Advertisement for orthosearch.org.uk
Results 1 - 50 of 1009
Results per page:
Bone & Joint 360
Vol. 13, Issue 4 | Pages 35 - 37
2 Aug 2024

The August 2024 Oncology Roundup360 looks at: What factors are associated with osteoarthritis after cementation for benign aggressive bone tumour of the knee joint: a systematic review and meta-analysis; Recycled bone grafts treated with extracorporeal irradiation or liquid nitrogen freezing after malignant tumour resection; Intercalary resection of the tibia for primary bone tumours: are vascularized fibula autografts with or without allografts a durable reconstruction?; 3D-printed modular prostheses for the reconstruction of intercalary bone defects after joint-sparing limb salvage surgery for femoral diaphyseal tumours; Factors influencing the outcome of patients with primary Ewing’s sarcoma of the sacrum; The significance of surveillance imaging in children with Ewing’s sarcoma and osteosarcoma; Resection margin and soft-tissue sarcomas of the extremities treated with limb-sparing surgery and postoperative radiotherapy.


Aims

The aim of this study was to compare the migration of the femoral component, five years postoperatively, between patients with a highly cross-linked polyethylene (HXLPE) insert and those with a conventional polyethylene (PE) insert in an uncemented Triathlon fixed insert cruciate-retaining total knee arthroplasty (TKA). Secondary aims included clinical outcomes and patient-reported outcome measures (PROMs). We have previously reported the migration and outcome of the tibial components in these patients.

Methods

A double-blinded randomized controlled trial was conducted including 96 TKAs. The migration of the femoral component was measured with radiostereometry (RSA) at three and six months and one, two, and five years postoperatively. PROMs were collected preoperatively and at all periods of follow-up.


Bone & Joint Open
Vol. 5, Issue 7 | Pages 550 - 559
5 Jul 2024
Ronaldson SJ Cook E Mitchell A Fairhurst CM Reed M Martin BC Torgerson DJ

Aims

To assess the cost-effectiveness of a two-layer compression bandage versus a standard wool and crepe bandage following total knee arthroplasty, using patient-level data from the Knee Replacement Bandage Study (KReBS).

Methods

A cost-utility analysis was undertaken alongside KReBS, a pragmatic, two-arm, open label, parallel-group, randomized controlled trial, in terms of the cost per quality-adjusted life year (QALY). Overall, 2,330 participants scheduled for total knee arthroplasty (TKA) were randomized to either a two-layer compression bandage or a standard wool and crepe bandage. Costs were estimated over a 12-month period from the UK NHS perspective, and health outcomes were reported as QALYs based on participants’ EuroQol five-dimesion five-level questionnaire responses. Multiple imputation was used to deal with missing data and sensitivity analyses included a complete case analysis and testing of costing assumptions, with a secondary analysis exploring the inclusion of productivity losses.


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 705 - 712
1 Jul 2024
Karlsson T Försth P Öhagen P Michaëlsson K Sandén B

Aims

We compared decompression alone to decompression with fusion surgery for lumbar spinal stenosis, with or without degenerative spondylolisthesis (DS). The aim was to evaluate if five-year outcomes differed between the groups. The two-year results from the same trial revealed no differences.

Methods

The Swedish Spinal Stenosis Study was a multicentre randomized controlled trial with recruitment from September 2006 to February 2012. A total of 247 patients with one- or two-level central lumbar spinal stenosis, stratified by the presence of DS, were randomized to decompression alone or decompression with fusion. The five-year Oswestry Disability Index (ODI) was the primary outcome. Secondary outcomes were the EuroQol five-dimension questionnaire (EQ-5D), visual analogue scales for back and leg pain, and patient-reported satisfaction, decreased pain, and increased walking distance. The reoperation rate was recorded.


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 516 - 521
1 Jun 2024
Al-Hourani K Haddad FS


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 522 - 524
1 Jun 2024
Kennedy JW Jones JD Meek RMD


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 623 - 630
1 Jun 2024
Perry DC Dritsaki M Achten J Appelbe D Knight R Widnall J Roland D Messahel S Costa ML Mason J

Aims

The aim of this trial was to assess the cost-effectiveness of a soft bandage and immediate discharge, compared with rigid immobilization, in children aged four to 15 years with a torus fracture of the distal radius.

Methods

A within-trial economic evaluation was conducted from the UK NHS and personal social services (PSS) perspective, as well as a broader societal point of view. Health resources and quality of life (the youth version of the EuroQol five-dimension questionnaire (EQ-5D-Y)) data were collected, as part of the Forearm Recovery in Children Evaluation (FORCE) multicentre randomized controlled trial over a six-week period, using trial case report forms and patient-completed questionnaires. Costs and health gains (quality-adjusted life years (QALYs)) were estimated for the two trial treatment groups. Regression was used to estimate the probability of the new treatment being cost-effective at a range of ‘willingness-to-pay’ thresholds, which reflect a range of costs per QALY at which governments are typically prepared to reimburse for treatment.


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 555 - 564
1 Jun 2024
Leal J Holland CT Cochrane NH Seyler TM Jiranek WA Wellman SS Bolognesi MP Ryan SP

Aims

This study aims to assess the relationship between history of pseudotumour formation secondary to metal-on-metal (MoM) implants and periprosthetic joint infection (PJI) rate, as well as establish ESR and CRP thresholds that are suggestive of infection in these patients. We hypothesized that patients with a pseudotumour were at increased risk of infection.

Methods

A total of 1,171 total hip arthroplasty (THA) patients with MoM articulations from August 2000 to March 2014 were retrospectively identified. Of those, 328 patients underwent metal artefact reduction sequence MRI and had minimum two years’ clinical follow-up, and met our inclusion criteria. Data collected included demographic details, surgical indication, laterality, implants used, history of pseudotumour, and their corresponding preoperative ESR (mm/hr) and CRP (mg/dl) levels. Multivariate logistic regression modelling was used to evaluate PJI and history of pseudotumour, and receiver operating characteristic curves were created to assess the diagnostic capabilities of ESR and CRP to determine the presence of infection in patients undergoing revision surgery.


