Approximately half of all hip fractures are displaced intracapsular fractures. The standard treatment for these fractures is either hemiarthroplasty or total hip arthroplasty. The recent National Institute for Health and Care Excellence (NICE) guidance on hip fracture management recommends the use of ‘proven’ cemented stem arthroplasty with an Orthopaedic Device Evaluation Panel (ODEP) rating of at least 3B (97% survival at three years). The Thompsons prosthesis is currently lacking an ODEP rating despite over 50 years of clinical use, likely due to the paucity of implant survival data. Nationally, adherence to these guidelines is varied as there is debate as to which prosthesis optimises patient outcomes. This study design is a multi-centre, multi-surgeon, parallel, two arm, standard-of-care pragmatic randomised controlled trial. It will be embedded within the WHiTE Comprehensive Cohort Study (ISRCTN63982700). The main analysis is a two-way equivalence comparison between Hemi-Thompson and Hemi-Exeter polished taper with Unitrax head. Secondary outcomes will include radiological leg length discrepancy measured as per Bidwai and Willett, mortality, re-operation rate and indication for re-operation, length of index hospital stay and revision at four months. This study will be supplemented by the NHFD (National Hip Fracture Database) dataset.Background
Design
We describe the impact of a targeted performance
improvement programme and the associated performance improvement
interventions, on mortality rates, error rates and process of care
for haemodynamically unstable patients with pelvic fractures. Clinical
care and performance improvement data for 185 adult patients with exsanguinating
pelvic trauma presenting to a United Kingdom Major Trauma Centre
between January 2007 and January 2011 were analysed with univariate
and multivariate regression and compared with National data. In
total 62 patients (34%) died from their injuries and opportunities
for improved care were identified in one third of deaths. Three major interventions were introduced during the study period
in response to the findings. These were a massive haemorrhage protocol,
a decision-making algorithm and employment of specialist pelvic
orthopaedic surgeons. Interventions which improved performance were
associated with an annual reduction in mortality (odds ratio 0.64
(95% confidence interval (CI) 0.44 to 0.93), p = 0.02), a reduction
in error rates (p = 0.024) and significant improvements in the targeted
processes of care. Exsanguinating patients with pelvic trauma are
complex to manage and are associated with high mortality rates;
implementation of a targeted performance improvement programme achieved
sustained improvements in mortality, error rates and trauma care
in this group of severely injured patients. Cite this article: