There is little published information on the
health impact of frozen shoulder. The purpose of this study was
to assess the functional and health-related quality of life outcomes
following arthroscopic capsular release (ACR) for contracture of
the shoulder. Between January 2010 and January 2012 all patients
who had failed non-operative treatment including anti-inflammatory
medication, physiotherapy and glenohumeral joint injections for
contracture of the shoulder and who subsequently underwent an ACR
were enrolled in the study. A total of 100 patients were eligible;
68 underwent ACR alone and 32 had ACR with a subacromial decompression
(ASD). ACR resulted in a highly significant improvement in the range
of movement and functional outcome, as measured by the Oxford shoulder
score and EuroQol EQ-5D index. The mean cost of a quality-adjusted
life year (QALY) for an ACR and ACR with an ASD was £2563 and £3189,
respectively. ACR is thus a cost-effective procedure that can restore relatively
normal function and health-related quality of life in most patients
with a contracture of the shoulder within six months after surgery;
and the beneficial effects are not related to the duration of the
presenting symptoms. Cite this article:
There is little information about the management
of peri-prosthetic fracture of the humerus after total shoulder replacement
(TSR). This is a retrospective review of 22 patients who underwent
a revision of their original shoulder replacement for peri-prosthetic
fracture of the humerus with bone loss and/or loose components.
There were 20 women and two men with a mean age of 75 years (61
to 90) and a mean follow-up 42 months (12 to 91): 16 of these had
undergone a previous revision TSR. Of the 22 patients, 12 were treated
with a long-stemmed humeral component that bypassed the fracture.
All their fractures united after a mean of 27 weeks (13 to 94).
Eight patients underwent resection of the proximal humerus with
endoprosthetic replacement to the level of the fracture. Two patients
were managed with a clam-shell prosthesis that retained the original
components. The mean
Scapulothoracic fusion (STF) for painful winging
of the scapula in neuromuscular disorders can provide effective pain
relief and functional improvement, but there is little information
comparing outcomes between patients with dystrophic and non-dystrophic
conditions. We performed a retrospective review of 42 STFs in 34
patients with dystrophic and non-dystrophic conditions using a multifilament
trans-scapular, subcostal cable technique supported by a dorsal
one-third semi-tubular plate. There were 16 males and 18 females
with a mean age of 30 years (15 to 75) and a mean follow-up of 5.0
years (2.0 to 10.6). The mean
A total of 92 patients with symptoms for over
six months due to subacromial impingement of the shoulder, who were
being treated with physiotherapy, were included in this study. While
continuing with physiotherapy they waited a further six months for
surgery. They were divided into three groups based on the following
four clinical and radiological criteria: temporary benefit following
steroid injection, pain in the mid-arc of abduction, a consistently positive
Hawkins test and radiological evidence of impingement. Group A fulfilled
all four criteria, group B three criteria and group C two criteria.
A total of nine patients improved while waiting for surgery and
were excluded, leaving 83 who underwent arthroscopic subacromial
decompression (SAD). The new
Impingement syndrome in the shoulder has generally been considered to be a clinical condition of mechanical origin. However, anomalies exist between the pathology in the subacromial space and the degree of pain experienced. These may be explained by variations in the processing of nociceptive inputs between different patients. We investigated the evidence for augmented pain transmission (central sensitisation) in patients with impingement, and the relationship between pre-operative central sensitisation and the outcomes following arthroscopic subacromial decompression. We recruited 17 patients with unilateral impingement of the shoulder and 17 age- and gender-matched controls, all of whom underwent quantitative sensory testing to detect thresholds for mechanical stimuli, distinctions between sharp and blunt punctate stimuli, and heat pain. Additionally
The combination of an irreparable tear of the rotator cuff and destructive arthritis of the shoulder joint may cause severe pain, disability and loss of independence in the aged. Standard anatomical shoulder replacements depend on a functioning rotator cuff, and hence may fail in the presence of tears in the cuff. Many designs of non-anatomical constrained or semi-constrained prostheses have been developed for cuff tear arthropathy, but have proved unsatisfactory and were abandoned. The DePuy Delta III reverse prosthesis, designed by Grammont, medialises and stabilises the centre of rotation of the shoulder joint and has shown early promise. This study evaluated the mid-term clinical and radiological results of this arthroplasty in a consecutive series of 50 shoulders in 43 patients with a painful pseudoparalysis due to an irreparable cuff tear and destructive arthritis, performed over a period of seven years by a single surgeon. A follow-up of 98% was achieved, with a mean duration of 39 months (8 to 81). The mean age of the patients at the time of surgery was 81 years (59 to 95). The female to male ratio was 5:1. During the seven years, six patients died of natural causes. The clinical outcome was assessed using the American Shoulder and Elbow
There are many types of treatment used to manage the frozen shoulder, but there is no consensus on how best to manage patients with this painful and debilitating condition. We conducted a review of the evidence of the effectiveness of interventions used to manage primary frozen shoulder using the Cochrane Database of Systematic Reviews, the Database of Abstracts of Reviews of Effects, the Physiotherapy Evidence Database, MEDLINE and EMBASE without language or date restrictions up to April 2009. Two authors independently applied selection criteria and assessed the quality of systematic reviews using the Assessment of Multiple Systematic Reviews (AMSTAR) tool. Data were synthesised narratively, with emphasis placed on assessing the quality of evidence. In total, 758 titles and abstracts were identified and screened, which resulted in the inclusion of 11 systematic reviews. Although these met most of the AMSTAR quality criteria, there was insufficient evidence to draw firm conclusions about the effectiveness of treatments commonly used to manage a frozen shoulder. This was mostly due to poor methodological quality and small sample size in primary studies included in the reviews. We found no reviews evaluating surgical interventions. More rigorous randomised trials are needed to evaluate the treatments used for frozen shoulder.
