The June 2023 Spine Roundup360 looks at: Characteristics and comparative study of thoracolumbar spine injury and dislocation fracture due to tertiary trauma; Sublingual sufentanil for postoperative pain management after lumbar spinal fusion surgery; Minimally invasive bipolar technique for adult neuromuscular scoliosis; Predictive factors for degenerative lumbar spinal stenosis; Lumbosacral transitional vertebrae and lumbar fusion surgery at level L4/5; Does recall of preoperative scores contaminate trial outcomes? A randomized controlled trial; Vancomycin in fibrin glue for prevention of SSI; Perioperative nutritional supplementation decreases wound healing complications following elective lumbar spine surgery: a randomized controlled trial.
It is uncertain whether instrumented spinal fixation in nonambulatory children with neuromuscular scoliosis should finish at L5 or be extended to the pelvis. Pelvic fixation has been shown to be associated with up to 30% complication rates, but is regarded by some as the standard for correction of deformity in these conditions. The incidence of failure when comparing the most caudal level of instrumentation, either L5 or the pelvis, using all-pedicle screw instrumentation has not previously been reported. In this retrospective study, we compared nonambulatory patients undergoing surgery at two centres: one that routinely instrumented to L5 and the other to the pelvis. In all, 91 nonambulatory patients with neuromuscular scoliosis were included. All underwent surgery using bilateral, segmental, pedicle screw instrumentation. A total of 40 patients underwent fusion to L5 and 51 had their fixation extended to the pelvis. The two groups were assessed for differences in terms of clinical and radiological findings, as well as complications.Aims
Methods
The anterior pelvic internal fixator is increasingly used for
the treatment of unstable, or displaced, injuries of the anterior
pelvic ring. The evidence for its use, however, is limited. The
aim of this paper is to describe the indications for its use, how
it is applied and its complications. We reviewed the case notes and radiographs of 50 patients treated
with an anterior pelvic internal fixator between April 2010 and
December 2015 at a major trauma centre in the United Kingdom. The
median follow-up time was 38 months (interquartile range 24 to 51).Aims
Patients and Methods
Aims. We compared the accuracy, operating time and radiation exposure
of the introduction of
The December 2015 Trauma Roundup360 looks at: Delay to surgery in hip fracture; Hexapod fixators in the management of hypertrophic tibial nonunions; Thromboembolism after nailing pathological fractures; Tibial plateau fracture patterns under the spotlight; The health economic effects of long bone nonunion; Adverse outcomes in trauma; The sacral screw in children; Treating the contralateral SUFE
We hypothesised that the anterior and posterior
walls of the body of the first sacral vertebra could be visualised with
two different angles of inlet view, owing to the conical shape of
the sacrum. Six dry male cadavers with complete pelvic rings and
eight dry sacrums with K-wires were used to study the effect of
canting (angling the C-arm) the fluoroscope towards the head in
5° increments from 10° to 55°. Fluoroscopic images were taken in
each position. Anterior and posterior angles of inclination were
measured between the upper sacrum and the vertical line on the lateral
view. Three authors separately selected the clearest image for overlapping
anterior cortices and the upper sacral canal in the cadaveric models.
