Advertisement for orthosearch.org.uk
Results 1 - 20 of 23
Results per page:
Bone & Joint Research
Vol. 13, Issue 10 | Pages 588 - 595
17 Oct 2024
Breu R Avelar C Bertalan Z Grillari J Redl H Ljuhar R Quadlbauer S Hausner T

Aims

The aim of this study was to create artificial intelligence (AI) software with the purpose of providing a second opinion to physicians to support distal radius fracture (DRF) detection, and to compare the accuracy of fracture detection of physicians with and without software support.

Methods

The dataset consisted of 26,121 anonymized anterior-posterior (AP) and lateral standard view radiographs of the wrist, with and without DRF. The convolutional neural network (CNN) model was trained to detect the presence of a DRF by comparing the radiographs containing a fracture to the inconspicuous ones. A total of 11 physicians (six surgeons in training and five hand surgeons) assessed 200 pairs of randomly selected digital radiographs of the wrist (AP and lateral) for the presence of a DRF. The same images were first evaluated without, and then with, the support of the CNN model, and the diagnostic accuracy of the two methods was compared.


Bone & Joint Research
Vol. 10, Issue 2 | Pages 113 - 121
1 Feb 2021
Nicholson JA Oliver WM MacGillivray TJ Robinson CM Simpson AHRW

Aims

To evaluate if union of clavicle fractures can be predicted at six weeks post-injury by the presence of bridging callus on ultrasound.

Methods

Adult patients managed nonoperatively with a displaced mid-shaft clavicle were recruited prospectively. Ultrasound evaluation of the fracture was undertaken to determine if sonographic bridging callus was present. Clinical risk factors at six weeks were used to stratify patients at high risk of nonunion with a combination of Quick Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH) ≥ 40, fracture movement on examination, or absence of callus on radiograph.


The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 935 - 941
1 Jul 2013
Moor BK Bouaicha S Rothenfluh DA Sukthankar A Gerber C

We hypothesised that a large acromial cover with an upwardly tilted glenoid fossa would be associated with degenerative rotator cuff tears (RCTs), and conversely, that a short acromion with an inferiorly inclined glenoid would be associated with glenohumeral osteoarthritis (OA). This hypothesis was tested using a new radiological parameter, the critical shoulder angle (CSA), which combines the measurements of inclination of the glenoid and the lateral extension of the acromion (the acromion index).

The CSA was measured on standardised radiographs of three groups: 1) a control group of 94 asymptomatic shoulders with normal rotator cuffs and no OA; 2) a group of 102 shoulders with MRI-documented full-thickness RCTs without OA; and 3) a group of 102 shoulders with primary OA and no RCTs noted during total shoulder replacement. The mean CSA was 33.1° (26.8° to 38.6°) in the control group, 38.0° (29.5° to 43.5°) in the RCT group and 28.1° (18.6° to 35.8°) in the OA group. Of patients with a CSA > 35°, 84% were in the RCT group and of those with a CSA < 30°, 93% were in the OA group.

We therefore concluded that primary glenohumeral OA is associated with significantly smaller degenerative RCTs with significantly larger CSAs than asymptomatic shoulders without these pathologies. These findings suggest that individual quantitative anatomy may imply biomechanics that are likely to induce specific types of degenerative joint disorders.

Cite this article: Bone Joint J 2013;95-B:935–41.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1534 - 1539
1 Nov 2012
Karataglis D Papadopoulos P Boutsiadis A Fotiadou A Ditsios K Hatzokos I Christodoulou A

This study evaluates the position of the long head of biceps tendon using ultrasound following simple tenotomy, in patients with arthroscopically repaired rotator cuff tears.