Bone & Joint Research
Vol. 13, Issue 5 | Pages 226 - 236
9 May 2024
Jürgens-Lahnstein JH Petersen ET Rytter S Madsen F Søballe K Stilling M

Aims

Micromotion of the polyethylene (PE) inlay may contribute to backside PE wear in addition to articulate wear of total knee arthroplasty (TKA). Using radiostereometric analysis (RSA) with tantalum beads in the PE inlay, we evaluated PE micromotion and its relationship to PE wear.

Methods

A total of 23 patients with a mean age of 83 years (77 to 91), were available from a RSA study on cemented TKA with Maxim tibial components (Zimmer Biomet). PE inlay migration, PE wear, tibial component migration, and the anatomical knee axis were evaluated on weightbearing stereoradiographs. PE inlay wear was measured as the deepest penetration of the femoral component into the PE inlay.


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 25 - 31
1 May 2024
Yasunaga Y Oshima S Shoji T Adachi N Ochi M

Aims

The objective of this study was to present the outcomes of rotational acetabular osteotomy (RAO) over a 30-year period for osteoarthritis (OA) secondary to dysplasia of the hip in pre- or early-stage OA.

Methods

Between September 1987 and December 1994, we provided treatment to 47 patients (55 hips) with RAO for the management of pre- or early-stage OA due to developmental hip dysplasia. Of those, eight patients (11 hips) with pre-OA (follow-up rate 79%) and 27 patients (32 hips) with early-stage OA (follow-up rate 78%), totalling 35 patients (43 hips) (follow-up rate 78%), were available at a minimum of 28 years after surgery.


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 17 - 24
1 May 2024
Anderson LA Wylie JD Kapron C Blackburn BE Erickson JA Peters CL

Aims

Periacetabular osteotomy (PAO) is the preferred treatment for symptomatic acetabular dysplasia in adolescents and young adults. There remains a lack of consensus regarding whether intra-articular procedures such as labral repair or improvement of femoral offset should be performed at the time of PAO or addressed subsequent to PAO if symptoms warrant. The purpose was to determine the rate of subsequent hip arthroscopy (HA) in a contemporary cohort of patients, who underwent PAO in isolation without any intra-articular procedures.

Methods

From June 2012 to March 2022, 349 rectus-sparing PAOs were performed and followed for a minimum of one year (mean 6.2 years (1 to 11)). The mean age was 24 years (14 to 46) and 88.8% were female (n = 310). Patients were evaluated at final follow-up for patient-reported outcome measures (PROMs). Clinical records were reviewed for complications or subsequent surgery. Radiographs were reviewed for the following acetabular parameters: lateral centre-edge angle, anterior centre-edge angle, acetabular index, and the alpha-angle (AA). Patients were cross-referenced from the two largest hospital systems in our area to determine if subsequent HA was performed. Descriptive statistics were used to analyze risk factors for HA.


Bone & Joint Open
Vol. 5, Issue 5 | Pages 374 - 384
1 May 2024
Bensa A Sangiorgio A Deabate L Illuminati A Pompa B Filardo G

Aims

Robotic-assisted unicompartmental knee arthroplasty (R-UKA) has been proposed as an approach to improve the results of the conventional manual UKA (C-UKA). The aim of this meta-analysis was to analyze the studies comparing R-UKA and C-UKA in terms of clinical outcomes, radiological results, operating time, complications, and revisions.

Methods

The literature search was conducted on three databases (PubMed, Cochrane, and Web of Science) on 20 February 2024 according to the guidelines for Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA). Inclusion criteria were comparative studies, written in the English language, with no time limitations, on the comparison of R-UKA and C-UKA. The quality of each article was assessed using the Downs and Black Checklist for Measuring Quality.


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 359 - 364
1 Apr 2024
Özdemir E de Lange B Buckens CFM Rijnen WHC Visser J

Aims

To investigate the extent of bone development around the scaffold of custom triflange acetabular components (CTACs) over time.

Methods

We performed a single-centre historical prospective cohort study, including all patients with revision THA using the aMace CTAC between January 2017 and March 2021. A total of 18 patients (18 CTACs) were included. Models of the hemipelvis and the scaffold component of the CTACs were created by segmentation of CT scans. The CT scans were performed immediately postoperatively and at least one year after surgery. The amount of bone in contact with the scaffold was analyzed at both times, and the difference was calculated.


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 312 - 318
1 Apr 2024
Sheth NP Jones SA Sanghavi SA Manktelow A

The advent of modular porous metal augments has ushered in a new form of treatment for acetabular bone loss. The function of an augment can be seen as reducing the size of a defect or reconstituting the anterosuperior/posteroinferior columns and/or allowing supplementary fixation. Depending on the function of the augment, the surgeon can decide on the sequence of introduction of the hemispherical shell, before or after the augment. Augments should always, however, be used with cement to form a unit with the acetabular component. Given their versatility, augments also allow the use of a hemispherical shell in a position that restores the centre of rotation and biomechanics of the hip. Progressive shedding or the appearance of metal debris is a particular finding with augments and, with other radiological signs of failure, should be recognized on serial radiographs. Mid- to long-term outcomes in studies reporting the use of augments with hemispherical shells in revision total hip arthroplasty have shown rates of survival of > 90%. However, a higher risk of failure has been reported when augments have been used for patients with chronic pelvic discontinuity.

Cite this article: Bone Joint J 2024;106-B(4):312–318.


Bone & Joint 360
Vol. 13, Issue 2 | Pages 38 - 41
1 Apr 2024

The April 2024 Oncology Roundup360 looks at: Midterm outcomes of total hip arthroplasty after internal hemipelvectomy and iliofemoral arthrodesis; Intraosseous conventional central chondrosarcoma does not metastasize irrespective of grade in pelvis, scapula, and in long bone locations; Oncological and functional outcomes after resection of malignant tumours of the scapula; Reconstruction following oncological iliosacral resection – a comparison of techniques; Does primary tumour resection improve survival for patients with sarcomas of pelvic bones, sacrum, and coccyx who have metastasis at diagnosis?; Older patients with Ewing’s sarcoma: an analysis of the National Cancer Database; Diagnostic challenges in low-grade central osteosarcoma; Effect of radiotherapy on local recurrence, distant metastasis, and overall survival in 1,200 limb soft-tissue sarcoma patients: a retrospective analysis using inverse probability of treatment weighting-adjusted models.


