Advertisement for orthosearch.org.uk
Results 1 - 20 of 1034
Results per page:
Bone & Joint Open
Vol. 6, Issue 2 | Pages 155 - 163
8 Feb 2025
Konishi T Hamai S Kawahara S Hara D Sato T Motomura G Utsunomiya T Nakashima Y

Aims

This study aimed to investigate whether the use of CT-based navigation enhances: 1) the accuracy of cup placement; and 2) the achievement rate of required range of motion (ROM). Additionally, we investigated the impact of using a large femoral head and dual-mobility liner on the achievement rates.

Methods

This retrospective study analyzed 60 manual and 51 CT-based navigated primary total hip arthroplasties performed at a single facility. Postoperative CT scans and CT-based simulation software were employed to measure the cup orientation and to simulate the ROM. We compared the absolute errors for radiological inclination (RI) and radiological anteversion (RA) between the two groups. We also examined whether the simulated ROM met the required ROM criteria, defined as flexion > 110°, internal rotation > 30°, extension > 30°, and external rotation > 30°. Furthermore, we performed simulations with 36 mm femoral head and dual-mobility liner.


Bone & Joint Open
Vol. 6, Issue 2 | Pages 126 - 134
4 Feb 2025
Schneller T Kraus M Schätz J Moroder P Scheibel M Lazaridou A

Aims

Machine learning (ML) holds significant promise in optimizing various aspects of total shoulder arthroplasty (TSA), potentially improving patient outcomes and enhancing surgical decision-making. The aim of this systematic review was to identify ML algorithms and evaluate their effectiveness, including those for predicting clinical outcomes and those used in image analysis.

Methods

We searched the PubMed, EMBASE, and Cochrane Central Register of Controlled Trials databases for studies applying ML algorithms in TSA. The analysis focused on dataset characteristics, relevant subspecialties, specific ML algorithms used, and their performance outcomes.


Bone & Joint Research
Vol. 14, Issue 2 | Pages 77 - 92
4 Feb 2025
Spanninga BJ Hoelen TA Johnson S Cheng B Blokhuis TJ Willems PC Arts JJC

Aims

Autologous bone graft (ABG) is considered the ‘gold standard’ among graft materials for bone regeneration. However, complications including limited availability, donor site morbidity, and deterioration of regenerative capacity over time have been reported. P-15 is a synthetic peptide that mimics the cell binding domain of Type-I collagen. This peptide stimulates new bone formation by enhancing osteogenic cell attachment, proliferation, and differentiation. The objective of this study was to conduct a systematic literature review to determine the clinical efficacy and safety of P-15 peptide in bone regeneration throughout the skeletal system.

Methods

PubMed, Embase, Web of Science, and Cochrane Library were searched for relevant articles on 13 May 2023. The systematic review was reported according to the PRISMA guidelines. Two reviewers independently screened and assessed the identified articles. Quality assessment was conducted using the methodological index for non-randomized studies and the risk of bias assessment tool for randomized controlled trials.


Bone & Joint 360
Vol. 14, Issue 1 | Pages 23 - 26
1 Feb 2025

The February 2025 Foot & Ankle Roundup360 looks at:Percutaneous Zadek osteotomy for insertional Achilles tendinopathy; Association of extraosseous arterial diameter with talar dome osteochondral lesions; Autologous chondrocyte implantation for osteochondral lesions of the talus; Symptomatic thromboembolism and mortality in foot and ankle surgery in the UK; Corticosteroid or hyaluronic acid in Morton’s neuroma?


Bone & Joint Research
Vol. 14, Issue 2 | Pages 69 - 76
1 Feb 2025
Tripon M Lalevee M van Rooij F Agu C Saffarini M Beaudet P

Aims

To evaluate how fore- and midfoot coronal plane alignment differs in feet with hallux valgus (HV), using 3DCT when measured in standard weightbearing (SWB) versus sesamoid view (SV) position, and to determine whether first metatarsophalangeal (MTP) dorsiflexion affects the relationship between the first metatarsal (M1) head and the sesamoid bones.