In total, 52 patients with a mean age of 60.7 years (45 to 75) underwent arthroscopic repair of the rotator cuff and simple tenotomy of the long head of biceps tendon. At two years post-operatively, ultrasound revealed that the tendon was inside the bicipital groove in 43 patients (82.7%) and outside in nine (17.3%); in six of these it was lying just outside the groove and in the remaining three (5.8%) it was in a remote position with a positive Popeye Sign. A dynamic ultrasound scan revealed that the tenotomised tendons had adhered to the surrounding tissues (autotenodesis).The initial condition of the tendon influenced its final position (p < 0.0005). The presence of a Popeye sign was statistically influenced by the pre-operative co-existence of supraspinatus and subscapularis tears (p < 0.0001).

It appears that the natural history of the tenotomised long head of biceps tendon is to tenodese itself inside or just outside the bicipital groove, while its pre-operative condition and coexistent subscapularis tears play a significant role in the occurrence of a Popeye sign.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1247 - 1252
1 Sep 2011
Sinha A Edwin J Sreeharsha B Bhalaik V Brownson P

This study investigated the anatomical relationship between the clavicle and its adjacent vascular structures, in order to define safe zones, in terms of distance and direction, for drilling of the clavicle during osteosynthesis using a plate and screws following a fracture. We used reconstructed three-dimensional CT arteriograms of the head, neck and shoulder region. The results have enabled us to divide the clavicle into three zones based on the proximity and relationship of the vascular structures adjacent to it. The results show that at the medial end of the clavicle the subclavian vessels are situated behind it, with the vein intimately related to it. In some scans the vein was opposed to the posterior cortex of the clavicle. At the middle one-third of the clavicle the artery and vein are a mean of 17.02 mm (5.4 to 26.8) and 12.45 mm (5 to 26.1) from the clavicle, respectively, and at a mean angle of 50° (12 to 80) and 70° (38 to 100), respectively, to the horizontal. At the lateral end of the clavicle the artery and vein are at mean distances of 63.4 mm (46.8 to 96.5) and 75.67 mm (50 to 109), respectively.

An appreciation of the information gathered from this study will help minimise the risk of inadvertent iatrogenic vascular injury during plating of the clavicle.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 7 | Pages 932 - 936
1 Jul 2011
Mahmoud M Koptan W

Ununited fractures of the scaphoid with extensive bone resorption are usually treated by bone grafting and internal fixation, using either an open or a minimally invasive technique. We studied the feasibility of percutaneous fixation without bone grafting in a consecutive series of 27 patients with established nonunion of an undisplaced fracture of the scaphoid and extensive local resorption of bone. They were treated by a single surgeon with rigid fixation alone, using a headless cannulated screw inserted through a volar percutaneous technique. Clinical examination, standard radiographs and CT confirmed that the fracture had united in all patients at a mean of 11.6 weeks (8 to 16), and that their functional scores had improved.

We concluded that extensive resorption at the fracture site is not an absolute indication for bone grafting, and that percutaneous fixation alone will eventually produce healing of ununited undisplaced fractures of the scaphoid regardless of the size of the gap.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 713 - 719
1 Jun 2011
Duckworth AD Ring D McQueen MM

A suspected fracture of the scaphoid remains difficult to manage despite advances in knowledge and imaging methods. Immobilisation and restriction of activities in a young and active patient must be balanced against the risks of nonunion associated with an undiagnosed and undertreated fracture of the scaphoid.

The assessment of diagnostic tests for a suspected fracture of the scaphoid must take into account two important factors. First, the prevalence of true fractures among suspected fractures is low, which greatly reduces the probability that a positive test will correspond with a true fracture, as false positives are nearly as common as true positives. This situation is accounted for by Bayesian statistics. Secondly, there is no agreed reference standard for a true fracture, which necessitates the need for an alternative method of calculating diagnostic performance characteristics, based upon a statistical method which identifies clinical factors tending to associate (latent classes) in patients with a high probability of fracture.

