Advertisement for orthosearch.org.uk
Results 1 - 100 of 214
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 5 | Pages 825 - 829
1 Sep 1993
Klosok J Pring D Jessop J Maffulli N

We compared the chevron and the Wilson metatarsal osteotomy for hallux valgus in a prospective randomised trial on 87 feet in 51 patients, reviewed at averages of 5.5 and 38 months after operation. The patients in the chevron group returned to work earlier and mobilised faster, but, at the later review, those in the Wilson group had better functional results and were more satisfied with the appearance of the foot. Correction of the hallux valgus angle was better maintained in patients in the Wilson group and they had a better range of motion at the metatarsophalangeal joint; fewer complained of metatarsalgia


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 964 - 972
1 Jul 2017
Duckworth AD Clement ND McEachan JE White TO Court-Brown CM McQueen MM

Aims. The aim of this prospective randomised controlled trial was to compare non-operative and operative management for acute isolated displaced fractures of the olecranon in patients aged ≥ 75 years. Patients and Methods. Patients were randomised to either non-operative management or operative management with either tension-band wiring or fixation with a plate. They were reviewed at six weeks, three and six months and one year after the injury. The primary outcome measure was the Disabilities of the Arm, Shoulder and Hand (DASH) score at one year. Results. A total of 19 patients were randomised to non-operative (n = 8) or operative (n = 11; tension-band wiring (n = 9), plate (n = 2)) management. The trial was stopped prematurely as the rate of complications (nine out of 11, 81.8%) in the operative group was considered to be unacceptable. There was, however, no difference in the mean DASH scores between the groups at all times. The mean score was 23 (0 to 59.6) in the non-operative group and 22 (2.5 to 57.8) in the operative group, one year after the injury (p = 0.763). There was no significant difference between groups in the secondary outcome measures of the Broberg and Morrey Score or the Mayo Elbow Score at any time during the one year following injury (all p ≥ 0.05). . Conclusion. These data further support the role of primary non-operative management of isolated displaced fractures of the olecranon in the elderly. However, the non-inferiority of non-operative management cannot be proved as the trial was stopped prematurely. Cite this article: Bone Joint J 2017;99-B:964–72


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 4 | Pages 615 - 619
1 Aug 1987
Bostman O Vainionpaa S Hirvensalo E Makela A Vihtonen K Tormala P Rokkanen P

Fifty-six patients with displaced malleolar fractures had open reduction and fixation of the fracture fragments using, by random selection, either biodegradable implants or metal AO plates and screws. The cylindrical biodegradable implants were made of polylactide-glycolide copolymer (polyglactin 910). The complications, radiographic results and functional recovery were studied prospectively. After follow-up of at least one year, no significant differences emerged in the complication rate or in the results of treatment between the two methods of fixation. Because of the advantage of avoiding the need to remove metal fixation after union, we now use biodegradable internal fixation routinely to treat displaced malleolar fractures.


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 4 | Pages 654 - 659
1 Jul 1994
Beard D Dodd C Trundle H Simpson A

We performed a prospective, double-blind, randomised, clinical trial to investigate the efficacy of two regimes of rehabilitation for knees with anterior cruciate ligament deficiency (ACLD). Fifty ACLD patients were randomly allocated to one of two treatment groups: a programme of muscle strengthening (T) or a programme designed to enhance proprioception and improve hamstring contraction reflexes (P). An indirect measure of proprioception, the reflex hamstring contraction latency (RHCL), and a functional scoring system were used to record the status of the knee before and after the 12-week course of physiotherapy. Sagittal knee laxity was also measured. There was improvement in mean RHCL and in the mean functional score in both groups after treatment. The improvement in group P was significantly greater than that in group T. There was no significant change in joint laxity after treatment in either group. In both groups there was a positive correlation between improvement in RHCL and functional gain.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 3 | Pages 464 - 465
1 Apr 2003
DE ROECK N


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 2 | Pages 183 - 188
1 Mar 2002
Rogmark C Carlsson Å Johnell O Sernbo I

It remains a matter of debate whether displaced fractures of the neck of the femur should be treated by internal fixation or arthroplasty. We have compared the two methods with regard to complications, mortality and functional outcome.

We studied 409 patients, aged 70 years and over, with subcapital fractures graded as Garden 3 or 4, in a two-year prospective multicentre study from 12 Swedish hospitals. They were randomised to internal fixation or arthroplasty. Patients who were mentally confused, bedridden or in a nursing-home were excluded from the survey.

After two years the rate of failure was 43% in the internal fixation (IF) and 6% in the arthroplasty group (p < 0.001). In the IF group 36% had impaired walking and 6% had severe pain compared with 25% and 1.5%, respectively, in the arthroplasty group (both p < 0.05). There was no difference in mortality.

With a high rate of failure and poor functional outcome after IF, we recommend primary arthroplasty for displaced fractures of the neck of the femur in patients over 70 years of age.


The Bone & Joint Journal
Vol. 96-B, Issue 4 | Pages 548 - 554
1 Apr 2014
Sun H Luo CF Zhong B Shi HP Zhang CQ Zeng BF

Our aim was to compare polylevolactic acid screws with titanium screws when used for fixation of the distal tibiofibular syndesmosis at mid-term follow-up. A total of 168 patients, with a mean age of 38.5 years (18 to 72) who were randomly allocated to receive either polylevolactic acid (n = 86) or metallic (n = 82) screws were included. The Baird scoring system was used to assess the overall satisfaction and functional recovery post-operatively. The demographic details and characteristics of the injury were similar in the two groups. The mean follow-up was 55.8 months (48 to 66). The Baird scores were similar in the two groups at the final follow-up. Patients in the polylevolactic acid group had a greater mean dorsiflexion (p = 0.011) and plantar-flexion of the injured ankles (p < 0.001). In the same group, 18 patients had a mild and eight patients had a moderate foreign body reaction. In the metallic groups eight had mild and none had a moderate foreign body reaction (p <  0.001). In total, three patients in the polylevolactic acid group and none in the metallic group had heterotopic ossification (p = 0.246).

We conclude that both screws provide adequate fixation and functional recovery, but polylevolactic acid screws are associated with a higher incidence of foreign body reactions.

Cite this article: Bone Joint J 2014;96-B:548–54.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 433 - 434
1 Mar 2005
VANDERESTRAETEN L BINNS MS


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 7 | Pages 984 - 988
1 Jul 2010
Guo JJ Tang N Yang HL Tang TS

We compared the outcome of closed intramedullary nailing with minimally invasive plate osteosynthesis using a percutaneous locked compression plate in patients with a distal metaphyseal fracture in a prospective study.

A total of 85 patients were randomised to operative stabilisation either by a closed intramedullary nail (44) or by minimally invasive osteosynthesis with a compression plate (41). Pre-operative variables included the patients’ age and the side and pattern of the fracture. Peri-operative variables were the operating time and the radiation time. Postoperative variables were wound problems, the time to union of the fracture, the functional American Orthopaedic Foot and Ankle surgery score and removal of hardware.

We found no significant difference in the pre-operative variables or in the time to union in the two groups. However, the mean radiation time and operating time were significantly longer in the locked compression plate group (3.0 vs 2.12 minutes, p < 0.001, and 97.9 vs 81.2 minutes, p < 0.001, respectively). After one year, all the fractures had united. Patients who had intramedullary nailing had a higher mean pain score, but better function, alignment and total American Orthopaedic Foot and Ankle surgery scores, although the differences were not statistically significant (p = 0.234, p = 0.157, p = 0.897, p = 0.177 respectively). Three (6.8%) patients in the intramedullary nailing group and six (14.6%) in the locked compression plate group showed delayed wound healing, and 37 (84.1%) in the former group and 38 (92.7%) in the latter group expressed a wish to have the implant removed.

We conclude that both closed intramedullary nailing and a percutaneous locked compression plate can be used safely to treat Orthopaedic Trauma Association type-43A distal metaphyseal fractures of the tibia. However, closed intramedullary nailing has the advantage of a shorter operating and radiation time and easier removal of the implant. We therefore prefer closed intramedullary nailing for patients with these fractures.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 2 | Pages 322 - 324
1 Mar 1991
Emery R Broughton N Desai K Bulstrode C Thomas T

We performed a randomised prospective trial to compare the results of 27 cemented and 26 uncemented bipolar hemiarthroplasties in active patients with displaced subcapital fractures of the femoral neck. After a mean follow-up of 17 months, significantly more of the uncemented group were experiencing pain in the hip and using more walking aids than the patients in the cemented group. The incidence of postoperative complications, the early mortality rate and the operating time and blood loss were not significantly different. Using otherwise identical prostheses the early results were much better with a cemented Thompson stem than with an uncemented Austin Moore stem


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 4 | Pages 451 - 454
1 Apr 2008
Amin A Watson A Mangwani J Nawabi DH Ahluwalia R Loeffler M

We undertook a prospective randomised controlled trial to investigate the efficacy of autologous retransfusion drains in reducing the need for allogenic blood requirement after unilateral total knee replacement. We also monitored the incidence of post-operative complications. There were 86 patients in the control group, receiving standard care with a vacuum drain, and 92 who received an autologous drain and were retransfused postoperatively. Following serial haemoglobin measurements at 24, 48 and 72 hours, we found no difference in the need for allogenic blood between the two groups (control group 15.1%, retransfusion group 13% (p = 0.439)). The incidence of post-operative complications, such as wound infection, deep-vein thrombosis and chest infection, was also comparable between the groups. There were no adverse reactions associated with the retransfusion of autologous blood. Based on this study, the cost-effectiveness and continued use of autologous drains in total knee replacement should be questioned


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 4 | Pages 650 - 652
1 Jul 1993
Birch N Sly C Brooks S Powles D

We report a prospective, randomised, controlled trial of the effect of either a non-steroidal anti-inflammatory drug (diclofenac sodium) or physiotherapy on the recovery of knee function after arthroscopy. At 42 days after surgery there was no significant benefit from either form of postoperative treatment compared with the control group. Complications attributable to the anti-inflammatory drug occurred in 9.6% of the patients so treated. Neither the routine administration of a non-steroidal anti-inflammatory agent nor routine physiotherapy is justified after arthroscopy of the knee


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 10 | Pages 1397 - 1401
1 Oct 2005
Walmsley PJ Kelly MB Hill RMF Brenkel I

The routine use of surgical drains in total hip arthroplasty remains controversial. They have not been shown to decrease the rate of wound infection significantly and can provide a retrograde route for it. Their use does not reduce the size or incidence of post-operative wound haematomas. This prospective, randomised study was designed to evaluate the role of drains in routine total hip arthroplasty.

We investigated 552 patients (577 hips) undergoing unilateral or bilateral total hip arthroplasty who had been randomised to either having a drain for 24 hours or not having a drain. All patients followed standardised pre-, intra-, and post-operative regimes and were independently assessed using the Harris hip score before operation and at six, 18 and 36 months follow-up.