Methods

A consecutive series of 34 feet that underwent 3DCT in SWB and SV positions for symptomatic HV was assessed, of which four feet were excluded for distorted or incomplete images. Two foot and ankle clinicians independently digitized a series of points, and measured a series of angles according to a pre-defined protocol. Measurements include navicular pronation angle, M1 head (Saltzman angle), and metatarsosesamoid rotation angle (MSRA).


Bone & Joint 360
Vol. 14, Issue 1 | Pages 39 - 42
1 Feb 2025

The February 2025 Oncology Roundup360 looks at:The role of bone grafting versus bone cement in the treatment of giant cell tumour of bone: a systematic review and meta-analysis on the risk of recurrence in 1,454 patients; Tumour necrosis drives prognosis in osteosarcoma; Correlation between post-chemotherapy MRI and histopathology of malignant bone tumours treated with extra-articular resection; Real-world referral pattern of unplanned excision in patients with soft-tissue sarcoma; Assessment of artificial intelligence chatbot responses to common patient questions on bone sarcoma; Chondrosarcoma of the pelvis and limbs at ten years; Chest wall resection and reconstruction for primary chest wall sarcomas: analysis of survival, predictors of outcome, and long-term functional status; Ewing’s sarcoma in the paediatric population: predictors of survival within the USA; Pulmonary metastasectomy for sarcoma: insights from a referral centre cohort.


Bone & Joint 360
Vol. 14, Issue 1 | Pages 33 - 36
1 Feb 2025

The February 2025 Spine Roundup360 looks at: The effect of thoraco-lumbo-sacral orthosis wear time and clinical risk factors on curve progression for individuals with adolescent idiopathic scoliosis; Does operative level impact dysphagia severity after anterior cervical discectomy and fusion? A multicentre prospective analysis; Who gets better after surgery for degenerative cervical myelopathy? A responder analysis from the multicentre Canadian spine outcomes and research network; Do obese patients have worse outcomes in adult spinal deformity surgeries?; An update to the management of spinal cord injury; Classifying thoracolumbar injuries; High- versus moderate-density constructs in adolescent idiopathic scoliosis are equivalent at two years; Romosozumab for protecting against proximal junctional kyphosis in deformity surgery.


The Bone & Joint Journal
Vol. 107-B, Issue 2 | Pages 213 - 220
1 Feb 2025
Zheng Z Ryu BY Kim SE Song DS Kim SH Park J Ro DH

Aims

The aim of this study was to develop and evaluate a deep learning-based model for classification of hip fractures to enhance diagnostic accuracy.

Methods

A retrospective study used 5,168 hip anteroposterior radiographs, with 4,493 radiographs from two institutes (internal dataset) for training and 675 radiographs from another institute for validation. A convolutional neural network (CNN)-based classification model was trained on four types of hip fractures (Displaced, Valgus-impacted, Stable, and Unstable), using DAMO-YOLO for data processing and augmentation. The model’s accuracy, sensitivity, specificity, Intersection over Union (IoU), and Dice coefficient were evaluated. Orthopaedic surgeons’ diagnoses served as the reference standard, with comparisons made before and after artificial intelligence assistance.


Bone & Joint Research
Vol. 14, Issue 1 | Pages 58 - 68
27 Jan 2025
Pelleg-Kallevag R Borgel S Kedar E Peled N May H

Aims

The development of lumbar lordosis has been traditionally examined using angular measurements of the spine to reflect its shape. While studies agree regarding the increase in the angles during growth, the growth rate is understudied, and sexual dimorphism is debated. In this study, we used a novel method to estimate the shape of the lumbar curve (LC) using the landmark-based geometric morphometric method to explore changes in LC during growth, examine the effect of size and sex on LC shape, and examine the associations between angular measurements and shape.

Methods

The study population included 258 children aged between 0 and 20 years (divided into five age groups) who underwent a CT scan between the years 2009 and 2019. The landmark-based geometric morphometric method was used to capture the LC shape in a sagittal view. Additionally, the lordosis was measured via Cobb and sacral slope angles. Multivariate and univariate statistical analyses were carried out to examine differences in shape between males and females and between the age groups.