The most successful diagnostic test to date is MRI, but in low-prevalence situations the positive predictive value of MRI is only 88%, and new data have documented the potential for false positive scans. The best strategy for improving the diagnosis of true fractures among suspected fractures of the scaphoid may well be to develop a clinical prediction rule incorporating a set of demographic and clinical factors which together increase the pre-test probability of a fracture of the scaphoid, in addition to developing increasingly sophisticated radiological tests.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1397 - 1402
1 Oct 2010
Nada AN Debnath UK Robinson DA Jordan C

We describe the clinical outcome of a technique of surgical augmentation of chronic massive tears of the rotator cuff using a polyester ligament (Dacron) in 21 symptomatic patients (14 men, seven women) with a mean age of 66.5 years (55.0 to 85.0). All patients had MRI and arthroscopic evidence of chronic massive tears. The clinical outcome was assessed using the Constant and Murley and patient satisfaction scores at a mean follow-up of 36 months (30 to 46).

The polyester ligament (500 mm × 10 mm) was passed into the joint via the portal of Neviaser, medial to the tear through healthy cuff. The two ends of the ligament holding the cuff were passed through tunnels made in the proximal humerus at the footprint of the insertion of the cuff. The ligament was tied with a triple knot over the humeral cortex.

All the patients remained free from pain (p < 0.001) with improvement in function (p < 0.001) and range of movement (p < 0.001). The mean pre-operative and post-operative Constant scores were 46.7 (39.0 to 61.0) and 85.4 (52.0 to 96.0), respectively (p < 0.001). The mean patient satisfaction score was 90%. There were two failures, one due to a ruptured ligament after one year and the other due to deep-seated infection. The MR scan at the final follow-up confirmed intact and thickened bands in 15 of 17 patients.

This technique of augmentation gives consistent relief from pain with improved shoulder movement in patients with symptomatic massive tears of the rotator cuff.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1410 - 1415
1 Oct 2010
Castagna A Randelli M Garofalo R Maradei L Giardella A Borroni M

Total shoulder replacement is a successful procedure for degenerative or some inflammatory diseases of the shoulder. However, fixation of the glenoid seems to be the main weakness with a high rate of loosening. The results using all-polyethylene components have been better than those using metal-backed components. We describe our experience with 35 consecutive total shoulder replacements using a new metal-backed glenoid component with a mean follow-up of 75.4 months (48 to 154).

Our implant differs from others because of its mechanism of fixation. It has a convex metal-backed bone interface and the main stabilising factor is a large hollow central peg. The patients were evaulated with standard radiographs and with the Constant Score, the Simple Shoulder Test and a visual analogue scale. All the scores improved and there was no loosening, no polyethylene-glenoid disassembly and no other implant-related complications.

We conclude that a metal-backed glenoid component is a good option in total shoulder replacement with no worse results than of those using a cemented all-polyethylene prosthesis.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 83 - 91
1 Jan 2010
Moosmayer S Lund G Seljom U Svege I Hennig T Tariq R Smith H

In order to compare the outcome from surgical repair and physiotherapy, 103 patients with symptomatic small and medium-sized tears of the rotator cuff were randomly allocated to one of the two approaches. The primary outcome measure was the Constant score, and secondary outcome measures included the self-report section of the American Shoulder and Elbow Surgeons score, the Short Form 36 Health Survey and subscores for shoulder movement, pain, strength and patient satisfaction. Scores were taken at baseline and after six and 12 months by a blinded assessor. Nine patients (18%) with insufficient benefit from physiotherapy after at least 15 treatment sessions underwent secondary surgical treatment.

Analysis of between-group differences showed better results for the surgery group on the Constant scale (difference 13.0 points, p − 0.002), on the American Shoulder and Elbow surgeons scale (difference 16.1 points, p < 0.0005), for pain-free abduction (difference 28.8°, p = 0.003) and for reduction in pain (difference on a visual analogue scale −1.7 cm, p < 0.0005).


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 12 | Pages 1587 - 1593
1 Dec 2009
Oh JH Kim SH Kim JH Shin YH Yoon JP Oh CH

This study examined the role of vitamin D as a factor accounting for fatty degeneration and muscle function in the rotator cuff. There were 366 patients with disorders of the shoulder. A total of 228 patients had a full-thickness tear (group 1) and 138 patients had no tear (group 2). All underwent magnetic resonance arthrography and an isokinetic muscle performance test. The serum concentrations of vitamin D (25(OH)D3) were measured.

