To evaluate if, for orthopaedic trainees, additional cadaveric simulation training or standard training alone yields superior radiological and clinical outcomes in patients undergoing dynamic hip screw (DHS) fixation or hemiarthroplasty for hip fracture. This was a preliminary, pragmatic, multicentre, parallel group randomized controlled trial in nine secondary and tertiary NHS hospitals in England. Researchers were blinded to group allocation. Overall, 40 trainees in the West Midlands were eligible: 33 agreed to take part and were randomized, five withdrew after randomization, 13 were allocated cadaveric training, and 15 were allocated standard training. The intervention was an additional two-day cadaveric simulation course. The control group received standard on-the-job training. Primary outcome was implant position on the postoperative radiograph: tip-apex distance (mm) (DHS) and leg length discrepancy (mm) (hemiarthroplasty). Secondary clinical outcomes were procedure time, length of hospital stay, acute postoperative complication rate, and 12-month mortality. Procedure-specific secondary outcomes were intraoperative radiation dose (for DHS) and postoperative blood transfusion requirement (hemiarthroplasty).Aims
Methods
There is no consensus on the treatment of proximal humeral fractures. Hemiarthroplasty has been widely used in patients when non-surgical treatment is not possible. There is, despite extensive use, limited information about the long-term outcome. Our primary aim was to report ten-year patient-reported outcome after hemiarthroplasty for acute proximal humeral fractures. The secondary aims were to report the cumulative revision rate and risk factors for an inferior patient-reported outcome. We obtained data on 1,371 hemiarthroplasties for acute proximal humeral fractures from the Danish Shoulder Arthroplasty Registry between 2006 and 2010. Of these, 549 patients (40%) were alive and available for follow-up. The Western Ontario Osteoarthritis of the Shoulder (WOOS) questionnaire was sent to all patients at nine to 14 years after primary surgery. Revision rates were calculated using the Kaplan-Meier method. Risk factors for an inferior WOOS score were analyzed using the linear regression model.Aims
Methods
There is a lack of long-term data for minimally invasive acromioclavicular (AC) joint repair. Furthermore, it is not clear if good early clinical results can be maintained over time. The purpose of this study was to report long-term results of minimally invasive AC joint reconstruction (MINAR) and compare it to corresponding short-term data. We assessed patients with a follow-up of at least five years after minimally invasive flip-button repair for high-grade AC joint dislocation. The clinical outcome was evaluated using the Constant score and a questionnaire. Ultrasound determined the coracoclavicular (CC) distance. Results of the current follow-up were compared to the short-term results of the same cohort.Aims
Methods
Complex displaced osteoporotic acetabular fractures in the elderly are associated with high levels of morbidity and mortality. Surgical options include either open reduction and internal fixation alone, or combined with total hip arthroplasty (THA). There remains a cohort of severely comorbid patients who are deemed unfit for extensive surgical reconstruction and are treated conservatively. We describe the results of a coned hemipelvis reconstruction and THA inserted via a posterior approach to the hip as the primary treatment for this severely high-risk cohort. We have prospectively monitored a series of 22 cases (21 patients) with a mean follow-up of 32 months (13 to 59).Aims
Methods
This study describes and compares the operative management and outcomes in a consecutive case series of patients with dislocated hemiarthroplasties of the hip, and compares outcomes with those of patients not sustaining a dislocation. Of 3326 consecutive patients treated with hemiarthroplasty for fractured neck of femur, 46 (1.4%) sustained dislocations. Of the 46 dislocations, there were 37 female patients (80.4%) and nine male patients (19.6%) with a mean age of 83.8 years (66 to 100). Operative intervention for each, and subsequent dislocations, were recorded. The following outcome measures were recorded: dislocation; mortality up to one-year post-injury; additional surgery; residential status; mobility; and pain score at one year.Aims
Patients and Methods
We compared the accuracy, operating time and radiation exposure
of the introduction of iliosacral screws using O-arm/Stealth Navigation
and standard fluoroscopy. Iliosacral screws were introduced percutaneously into the first
sacral body (S1) of ten human cadavers, four men and six women.
The mean age was 77 years (58 to 85). Screws were introduced using
a standard technique into the left side of S1 using C-Arm fluoroscopy
and then into the right side using O-Arm/Stealth Navigation. The
radiation was measured on the surgeon by dosimeters placed under
a lead thyroid shield and apron, on a finger, a hat and on the cadavers.Aims
Materials and Methods
Controversy surrounds the management of displaced
three- and four-part fractures of the proximal humerus. The percutaneous
Resch technique of stabilisation involves minimal soft-tissue dissection
and a reduced risk of stiffness and avascular necrosis. However,
it requires a second operation to remove Kirschner wires and the
humeral block. We describe a modification of this technique that
dispenses with the need for this second operation and relies on
a sequential pattern of screw placement. We report the outcome of
32 three- or four-part fractures of the proximal humerus treated
in this way at a mean follow-up of 3.8 years (2 to 8)). There were
14 men and 18 women with a mean age of 56 years (28 to 83). At final
follow-up the mean Oxford shoulder scores were 38 (31 to 44) and
39 (31 to 42), and the mean Constant scores were 79 (65 to 92) and
72 (70 to 80) for three- and four-part fractures, respectively. We
further analysed the results in patients aged <
60 years with
high-energy fractures and those aged ≥ 60 years with osteoporotic
fractures. There were no cases of nonunion or avascular necrosis. The results were good and comparable to those previously reported
for the Resch technique and other means of fixation for proximal
humeral fractures. We would recommend this modification of the technique
for the treatment of displaced three-part and four-part fractures
in patients both younger and older than 60 years of age.
