The conversion of previous hip fracture surgery to total hip arthroplasty (CTHA) can be surgically challenging with unpredictable outcomes; reported complication rates vary significantly. This study aimed to establish the medium-term survival and outcomes of CTHA performed following a previous hip fracture surgery. All CTHAs performed at our tertiary orthopaedic institution between January 2008 and January 2020 following previous ipsilateral hip fracture surgery were included. Patients were followed up clinically using Oxford Hip Scores (OHS), and radiologically until death or revision surgery. Postoperative complications, radiological implant failure, and indications for revision surgery were reviewed.Aims
Methods
Aims. Revision hip arthroplasty for femoral stem loosening remains challenging due to significant bone loss and deformities requiring specialized revision stems. The aim of this study was to evaluate the clinical and radiological outcomes, and survival, of a consecutive series of femoral revisions performed using a primary cementless stem with tapered geometry and rectangular cross-section at medium-term follow-up. Methods. We retrospectively evaluated 113 patients (115 hips) with intraoperative Paprosky type I (n = 86) or II (n = 29) defects, who underwent femoral revision with Alloclassic Zweymüller SL stem for one-stage aseptic revision or two-stage septic revision from January 2011 to December 2020. The mean follow-up was 77.9 months (SD 33.8). Nine patients were lost to follow-up (deceased or not available), leaving 104 patients (106 hips) for the clinical and radiological analysis. Clinical assessment was performed with Harris Hip Score (HHS) and visual analogue scale (VAS) before surgery and at final follow-up. Results. There were 60 males and 53 females with a mean age at time of surgery of 71.2 years (SD 12.6). The mean HHS and VAS significantly improved at final follow-up, from 33.7 (SD 13.0) and 5.8 (SD 1.8) preoperatively to 66.4 (SD 16.8) and 2.1 (SD 1.8) postoperatively, respectively (p = 0.001 and p = 0.001). Overall, 28 patients (25%) showed non-progressive radiolucent lines at the level of proximal femur without radiological or clinical signs of loosening. One patient had a recurrence of
The February 2025 Hip & Pelvis Roundup360 looks at: Postoperative periprosthetic femoral fractures after hip arthroplasty: quantifying the other half of the picture; Hip arthroscopy in patients with borderline dysplasia: how do we know when it will not work?; The morbidly obese patient remains a challenge for arthroplasty surgeons; Unexpected positive cultures in aseptic revision hip and knee arthroplasty: does it make a difference?; Failed spinal anaesthesia in hip and knee arthroplasty surgery; Clinical failure of femoral neck fracture is associated with varus necks; Navigating the angles: how variations in femoral and acetabular versions influence hip pain and treatment; High-tech or hands-on? Similar outcomes in direct anterior total hip arthroplasty.
The February 2025 Knee Roundup360 looks at: Once-weekly semaglutide in patients with obesity and knee osteoarthritis; How many patients should have a unicompartmental knee arthroplasty?; Staged revision of the infected knee arthroplasty and endoprosthesis; The metal allergy argument and knee arthroplasty; Is kinematic alignment all it’s cracked up to be?; Is bone-patella-bone the gold standard for revision?; Blood flow restriction and the dissatisfied knee arthroplasty.
The February 2025 Trauma Roundup360 looks at: Risk factors for nonunion in femoral neck fracture patients with internal fixation: a multicentre (TRON group) retrospective study; Tranexamic acid administered at time of hospital admission does not decrease transfusion rates or blood loss for extracapsular hip fractures; The effect of anterior support screw (AS2) in unstable femoral trochanteric fractures; The effect of coronal plane angulation on patient-reported outcome measures of operatively treated distal femur fractures; Do proximal humerus fractures treated nonoperatively benefit from supervised physiotherapy?; Cephalomedullary nails: are dual lag screws superior to single lag screws?; Does cement need to be pressurized for hemiarthroplasty?.