In general, a lower serum level of vitamin D was related to higher fatty degeneration in the muscles of the cuff. Spearman’s correlation coefficients were 0.173 (p = 0.001), −0.181 (p = 0.001), and −0.117 (p = 0.026) for supraspinatus, infraspinatus and subscapularis, respectively. In group 1, multivariate linear regression analysis revealed that the serum level of vitamin D was an independent variable for fatty degeneration of the supraspinatus and infraspinatus.

The serum vitamin D level has a significant negative correlation with the fatty degeneration of the cuff muscle and a positive correlation with isokinetic muscle torque.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 6 | Pages 762 - 765
1 Jun 2009
Toros T Karabay N Özaksar K Sugun TS Kayalar M Bal E

We prospectively studied 26 consecutive patients with clinically documented sensory or motor deficiency of a peripheral nerve due to trauma or entrapment using ultrasound, and in 19 cases surgical exploration of the nerves was undertaken. The ultrasonographic diagnoses were correlated with neurological examination and the surgical findings. Reliable visualisation of injured nerves on ultrasonography was achieved in all patients. Axonal swelling and hypoechogenity of the nerve was diagnosed in 15 cases, loss of continuity of a nerve bundle in 17, the formation of a neuroma of a stump in six, and partial laceration of a nerve with loss of the normal fascicular pattern in five. The ultrasonographic findings were confirmed at operation in those who had surgery.

Ultrasound may be used for the evaluation of peripheral nerve injuries in the upper limb. High-resolution ultrasound can show the exact location, extent and type of lesion, yielding important information that might not be obtainable by other diagnostic aids.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 2 | Pages 196 - 200
1 Feb 2009
Moosmayer S Smith H Tariq R Larmo A

We undertook clinical and ultrasonographic examination of the shoulders of 420 asymptomatic volunteers aged between 50 and 79 years. MRI was performed in selected cases. Full-thickness tears of the rotator cuff were detected in 32 subjects (7.6%). The prevalence increased with age as follows: 50 to 59 years, 2.1%; 60 to 69 years, 5.7%; and 70 to 79 years, 15%. The mean size of the tear was less than 3 cm and tear localisation was limited to the supraspinatus tendon in most cases (78%). The strength of flexion was reduced significantly in the group with tears (p = 0.01).

Asymptomatic tears of the rotator cuff should be regarded as part of the normal ageing process in the elderly but may be less common than hitherto believed.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 12 | Pages 1597 - 1601
1 Dec 2008
Thompson NW Kapoor A Thomas J Hayton MJ

We describe the use of a vascularised periosteal patch onlay graft based on the 1,2 intercompartmental supraretinacular artery in the management of 11 patients (ten men, one woman) with chronic nonunion involving the proximal third of the scaphoid. The mean age of the patients was 31 years (21 to 45) with the dominant hand affected in eight. Six of the patients were smokers and three had undergone previous surgery to the scaphoid. All of the proximal fragments were avascular. The presence of union was assessed using longitudinal axis CT.

Only three patients progressed to union of the scaphoid and four required a salvage operation for a symptomatic nonunion. The remaining four patients with a persistent nonunion are asymptomatic with low pain scores, good grip strength and a functional range of wrist movement.

Although this technique has potential technical advantages over vascularised pedicled bone grafting, the rate of union has been disappointing and we do not recommend it as a method of treatment.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 9 | Pages 1205 - 1209
1 Sep 2008
Beeres FJP Rhemrev SJ den Hollander P Kingma LM Meylaerts SAG le Cessie S Bartlema KA Hamming JF Hogervorst M

We evaluated 100 consecutive patients with a suspected scaphoid fracture but without evidence of a fracture on plain radiographs using MRI within 24 hours of injury, and bone scintigraphy three to five days after injury. The reference standard for a true radiologically-occult scaphoid fracture was either a diagnosis of fracture on both MRI and bone scintigraphy, or, in the case of discrepancy, clinical and/or radiological evidence of a fracture.