Using data from the Norwegian Hip Fracture Register,
8639 cemented and 2477 uncemented primary hemiarthroplasties for
displaced fractures of the femoral neck in patients aged > 70 years
were included in a prospective observational study. A total of 218
re-operations were performed after cemented and 128 after uncemented
procedures. Survival of the hemiarthroplasties was calculated using
the Kaplan-Meier method and hazard rate ratios (HRR) for revision
were calculated using Cox regression analyses. At five years the
implant survival was 97% (95% confidence interval (CI) 97 to 97)
for cemented and 91% (95% CI 87 to 94) for uncemented hemiarthroplasties.
Uncemented hemiarthroplasties had a 2.1 times increased risk of
revision compared with cemented prostheses (95% confidence interval
1.7 to 2.6, p < 0.001). The increased risk was mainly caused
by revisions for peri-prosthetic fracture (HRR = 17), aseptic loosening
(HRR = 17), haematoma formation (HRR = 5.3), superficial infection
(HRR = 4.6) and dislocation (HRR = 1.8). More intra-operative complications,
including intra-operative death, were reported for the cemented
hemiarthroplasties. However, in a time-dependent analysis, the HRR
for re-operation in both groups increased as follow-up increased. This study showed that the risk for revision was higher for uncemented
than for cemented hemiarthroplasties.
We treated 47 patients with a mean age of 57 years (22 to 88) who had a proximal humeral fracture in which there was a severe varus deformity, using a standard operative protocol of anatomical reduction, fixation with a locking plate and supplementation by structural allografts in unstable fractures. The functional and radiological outcomes were reviewed. At two years after operation the median Constant score was 86 points and the median Disabilities of the Arm, Shoulder and Hand score 17 points. Seven of the patients underwent further surgery, two for failure of fixation, three for dysfunction of the rotator cuff, and two for shoulder stiffness. The two cases of failure of fixation were attributable to violation of the operative protocol. In the 46 patients who retained their humeral head, all the fractures healed within the first year, with no sign of collapse or narrowing of the joint space. Longer follow-up will be required to confirm whether these initially satisfactory results are maintained.
In a randomised prospective study, 20 patients with intra-articular fractures of the distal radius underwent arthroscopically- and fluoroscopically-assisted reduction and external fixation plus percutaneous pinning. Another group of 20 patients with the same fracture characteristics underwent fluoroscopically-assisted reduction alone and external fixation plus percutaneous pinning. The patients were evaluated clinically and radiologically at follow-up of 24 months. The Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire and modified Mayo wrist score were used at 3, 9, 12 and 24 months postoperatively. In the arthroscopically- and fluoroscopically-assisted group, triangular fibrocartilage complex tears were found in 12 patients (60%), complete or incomplete scapholunate ligament tears in nine (45%), and lunotriquetral ligament tears in four (20%). They were treated either arthroscopically or by open operation. Patients who underwent arthroscopically- and fluoroscopically-assisted treatment had significantly better supination, extension and flexion at all time points than those who had fluoroscopically-assisted surgery. The mean DASH scores were similar for both groups at 24 months, whereas the difference in the mean modified Mayo wrist scores remained statistically significant. Although the groups are small, it is clear that the addition of arthroscopy to the fluoroscopically-assisted treatment of intra-articular distal radius fractures improves the outcome. Better treatment of associated intra-articular injuries might also have been a reason for the improved outcome.
We used an inverted shoulder arthroplasty in 43 consecutive patients with a mean age of 78 years (65 to 97) who had sustained a three- or four-part fracture of the upper humerus. All except two were reviewed with a mean follow-up of 22 months (6 to 58). The clinical outcome was satisfactory with a mean active anterior elevation of 97° (35° to 160°) and a mean active external rotation in abduction of 30° (0° to 80°). The mean Constant and the mean modified Constant scores were respectively 44 (16 to 69) and 66% (25% to 97%). Complications included three patients with reflex sympathetic dystrophy, five with neurological complications, most of which resolved, and one with an anterior dislocation. Radiography showed peri-prosthetic calcification in 36 patients (90%), displacement of the tuberosities in 19 (53%) and a scapular notch in ten (25%). Compared with conventional hemiarthroplasty, satisfactory mobility was obtained despite frequent migration of the tuberosities. However, long-term results are required before reverse shoulder arthroplasty can be recommended as a routine procedure in complex fractures of the upper humerus in the elderly.