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 336 - 343
1 Apr 2024
Haertlé M Becker N Windhagen H Ahmad SS

Aims

Periacetabular osteotomy (PAO) is widely recognized as a demanding surgical procedure for acetabular reorientation. Reports about the learning curve have primarily focused on complication rates during the initial learning phase. Therefore, our aim was to assess the PAO learning curve from an analytical perspective by determining the number of PAOs required for the duration of surgery to plateau and the accuracy to improve.

Methods

The study included 118 consecutive PAOs in 106 patients. Of these, 28 were male (23.7%) and 90 were female (76.3%). The primary endpoint was surgical time. Secondary outcome measures included radiological parameters. Cumulative summation analysis was used to determine changes in surgical duration. A multivariate linear regression model was used to identify independent factors influencing surgical time.


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 268 - 276
1 Mar 2024
Park JH Lee JH Kim DY Kim HG Kim JS Lee SM Kim SC Yoo JC

Aims

This study aimed to assess the impact of using the metal-augmented glenoid baseplate (AGB) on improving clinical and radiological outcomes, as well as reducing complications, in patients with superior glenoid wear undergoing reverse shoulder arthroplasty (RSA).

Methods

From January 2016 to June 2021, out of 235 patients who underwent primary RSA, 24 received a superior-AGB after off-axis reaming (Group A). Subsequently, we conducted propensity score matching in a 1:3 ratio, considering sex, age, follow-up duration, and glenoid wear (superior-inclination and retroversion), and selected 72 well-balanced matched patients who received a standard glenoid baseplate (STB) after eccentric reaming (Group B). Superior-inclination, retroversion, and lateral humeral offset (LHO) were measured to assess preoperative glenoid wear and postoperative correction, as well as to identify any complications. Clinical outcomes were measured at each outpatient visit before and after surgery.


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 38 - 43
1 Mar 2024
Buckner BC Urban ND Cahoy KM Lyden ER Deans CF Garvin KL

Aims

Oxidized zirconium (OxZi) and highly cross-linked polyethylene (HXLPE) were developed to minimize wear and risk of osteolysis in total hip arthroplasty (THA). However, retrieval studies have shown that scratched femoral heads may lead to runaway wear, and few reports of long-term results have been published. The purpose of this investigation is to report minimum ten-year wear rates and clinical outcomes of THA with OxZi femoral heads on HXLPE, and to compare them with a retrospective control group of cobalt chrome (CoCr) or ceramic heads on HXLPE.

Methods

From 2003 to 2006, 108 THAs were performed on 96 patients using an OxZi head with a HXLPE liner with minimum ten-year follow-up. Harris Hip Scores (HHS) were collected preoperatively and at the most recent follow-up (mean 13.3 years). Linear and volumetric liner wear was measured on radiographs of 85 hips with a minimum ten-year follow-up (mean 14.5 years). This was compared to a retrospective control group of 45 THAs using ceramic or CoCr heads from October 1999 to February 2005, with a minimum of ten years’ follow-up.


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 182 - 188
1 Feb 2024
Gallego JA Rotman D Watts AC

Aims. Acute and chronic injuries of the interosseus membrane can result in longitudinal instability of the forearm. Reconstruction of the central band of the interosseus membrane can help to restore biomechanical stability. Different methods have been used to reconstruct the central band, including tendon grafts, bone-ligament-bone grafts, and synthetic grafts. This Idea, Development, Exploration, Assessment, and Long-term (IDEAL) phase 1 study aims to review the clinical results of reconstruction using a synthetic braided cross-linked graft secured at either end with an Endobutton to restore the force balance between the bones of the forearm. Methods. An independent retrospective review was conducted of a consecutive series of 21 patients with longitudinal instability injuries treated with anatomical central band reconstruction between February 2011 and July 2019. Patients with less than 12 months’ follow-up or who were treated acutely were excluded, leaving 18 patients in total. Preoperative clinical and radiological assessments were compared with prospectively gathered data using range of motion and the abbreviated version of the Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH) functional outcome score. Results. Of the 18 patients (nine male, nine female) who met the inclusion criteria, the median follow-up was 8.5 years (interquartile range (IQR) 5.6 to 10). Their mean age was 49 years (SD 11). The mean extension improved significantly from 38° (SD 15°) to 24° (SD 9°) (p = 0.027), with a mean flexion-extension arc change from 81° (SD 27°) to 93° (SD 30°) (p = 0.172) but with no forearm rotational improvement (p = 0.233) at latest follow-up. The QuickDASH functional score improved significantly from 80 (SD 14) to 52 (SD 26) following reconstruction (p = 0.031), but generally the level of disability remains high. Radiological assessment showed no progression of proximal migration of the radius, with a stable interbutton distance and ulnar variance from immediate postoperative radiograph to the latest follow-up. Conclusion. Central band interosseus membrane reconstruction using a synthetic braided cross-linked graft can improve patient-rated arm function and range of motion, but significant functional deficits remain in patients with chronic injuries. Cite this article: Bone Joint J 2024;106-B(2):182–188


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 136 - 143
1 Feb 2024
van der Lelij TJN Marang-van de Mheen PJ Kaptein BL Koster LA Ljung P Nelissen RGHH Toksvig-Larsen S

Aims

The objective of this study was to compare the two-year migration and clinical outcomes of a new cementless hydroxyapatite (HA)-coated titanium acetabular shell with its previous version, which shared the same geometrical design but a different manufacturing process for applying the titanium surface.

Methods

Overall, 87 patients undergoing total hip arthroplasty (THA) were randomized to either a Trident II HA or Trident HA shell, each cementless with clusterholes and HA-coating. All components were used in combination with a cemented Exeter V40 femoral stem. Implant migration was measured using radiostereometric analysis (RSA), with radiographs taken within two days of surgery (baseline), and at three, 12, and 24 months postoperatively. Proximal acetabular component migration was the primary outcome measure. Clinical scores and patient-reported outcome measures (PROMs) were collected at each follow-up.