The dry bone and K-wire models were scored by the authors, being
sure to check whether the
K-wire was in or out. In the dry bone models the mean score of the relevant inlet position
of the anterior or posterior inclination was 8.875 (standard deviation
(. sd. ) 0.35), compared with the inlet position of the opposite
inclination of –5.75 (. sd. 4.59). We found that two different
inlet views should be used separately to evaluate the borders of
the body of the sacrum using anterior and posterior inclination
angles of the sacrum, during placement of
Unstable pelvic injuries in young children with
an immature pelvis have different modes of failure from those in adolescents
and adults. We describe the pathoanatomy of unstable pelvic injuries
in these children, and the incidence of associated avulsion of the
iliac apophysis and fracture of the ipsilateral fifth lumbar transverse
process (L5-TP). We retrospectively reviewed the medical records
of 33 children with Tile types B and C pelvic injuries admitted
between 2007 and 2014; their mean age was 12.6 years (2 to 18) and
12 had an immature pelvis. Those with an immature pelvis commonly
sustained symphyseal injuries anteriorly with diastasis, rather
than the fractures of the pubic rami seen in adolescents. Posteriorly,
transsacral fractures were more commonly encountered in mature children,
whereas sacroiliac dislocations and fracture-dislocations were seen
in both age groups. Avulsion of the iliac apophysis was identified
in eight children, all of whom had an immature pelvis with an intact
ipsilateral L5-TP. Young children with an immature pelvis are more
susceptible to pubic symphysis and sacroiliac diastasis, whereas
bony failures are more common in adolescents. Unstable pelvic injuries
in young children are commonly associated with avulsion of the iliac
apophysis, particularly with displaced SI joint dislocation and
an intact ipsilateral L5-TP. Cite this article:
We performed a systematic review of the literature
to evaluate the use and interpretation of generic and disease-specific
functional outcome instruments in the reporting of outcome after
the surgical treatment of disruptions of the pelvic ring. A total
of 28 papers met our inclusion criteria, with eight reporting only
generic outcome instruments, 13 reporting only pelvis-specific outcome
instruments, and six reporting both. The Short-Form 36 (SF-36) was
by far the most commonly used generic outcome instrument, used in
12 papers, with widely variable reporting of scores. The pelvis-specific
outcome instruments were used in 19 studies; the Majeed score in
ten, Iowa pelvic score in six, Hannover pelvic score in two and
the Orlando pelvic score in one. Four sets of authors, all testing construct
validity based on correlation with the SF-36, performed psychometric
testing of three pelvis-specific instruments (Majeed, IPS and Orlando
scores). No testing of responsiveness, content validity, criterion
validity, internal consistency or reproducibility was performed. The existing literature in this area is inadequate to inform
surgeons or patients in a meaningful way about the functional outcomes
of these fractures after fixation.
The aim of this study was to assess the accuracy
of placement of pelvic binders and to determine whether circumferential
compression at the level of the greater trochanters is the best
method of reducing a symphyseal diastasis. Patients were identified by a retrospective review of all pelvic
radiographs performed at a military hospital over a period of 30
months. We analysed any pelvic radiograph on which the buckle of
the pelvic binder was clearly visible. The patients were divided
into groups according to the position of the buckle in relation
to the greater trochanters: high, trochanteric or low. Reduction
of the symphyseal diastasis was measured in a subgroup of patients
with an open-book fracture, which consisted of an injury to the
symphysis and disruption of the posterior pelvic arch (AO/OTA 61-B/C). We identified 172 radiographs with a visible pelvic binder. Five
cases were excluded due to inadequate radiographs. In 83 (50%) the
binder was positioned at the level of the greater trochanters. A
high position was the most common site of inaccurate placement,
occurring in 65 (39%). Seventeen patients were identified as a subgroup
to assess the effect of the position of the binder on reduction
of the diastasis. The mean gap was 2.8 times greater (mean difference
22 mm) in the high group compared with the trochanteric group (p
<
0.01). Application of a pelvic binder above the level of the greater
trochanters is common and is an inadequate method of reducing pelvic
fractures and is likely to delay cardiovascular recovery in these
seriously injured patients.