Bone & Joint Research
Vol. 14, Issue 1 | Pages 33 - 41
17 Jan 2025
Fujimoto K Kanamoto T Otani S Miyazaki R Ebina K Nakata K

Aims

Ultrasound-guided injection techniques are expected to enhance therapeutic efficacy for skeletal muscle injuries and disorders, but basic knowledge is lacking. The purpose of this study was to examine the diagnostic accuracy of ultrasound for abnormal skeletal muscle lesions, and to examine the distribution patterns of solution and cells injected into abnormal muscle lesions under ultrasound guidance.

Methods

A cardiotoxin (CTX)-induced muscle injury model was used. Briefly, CTX was injected into tibialis anterior muscle in rats under ultrasound observation. First, the diagnostic accuracy of abnormal muscle lesions on ultrasound was examined by comparing ultrasound findings and histology. Next, Fast Green solution and green fluorescent protein (GFP)-labelled cells were simultaneously injected into the abnormal muscle lesions under ultrasound guidance, and their distribution was evaluated.


Bone & Joint Research
Vol. 14, Issue 1 | Pages 20 - 32
17 Jan 2025
Chen Z Zhou T Yin Z Duan P Zhang Y Feng Y Shi R Xu Y Pang R Tan H

Aims

Magnesium ions (Mg2+) play an important role in promoting cartilage repair in cartilage lesions. However, no research has focused on the role of Mg2+ combined with microfracture (MFX) in hyaline-like cartilage repair mediated by cartilage injury. This study aimed to investigate the beneficial effects of the combination of MFX and Mg2+ in cartilage repair.

Methods

A total of 60 rabbits were classified into five groups (n = 12 each): sham, MFX, and three different doses of Mg2+ treatment groups (0.05, 0.5, and 5 mol/L). Bone cartilage defects were created in the trochlear groove cartilage of rabbits. MFX surgery was performed after osteochondral defects. Mg2+ was injected into knee joints immediately and two and four weeks after surgery. At six and 12 weeks after surgery, the rabbits were killed. Cartilage damage was detected by gross observation, micro-CT, and histological analysis. The expression levels of related genes were detected by real-time quantitative reverse transcription polymerase chain reaction (RT-qPCR).


Bone & Joint Open
Vol. 6, Issue 1 | Pages 93 - 102
15 Jan 2025
Kawai T Nishitani K Okuzu Y Goto K Kuroda Y Kuriyama S Nakamura S Matsuda S

Aims. This study was performed to investigate the association between the acetabular morphology and the joint space narrowing rate (JSNR) in the non-arthritic hip. Methods. We retrospectively reviewed standing whole-leg radiographs of patients who underwent knee arthroplasty from February 2012 to March 2020 at our institute. Patients with a history of hip surgery, Kellgren-Lawrence grade ≥ II hip osteoarthritis, or rheumatoid arthritis were excluded. The hip JSNR was measured, and the normalized JSNR (nJSNR) was calculated by calibrating the joint space width with the size of the femoral head in 395 patients (790 hips) with a mean age of 73.7 years (SD 8.6). The effects of the lateral centre-edge angle (CEA) and acetabular roof obliquity (ARO) in the standing and supine positions were examined using a multivariate regression model. Results. The mean JSNR and nJSNR were 0.115 mm/year (SD 0.181) and 2.451 mm/year (SD 3.956), respectively. Multivariate regressions showed that older age was associated with a larger nJSNR (p = 0.010, standardized coefficient (SC) 0.096). The quadratic curve approximation showed that the joint space narrowing was smallest when the CEA was approximately 31.9°. This optimal CEA was the same in the standing and supine positions. Multivariate regressions were separately performed for joints with a CEA of < 31.9° and > 31.9°. When the CEA was < 31.9°, a smaller CEA was associated with a larger nJSNR (p < 0.001, SC 0.282). When the CEA was > 31.9°, a larger CEA was associated with a larger nJSNR (p = 0.012, SC 0.152). The ARO was not associated with the nJSNR. Conclusion. Both insufficient coverage and over-coverage of the acetabulum over the femoral head were associated with increased joint space narrowing in hips that were non-arthritic at baseline. The effects of insufficient coverage were stronger than those of overcoverage. Cite this article: Bone Jt Open 2025;6(1):93–102


Bone & Joint Open
Vol. 6, Issue 1 | Pages 35 - 42
8 Jan 2025
Fischer M Nonnenmacher L Hofer A Zimmerer A Nitsch A Großjohann R Erdmann S Wassilew GI

Aims

Periacetabular osteotomy (PAO) is well established for acetabular reorientation and has shown successful improvement in patient-reported outcome measures (PROMs). Nevertheless, studies focusing on postoperative outcomes related to patient individual factors are still underrepresented. Therefore, this study aimed to analyze the functional outcome and activity level in relation to patient sex with a minimum follow-up of two years after PAO for mild to severe hip dysplasia.