The rate of superficial and deep infection was 2.9% and 0.4%, respectively, in the drained group and 4.8% and 0.7%, respectively in the undrained group. One patient in the undrained group had a haematoma which did not require drainage or transfusion. The rate of transfusion after operation in the drained group was significantly higher than for undrained procedures (p < 0.042). The use of a drain did not influence the post-operative levels of haemoglobin, the revision rates, Harris hip scores, the length of hospital stay or the incidence of thromboembolism. We conclude that drains provide no clear advantage at total hip arthroplasty, represent an additional cost, and expose patients to a higher risk of transfusion.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 7 | Pages 858 - 863
1 Jul 2007
Boutron I Ravaud P Nizard R

Randomised controlled trials represent the gold standard in the evaluation of outcome of treatment. They are needed because differences between treatment effects have been minimised and observational studies may give a biased estimation of the outcome. However, conducting this kind of trial is challenging. Several methodological issues, including patient or surgeon preference, blinding, surgical standardisation, as well as external validity, have to be addressed in order to lower the risk of bias. Specific tools have been developed in order to take into account the specificity of evaluation of the literature on non-pharmacological intervention. A better knowledge of methodological issues will allow the orthopaedic surgeon to conduct more appropriate studies and to better appraise the limits of his intervention.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 12 | Pages 1604 - 1610
1 Dec 2012
Angadi DS Brown S Crawfurd EJP

The aim of this prospective randomised study was to compare the clinical and radiological results of a cemented all-polyethylene Ultima acetabular component with those of a cementless porous-coated acetabular component (PFC) following total hip replacement (THR). A total of 287 patients received either a polyethylene acetabular component (group A) or a cobalt–chromium porous-coated component (group B) with an identical cemented femoral component and 28 mm cobalt-chromium head, thus making it the largest study of its type. Patients were evaluated radiologically and clinically using the Harris hip score (HHS). Group A comprised 183 patients (73 male, 110 female) with a mean age of 71.3 years (55 to 89). Group B comprised 104 patients (48 male, 56 female) with a mean age of 69.8 years (56 to 89). A total of 16 patients (13 in Group A, three in Group B) did not have post-operative data for analysis. The mean follow-up in group A was 7.52 years (0.4 to 15.0) and in Group B 7.87 years (0.5 to 14.0).

At final follow-up the mean HHS was similar between groups A and B (74.5 (25 to 100) and 78.0 (37 to 100), respectively; p = 0.068). The total number of revisions for any cause was 28, 17 of which were in group A and 11 in group B. The ten-year survivorship was 86.8% (95% confidence interval (CI) 78.4 to 92.1) and 89.2% (95% CI 78.3 to 94.8) for groups A and B, respectively (log-rank p-value = 0.938). A total of 20 cemented and two cementless acetabular components had evidence of acetabular radiolucencies or acetabular component migration at last follow-up (p = 0.001).

These results indicate that patients with a cemented all-polyethylene and cementless porous-coated polyethylene lined acetabular component have similar long-term clinical outcomes.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 3 | Pages 335 - 341
1 Mar 2007
Albert J Meadeb J Guggenbuhl P Marin F Benkalfate T Thomazeau H Chalès G

In a prospective randomised trial of calcifying tendinitis of the rotator cuff, we compared the efficacy of dual treatment sessions delivering 2500 extracorporeal shock waves at either high- or low-energy, via an electromagnetic generator under fluoroscopic guidance. Patients were eligible for the study if they had more than a three-month history of calcifying tendinitis of the rotator cuff, with calcification measuring 10 mm or more in maximum dimension. The primary outcome measure was the change in the Constant and Murley Score. A total of 80 patients were enrolled (40 in each group), and were re-evaluated at a mean of 110 (41 to 255) days after treatment when the increase in Constant and Murley score was significantly greater (t-test, p = 0.026) in the high-energy treatment group than in the low-energy group. The improvement from the baseline level was significant in the high-energy group, with a mean gain of 12.5 (−20.7 to 47.5) points (p < 0.0001). The improvement was not significant in the low-energy group. Total or subtotal resorption of the calcification occurred in six patients (15%) in the high-energy group and in two patients (5%) in the low-energy group. High-energy shock-wave therapy significantly improves symptoms in refractory calcifying tendinitis of the shoulder after three months of follow-up, but the calcific deposit remains unchanged in size in the majority of patients


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 1 | Pages 83 - 85
1 Jan 1991
Hooper G Keddell R Penny I

We performed a prospective randomised trial on matched groups of patients with displaced tibial shaft fractures to compare conservative treatment with closed intramedullary nailing. The results showed conclusively that intramedullary nailing gave more rapid union with less malunion and shortening. Nailed patients had less time off work with a more predictable and rapid return to full function. We therefore consider that closed intramedullary nailing is the most efficient treatment for displaced fractures of the tibial shaft


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 1 | Pages 13 - 16
1 Jan 1997
Günal I Taymaz A Köse N Göktürk E Seber S

We have compared the results of simple patellectomy (group A, n = 16) and patellectomy with advancement of the vastus medialis obliquus (group B, n = 12) in a prospective, randomised trial, with a minimum follow-up of three years. The results in group B were significantly better (p < 0.001) than those in group A. Although the patella should be preserved if possible, we advocate advancement of the vastus medialis obliquus when patellectomy is necessary


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 5 | Pages 839 - 842
1 Sep 1990
O'Doherty D Lowrie I Magnussen P Gregg P

We report a prospective randomised trial comparing Keller's arthroplasty and arthrodesis of the first metatarsophalangeal joint for the management of symptomatic hallux valgus and hallux rigidus in the older patient. In 81 patients (110 feet), with a minimum of two years follow-up, both procedures gave a similar degree of patient satisfaction and symptom relief. The incidence of metatarsalgia was also similar. As there were no obvious advantages to arthrodesis, and since six out of 50 arthrodesed toes required revision, we suggest that Keller's arthroplasty is the better operation in these patients


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 6 | Pages 918 - 920
1 Nov 1993
Wright K Moran C Briggs P

Exposure to blood is a hazard for all surgeons. We assessed the incidence of glove perforation and needlestick injury from a new blunt taperpoint needle designed to penetrate tissues other than skin with the minimum of force. We performed a prospective, randomised trial comparing the incidence of perforations of surgical gloves with the new needle and a standard cutting needle during wound closure after hip arthroplasties. There was at least one glove perforation in 46 of 69 such procedures (67%). The use of the taperpoint needle produced a significant decrease in perforations (p = 0.049)


The Bone & Joint Journal
Vol. 99-B, Issue 8 | Pages 1095 - 1101
1 Aug 2017
Fuglesang HFS Flugsrud GB Randsborg PH Oord P Benth JŠ Utvåg SE

Aims. This is a prospective randomised controlled trial comparing the functional outcomes of plate fixation and elastic stable intramedullary nailing (ESIN) of completely displaced mid-shaft fractures of the clavicle in the active adult population. Patients and Methods. We prospectively recruited 123 patients and randomised them to either plate fixation or ESIN. Patients completed the Quick Disabilities of the Arm, Shoulder and Hand (DASH) score at one to six weeks post-operatively. They were followed up at six weeks, three and six months and one year with radiographs, and their clinical outcome was assessed using both the DASH and the Constant Score. Results. Plate fixation provided a faster functional recovery during the first six months compared with ESIN, but there was no difference after one year. The duration of surgery was shorter for ESIN (mean 53.4 minutes, 22 to 120) than for plate fixation (mean 69.7 minutes, 35 to 106, p < 0.001). The recovery after ESIN was slower with increasing fracture comminution and with open reduction (p < 0.05). Conclusion. Both methods return the patients to their pre-injury functional levels, but plate fixation has a faster recovery period in comminuted fractures than ESIN. ESIN has a shorter operative time and lower infection and implant rates of failure when using 2.5 mm nails or wider, suggesting that this is the preferred method in mid-shaft fractures with no comminution, whereas plate fixation is the superior method in comminuted fractures. Cite this article: Bone Joint J 2017;99-B:1095–1101


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 3 | Pages 445 - 447
1 May 1993
Desjardins A Roy A Paiement G Newman N Pedlow F Desloges D Turcotte R

We conducted a prospective randomised trial to compare the results of anatomical reduction and medial displacement osteotomy in 127 consecutive patients with unstable intertrochanteric fractures, of whom 109 completed the study. After an average follow-up of 11 months, we found no significant differences in walking ability, social status or failure of fixation in the two groups. Postoperative complication rates and the early mortality rate were not significantly different, but operating time and blood loss were significantly higher in the osteotomy group. With the use of modern sliding hip screws, medial displacement osteotomy is rarely indicated for unstable intertrochanteric fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 3 | Pages 404 - 409
1 May 1996
McQueen MM Hajducka C Court-Brown CM

We performed a prospective, randomised trial on 120 patients with redisplaced fractures of the distal radius comparing four methods of treatment. The four treatment groups, each containing 30 patients, were remanipulation and plaster, open reduction and bone grafting, and closed external fixation with and without mobilisation of the wrist at three weeks. The radiological results showed improvement in angulation of the distal radius for the open reduction and bone grafting group. Functional results at six weeks, three and six months and at one year, however, showed no difference between any of the four groups. The main influence on final outcome was carpal malalignment which had a statistically significant negative effect on function


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 3 | Pages 433 - 437
1 May 1997
Antich-Adrover P Martí-Garin D Murias-Alvarez J Puente-Alonso C

We performed a prospective, randomised trial in 39 patients with open tibial fractures treated initially by external fixation to compare cast immobilisation (group A) and intramedullary nailing (group B) as a sequential protocol planned from the onset of treatment. The results showed that group B achieved faster union (p < 0.05) than group A with less malunion or shortening and a greater range of movement. Patients treated by intramedullary nailing required fewer radiographs and outpatient visits (p = 0.0015) and had a more predictable and rapid return to full function. We feel that these severe fractures are better treated by delayed intramedullary nailing and that this has an acceptable rate of complications


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 3 | Pages 371 - 373
1 May 1997
Nicolai P Aldam CH Allen PW

An intact barrier between the hands of the surgeon and the patient remains the single most important factor in protection against infection for both. Increasing the awareness of possible glove perforation without skin penetration will decrease the risk of contamination. We performed a prospective, randomised trial comparing the incidence of glove perforation using a new type of glove (Regent Biogel Reveal) and standard double-gloves in total hip and knee replacement. One or more perforations was detected in 14.6% of all gloves. The new gloves increased significantly the awareness of perforation. Multiple perforations at the base of the ring finger were found in surgeons who wore wedding rings during the operation and we recommend that rings be removed before undertaking surgery


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 12 | Pages 1613 - 1617
1 Dec 2006
Karunakar MA Sen A Bosse MJ Sims SH Goulet JA Kellam JF

Our study was designed to compare the effect of indometacin with that of a placebo in reducing the incidence of heterotopic ossification in a prospective, randomised trial. A total of 121 patients with displaced fractures of the acetabulum treated by operation through a Kocher-Langenbeck approach was randomised to receive either indometacin (75 mg) sustained release, or a placebo once daily for six weeks. The extent of heterotopic ossification was evaluated on plain radiographs three months after operation. Significant ossification of Brooker grade III to IV occurred in nine of 59 patients (15.2%) in the indometacin group and 12 of 62 (19.4%) receiving the placebo. We were unable to demonstrate a statistically significant reduction in the incidence of severe heterotopic ossification with the use of indometacin when compared with a placebo (p = 0.722). Based on these results we cannot recommend the routine use of indometacin for prophylaxis against heterotopic ossification after isolated fractures of the acetabulum


