Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1261 - 1267
14 Sep 2020
van Erp JHJ Gielis WP Arbabi V de Gast A Weinans H Arbabi S Öner FC Castelein RM Schlösser TPC

Aims. The aetiologies of common degenerative spine, hip, and knee pathologies are still not completely understood. Mechanical theories have suggested that those diseases are related to sagittal pelvic morphology and spinopelvic-femoral dynamics. The link between the most widely used parameter for sagittal pelvic morphology, pelvic incidence (PI), and the onset of degenerative lumbar, hip, and knee pathologies has not been studied in a large-scale setting. Methods. A total of 421 patients from the Cohort Hip and Cohort Knee (CHECK) database, a population-based observational cohort, with hip and knee complaints < 6 months, aged between 45 and 65 years old, and with lateral lumbar, hip, and knee radiographs available, were included. Sagittal spinopelvic parameters and pathologies (spondylolisthesis and degenerative disc disease (DDD)) were measured at eight-year follow-up and characteristics of hip and knee osteoarthritis (OA) at baseline and eight-year follow-up. Epidemiology of the degenerative disorders and clinical outcome scores (hip and knee pain and Western Ontario and McMaster Universities Osteoarthritis Index) were compared between low PI (< 50°), normal PI (50° to 60°), and high PI (> 60°) using generalized estimating equations. Results. Demographic details were not different between the different PI groups. L4 to L5 and L5 to S1 spondylolisthesis were more frequently present in subjects with high PI compared to low PI (L4 to L5, OR 3.717; p = 0.024 vs L5 to S1 OR 7.751; p = 0.001). L5 to S1 DDD occurred more in patients with low PI compared to high PI (OR 1.889; p = 0.010), whereas there were no differences in L4 to L5 DDD among individuals with a different PI. The incidence of hip OA was higher in participants with low PI compared to normal (OR 1.262; p = 0.414) or high PI (OR 1.337; p = 0.274), but not statistically different. The incidence of knee OA was higher in individuals with a high PI compared to low PI (OR 1.620; p = 0.034). Conclusion. High PI is a risk factor for development of spondylolisthesis and knee OA. Low pelvic incidence is related to DDD, and may be linked to OA of the hip. Level of Evidence: 1b. Cite this article: Bone Joint J 2020;102-B(9):1261–1267


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 5 | Pages 662 - 667
1 May 2008
Strauss EJ Egol KA Alaia M Hansen D Bashar M Steiger D

This study was undertaken to evaluate the safety and efficacy of retrievable inferior vena cava filters in high-risk orthopaedic patients. A total of 58 patients had a retrievable inferior vena cava filter placed as an adjunct to chemical and mechanical prophylaxis, most commonly for a history of previous deep-vein thrombosis or pulmonary embolism, polytrauma, or expected prolonged immobilisation. In total 56 patients (96.6%) had an uncomplicated post-operative course. Two patients (3.4%) died in the peri-operative period for unrelated reasons.

Of the 56 surviving patients, 50 (89%) were available for follow-up. A total of 32 filters (64%) were removed without complication at a mean of 37.8 days (4 to 238) after placement. There were four filters (8%) which were retained because of thrombosis at the filter site, and four (8%) were retained because of incorporation of the filter into the wall of the inferior vena cava. In ten cases (20%) the retrievable filter was left in place to continue as primary prophylaxis. No patient had post-removal thromboembolic complications.

A retrievable inferior vena cava filter, as an adjunct to chemical and mechanical prophylaxis, was a safe and effective means of reducing the acute risk of pulmonary embolism in this high-risk group of patients. Although most filters were removed without complications, thereby avoiding the long-term complications that have plagued permanent indwelling filters, a relatively high percentage of filters had to be left in situ.