frequently requiring intervention, but there is a paucity of methods capable of noninvasive real-time assessment. Here we show that miniaturized handheld near-infrared spectroscopy (NIRS) scans, operated via a smartphone, can assess structural human bone properties in under three seconds. A hand-held NIR spectrometer was used to scan bone samples from 20 patients and predict: bone volume fraction (BV/TV); and trabecular (Tb) and cortical (Ct) thickness (Th), porosity (Po), and spacing (Sp).Aims
Methods
The timing of when to remove a circular frame is crucial; early removal results in refracture or deformity, while late removal increases the patient morbidity and delay in return to work. This study was designed to assess the effectiveness of a staged reloading protocol. We report the incidence of mechanical failure following both single-stage and two stage reloading protocols and analyze the associated risk factors. We identified consecutive patients from our departmental database. Both trauma and elective cases were included, of all ages, frame types, and pathologies who underwent circular frame treatment. Our protocol is either a single-stage or two-stage process implemented by defunctioning the frame, in order to progressively increase the weightbearing load through the bone, and promote full loading prior to frame removal. Before progression, through the process we monitor patients for any increase in pain and assess radiographs for deformity or refracture.Aims
Methods
Robotic-assisted total knee arthroplasty (TKA) has proven higher accuracy, fewer alignment outliers, and improved short-term clinical outcomes when compared to conventional TKA. However, evidence of cost-effectiveness and individual superiority of one system over another is the subject of further research. Despite its growing adoption rate, published results are still limited and comparative studies are scarce. This review compares characteristics and performance of five currently available systems, focusing on the information and feedback each system provides to the surgeon, what the systems allow the surgeon to modify during the operation, and how each system then aids execution of the surgical plan. Cite this article: Abstract
The June 2012 Children’s orthopaedics Roundup. 360. looks at; open reduction for DDH; growing
A consecutive series of 85 patients with Duchenne’s muscular dystrophy who underwent spinal fusion over a period of 16 years was followed up with regard to the progression of the scoliosis and pelvic obliquity. Of 74 patients with adequate radiographic follow-up, 55 were instrumented with the Luque single-unit
The aim of this study was to compare the functional and radiological outcomes and the complication rate after nail and plate fixation of unstable fractures of the ankle in elderly patients. In this multicentre study, 120 patients aged ≥ 60 years with an acute unstable AO/OTA type 44-B fracture of the ankle were randomized to fixation with either a nail or a plate and followed for 24 months after surgery. The primary outcome measure was the American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot score. Secondary outcome measures were the Manchester-Oxford Foot Questionnaire, the Olerud and Molander Ankle score, the EuroQol five-dimension questionnaire, a visual analogue score for pain, complications, the quality of reduction of the fracture, nonunion, and the development of osteoarthritis.Aims
Methods
A modification of a previously reported one-stage technique for reduction and stabilisation of severe spondylolisthesis using a posterior route is described. Reduction is obtained by inserting Harrington
The December 2022 Children’s orthopaedics Roundup360 looks at: Immobilization of torus fractures of the wrist in children (FORCE): a randomized controlled equivalence trial in the UK; Minimally invasive method in treatment of idiopathic congenital vertical talus: recurrence is uncommon; “You’re O.K. Anaesthesia”: closed reduction of displaced paediatric forearm and wrist fractures in the office without anaesthesia; Trunk range of motion and patient outcomes after anterior vertebral body tethering versus posterior spinal fusion: comparison using computerized 3D motion capture technology; Selective dorsal rhizotomy for individuals with spastic cerebral palsy; Scheuermann’s kyphosis and posterior spinal fusion; All-pedicle-screw constructs in skeletally immature patients with severe idiopathic early-onset scoliosis; Proximal femoral screw hemiepiphysiodesis in children with cerebral palsy.
