Advertisement for orthosearch.org.uk
Results 1 - 12 of 12
Results per page:
Bone & Joint Open
Vol. 5, Issue 10 | Pages 818 - 824
2 Oct 2024
Moroder P Herbst E Pawelke J Lappen S Schulz E

Aims

The liner design is a key determinant of the constraint of a reverse total shoulder arthroplasty (rTSA). The aim of this study was to compare the degree of constraint of rTSA liners between different implant systems.

Methods

An implant company’s independent 3D shoulder arthroplasty planning software (mediCAD 3D shoulder v. 7.0, module v. 2.1.84.173.43) was used to determine the jump height of standard and constrained liners of different sizes (radius of curvature) of all available companies. The obtained parameters were used to calculate the stability ratio (degree of constraint) and angle of coverage (degree of glenosphere coverage by liner) of the different systems. Measurements were independently performed by two raters, and intraclass correlation coefficients were calculated to perform a reliability analysis. Additionally, measurements were compared with parameters provided by the companies themselves, when available, to ensure validity of the software-derived measurements.


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 958 - 963
3 May 2021
Nguyen NTV Martinez-Catalan N Songy CE Sanchez-Sotelo J

Aims

The purpose of this study was to report bone adaptive changes after anatomical total shoulder arthroplasty (TSA) using a standard-length hydroxyapatite (HA)-coated humeral component, and to report on a computer-based analysis of radiographs to determine changes in peri-implant bone density objectively.

Methods

A total of 44 TSAs, performed between 2011 and 2014 using a cementless standard-length humeral component proximally coated with HA, were included. There were 23 males and 21 females with a mean age of 65 years (17 to 65). All shoulders had good quality radiographs at six weeks and five years postoperatively. Three observers graded bone adaptive changes. All radiographs were uploaded into a commercially available photographic software program. The grey value density of humeral radiological areas was corrected to the grey value density of the humeral component and compared over time.


Bone & Joint Open
Vol. 1, Issue 12 | Pages 731 - 736
1 Dec 2020
Packer TW Sabharwal S Griffiths D Reilly P

Aims

The purpose of this study was to evaluate the cost of reverse shoulder arthroplasty (RSA) for patients with a proximal humerus fracture, using time-driven activity based costing (TDABC), and to compare treatment costs with reimbursement under the Healthcare Resource Groups (HRGs).

Methods

TDABC analysis based on the principles outlined by Kaplan and a clinical pathway that has previously been validated for this institution was used. Staffing cost, consumables, implants, and overheads were updated to reflect 2019/2020 costs. This was compared with the HRG reimbursements.


The Bone & Joint Journal
Vol. 101-B, Issue 6 | Pages 702 - 707
1 Jun 2019
Moeini S Rasmussen JV Salomonsson B Domeij-Arverud E Fenstad AM Hole R Jensen SL Brorson S

Aims

The aim of this study was to use national registry database information to estimate cumulative rates and relative risk of revision due to infection after reverse shoulder arthroplasty.

Patients and Methods

We included 17 730 primary shoulder arthroplasties recorded between 2004 and 2013 in The Nordic Arthroplasty Register Association (NARA) data set. With the Kaplan–Meier method, we illustrated the ten-year cumulative rates of revision due to infection and with the Cox regression model, we reported the hazard ratios as a measure of the relative risk of revision due to infection.


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1609 - 1617
1 Dec 2018
Malhas AM Granville-Chapman J Robinson PM Brookes-Fazakerley S Walton M Monga P Bale S Trail I

Aims

We present our experience of using a metal-backed prosthesis and autologous bone graft to treat gross glenoid bone deficiency.

Patients and Methods

A prospective cohort study of the first 45 shoulder arthroplasties using the SMR Axioma Trabecular Titanium (TT) metal-backed glenoid with autologous bone graft. Between May 2013 and December 2014, 45 shoulder arthroplasties were carried out in 44 patients with a mean age of 64 years (35 to 89). The indications were 23 complex primary arthroplasties, 12 to revise a hemiarthroplasty or resurfacing, five for aseptic loosening of the glenoid, and five for infection.


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1493 - 1498
1 Nov 2018
Wagner ER Hevesi M Houdek MT Cofield RH Sperling JW Sanchez-Sotelo J

Aims

Patients with a failed reverse shoulder arthroplasty (RSA) have limited salvage options. The aim of this study was to determine the outcome of revision RSA when used as a salvage procedure for a failed primary RSA.

Patients and Methods

We reviewed all revision RSAs performed for a failed primary RSA between 2006 and 2012, excluding patients with a follow-up of less than two years. A total of 27 revision RSAs were included in the study. The mean age of the patients at the time of revision was 70 years (58 to 82). Of the 27 patients, 14 (52% were female). The mean follow-up was 4.4 years (2 to 10).


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1074 - 1079
1 Aug 2018
Paul R Knowles N Chaoui J Gauci M Ferreira L Walch G Athwal GS

Aims

The Walch Type C dysplastic glenoid is characterized by excessive retroversion. This anatomical study describes its morphology.

Patients and Methods

A total of 29 shoulders with a dysplastic glenoid were analyzed. CT was used to measure retroversion, inclination, height, width, radius-of-curvature, surface area, depth, subluxation of the humeral head and the Goutallier classification of fatty infiltration. The severity of dysplasia and deficiency of the posterior rim of the glenoid were recorded.


The Bone & Joint Journal
Vol. 100-B, Issue 3 | Pages 318 - 323
1 Mar 2018
Raiss P Alami G Bruckner T Magosch P Habermeyer P Boileau P Walch G

Aims

The aim of this study was to analyze the results of reverse shoulder arthroplasty (RSA) in patients with type 1 sequelae of a fracture of the proximal humerus in association with rotator cuff deficiency or severe stiffness of the shoulder.