Bone & Joint Open
Vol. 5, Issue 1 | Pages 20 - 27
17 Jan 2024
Turgeon TR Vasarhelyi E Howard J Teeter M Righolt CH Gascoyne T Bohm E

Aims

A novel enhanced cement fixation (EF) tibial implant with deeper cement pockets and a more roughened bonding surface was released to market for an existing total knee arthroplasty (TKA) system.This randomized controlled trial assessed fixation of the both the EF (ATTUNE S+) and standard (Std; ATTUNE S) using radiostereometric analysis.

Methods

Overall, 50 subjects were randomized (21 EF-TKA and 23 Std-TKA in the final analysis), and had follow-up visits at six weeks, and six, 12, and 24 months to assess migration of the tibial component. Low viscosity bone cement with tobramycin was used in a standardized fashion for all subjects. Patient-reported outcome measure data was captured at preoperative and all postoperative visits.


Aims. Osteochondral lesions of the talus (OLT) are a common cause of disability and chronic ankle pain. Many operative treatment strategies have been introduced; however, they have their own disadvantages. Recently lesion repair using autologous cartilage chip has emerged therefore we investigated the efficacy of particulated autologous cartilage transplantation (PACT) in OLT. Methods. We retrospectively analyzed 32 consecutive symptomatic patients with OLT who underwent PACT with minimum one-year follow-up. Standard preoperative radiography and MRI were performed for all patients. Follow-up second-look arthroscopy or MRI was performed with patient consent approximately one-year postoperatively. Magnetic resonance Observation of Cartilage Repair Tissue (MOCART) score and International Cartilage Repair Society (ICRS) grades were used to evaluate the quality of the regenerated cartilage. Clinical outcomes were assessed using the pain visual analogue scale (VAS), Foot Function Index (FFI), and Foot Ankle Outcome Scale (FAOS). Results. All patients had ICRS grade IV cartilage lesions, except for one (ICRS grade III). The paired MOCART scores significantly improved from 42.5 (SD 1.53) to 63.5 (SD 22.60) (p = 0.025) in ten patients. Seven patients agreed to undergo second-look arthroscopy; 5 patients had grade I (normal) ICRS scores and two patients had grade II (nearly normal) ICRS scores. VAS, FFI, and all subscales of FAOS were significantly improved postoperatively (p ≤ 0.003). Conclusion. PACT significantly improved the clinical, radiological, and morphological outcomes of OLT. We consider this to be a safe and effective surgical method based on the short-term clinical results of this study. Cite this article: Bone Jt Open 2023;4(12):942–947


Bone & Joint Open
Vol. 4, Issue 12 | Pages 932 - 941
6 Dec 2023
Oe K Iida H Otsuki Y Kobayashi F Sogawa S Nakamura T Saito T

Aims

Although there are various pelvic osteotomies for acetabular dysplasia of the hip, shelf operations offer effective and minimally invasive osteotomy. Our study aimed to assess outcomes following modified Spitzy shelf acetabuloplasty.

Methods

Between November 2000 and December 2016, we retrospectively evaluated 144 consecutive hip procedures in 122 patients a minimum of five years after undergoing modified Spitzy shelf acetabuloplasty for acetabular dysplasia including osteoarthritis (OA). Our follow-up rate was 92%. The mean age at time of surgery was 37 years (13 to 58), with a mean follow-up of 11 years (5 to 21). Advanced OA (Tönnis grade ≥ 2) was present preoperatively in 16 hips (11%). The preoperative lateral centre-edge angle ranged from -28° to 25°. Survival was determined by Kaplan-Meier analysis, using conversions to total hip arthroplasty as the endpoint. Risk factors for joint space narrowing less than 2 mm were analyzed using a Cox proportional hazards model.


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1279 - 1285
1 Dec 2023
Baker JF Nadar AC Jouflas AC Smith LS Sachdeva S Yakkanti MR Malkani AL

Aims. The use of cementless total knee arthroplasty (TKA) components has increased during the past decade. The initial design of cementless metal-backed patellar components had shown high failure rates due to many factors. The aim of this study was to evaluate the clinical results of a second-generation cementless, metal-backed patellar component of a modern design. Methods. This was a retrospective review of 707 primary TKAs in 590 patients from a single institution, using a cementless, metal-backed patellar component with a mean follow-up of 6.9 years (2 to 12). A total of 409 TKAs were performed in 338 females and 298 TKAs in 252 males. The mean age of the patients was 63 years (34 to 87) and their mean BMI was 34.3 kg/m. 2. (18.8 to 64.5). The patients were chosen to undergo a cementless procedure based on age and preoperative radiological and intraoperative bone quality. Outcome was assessed using the Knee Society knee and function scores and range of motion (ROM), complications, and revisions. Results. A total of 24 TKAs (3.4%) in 24 patients failed and required revision surgery, of which five were due to patellar complications (0.71%): one for aseptic patellar loosening (0.14%) and four for polyethylene dissociation (0.57%). A total of 19 revisions (2.7%) were undertaken in 19 patients for indications which did not relate to the patella: four for aseptic tibial loosening (0.57%), one for aseptic femoral loosening (0.14%), nine for periprosthetic infection (1.3%), one for popliteus impingement (0.14%), and four for instability (0.57%). Knee Society knee and function scores, and ROM, improved significantly when comparing pre- and postoperative values. Survival of the metal-backed patellar component for all-cause failure was 97.5% (95% confidence interval 94.9% to 100%) at 12 years. Conclusion. The second-generation cementless TKA design of metal-backed patellar components showed a 97.5% survival at 12 years, with polyethylene dissociation from the metal-backing being the most common cause of patellar failure. In view of the increased use of TKA, especially in younger, more active, or obese patients, these findings are encouraging at mean follow-up of seven years. Cite this article: Bone Joint J 2023;105-B(12):1279–1285


Bone & Joint Open
Vol. 4, Issue 12 | Pages 914 - 922
1 Dec 2023
Sang W Qiu H Xu Y Pan Y Ma J Zhu L

Aims

Unicompartmental knee arthroplasty (UKA) is the preferred treatment for anterior medial knee osteoarthritis (OA) owing to the rapid postoperative recovery. However, the risk factors for UKA failure remain controversial.

