Advertisement for orthosearch.org.uk
Results 1 - 9 of 9
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1267 - 1273
1 Oct 2009
Queally JM Abdulkarim A Mulhall KJ

Neurological conditions affecting the hip pose a considerable challenge in replacement surgery since poor and imbalanced muscle tone predisposes to dislocation and loosening. Consequently, total hip replacement (THR) is rarely performed in such patients. In a systematic review of the literature concerning THR in neurological conditions, we found only 13 studies which described the outcome. We have reviewed the evidence and discussed the technical challenges of this procedure in patients with cerebral palsy, Parkinson’s disease, poliomyelitis and following a cerebrovascular accident, spinal injury or development of a Charcot joint. Contrary to traditional perceptions, THR can give a good outcome in these often severly disabled patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 7 | Pages 845 - 850
1 Jul 2009
Bannister G Amirfeyz R Kelley S Gargan M

This review discusses the causes, outcome and prevention of whiplash injury, which costs the economy of the United Kingdom approximately £3.64 billion per annum. Most cases occur as the result of rear-end vehicle collisions at speeds of less than 14 mph. Patients present with neck pain and stiffness, occipital headache, thoracolumbar back pain and upper-limb pain and paraesthesia. Over 66% make a full recovery and 2% are permanently disabled. The outcome can be predicted in 70% after three months.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 426 - 433
1 Apr 2009
Musahl V Tarkin I Kobbe P Tzioupis C Siska PA Pape H

The operative treatment of displaced fractures of the tibial plateau is challenging. Recent developments in the techniques of internal fixation, including the development of locked plating and minimal invasive techniques have changed the treatment of these fractures. We review current surgical approaches and techniques, improved devices for internal fixation and the clinical outcome after utilisation of new methods for locked plating.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 981 - 987
1 Aug 2008
Whittaker JP Dharmarajan R Toms AD

The management of bone loss in revision replacement of the knee remains a challenge despite an array of options available to the surgeon. Bone loss may occur as a result of the original disease, the design of the prosthesis, the mechanism of failure or technical error at initial surgery. The aim of revision surgery is to relieve pain and improve function while addressing the mechanism of failure in order to reconstruct a stable platform with transfer of load to the host bone. Methods of reconstruction include the use of cement, modular metal augmentation of prostheses, custom-made, tumour-type or hinged implants and bone grafting.

The published results of the surgical techniques are summarised and a guide for the management of bone defects in revision surgery of the knee is presented.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 5 | Pages 545 - 549
1 May 2008
Ashby E Grocott MPW Haddad FS

Orthopaedic outcome measures are used to evaluate the effect of operative interventions. They are used for audit and research. Knowledge of these measures is becoming increasingly important with league tables comparing surgeons and hospitals being made accessible to the profession and the general public.

Several types of tool are available to describe outcome after hip surgery such as generic quality-of-life questionnaires, disease-specific quality-of-life questionnaires, hip-specific outcome measures and general short-term clinical measures. We provide an overview of the outcome measures commonly used to evaluate hip interventions.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1413 - 1420
1 Nov 2007
FitzGerald J Fawcett J

The subject of central nervous system damage includes a wide variety of problems, from the slow selective ‘picking off’ of characteristic sub-populations of neurons typical of neurodegenerative diseases, to the wholesale destruction of areas of brain and spinal cord seen in traumatic injury and stroke. Experimental repair strategies are diverse and the type of pathology dictates which approach will be appropriate. Damage may be to grey matter (loss of neurons), white matter (cutting of axons, leaving neurons otherwise intact, at least initially) or both. This review will consider four possible forms of treatment for repair of the human central nervous system.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 8 | Pages 995 - 1000
1 Aug 2007
Siapkara A Duncan R

Talipes equinovarus is one of the more common congenital abnormalities affecting the lower limb and can be challenging to manage. This review provides a comprehensive update on idiopathic congenital talipes equinovarus with emphasis on the initial treatment. Current management is moving away from operative towards a more conservative treatment using the Ponseti regime. The long-term results of surgical correction and the recent results of conservative treatment will be discussed.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 12 | Pages 1549 - 1556
1 Dec 2006
McDermott ID Amis AA

The menisci of the knee have an important role in load-bearing and shock absorption within the joint. They may also function as secondary stabilisers, have a proprioceptive role, and aid the lubrication and nutrition of the articular cartilage. Complete or partial loss of a meniscus can have damaging effects on a knee, leading to serious long-term sequelae. This paper reviews the consequences of meniscectomy and summarises the body of evidence in the literature regarding those factors most relevant to long-term outcome


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1409 - 1418
1 Nov 2006
Scheerlinck T Casteleyn P

We undertook a review of the literature relating to the two basic stem designs in use in cemented hip replacement, namely loaded tapers or force-closed femoral stems, and the composite beam or shape-closed designs. The associated stem fixation theory as understood from in vitro studies and finite element modelling were examined with reference to the survivorship results for each of the concepts of fixation.

It is clear that both design principles are capable of producing successful long-term results, providing that their specific requirements of stem metallurgy, shape and surface finish, preparation of the bone and handling of the cement are observed.