The purpose of this study was to assess the stability of a developmental pelvic reconstruction system which extends the concept of triangular osteosynthesis with fixation anterior to the lumbosacral pivot point. An unstable Tile type-C fracture, associated with a sacral transforaminal fracture, was created in synthetic pelves. The new concept was compared with three other constructs, including bilateral
We describe our early operative experience with a new pelvic reduction frame and the standard of reduction of fractures of the pelvic ring which we achieved in the first 35 consecutive patients, with 34 acute fractures and one nonunion. The pre-operative and immediate post-operative radiographs were measured, using two methods, to find the maximum radiological displacement of the fracture and the quality of the reduction according to the criteria of Tornetta and Matta. There were 19 vertical shear fractures and 16 compression injuries. The mean age of the patients was 33.5 years (10 to 59) and mean delay to surgery was 4.6 days (0 to 16) in the 34 acute injuries. The mean operative time in isolated procedures was 103.4 minutes (. sd. 6.5). All but one patient had
We reviewed 15 consecutive patients, 11 women and four men, with a mean age of 48.7 years (37.3 to 62.6), who between July 2004 and August 2007 had undergone percutaneous sacroiliac fusion using hollow modular anchorage screws filled with demineralised bone matrix. Each patient was carefully assessed to exclude other conditions and underwent pre-operative CT and MR scans. The diagnosis of symptomatic sacroiliac disease was confirmed by an injection of local anaesthetic and steroid under image intensifier control. The short form-36 questionnaire and Majeed’s scoring system were used for pre- and post-operative functional evaluation. Post-operative radiological evaluation was performed using plain radiographs. Intra-operative blood loss was minimal and there were no post-operative clinical or radiological complications. The mean follow-up was for 17 months (9 to 39). The mean short form-36 scores improved from 37 (23 to 51) to 80 (67 to 92) for physical function and from 53 (34 to 73) to 86 (70 to 98) for general health (p = 0.037). The mean Majeed’s score improved from 37 (18 to 54) pre-operatively to 79 (63 to 96) post-operatively (p = 0.014). There were 13 good to excellent results. The remaining two patients improved in short form-36 from a mean of 29 (26 to 35) to 48 (44 to 52). Their persistent pain was probably due to concurrent lumbar pathology. We conclude that percutaneous hollow modular anchorage screws are a satisfactory method of achieving sacroiliac fusion.
Crescent fracture dislocations are a well-recognised subset of pelvic ring injuries which result from a lateral compression force. They are characterised by disruption of the sacroiliac joint and extend proximally as a fracture of the posterior iliac wing. We describe a classification with three distinct types. Type I is characterised by a large crescent fragment and the dislocation comprises no more than one-third of the sacroiliac joint, which is typically inferior. Type II fractures are associated with an intermediate-size crescent fragment and the dislocation comprises between one- and two-thirds of the joint. Type III fractures are associated with a small crescent fragment where the dislocation comprises most, but not all of the joint. The principal goals of surgical intervention are the accurate and stable reduction of the sacroiliac joint. This classification proves useful in the selection of both the surgical approach and the reduction technique. A total of 16 patients were managed according to this classification and achieved good functional results approximately two years from the time of the index injury. Confounding factors compromise the summary short-form-36 and musculoskeletal functional assessment instrument scores, which is a well-recognised phenomenon when reporting the outcome of high-energy trauma.
With the development of systems of trauma care the management of pelvic disruption has evolved and has become increasingly refined. The goal is to achieve an anatomical reduction and stable fixation of the fracture. This requires adequate visualisation for reduction of the fracture and the placement of fixation. Despite the advances in surgical approach and technique, the functional outcomes do not always produce the desired result. New methods of percutaneous treatment in conjunction with innovative computer-based imaging have evolved in an attempt to overcome the existing difficulties. This paper presents an overview of the technical aspects of percutaneous surgery of the pelvis and acetabulum.
Various techniques have been used for the fixation of the posterior pelvis, each with disadvantages specific to the technique. In this study, a new protocol involving the placement of posterior pelvic screws in the CT suite is described and evaluated. A total of 66 patients with unstable pelvic ring injuries was stabilised under local anaesthesia with sedation. The mean length of time for the procedure was 26 minutes per screw. There were no technical difficulties or misplaced screws and no cases of infection or nonunion. All patients stated that they would choose to have the CT scan procedure again rather than a procedure requiring general anaesthesia. The charges for the procedure were approximately £1840 ($2800) per operation. CT-guided placement of