Methods

The clinical data of Oxford mobile-bearing UKAs performed between 2011 and 2017 with a minimum follow-up of five years were retrospectively analyzed. Demographic, surgical, and follow-up data were collected. The Cox proportional hazards model was used to identify the risk factors that contribute to UKA failure. Kaplan-Meier survival was used to compare the effect of the prosthesis position on UKA survival.


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1303 - 1313
1 Dec 2023
Trammell AP Hao KA Hones KM Wright JO Wright TW Vasilopoulos T Schoch BS King JJ

Aims

Both anatomical and reverse total shoulder arthroplasty (aTSA and rTSA) provide functional improvements. A reported benefit of aTSA is better range of motion (ROM). However, it is not clear which procedure provides better outcomes in patients with limited foward elevation (FE). The aim of this study was to compare the outcome of aTSA and rTSA in patients with glenohumeral osteoarthritis (OA), an intact rotator cuff, and limited FE.

Methods

This was a retrospective review of a single institution’s prospectively collected shoulder arthroplasty database for TSAs undertaken between 2007 and 2020. A total of 344 aTSAs and 163 rTSAs, which were performed in patients with OA and an intact rotator cuff with a minimum follow-up of two years, were included. Using the definition of preoperative stiffness as passive FE ≤ 105°, three cohorts were matched 1:1 by age, sex, and follow-up: stiff aTSAs (85) to non-stiff aTSAs (85); stiff rTSAs (74) to non-stiff rTSAs (74); and stiff rTSAs (64) to stiff aTSAs (64). We the compared ROMs, outcome scores, and complication and revision rates.


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1271 - 1278
1 Dec 2023
Rehman Y Korsvold AM Lerdal A Aamodt A

Aims

This study compared patient-reported outcomes of three total knee arthroplasty (TKA) designs from one manufacturer: one cruciate-retaining (CR) design, and two cruciate-sacrificing designs, anterior-stabilized (AS) and posterior-stabilized (PS).

Methods

Patients scheduled for primary TKA were included in a single-centre, prospective, three-armed, blinded randomized trial (n = 216; 72 per group). After intraoperative confirmation of posterior cruciate ligament (PCL) integrity, patients were randomly allocated to receive a CR, AS, or PS design from the same TKA system. Insertion of an AS or PS design required PCL resection. The primary outcome was the mean score of all five subscales of the Knee injury and Osteoarthritis Outcome Score (KOOS) at two-year follow-up. Secondary outcomes included all KOOS subscales, Oxford Knee Score, EuroQol five-dimension health questionnaire, EuroQol visual analogue scale, range of motion (ROM), and willingness to undergo the operation again. Patient satisfaction was also assessed.


Bone & Joint Open
Vol. 4, Issue 11 | Pages 846 - 852
8 Nov 2023
Kim RG Maher AW Karunaratne S Stalley PD Boyle RA

Aims

Tenosynovial giant cell tumour (TGCT) is a rare benign tumour of the musculoskeletal system. Surgical management is fraught with challenges due to high recurrence rates. The aim of this study was to describe surgical treatment and evaluate surgical outcomes of TGCT at an Australian tertiary referral centre for musculoskeletal tumours and to identify factors affecting recurrence rates.

Methods

A prospective database of all patients with TGCT surgically managed by two orthopaedic oncology surgeons was reviewed. All cases irrespective of previous treatment were included and patients without follow-up were excluded. Pertinent tumour characteristics and surgical outcomes were collected for analysis.


Bone & Joint Open
Vol. 4, Issue 11 | Pages 839 - 845
6 Nov 2023
Callary SA Sharma DK D’Apollonio TM Campbell DG

Aims

Radiostereometric analysis (RSA) is the most accurate radiological method to measure in vivo wear of highly cross-linked polyethylene (XLPE) acetabular components. We have previously reported very low wear rates for a sequentially irradiated and annealed X3 XLPE liner (Stryker Orthopaedics, USA) when used in conjunction with a 32 mm femoral heads at ten-year follow-up. Only two studies have reported the long-term wear rate of X3 liners used in conjunction with larger heads using plain radiographs which have poor sensitivity. The aim of this study was to measure the ten-year wear of thin X3 XLPE liners against larger 36 or 40 mm articulations with RSA.

Methods

We prospectively reviewed 19 patients who underwent primary cementless THA with the XLPE acetabular liner (X3) and a 36 or 40 mm femoral head with a resultant liner thickness of at least 5.8 mm. RSA radiographs at one week, six months, and one, two, five, and ten years postoperatively and femoral head penetration within the acetabular component were measured with UmRSA software. Of the initial 19 patients, 12 were available at the ten-year time point.


The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1168 - 1176
1 Nov 2023
Yüksel Y Koster LA Kaptein BL Nelissen RGHH den Hollander P

Aims. Conflicting clinical results are reported for the ATTUNE Total Knee Arthroplasty (TKA). This randomized controlled trial (RCT) evaluated five-year follow-up results comparing cemented ATTUNE and PFC-Sigma cruciate retaining TKAs, analyzing component migration as measured by radiostereometric analysis (RSA), clinical outcomes, patient-reported outcome measures (PROMs), and radiological outcomes. Methods. A total of 74 primary TKAs were included in this single-blind RCT. RSA examinations were performed, and PROMs and clinical outcomes were collected immediate postoperatively, and at three, six, 12, 24, and 60 months’ follow-up. Radiolucent lines (RLLs) were measured in standard anteroposterior radiographs at six weeks, and 12 and 60 months postoperatively. Results. At five-year follow-up, RSA data from 61 patients were available and the mean maximum total point motion (MTPM) of the femoral components were: ATTUNE: 0.96 mm (95% confidence interval (CI) 0.79 to 1.14) and PFC-Sigma 1.37 mm (95% CI 1.18 to 1.59) (p < 0.001). The PFC-Sigma femoral component migrated more in the first postoperative year, but stabilized thereafter. MPTM of the tibial components were comparable at five-year follow-up: ATTUNE 1.12 mm (95% CI 0.95 to 1.31) and PFC-Sigma 1.25 mm (95% CI 1.07 to 1.44) (p = 0.438). RLL at the medial tibial implant-cement interface remained more prevalent for the ATTUNE at five-year follow-up compared to the PFC-Sigma (20% vs 3%). RLL did not progress over time, and varied between patients at different timepoints for both TKA systems. Clinical outcomes and PROMs improved compared with preoperative scores, and were not different between groups. Conclusion. MTPM migration at five-year follow-up of the femoral and tibial component of the ATTUNE were similar and as low as that of the PFC-Sigma. MTPM migration of both knee implants did not significantly change from one year post-surgery, indicating stable fixation. Long-term ATTUNE performance may be expected to be comparable to the clinically well-performing PFC-Sigma. We have not found evidence of increased tibial component migration as measured by RSA to support concerns about cement debonding and a higher risk of aseptic loosening with the ATTUNE TKA. Cite this article: Bone Joint J 2023;105-B(11):1168–1176