Patients and Methods

A total of 38 patients were included: 28 women and ten men. Their mean age at the time of arthroplasty was 73 years (54 to 91). Before the RSA, 18 patients had been treated with open reduction and internal fixation following a fracture. A total of 22 patients had a rotator cuff tear and 11 had severe stiffness of the shoulder with < 0° of external rotation. The mean follow-up was 4.3 years (1.5 to 10). The Constant score and the range of movement of the shoulder were recorded preoperatively and at final follow-up.

Preoperatively, radiographs in two planes were performed, as well as CT or arthro-CT scans; radiographs were also performed at final follow-up.


The Bone & Joint Journal
Vol. 98-B, Issue 7 | Pages 969 - 975
1 Jul 2016
Theivendran K Varghese M Large R Bateman M Morgan M Tambe A Espag M Cresswell T Clark DI

Aim. We present the medium-term clinical results of a reverse total shoulder arthroplasty with a trabecular metal glenoid base plate. Patients and Methods. We reviewed 125 consecutive primary reverse total shoulder arthroplasties (RTSA) implanted in 124 patients for rotator cuff arthropathy. There were 100 women and 24 men in the study group with a mean age of 76 years (58 to 89). The mean follow-up was 32 months (24 to 60). No patient was lost to follow-up. Results. There were statistically significant improvements in the mean range of movement and Oxford Shoulder Score (p < 0.001). Kaplan-Meier survivorship at five years was 96.7% (95% confidence interval 91.5 to 98.7) with aseptic glenoid failure as the end point. . Radiologically, 63 shoulders (50.4%) showed no evidence of notching, 51 (40.8%) had grade 1 notching, ten (8.0%) had grade 2 notching and one (0.8%) had grade 4 notching. Radiolucency around the glenoid base plate was found in one patient (0.8%) and around the humeral stem in five (4.0%). In all, three RTSA (2.4%) underwent revision surgery for aseptic mechanical failure of the glenoid within 11 months of surgery due to malseating of the glenosphere. Conclusion. The clinical results of this large independent single unit series are comparable to those from previous series of RTSA reported in the literature. A trabecular metal base plate is safe and effective in the medium-term. Cite this article: Bone Joint J 2016;98-B:969–75


The Bone & Joint Journal
Vol. 98-B, Issue 2 | Pages 218 - 223
1 Feb 2016
Scalise J Jaczynski A Jacofsky M

Aims

The eccentric glenosphere was principally introduced into reverse shoulder arthroplasty to reduce the incidence of scapular notching. There is only limited information about the influence of its design on deltoid power and joint reaction forces.

The aim of our study was to investigate how the diameter and eccentricity of the glenosphere affect the biomechanics of the deltoid and the resultant joint reaction forces.

Methods

Different sizes of glenosphere and eccentricity were serially tested in ten cadaveric shoulders using a custom shoulder movement simulator.


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1239 - 1243
1 Sep 2014
Zafra M Uceda P Flores M Carpintero P

Patients with pain and loss of shoulder function due to nonunion of a fracture of the proximal third of the humerus may benefit from reverse total shoulder replacement. This paper reports a prospective, multicentre study, involving three hospitals and three surgeons, of 35 patients (28 women, seven men) with a mean age of 69 years (46 to 83) who underwent a reverse total shoulder replacement for the treatment of nonunion of a fracture of the proximal humerus. Using Checchia’s classification, nine nonunions were type I, eight as type II, 12 as type III and six as type IV. The mean follow-up was 51 months (24 to 99). Post-operatively, the patients had a significant decrease in pain (p < 0.001), and a significant improvement in flexion, abduction, external rotation and Constant score (p < 0.001), but not in internal rotation. A total of nine complications were recorded in seven patients: six dislocations, one glenoid loosening in a patient who had previously suffered dislocation, one transitory paresis of the axillary nerve and one infection.

Reverse total shoulder replacement may lead to a significant reduction in pain, improvement in function and a high degree of satisfaction. However, the rate of complications, particularly dislocation, was high.

Cite this article: Bone Joint J 2014;96-B:1239–43.


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 224 - 228
1 Feb 2014
Simone JP Streubel PH Athwal GS Sperling JW Schleck CD Cofield RH

We assessed the clinical results, radiographic outcomes and complications of patients undergoing total shoulder replacement (TSR) for osteoarthritis with concurrent repair of a full-thickness rotator cuff tear. Between 1996 and 2010, 45 of 932 patients (4.8%) undergoing TSR for osteoarthritis underwent rotator cuff repair. The final study group comprised 33 patients with a mean follow-up of 4.7 years (3 months to 13 years). Tears were classified into small (10), medium (14), large (9) or massive (0). On a scale of 1 to 5, pain decreased from a mean of 4.7 to 1.7 (p = < 0.0001), the mean forward elevation improved from 99° to 139° (p = < 0.0001), and the mean external rotation improved from 20° (0° to 75°) to 49° (20° to 80°) (p = < 0.0001). The improvement in elevation was greater in those with a small tear (p = 0.03). Radiographic evidence of instability developed in six patients with medium or large tears, indicating lack of rotator cuff healing. In all, six glenoid components, including one with instability, were radiologically at risk of loosening. Complications were noted in five patients, all with medium or large tears; four of these had symptomatic instability and one sustained a late peri-prosthetic fracture. Four patients (12%) required further surgery, three with instability and one with a peri-prosthetic humeral fracture.

Consideration should be given to performing rotator cuff repair for stable shoulders during anatomical TSR, but reverse replacement should be considered for older, less active patients with larger tears.

Cite this article: Bone Joint J 2014;96-B:224–8.