We have compared the outcome of hemiarthroplasty of the shoulder in three distinct diagnostic groups, using survival analysis as used by the United Kingdom national joint registers, patient-reported outcome measures (PROMs) as recommended by Darzi in the 2008 NHS review, and transition and satisfaction questions. A total of 72 hemiarthroplasties, 19 for primary osteoarthritis (OA) with an intact rotator cuff, 22 for OA with a torn rotator cuff, and 31 for rheumatoid arthritis (RA), were followed up for between three and eight years. All the patients survived, with no revisions or dislocations and no significant radiological evidence of loosening. The mean new
We have carried out a prospective double-blind randomised controlled trial to compare the efficacy of a single subacromial injection of the non-steroidal anti-inflammatory drug, tenoxicam, with a single injection of methylprednisolone in patients with subacromial impingement. A total of 58 patients were randomly allocated into two groups. Group A received 40 mg of methylprednisolone and group B 20 mg of tenoxicam as a subacromial injection along with lignocaine. The Constant-Murley shoulder score was used as the primary outcome measure and the Disability of Arm, Shoulder and Hand (DASH) and the
There are no long-term published results on the survival of a third-generation cemented total shoulder replacement. We describe a clinical and radiological study of the Aequalis total shoulder replacement for a minimum of ten years. Between September 1996 and May 1998, 39 consecutive patients underwent a primary cemented total shoulder replacement using this prosthesis. Data were collected prospectively on all patients each year, for a minimum of ten years, or until death or failure of the prosthesis. At a follow-up of at least ten years, 12 patients had died with the prosthesis intact and two had emigrated, leaving 25 available for clinical review. Of these, 13 had rheumatoid arthritis and 12 osteoarthritis. One refused radiological review leaving 24 with fresh radiographs. Survivorship at ten years was 100% for the humeral component and 92% for the glenoid component. The incidence of lucent lines was low. No humeral component was thought to be at risk and only two glenoid components. The osteoarthritic group gained a mean 65° in forward flexion and their Constant score improved by a mean 41.4 points (13 to 55). The rheumatoid group gained a mean of 24° in flexion and their Constant score improved by 29.4 points. This difference may have been due to failure of the rotator cuff in 75% of the patients with rheumatoid arthritis. Thus a third-generation total shoulder replacement gives an excellent result in patients with osteoarthritis and an intact rotator cuff. Patients with rheumatoid arthritis have a 75% risk of failure of the rotator cuff at ten years.
The aim of this study was to investigate genetic influences on the development and progression of tears of the rotator cuff. From a group of siblings of patients with a tear of the rotator cuff and of controls studied five years earlier, we determined the prevalence of tears of the rotator cuff with and without associated symptoms using ultrasound and the
A consecutive series of 372 patients who underwent surgery for disorders of the rotator cuff involving arthroscopic subacromial decompression and open or arthroscopic repairs of the cuff were prospectively investigated as to the comparability of subjective and objective assessment scores of shoulder function. Assessments were made before operation and at 3, 6, 12, 18 and 24 months after surgery using the Disabilities of the Arm, Shoulder, and Hand
The aim of this study was to determine the functional outcome and rate of re-tears following mini-open repair of symptomatic large and massive tears of the rotator cuff using a two-row technique. The 24 patients included in the study were assessed prospectively before and at a mean of 27 months (18 to 53) after surgery using the Constant and the