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 9 | Pages 1214 - 1221
1 Sep 2008
Egol K Walsh M Tejwani N McLaurin T Wynn C Paksima N

We performed a prospective, randomised trial to evaluate the outcome after surgery of displaced, unstable fractures of the distal radius. A total of 280 consecutive patients were enrolled in a prospective database and 88 identified who met the inclusion criteria for surgery. They were randomised to receive either bridging external fixation with supplementary Kirschner-wire fixation or volar-locked plating with screws. Both groups were similar in terms of age, gender, hand dominance, fracture pattern, socio-economic status and medical co-morbidities. Although the patients treated by volar plating had a statistically significant early improvement in the range of movement of the wrist, this advantage diminished with time and in absolute terms the difference in range of movement was clinically unimportant. Radiologically, there were no clinically significant differences in the reductions, although more patients with AO/OTA (Orthopaedic Trauma Association) type C fractures were allocated to the external fixation group. The function at one year was similar in the two groups. No clear advantage could be demonstrated with either treatment but fewer re-operations were required in the external fixation group


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 6 | Pages 863 - 868
1 Aug 2003
Wong KC Hung LK Ho PC Wong JMW

Endoscopic carpal tunnel release has the advantage over open release of reduced tissue trauma and postoperative morbidity. Limited open carpal tunnel release has also been shown to have comparable results, but is easier to perform and is safer. We have compared the results of both techniques in a prospective, randomised trial. Thirty patients with bilateral carpal tunnel syndrome had simultaneous bilateral release. The technique of release was randomly allocated to either two-portal endoscopic release (ECTR) or limited open release using the Strickland instrumentation (LOCTR). The results showed that the outcome was similar at follow-up of one year using both techniques. However, the LOCTR group had significantly less tenderness of the scar at the second and fourth postoperative week (p < 0.01). There was also less thenar and hypothenar (pillar) pain after LOCTR. Subjective evaluation showed a preference for LOCTR


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 3 | Pages 395 - 399
1 May 1996
van Laarhoven CJHM Meeuwis JD van der Werken C

In a prospective, randomised trial of 81 patients with fractures of the ankle of AO types A, B and C we compared two regimes of postoperative management after internal fixation. The patients were mobilised either non-weight-bearing with crutches or weight-bearing in a below-knee walking plaster. We found a temporary benefit in subjective evaluation only (65 v 50 points, Mann-Whitney test, cft, p = 0.02) for those with a below-knee walking plaster. There were no significant differences between the groups in the loaded dorsal range of movement (25° v 23°, Mann-Whitney test, cft, p = 0.16) or in the overall clinical result. Both treatments were considered to be satisfactory and their choice depends on the ability to mobilise non-weight-bearing, wound healing, the type of work and personal preference


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 3 | Pages 357 - 361
1 Aug 1981
Sikorski J Barrington R

A prospective randomised trial of surgical treatment for the displaced subcapital femoral fracture in patients of 70 years or more is presented. Two hundred and eighteen patients were randomly allocated into one of three treatment groups: manipulative reduction and internal fixation using Garden screws; Thompson hemiarthroplasty through a posterior (Moore) approach; and Thompson hemiarthroplasty through an anterolateral (McKee) approach. There is no significant difference in the mortality of the internal fixation and posterior arthroplasty groups. Both groups showed a significantly higher mortality than patients operated on through the anterior approach. The technical results of operation were worse in the internally fixed group, with only 40 per cent being satisfactory. Mobilisation was best achieved after the posterior approach. It is concluded that Thompson hemiarthroplasty, using an anterolateral approach, is the safest operation in this group of patients


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 2 | Pages 217 - 219
1 Mar 1996
Hubbard MJS

In a prospective randomised trial 76 knees with isolated degenerative changes in the medial femoral condyle of grades 3 or 4 were treated by either arthroscopic debridement (40) or washout (36). All knees were followed up for at least one year and 58 for five years. The mean follow-up time was 4.5 years in the debridement group and 4.3 years in the washout group. At one year 32 of the debridement group and five of the washout group were painfree and at five years 19 of a total of 32 survivors in the debridement group and three of the 26 in the washout group were also free from pain. The mean improvement in a modified Lysholm score was 28 for the debridement group at one year and 21 at five years. In the washout group it was only 5 at one year and 4 at five years. For knees with lesions of the medial femoral condyle of grades 3 or 4, arthroscopic debridement appears to be the treatment of choice with over half the patients free from pain after five years


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 8 | Pages 1173 - 1175
1 Nov 2001
Davidson JS Brown DJ Barnes SN Bruce CE

Torus (buckle) fractures of the distal radius are common in childhood. Based on the results of a postal questionnaire and a prospective, randomised trial, we describe a simple treatment for this injury, which saves both time and money. Over a six-month period, we randomised 201 consecutive patients with this injury to treatment with either a traditional forearm plaster-of-Paris cast or a ‘Futura-type’ wrist splint. All patients were treated for a period of three weeks, followed by clinical and radiological review. There was no difference in outcome between the two groups, and all patients had a good result. Only one patient did not tolerate the splint which was replaced by a cast. The questionnaire showed a marked variation in the way in which these injuries are treated with regard to the method and period of immobilisation, the number of follow-up visits and radiographs taken. We suggest that a ‘Futura-type’ wrist splint can be used to treat these fractures. The patient should be reviewed on the following day to confirm the diagnosis and to give appropriate advice. There is no evidence that further follow-up is required. This simple treatment has major benefits in terms of cost and reduction of the number of attendances


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 5 | Pages 646 - 655
1 May 2005
Victor J Banks S Bellemans J

We performed a prospective, randomised trial of 44 patients to compare the functional outcomes of a posterior-cruciate-ligament-retaining and posterior-cruciate-ligament-substituting total knee arthroplasty, and to gain a better understanding of the in vivo kinematic behaviour of both devices. At follow-up at five years, no statistically significant differences were found in the clinical outcome measurements for either design. The prevalence of radiolucent lines and the survivorship were the same. In a subgroup of 15 knees, additional image-intensifier analysis in the horizontal and sagittal planes was performed during step-up and lunge activity. Our analysis revealed striking differences. Lunge activity showed a mean posterior displacement of both medial and lateral tibiofemoral contact areas (roll-back) which was greater and more consistent in the cruciate-substituting than in the cruciate-retaining group (medial p < 0.0001, lateral p = 0.011). The amount of posterior displacement could predict the maximum flexion which could be achieved (p = 0.018). Forward displacement of the tibiofemoral contact area in flexion during stair activity was seen more in the cruciate-retaining than in the cruciate-substituting group. This was attributed mainly to insufficiency of the posterior cruciate ligament and partially to that of the anterior cruciate ligament. We concluded that, despite similar clinical outcomes, there are significant kinematic differences between cruciate-retaining and cruciate-substituting arthroplasties


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 2 | Pages 206 - 212
1 Mar 2001
Davison JNS Calder SJ Anderson GH Ward G Jagger C Harper WM Gregg PJ

We performed a prospective, randomised trial comparing three treatments for displaced intracapsular fractures of the hip in 280 patients aged 65 to 79 years. The mean patient survival was significantly higher in the group undergoing reduction and internal fixation (79 months) compared with that with a cemented Thompson hemiarthroplasty or a cemented Monk bipolar hemiarthroplasty (61 months and 68 months, respectively). After three years, 32 of 93 patients (34.4%) who had undergone fixation had local complications, necessitating further intervention in 28 (30%). There were no significant differences in the functional outcome in survivors, who were reviewed annually to five years. Either reduction and internal fixation or cemented hemiarthroplasty may be offered as alternative treatments for a displaced intracapsular fracture in a mobile and mentally competent patient under the age of 80 years. The choice of procedure by the patient and the surgeon should be determined by the realisation that the use of internal fixation is associated with a 30% risk of failure requiring further surgery. If this is accepted, however, hemiarthroplasty is avoided, which, in our study has a significantly shorter mean survival time. The use of a bipolar prosthesis has no significant advantage


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 5 | Pages 671 - 674
1 Jul 2003
Straw R Kulkarni S Attfield S Wilton TJ

We report the results of a prospective randomised trial which assessed the role of the posterior cruciate ligament (PCL) following total knee replacement (Genesis I; Smith and Nephew, Memphis, Tennessee). Over a four-year period, 211 patients underwent total knee replacement by the senior author (TJW). They were randomised at surgery to have the PCL either retained, excised or substituted with a posterior stabilised insert. If it was not possible to retain the ligament due to soft-tissue imbalance, it was released from its tibial insertion until suitable tension was obtained. This created a fourth group, those who were intended preoperatively to have the ligament retained, but in whom it was partially released as a result of findings at the time of surgery. All patients were evaluated using the Knee Society rating system (adapted from Insall). A total of 188 patients (212 knees) was available for follow-up at a mean of 3.5 years after surgery. Preoperatively, there was a varus deformity in 191 knees (90%) and a valgus deformity in 21 (10%). There were no statistical differences in the knee or function scores or the range of movement between the excised, retained and substituted groups. There were, however, significantly worse knee and function scores in the group in whom the PCL was released (p = 0.002)


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 6 | Pages 886 - 890
1 Aug 2002
Holen KJ Tegnander A Bredland T Johansen OJ Sæther OD Eik-Nes SH Terjesen T

The aim of this study was to evaluate whether universal (all neonates) or selective (neonates belonging to the risk groups) ultrasound screening of the hips should be recommended at birth. We carried out a prospective, randomised trial between 1988 and 1992, including all newborn infants at our hospital. A total of 15 529 infants was randomised to either clinical screening and ultrasound examination of all hips or clinical screening of all hips and ultrasound examination only of those at risk. The effect of the screening was assessed by the rate of late detection of congenital or developmental hip dysplasia in the two groups. During follow-up of between six and 11 years, only one late-detected hip dysplasia was seen in the universal group, compared with five in the subjective group, representing a rate of 0.13 and 0.65 per 1000, respectively. The difference in late detection between the two groups was not statistically significant (p = 0.22). When clinical screening is of high quality, as in our study, the effect of an additional ultrasound examination, measured as late-presenting hip dysplasia, is marginal. Under such circumstances, we consider that universal ultrasound screening is not necessary, but recommend selective ultrasound screening for neonates with abnormal or suspicious clinical findings and those with risk factors for hip dysplasia


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 3 | Pages 426 - 430
1 Apr 2003
Lykke N Lerud PJ Strømsøe K Thorngren K

In a prospective, randomised trial, we compared the use of three Ullevaal hip screws with that of two Hansson hook-pins in 278 patients with fractures of the femoral neck. Background factors were similar in both groups. Follow-up was for two years. There were no significant differences between the groups in length of time of surgery, hospital stay, general complications, mortality, pain or walking ability. Likewise, the rates of early failure of fixation, nonunion, and the need for reoperation did not differ significantly between the groups. The use of hook-pins was associated with less drill penetrations of the femoral head during surgery (odds ratio 2.6, p= 0.05) and a lower incidence of necrosis of the femoral head (odds ratio 3.5, p = 0.04). There was a strong relationship between poor reduction and fixation of the fracture and subsequent reoperation (p = 0.0005 and p = 0.0001, respectively). Likewise, peroperative drill penetration of the femoral head was associated with a greater risk of reoperation (p = 0.038). Both methods gave favourable results. In total, 22% of the patients needed a major reoperation (usually hemiarthroplasty), while in 7% of the cases the fixation device needed to be removed. Osteosynthesis as the sole method for operation of all fractures of the femoral neck was thus successful in 78% of patients. With selective treatment most of the remaining patients would have benefited if treated by a primary arthroplasty. Accurate selection requires the development of better prognostic methods


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 1 | Pages 128 - 132
1 Jan 1996
Verhaar JAN Walenkamp GHIM van Mameren H Kester ADM van der Linden AJ

We performed a prospective, randomised trial on 106 patients to compare the effects of local corticosteroid injections with physiotherapy as advocated by Cyriax in the treatment of tennis elbow. The main outcome measures were the severity of pain, pain provoked by resisted dorsiflexion of the wrist, and patient satisfaction. At six weeks 22 of 53 patients in the injection group were free from pain compared with only three in the physiotherapy group. In the corticosteroid-treated group 26 patients had no pain on resisted dorsiflexion of the wrist compared with only three in the physiotherapy group. Thirty-five patients who had injections and 14 who had physiotherapy were satisfied with the outcome of treatment at six weeks. At the final assessment there were 18 excellent and 18 good results in the corticosteroid group and one excellent and 12 good results in the physiotherapy group. There was a significant increase in grip strength in both groups but those with injections had a significantly better result. After one year there were no significant differences between the two groups. Half of the patients, however, had received only the initial treatment, 20% had had combined therapy and 30% had had surgery. We conclude that at six weeks, treatment with corticosteroid injections was more effective than Cyriax physiotherapy and we recommend it because of its rapid action, reduction of pain and absence of side-effects


The Bone & Joint Journal
Vol. 98-B, Issue 12 | Pages 1620 - 1624
1 Dec 2016
Pailhé R Cognault J Massfelder J Sharma A Rouchy R Rubens-Duval B Saragaglia D

Aims. The role of high tibial osteotomy (HTO) is being questioned by the use of unicompartmental knee arthroplasty (UKA) in the treatment of medial compartment femorotibial osteoarthritis. Our aim was to compare the outcomes of revision HTO or UKA to a total knee arthroplasty (TKA) using computer-assisted surgery in matched groups of patients. Patients and Methods. We conducted a retrospective study to compare the clinical and radiological outcome of patients who underwent revision of a HTO to a TKA (group 1) with those who underwent revision of a medial UKA to a TKA (group 2). All revision procedures were performed using computer-assisted surgery. We extracted these groups of patients from our database. They were matched by age, gender, body mass index, follow-up and pre-operative functional score. The outcomes included the Knee Society Scores (KSS), radiological outcomes and the rate of further revision. Results. There were 20 knees in 20 patients in each group. The mean follow-up was 4.1 years (2 to 18.7). The mean total KSS at last follow-up was 185.7 (standard deviation (. sd. ) 5) in group 1 compared with 176.5 (. sd. 11) for group 2 (p = 0.003). The mean hip-knee-ankle angle was 180.2° (. sd. 3.2°) in group 1 and 179.0° (. sd. 2.2°) in group 2. No revision was required. Conclusion. We found that good functional and radiological outcomes followed revision of both HTO and UKA to TKA. Revision of HTO showed significantly better functional outcomes. These results need to be further investigated by a prospective randomised controlled trial involving a larger group of patients. Cite this article: Bone Joint J 2016;98-B:1620–4


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 4 | Pages 645 - 648
1 Jul 1995
Noordeen M Lavy C Shergill N Tuite J Jackson A

We studied 56 patients with fractures of the tibial shaft in a multicentre prospective randomised trial of three methods of external fixation. Group I was treated with a fixator which was unlocked at 4 to 6 weeks to allow free axial compression (axial dynamisation) with weight-bearing. Group II was treated with a fixator that was similarly unlocked at 4 to 6 weeks but included a small silicone spring which on weight-bearing could be compressed by up to 2 mm. this spring returns to its original length on cessation of weight-bearing thus allowing cycles of motion of up to 2 mm. Group III had a spring fixator like group II, but it was unlocked from the start to allow cyclical micromovement as soon as weight-bearing began. Fracture healing was monitored by the measurement of fracture stiffness. We defined healing as achieving a stiffness of 15 Nm per degree. The mean time was 14.1 weeks in group I, 15.9 weeks in group II, and 19.3 weeks in group III. The difference between groups was statistically significant (p = 0.004). The 95% confidence intervals for the average delay in healing with early cyclical micromovement (group III) as compared with later axial dynamisation (group I) was 1.8 to 8.7 weeks. The healing time in patients whose cyclical micromovement was delayed for 4 to 6 weeks (group II) was between these two extremes, but the differences from either of the other groups could have been due to patient selection. In the patients who completed the full trial, there were pin-track infections in over 60% of those in the cyclical micromovement groups compared with 20% in the axial dynamisation group (p = 0.03).(ABSTRACT TRUNCATED AT 250 WORDS)


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 4 | Pages 492 - 496
1 May 2002
Giannoudis PV Snowden S Matthews SJ Smye SW Smith RM

We have carried out a prospective, randomised trial to measure the rise of temperature during reaming of the tibia before intramedullary nailing. We studied 34 patients with a mean age of 35.1 years (18 to 63) and mean injury severity score of 10 (9 to 13). The patients were randomised into two groups: group 1 included 18 patients whose procedure was undertaken without a tourniquet and group 2, 16 patients in whom a tourniquet was used. The temperature in the bone was measured directly by two thermocouples inserted into the cortical bone near the isthmus of the tibial diaphysis. Reaming was carried out to at least 1.5 mm above the required diameter of the nail. Blood loss was assessed by recording the preoperative and postoperative haemoglobin (Hb) level. The minimum clinical follow-up was six months. In group 1 (no tourniquet), the mean Hb dropped 2.8 g/dl from 14.3 ± 1.02 g/dl to 11.5 ± 1.04 g/dl (p = 0.0001), whereas with the tourniquet, the mean decrease was 1.3 g/dl from 14 ± 1 g/dl to 12.7 ± 1.3 g/dl (p = 0.007). This difference was not statistically significant. The mean initial tibial temperature was 35.6°C (. sd. 0.6) and rose with reaming to levels between 36.3°C and 51.6°C. The highest temperatures were obtained with the largest reamers (11 and 12 mm, p = 0.0001) and the most rapid rise with the smallest diameters of medullary canal (8 or 9 mm). The rise of temperature was transient (20s). We were unable to identify any effect of the use of a tourniquet on the temperature achieved. Reamed intramedullary tibial nailing induces a transient elevation of temperature which is directly related to the amount of reaming


The Bone & Joint Journal
Vol. 97-B, Issue 9 | Pages 1250 - 1256
1 Sep 2015
Agrawal Y Russon K Chakrabarti I Kocheta A

Wrist block has been used to provide pain relief for many procedures on the hand and wrist but its role in arthroscopy of the wrist remains unexplored. Chondrotoxicity has been a concern with the intra-articular infiltration of local anaesthetic. We aimed to evaluate and compare the analgesic effect of portal and wrist joint infiltration with a wrist block on the pain experienced by patients after arthroscopy of the wrist. A prospective, randomised, double-blind trial was designed and patients undergoing arthroscopy of the wrist under general anaesthesia as a day case were recruited for the study. Levo-bupivacaine was used for both techniques. The effects were evaluated using a ten-point visual analogue scale, and the use of analgesic agents was also compared. The primary outcomes for statistical analyses were the mean pain scores and the use of analgesia post-operatively. . A total of 34 patients (63% females) were recruited to the portal and joint infiltration group and 32 patients (59% males) to the wrist block group. Mean age was 40.8 years in the first group and 39.7 years in the second group (p > 0.05). Both techniques provided effective pain relief in the first hour and 24 hours post-operatively but wrist block gave better pain scores at bedtime on the day of surgery (p = 0.007) and at 24 hours post-operatively (p = 0.006). . Wrist block provides better and more reliable analgesia in patients undergoing arthroscopy of the wrist without exposing patients to the risk of chondrotoxicity. Cite this article: Bone Joint J 2015;97-B:1250–6


Bone & Joint 360
Vol. 2, Issue 5 | Pages 8 - 12
1 Oct 2013
Phillips JRA

Not all questions can be answered by prospective randomised controlled trials. Registries were introduced as a way of collecting information on joint replacements at a population level. They have helped to identify failing implants and the data have also been used to monitor the performance of individual surgeons. This review aims to look at some of the less well known registries that are currently being used worldwide, including those kept on knee ligaments, ankle arthroplasty, fractures and trauma


Moderate to severe hallux valgus is conventionally treated by proximal metatarsal osteotomy. Several recent studies have shown that the indications for distal metatarsal osteotomy with a distal soft-tissue procedure could be extended to include moderate to severe hallux valgus. The purpose of this prospective randomised controlled trial was to compare the outcome of proximal and distal Chevron osteotomy in patients undergoing simultaneous bilateral correction of moderate to severe hallux valgus. The original study cohort consisted of 50 female patients (100 feet). Of these, four (8 feet) were excluded for lack of adequate follow-up, leaving 46 female patients (92 feet) in the study. The mean age of the patients was 53.8 years (30.1 to 62.1) and the mean duration of follow-up 40.2 months (24.1 to 80.5). After randomisation, patients underwent a proximal Chevron osteotomy on one foot and a distal Chevron osteotomy on the other. At follow-up, the American Orthopedic Foot and Ankle Society (AOFAS) hallux metatarsophalangeal interphalangeal (MTP-IP) score, patient satisfaction, post-operative complications, hallux valgus angle, first-second intermetatarsal angle, and tibial sesamoid position were similar in each group. Both procedures gave similar good clinical and radiological outcomes. This study suggests that distal Chevron osteotomy with a distal soft-tissue procedure is as effective and reliable a means of correcting moderate to severe hallux valgus as proximal Chevron osteotomy with a distal soft-tissue procedure. Cite this article: Bone Joint J 2015;97-B:202–7


Bone & Joint Research
Vol. 4, Issue 2 | Pages 11 - 16
1 Feb 2015
C. Wyatt M Wright T Locker J Stout K Chapple C Theis JC

Objectives. Effective analgesia after total knee arthroplasty (TKA) improves patient satisfaction, mobility and expedites discharge. This study assessed whether continuous femoral nerve infusion (CFNI) was superior to a single-shot femoral nerve block in primary TKA surgery completed under subarachnoid blockade including morphine. Methods. We performed an adequately powered, prospective, randomised, placebo-controlled trial comparing CFNI of 0.125% bupivacaine versus normal saline following a single-shot femoral nerve block and subarachnoid anaesthesia with intrathecal morphine for primary TKA. Patients were randomised to either treatment (CFNI 0 ml to 10 ml/h 0.125% bupivacaine) or placebo (CFNI 0 ml to 10 ml/h normal saline). Both groups received a single-shot femoral nerve block (0.25% 20 ml bupivacaine) prior to placement of femoral nerve catheter and subarachnoid anaesthesia with intrathecal morphine. All patients had a standardised analgesic protocol. The primary end point was post-operative visual analogue scale (VAS) pain score over 72 hours post-surgery. Secondary outcomes were morphine equivalent dose, range of movement, side effects, and length of stay. Results. A total of 86 patients were recruited. Treatment and placebo groups were comparable. No significant difference was found in VAS pain scores, total morphine equivalent requirements, side effects, range of movement, motor block, or length of hospital stay. Conclusion. No significant advantage was found for CFNI over a single-shot femoral block and subarachnoid anaesthesia after TKA. Cite this article: Bone Joint Res 2015;4:11–16


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1714 - 1714
1 Dec 2014
Haddad FS

Amin A, Watson A, Mangwani J, Nawabi DH, Ahluwalia R, Loeffler M. A prospective randomised controlled trial of autologous retransfusion in total knee replacement. Bone Joint J 2008;90-B:451–454


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 3 | Pages 404 - 408
1 Mar 2011
Harnett P Freeman R Harrison WJ Brown LC Beckles V

We conducted a prospective randomised controlled trial to compare the standard Ponseti plaster method with an accelerated method for the treatment of idiopathic congenital talipes equinovarus. The standard weekly plaster-change method was accelerated to three times per week. We hypothesised that both methods would be equally effective in achieving correction. A total of 40 consecutive patients (61 feet) were entered into the trial. The initial median Pirani score was 5.5 (95% confidence interval 4.5 to 6.0) in the accelerated group and 5.0 (95% confidence interval 4.0 to 5.0) in the standard control group. The scores decreased by an average 4.5 in the accelerated group and 4.0 in the control group. There was no significant difference in the final Pirani score between the two groups (chi-squared test, p = 0.308). The median number of treatment days in plaster was 16 in the accelerated group and 42 in the control group (p < 0.001). Of the 19 patients in the accelerated group, three required plaster treatment for more than 21 days and were then assigned to the standard control method. Of the 40 patients, 36 were followed for a minimum of six months. These results suggest that comparable outcomes can be achieved with an accelerated Ponseti method. The ability to complete all necessary manipulations within a three-week period facilitates treatment where patients have to travel long distances


The Bone & Joint Journal
Vol. 99-B, Issue 11 | Pages 1520 - 1525
1 Nov 2017
Haines N Kempton LB Seymour RB Bosse MJ Churchill C Hand K Hsu JR Keil D Kellam J Rozario N Sims S Karunakar MA

Aims. To evaluate the effect of a single early high-dose vitamin D supplement on fracture union in patients with hypovitaminosis D and a long bone fracture. Patients and Methods. Between July 2011 and August 2013, 113 adults with a long bone fracture were enrolled in a prospective randomised double-blind placebo-controlled trial. Their serum vitamin D levels were measured and a total of 100 patients were found to be vitamin D deficient (< 20 ng/ml) or insufficient (< 30 ng/mL). These were then randomised to receive a single dose of vitamin D. 3. orally (100 000 IU) within two weeks of injury (treatment group, n = 50) or a placebo (control group, n = 50). We recorded patient demographics, fracture location and treatment, vitamin D level, time to fracture union and complications, including vitamin D toxicity. Outcomes included union, nonunion or complication requiring an early, unplanned secondary procedure. Patients without an outcome at 15 months and no scheduled follow-up were considered lost to follow-up. The t-test and cross tabulations verified the adequacy of randomisation. An intention-to-treat analysis was carried out. Results. In all, 100 (89%) patients had hypovitaminosis D. Both treatment and control groups had similar demographics and injury characteristics. The initial median vitamin D levels were 16 ng/mL (interquartile range 5 to 28) in both groups (p = 0.885). A total of 14 patients were lost to follow-up (seven from each group), two had fixation failure (one in each group) and one control group patient developed an infection. Overall, the nonunion rate was 4% (two per group). No patient showed signs of clinical toxicity from their supplement. Conclusions. Despite finding a high level of hypovitaminosis D, the rate of union was high and independent of supplementation with vitamin D. 3. . Cite this article: Bone Joint J 2017;99-B:1520–5


Bone & Joint Research
Vol. 6, Issue 7 | Pages 423 - 432
1 Jul 2017
van der Stok J Hartholt KA Schoenmakers DAL Arts JJC

Objectives. The aim of this systematic literature review was to assess the clinical level of evidence of commercially available demineralised bone matrix (DBM) products for their use in trauma and orthopaedic related surgery. Methods. A total of 17 DBM products were used as search terms in two available databases: Embase and PubMed according to the Preferred Reporting Items for Systematic Reviews and Meta Analyses statement. All articles that reported the clinical use of a DBM-product in trauma and orthopaedic related surgery were included. Results. The literature search resulted in 823 manuscripts of which 64 manuscripts met the final inclusion criteria. The included manuscripts consisted of four randomised controlled trials (level I), eight cohort studies (level III) and 49 case-series (level IV). No clinical studies were found for ten DBM products, and most DBM products were only used in combination with other grafting materials. DBM products were most extensively investigated in spinal surgery, showing limited level I evidence that supports the use Grafton DBM (Osteotech, Eatontown, New Jersey) as a bone graft extender in posterolateral lumbar fusion surgery. DBM products are not thoroughly investigated in trauma surgery, showing mainly level IV evidence that supports the use of Allomatrix (Wright Medical, London, United Kingdom), DBX (DePuy Synthes, Zuchwil, Switzerland), Grafton DBM, or OrthoBlast (Citagenix Laval, Canada) as bone graft extenders. Conclusions. The clinical level of evidence that supports the use of DBM in trauma and orthopaedic surgery is limited and consists mainly of poor quality and retrospective case-series. More prospective, randomised controlled trials are needed to understand the clinical effect and impact of DBM in trauma and orthopaedic surgery. Cite this article: J. van der Stok, K. A. Hartholt, D. A. L. Schoenmakers, J. J. C. Arts. The available evidence on demineralised bone matrix in trauma and orthopaedic surgery: A systemati c review. Bone Joint Res 2017;6:423–432. DOI: 10.1302/2046-3758.67.BJR-2017-0027.R1


The Bone & Joint Journal
Vol. 98-B, Issue 6 | Pages 786 - 792
1 Jun 2016
Schotanus MGM Sollie R van Haaren EH Hendrickx RPM Jansen EJP Kort NP

Aims. This prospective randomised controlled trial was designed to evaluate the outcome of both the MRI- and CT-based patient-specific matched guides (PSG) from the same manufacturer. Patients and Methods. A total of 137 knees in 137 patients (50 men, 87 women) were included, 67 in the MRI- and 70 in the CT-based PSG group. Their mean age was 68.4 years (47.0 to 88.9). Outcome was expressed as the biomechanical limb alignment (centre hip-knee-ankle: HKA-axis) achieved post-operatively, the position of the individual components within 3° of the pre-operatively planned alignment, correct planned implant size and operative data (e.g. operating time and blood loss). Results. The patient demographics (e.g. age, body mass index), correct planned implant size and operative data were not significantly different between the two groups. The proportion of outliers in the coronal and sagittal plane ranged from 0% to 21% in both groups. Only the number of outliers for the posterior slope of the tibial component showed a significant difference (p = 0.004) with more outliers in the CT group (n = 9, 13%) than in the MRI group (0%). . Conclusion. The post-operative HKA-axis was comparable in the MRI- and CT-based PSGs, but there were significantly more outliers for the posterior slope in the CT-based PSGs. Take home message: Alignment with MRI-based PSG is at least as good as, if not better, than that of the CT-based PSG, and is the preferred imaging modality when performing TKA with use of PSG. Cite this article: Bone Joint J 2016;98-B:786–92


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 7 | Pages 907 - 913
1 Jul 2011
Ward TR Burns AW Gillespie MJ Scarvell JM Smith PN

Bicruciate-stabilised total knee replacement (TKR) aims to restore normal kinematics by replicating the function of both cruciate ligaments. We performed a prospective, randomised controlled trial in which bicruciate- and posterior-stabilised TKRs were implanted in 13 and 15 osteo-arthritic knees, respectively. The mean age of the bicruciate-stabilised group was 63.9 years (. sd. 10.00) and that of the posterior-stabilised group 63.2 years (. sd. 6.7). A control group comprised 14 normal subjects with a mean age of 67.9 years (. sd. 7.9). The patellar tendon angle (PTA) was measured one week pre-operatively and at seven weeks post-operatively during knee extension, flexion and step-up exercises. At near full extension during step-up, the bicruciate-stabilised TKR produced a higher mean PTA than the posterior-stabilised TKR, indicating that the bicruciate design at least partially restored the kinematic role of the anterior cruciate ligament. The bicruciate-stabilised TKR largely restored the pre-operative kinematics, whereas the posterior-stabilised TKR resulted in a consistently lower PTA at all activities. The PTA in the pre-operative knees was higher than in the control group during the step-up and at near full knee extension. Overall, both groups generated a more normal PTA than that seen in previous studies in high knee flexion. This suggested that both designs of TKR were more effective at replicating the kinematic role of the posterior cruciate ligament than those used in previous studies


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 2 | Pages 188 - 197
1 Feb 2006
Cobb J Henckel J Gomes P Harris S Jakopec M Rodriguez F Barrett A Davies B

We performed a prospective, randomised controlled trial of unicompartmental knee arthroplasty comparing the performance of the Acrobot system with conventional surgery. A total of 27 patients (28 knees) awaiting unicompartmental knee arthroplasty were randomly allocated to have the operation performed conventionally or with the assistance of the Acrobot. The primary outcome measurement was the angle of tibiofemoral alignment in the coronal plane, measured by CT. Other secondary parameters were evaluated and are reported. All of the Acrobot group had tibiofemoral alignment in the coronal plane within 2° of the planned position, while only 40% of the conventional group achieved this level of accuracy. While the operations took longer, no adverse effects were noted, and there was a trend towards improvement in performance with increasing accuracy based on the Western Ontario and McMaster Universities Osteoarthritis Index and American Knee Society scores at six weeks and three months. The Acrobot device allows the surgeon to reproduce a pre-operative plan more reliably than is possible using conventional techniques which may have clinical advantages


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 3 | Pages 298 - 303
1 Mar 2006
Bhan S Pankaj A Malhotra R

We compared the safety and outcome of one-stage bilateral total hip arthroplasty with those of a two-stage procedure during different admissions in a prospective, randomised controlled trial in an Asian population. Of 168 patients included in the study, 83 had a single- and 85 a two-stage procedure. Most of the patients (59.9%) suffered from inflammatory arthritis. The intra-operative complications, early systemic complications, the operating time, positioning of the components, the functional score, restoration of limb length and survival rates at 96 months were similar in the two groups. The total estimated blood loss was significantly lower in patients undergoing a one-stage procedure than in patients who had a two-stage procedure, but the transfusion requirements were significantly higher in the former group (p = 0.001). The hospital stay was significantly shorter in the one-stage group, 7.25 days (. sd. 1.30; 5 to 20) compared with 10 days (. sd. 1.65; 8 to 24) in the two-stage group (p = 0.023). We believe that a one-stage procedure is safe and appropriate in our population