The aim of this study was to assess the incidence of reinfection in patients after two-stage revision of an infected megaprosthesis (MPR) implanted after resection of a bone tumour. A retrospective study was carried out of 186 patients from 16 bone sarcoma centres treated between January 2010 and December 2020. The median age at the time of tumour diagnosis was 26 years (IQR 17 to 33); 69 (37.1%) patients were female, and 117 (62.9%) were male.Aims
Methods
Aims. To evaluate the concurrent use of vancomycin and ε-aminocaproic acid (EACA) in primary total hip arthroplasty (THA). Methods. In total, 120 patients undergoing unilateral primary THA were divided into three groups: Group VE received intra-articular vancomycin and EACA; Group V received only intra-articular vancomycin; and Group E received only intra-articular EACA. Blood and joint fluids were sampled postoperatively to measure the vancomycin levels using chromatography. Blood loss and kidney function were monitored. Results. Groups E and VE had equivalent blood loss, which was less than that in Group V. Intra-articular vancomycin levels were higher in Group VE at all intervals, with similar serum levels across the groups. Acute kidney injury, ototoxicity, and allergies were not observed, nor was a difference in rates of
Aims. Older adults with hip fractures are at high risk of experiencing complications after surgery, but estimates of the rate of specific complications vary by study design and follow-up period. The aim of this systematic review was to determine the prevalence of complications in older adults after hip fracture surgery. Methods. MEDLINE, Embase, CINAHL, and CENTRAL databases were searched from inception until 30 June 2023. Studies were included if they reported prevalence data of complications in an unselected, consecutive population of older adults (aged ≥ 60 years) undergoing hip fracture surgery. Results. A total of 95 studies representing 2,521,300 patients were included. For surgery-specific complications, the 30-day prevalence of reoperation was 2.31%, surgical site infection 1.69%, and deep surgical site infection 0.98%; the 365-day prevalence of prosthesis dislocation was 1.11%, fixation failure 1.77%, and
The aim of this study was to assess the necessity of revising the acetabular component in revision total hip arthroplasty (THA) in patients with a Vancouver type B2 periprosthetic femoral fracture (PFF) who require revision of the femoral component. The hypothesis was that revision of both the acetabular and femoral components and using a dual-mobility acetabular component would provide a lower postoperative risk of dislocation, without increasing perioperative morbidity and mortality. Data were retrospectively analyzed from a continuously gathered database. We included 150 revisions, performed between January 2015 and December 2022, in 150 patients, with 81 revisions limited to only the femoral component and 69 involving revision of both components. This resulted, after surgery, in 60 patients having a simple-mobility acetabular component and 90 having a dual-mobility component. The mean age of the patients was 79.7 years (SD 10.1), and 98 were female (65.3%). The mean follow-up was 31 months (SD 2.3).Aims
Methods
The February 2025 Shoulder & Elbow Roundup360 looks at: Reverse shoulder arthroplasty is superior to plate fixation for displaced proximal humeral fractures in the elderly; Long-term outcomes of reverse total shoulder arthroplasty for complex proximal humerus fractures; The RAND/UCLA algorithm does streamline the clinical decision-making process; Smoking negatively impacts long-term outcomes and survival after anatomical total shoulder arthroplasty; Evaluating subscapularis tears: special tests lack sensitivity to tear severity and pain; Rotator cuff tear progression: insights into rates, risk factors, and the need for standardized reporting; Outcomes and complications of revision reverse shoulder arthroplasty: a systematic review; Prevalence and risk factors of glenohumeral chondral damage in shoulder instability: implications for early surgical stabilization.
