The optimal choice of management for proximal humerus fractures (PHFs) has been increasingly discussed in the literature, and this work aimed to answer the following questions: 1) what are the incidence rates of PHF in the geriatric population in the USA; 2) what is the mortality rate after PHF in the elderly population, specifically for distinct treatment procedures; and 3) what factors influence the mortality rate? PHFs occurring between 1 January 2009 and 31 December 2019 were identified from the Medicare physician service records. Incidence rates were determined, mortality rates were calculated, and semiparametric Cox regression was applied, incorporating 23 demographic, clinical, and socioeconomic covariates, to compare the mortality risk between treatments.Aims
Methods
Indocyanine green (ICG) fluorescence angiography is an emerging technique that can provide detailed anatomical information during surgery. The purpose of this study is to determine whether ICG fluorescence angiography can be used to evaluate the blood flow of the rotator cuff tendon in the clinical setting. Twenty-six patients were evaluated from October 2016 to December 2017. The participants were categorized into three groups based on their diagnoses: the rotator cuff tear group; normal rotator cuff group; and adhesive capsulitis group. After establishing a posterior standard viewing portal, intravenous administration of ICG at 0.2 mg/kg body weight was performed, and fluorescence images were recorded. The time from injection of the drug to the beginning of enhancement of the observed area was measured. The hypovascular area in the rotator cuff was evaluated, and the ratio of the hypovascular area to the anterolateral area of the rotator cuff tendon was calculated (hypovascular area ratio).Objectives
Methods
The objective of this study was to perform a meta-analysis of all randomised controlled trials (RCTs) comparing surgical and non-surgical management of fractures of the proximal humerus, and to determine whether further analyses based on complexity of fracture, or the type of surgical intervention, produced disparate findings on patient outcomes. A systematic review of the literature was performed identifying all RCTs that compared surgical and non-surgical management of fractures of the proximal humerus. Meta-analysis of clinical outcomes was performed where possible. Subgroup analysis based on the type of fracture, and a sensitivity analysis based on the type of surgical intervention, were also performed.Objectives
Methods
The aim of this study was to compare the pain caused by the application
of a tourniquet after exsanguination of the upper limb with that
occurring after simple elevation. We used 26 healthy volunteers (52 arms), each of whom acted as
their own matched control. The primary outcome measure was the total pain experienced by
each volunteer while the tourniquet was inflated for 20 minutes.
This was calculated as the area under the pain curve for each individual
subject. Secondary outcomes were pain at each time point; the total
pain experienced during the recovery phase; the ability to tolerate the
tourniquet and the time for full recovery after deflation of the
tourniquet. Aims
Patients and Methods
We present a review of claims made to the NHS
Litigation Authority (NHSLA) by patients with conditions affecting the
shoulder and elbow, and identify areas of dissatisfaction and potential
improvement. Between 1995 and 2012, the NHSLA recorded 811 claims
related to the shoulder and elbow, 581 of which were settled. This
comprised 364 shoulder (64%), and 217 elbow (36%) claims. A total
of £18.2 million was paid out in settled claims. Overall diagnosis,
mismanagement and intra-operative nerve injury were the most common
reasons for litigation. The highest cost paid out resulted from
claims dealing with incorrect, missed or delayed diagnosis, with
just under £6 million paid out overall. Fractures and dislocations
around the shoulder and elbow were common injuries in this category.
All 11 claims following wrong-site surgery that were settled led
to successful payouts. This study highlights the diagnoses and procedures that need
to be treated with particular vigilance. Having an awareness of
the areas that lead to litigation in shoulder and elbow surgery
will help to reduce inadvertent risks to patients and prevent dissatisfaction
and possible litigation. Cite this article:
The sternoclavicular joint (SCJ) is a pivotal
articulation in the linked system of the upper limb girdle, providing
load-bearing in compression while resisting displacement in tension
or distraction at the manubrium sterni. The SCJ and acromioclavicular
joint (ACJ) both have a small surface area of contact protected
by an intra-articular fibrocartilaginous disc and are supported
by strong extrinsic and intrinsic capsular ligaments. The function
of load-sharing in the upper limb by bulky periscapular and thoracobrachial
muscles is extremely important to the longevity of both joints.
