A total of 157 hindquarter amputations were carried
out in our institution during the last 30 years. We have investigated
the reasons why this procedure is still required and the outcome.
This operation was used as treatment for 13% of all pelvic bone
sarcomas. It was curative in 140 and palliative in 17, usually to
relieve pain. There were 90 primary procedures (57%) with the remaining
67 following the failure of previous operations to control the disease
locally. The indication for amputation in primary disease was for
large tumours for which limb-salvage surgery was no longer feasible.
The peri-operative mortality was 1.3% (n = 2) and major complications
of wound healing or infection arose in 71 (45%) patients. The survival
at five years after hindquarter amputation with the intent to cure
was 45%, and at ten years 38%. Local recurrence occurred in 23 patients
(15%). Phantom pain was a significant problem, and only 20% used
their prosthesis regularly. Functional scores were a mean of 57%.
With careful patient selection the oncological results and functional outcomes
of hindquarter amputation justify its continued use. Cite this article:
In skeletally immature patients, resection of
bone tumours and reconstruction of the lower limb often results
in leg-length discrepancy. The Stanmore non-invasive extendible
endoprosthesis, which uses electromagnetic induction, allows post-operative
lengthening without anaesthesia. Between 2002 and 2009, 55 children
with a mean age of 11.4 years (5 to 16) underwent reconstruction
with this prosthesis; ten patients (18.2%) died of disseminated
disease and one child underwent amputation due to infection. We
reviewed 44 patients after a mean follow-up of 41.2 months (22 to
104). The mean Musculoskeletal Tumor Society score was 24.7 (8 to
30) and the Toronto Extremity Salvage score was 92.3% (55.2% to
99.0%). There was no local recurrence of tumour. Complications developed
in 16 patients (29.1%) and ten (18.2%) underwent revision. The mean length gained per patient was 38.6 mm (3.5 to 161.5),
requiring a mean of 11.3 extensions (1 to 40), and ten component
exchanges were performed in nine patients (16.4%) after attaining
the maximum lengthening capacity of the implant. There were 11 patients
(20%) who were skeletally mature at follow-up, ten of whom had equal
leg lengths and nine had a full range of movement of the hip and
knee. This is the largest reported series using non-invasive extendible
endoprostheses after excision of primary bone tumours in skeletally
immature patients. The technique produces a good functional outcome,
with prevention of limb-length discrepancy at skeletal maturity.
The humerus is a common site for skeletal metastases in the adult. Surgical stabilisation of such lesions is often necessary to relieve pain and restore function. These procedures are essentially palliative and should therefore provide effective relief from pain for the remainder of the patient’s life without the need for further surgical intervention. We report a retrospective analysis of 35 patients (37 nails) with symptomatic metastases in the shaft of the humerus which were treated by locked, antegrade nailing. There were 27 true fractures (73.0%) and ten painful deposits (27.0%). Relief from pain was excellent in four (11.4%), good in 29 (82.9%) and fair in two (5.7%) on discharge. Function was improved in all but one patient. One case of palsy of the radial nerve was noted. The mean postoperative survival was 7.1 months (0.2 to 45.5) which emphasises the poor prognosis in this group of patients. There were no failures of fixation and no case in which further surgery was required. Antegrade intramedullary nailing is an effective means of stabilising the humerus for the palliative treatment of metastases. It relieves pain and restores function to the upper limb with low attendant morbidity.
We report our experience of treating 17 patients with benign lesions of the proximal femur with non-vascularised, autologous fibular strut grafts, without osteosynthesis. The mean age of the patients at presentation was 16.5 years (5 to 33) and they were followed up for a mean of 2.9 years (0.4 to 19.5). Histological diagnoses included simple bone cyst, fibrous dysplasia, aneurysmal bone cysts and giant cell tumour. Local recurrence occurred in two patients (11.7%) and superficial wound infection, chronic hip pain and deep venous thrombosis occurred in three. Pathological fracture did not occur in any patient following the procedure. We conclude that non-vascularised fibular strut grafts are a safe and satisfactory method of treating benign lesions of the proximal femur.
Pathological fractures due to metastasis with destruction of the acetabulum and central dislocation of the hip present a difficult surgical challenge. We describe a series using a single technique in which a stable and long-lasting reconstruction was obtained using standard primary hip replacement implants augmented by strong, fully-threaded steel rods with cement and steel mesh, where required. Between 1997 and 2006, 19 patients with a mean age of 66 years (48 to 83) were treated using a modified Harrington technique. Acetabular destruction was graded as Harrington class II in six cases and class III in 13. Reconstruction was achieved using three 6.5 mm rods inserted through a separate incision in the iliac crest followed by augmentation with cement and a conventional cemented Charnley or Exeter primary hip replacement. There were no peri-operative deaths. At the final follow-up (mean 25 months (5 to 110)) one rod had fractured and one construct required revision. Of the 18 patients who did not require revision, 13 had died. The mean time to death was 16 months (5 to 55). The mean follow-up of the five survivors was 31 months (18 to 47). There were no cases of dislocation, deep infection or injury to a nerve, the blood vessels or the bladder.
We report the results of a prospective study of 23 patients in which interstitial laser photocoagulation (ILP) was used to treat an osteoid osteoma. ILP is a technique in which tumour tissue is destroyed by direct heating using low-power laser light energy delivered by thin (400 μm) optical fibres which are introduced percutaneously into the tumour under image guidance. Pain was evaluated before operation and at the latest follow-up using a visual analogue scale with 0 denoting no pain and 10 the worst pain imaginable. The mean follow-up was for 15 months. The results showed that the mean pain score decreased from 7.5 before operation to 0.95 at the latest follow-up. Fourteen patients had no pain and eight had minor discomfort, not requiring