MRI revealed 16 scaphoid and 24 other fractures. Bone scintigraphy showed 28 scaphoid and 40 other fractures. According to the reference standard there were 20 scaphoid fractures. MRI was falsely negative for scaphoid fracture in four patients and bone scintigraphy falsely positive in eight. MRI had a sensitivity of 80% and a specificity of 100%. Bone scintigraphy had a sensitivity of 100% and a specificity of 90%.

This study did not confirm that early, short-sequence MRI was superior to bone scintigraphy for the diagnosis of a suspected scaphoid fracture. Bone scintigraphy remains a highly sensitive and reasonably specific investigation for the diagnosis of an occult scaphoid fracture.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 889 - 892
1 Jul 2008
Al-Shawi A Badge R Bunker T

We have examined the accuracy of 143 consecutive ultrasound scans of patients who subsequently underwent shoulder arthroscopy for rotator-cuff disease. All the scans and subsequent surgery were performed by an orthopaedic surgeon using a portable ultrasound scanner in a one-stop clinic. There were 78 full thickness tears which we confirmed by surgery or MRI. Three moderate-size tears were assessed as partial-thickness at ultrasound scan (false negative) giving a sensitivity of 96.2%. One partially torn and two intact cuffs were over-diagnosed as small full-thickness tears by ultrasound scan (false positive) giving a specificity of 95.4%. This gave a positive predictive value of 96.2% and a negative predictive value of 95.4%. Estimation of tear size was more accurate for large and massive tears at 96.5% than for moderate (88.8%) and small tears (91.6%). These results are equivalent to those obtained by several studies undertaken by experienced radiologists. We conclude that ultrasound imaging of the shoulder performed by a sufficiently-trained orthopaedic surgeon is a reliable time-saving practice to identify rotator-cuff integrity


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 3 | Pages 336 - 342
1 Mar 2008
Cuff DJ Virani NA Levy J Frankle MA Derasari A Hines B Pupello DR Cancio M Mighell M

We retrospectively reviewed 21 patients (22 shoulders) who presented with deep infection after surgery to the shoulder, 17 having previously undergone hemiarthroplasty and five open repair of the rotator cuff. Nine shoulders had undergone previous surgical attempts to eradicate their infection. The diagnosis of infection was based on a combination of clinical suspicion (16 shoulders), positive frozen sections (> 5 polymorphonuclear leukocytes per high-power field) at the time of revision (15 shoulders), positive intra-operative cultures (18 shoulders) or the pre-operative radiological appearances. The patients were treated by an extensive debridement, intravenous antibiotics, and conversion to a reverse shoulder prosthesis in either a single- (10 shoulders) or a two-stage (12 shoulders) procedure.

At a mean follow-up of 43 months (25 to 66) there was no evidence of recurrent infection. All outcome measures showed statistically significant improvements. Mean abduction improved from 36.1° (sd 27.8) pre-operatively to 75.7° (sd 36.0) (p < 0.0001), the mean forward flexion from 43.1° (sd 33.5) to 79.5° (sd 43.2) (p = 0.0003), and mean external rotation from 10.2° (sd 18.7) to 25.4° (sd 23.5) (p = 0.0037). There was no statistically significant difference in any outcome between the single-stage and the two-stage group.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 1 | Pages 61 - 65
1 Jan 2008
O’Donnell TMP McKenna JV Kenny P Keogh P O’Flanagan SJ