This study investigated the effects of β-caryophyllene (BCP) on protecting bone from vitamin D deficiency in mice fed on a diet either lacking (D-) or containing (D+) vitamin D. A total of 40 female mice were assigned to four treatment groups (n = 10/group): D+ diet with propylene glycol control, D+ diet with BCP, D-deficient diet with control, and D-deficient diet with BCP. The D+ diet is a commercial basal diet, while the D-deficient diet contains 0.47% calcium, 0.3% phosphorus, and no vitamin D. All the mice were housed in conditions without ultraviolet light. Bone properties were evaluated by X-ray micro-CT. Serum levels of klotho were measured by enzyme-linked immunosorbent assay.Aims
Methods
The development of spinal deformity in children with underlying neurodisability can affect their ability to function and impact on their quality of life, as well as compromise provision of nursing care. Patients with neuromuscular spinal deformity are among the most challenging due to the number and complexity of medical comorbidities that increase the risk for severe intraoperative or postoperative complications. A multidisciplinary approach is mandatory at every stage to ensure that all nonoperative measures have been applied, and that the treatment goals have been clearly defined and agreed with the family. This will involve input from multiple specialities, including allied healthcare professionals, such as physiotherapists and wheelchair services. Surgery should be considered when there is significant impact on the patients’ quality of life, which is usually due to poor sitting balance, back or costo-pelvic pain, respiratory complications, or problems with self-care and feeding. Meticulous preoperative assessment is required, along with careful consideration of the nature of the deformity and the problems that it is causing. Surgery can achieve good curve correction and results in high levels of satisfaction from the patients and their caregivers. Modern modular posterior instrumentation systems allow an effective deformity correction. However, the risks of surgery remain high, and involvement of the family at all stages of decision-making is required in order to balance the risks and anticipated gains of the procedure, and to select those patients who can mostly benefit from spinal correction.
Foreign-body reaction to polyglycolide (PGA) implants has been described in man. Many animal experiments have verified the mechanical properties of fixation devices made from PGA, but a significant foreign-body reaction has not been described. We studied the effect of PGA
Navigation devices are designed to improve a surgeon’s accuracy in positioning the acetabular and femoral components in total hip arthroplasty (THA). The purpose of this study was to both evaluate the accuracy of an optical computer-assisted surgery (CAS) navigation system and determine whether preoperative spinopelvic mobility (categorized as hypermobile, normal, or stiff) increased the risk of acetabular component placement error. A total of 356 patients undergoing primary THA were prospectively enrolled from November 2016 to March 2018. Clinically relevant error using the CAS system was defined as a difference of > 5° between CAS and 3D radiological reconstruction measurements for acetabular component inclination and anteversion. Univariate and multiple logistic regression analyses were conducted to determine whether hypermobile (Aims
Methods
Stüve-Wiedemann syndrome is an autosomal-recessive disorder characterised by bowing of the long bones, progressive scoliosis, episodic hyperthermia and respiratory distress, usually resulting in death in infancy. We reviewed five children with the condition who had been followed since birth and who survived into childhood with a mean age at operation of 7.8 years (5 to 14). There was marked functional impairment with dysplasia of the long bones and scoliosis. Treatment of the triplanar deformities of the femora involved the use of the Ilizarov technique with the Taylor Spatial Frame. Walking was preserved and improved in three children along with considerable enhancement of the appearance. Early insertion of a growing
To date, all surgical techniques used for reconstruction
of the pelvic ring following supra-acetabular tumour resection produce
high complication rates. We evaluated the clinical, oncological
and functional outcomes of a cohort of 35 patients (15 men and 20
women), including 21 Ewing’s sarcomas, six chondrosarcomas, three sarcomas
not otherwise specified, one osteosarcoma, two osseous malignant
fibrous histiocytomas, one synovial cell sarcoma and one metastasis.
