Advertisement for orthosearch.org.uk
Results 1 - 100 of 125
Results per page:
Bone & Joint Open
Vol. 5, Issue 10 | Pages 843 - 850
8 Oct 2024
Greve K Ek S Bartha E Modig K Hedström M

Aims. The primary aim of this study was to compare surgical methods (sliding hip screw (SHS) vs intramedullary nailing (IMN)) for trochanteric hip fracture in relation to death within 120 days after surgery and return to independent living. The secondary aim was to assess whether the associations between surgical method and death or ability to return to independent living varied depending on fracture subtype or other patient characteristics. Methods. A total of 27,530 individuals from the Swedish Hip Fracture Register RIKSHÖFT (SHR) aged ≥ 70 years, admitted to hospital between 1 January 2014 and 31 December 2019 with trochanteric hip fracture, were included. Within this cohort, 12,041 individuals lived independently at baseline, had follow-up information in the SHR, and were thus investigated for return to independent living. Death within 120 days after surgery was analyzed using Cox regression with SHS as reference and adjusted for age and fracture type. Return to independent living was analyzed using logistic regression adjusted for age and fracture type. Analyses were repeated after stratification by fracture type, age, and sex. Results. Overall, 2,171 patients (18%) who were operated with SHS and 2,704 patients (18%) who were operated with IMN died within 120 days after surgery. Adjusted Cox regression revealed no difference in death within 120 days for the whole group (hazard ratio 0.97 (95% CI 0.91 to 1.03)), nor after stratification by fracture type. In total, 3,714 (66%) patients who were operated with SHS and 4,147 (64%) patients who were operated with IMN had returned to independent living at follow-up. There was no significant difference in return to independent living for the whole group (odds ratio 0.95 (95% CI 0.87 to 1.03)), nor after stratification by fracture type. Conclusion. No overall difference was observed in death within 120 days or return to independent living following surgery for trochanteric hip fracture, depending on surgical method (SHS vs IMN) in this recent Swedish cohort, but there was a suggested benefit for SHS in subgroups of patients. Cite this article: Bone Jt Open 2024;5(10):843–850


Bone & Joint Open
Vol. 5, Issue 9 | Pages 766 - 767
13 Sep 2024
Parker MJ


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 849 - 857
1 Aug 2024
Hatano M Sasabuchi Y Ishikura H Watanabe H Tanaka T Tanaka S Yasunaga H

Aims

The use of multimodal non-opioid analgesia in hip fractures, specifically acetaminophen combined with non-steroidal anti-inflammatory drugs (NSAIDs), has been increasing. However, the effectiveness and safety of this approach remain unclear. This study aimed to compare postoperative outcomes among patients with hip fractures who preoperatively received either acetaminophen combined with NSAIDs, NSAIDs alone, or acetaminophen alone.

Methods

This nationwide retrospective cohort study used data from the Diagnosis Procedure Combination database. We included patients aged ≥ 18 years who underwent surgery for hip fractures and received acetaminophen combined with NSAIDs (combination group), NSAIDs alone (NSAIDs group), or acetaminophen alone (acetaminophen group) preoperatively, between April 2010 and March 2022. Primary outcomes were in-hospital mortality and complications. Secondary outcomes were opioid use postoperatively; readmission within 90 days, one year, and two years; and total hospitalization costs. We used propensity score overlap weighting models, with the acetaminophen group as the reference group.


Bone & Joint Open
Vol. 5, Issue 6 | Pages 524 - 531
24 Jun 2024
Woldeyesus TA Gjertsen J Dalen I Meling T Behzadi M Harboe K Djuv A