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1099 - 1107
1 Oct 2023
Henry JK Shaffrey I Wishman M Palma Munita J Zhu J Cody E Ellis S Deland J Demetracopoulos C

Aims

The Vantage Total Ankle System is a fourth-generation low-profile fixed-bearing implant that has been available since 2016. We aimed to describe our early experience with this implant.

Methods

This is a single-centre retrospective review of patients who underwent primary total ankle arthroplasty (TAA) with a Vantage implant between November 2017 and February 2020, with a minimum of two years’ follow-up. Four surgeons contributed patients. The primary outcome was reoperation and revision rate of the Vantage implant at two years. Secondary outcomes included radiological alignment, peri-implant complications, and pre- and postoperative patient-reported outcomes.


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1070 - 1077
1 Oct 2023
Png ME Costa M Nickil A Achten J Peckham N Reed MR

Aims

To compare the cost-effectiveness of high-dose, dual-antibiotic cement versus single-antibiotic cement for the treatment of displaced intracapsular hip fractures in older adults.

Methods

Using data from a multicentre randomized controlled trial (World Hip Trauma Evaluation 8 (WHiTE-8)) in the UK, a within-trial economic evaluation was conducted. Resource usage was measured over 120 days post randomization, and cost-effectiveness was reported in terms of incremental cost per quality-adjusted life year (QALY), gained from the UK NHS and personal social services (PSS) perspective in the base-case analysis. Methodological uncertainty was addressed using sensitivity analysis, while decision uncertainty was handled using confidence ellipses and cost-effectiveness acceptability curves.


Aims

Arthroscopic microfracture is a conventional form of treatment for patients with osteochondritis of the talus, involving an area of < 1.5 cm2. However, some patients have persistent pain and limitation of movement in the early postoperative period. No studies have investigated the combined treatment of microfracture and shortwave treatment in these patients. The aim of this prospective single-centre, randomized, double-blind, placebo-controlled trial was to compare the outcome in patients treated with arthroscopic microfracture combined with radial extracorporeal shockwave therapy (rESWT) and arthroscopic microfracture alone, in patients with ostechondritis of the talus.

Methods

Patients were randomly enrolled into two groups. At three weeks postoperatively, the rESWT group was given shockwave treatment, once every other day, for five treatments. In the control group the head of the device which delivered the treatment had no energy output. The two groups were evaluated before surgery and at six weeks and three, six and 12 months postoperatively. The primary outcome measure was the American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot Scale. Secondary outcome measures included a visual analogue scale (VAS) score for pain and the area of bone marrow oedema of the talus as identified on sagittal fat suppression sequence MRI scans.


Bone & Joint 360
Vol. 12, Issue 5 | Pages 30 - 34
1 Oct 2023

The October 2023 Shoulder & Elbow Roundup360 looks at: Arthroscopic capsular shift surgery in patients with atraumatic shoulder joint instability: a randomized, placebo-controlled trial; Superior capsular reconstruction partially restores native glenohumeral loads in a dynamic model; Gene expression in glenoid articular cartilage varies in acute instability, chronic instability, and osteoarthritis; Intra-articular injection versus interscalene brachial plexus block for acute-phase postoperative pain management after arthroscopic shoulder surgery; Level of pain catastrophizing rehab in subacromial impingement: secondary analyses from a pragmatic randomized controlled trial (the SExSI Trial); Anterosuperior versus deltopectoral approach for primary reverse total shoulder arthroplasty: a study of 3,902 cases from the Dutch National Arthroplasty Registry with a minimum follow-up of five years; Assessment of progression and clinical relevance of stress-shielding around press-fit radial head arthroplasty: a comparative study of two implants; A number of modifiable and non-modifiable factors increase the risk for elbow medial ulnar collateral ligament injury in baseball players: a systematic review.


Aims

Ankle fracture fixation is commonly performed by junior trainees. Simulation training using cadavers may shorten the learning curve and result in a technically superior surgical performance.

Methods

We undertook a preliminary, pragmatic, single-blinded, multicentre, randomized controlled trial of cadaveric simulation versus standard training. Primary outcome was fracture reduction on postoperative radiographs.


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 905 - 911
1 Aug 2023
Giannicola G Amura A Sessa P Prigent S Cinotti G