Methods

A single-centre study was conducted, enrolling patients undergoing PAO and completing a preoperative and postoperative radiological and clinical outcome assessment. The PROMs were assessed using the modified Harris Hip Score (mHHS), the Hip disability and Osteoarthritis Outcome Score (HOOS) with the subscales for pain, sport, activities of daily living (ADL), and quality of life (QoL), and the University of California, Los Angeles (UCLA) activity score. Kendall’s tau were calculated for correlation analyses.


The Bone & Joint Journal
Vol. 107-B, Issue 1 | Pages 97 - 102
1 Jan 2025
Smeitink N Schröder FF Dorrestijn O Spekenbrink-Spooren A Govaert LHM Veen EJD

Aims

Hemiarthroplasty (HA) and total shoulder arthroplasty (TSA) are often the preferred forms of treatment for patients with atraumatic avascular necrosis of the humeral head when conservative treatment fails. Little has been reported about the survival of HA and TSA for this indication. The aim of this study was to investigate the differences in revision rates between HA and TSA in these patients, to determine whether one of these implants has a superior survival and may be a better choice in the treatment of this condition.

Methods

Data from 280 shoulders with 159 primary HAs and 121 TSAs, which were undertaken in patients with atraumatic avascular necrosis of the humeral head between January 2014 and January 2023 from the Dutch Arthroplasty Register (LROI), were included. Kaplan-Meier survival analysis and Cox regression analysis were undertaken.


The Bone & Joint Journal
Vol. 107-B, Issue 1 | Pages 124 - 132
1 Jan 2025
Thompson P Khattak M Joseph PJ Perry DC Cootes TF Lindner C

Aims

The aims of this study were to develop an automatic system capable of calculating four radiological measurements used in the diagnosis and monitoring of cerebral palsy (CP)-related hip disease, and to demonstrate that these measurements are sufficiently accurate to be used in clinical practice.

Methods

We developed a machine-learning system to automatically measure Reimer’s migration percentage (RMP), acetabular index (ACI), head shaft angle (HSA), and neck shaft angle (NSA). The system automatically locates points around the femoral head and acetabulum on pelvic radiographs, and uses these to calculate measurements. The system was evaluated on 1,650 pelvic radiographs of children with CP (682 females and 968 males, mean age 8.3 years (SD 4.5)). Each radiograph was manually measured by five clinical experts. Agreement between the manual clinical measurements and the automatic system was assessed by mean absolute deviation (MAD) from the mean manual measurement, type 1 and type 2 intraclass correlation coefficients (ICCs), and a linear mixed-effects model (LMM) for assessing bias.


Bone & Joint Research
Vol. 13, Issue 12 | Pages 764 - 778
12 Dec 2024
Huang Q Zhuo Y Duan Z Long Y Wang J Zhang Z Fan S Huang Y Deng K Xin H

Aims

Mesenchymal stem cells (MSCs) are usually cultured in a normoxic atmosphere (21%) in vitro, while the oxygen concentrations in human tissues and organs are 1% to 10% when the cells are transplanted in vivo. However, the impact of hypoxia on MSCs has not been deeply studied, especially its translational application.

Methods

In the present study, we investigated the characterizations of human umbilical cord-derived mesenchymal stem cells (hUC-MSCs) in hypoxic (1%) and normoxic (21%) atmospheres with a long-term culture from primary to 30 generations, respectively. The comparison between both atmospheres systematically analyzed the biological functions of MSCs, mainly including stemness maintenance, immune regulation, and resistance to chondrocyte apoptosis, and studied their joint function and anti-inflammatory effects in osteoarthritis (OA) rats constructed by collagenase II.


