The aim of this study was to compare the early postoperative mortality and morbidity in older patients with a fracture of the femoral neck, between those who underwent total hip arthroplasty (THA) and those who underwent hemiarthroplasty. This nationwide, retrospective cohort study used data from the Japanese Diagnosis Procedure Combination database. We included older patients (aged ≥ 60 years) who underwent THA or hemiarthroplasty after a femoral neck fracture, between July 2010 and March 2022. A total of 165,123 patients were included. The THA group was younger (mean age 72.6 (SD 8.0) vs 80.7 years (SD 8.1)) and had fewer comorbidities than the hemiarthroplasty group. Patients with dementia or malignancy were excluded because they seldom undergo THA. The primary outcome measures were mortality and complications while in hospital, and secondary outcomes were readmission and reoperation within one and two years after discharge, and the costs of hospitalization. We conducted an instrumental variable analysis (IVA) using differential distance as a variable.Aims
Methods
This study aimed to compare mortality in trochanteric AO/OTA A1 and A2 fractures treated with an intramedullary nail (IMN) or sliding hip screw (SHS). The primary endpoint was 30-day mortality, with secondary endpoints at 0 to 1, 2 to 7, 8 to 30, 90, and 365 days. We analyzed data from 26,393 patients with trochanteric AO/OTA A1 and A2 fractures treated with IMNs (n = 9,095) or SHSs (n = 17,298) in the Norwegian Hip Fracture Register (January 2008 to December 2020). Exclusions were made for patients aged < 60 years, pathological fractures, pre-2008 operations, contralateral hip fractures, fractures other than trochanteric A1/A2, and treatments other than IMNs or SHSs. Kaplan-Meier and Cox regression analyses adjusted for type of fracture, age, sex, cognitive impairment, American Society of Anesthesiologists (ASA) grade, and time period were conducted, along with calculations for number needed to harm (NNH).Aims
Methods
The aim of the present study was to assess the outcomes of the induced membrane technique (IMT) for the management of infected segmental bone defects, and to analyze predictive factors associated with unfavourable outcomes. Between May 2012 and December 2020, 203 patients with infected segmental bone defects treated with the IMT were enrolled. The digital medical records of these patients were retrospectively analyzed. Factors associated with unfavourable outcomes were identified through logistic regression analysis.Aims
Methods
The aim of this study was to report the three-year follow-up for a series of 400 patients with a displaced intracapsular fracture of the hip, who were randomized to be treated with either a cemented polished tapered hemiarthroplasty or an uncemented hydroxyapatite-coated hemiarthroplasty. The mean age of the patients was 85 years (58 to 102) and 273 (68%) were female. Follow-up was undertaken by a nurse who was blinded to the hemiarthroplasty that was used, at intervals for up to three years from surgery. The short-term follow-up of these patients at a mean of one year has previously been reported.Aims
Methods
The aim of this study was to assess the association of mortality and reoperation when comparing cemented and uncemented hemiarthroplasty (HA) in hip fracture patients aged over 65 years. This was a population-based cohort study on hip fracture patients using prospectively gathered data from several national registries in Denmark from 2004 to 2015 with up to five years follow-up. The primary outcome was mortality and the secondary outcome was reoperation. Hazard ratios (HRs) for mortality and subdistributional hazard ratios (sHRs) for reoperations are shown with 95% confidence intervals (CIs).Aims
Methods
Deep surgical site infection (SSI) remains an unsolved problem after hip fracture. Debridement, antibiotic, and implant retention (DAIR) has become a mainstream treatment in elective periprosthetic joint infection; however, evidence for DAIR after infected hip hemiarthroplaty is limited. Patients who underwent a hemiarthroplasty between March 2007 and August 2018 were reviewed. Multivariable binary logistic regression was performed to identify and adjust for risk factors for SSI, and to identify factors predicting a successful DAIR at one year.Aims
Methods