Ligamentous and capsular laxity changes with age, exposing both
joints to greater strain, which may explain the rising incidence
of arthritis in both with age. The incidence of arthritis in the
SCJ is less than that in the ACJ, suggesting that the extrinsic
ligaments of the SCJ provide greater stability than the coracoclavicular
ligaments of the ACJ. Instability of the SCJ is rare and can be difficult to distinguish
from medial clavicular physeal or metaphyseal fracture-separation:
cross-sectional imaging is often required. The distinction is important
because the treatment options and outcomes of treatment are dissimilar,
whereas the treatment and outcomes of ACJ separation and fracture
of the lateral clavicle can be similar. Proper recognition and treatment
of traumatic instability is vital as these injuries may be life-threatening.
Instability of the SCJ does not always require surgical intervention.
An accurate diagnosis is required before surgery can be considered,
and we recommend the use of the Stanmore instability triangle. Most
poor outcomes result from a failure to recognise the underlying
pathology. There is a natural reluctance for orthopaedic surgeons to operate
in this area owing to unfamiliarity with, and the close proximity
of, the related vascular structures, but the interposed sternohyoid
and sternothyroid muscles are rarely injured and provide a clear
boundary to the medial retroclavicular space, as well as an anatomical
barrier to unsafe intervention. This review presents current concepts of instability of the SCJ,
describes the relevant surgical anatomy, provides a framework for
diagnosis and management, including physiotherapy, and discusses
the technical challenges of operative intervention. Cite this article:
Lateral clavicular physeal injuries in adolescents
are frequently misinterpreted as acromioclavicular
Instability after arthroplasty of the shoulder
is difficult to correct surgically. Soft-tissue procedures and revision surgery
using unconstrained anatomical components are associated with a
high rate of failure. The purpose of this study was to determine
the results of revision of an unstable anatomical shoulder arthroplasty
to a reverse design prosthesis. Between 2004 and 2007, 33 unstable
anatomical shoulder arthroplasties were revised to a reverse design.
The mean age of the patients was 71 years (53 to 86) and their mean
follow-up was 42 months (25 to 71). The mean time to revision was
26 months (4 to 164). Pain scores improved significantly (pre-operative
visual analogue scale (VAS) of 7.2 ( Cite this article:
There have been only a few small studies of patients
with an infected shoulder replacement treated with a single-stage
exchange procedure. We retrospectively reviewed 35 patients (19 men
and 16 women) with a peri-prosthetic infection of the shoulder who
were treated in this way. A total of 26 were available for clinical
examination; three had died, two were lost to follow-up and four
patients had undergone revision surgery. The mean follow-up time was
4.7 years (1.1 to 13.25), with an infection-free survival of 94%. The organisms most commonly isolated intra-operatively were Single-stage exchange is a successful and practical treatment
for patients with peri-prosthetic infection of the shoulder. Cite this article:
Reverse total shoulder replacement (RTSR) depends
on adequate deltoid function for a successful outcome. However, the
anterior deltoid and/or axillary nerve may be damaged due to prior
procedures or injury. The purpose of this study was to determine
the compensatory muscle forces required for scapular plane elevation
following RTSR when the anterior deltoid is deficient. The soft
tissues were removed from six cadaver shoulders, except for tendon
attachments. After implantation of the RTSR, the shoulders were
mounted on a custom-made shoulder simulator to determine the mean
force in each muscle required to achieve 30° and 60° of scapular
plane elevation. Two conditions were tested: 1) Control with an
absent supraspinatus and infraspinatus; and 2) Control with anterior
deltoid deficiency. Anterior deltoid deficiency resulted in a mean
increase of 195% in subscapularis force at 30° when compared with
the control (p = 0.02). At 60°, the subscapularis force increased
a mean of 82% (p <
0.001) and the middle deltoid force increased
a mean of 26% (p = 0.04). Scapular plane elevation may still be possible following an RTSR
in the setting of anterior deltoid deficiency. When the anterior
deltoid is deficient, there is a compensatory increase in the force
required by the subscapularis and middle deltoid. Attempts to preserve
the subscapularis, if present, might maximise post-operative function.