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1514 - 1520
1 Nov 2013
D’Agostino P Barbier O

The osteoinductive properties of demineralised bone matrix have been demonstrated in animal studies. However, its therapeutic efficacy has yet to be proven in humans. The clinical properties of AlloMatrix, an injectable calcium-based demineralised bone matrix allograft, were studied in a prospective randomised study of 50 patients with an isolated unstable distal radial fracture treated by reduction and Kirschner (K-) wire fixation. A total of 24 patients were randomised to the graft group (13 men and 11 women, mean age 42.3 years (20 to 62)) and 26 to the no graft group (8 men and 18 women, mean age 45.0 years (17 to 69)). At one, three, six and nine weeks, and six and 12 months post-operatively, patients underwent radiological evaluation, assessments for range of movement, grip and pinch strength, and also completed the Disabilities of Arm, Shoulder and Hand questionnaire. At one and six weeks and one year post-operatively, bone mineral density evaluations of both wrists were performed. No significant difference in wrist function and speed of recovery, rate of union, complications or bone mineral density was found between the two groups. The operating time was significantly higher in the graft group (p = 0.004). Radiologically, the reduction parameters remained similar in the two groups and all AlloMatrix extraosseous leakages disappeared after nine weeks. This prospective randomised controlled trial did not demonstrate a beneficial effect of AlloMatrix demineralised bone matrix in the treatment of this category of distal radial fractures treated by K-wire fixation. Cite this article: Bone Joint J 2013;95-B:1514–20


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 1 | Pages 110 - 114
1 Jan 1996
Butt MS Krikler SJ Ali MS

We performed a prospective, randomised controlled trial of the operative versus non-operative treatment of 42 displaced fractures of the distal femur in elderly patients. Excellent or good results were achieved in 53% of the operated group and in 31% of the non-operated group. There were more complications in the latter, and the time to discharge was considerably longer


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 1 | Pages 45 - 49
1 Jan 1992
Fordyce M Ling R

In a prospective, randomised controlled trial, the efficacy of the A-V Impulse System in the prevention of deep-vein thrombosis was investigated in 84 patients who had undergone total hip replacement. The incidence of venographically proven, and clinically significant postoperative deep-vein thrombosis was 40% in the control group and 5% in the treatment group (p less than 0.001). No adverse reactions were recorded


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 8 | Pages 1045 - 1048
1 Aug 2011
Avery PP Baker RP Walton MJ Rooker JC Squires B Gargan MF Bannister GC

We reviewed the seven- to ten-year results of our previously reported prospective randomised controlled trial comparing total hip replacement and hemiarthroplasty for the treatment of displaced intracapsular fracture of the femoral neck. Of our original study group of 81 patients, 47 were still alive. After a mean follow up of nine years (7 to 10) overall mortality was 32.5% and 51.2% after total hip replacement and hemiarthroplasty, respectively (p = 0.09). At 100 months postoperatively a significantly greater proportion of hemiarthroplasty patients had died (p = 0.026). Three hips dislocated following total hip replacement and none after hemiarthroplasty. In both the total hip replacement and hemiarthroplasty groups a deterioration had occurred in walking distance (p = 0.02 and p < 0.001, respectively). One total hip replacement required revision compared with four hemiarthroplasties which were revised to total hip replacements. All surviving patients with a total hip replacement demonstrated wear of the cemented polyethylene component and all hemiarthroplasties had produced acetabular erosion. There was lower mortality (p = 0.013) and a trend towards superior function in patients with a total hip replacement in the medium term


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 6 | Pages 787 - 792
1 Jun 2012
Thomsen MG Husted H Bencke J Curtis D Holm G Troelsen A

The purpose of this study was to investigate whether a gender-specific high-flexion posterior-stabilised (PS) total knee replacement (TKR) would offer advantages over a high-flex PS TKR regarding range of movement (ROM), ‘feel’ of the knee, pain and satisfaction, as well as during activity. A total of 24 female patients with bilateral osteoarthritis entered this prospective, blind randomised trial in which they received a high-flex PS TKR in one knee and a gender-specific high-flexion PS TKR in the other knee. At follow-up, patients were assessed clinically measuring ROM, and questioned about pain, satisfaction and daily ‘feel’ of each knee. Patients underwent gait analysis pre-operatively and at one year, which yielded kinematic, kinetic and temporospatial parameters indicative of knee function during gait. At final follow-up we found no statistically significant differences in ROM (p = 0.82). The median pain score was 0 (0 to 8) in both groups (p = 0.95). The median satisfaction score was 9 (4 to 10) in the high-flex group and 8 (0 to 10) in the gender-specific group (p = 0.98). The median ‘feel’ score was 9 (3 to 10) in the high-flex group and 8 (0 to 10) in the gender-specific group (p = 0.66). Gait analysis showed no statistically significant differences between the two prosthetic designs in any kinematic, kinetic or temporospatial parameters. Both designs produced good clinical results with significant improvements in several gait parameters without evidence of any advantage in the gender-specific design


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 116 - 122
1 Jan 2010
Parker MI Pryor G Gurusamy K

We undertook a prospective randomised controlled trial involving 400 patients with a displaced intracapsular fracture of the hip to determine whether there was any difference in outcome between treatment with a cemented Thompson hemiarthroplasty and an uncemented Austin-Moore prosthesis. The surviving patients were followed up for between two and five years by a nurse blinded to the type of prosthesis used. The mean age of the patients was 83 years (61 to 104) and 308 (77%) were women. The degree of residual pain was less in those treated with a cemented prosthesis (p < 0.0001) three months after surgery. Regaining mobility was better in those treated with a cemented implant (p = 0.005) at six months after operation. No statistically significant difference was found between the two groups with regard to mortality, implant-related complications, re-operations or post-operative medical complications. The use of a cemented Thompson hemiarthroplasty resulted in less pain and less deterioration in mobility than an uncemented Austin-Moore prosthesis with no increase in complications


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 352 - 355
1 Mar 2005
Wilson-MacDonald J Burt G Griffin D Glynn C

We have assessed whether an epidural steroid injection is effective in the treatment of symptoms due to compression of a nerve root in the lumbar spine by carrying out a prospective, randomised, controlled trial in which patients received either an epidural steroid injection or an intramuscular injection of local anaesthetic and steroid. We assessed a total of 93 patients according to the Oxford pain chart and the Oswestry disability index and followed up for a minimum of two years. All the patients had been categorised as potential candidates for surgery. There was a significant reduction in pain early on in those having an epidural steroid injection but no difference in the long term between the two groups. The rate of subsequent operation in the groups was similar


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 2 | Pages 238 - 242
1 Feb 2006
Khan RJK Fick D Yao F Tang K Hurworth M Nivbrant B Wood D

We carried out a blinded prospective randomised controlled trial comparing 2-octylcyanoacrylate (OCA), subcuticular suture (monocryl) and skin staples for skin closure following total hip and total knee arthroplasty. We included 102 hip replacements and 85 of the knee. OCA was associated with less wound discharge in the first 24 hours for both the hip and the knee. However, with total knee replacement there was a trend for a more prolonged wound discharge with OCA. With total hip replacement there was no significant difference between the groups for either early or late complications. Closure of the wound with skin staples was significantly faster than with OCA or suture. There was no significant difference in the length of stay in hospital, Hollander wound evaluation score (cosmesis) or patient satisfaction between the groups at six weeks for either hips or knees. We consider that skin staples are the skin closure of choice for both hip and knee replacements


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 1 | Pages 68 - 73
1 Jan 1989
Howard P Stewart H Hind R Burke F

We report a prospective, randomised, controlled trial of 50 severely displaced comminuted Colles' fractures treated by either external fixation or manipulation and plaster. Each patient was assessed radiographically throughout treatment, and functionally by an independent observer at three and six months. The functional result correlated with the anatomical result, which was significantly better in patients treated by external fixation. This resulted in significantly improved function especially in young patients, and also a lower complication rate. We recommend the use of external fixation for young patients with comminuted displaced Colles' fractures unless manipulation and plaster show excellent reduction


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 1 | Pages 50 - 52
1 Jan 1992
Wilson N Das S Kakkar V Maurice H Smibert J Thomas E Nixon J

We performed a prospective randomised controlled trial of a new mechanical method of prophylaxis for venous thrombo-embolism in 60 patients undergoing knee replacement surgery. The method uses the A-V Impulse System to produce cyclical compression of the venous reservoir of the foot. The overall incidence of deep-vein thrombosis was 68.7% in patients receiving no prophylaxis and 50% in those using the device. The difference was not significant. There was, however, a reduction of the extent of thrombosis in the treated group. There were 13 major calf-vein thrombi and six proximal-vein thrombi in the control group compared with only five major calf-vein thrombi in the treated group. This difference was significant (p = 0.014). No patient developed clinical features of a pulmonary embolism


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 5 | Pages 775 - 778
1 Sep 1992
Stranks G MacKenzie N Grover M Fail T

We performed a prospective randomised controlled trial of the A-V Impulse System in 82 patients treated by hemiarthroplasty for subcapital fracture of the femoral neck. The incidence of proximal deep-vein thrombosis as assessed by Doppler ultrasonography was 23% in the control group and 0% in those using the device (p less than 0.01). Calf and thigh circumferences were measured in both groups at seven to ten days after operation. In the treatment group there was a mean relative reduction of postoperative swelling of the thigh by 3.27 cm (p less than 0.001) and of the calf by 1.55 cm (p less than 0.001). The A-V Impulse System appears to be a safe and effective method of reducing the incidence of proximal deep-vein thrombosis, and of postoperative swelling


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 2 | Pages 307 - 311
1 Mar 1991
Roumen R Hesp W Bruggink E

We report the results of a prospective randomised controlled trial of the management of 101 Colles' fractures in patients over the age of 55 years. Within two weeks of initial reduction 43 fractures had displaced with either more than 10 degrees dorsal angulation or more than 5 mm radial shortening. These patients were randomly divided into two groups: 21 were remanipulated and held by an external fixator; in the control group of 22 patients, the redisplacement was accepted and conservative treatment was continued. Patients treated with external fixation had a good anatomical result, but their function was no better than that of the control group. We found no correlation between final anatomical and functional outcome, and concluded that the severity of the original soft-tissue injury and its complications are the major determinants of functional end result


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 5 | Pages 701 - 704
1 Jul 2004
Dunkow PD Jatti M Muddu BN

We conducted a prospective, randomised, controlled trial of 45 patients (47 elbows), with tennis elbow, who underwent either a formal open release or a percutaneous tenotomy. All patients had pre- and post-operative assessment using the Disability of Arm, Shoulder and Hand (DASH) scoring system. Both groups were followed up for a minimum of 12 months. Statistical analyses using the Mann-Whitney U test and repeated measured ANOVA showed significant improvements for patient satisfaction (p = 0.012), time to return to work (p = 0.0001), improvements in DASH score (p = 0.001) and improvement in sporting activities (p = 0.046) in the percutaneous group. Those patients undergoing a percutaneous release returned to work on average three weeks earlier and improved significantly more quickly than those undergoing an open procedure. The percutaneous procedure is a quicker and simpler procedure to undertake and produces significantly better results