To clarify the effectiveness of the induced membrane technique (IMT) using beta-tricalcium phosphate (β-TCP) for reconstruction of segmental bone defects by evaluating clinical and radiological outcomes, and the effect of defect size and operated site on surgical outcomes. A review of the medical records was conducted of consecutive 35 lower limbs (30 males and five females; median age 46 years (interquartile range (IQR) 40 to 61)) treated with IMT using β-TCP between 2014 and 2018. Lower Extremity Functional Score (LEFS) was examined preoperatively and at final follow-up to clarify patient-centered outcomes. Bone healing was assessed radiologically, and time from the second stage to bone healing was also evaluated. Patients were divided into ≥ 50 mm and < 50 mm defect groups and into femoral reconstruction, tibial reconstruction, and ankle arthrodesis groups.Aims
Methods
Aims. Patients receiving cemented hemiarthroplasties after hip fracture have a significant risk of deep surgical site infection (SSI). Standard UK practice to minimize the risk of SSI includes the use of antibiotic-loaded
The aim of this study was to describe variation in hip fracture treatment in Norway expressed as adherence to international and national evidence-based treatment guidelines, to study factors influencing deviation from guidelines, and to analyze consequences of non-adherence. International and national guidelines were identified and treatment recommendations extracted. All 43 hospitals routinely treating hip fractures in Norway were characterized. From the Norwegian Hip Fracture Register (NHFR), hip fracture patients aged > 65 years and operated in the period January 2014 to December 2018 for fractures with conclusive treatment guidelines were included (n = 29,613: femoral neck fractures (n = 21,325), stable trochanteric fractures (n = 5,546), inter- and subtrochanteric fractures (n = 2,742)). Adherence to treatment recommendations and a composite indicator of best practice were analyzed. Patient survival and reoperations were evaluated for each recommendation.Aims
Methods
Debate continues about whether it is better to use a cemented or uncemented hemiarthroplasty to treat a displaced intracapsular fracture of the hip. The aim of this study was to attempt to resolve this issue for contemporary prostheses. A total of 400 patients with a displaced intracapsular fracture of the hip were randomized to receive either a cemented polished tapered stem hemiarthroplasty or an uncemented Furlong hydroxyapatite-coated hemiarthroplasty. Follow-up was conducted by a nurse blinded to the implant at set intervals for up to one year from surgery.Aims
Methods
The aim of this study was to investigate mortality and risk of intraoperative medical complications depending on delay to hip fracture surgery by using data from the Norwegian Hip Fracture Register (NHFR) and the Norwegian Patient Registry (NPR). A total of 83 727 hip fractures were reported to the NHFR between 2008 and 2017. Pathological fractures, unspecified type of fractures or treatment, patients less than 50 years of age, unknown delay to surgery, and delays to surgery of greater than four days were excluded. We studied total delay (fracture to surgery, n = 38 754) and hospital delay (admission to surgery, n = 73 557). Cox regression analyses were performed to calculate relative risks (RRs) adjusted for sex, age, American Society of Anesthesiologists (ASA) classification, type of surgery, and type of fracture. Odds ratio (OR) was calculated for intraoperative medical complications. We compared delays of 12 hours or less, 13 to 24 hours, 25 to 36 hours, 37 to 48 hours, and more than 48 hours.Aims
Patients and Methods
This study describes and compares the operative management and outcomes in a consecutive case series of patients with dislocated hemiarthroplasties of the hip, and compares outcomes with those of patients not sustaining a dislocation. Of 3326 consecutive patients treated with hemiarthroplasty for fractured neck of femur, 46 (1.4%) sustained dislocations. Of the 46 dislocations, there were 37 female patients (80.4%) and nine male patients (19.6%) with a mean age of 83.8 years (66 to 100). Operative intervention for each, and subsequent dislocations, were recorded. The following outcome measures were recorded: dislocation; mortality up to one-year post-injury; additional surgery; residential status; mobility; and pain score at one year.Aims
Patients and Methods
Aims. A fracture of the hip is the most common serious orthopaedic
injury, and surgical site infection (SSI) is one of the most significant
complications, resulting in increased mortality, prolonged hospital
stay and often the need for further surgery. Our aim was to determine
whether high dose dual antibiotic impregnated
We report the outcome of 84 nonunions involving
long bones which were treated with rhBMP-7, in 84 patients (60 men:
24 women) with a mean age 46 years (18 to 81) between 2003 and 2011.
