Advertisement for orthosearch.org.uk
Results 1 - 9 of 9
Results per page:

Aims

The primary aim of this study was to report the radiological outcomes of patients with a dorsally displaced distal radius fracture who were randomized to a moulded cast or surgical fixation with wires following manipulation and closed reduction of their fracture. The secondary aim was to correlate radiological outcomes with patient-reported outcome measures (PROMs) in the year following injury.

Methods

Participants were recruited as part of DRAFFT2, a UK multicentre clinical trial. Participants were aged 16 years or over with a dorsally displaced distal radius fracture, and were eligible for the trial if they needed a manipulation of their fracture, as recommended by their treating surgeon. Participants were randomly allocated on a 1:1 ratio to moulded cast or Kirschner wires after manipulation of the fracture in the operating theatre. Standard posteroanterior and lateral radiographs were performed in the radiology department of participating centres at the time of the patient’s initial assessment in the emergency department and six weeks postoperatively. Intraoperative fluoroscopic images taken at the time of fracture reduction were also assessed.


The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1225 - 1233
1 Nov 2022
Png ME Petrou S Achten J Ooms A Lamb SE Hedley H Dias J Costa ML

Aims

The aim of this study was to compare the cost-effectiveness of surgical fixation with Kirschner (K-)wire ersus moulded casting after manipulation of a fracture of the distal radius in an operating theatre setting.

Methods

An economic evaluation was conducted based on data collected from the Distal Radius Acute Fracture Fixation Trial 2 (DRAFFT2) multicentre randomized controlled trial in the UK. Resource use was collected at three, six, and 12 months post-randomization using trial case report forms and participant-completed questionnaires. Cost-effectiveness was reported in terms of incremental cost per quality-adjusted life year (QALY) gained from an NHS and personal social services perspective. Sensitivity analyses were conducted to examine the robustness of cost-effectiveness estimates, and decision uncertainty was handled using confidence ellipses and cost-effectiveness acceptability curves.


The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 709 - 714
1 Jun 2022
Stirling PHC Simpson CJ Ring D Duckworth AD McEachan JE

Aims

The aim of this study was to describe the introduction of a virtual pathway for the management of patients with a suspected fracture of the scaphoid, and to report patient-reported outcome measures (PROMs) and satisfaction following treatment using this service.

Methods

All adult patients who presented with a clinically suspected scaphoid fracture that was not visible on radiographs at the time of presentation during a one-year period were eligible for inclusion in the pathway. Demographic details, findings on examination, and routine four-view radiographs at the time of presentation were collected. All radiographs were reviewed virtually by a single consultant hand surgeon, with patient-initiated follow-up on request. PROMs were assessed at a minimum of one year after presentation and included the abbreviated version of the Disabilities of the Arm, Shoulder and Hand Score (QuickDASH), the EuroQol five-dimension five-level health questionnaire (EQ-5D-5L), the Net Promoter Score (NPS), and return to work.


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1277 - 1283
1 Jul 2021
Hinde S Richardson G Fairhurst C Brealey SD Cook L Rangan A Costa ML Dias JJ

Aims

The aim of the Scaphoid Waist Internal Fixation for Fractures Trial (SWIFFT) was to determine the optimal treatment for adults with a bicortical undisplaced or minimally displaced fracture of the waist of the scaphoid, comparing early surgical fixation with initial cast immobilization, with immediate fixation being offered to patients with nonunion.

Methods

A cost-effectiveness analysis was conducted to assess the relative merits of these forms of treatment. The differences in costs to the healthcare system and quality-adjusted life years (QALYs) of the patients over the one-year follow-up of the trial in the two treatment arms were estimated using regression analysis.