Aims. The aim of this study was to analyze how proximal radial neck resorption (PRNR) starts and progresses radiologically in two types of press-fit radial head arthroplasties (RHAs), and to investigate its clinical relevance. Methods. A total of 97 patients with RHA were analyzed: 56 received a bipolar RHA (Group 1) while 41 received an anatomical implant (Group 2). Radiographs were performed postoperatively and after three, six, nine, and 12 weeks, six, nine, 12, 18, and 24 months, and annually thereafter. PRNR was measured in all radiographs in the four radial neck quadrants. The Mayo Elbow Performance Score (MEPS), the abbreviated version of the Disabilities of the Arm, Shoulder, and Hand questionnaire (QuickDASH), and the patient-assessed American Shoulder and Elbow Surgeons score - Elbow (pASES-E) were used for the clinical assessment. Radiological signs of implant loosening were investigated. Results. The mean follow-up was six years (2 to 14). PRNR started after a mean of 7.5 weeks (SD 2.1) and progressed significantly during the first two years, by the end of which the bone resorption stabilized. PRNR was detected in 81% (n = 45) of patients in Group 1 and 88% (n = 36) in Group 2. The final mean PRNR was 3.0 mm (SD 2.3) in Group 1 and 3.7 mm (SD 2.5) in Group 2. The mean MEPS, QuickDASH, and pASES-E were 95.9 (SD 11.5), 4.4 (SD 9.2), and 94.8 (SD 10.9) in Group 1 and 92.2 (SD 16.2), 9.9 (SD 21.5), and 90.8 (SD 15) in Group 2, respectively. No significant differences were observed between groups in the clinical and radiological outcomes. No correlations were found between PRNR and the clinical results. Conclusion. PRNR after press-fit RHA is a common radiological finding that develops in the first 24 months before stabilizing definitively. PRNR does not affect the clinical results or implant survival in the mid term. Cite this article: Bone Joint J 2023;105-B(8):905–911


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 880 - 887
1 Aug 2023
Onodera T Momma D Matsuoka M Kondo E Suzuki K Inoue M Higano M Iwasaki N

Aims

Implantation of ultra-purified alginate (UPAL) gel is safe and effective in animal osteochondral defect models. This study aimed to examine the applicability of UPAL gel implantation to acellular therapy in humans with cartilage injury.

Methods

A total of 12 patients (12 knees) with symptomatic, post-traumatic, full-thickness cartilage lesions (1.0 to 4.0 cm2) were included in this study. UPAL gel was implanted into chondral defects after performing bone marrow stimulation technique, and assessed for up to three years postoperatively. The primary outcomes were the feasibility and safety of the procedure. The secondary outcomes were self-assessed clinical scores, arthroscopic scores, tissue biopsies, and MRI-based estimations.


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 743 - 750
1 Jul 2023
Fujii M Kawano S Ueno M Sonohata M Kitajima M Tanaka S Mawatari D Mawatari M

Aims

To clarify the mid-term results of transposition osteotomy of the acetabulum (TOA), a type of spherical periacetabular osteotomy, combined with structural allograft bone grafting for severe hip dysplasia.

Methods

We reviewed patients with severe hip dysplasia, defined as Severin IVb or V (lateral centre-edge angle (LCEA) < 0°), who underwent TOA with a structural bone allograft between 1998 and 2019. A medical chart review was conducted to extract demographic data, complications related to the osteotomy, and modified Harris Hip Score (mHHS). Radiological parameters of hip dysplasia were measured on pre- and postoperative radiographs. The cumulative probability of TOA failure (progression to Tönnis grade 3 or conversion to total hip arthroplasty) was estimated using the Kaplan–Meier product-limited method, and a multivariate Cox proportional hazard model was used to identify predictors for failure.


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 590 - 592
1 Jun 2023
Manktelow ARJ Mitchell P Haddad FS

Cite this article: Bone Joint J 2023;105-B(6):590–592.


Bone & Joint Open
Vol. 4, Issue 6 | Pages 408 - 415
1 Jun 2023
Ramkumar PN Shaikh HJF Woo JJ Haeberle HS Pang M Brooks PJ

Aims

The aims of the study were to report for a cohort aged younger than 40 years: 1) indications for HRA; 2) patient-reported outcomes in terms of the modified Harris Hip Score (HHS); 3) dislocation rate; and 4) revision rate.

Methods

This retrospective analysis identified 267 hips from 224 patients who underwent an hip resurfacing arthroplasty (HRA) from a single fellowship-trained surgeon using the direct lateral approach between 2007 and 2019. Inclusion criteria was minimum two-year follow-up, and age younger than 40 years. Patients were followed using a prospectively maintained institutional database.


Bone & Joint Open
Vol. 4, Issue 5 | Pages 306 - 314
3 May 2023
Rilby K Mohaddes M Kärrholm J

Aims

Although the Fitmore Hip Stem has been on the market for almost 15 years, it is still not well documented in randomized controlled trials. This study compares the Fitmore stem with the CementLeSs (CLS) in several different clinical and radiological aspects. The hypothesis is that there will be no difference in outcome between stems.

Methods

In total, 44 patients with bilateral hip osteoarthritis were recruited from the outpatient clinic at a single tertiary orthopaedic centre. The patients were operated with bilateral one-stage total hip arthroplasty. The most painful hip was randomized to either Fitmore or CLS femoral component; the second hip was operated with the femoral component not used on the first side. Patients were evaluated at three and six months and at one, two, and five years postoperatively with patient-reported outcome measures, radiostereometric analysis, dual-energy X-ray absorptiometry, and conventional radiography. A total of 39 patients attended the follow-up visit at two years (primary outcome) and 35 patients at five years. The primary outcome was which hip the patient considered to have the best function at two years.


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 575 - 582
1 May 2023
Kato S Demura S Yokogawa N Shimizu T Kobayashi M Yamada Y Murakami H Tsuchiya H

Aims

Patients with differentiated thyroid carcinomas (DTCs) have a favourable long-term survival. Spinal metastases (SMs) cause a decline in performance status (PS), directly affecting mortality and indirectly preventing the use of systemic therapies. Metastasectomy is indicated, if feasible, as it yields the best local tumour control. Our study aimed to examine the long-term clinical outcomes of metastasectomy for SMs of thyroid carcinomas.

Methods

We collected data on 22 patients with DTC (16 follicular and six papillary carcinomas) and one patient with medullary carcinoma who underwent complete surgical resection of SMs at our institution between July 1992 and July 2017, with a minimum postoperative follow-up of five years. The cancer-specific survival (CSS) from the first spinal metastasectomy to death or the last follow-up was determined using Kaplan-Meier analysis. Potential factors associated with survival were evaluated using the log-rank test. We analyzed the clinical parameters and outcome data, including pre- and postoperative disability (Eastern Cooperative Oncology Group PS 3), lung and non-spinal bone metastases, and history of radioiodine and kinase inhibitor therapies.