The patients had undergone a mean of three previous operations (one
to 11) for nonunion which had been present for a mean of 17 months
(4 months to 20 years). The nonunions involved the lower limb in
71 patients and the remainder involved the upper limb. A total of 30
nonunions were septic. Treatment was considered successful when
the nonunion healed without additional procedures. The relationship
between successful union and the time to union was investigated
and various factors including age and gender, the nature of the
nonunion (location, size, type, chronicity, previous procedures,
infection, the condition of the soft tissues) and type of index
procedure (revision of fixation, type of graft, amount of rhBMP-7) were
analysed. The improvement of the patients’ quality of life was estimated
using the Short Form (SF) 12 score. A total of 68 nonunions (80.9%) healed with no need for further
procedures at a mean of 5.4 months (3 to 10) post-operatively. Multivariate
logistic regression analysis of the factors affecting union suggested
that only infection significantly affected the rate of union
(p = 0.004).Time to union was only affected by the number of previous
failed procedures
(p = 0.006). An improvement of 79% and 32.2% in SF-12 physical and
mental score, respectively, was noted within the first post-operative
year. Rh-BMP-7 combined with bone grafts, enabled healing of the nonunion
and improved quality of life in about 80% of patients. Aseptic nonunions
were much more likely to unite than septic ones. The number of previous
failed operations significantly delayed the time to union. Cite this article:
The aims of this study were to identify the early
in-hospital mortality rate after hip fracture, identify factors associated
with this mortality, and identify the cause of death in these patients.
A retrospective cohort study was performed on 4426 patients admitted
to our institution between the 1 January 2006 and 31 December 2013
with a hip fracture (1128 male (26%), mean age 82.0 years (60 to
105)). Admissions increased annually, but despite this 30-day mortality
decreased from 12.1% to 6.5%; 77% of these were in-hospital deaths.
Male gender (odds ratio (OR) 2.0, 95% confidence interval (CI) 1.3
to 3.0), increasing age (age ≥ 91; OR 4.1, 95% CI 1.4 to 12.2) and
comorbidity (American Society of Anesthesiologists grades 3 to 5;
OR 4.2, 95% CI 2.0 to 8.7) were independently and significantly
associated with increased odds of in-hospital mortality. From 220
post-mortem reports, the most common causes of death were respiratory
infections (35%), ischaemic heart disease (21%), and cardiac failure
(13%). A sub-group of hip fracture patients at highest risk of early
death can be identified with these risk factors, and the knowledge
of the causes of death can be used to inform service improvements
and the development of a more didactic care pathway, so that multidisciplinary
intervention can be focused for this sub-group in order to improve
their outcome. Cite this article:
It is becoming increasingly common for a patient
to have ipsilateral hip and knee replacements. The inter-prosthetic (IP)
distance, the distance between the tips of hip and knee prostheses,
has been thought to be associated with an increased risk of IP fracture.
Small gap distances are generally assumed to act as stress risers,
although there is no real biomechanical evidence to support this. The purpose of this study was to evaluate the influence of IP
distance, cortical thickness and bone mineral density on the likelihood
of an IP femoral fracture. A total of 18 human femur specimens were randomised into three
groups by bone density and cortical thickness. For each group, a
defined IP distance of 35 mm, 80 mm or 160 mm was created by choosing
the appropriate lengths of component. The maximum fracture strength
was determined using a four-point bending test. The fracture force of all three groups was similar (p = 0.498).