The Bone & Joint Journal
Vol. 102-B, Issue 11 | Pages 1542 - 1548
2 Nov 2020
Stirling PHC Oliver WM Ling Tan H Brown IDM Oliver CW McQueen MM Molyneux SG Duckworth AD

Aims. The primary aim of this study was to describe patient satisfaction and health-related quality of life (HRQoL) following corrective osteotomy for a symptomatic malunion of the distal radius. Methods. We retrospectively identified 122 adult patients from a single centre over an eight-year period who had undergone corrective osteotomy for a symptomatic malunion of the distal radius. The primary long-term outcome was the Patient-Rated Wrist Evaluation (PRWE) score. Secondary outcomes included the Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH) score, the EQ-5D-5L score, complications, and the Net Promoter Score (NPS). Multivariate regression analysis was used to determine factors associated with the PRWE score. Results. Long-term outcomes were available for 89 patients (72%). The mean age was 57 years (SD 15) and 68 were female (76%). The median time from injury to corrective osteotomy was nine months (interquartile range (IQR) 6 to 13). At a mean follow-up of six years (1 to 11) the median PRWE score was 22 (IQR 7 to 40), the median QuickDASH score was 11.4 (IQR 2.3 to 31.8), and the median EQ-5D-5L score was 0.84 (IQR 0.69 to 1). The NPS was 69. Multivariate regression analysis showed that the presence of an associated ulnar styloid fracture was the only significant independent factor associated with a worse PRWE score when adjusting for confounding variables (p = 0.004). Conclusion. We found that corrective osteotomy for malunion of the distal radius can result in good functional outcomes and high levels of patient satisfaction. However, the presence of an ulnar styloid fracture may adversely affect function. Level of Evidence: III (cohort study). Cite this article: Bone Joint J 2020;102-B(11):1542–1548


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1263 - 1271
1 Oct 2019
Eisenschenk A Spitzmüller R Güthoff C Obladen A Kim S Henning E Dornberger JE Stengel D

Aims. The aim of this study was to investigate whether clinical and radiological outcomes after intramedullary nailing of displaced fractures of the fifth metacarpal neck using a single thick Kirschner wire (K-wire) are noninferior to those of technically more demanding fixation with two thinner dual wires. Patients and Methods. This was a multicentre, parallel group, randomized controlled noninferiority trial conducted at 12 tertiary trauma centres in Germany. A total of 290 patients with acute displaced fractures of the fifth metacarpal neck were randomized to either intramedullary single-wire (n = 146) or dual-wire fixation (n = 144). The primary outcome was the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire six months after surgery, with a third of the minimal clinically important difference (MCID) used as the noninferiority threshold. Secondary outcomes were pain, health-related quality of life (EuroQol five-dimensional questionnaire (EQ-5D)), radiological measures, functional deficits, and complications. Results. Overall, 151/290 of patients (52%) completed the six months of follow-up, leaving 83 patients in the single-wire group and 68 patients in the dual-wire group. In the modified intention-to-treat analysis set, mean DASH scores six months after surgery were 3.8 (. sd. 7.0) and 4.4 (. sd. 9.4), respectively. With multiple imputation (n = 288), mean DASH scores were estimated at 6.3 (. sd. 8.7) and 7.0 (. sd. 10.0). Upper (1 - 2α)) confidence limits consistently remained below the noninferiority margin of 3.0 points in the DASH instrument. While there was a statistically nonsignificant trend towards a higher rate of shortening and rotational malalignment in the single wire group, no statistically significant differences were observed across groups in any secondary outcome measure. Conclusion. A single thick K-wire is sufficient for intramedullary fixation of acute displaced subcapital fractures of the fifth metacarpal neck. The less technically demanding single-wire technique produces noninferior clinical and radiological outcomes compared with the dual-wire approach. Cite this article: Bone Joint J 2019;101-B:1263–1271


