Advertisement for orthosearch.org.uk
Results 1 - 6 of 6
Results per page:
The Bone & Joint Journal
Vol. 98-B, Issue 10 | Pages 1382 - 1388
1 Oct 2016
Laubscher M Mitchell C Timms A Goodier D Calder P

Aims

Patients undergoing femoral lengthening by external fixation tolerate treatment less well when compared to tibial lengthening. Lengthening of the femur with an intramedullary device may have advantages.

Patients and Methods

We reviewed all cases of simple femoral lengthening performed at our unit from 2009 to 2014. Cases of nonunions, concurrent deformities, congenital limb deficiencies and lengthening with an unstable hip were excluded, leaving 33 cases (in 22 patients; 11 patients had bilateral procedures) for review. Healing index, implant tolerance and complications were compared.


The Bone & Joint Journal
Vol. 95-B, Issue 9 | Pages 1227 - 1231
1 Sep 2013
Domeij-Arverud E Latifi A Labruto F Nilsson G Ackermann PW

We hypothesised that adjuvant intermittent pneumatic compression (IPC) beneath a plaster cast would reduce the risk of deep-vein thrombosis (DVT) during post-operative immobilisation of the lower limb. Of 87 patients with acute tendo Achillis (TA) rupture, 26 were prospectively randomised post-operatively after open TA repair. The treatment group (n = 14) received two weeks of IPC of the foot for at least six hours daily under a plaster cast. The control group (n = 12) had no additional treatment. At two weeks post-operatively all patients received an orthosis until follow-up at six weeks. At two and six weeks the incidence of DVT was assessed using colour duplex sonography by two ultrasonographers blinded to the treatment. Two patients withdrew from the study due to inability to tolerate IPC treatment. An interim analysis demonstrated a high incidence of DVT in both the IPC group (9 of 12, 75%) and the controls (6 of 12, 50%) (p = 0.18). No significant differences in incidence were detected at two (p = 0.33) or six weeks (p = 0.08) post-operatively. Malfunction of the IPC leading to a second plaster cast was found to correlate with an increased DVT risk at two weeks (φ = 0.71; p = 0.019), leading to a premature abandonment of the study. We cannot recommend adjuvant treatment with foot IPC under a plaster cast for outpatient DVT prevention during post-operative immobilisation, owing to a high incidence of DVT related to malfunctioning of this type of IPC application. Cite this article: Bone Joint J 2013;95-B:1227–31


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 788 - 792
1 Jun 2011
Schiedel FM Pip S Wacker S Pöpping J Tretow H Leidinger B Rödl R

We report the results of intramedullary leg lengthening conducted between 2002 and 2009 using the Intramedullary Skeletal Kinetic Distractor in 69 unilateral lengthenings involving 58 femora and 11 tibiae. We identified difficulties that occurred during the treatment and assessed whether they were specifically due to the implant or independent of it. Paley’s classification for evaluating problems, obstacles and complications with external fixators was adopted, and implant-specific difficulties were continuously noted. There were seven failures requiring premature removal of the device, in four due to nail breakage and three for other reasons, and five unsuccessful outcomes after completion of the lengthening. In all, 116 difficulties were noted in 45 patients, with only 24 having problem-free courses. In addition to the difficulties arising from the use of external fixators, there were almost the same number again of implant-specific difficulties. Nevertheless, successful femoral lengthening was achieved in 52 of the 58 patients (90%). However, successful tibial lengthening was only achieved in five of 11 patients (45%)


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 782 - 787
1 Jun 2011
Sun X Easwar TR Manesh S Ryu J Song S Kim S Song H

We compared the complications and outcome of tibial lengthening using the Ilizarov method with and without the use of a supplementary intramedullary nail. In a retrospective case-matched series assembled from 176 patients with tibial lengthening, we matched 52 patients (26 pairs, group A with nail and group B without) according to the following criteria in order of importance: 1) difference in amount of lengthening (± 2 cm); 2) percentage difference in lengthening (± 5%); 3) difference in patient’s age (± seven years); 4) aetiology of the shortening, and 5) level of difficulty in obtaining the correction. The outcome was evaluated using the external fixator index, the healing index and an outcome score according to the criteria of Paley. It was found that some complications were specific to group A or B respectively, but others were common to both groups.

The outcome was generally better in lengthenings with a nail, although there was a higher incidence of rectifiable equinus deformity in these patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 639 - 643
1 May 2011
Burghardt RD Herzenberg JE Specht SC Paley D

Between October 2001 and September 2009 we lengthened 242 lower-limb segments in 180 patients using the Intramedullary Skeletal Kinetic Distractor (ISKD). Mechanical failure was defined either as breakage of the ISKD or failure of the internal mechanism to activate. Retrieved nails which failed mechanically were examined by the manufacturer for defects. In all, 15 ISKDs in 12 patients (13 limbs) failed mechanically representing an overall failure rate of 6.2%, with fracture of the device occurring in ten of the 15 failures. Two nails in one patient failed to lengthen and had to be replaced. The manufacturer detected an error in the assembly of the nail, which prompted a wide recall. One nail jammed after being forcefully inserted, and two nails failed to lengthen fully. Lengthening was achieved in all 12 patients, although three required a second operation to exchange a defective nail for a new, functioning device.

The ISKD is a complex mechanical device which lengthens by the oscillation of two telescopic sections connected by a threaded rod. The junction between these sections is surrounded by a keyring collar. This keyring collar is the weakest part of the device.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 914 - 919
1 Jul 2006
Grondal L Broström E Wretenberg P Stark A

In a prospective randomised study 31 patients were allocated to either arthrodesis or Mayo resection of the first metatarsophalangeal joint as part of a total reconstruction of the rheumatoid forefoot. Of these, 29 were re-examined after a mean of 72 months (57 to 80), the Foot Function Index was scored and any deformity measured. Load distribution was analysed using a Fscan mat in 14 cases, and time and distance were measured in 12 of these patients using a 3D Motion system. We found excellent patient satisfaction and a significant, lasting reduction of the Foot Function Index, with no statistically significant differences between the groups. There were no significant differences in recurrence of the deformity, the need for special shoes, gait velocity, step length, plantar moment, mean pressure or the position of the centre of force under the forefoot. The cadence was higher and the stance phase shorter in the fusion group.

These results suggest that a Mayo resection may be an equally good option for managing the first metatarsophalangeal joint in reconstruction of the rheumatoid forefoot.