There was a highly significant correlation between the cortical
area and the fracture strength (r = 0.804, p <
0.001), whereas
bone density showed no influence. This study suggests that the IP distance has little influence
on fracture strength in IP femoral fractures: the thickness of the
cortex seems to be the decisive factor. Cite this article:
The augmentation of fixation with bone cement
is increasingly being used in the treatment of severe osteoporotic fractures.
We investigated the influence of bone quality on the mechanics of
augmentation of plate fixation in a distal femoral fracture model
(AO 33 A3 type). Eight osteoporotic and eight non-osteoporotic femoral
models were randomly assigned to either an augmented or a non-augmented
group. Fixation was performed using a locking compression plate.
In the augmented group additionally 1 ml of
Using data from the Norwegian Hip Fracture Register,
8639 cemented and 2477 uncemented primary hemiarthroplasties for
displaced fractures of the femoral neck in patients aged > 70 years
were included in a prospective observational study. A total of 218
re-operations were performed after cemented and 128 after uncemented
procedures. Survival of the hemiarthroplasties was calculated using
the Kaplan-Meier method and hazard rate ratios (HRR) for revision
were calculated using Cox regression analyses. At five years the
implant survival was 97% (95% confidence interval (CI) 97 to 97)
for cemented and 91% (95% CI 87 to 94) for uncemented hemiarthroplasties.
Uncemented hemiarthroplasties had a 2.1 times increased risk of
revision compared with cemented prostheses (95% confidence interval
1.7 to 2.6, p < 0.001). The increased risk was mainly caused
by revisions for peri-prosthetic fracture (HRR = 17), aseptic loosening
(HRR = 17), haematoma formation (HRR = 5.3), superficial infection
(HRR = 4.6) and dislocation (HRR = 1.8). More intra-operative complications,
including intra-operative death, were reported for the cemented
hemiarthroplasties. However, in a time-dependent analysis, the HRR
for re-operation in both groups increased as follow-up increased. This study showed that the risk for revision was higher for uncemented
than for cemented hemiarthroplasties.
We undertook a prospective randomised controlled trial involving 400 patients with a displaced intracapsular fracture of the hip to determine whether there was any difference in outcome between treatment with a cemented Thompson hemiarthroplasty and an uncemented Austin-Moore prosthesis. The surviving patients were followed up for between two and five years by a nurse blinded to the type of prosthesis used. The mean age of the patients was 83 years (61 to 104) and 308 (77%) were women. The degree of residual pain was less in those treated with a cemented prosthesis (p <
0.0001) three months after surgery. Regaining mobility was better in those treated with a cemented implant (p = 0.005) at six months after operation. No statistically significant difference was found between the two groups with regard to mortality, implant-related complications, re-operations or post-operative medical complications. The use of a cemented Thompson hemiarthroplasty resulted in less pain and less deterioration in mobility than an uncemented Austin-Moore prosthesis with no increase in complications.
We used an inverted shoulder arthroplasty in 43 consecutive patients with a mean age of 78 years (65 to 97) who had sustained a three- or four-part fracture of the upper humerus. All except two were reviewed with a mean follow-up of 22 months (6 to 58). The clinical outcome was satisfactory with a mean active anterior elevation of 97° (35° to 160°) and a mean active external rotation in abduction of 30° (0° to 80°). The mean Constant and the mean modified Constant scores were respectively 44 (16 to 69) and 66% (25% to 97%). Complications included three patients with reflex sympathetic dystrophy, five with neurological complications, most of which resolved, and one with an anterior dislocation. Radiography showed peri-prosthetic calcification in 36 patients (90%), displacement of the tuberosities in 19 (53%) and a scapular notch in ten (25%). Compared with conventional hemiarthroplasty, satisfactory mobility was obtained despite frequent migration of the tuberosities. However, long-term results are required before reverse shoulder arthroplasty can be recommended as a routine procedure in complex fractures of the upper humerus in the elderly.