Aims. To investigate if preoperative CT improves detection of unstable trochanteric hip fractures. Methods. A single-centre prospective study was conducted. Patients aged 65 years or older with trochanteric hip fractures admitted to Stavanger University Hospital (Stavanger, Norway) were consecutively included from September 2020 to January 2022. Radiographs and CT images of the fractures were obtained, and surgeons made individual assessments of the fractures based on these. The assessment was conducted according to a systematic protocol including three classification systems (AO/Orthopaedic Trauma Association (OTA), Evans Jensen (EVJ), and Nakano) and questions addressing specific fracture patterns. An expert group provided a gold-standard assessment based on the CT images. Sensitivities and specificities of surgeons’ assessments were estimated and compared in regression models with correlations for the same patients. Intra- and inter-rater reliability were presented as Cohen’s kappa and Gwet’s agreement coefficient (AC1). Results. We included 120 fractures in 119 patients. Compared to radiographs, CT increased the sensitivity of detecting unstable trochanteric fractures from 63% to 70% (p = 0.028) and from 70% to 76% (p = 0.004) using AO/OTA and EVJ, respectively. Compared to radiographs alone, CT increased the sensitivity of detecting a large posterolateral trochanter major fragment or a comminuted trochanter major fragment from 63% to 76% (p = 0.002) and from 38% to 55% (p < 0.001), respectively. CT improved intra-rater reliability for stability assessment using EVJ (AC1 0.68 to 0.78; p = 0.049) and for detecting a large posterolateral trochanter major fragment (AC1 0.42 to 0.57; p = 0.031). Conclusion. A preoperative CT of trochanteric fractures increased detection of unstable fractures using the AO/OTA and EVJ classification systems. Compared to radiographs, CT improved intra-rater reliability when assessing fracture stability and detecting large posterolateral trochanter major fragments. Cite this article: Bone Jt Open 2024;5(6):524–531


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 603 - 612
1 Jun 2024
Ahmad A Egeland EH Dybvik EH Gjertsen J Lie SA Fenstad AM Matre K Furnes O

Aims

This study aimed to compare mortality in trochanteric AO/OTA A1 and A2 fractures treated with an intramedullary nail (IMN) or sliding hip screw (SHS). The primary endpoint was 30-day mortality, with secondary endpoints at 0 to 1, 2 to 7, 8 to 30, 90, and 365 days.

Methods

We analyzed data from 26,393 patients with trochanteric AO/OTA A1 and A2 fractures treated with IMNs (n = 9,095) or SHSs (n = 17,298) in the Norwegian Hip Fracture Register (January 2008 to December 2020). Exclusions were made for patients aged < 60 years, pathological fractures, pre-2008 operations, contralateral hip fractures, fractures other than trochanteric A1/A2, and treatments other than IMNs or SHSs. Kaplan-Meier and Cox regression analyses adjusted for type of fracture, age, sex, cognitive impairment, American Society of Anesthesiologists (ASA) grade, and time period were conducted, along with calculations for number needed to harm (NNH).


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 133 - 138
1 May 2024
Peuchot H Jacquet C Fabre-Aubrespy M Ferguson D Ollivier M Flecher X Argenson J

Aims

Dual-mobility acetabular components (DMCs) have improved total hip arthroplasty (THA) stability in femoral neck fractures (FNFs). In osteoarthritis, the direct anterior approach (DAA) has been promoted for improving early functional results compared with the posterolateral approach (PLA). The aim of this study was to compare these two approaches in FNF using DMC-THA.

Methods

A prospective continuous cohort study was conducted on patients undergoing operation for FNF using DMC by DAA or PLA. Functional outcome was evaluated using the Harris Hip Score (HHS) and Parker score at three months and one year. Perioperative complications were recorded, and radiological component positioning evaluated.


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 430 - 434
1 May 2024
Eardley WGP


Bone & Joint Open
Vol. 5, Issue 2 | Pages 123 - 131
12 Feb 2024
Chen B Duckworth AD Farrow L Xu YJ Clement ND

Aims

This study aimed to determine whether lateral femoral wall thickness (LWT) < 20.5 mm was associated with increased revision risk of intertrochanteric fracture (ITF) of the hip following sliding hip screw (SHS) fixation when the medial calcar was intact. Additionally, the study assessed the association between LWT and patient mortality.

Methods

This retrospective study included ITF patients aged 50 years and over treated with SHS fixation between 2019 and 2021 at a major trauma centre. Demographic information, fracture type, delirium status, American Society of Anesthesiologists grade, and length of stay were collected. LWT and tip apex distance were measured. Revision surgery and mortality were recorded at a mean follow-up of 19.5 months (1.6 to 48). Cox regression was performed to evaluate independent risk factors associated with revision surgery and mortality.