Aims. The aim of this study was to compare the clinical effectiveness of Kirschner wire (K-wire) fixation with locking-plate fixation for patients with a dorsally displaced fracture of the distal radius in the five years after injury. Patients and Methods. We report the five-year follow-up of a multicentre, two-arm, parallel-group randomized controlled trial. A total of 461 adults with a dorsally displaced fracture of the distal radius within 3 cm of the radiocarpal joint that required surgical fixation were recruited from 18 trauma centres in the United Kingdom. Patients were excluded if the surface of the wrist joint was so badly displaced it required open reduction. In all, 448 patients were randomized to receive either K-wire fixation or locking-plate fixation. In the K-wire group, there were 179 female and 38 male patients with a mean age of 59.1 years (19 to 89). In the locking-plate group, there were 194 female and 37 male patients with a mean age of 58.3 years (20 to 89). The primary outcome measure was the patient-rated wrist evaluation (PRWE). Secondary outcomes were health-related quality of life using the EuroQol five-dimension three-level (EQ-5D-3L) assessment, and further surgery related to the index fracture. Results. At 12 months, 402/448 participants (90%) recruited into the main study provided PRWE scores. At year two, 294 participants (66%) provided scores; at year five, 198 participants (44%) provided scores. There was no clinically relevant difference in the PRWE at any point during the five-year follow-up; at five years, the PRWE score was 8.3 (12.5) in the wire group and 11.3 (15.6) in the plate group (95% confidence interval -6.99 to 0.99; p = 0.139). Nor was there a clinically relevant difference in health-related quality of life. Only three participants had further surgery in the five years after their injury (one in the wire group and two in the plate group). Conclusion. This follow-up study continues to show no evidence of a difference in wrist pain, wrist function, or quality of life for patients treated with wires versus locking plates in the five years following a dorsally displaced fracture of the distal radius. Cite this article: Bone Joint J 2019;101-B:978–983


The Bone & Joint Journal
Vol. 99-B, Issue 3 | Pages 376 - 382
1 Mar 2017
Plant CE Parsons NR Costa ML

Aims

We conducted a study to determine whether radiological parameters correlate with patient reported functional outcome, health-related quality of life and physical measures of function in patients with a fracture of the distal radius.

Patients and Methods

The post-operative palmar tilt and ulnar variance at six weeks and 12 months were correlated with the Patient Rated Wrist Evaluation, Disabilities of the Arm, Shoulder and Hand, and EuroQol scores, grip strength, pinch strength and range of movement at three, six and 12 months for 50 patients (mean age 57 years; 26 to 85) having surgical fixation, with either percutaneous pinning or reconstruction with a volar plate, for a fracture of the distal radius.


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1082 - 1089
1 Aug 2015
Tubeuf S Yu G Achten J Parsons NR Rangan A Lamb SE Costa ML

We present an economic evaluation using data from the Distal Radius Acute Fracture Fixation Trial (DRAFFT) to compare the relative cost effectiveness of percutaneous Kirschner wire (K-wire) fixation and volar locking-plate fixation for patients with dorsally-displaced fractures of the distal radius.

The cost effectiveness analysis (cost per quality-adjusted life year; QALY) was derived from a multi-centre, two-arm, parallel group, assessor-blind, randomised controlled trial which took place in 18 trauma centres in the United Kingdom. Data from 460 patients were available for analysis, which includes both a National Health Service cost perspective including costs of surgery, implants and healthcare resource use over a 12-month period after surgery, and a societal perspective, which includes the cost of time off work and the need for additional private care.

There was only a small difference in QALYs gained for patients treated with locking-plate fixation over those treated with K-wires. At a mean additional cost of £714 (95% confidence interval 588 to 865) per patient, locking-plate fixation presented an incremental cost effectiveness ratio (ICER) of £89 322 per QALY within the first 12 months of treatment. Sensitivity analyses were undertaken to assess the ICER of locking-plate fixation compared with K-wires. These were greater than £30 000.

Compared with locking-plate fixation, K-wire fixation is a ‘cost saving’ intervention, with similar health benefits.

Cite this article: Bone Joint J 2015;97-B:1082–9.