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 467 - 470
1 May 2023
McBryde CW Prakash R Haddad FS


Aims

The primary objective of this study was to compare the five-year tibial component migration and wear between highly crosslinked polyethylene (HXLPE) inserts and conventional polyethylene (PE) inserts of the uncemented Triathlon fixed insert cruciate-retaining total knee arthroplasty (TKA). Secondary objectives included clinical outcomes and patient-reported outcome measures (PROMs).

Methods

A double-blinded, randomized study was conducted including 96 TKAs. Tibial component migration and insert wear were measured with radiostereometric analysis (RSA) at three, six, 12, 24, and 60 months postoperatively. PROMS were collected preoperatively and at all follow-up timepoints.


Bone & Joint Research
Vol. 12, Issue 4 | Pages 285 - 293
17 Apr 2023
Chevalier A Vermue H Pringels L Herregodts S Duquesne K Victor J Loccufier M

Aims

The goal was to evaluate tibiofemoral knee joint kinematics during stair descent, by simulating the full stair descent motion in vitro. The knee joint kinematics were evaluated for two types of knee implants: bi-cruciate retaining and bi-cruciate stabilized. It was hypothesized that the bi-cruciate retaining implant better approximates native kinematics.

Methods

The in vitro study included 20 specimens which were tested during a full stair descent with physiological muscle forces in a dynamic knee rig. Laxity envelopes were measured by applying external loading conditions in varus/valgus and internal/external direction.


Bone & Joint 360
Vol. 12, Issue 2 | Pages 13 - 16
1 Apr 2023

The April 2023 Hip & Pelvis Roundup360 looks at: Do technical errors determine outcomes of operatively managed femoral neck fractures in younger adults?; Single-stage or two-stage revision for hip prosthetic joint infection (INFORM); Fixation better than revision in type B periprosthetic fractures of taper slip stems; Can you maximize femoral head size at the expense of liner thickness?; Plasma D-dimer for periprosthetic joint infection?; How important is in vivo oxidation?; Total hip arthroplasty for HIV patients with osteonecrosis.


Bone & Joint 360
Vol. 12, Issue 2 | Pages 28 - 31
1 Apr 2023

The April 2023 Shoulder & Elbow Roundup360 looks at: Arthroscopic Bankart repair in athletes: in it for the long run?; Functional outcomes and the Wrightington classification of elbow fracture-dislocations; Hemiarthroplasty or ORIF intra-articular distal humerus fractures in older patients; Return to sport after total shoulder arthroplasty and hemiarthroplasty; Readmissions after shoulder arthroplasty; Arthroscopic Bankart repair in the longer term; Bankart repair with(out) remplissage or the Latarjet procedure? A systematic review and meta-analysis; Regaining motion among patients with shoulder pathology: are all exercises equal?


Aims

The optimal procedure for the treatment of ossification of the posterior longitudinal ligament (OPLL) remains controversial. The aim of this study was to compare the outcome of anterior cervical ossified posterior longitudinal ligament en bloc resection (ACOE) with posterior laminectomy and fusion with bone graft and internal fixation (PTLF) for the surgical management of patients with this condition.

Methods

Between July 2017 and July 2019, 40 patients with cervical OPLL were equally randomized to undergo surgery with an ACOE or a PTLF. The clinical and radiological results were compared between the two groups.


Bone & Joint Research
Vol. 12, Issue 3 | Pages 179 - 188
7 Mar 2023
Itoh M Itou J Imai S Okazaki K Iwasaki K

Aims. Orthopaedic surgery requires grafts with sufficient mechanical strength. For this purpose, decellularized tissue is an available option that lacks the complications of autologous tissue. However, it is not widely used in orthopaedic surgeries. This study investigated clinical trials of the use of decellularized tissue grafts in orthopaedic surgery. Methods. Using the ClinicalTrials.gov (CTG) and the International Clinical Trials Registry Platform (ICTRP) databases, we comprehensively surveyed clinical trials of decellularized tissue use in orthopaedic surgeries registered before 1 September 2022. We evaluated the clinical results, tissue processing methods, and commercial availability of the identified products using academic literature databases and manufacturers’ websites. Results. We initially identified 4,402 clinical trials, 27 of which were eligible for inclusion and analysis, including nine shoulder surgery trials, eight knee surgery trials, two ankle surgery trials, two hand surgery trials, and six peripheral nerve graft trials. Nine of the trials were completed. We identified only one product that will be commercially available for use in knee surgery with significant mechanical load resistance. Peracetic acid and gamma irradiation were frequently used for sterilization. Conclusion. Despite the demand for decellularized tissue, few decellularized tissue products are currently commercially available, particularly for the knee joint. To be viable in orthopaedic surgery, decellularized tissue must exhibit biocompatibility and mechanical strength, and these requirements are challenging for the clinical application of decellularized tissue. However, the variety of available decellularized products has recently increased. Therefore, decellularized grafts may become a promising option in orthopaedic surgery. Cite this article: Bone Joint Res 2023;12(3):179–188


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 284 - 293
1 Mar 2023
Li Y Zhang X Ji B Wulamu W Yushan N Guo X Cao L

Aims

Gram-negative periprosthetic joint infection (PJI) has been poorly studied despite its rapidly increasing incidence. Treatment with one-stage revision using intra-articular (IA) infusion of antibiotics may offer a reasonable alternative with a distinct advantage of providing a means of delivering the drug in high concentrations. Carbapenems are regarded as the last line of defense against severe Gram-negative or polymicrobial infection. This study presents the results of one-stage revision using intra-articular carbapenem infusion for treating Gram-negative PJI, and analyzes the characteristics of bacteria distribution and drug sensitivity.

Methods

We retrospectively reviewed 32 patients (22 hips and 11 knees) who underwent single-stage revision combined with IA carbapenem infusion between November 2013 and March 2020. The IA and intravenous (IV) carbapenem infusions were administered for a single Gram-negative infection, and IV vancomycin combined with IA carbapenems and vancomycin was applied for polymicrobial infection including Gram-negative bacteria. The bacterial community distribution, drug sensitivity, infection control rate, functional recovery, and complications were evaluated. Reinfection or death caused by PJI was regarded as a treatment failure.