The Motec cementless modular metal-on-metal ball-and-socket
wrist arthroplasty was implanted in 16 wrists with scaphoid nonunion
advanced collapse (SNAC; grades 3 or 4) and 14 wrists with scapholunate
advanced collapse (SLAC) in 30 patients (20 men) with severe (grades
3 or 4) post-traumatic osteoarthritis of the wrist. The mean age of
the patients was 52 years (31 to 71). All prostheses integrated
well radiologically. At a mean follow-up of 3.2 years (1.1 to 6.1)
no luxation or implant breakage occurred. Two wrists were converted
to an arthrodesis for persistent pain. Loosening occurred in one
further wrist at five years post-operatively. The remainder demonstrated close
bone–implant contact. The clinical results were good, with markedly
decreased Disabilities of the Arm Shoulder and Hand (DASH) and pain
scores, and increased movement and grip strength. No patient used
analgesics and most had returned to work. Good short-term function was achieved using this wrist arthroplasty
in a high-demand group of patients with post-traumatic osteoarthritis.
Bone loss involving articular surface is a challenging
problem faced by the orthopaedic surgeon. In the hand and wrist,
there are articular defects that are amenable to autograft reconstruction
when primary fixation is not possible. In this article, the surgical
techniques and clinical outcomes of articular reconstructions in
the hand and wrist using non-vascularised osteochondral autografts
are reviewed.
This study evaluates the position of the long
head of biceps tendon using ultrasound following simple tenotomy,
in patients with arthroscopically repaired rotator cuff tears. In total, 52 patients with a mean age of 60.7 years (45 to 75)
underwent arthroscopic repair of the rotator cuff and simple tenotomy
of the long head of biceps tendon. At two years post-operatively,
ultrasound revealed that the tendon was inside the bicipital groove
in 43 patients (82.7%) and outside in nine (17.3%); in six of these
it was lying just outside the groove and in the remaining three
(5.8%) it was in a remote position with a positive Popeye Sign.
A dynamic ultrasound scan revealed that the tenotomised tendons
had adhered to the surrounding tissues (autotenodesis).The initial
condition of the tendon influenced its final position (p <
0.0005).
The presence of a Popeye sign was statistically influenced by the
pre-operative co-existence of supraspinatus and subscapularis tears (p
<
0.0001). It appears that the natural history of the tenotomised long head
of biceps tendon is to tenodese itself inside or just outside the
bicipital groove, while its pre-operative condition and coexistent
subscapularis tears play a significant role in the occurrence of
a Popeye sign.
We systematically reviewed all the evidence published
in the English language on proximal interphalangeal joint (PIPJ)
replacement, to determine its effectiveness on the function of the
hand and the associated post-operative complications. Original studies were selected if they reported clinical outcome
with a minimum of one year’s follow-up. Quality was assessed using
the Cowley systematic review criteria modified for finger-joint
replacements. Of 319 articles identified, only five were adequately
reported according to our quality criteria; there were no randomised
controlled trials. PIPJ replacements had a substantial effect size
on hand pain of -23.2 (95% confidence interval (CI) -27.3 to -19.1)
and grip strength 1.2 (95% CI -10.7 to 13.1), and a small effect
on range of movement 0.2 (95% CI -0.4 to 0.8). A dorsal approach
was most successful. Post-operative loosening occurred in 10% (95%
CI 3 to 30) of ceramic and 12.5% (95% CI 7 to 21) of pyrocarbon
replacements. Post-operative complications occurred in 27.8% (95%
CI 20 to 37). We conclude that the effectiveness of PIPJ replacement has not
been established. Small observational case studies and short-term
follow-up, together with insufficient reporting of patient data,
functional outcomes and complications, limit the value of current
evidence. We recommend that a defined core set of patients, surgical and
outcome data for this intervention be routinely and systematically
collected within the framework of a joint registry.