Bone & Joint 360
Vol. 13, Issue 1 | Pages 13 - 16
1 Feb 2024

The February 2024 Hip & Pelvis Roundup360 looks at: Trial of vancomycin and cefazolin as surgical prophylaxis in arthroplasty; Is preoperative posterior femoral neck tilt a risk factor for fixation failure? Cemented versus uncemented hemiarthroplasty for displaced intracapsular fractures of the hip; Periprosthetic fractures in larger hydroxyapatite-coated stems: are collared stems a better alternative for total hip arthroplasty?; Postoperative periprosthetic fracture following hip arthroplasty with a polished taper slip versus composite beam stem; Is oral tranexamic acid as good as intravenous?; Stem design and the risk of early periprosthetic femur fractures following THA in elderly patients; Does powered femoral broaching compromise patient safety in total hip arthroplasty?


Bone & Joint Open
Vol. 5, Issue 1 | Pages 37 - 45
19 Jan 2024
Alm CE Karlsten A Madsen JE Nordsletten L Brattgjerd JE Pripp AH Frihagen F Röhrl SM

Aims. Despite limited clinical scientific backing, an additional trochanteric stabilizing plate (TSP) has been advocated when treating unstable trochanteric fractures with a sliding hip screw (SHS). We aimed to explore whether the TSP would result in less post operative fracture motion, compared to SHS alone. Methods. Overall, 31 patients with AO/OTA 31-A2 trochanteric fractures were randomized to either a SHS alone or a SHS with an additional TSP. To compare postoperative fracture motion, radiostereometric analysis (RSA) was performed before and after weightbearing, and then at four, eight, 12, 26, and 52 weeks. With the “after weightbearing” images as baseline, we calculated translations and rotations, including shortening and medialization of the femoral shaft. Results. Similar migration profiles were observed in all directions during the course of healing. At one year, eight patients in the SHS group and 12 patients in the TSP group were available for analysis, finding a clinically non-relevant, and statistically non-significant, difference in total translation of 1 mm (95% confidence interval -4.7 to 2.9) in favour of the TSP group. In line with the migration data, no significant differences in clinical outcomes were found. Conclusion. The TSP did not influence the course of healing or postoperative fracture motion compared to SHS alone. Based on our results, routine use of the TSP in AO/OTA 31-A2 trochanteric fractures cannot be recommended. The TSP has been shown, in biomechanical studies, to increase stability in sliding hip screw constructs in both unstable and intermediate stable trochanteric fractures, but the clinical evidence is limited. This study showed no advantage of the TSP in unstable (AO 31-A2) fractures in elderly patients when fracture movement was evaluated with radiostereometric analysis. Cite this article: Bone Jt Open 2024;5(1):37–45


Bone & Joint 360
Vol. 12, Issue 6 | Pages 36 - 39
1 Dec 2023

The December 2023 Trauma Roundup. 360. looks at: Distal femoral arthroplasty: medical risks under the spotlight; Quads repair: tunnels or anchors?; Complex trade-offs in treating severe tibial fractures: limb salvage versus primary amputation; Middle-sized posterior malleolus fractures – to fix?; Bone transport through induced membrane: a randomized controlled trial; Displaced geriatric femoral neck fractures; Risk factors for reoperation to promote union in 1,111 distal femur fractures; New versus old – reliability of the OTA/AO classification for trochanteric hip fractures; Risk factors for fracture-related infection after ankle fracture surgery


Bone & Joint Research
Vol. 12, Issue 10 | Pages 636 - 643
10 Oct 2023
Hamilton V Sheikh S Szczepanska A Maskell N Hamilton F Reid JP Bzdek BR Murray JRD

Aims

Orthopaedic surgery uses many varied instruments with high-speed, high-impact, thermal energy and sometimes heavy instruments, all of which potentially result in aerosolization of contaminated blood, tissue, and bone, raising concerns for clinicians’ health. This study quantifies the aerosol exposure by measuring the number and size distribution of the particles reaching the lead surgeon during key orthopaedic operations.

Methods

The aerosol yield from 17 orthopaedic open surgeries (on the knee, hip, and shoulder) was recorded at the position of the lead surgeon using an Aerodynamic Particle Sizer (APS; 0.5 to 20 μm diameter particles) sampling at 1 s time resolution. Through timestamping, detected aerosol was attributed to specific procedures.


