Advertisement for orthosearch.org.uk
Results 1 - 5 of 5
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1158 - 1164
1 Oct 2024
Jakobi T Krieg I Gramlich Y Sauter M Schnetz M Hoffmann R Klug A

Aims. The aim of this study was to evaluate the outcome of complex radial head fractures at mid-term follow-up, and determine whether open reduction and internal fixation (ORIF) or radial head arthroplasty (RHA) should be recommended for surgical treatment. Methods. Patients who underwent surgery for complex radial head fractures (Mason type III, ≥ three fragments) were divided into two groups (ORIF and RHA) and propensity score matching was used to individually match patients based on patient characteristics. Ultimately, 84 patients were included in this study. After a mean follow-up of 4.1 years (2.0 to 9.5), patients were invited for clinical and radiological assessment. The Mayo Elbow Performance Score (MEPS), Oxford Elbow Score (OES), and Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire score were evaluated. Results. Patients treated with ORIF showed significantly better postoperative range of motion for flexion and extension (121.1° (SD 16.4°) vs 108.1° (SD 25.8°); p = 0.018). Postoperative functional scores also showed significantly better results in the ORIF group (MEPS 90.1 (SD 13.6) vs 78 (SD 20.5); p = 0.004). There was no significant difference between the groups in terms of the complication rate (RHA 23.8% (n = 10) vs ORIF 26.2% (n = 11)). Implant-related complications occurred in six cases (14.3%) in the RHA group and in five cases (11.9%) in the ORIF group. Conclusion. Irrespective of the patient’s age, sex, type of injury, or number of fracture fragments, ORIF of the radial head should be attempted initially, if a stable reconstruction can be achieved, as it seems to provide a superior postoperative outcome for the patient compared to primary RHA. If reconstruction is not feasible, RHA is still a viable alternative. In the surgical treatment of complex radial head fractures, reconstruction shows superior postoperative outcomes compared to RHA. Good postoperative results can be achieved even after failed reconstruction and conversion to secondary RHA. Therefore, we encourage surgeons to favour reconstruction of complex radial head fractures, regardless of injury type or number of fragments, as long as a stable fixation can be achieved. Cite this article: Bone Joint J 2024;106-B(10):1158–1164


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 482 - 491
1 May 2024
Davies A Sabharwal S Liddle AD Zamora Talaya MB Rangan A Reilly P

Aims. Metal and ceramic humeral head bearing surfaces are available choices in anatomical shoulder arthroplasties. Wear studies have shown superior performance of ceramic heads, however comparison of clinical outcomes according to bearing surface in total shoulder arthroplasty (TSA) and hemiarthroplasty (HA) is limited. This study aimed to compare the rates of revision and reoperation following metal and ceramic humeral head TSA and HA using data from the National Joint Registry (NJR), which collects data from England, Wales, Northern Ireland, Isle of Man and the States of Guernsey. Methods. NJR shoulder arthroplasty records were linked to Hospital Episode Statistics and the National Mortality Register. TSA and HA performed for osteoarthritis (OA) in patients with an intact rotator cuff were included. Metal and ceramic humeral head prostheses were matched within separate TSA and HA groups using propensity scores based on 12 and 11 characteristics, respectively. The primary outcome was time to first revision and the secondary outcome was non-revision reoperation. Results. A total of 4,799 TSAs (3,578 metal, 1,221 ceramic) and 1,363 HAs (1,020 metal, 343 ceramic) were included. The rate of revision was higher for metal compared with ceramic TSA, hazard ratio (HR) 3.31 (95% confidence interval (CI) 1.67 to 6.58). At eight years, prosthesis survival for ceramic TSA was 98.7% (95% CI 97.3 to 99.4) compared with 96.4% (95% CI 95.2 to 97.3) for metal TSA. The majority of revision TSAs were for cuff insufficiency or instability/dislocation. There was no significant difference in the revision rate for ceramic compared with metal head HA (HR 1.33 (95% CI 0.76 to 2.34)). For ceramic HA, eight-year prosthetic survival was 92.8% (95% CI 86.9 to 96.1), compared with 91.6% (95% CI 89.3 to 93.5) for metal HA. The majority of revision HAs were for cuff failure. Conclusion. The rate of all-cause revision was higher following metal compared with ceramic humeral head TSA in patients with OA and an intact rotator cuff. There was no difference in the revision rate for HA according to bearing surface. Cite this article: Bone Joint J 2024;106-B(5):482–491


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 268 - 276
1 Mar 2024
Park JH Lee JH Kim DY Kim HG Kim JS Lee SM Kim SC Yoo JC