There is little information about the management
of peri-prosthetic fracture of the humerus after total shoulder replacement
(TSR). This is a retrospective review of 22 patients who underwent
a revision of their original shoulder replacement for peri-prosthetic
fracture of the humerus with bone loss and/or loose components.
There were 20 women and two men with a mean age of 75 years (61
to 90) and a mean follow-up 42 months (12 to 91): 16 of these had
undergone a previous revision TSR. Of the 22 patients, 12 were treated
with a long-stemmed humeral component that bypassed the fracture.
All their fractures united after a mean of 27 weeks (13 to 94).
Eight patients underwent resection of the proximal humerus with
endoprosthetic replacement to the level of the fracture. Two patients
were managed with a clam-shell prosthesis that retained the original
components. The mean Oxford shoulder score (OSS) of the original
TSRs before peri-prosthetic fracture was 33 (14 to 48). The mean
OSS after revision for fracture was 25 (9 to 31). Kaplan-Meier survival
using re-intervention for any reason as the endpoint was 91% (95%
confidence interval (CI) 68 to 98) and 60% (95% CI 30 to 80) at
one and five years, respectively. There were two revisions for
A total of 12 epileptic patients (14 shoulders)
with recurrent seizures and anterior
Follow-up radiographs are usually used as the
reference standard for the diagnosis of suspected scaphoid fractures. However,
these are prone to errors in interpretation. We performed a meta-analysis
of 30 clinical studies on the diagnosis of suspected scaphoid fractures,
in which agreement data between any of follow-up radiographs, bone scintigraphy,
magnetic resonance (MR) imaging, or CT could be obtained, and combined
this with latent class analysis to infer the accuracy of these tests
on the diagnosis of suspected scaphoid fractures in the absence
of an established standard. The estimated sensitivity and specificity
were respectively 91.1% and 99.8% for follow-up radiographs, 97.8%
and 93.5% for bone scintigraphy, 97.7% and 99.8% for MRI, and 85.2%
and 99.5% for CT. The results were generally robust in multiple
sensitivity analyses. There was large between-study heterogeneity
for the sensitivity of follow-up radiographs and CT, and imprecision
about their sensitivity estimates. If we acknowledge the lack of a reference standard for diagnosing
suspected scaphoid fractures, MRI is the most accurate test; follow-up
radiographs and CT may be less sensitive, and bone scintigraphy
less specific.
We reviewed 101 patients with injuries of the
terminal branches of the infraclavicular brachial plexus sustained between
1997 and 2009. Four patterns of injury were identified: 1) anterior
glenohumeral
We assessed the short- to mid-term survival of
metallic press-fit radial head prostheses in patients with radial
head fractures and acute traumatic instability of the elbow. The medical records of 42 patients (16 males, 26 females) with
a mean age of 56 years (23 to 85) with acute unstable elbow injuries,
including a fracture of the radial head requiring metallic replacement
of the radial head, were reviewed retrospectively. Survival of the
prosthesis was assessed from the radiographs of 37 patients after
a mean follow-up of 50 months (12 to 107). The functional results
of 31 patients were assessed using range-of-movement, Mayo elbow
performance score (MEPS), Disabilities of the Arm, Shoulder and
Hand (DASH) score and the RAND 36-item health survey. At the most recent follow-up 25 prostheses were still well fixed,
nine had been removed because of loosening, and three remained implanted
but were loose. The mean time from implantation to loosening was
11 months (2 to 24). Radiolucent lines that developed around the
prosthesis before removal were mild in three patients, moderate
in one and severe in five. Range of movement parameters and mass
grip strength were significantly lower in the affected elbow than
in the unaffected side. The mean MEPS score was 86 (40 to 100) and
the mean DASH score was 23 (0 to 81). According to RAND-36 scores,
patients had more pain and lower physical function scores than normal population
values. Loosening of press-fit radial head prostheses is common, occurs
early, often leads to severe osteolysis of the proximal radius,
and commonly requires removal of the prosthesis.