Bone & Joint 360
Vol. 12, Issue 5 | Pages 36 - 39
1 Oct 2023

The October 2023 Trauma Roundup. 360. looks at: Intramedullary nailing versus sliding hip screw in trochanteric fracture management: the INSITE randomized clinical trial; Five-year outcomes for patients with a displaced fracture of the distal tibia; Direct anterior versus anterolateral approach in hip joint hemiarthroplasty; Proximal humerus fractures: treat them all nonoperatively?; Tranexamic acid administration by prehospital personnel; Locked plating versus nailing for proximal tibia fractures: a multicentre randomized controlled trial; A retrospective review of the rate of septic knee arthritis after retrograde femoral nailing for traumatic femoral fractures at a single academic institution


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 872 - 879
1 Aug 2023
Ogawa T Onuma R Kristensen MT Yoshii T Fujiwara T Fushimi K Okawa A Jinno T

Aims

The aim of this study was to investigate the association between additional rehabilitation at the weekend, and in-hospital mortality and complications in patients with hip fracture who underwent surgery.

Methods

A retrospective cohort study was conducted in Japan using a nationwide multicentre database from April 2010 to March 2018, including 572,181 patients who had received hip fracture surgery. Propensity score matching was performed to compare patients who received additional weekend rehabilitation at the weekend in addition to rehabilitation on weekdays after the surgery (plus-weekends group), as well as those who did not receive additional rehabilitation at the weekend but did receive weekday rehabilitation (weekdays-only group). After the propensity score matching of 259,168 cases, in-hospital mortality as the primary outcome and systemic and surgical complications as the secondary outcomes were compared between the two groups.


Bone & Joint 360
Vol. 12, Issue 3 | Pages 32 - 35
1 Jun 2023

The June 2023 Trauma Roundup. 360. looks at: Aspirin or low-molecular-weight heparin for thromboprophylaxis?; Lateral plating or retrograde nailing for distal femur fractures?; Sciatic nerve palsy after acetabular fixation: what about patient position?; How reliable is the new OTA/AO classification for trochanteric hip fractures?; Young hip fractures: is a medial buttress the answer?; When is the best time to ‘flap’ an open fracture?; The mortality burden of nonoperatively managed hip fractures


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 568 - 574
1 May 2023
Kobayashi H Ito N Nakai Y Katoh H Okajima K Zhang L Tsuda Y Tanaka S

Aims

The aim of this study was to report the patterns of symptoms and insufficiency fractures in patients with tumour-induced osteomalacia (TIO) to allow the early diagnosis of this rare condition.

Methods

The study included 33 patients with TIO who were treated between January 2000 and June 2022. The causative tumour was detected in all patients. We investigated the symptoms and evaluated the radiological patterns of insufficiency fractures of the rib, spine, and limbs.


Bone & Joint 360
Vol. 12, Issue 1 | Pages 36 - 39
1 Feb 2023

The February 2023 Trauma Roundup360 looks at: Masquelet versus bone transport in infected nonunion of tibia; Hyperbaric Oxygen for Lower Limb Trauma (HOLLT): an international multicentre randomized clinical trial; Is the T-shaped acetabular fracture really a “T”?; What causes cut-out of proximal femur nail anti-rotation device in intertrochanteric fractures?; Is the common femoral artery at risk with percutaneous fragility pelvis fixation?; Anterior pelvic ring pattern predicts displacement in lateral compression fractures; Differences in age-related characteristics among elderly patients with hip fractures.


The Bone & Joint Journal
Vol. 104-B, Issue 12 | Pages 1369 - 1378
1 Dec 2022
van Rijckevorsel VAJIM de Jong L Verhofstad MHJ Roukema GR

Aims

Factors associated with high mortality rates in geriatric hip fracture patients are frequently unmodifiable. Time to surgery, however, might be a modifiable factor of interest to optimize clinical outcomes after hip fracture surgery. This study aims to determine the influence of postponement of surgery due to non-medical reasons on clinical outcomes in acute hip fracture surgery.

Methods

This observational cohort study enrolled consecutively admitted patients with a proximal femoral fracture, for which surgery was performed between 1 January 2018 and 11 January 2021 in two level II trauma teaching hospitals. Patients with medical indications to postpone surgery were excluded. A total of 1,803 patients were included, of whom 1,428 had surgery < 24 hours and 375 had surgery ≥ 24 hours after admission.