Aims. This study aimed to assess the impact of using the metal-augmented glenoid baseplate (AGB) on improving clinical and radiological outcomes, as well as reducing complications, in patients with superior glenoid wear undergoing reverse shoulder arthroplasty (RSA). Methods. From January 2016 to June 2021, out of 235 patients who underwent primary RSA, 24 received a superior-AGB after off-axis reaming (Group A). Subsequently, we conducted propensity score matching in a 1:3 ratio, considering sex, age, follow-up duration, and glenoid wear (superior-inclination and retroversion), and selected 72 well-balanced matched patients who received a standard glenoid baseplate (STB) after eccentric reaming (Group B). Superior-inclination, retroversion, and lateral humeral offset (LHO) were measured to assess preoperative glenoid wear and postoperative correction, as well as to identify any complications. Clinical outcomes were measured at each outpatient visit before and after surgery. Results. There were no significant differences in demographic data and preoperative characteristics between the two groups. Both groups showed significant improvements in patient-reported outcome measures (visual analogue scale for pain, visual analogue scale for function, American Shoulder and Elbow Surgeons, Constant, and Simple Shoulder Test scores) from preoperative to final assessment (p < 0.001). However, AGB showed no additional benefit. Notably, within range of motion, Group B showed significant postoperative decrease in both external rotation and internal rotation, unlike Group A (p = 0.028 and 0.003, respectively). Both groups demonstrated a significant correction of superior-inclination after surgery, while patients in Group B exhibited a significant decrease in LHO postoperatively (p = 0.001). Regarding complications, Group A experienced more acromial stress fractures (3 cases; 12.5%), whereas Group B had a higher occurrence of scapular notching (24 cases; 33.3%) (p = 0.008). Conclusion. Both eccentric reaming with STB and off-axis reaming with AGB are effective methods for addressing superior glenoid wear in RSA, leading to improved clinical outcomes. However, it is important to be aware of the potential risks associated with eccentric reaming, which include excessive bone loss leading to reduced rotation and scapular notching. Cite this article: Bone Joint J 2024;106-B(3):268–276


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1303 - 1313
1 Dec 2023
Trammell AP Hao KA Hones KM Wright JO Wright TW Vasilopoulos T Schoch BS King JJ

Aims

Both anatomical and reverse total shoulder arthroplasty (aTSA and rTSA) provide functional improvements. A reported benefit of aTSA is better range of motion (ROM). However, it is not clear which procedure provides better outcomes in patients with limited foward elevation (FE). The aim of this study was to compare the outcome of aTSA and rTSA in patients with glenohumeral osteoarthritis (OA), an intact rotator cuff, and limited FE.

Methods

This was a retrospective review of a single institution’s prospectively collected shoulder arthroplasty database for TSAs undertaken between 2007 and 2020. A total of 344 aTSAs and 163 rTSAs, which were performed in patients with OA and an intact rotator cuff with a minimum follow-up of two years, were included. Using the definition of preoperative stiffness as passive FE ≤ 105°, three cohorts were matched 1:1 by age, sex, and follow-up: stiff aTSAs (85) to non-stiff aTSAs (85); stiff rTSAs (74) to non-stiff rTSAs (74); and stiff rTSAs (64) to stiff aTSAs (64). We the compared ROMs, outcome scores, and complication and revision rates.


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 666 - 673
1 May 2017
Werthel J Lonjon G Jo S Cofield R Sperling JW Elhassan BT

Aims. In the initial development of total shoulder arthroplasty (TSA), the humeral component was usually fixed with cement. Cementless components were subsequently introduced. The aim of this study was to compare the long-term outcome of cemented and cementless humeral components in arthroplasty of the shoulder. Patients and Methods. All patients who underwent primary arthroplasty of the shoulder at our institution between 1970 and 2012 were included in the study. There were 4636 patients with 1167 cemented humeral components and 3469 cementless components. Patients with the two types of fixation were matched for nine different covariates using a propensity score analysis. A total of 551 well-balanced pairs of patients with cemented and cementless components were available after matching for comparison of the outcomes. The clinical outcomes which were analysed included loosening of the humeral component determined at revision surgery, periprosthetic fractures, post-operative infection and operating time. Results. The overall five-, ten-, 15- and 20-year rates of survival were 98.9%, 97.2%, 95.5%, and 94.4%, respectively. Survival without loosening at 20 years was 98% for cemented components and 92.4% for cementless components. After propensity score matching including fixation as determined by the design of the component, humeral loosening was also found to be significantly higher in the cementless group. Survival without humeral loosening at 20 years was 98.7% for cemented components and 91.0% for cementless components. There was no significant difference in the risk of intra- or post-operative fracture. The rate of survival without deep infection and the mean operating time were significantly higher in the cemented group. Conclusion. Both types of fixation give rates of long-term survival of > 90%. Cemented components have better rates of survival without loosening but this should be weighed against increased operating time and the risk of bony destruction of the proximal humerus at the time of revision of a cemented humeral component. Cite this article: Bone Joint J 2017;99-B:666–73