Aims. While cementless fixation offers potential advantages over cemented fixation, such as a shorter operating time, concerns linger over its higher cost and increased risk of
The aim of this study was to report long-term clinical outcomes of a modern convertible metal-backed glenoid (MBG) in total shoulder arthroplasty (TSA). After a minimum of 15 years, a previously studied cohort of 35 patients who received a modern convertible MBG during the period 1996 to 2005 was contacted for clinical and radiological follow-up. At last follow-up, patients were evaluated radiologically and clinically according to the Constant Score, Simple Shoulder Test, and visual analogue scale for pain. Complications and revisions were recorded, and survival analysis was performed.Aims
Methods
We estimated the prevalence of people living with at least one hip, knee, or shoulder arthroplasty in the Netherlands. We included the first hip (n = 416,333), knee (n = 314,569), or shoulder (n = 23,751) arthroplasty of each patient aged ≥ 40 years between 2007 and 2022 (hip/knee) or 2014 and 2022 (shoulder) from the Dutch Arthroplasty Register (LROI). Data on the size of the Dutch population were obtained from Statistics Netherlands. Annual incidences and deaths from hip and knee arthroplasty since 2010, and shoulder arthroplasty since 2015, were observed from the LROI. Annual incidences and deaths before those years were estimated using Poisson regression analyses and parametric survival models based on a Gompertz distribution. Non-parametric percentile bootstrapping with resampling was used to estimate 95% CIs.Aims
Methods
Aims. The Peri-Implant and
Around the world, the emergence of robotic technology has improved surgical precision and accuracy in total knee arthroplasty (TKA). This territory-wide study compares the results of various robotic TKA (R-TKA) systems with those of conventional TKA (C-TKA) and computer-navigated TKA (N-TKA). This is a retrospective study utilizing territory-wide data from the Clinical Data Analysis and Reporting System (CDARS). All patients who underwent primary TKA in all 47 public hospitals in Hong Kong between January 2021 and December 2023 were analyzed. Primary outcomes were the percentage use of various robotic and navigation platforms. Secondary outcomes were: 1) mean length of stay (LOS); 2) 30-day emergency department (ED) attendance rate; 3) 90-day ED attendance rate; 4) 90-day reoperation rate; 5) 90-day mortality rate; and 6) surgical time.Aims
Methods
The purpose of this study was to directly compare the Modular Dual Mobility (MDM) Mobile Bearing Hip System (Stryker, USA) and large femoral heads (LFHs) in revision total hip arthroplasties (THAs) at mid-term follow-up, with specific emphasis on survival free of re-revision for dislocation, any re-revision, dislocation, and the risk of metal-related complications. We identified 299 revision THAs performed at a single tertiary care academic institution from March 2011 to July 2014. Aseptic loosening of the acetabular component (n = 65), dislocation (n = 58), and reimplantation as part of a two-stage exchange protocol (n = 57) were the most common reasons for index revision. MDM constructs were used in 123 cases, and LFHs were used in 176 cases. Mean age was 66 years (28 to 93), mean BMI was 31 kg/m2 (18 to 55), and 45% (n = 136) were female. Mean follow-up was seven years (2 to 12).Aims
Methods
Tibial fixation in revision total knee arthroplasty (rTKA) can present surgical challenges. It has been suggested that appropriate fixation in at least two of the three anatomical zones (epiphysis, metaphysis, and diaphysis) is essential for implant survival. However, supporting clinical data are lacking. In this retrospective case-control study, we investigated the relationship between zonal fixation of hybrid rTKA tibial components and re-revision total knee arthroplasty for aseptic loosening (rrTKA-AL). All consecutive rTKAs with hybrid tibial components (May 2006 to December 2020) were screened for subsequent rrTKA-AL. A control group was randomly selected from the remaining cohort. Postoperative radiographs of rTKAs were scored in random order by three blinded observers for zonal fixation in the epiphysis (bone resection level below, at, or above fibular head; 0 to 2), metaphysis (number of sufficiently cemented zones; 0 to 4), and diaphysis (canal filling ratio (CFR); %). The intraclass correlation coefficient (ICC) was calculated to quantify the agreement between observers. Multivariate logistic regression analysis was performed to assess the relationship between zonal fixation and rrTKA-AL.Aims
Methods
The Exeter femoral stem has a cemented, polished taper-slip design, and an excellent track record. The current range includes short-length options for various offsets, but less is known about the performance of these stems. The aim of this study was to compare the survival of short-length stems with standard-length Exeter stems. A systematic review of all studies reporting the use of short-length Exeter stems in primary total hip arthroplasty (THA) was undertaken. Survival data, the indication for revision, and patient-reported outcomes were gathered from observational and randomized studies. Studies based on registry data were analyzed separately.Aims
Methods
Limb salvage surgery (LSS) is the primary treatment option for primary bone malignancy. It involves the removal of bone and tissue, followed by reconstruction with endoprosthetic replacements (EPRs) to prevent amputation. Trabecular metal (TM) collars have been developed to encourage bone ingrowth (osseointegration (OI)) into EPRs. The primary aim of this study was to assess whether OI occurs when TM collars are used in EPRs for tumour. A total of 124 patients from July 2010 to August 2021 who underwent an EPR for tumour under the West of Scotland orthopaedic oncology team were identified. Overall, 81 patients (65%) met the inclusion criteria, and two consultants independently analyzed radiographs at three and 12 months, as well as the last radiograph, using a modified version of the Stanford Radiological Assessment System.Aims
Methods