Bone & Joint Open
Vol. 3, Issue 10 | Pages 741 - 745
1 Oct 2022
Baldock TE Dixon JR Koubaesh C Johansen A Eardley WGP

Aims. Patients with A1 and A2 trochanteric hip fractures represent a substantial proportion of trauma caseload, and national guidelines recommend that sliding hip screws (SHS) should be used for these injuries. Despite this, intramedullary nails (IMNs) are routinely implanted in many hospitals, at extra cost and with unproven patient outcome benefit. We have used data from the National Hip Fracture Database (NHFD) to examine the use of SHS and IMN for A1 and A2 hip fractures at a national level, and to define the cost implications of management decisions that run counter to national guidelines. Methods. We used the NHFD to identify all operations for fixation of trochanteric fractures in England and Wales between 1 January 2021 and 31 December 2021. A uniform price band from each of three hip fracture implant manufacturers was used to set cost implications alongside variation in implant use. Results. We identified 18,156 A1 and A2 trochanteric hip fractures in 162 centres. Of these, 13,483 (74.3%) underwent SHS fixation, 2,352 (13.0%) were managed with short IMN, and 2,321 (12.8%) were managed with long IMN. Total cost of IMN added up to £1.89 million in 2021, and the clinical justification for this is unclear since rates of IMN use varied from 0% to 97% in different centres. Conclusion. Most trochanteric hip fractures are managed with SHS, in keeping with national guidelines. There is considerable variance between hospitals for implant choice, despite the lack of evidence for clinical benefit and cost-effectiveness of more expensive nailing systems. This suggests either a lack of awareness of national guidelines or a choice not to follow them. We encourage provider units to reassess their practice if outwith the national norm. Funding bodies should examine implant use closely in this population to prevent resource waste at a time of considerable health austerity. Cite this article: Bone Jt Open 2022;3(10):741–745


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 884 - 893
1 Jul 2022
Kjærvik C Gjertsen J Stensland E Saltyte-Benth J Soereide O

Aims

This study aimed to identify risk factors (patient, healthcare system, and socioeconomic) for mortality after hip fractures and estimate their relative importance. Further, we aimed to elucidate mortality and survival patterns following fractures and the duration of excess mortality.

Methods

Data on 37,394 hip fractures in the Norwegian Hip Fracture Register from January 2014 to December 2018 were linked to data from the Norwegian Patient Registry, Statistics Norway, and characteristics of acute care hospitals. Cox regression analysis was performed to estimate risk factors associated with mortality. The Wald statistic was used to estimate and illustrate relative importance of risk factors, which were categorized in modifiable (healthcare-related) and non-modifiable (patient-related and socioeconomic). We calculated standardized mortality ratios (SMRs) comparing deaths among hip fracture patients to expected deaths in a standardized reference population.


Bone & Joint 360
Vol. 11, Issue 3 | Pages 46 - 47
1 Jun 2022
Das A


Bone & Joint 360
Vol. 11, Issue 2 | Pages 37 - 41
1 Apr 2022


Bone & Joint Research
Vol. 11, Issue 2 | Pages 102 - 111
1 Feb 2022
Jung C Cha Y Yoon HS Park CH Yoo J Kim J Jeon Y

Aims

In this study, we aimed to explore surgical variations in the Femoral Neck System (FNS) used for stable fixation of Pauwels type III femoral neck fractures.

Methods

Finite element models were established with surgical variations in the distance between the implant tip and subchondral bone, the gap between the plate and lateral femoral cortex, and inferior implant positioning. The models were subjected to physiological load.


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 274 - 282
1 Feb 2022
Grønhaug KML Dybvik E Matre K Östman B Gjertsen J

