The aims were to assess whether joint-specific outcome after total knee arthroplasty (TKA) was influenced by implant design over a 12-year follow-up period, and whether patient-related factors were associated with loss to follow-up and mortality risk. Long-term follow-up of a randomized controlled trial was undertaken. A total of 212 patients were allocated a Triathlon or a Kinemax TKA. Patients were assessed preoperatively, and one, three, eight, and 12 years postoperatively using the Oxford Knee Score (OKS). Reasons for patient lost to follow-up, mortality, and revision were recorded.Aims
Methods
The October 2024 Arthroplasty Roundup360 looks at: Breaking the mould: female representation in arthroplasty surgery remains low, with elbow leading the way; Post COVID-19: where are we with the 'catch up' in England and Wales?; Prevalence and clinical impact of sarcopenia in patients undergoing total joint replacement: a systematic review and a meta-analysis; Total joint replacement and sleep: the state of the evidence.
The October 2024 Foot & Ankle Roundup360 looks at: Hemiarthroplasty for hallux rigidus; Fixed or mobile-bearing ankle arthroplasty? A meta-analysis; Bone grafting for periprosthetic bone cysts following total ankle arthroplasty; Diabetic foot ulcer after first-ray amputation; Early motion after ankle surgery: the path to faster recovery?; Are podiatrists and orthopaedic surgeons approaching zone 2 fifth metatarsal fractures in the same way?.
Aims. This study evaluates the association between consultant and hospital volume and the risk of re-revision and 90-day mortality following first-time revision of primary hip arthroplasty for aseptic loosening. Methods. We conducted a cohort study of first-time, single-stage revision hip arthroplasties (RHAs) performed for aseptic loosening and recorded in the
Aims. Our primary aim was to establish the proportion of female orthopaedic consultants who perform arthroplasty via cases submitted to the
Aims. The Oxford Shoulder Score (OSS) is a 12-item measure commonly used for the assessment of shoulder surgeries. This study explores whether computerized adaptive testing (CAT) provides a shortened, individually tailored questionnaire while maintaining test accuracy. Methods. A total of 16,238 preoperative OSS were available in the
The August 2024 Hip & Pelvis Roundup360 looks at: Understanding perceived leg length discrepancy post-total hip arthroplasty: the role of pelvic obliquity; Influence of femoral stem design on revision rates in total hip arthroplasty; Outcomes of arthroscopic labral treatment of femoroacetabular impingement in adolescents; Characteristics and quality of online searches for direct anterior versus posterior approach for total hip arthroplasty; Rapid return to braking after anterior and posterior approach total hip arthroplasty; How much protection does a collar provide?; Timing matters: reducing infection risk in total hip arthroplasty with corticosteroid injection intervals; Identifying pain recovery patterns in total hip arthroplasty using PROMIS data.
The COVID-19 pandemic has disrupted the provision of arthroplasty services in England, Wales, and Northern Ireland. This study aimed to quantify the backlog, analyze national trends, and predict time to recovery. We performed an analysis of the mandatory prospective national registry of all independent and publicly funded hip, knee, shoulder, elbow, and ankle replacements in England, Wales, and Northern Ireland between January 2019 and December 2022 inclusive, totalling 729,642 operations. The deficit was calculated per year compared to a continuation of 2019 volume. Total deficit of cases between 2020 to 2022 was expressed as a percentage of 2019 volume. Sub-analyses were performed based on procedure type, country, and unit sector.Aims
Methods
In metal-on-metal (MoM) hip arthroplasties and resurfacings, mechanically induced corrosion can lead to elevated serum metal ions, a local inflammatory response, and formation of pseudotumours, ultimately requiring revision. The size and diametral clearance of anatomical (ADM) and modular (MDM) dual-mobility polyethylene bearings match those of Birmingham hip MoM components. If the acetabular component is satisfactorily positioned, well integrated into the bone, and has no surface damage, this presents the opportunity for revision with exchange of the metal head for ADM/MDM polyethylene bearings without removal of the acetabular component. Between 2012 and 2020, across two centres, 94 patients underwent revision of Birmingham MoM hip arthroplasties or resurfacings. Mean age was 65.5 years (33 to 87). In 53 patients (56.4%), the acetabular component was retained and dual-mobility bearings were used (DM); in 41 (43.6%) the acetabulum was revised (AR). Patients underwent follow-up of minimum two-years (mean 4.6 (2.1 to 8.5) years).Aims
Methods