Aims

Functional alignment (FA) in total knee arthroplasty (TKA) aims to achieve balanced gaps by adjusting implant positioning while minimizing changes to constitutional joint line obliquity (JLO). Although FA uses kinematic alignment (KA) as a starting point, the final implant positions can vary significantly between these two approaches. This study used the Coronal Plane Alignment of the Knee (CPAK) classification to compare differences between KA and final FA positions.

Methods

A retrospective analysis compared pre-resection and post-implantation alignments in 2,116 robotic-assisted FA TKAs. The lateral distal femoral angle (LDFA) and medial proximal tibial angle (MPTA) were measured to determine the arithmetic hip-knee-ankle angle (aHKA = MPTA – LDFA), JLO (JLO = MPTA + LDFA), and CPAK type. The primary outcome was the proportion of knees that varied ≤ 2° for aHKA and ≤ 3° for JLO from their KA to FA positions, and direction and magnitude of those changes per CPAK phenotype. Secondary outcomes included proportion of knees that maintained their CPAK phenotype, and differences between sexes.


Bone & Joint Research
Vol. 13, Issue 12 | Pages 725 - 740
5 Dec 2024
Xing J Liu S

Addressing bone defects is a complex medical challenge that involves dealing with various skeletal conditions, including fractures, osteoporosis (OP), bone tumours, and bone infection defects. Despite the availability of multiple conventional treatments for these skeletal conditions, numerous limitations and unresolved issues persist. As a solution, advancements in biomedical materials have recently resulted in novel therapeutic concepts. As an emerging biomaterial for bone defect treatment, graphene oxide (GO) in particular has gained substantial attention from researchers due to its potential applications and prospects. In other words, GO scaffolds have demonstrated remarkable potential for bone defect treatment. Furthermore, GO-loaded biomaterials can promote osteoblast adhesion, proliferation, and differentiation while stimulating bone matrix deposition and formation. Given their favourable biocompatibility and osteoinductive capabilities, these materials offer a novel therapeutic avenue for bone tissue regeneration and repair. This comprehensive review systematically outlines GO scaffolds’ diverse roles and potential applications in bone defect treatment.

Cite this article: Bone Joint Res 2024;13(12):725–740.


Bone & Joint Open
Vol. 5, Issue 12 | Pages 1067 - 1071
2 Dec 2024
Salzmann M Kropp E Prill R Ramadanov N Adriani M Becker R

Aims

The transepicondylar axis is a well-established reference for the determination of femoral component rotation in total knee arthroplasty (TKA). However, when severe bone loss is present in the femoral condyles, rotational alignment can be more complicated. There is a lack of validated landmarks in the supracondylar region of the distal femur. Therefore, the aim of this study was to analyze the correlation between the surgical transepicondylar axis (sTEA) and the suggested dorsal cortex line (DCL) in the coronal plane and the inter- and intraobserver reliability of its CT scan measurement.

Methods

A total of 75 randomly selected CT scans were measured by three experienced surgeons independently. The DCL was defined in the coronal plane as a tangent to the dorsal femoral cortex located 75 mm above the joint line in the frontal plane. The difference between sTEA and DCL was calculated. Descriptive statistics and angulation correlations were generated for the sTEA and DCL, as well as for the distribution of measurement error for intra- and inter-rater reliability.


The Bone & Joint Journal
Vol. 106-B, Issue 12 | Pages 1399 - 1407
1 Dec 2024
Fujii M Tanaka S Kawano S Ueno M Nagamine S Mawatari M

Aims

This study aimed to determine clinical outcomes; relationships between postoperative anterior, lateral, and posterior acetabular coverage and joint survival; and prognostic factors for joint survival after transposition osteotomy of the acetabulum (TOA).

Methods

Data from 616 patients (800 hips) with hip dysplasia who underwent TOA between November 1998 and December 2019 were reviewed. The median follow-up period was 8.9 years (IQR 5 to 14). A medical notes review was conducted to collect demographic data, complications, and modified Harris Hip Score (mHHS). Radiological indicators of acetabular coverage included lateral centre-edge angle (LCEA), anterior wall index (AWI), and posterior wall index (PWI). The cumulative probability of TOA failure (progression to Tönnis grade 3 or conversion to total hip arthroplasty) was estimated using the Kaplan-Meier product-limited method. A multivariate Cox proportional hazards model was used to identify predictors for failure.