Aims. The aim of this study was to investigate if there are differences in outcome between sliding hip screws (SHSs) and intramedullary nails (IMNs) with regard to fracture stability. Methods. We assessed data from 17,341 patients with trochanteric or subtrochanteric fractures treated with SHS or IMN in the Norwegian Hip Fracture Register from 2013 to 2019. Primary outcome measures were reoperations for stable fractures (AO Foundation/Orthopaedic Trauma Association (AO/OTA) type A1) and unstable fractures (AO/OTA type A2, A3, and subtrochanteric fractures). Secondary outcome measures were reoperations for A2, A3, and subtrochanteric fractures individually, one-year mortality, quality of life (EuroQol five-dimension three-level index score), pain (visual analogue scale (VAS)), and satisfaction (VAS) for stable and unstable fractures. Hazard rate ratios (HRRs) for reoperation were calculated using Cox regression analysis with adjustments for age, sex, and American Society of Anesthesiologists score. Results. Reoperation rate was lower after surgery with IMN for unstable fractures one year (HRR 0.82, 95% confidence interval (CI) 0.70 to 0.97; p = 0.022) and three years postoperatively (HRR 0.86, 95% CI 0.74 to 0.99; p = 0.036), compared with SHS. For individual fracture types, no clinically significant differences were found. Lower one-year mortality was found for IMN compared with SHS for stable fractures (HRR 0.87; 95% CI 0.78 to 0.96; p = 0.007), and unstable fractures (HRR 0.91, 95% CI 0.84 to 0.98; p = 0.014). Conclusion. This national register-based study indicates a lower reoperation rate for IMN than SHS for unstable trochanteric and subtrochanteric fractures, but not for stable fractures or individual fracture types. The choice of implant may not be decisive to the outcome of treatment for stable trochanteric fractures in terms of reoperation rate. One-year mortality rate for unstable and stable fractures was lower in patients treated with IMN. Cite this article: Bone Joint J 2022;104-B(2):274–282


Bone & Joint Open
Vol. 2, Issue 12 | Pages 1017 - 1026
1 Dec 2021
Sadiq S Lipski C Hanif U Arshad F Chaudary M Chaudhry F

Aims

This study assessed the impact of COVID-19 on hip and distal femur fracture patient outcomes across three successive UK lockdown periods over one year.

Methods

A single-centre retrospective cohort study was performed at an acute NHS Trust. Hip and distal femur fracture patients admitted within the first month from each of the three starting dates of each national lockdown were included and compared to a control group in March 2019. Data were collected as per the best practice tariff outcomes including additional outcomes as required. Data collection included COVID-19 status, time to theatre, 30-day mortality, presence of acute kidney injury (AKI) and pneumonia, and do not attempt cardiopulmonary resuscitation (DNACPR) status. Data were analyzed using an independent-samples t-test or chi-squared test with Fisher’s exact test where applicable. A p-value of < 0.05 was considered statistically significant.


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 3 - 8
1 Jul 2021
Roberts HJ Barry J Nguyen K Vail T Kandemir U Rogers S Ward D

Aims

While interdisciplinary protocols and expedited surgical treatment improve the management of hip fractures in the elderly, the impact of such interventions on patients specifically undergoing arthroplasty for a femoral neck fracture is not clear. We sought to evaluate the efficacy of an interdisciplinary protocol for the management of patients with a femoral neck fracture who are treated with an arthroplasty.

Methods

In 2017, our institution introduced a standardized interdisciplinary hip fracture protocol. We retrospectively reviewed adult patients who underwent hemiarthroplasty (HA) or total hip arthroplasty (THA) for femoral neck fracture between July 2012 and March 2020, and compared patient characteristics and outcomes between those treated before and after the introduction of the protocol.


Bone & Joint Open
Vol. 2, Issue 6 | Pages 365 - 370
1 Jun 2021
Kolodychuk N Su E Alexiades MM Ren R Ojard C Waddell BS

Aims

Traditionally, acetabular component insertion during total hip arthroplasty (THA) is visually assisted in the posterior approach and fluoroscopically assisted in the anterior approach. The present study examined the accuracy of a new surgeon during anterior (NSA) and posterior (NSP) THA using robotic arm-assisted technology compared to two experienced surgeons using traditional methods.

Methods

Prospectively collected data was reviewed for 120 patients at two institutions. Data were collected on the first 30 anterior approach and the first 30 posterior approach surgeries performed by a newly graduated arthroplasty surgeon (all using robotic arm-assisted technology) and was compared to standard THA by an experienced anterior (SSA) and posterior surgeon (SSP). Acetabular component inclination, version, and leg length were calculated postoperatively and differences calculated based on postoperative film measurement.