During total knee replacement (TKR), surgeons can choose whether or not to resurface the patella, with advantages and disadvantages of each approach. Recently, the National Institute for Health and Care Excellence (NICE) recommended always resurfacing the patella, rather than never doing so. NICE found insufficient evidence on selective resurfacing (surgeon’s decision based on intraoperative findings and symptoms) to make recommendations. If effective, selective resurfacing could result in optimal individualized patient care. This protocol describes a randomized controlled trial to evaluate the clinical and cost-effectiveness of primary TKR with always patellar resurfacing compared to selective patellar resurfacing. The PAtellar Resurfacing Trial (PART) is a patient- and assessor-blinded multicentre, pragmatic parallel two-arm randomized superiority trial of adults undergoing elective primary TKR for primary osteoarthritis at NHS hospitals in England, with an embedded internal pilot phase (ISRCTN 33276681). Participants will be randomly allocated intraoperatively on a 1:1 basis (stratified by centre and implant type (cruciate-retaining vs cruciate-sacrificing)) to always resurface or selectively resurface the patella, once the surgeon has confirmed sufficient patellar thickness for resurfacing and that constrained implants are not required. The primary analysis will compare the Oxford Knee Score (OKS) one year after surgery. Secondary outcomes include patient-reported outcome measures at three months, six months, and one year (Knee injury and Osteoarthritis Outcome Score, OKS, EuroQol five-dimension five-level questionnaire, patient satisfaction, postoperative complications, need for further surgery, resource use, and costs). Cost-effectiveness will be measured for the lifetime of the patient. Overall, 530 patients will be recruited to obtain 90% power to detect a four-point difference in OKS between the groups one year after surgery, assuming up to 40% resurfacing in the selective group.Aims
Methods
The June 2024 Shoulder & Elbow Roundup. 360. looks at: Reverse versus anatomical total shoulder replacement for osteoarthritis? A UK national picture; Acute rehabilitation following traumatic anterior shoulder dislocation (ARTISAN): pragmatic, multicentre, randomized controlled trial; acid for rotator cuff repair: a systematic review and meta-analysis of randomized controlled trials; Metal or ceramic humeral head total shoulder arthroplasty: an analysis of data from the
The June 2024 Knee Roundup360 looks at: The estimated lifetime risk of revision after primary knee arthroplasty influenced by age, sex, and indication; Should high-risk patients seek out care from high-volume surgeons?; Stability and fracture rates in medial unicondylar knee arthroplasties; Rethinking antibiotic prophylaxis for dental procedures post-arthroplasty; Evaluating DAIR: a viable alternative for acute periprosthetic joint infection; The characteristics and predictors of mortality in periprosthetic fractures around the knee; Patient health-related quality of life deteriorates significantly while waiting six to 12 months for total hip or knee arthroplasty; The importance of looking for diversity in knee implants.
The aim of this study was to describe the prevalence and patterns of neuropathic pain over one year in a cohort of patients with chronic post-surgical pain at three months following total knee arthroplasty (TKA). Between 2016 and 2019, 363 patients with troublesome pain, defined as a score of ≤ 14 on the Oxford Knee Score pain subscale, three months after TKA from eight UK NHS hospitals, were recruited into the Support and Treatment After Replacement (STAR) clinical trial. Self-reported neuropathic pain and postoperative pain was assessed at three, nine, and 15 months after surgery using the painDETECT and Douleur Neuropathique 4 (DN4) questionnaires collected by postal survey.Aims
Methods
This study compares the re-revision rate and mortality following septic and aseptic revision hip arthroplasty (rTHA) in registry data, and compares the outcomes to previously reported data. This is an observational cohort study using data from the German Arthroplasty Registry (EPRD). A total of 17,842 rTHAs were included, and the rates and cumulative incidence of hip re-revision and mortality following septic and aseptic rTHA were analyzed with seven-year follow-up. The Kaplan-Meier estimates were used to determine the re-revision rate and cumulative probability of mortality following rTHA.Aims
Methods
The Birmingham Hip Resurfacing (BHR) was introduced in 1997 to address the needs of young active patients using a historically proven large-diameter metal-on-metal (MoM) bearing. A single designer surgeon’s consecutive series of 130 patients (144 hips) was previously reported at five and ten years, reporting three and ten failures, respectively. The aim of this study was to extend the follow-up of this original cohort at 25 years. The study extends the reporting on the first consecutive 144 resurfacing procedures in 130 patients for all indications. All operations were undertaken between August 1997 and May 1998. The mean age at operation was 52.1 years (SD 9.93; 17 to 76), and included 37 female patients (28.5%). Failure was defined as revision of either component for any reason. Kaplan-Meier survival analysis was performed. Routine follow-up with serum metal ion levels, radiographs, and Oxford Hip Scores (OHSs) was undertaken.Aims
Methods