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 3 | Pages 413 - 417
1 Apr 2002
McLauchlan GJ Cowan B Annan IH Robb JE

In a prospective, randomised controlled trial, 68 children who had a completely displaced metaphyseal fracture of the distal radius were treated either by manipulation (MUA) and application of an above-elbow cast alone or by the additional insertion of a percutaneous Kirschner (K-) wire. Full radiological follow-up to union was obtained in 65 children and 56 returned for clinical evaluation three months after injury. Maintenance of reduction was significantly better in the K-wire group and fewer follow-up radiographs were required. There was no significant difference in the clinical outcome measured three months after injury. Seven of 33 patients in the MUA group had to undergo a second procedure because of an unacceptable position compared with none of the 35 in the K-wire group (chi-squared test, p < 0.01). One patient in the K-wire group required exploration for recovery of a migrated wire. We conclude that the use of a percutaneous K-wire to augment the reduction of the fracture in children who have a completely displaced metaphyseal fracture of the distal radius is a safe and reliable way of maintaining alignment of the fracture


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 4 | Pages 550 - 554
1 Jul 1996
Hui ACW Heras-Palou C Dunn I Triffitt PD Crozier A Imeson J Gregg PJ

We performed a prospective, randomised controlled trial in 177 patients who were having either total hip or knee replacement, to evaluate the use of both above- and below-knee graded compression stockings in the prevention of deep-vein thrombosis (DVT). With above-knee stockings, we found no significant reduction of the overall, proximal or major calf (> 5 cm) DVT rates. With below-knee stockings, the overall thrombosis rate was similar to that of the control group but the stockings appeared to have altered the pattern of thrombosis. Patients who had total hip replacement and wore below-knee stockings had a significantly higher rate of proximal or major calf DVT (p = 0.03). This pattern was reversed in patients with total knee replacement who developed a significantly lower rate of proximal or major calf DVT with below-knee stockings (p < 0.05). Our results showed that, with the exception of below-knee stockings in knee replacement patients, graded compression stockings were ineffective in preventing DVT after hip or knee replacement surgery


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 153 - 156
1 Nov 2012
Su EP Perna M Boettner F Mayman DJ Gerlinger T Barsoum W Randolph J Lee G

Pain, swelling and inflammation are expected during the recovery from total knee arthroplasty (TKA) surgery. The severity of these factors and how a patient copes with them may determine the ultimate outcome of a TKA. Cryotherapy and compression are frequently used modalities to mitigate these commonly experienced sequelae. However, their effect on range of motion, functional testing, and narcotic consumption has not been well-studied. A prospective, multi-center, randomised trial was conducted to evaluate the effect of a cryopneumatic device on post-operative TKA recovery. Patients were randomised to treatment with a cryopneumatic device or ice with static compression. A total of 280 patients were enrolled at 11 international sites. Both treatments were initiated within three hours post-operation and used at least four times per day for two weeks. The cryopneumatic device was titrated for cooling and pressure by the patient to their comfort level. Patients were evaluated by physical therapists blinded to the treatment arm. Range of motion (ROM), knee girth, six minute walk test (6MWT) and timed up and go test (TUG) were measured pre-operatively, two- and six-weeks post-operatively. A visual analog pain score and narcotic consumption was also measured post-operatively. At two weeks post-operatively, both the treatment and control groups had diminished ROM and function compared to pre-operatively. Both groups had increased knee girth compared to pre- operatively. There was no significant difference in ROM, 6MWT, TUG, or knee girth between the 2 groups. We did find a significantly lower amount of narcotic consumption (509 mg morphine equivalents) in the treatment group compared with the control group (680 mg morphine equivalents) at up to two weeks postop, when the cryopneumatic device was being used (p < 0.05). Between two and six weeks, there was no difference in the total amount of narcotics consumed between the two groups. At six weeks, there was a trend toward a greater distance walked in the 6MWT in the treatment group (29.4 meters versus 7.9 meters, p = 0.13). There was a significant difference in the satisfaction scores of patients with their cooling regimen, with greater satisfaction in the treatment group (p < 0.0001). There was no difference in ROM, TUG, VAS, or knee girth at six weeks. There was no difference in adverse events or compliance between the two groups. A cryopneumatic device used after TKA appeared to decrease the need for narcotic medication from hospital discharge to 2 weeks post-operatively. There was also a trend toward a greater distance walked in the 6MWT. Patient satisfaction with the cryopneumatic cooling regimen was significantly higher than with the control treatment.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 4 | Pages 501 - 507
1 Apr 2005
Krasny C Enenkel M Aigner N Wlk M Landsiedl F

We carried out a prospective, randomised controlled trial on two groups of 40 patients with painful calcific tendonitis and a mean age of 48.4 years (32.5 to 67.3). All were to undergo arthroscopic removal of the calcific deposit within six months after randomisation. The 40 patients in group I received ultrasound-guided needling followed by high-energy shock-wave therapy and the 40 in group II had shock-wave therapy alone. In both groups one treatment consisting of 2500 impulses of shock waves with an energy flux density of 0.36 mJ/mm. 2. was applied. The clinical and radiological outcome was assessed using the 100-point Constant shoulder scoring system and standardised radiographs. The mean follow-up was 4.1 months and no patient was lost to follow-up. Both groups had significant improvement in their Constant shoulder score. Radiographs showed disappearance of the calcific deposit in 60.0% of the shoulders in group I and in 32.5% of group II (p < 0.05). Significantly better clinical and radiological results were obtained in group I than in group II. Arthroscopic removal of the deposit was avoided in 32 patients of group I and in 22 of group II. No severe side-effects were recorded. Ultrasound-guided needling in combination with high-energy shock-wave therapy is more effective than shock-wave therapy alone in patients with symptomatic calcific tendonitis, giving significantly higher rates of elimination of the calcium deposits, better clinical results and reduction in the need for surgery


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1454 - 1459
1 Nov 2006
Brouwer RW Bierma-Zeinstra SMA van Raaij TM Verhaar JAN

A prospective, randomised, controlled trial compared two different techniques of high tibial osteotomy with a lateral closing wedge or a medial opening wedge, stabilised by a Puddu plate. The clinical outcome and radiological results were examined at one year. The primary outcome measure was the achievement of an overcorrection of valgus of 4°. Secondary outcome measures were the severity of pain (visual analogue scale), knee function (Hospital for Special Surgery score), and walking distance. Between January 2001 and April 2004, 92 patients were randomised to one or other of the techniques. At follow-up at one year the post-operative hip-knee-ankle angle was 3.4° (± 3.6° . sd. ) valgus after a closing wedge and 1.3° (± 4.7° . sd. ) of valgus after an opening wedge. The adjusted mean difference of 2.1° was significant (p = 0.02). The deviation from 4° of valgus alignment was 2.7° (± 2.4° . sd. ) in the closing wedge and 4.0° (± 3.6° . sd. ) in the opening-wedge groups. The adjusted mean difference of 1.67° was also significant (p = 0.01). The severity of pain, knee score and walking ability improved in both groups, but the difference was not significant. Because of pain, the staples required removal in 11 (23%) patients in the closing-wedge group and a Puddu plate was removed in 27 (60%) patients in the opening-wedge group. This difference was significant (p < 0.001). We conclude that closing-wedge osteotomy achieves a more accurate correction with less morbidity, although both techniques had improved the function of the knee at one year after the procedure


The Bone & Joint Journal
Vol. 102-B, Issue 5 | Pages 606 - 610
1 May 2020
Nicholson JA Slader B Martindale A Mckie S Robinson CM

Aims

The primary aim of this study was to evaluate the efficacy of distension arthrography in the treatment of adhesive capsulitis of the shoulder. The secondary aim was to assess which patient and procedural factors predicted the recurrence of symptoms after the procedure.

Methods

All patients referred to our shoulder clinic over a ten-year period, between 2008 and 2018, with a clinical diagnosis of capsulitis and symptoms persisting for more than six months, were offered treatment with a distension arthrogram. All procedures were performed by one of five musculoskeletal radiologists, with a combination of steroid, local anaesthetic, and a distention volume of 10 ml, 30 ml, or 50 ml. Patient demographics, procedural details, recurrence of symptoms, and the need for further intervention were evaluated.


Bone & Joint 360
Vol. 6, Issue 6 | Pages 25 - 28
1 Dec 2017


Bone & Joint 360
Vol. 6, Issue 5 | Pages 27 - 30
1 Oct 2017


Bone & Joint 360
Vol. 4, Issue 4 | Pages 2 - 7
1 Aug 2015
Nicol S Jackson M Monsell F

This review explores recent advances in fixator design and used in contemporary orthopaedic practice including the management of bone loss, complex deformity and severe isolated limb injury.


The Bone & Joint Journal
Vol. 99-B, Issue 10 | Pages 1267 - 1279
1 Oct 2017
Chughtai M Piuzzi NS Khlopas A Jones LC Goodman SB Mont MA

Non-traumatic osteonecrosis of the femoral head is a potentially devastating condition, the prevalence of which is increasing. Many joint-preserving forms of treatment, both medical and surgical, have been developed in an attempt to slow or reverse its progression, as it usually affects young patients.

However, it is important to evaluate the best evidence that is available for the many forms of treatment considering the variation in the demographics of the patients, the methodology and the outcomes in the studies that have been published, so that it can be used effectively.

The purpose of this review, therefore, was to provide an up-to-date, evidence-based guide to the management, both non-operative and operative, of non-traumatic osteonecrosis of the femoral head.

Cite this article: Bone Joint J 2017;99-B:1267–79.


The Bone & Joint Journal
Vol. 98-B, Issue 10 | Pages 1299 - 1311
1 Oct 2016
Hong CC Pearce CJ Ballal MS Calder JDF

Injuries to the foot in athletes are often subtle and can lead to a substantial loss of function if not diagnosed and treated appropriately. For these injuries in general, even after a diagnosis is made, treatment options are controversial and become even more so in high level athletes where limiting the time away from training and competition is a significant consideration.

In this review, we cover some of the common and important sporting injuries affecting the foot including updates on their management and outcomes.

Cite this article: Bone Joint J 2016;98-B:1299–1311.


Bone & Joint 360
Vol. 5, Issue 6 | Pages 21 - 24
1 Dec 2016


The Bone & Joint Journal
Vol. 98-B, Issue 9 | Pages 1197 - 1201
1 Sep 2016
Ashman BD Kong C Wing KJ Penner MJ Bugler KE White TO Younger ASE

Aims

Patients with diabetes are at increased risk of wound complications after open reduction and internal fixation of unstable ankle fractures. A fibular nail avoids large surgical incisions and allows anatomical reduction of the mortise.

Patients and Methods

We retrospectively reviewed the results of fluoroscopy-guided reduction and percutaneous fibular nail fixation for unstable Weber type B or C fractures in 24 adult patients with type 1 or type 2 diabetes. The re-operation rate for wound dehiscence or other indications such as amputation, mortality and functional outcomes was determined.


The Bone & Joint Journal
Vol. 98-B, Issue 7 | Pages 984 - 989
1 Jul 2016
Zijlmans JL Buis DR Verbaan D Vandertop WP

Aims

Our aim was to perform a systematic review of the literature to assess the incidence of post-operative epidural haematomas and wound infections after one-, or two-level, non-complex, lumbar surgery for degenerative disease in patients with, or without post-operative wound drainage.