Bone & Joint 360
Vol. 10, Issue 2 | Pages 43 - 47
1 Apr 2021


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 775 - 781
1 Apr 2021
Mellema JJ Janssen S Schouten T Haverkamp D van den Bekerom MPJ Ring D Doornberg JN

Aims. This study evaluated variation in the surgical treatment of stable (A1) and unstable (A2) trochanteric hip fractures among an international group of orthopaedic surgeons, and determined the influence of patient, fracture, and surgeon characteristics on choice of implant (intramedullary nailing (IMN) versus sliding hip screw (SHS)). Methods. A total of 128 orthopaedic surgeons in the Science of Variation Group evaluated radiographs of 30 patients with Type A1 and A2 trochanteric hip fractures and indicated their preferred treatment: IMN or SHS. The management of Type A3 (reverse obliquity) trochanteric fractures was not evaluated. Agreement between surgeons was calculated using multirater kappa. Multivariate logistic regression models were used to assess whether patient, fracture, and surgeon characteristics were independently associated with choice of implant. Results. The overall agreement between surgeons on implant choice was fair (kappa = 0.27 (95% confidence interval (CI) 0.25 to 0.28)). Factors associated with preference for IMN included USA compared to Europe or the UK (Europe odds ratio (OR) 0.56 (95% CI 0.47 to 0.67); UK OR 0.16 (95% CI 0.12 to 0.22); p < 0.001); exposure to IMN only during training compared to surgeons that were exposed to both (only IMN during training OR 2.6 (95% CI 2.0 to 3.4); p < 0.001); and A2 compared to A1 fractures (Type A2 OR 10 (95% CI 8.4 to 12); p < 0.001). Conclusion. In an international cohort of orthopaedic surgeons, there was a large variation in implant preference for patients with A1 and A2 trochanteric fractures. This is due to surgeon bias (country of practice and aspects of training). The observation that surgeons favoured the more expensive implant (IMN) in the absence of convincing evidence of its superiority suggests that surgeon de-biasing strategies may be a useful focus for optimizing patient outcomes and promoting value-based healthcare. Cite this article: Bone Joint J 2021;103-B(4):775–781


Aims. Surgical treatment of hip fracture is challenging; the bone is porotic and fixation failure can be catastrophic. Novel implants are available which may yield superior clinical outcomes. This study compared the clinical effectiveness of the novel X-Bolt Hip System (XHS) with the sliding hip screw (SHS) for the treatment of fragility hip fractures. Methods. We conducted a multicentre, superiority, randomized controlled trial. Patients aged 60 years and older with a trochanteric hip fracture were recruited in ten acute UK NHS hospitals. Participants were randomly allocated to fixation of their fracture with XHS or SHS. A total of 1,128 participants were randomized with 564 participants allocated to each group. Participants and outcome assessors were blind to treatment allocation. The primary outcome was the EuroQol five-dimension five-level health status (EQ-5D-5L) utility at four months. The minimum clinically important difference in utility was pre-specified at 0.075. Secondary outcomes were EQ-5D-5L utility at 12 months, mortality, residential status, mobility, revision surgery, and radiological measures. Results. Overall, 437 and 443 participants were analyzed in the primary intention-to-treat analysis in XHS and SHS treatment groups respectively. There was a mean difference of 0.029 in adjusted utility index in favour of XHS with no evidence of a difference between treatment groups (95% confidence interval -0.013 to 0.070; p = 0.175). There was no evidence of any differences between treatment groups in any of the secondary outcomes. The pattern and overall risk of adverse events associated with both treatments was similar. Conclusion. Any difference in four-month health-related quality of life between the XHS and SHS is small and not clinically important. There was no evidence of a difference in the safety profile of the two treatments; both were associated with lower risks of revision surgery than previously reported. Cite this article: Bone Joint J 2021;103-B(2):256–263


Bone & Joint 360
Vol. 9, Issue 6 | Pages 15 - 18
1 Dec 2020


Bone & Joint Open
Vol. 1, Issue 10 | Pages 644 - 653
14 Oct 2020
Kjærvik C Stensland E Byhring HS Gjertsen J Dybvik E Søreide O