The mean age of the patients was 31 years (8 to 79) and the latest
follow-up was carried out at a mean of 46 months (1.9 to 139.5)
post-operatively. We undertook a functional reconstruction of the pelvic ring using
polyaxial screws and titanium
Between October 2001 and September 2009 we lengthened 242 lower-limb segments in 180 patients using the Intramedullary Skeletal Kinetic Distractor (ISKD). Mechanical failure was defined either as breakage of the ISKD or failure of the internal mechanism to activate. Retrieved nails which failed mechanically were examined by the manufacturer for defects. In all, 15 ISKDs in 12 patients (13 limbs) failed mechanically representing an overall failure rate of 6.2%, with fracture of the device occurring in ten of the 15 failures. Two nails in one patient failed to lengthen and had to be replaced. The manufacturer detected an error in the assembly of the nail, which prompted a wide recall. One nail jammed after being forcefully inserted, and two nails failed to lengthen fully. Lengthening was achieved in all 12 patients, although three required a second operation to exchange a defective nail for a new, functioning device. The ISKD is a complex mechanical device which lengthens by the oscillation of two telescopic sections connected by a threaded
Accurate identification of the ankle joint centre is critical for estimating tibial coronal alignment in total knee arthroplasty (TKA). The purpose of the current study was to leverage artificial intelligence (AI) to determine the accuracy and effect of using different radiological anatomical landmarks to quantify mechanical alignment in relation to a traditionally defined radiological ankle centre. Patients with full-limb radiographs from the Osteoarthritis Initiative were included. A sub-cohort of 250 radiographs were annotated for landmarks relevant to knee alignment and used to train a deep learning (U-Net) workflow for angle calculation on the entire database. The radiological ankle centre was defined as the midpoint of the superior talus edge/tibial plafond. Knee alignment (hip-knee-ankle angle) was compared against 1) midpoint of the most prominent malleoli points, 2) midpoint of the soft-tissue overlying malleoli, and 3) midpoint of the soft-tissue sulcus above the malleoli.Aims
Methods
Ensuring correct rotation of the femoral component
is a challenging aspect of patellofemoral replacement surgery. Rotation
equal to the epicondylar axis or marginally more external rotation
is acceptable. Internal rotation is associated with poor outcomes.
This paper comprises two studies evaluating the use of the medial
malleolus as a landmark to guide rotation. We used 100 lower-leg anteroposterior radiographs to evaluate
the reliability of the medial malleolus as a landmark. Assessment
was made of the angle between the tibial shaft and a line from the
intramedullary
Our aim was to assess the intra- and inter-observer reliability in the establishment of the anterior pelvic plane used in imageless computer-assisted navigation. From this we determined the subsequent effects on version and inclination of the acetabular component. A cadaver model was developed with a specifically-designed
This study addressed two questions: first, does surgical correction of an idiopathic scoliosis increase the volume of the rib cage, and second, is it possible to evaluate the change in lung function after corrective surgery for adolescent idiopathic scoliosis (AIS) using biplanar radiographs of the ribcage with 3D reconstruction? A total of 45 patients with a thoracic AIS which needed surgical correction and fusion were included in a prospective study. All patients underwent pulmonary function testing (PFT) and low-dose biplanar radiographs both preoperatively and one year after surgery. The following measurements were recorded: forced vital capacity (FVC), slow vital capacity (SVC), and total lung capacity (TLC). Rib cage volume (RCV), maximum rib hump, main thoracic curve Cobb angle (MCCA), medial-lateral and anteroposterior diameter, and T4-T12 kyphosis were calculated from 3D reconstructions of the biplanar radiographs.Aims
Methods
The aim of this study was to evaluate the performance of first-generation annealed highly cross-linked polyethylene (HXLPE) in cementless total hip arthroplasty (THA). We retrospectively evaluated 29 patients (35 hips) who underwent THA between December 2000 and February 2002. The survival rate was estimated using the Kaplan-Meier method. Hip joint function was evaluated using the Japanese Orthopaedic Association (JOA) score. Two-dimensional polyethylene wear was estimated using Martell’s Hip Analysis Suite. We calculated the wear rates between years 1 and 5, 5 and 10, 10 and 15, and 15 and final follow-up.Aims
Methods
Femoral revision after cemented total hip replacement
(THR) might include technical difficulties, following essential cement
removal, which might lead to further loss of bone and consequently
inadequate fixation of the subsequent revision stem. . Femoral impaction allografting has been widely used in revision
surgery for the acetabulum, and subsequently for the femur. In combination
with a primary cemented stem, impaction grafting allows for femoral
bone restoration through incorporation and remodelling of the impacted
morsellized bone graft by the host skeleton. Cavitary bone defects
affecting meta-physis and diaphysis leading to a wide femoral shaft,
are ideal indications for this technique. Cancellous allograft bone
chips of 1 mm to 2 mm size are used, and tapered into the canal
with
Here we used a mature seven-day biofilm model of Mature biofilms of Aims
Methods
Traumatic atlanto-occipital dislocation in adults is usually fatal and survival without neurological deficit is rare. The surgical management of those who do survive is difficult and controversial. Most authorities recommend posterior occipitoaxial fusion, but this compromises cervical rotation. We describe a case in which a patient with a traumatic atlanto-occipital disruption but no neurological deficit was treated by atlanto-occipital fusion using a new technique consisting of cancellous bone autografting supported by an occipital plate linked by