Antegrade intramedullary nailing of fractures of the shaft of the humerus is reported to cause impairment of the shoulder joint. We have reviewed 33 patients with such fractures to assess how many had injuries to the ipsilateral shoulder. All had an MR scan of the shoulder within 11 days of injury. The unaffected shoulder was also scanned as a control. There was evidence of abnormality in 21 of the shoulders (63.6%) on the injured side; ten had bursitis of the subacromial space, five evidence of a partial tear of the rotator cuff, one a complete rupture of the supraspinatus tendon, four inflammatory changes in the acromioclavicular joint and one a fracture of the coracoid process. These injuries may contribute to pain and dysfunction of the shoulder following treatment, and their presence indicates that antegrade nailing is only partly, if at all, responsible for these symptoms.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1197 - 1200
1 Sep 2007
Quraishi NA Johnston P Bayer J Crowe M Chakrabarti AJ

This study prospectively evaluated the outcome of manipulation under anaesthesia and hydrodilatation as treatments for adhesive capsulitis. A total of 36 patients (38 shoulders) were randomised to receive either method, with all patients being treated in stage II of the disease process.

The mean age of the patients was 55.2 years (44 to 70) and the mean duration of symptoms was 33.7 weeks (12 to 76). Eighteen shoulders (17 patients) underwent manipulation under anaesthesia and 20 (19 patients) had hydrodilatation. There were three insulin-dependent diabetics in each group. The mean visual analogue score in the manipulation under anaesthesia group was 5.7 (3 to 8.5; n = 18) before treatment, 4.7 (0 to 8.5; n = 16) at two months (paired t-test p = 0.02), and 2.7 (0 to 9; n = 16) at six months (paired t-test, p = 0.0006). The mean score in the hydrodilatation group was 6.1 (4 to 10; n = 20) before treatment, 2.4 (0 to 8; n = 18) at two months (paired t-test, p = 0.001), and 1.7 (0 to 7; n = 18) at six months (paired t-test, p = 0.0006). The visual analogue scores in the hydrodilatation group were significantly better than in the manipulation under anaesthesia group over the six-month follow-up period (p < 0.0001).

The mean Constant score in those manipulated was 36 (26 to 66) before treatment, 58.5 (24 to 90) at two months (paired t-test, p = 0.001) and 59.5 (23 to 85) at six months (paired t-test, p = 0.0006). In the hydrodilatation group it was 28.8 (18 to 55) before treatment, 57.4 (17 to 80) at two months (paired t-test, p = 0.0004) and 65.9 (28 to 92) at six months (paired t-test, p = 0.0005). The Constant scores in the hydrodilatation group were significantly better than in the manipulated group over the six-month period of follow-up (p = 0.02).

The range of movement improved in all patients over the six months, but was not significantly different between the groups. At the final follow-up, 94% of patients (17 of 18) were satisfied or very satisfied after hydrodilatation compared with 81% (13 of 16) of those receiving a manipulation.

Most of our patients were treated successfully, but those undergoing hydrodilatation did better than those who were manipulated.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 3 | Pages 335 - 341
1 Mar 2007
Albert J Meadeb J Guggenbuhl P Marin F Benkalfate T Thomazeau H Chalès G

In a prospective randomised trial of calcifying tendinitis of the rotator cuff, we compared the efficacy of dual treatment sessions delivering 2500 extracorporeal shock waves at either high- or low-energy, via an electromagnetic generator under fluoroscopic guidance. Patients were eligible for the study if they had more than a three-month history of calcifying tendinitis of the rotator cuff, with calcification measuring 10 mm or more in maximum dimension. The primary outcome measure was the change in the Constant and Murley Score.

A total of 80 patients were enrolled (40 in each group), and were re-evaluated at a mean of 110 (41 to 255) days after treatment when the increase in Constant and Murley score was significantly greater (t-test, p = 0.026) in the high-energy treatment group than in the low-energy group. The improvement from the baseline level was significant in the high-energy group, with a mean gain of 12.5 (−20.7 to 47.5) points (p < 0.0001). The improvement was not significant in the low-energy group. Total or subtotal resorption of the calcification occurred in six patients (15%) in the high-energy group and in two patients (5%) in the low-energy group.

High-energy shock-wave therapy significantly improves symptoms in refractory calcifying tendinitis of the shoulder after three months of follow-up, but the calcific deposit remains unchanged in size in the majority of patients.