Patients and Methods

Studies were identified from PubMed and EMBASE, up to and including 27 August 2015, for papers describing one- or two-level lumbar discectomy and/or laminectomy for degenerative disease in adults which reported any form of subcutaneous or subfascial drainage.


Bone & Joint 360
Vol. 6, Issue 4 | Pages 20 - 22
1 Aug 2017


Bone & Joint 360
Vol. 4, Issue 3 | Pages 12 - 14
1 Jun 2015

The June 2015 Knee Roundup360 looks at: Cruciate substituting versus retaining knee replacement; What’s behind the psychology of anterior cruciate ligament (ACL) reconstruction?; Is there a difference in total knee arthroplasty risk of revision in highly crosslinked versus conventional polyethylene?; Unicompartmental knee arthroplasty: is age the missing variable?; Satisfaction rates following total knee arthroplasty; Is knee alignment dynamic?; Unicompartmental knee arthroplasty: cemented or cementless?; Can revision knee services pay?


Bone & Joint Research
Vol. 5, Issue 5 | Pages 185 - 190
1 May 2016
Yuenyongviwat V Iamthanaporn K Hongnaparak T Tangtrakulwanich B

Objectives

Nylon sutures and skin staples are used commonly in total knee arthroplasty (TKA) surgical wound closure. However, there is no study that compares the wound healing efficacy and patient satisfaction scores of both techniques in the same knee.

Methods

We randomised 70 patients who underwent primary TKA into two groups. In one group of 34 patients, the skin at the upper half of the wound was closed with skin staples and the lower half of the wound was closed with simple interrupted nylon sutures. In the other group of 36 patients, the skin at the upper half of the wound was closed with nylon stitches and the lower half of the wound was closed with skin staples. We recorded the wound closure time, pain score at the time of stitch removal, wound complication rate, patient satisfaction score, and the Hollander wound evaluation score at the post-operative periods of five days, 14 days, six weeks, three months, and six months. Each half wound was analysed separately.


Bone & Joint Research
Vol. 6, Issue 8 | Pages 506 - 513
1 Aug 2017
Sims AL Farrier AJ Reed MR Sheldon TA

Objectives

The objective of this study was to assess all evidence comparing the Thompson monoblock hemiarthroplasty with modular unipolar implants for patients requiring hemiarthroplasty of the hip with respect to mortality and complications.

Methods

A literature search was performed to identify all relevant literature. The population consisted of patients undergoing hemiarthroplasty of the hip for fracture. The intervention was hemiarthroplasty of the hip with a comparison between Thompson and modular unipolar prostheses.

Pubmed, Embase, CINAHL, Web of Science, PROSPERO and the Cochrane Central Register of Controlled Trials.

The study designs included were randomised controlled trials (RCTs), well designed case control studies and retrospective or prospective cohort studies. Studies available in any language, published at any time until September 2015 were considered. Studies were included if they contained mortality or complications.


Bone & Joint 360
Vol. 6, Issue 2 | Pages 23 - 25
1 Apr 2017


Bone & Joint 360
Vol. 4, Issue 5 | Pages 32 - 33
1 Oct 2015
Das A


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 799 - 805
1 Jun 2017
Ketola S Lehtinen JT Arnala I

Aims

Rotator cuff tendinopathy has a multifactorial origin. Rejecting the mechanistic theory has also led to abandoning operative treatment at initial presentation in the first line. Physiotherapy exercise programmes are the accepted first line treatment. The aim of this study was to assess the long-term additional benefits of subacromial decompression in the treatment of rotator cuff tendinopathy.

Patients and Methods

This randomised controlled trial of 140 patients (52 men, 88 women, mean age 47.1 years; 18 to 60) with rotator cuff tendinopathy extended previous work up to a maximum of 13 years. The patients were randomised into two treatment groups: arthroscopic acromioplasty and a supervised exercise treatment and a similar supervised exercise treatment alone. Self-reported pain on a visual analogue scale (VAS) was the primary outcome measure. Secondary measures were disability, working ability, pain at night, Shoulder Disability Questionnaire score and the number of painful days during the three months preceding the final assessment.


Bone & Joint 360
Vol. 6, Issue 2 | Pages 28 - 30
1 Apr 2017


The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 245 - 249
1 Feb 2017
Barnes LAF Kim HM Caldwell J Buza J Ahmad CS Bigliani LU Levine WN

Aims

Advances in arthroscopic techniques for rotator cuff repair have made the mini-open approach less popular. However, the mini-open approach remains an important technique for repair for many surgeons. The aims of this study were to compare the integrity of the repair, the function of the shoulder and satisfaction post-operatively using these two techniques in patients aged > 50 years.

Patients and Methods

We identified 22 patients treated with mini-open and 128 patients treated with arthroscopic rotator cuff repair of July 2007 and June 2011. The mean follow-up was two years (1 to 5). Outcome was assessed using the American Shoulder and Elbow Surgeons (ASES) and Simple Shoulder Test (SST) scores, and satisfaction. The integrity of the repair was assessed using ultrasonography. A power analysis ensured sufficient enrolment.


Bone & Joint 360
Vol. 4, Issue 2 | Pages 32 - 34
1 Apr 2015

The April 2015 Research Roundup360 looks at: MCID in grip strength and distal radial fracture; Experiencing rehab in a trial setting; Electrical stimulation and nerve recovery; Molecular diagnosis of TB?; Acetabular orientation: component and arthritis; Analgesia after knee arthroplasty; Bisphosphonate-associated femoral fractures


Bone & Joint 360
Vol. 4, Issue 2 | Pages 15 - 17
1 Apr 2015

The April 2015 Foot & Ankle Roundup360 looks at: Plantar pressures linked to radiographs; Strength training for ankle instability?; Is weight loss good for your feet?; Diabetes and foot surgery complications; Tantalum for failed ankle arthroplasty?; Steroids, costs and Morton’s neuroma; Ankle arthritis and subtalar joint


Bone & Joint 360
Vol. 5, Issue 5 | Pages 22 - 25
1 Oct 2016


Bone & Joint Research
Vol. 5, Issue 1 | Pages 1 - 10
1 Jan 2016
Burghardt RD Manzotti A Bhave A Paley D Herzenberg JE

Objectives

The purpose of this study was to compare the results and complications of tibial lengthening over an intramedullary nail with treatment using the traditional Ilizarov method.

Methods

In this matched case study, 16 adult patients underwent 19 tibial lengthening over nails (LON) procedures. For the matched case group, 17 patients who underwent 19 Ilizarov tibial lengthenings were retrospectively matched to the LON group.


Bone & Joint 360
Vol. 5, Issue 4 | Pages 40 - 41
1 Aug 2016


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 722 - 725
1 Jun 2011
Buckley R Leighton R Trask K

The Canadian Orthopaedic Trauma Society was started in an endeavour to answer the difficult problem of obtaining enough patients to perform top-quality research into fractures. By maintaining a high standard, including randomised study design, inclusivity, open discussion among surgeons and excellent long-term follow-up, this group has become a leader in the orthopaedic research community. This annotation describes the short history, important components and spirit necessary to build a research community or team which will function well despite the difficult research environment facing individual surgeons.


The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 151 - 159
1 Feb 2013
Duckworth AD McQueen MM Ring D

Most fractures of the radial head are stable undisplaced or minimally displaced partial fractures without an associated fracture of the elbow or forearm or ligament injury, where stiffness following non-operative management is the primary concern. Displaced unstable fractures of the radial head are usually associated with other fractures or ligament injuries, and restoration of radiocapitellar contact by reconstruction or prosthetic replacement of the fractured head is necessary to prevent subluxation or dislocation of the elbow and forearm. In fractures with three or fewer fragments (two articular fragments and the neck) and little or no metaphyseal comminution, open reduction and internal fixation may give good results. However, fragmented unstable fractures of the radial head are prone to early failure of fixation and nonunion when fixed. Excision of the radial head is associated with good long-term results, but in patients with instability of the elbow or forearm, prosthetic replacement is preferred.

This review considers the characteristics of stable and unstable fractures of the radial head, as well as discussing the debatable aspects of management, in light of the current best evidence.

Cite this article: Bone Joint J 2013;95-B:151–9.


Bone & Joint 360
Vol. 5, Issue 4 | Pages 25 - 27
1 Aug 2016


Bone & Joint 360
Vol. 5, Issue 4 | Pages 23 - 25
1 Aug 2016


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 32 - 35
1 Nov 2014
Mirza AJ Lombardi Jr AV Morris MJ Berend KR

Direct anterior approaches to the hip have gained popularity as a minimally invasive method when performing primary total hip replacement (THR). A retrospective review of a single institution joint registry was performed in order to compare patient outcomes after THR using the Anterior Supine Intermuscular (ASI) approach versus a more conventional direct lateral approach. An electronic database identified 1511 patients treated with 1690 primary THRs between January 2006 and December 2010. Our results represent a summary of findings from our previously published work. We found that patients that underwent an ASI approach had faster functional recovery and higher Harris hip scores in the early post-operative period when compared with patients who had a direct lateral approach The overall complication rate in our ASI group was relatively low (1.7%) compared with other series using the same approach. The most frequent complication was early periprosthetic femoral fractures (0.9%). The dislocation rate in our series was 0.4% and the prosthetic joint infection rate was 0.1%. We suggest that the ASI approach is acceptable and safe when performing THR and encourages early functional recovery of our patients.

Cite this article: Bone Joint J 2014;96- B(11 Suppl A):32–5.


The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 881 - 886
1 Jul 2013
Bjorgul K Novicoff WN Andersen ST Ahlund OR Bunes A Wiig M Brevig K

A total of 397 hips were randomised to receive Metasul metal-on-metal (MoM), metal-on-conventional polyethylene (MoP) or ceramic-on-polyethylene (CoP) bearings using a cemented triple-tapered polished femoral component (MS-30). There were 129 MoM hips in 123 patients (39 male and 84 female, mean age 63.3 years (40.7 to 72.9)), 137 MoP hips in 127 patients (39 male and 88 female, mean age 62.8 years (24.5 to 72.7)) and 131 CoP hips in 124 patients (51 male and 73 female, mean age 63.9 years (30.6 to 73.8)). All acetabular components were cemented Weber polyethylene components with the appropriate inlay for the MoM articulation. Clinical evaluation was undertaken using the Harris hip score (HHS) and radiological assessments were made at two, five and seven years. The HHS and radiological analysis were available for 341 hips after seven years. The MoM group had the lowest mean HHS (p = 0.124), a higher rate of revision (p < 0.001) and a higher incidence of radiolucent lines in unrevised hips (p < 0.001). In all, 12 revisions had been performed in 12 patients: eight in the MoM group (four for infection, four for aseptic loosening, three in the MoP group (one each of infection, dislocation and pain) and one in the CoP group (infection).

Our findings reveal no advantage to the MoM bearing and identified a higher revision rate and a greater incidence of radiolucent lines than with the other articulations. We recommend that patients with a 28 mm Metasul MoM bearing be followed carefully.

Cite this article: Bone Joint J 2013;95-B:881–6.