Aims. The aim of this study was to describe variation in hip fracture treatment in Norway expressed as adherence to international and national evidence-based treatment guidelines, to study factors influencing deviation from guidelines, and to analyze consequences of non-adherence. Methods. International and national guidelines were identified and treatment recommendations extracted. All 43 hospitals routinely treating hip fractures in Norway were characterized. From the Norwegian Hip Fracture Register (NHFR), hip fracture patients aged > 65 years and operated in the period January 2014 to December 2018 for fractures with conclusive treatment guidelines were included (n = 29,613: femoral neck fractures (n = 21,325), stable trochanteric fractures (n = 5,546), inter- and subtrochanteric fractures (n = 2,742)). Adherence to treatment recommendations and a composite indicator of best practice were analyzed. Patient survival and reoperations were evaluated for each recommendation. Results. Median age of the patients was 84 (IQR 77 to 89) years and 69% (20,427/29,613) were women. Overall, 79% (23,390/29,613) were treated within 48 hours, and 80% (23,635/29,613) by a surgeon with more than three years’ experience. Adherence to guidelines varied substantially but was markedly better in 2018 than in 2014. Having a dedicated hip fracture unit (OR 1.06, 95%CI 1.01 to 1.11) and a hospital hip fracture programme (OR 1.16, 95% CI 1.06 to 1.27) increased the probability of treatment according to best practice. Surgery after 48 hours increased one-year mortality significantly (OR 1.13, 95% CI 1.05 to 1.22; p = 0.001). Alternative treatment to arthroplasty for displaced femoral neck fractures (FNFs) increased mortality after 30 days (OR 1.29, 95% CI 1.03 to 1.62)) and one year (OR 1.45, 95% CI 1.22 to 1.72), and also increased the number of reoperations (OR 4.61, 95% CI 3.73 to 5.71). An uncemented stem increased the risk of reoperation significantly (OR 1.23, 95% CI 1.02 to 1.48; p = 0.030). Conclusion. Our study demonstrates a substantial variation between hospitals in adherence to evidence-based guidelines for treatment of hip fractures in Norway. Non-adherence can be ascribed to in-hospital factors. Poor adherence has significant negative consequences for patients in the form of increased mortality rates at 30 and 365 days post-treatment and in reoperation rates. Cite this article: Bone Joint Open 2020;1-10:644–653


Bone & Joint Research
Vol. 9, Issue 8 | Pages 468 - 476
1 Aug 2020
Parsons NR Costa ML Achten J Griffin XL

Aims. To assess the variation in pre-fracture quality of life (QoL) within the UK hip fracture population, and quantify the nature and strength of associations between QoL and other routinely collected patient characteristics and treatment choices. Methods. The World Hip Trauma Evaluation (WHiTE) study, an observational cohort study of UK hip fracture patients, collects a range of routine data and a health-related QoL score (EuroQol five-dimension questionnaire (EQ-5D)). Pre-fracture QoL data are summarized and statistical models fitted to understand associations between QoL, patient characteristics, fracture types, and operations. Results. Fitting a multiple linear regression model indicated that 36.5% of the variance in pre-fracture EQ-5D scores was explained by routinely collected patient characteristics: sex (0.14%), age (0.17%), American Society of Anesthesiologists (ASA) score (0.73%), Abbreviated Mental Test Score (AMTS; 1.3%), pre-fracture mobility (11.2%), and EQ-5D respondent (participant, relative, or carer; 23.0%). There was considerable variation in pre-fracture EQ-5D scores between operations within fracture types. Participants with trochanteric fractures reported statistically significant but not clinically relevant lower pre-fracture QoL than those with intracapsular fractures. Participants with intracapsular fractures treated with internal fixation or total hip arthroplasty (THA) reported better QoL than those treated with hemiarthroplasty with the overall fittest group receiving THA. Conclusion. Pre-fracture QoL varies considerably between hip fracture patients; it is generally higher in younger than older patients, patients with better mobility, and those patients who live more independently. Pre-fracture QoL is significantly associated with a range of patient characteristics (e.g. age, mobility, residency). These data explain ~35% of the variation in QoL. Cite this article: Bone Joint Res 2020;9(8):468–476


The Bone & Joint Journal
Vol. 102-B, Issue 7 Supple B | Pages 57 - 61
1 Jul 2020
Woolson ST

Aims

To establish whether there was a consensus among the members of the Hip Society (HS) on the role of direct anterior approach (DAA) contemporary primary total hip arthroplasty (THA).

Methods

An online survey was sent to all 112 active and senior members of the HS, to which 71 members responded. The survey was constructed to determine whether they believed that evidence-based medicine proves, in modern clinical practice, that the DAA has significant benefits compared to risks when contrasted with other approaches. In addition, they were asked if they currently used the DAA.


Bone & Joint 360
Vol. 9, Issue 3 | Pages 31 - 34
1 Jun 2020


The Bone & Joint Journal
Vol. 102-B, Issue 3 | Pages 394 - 399
1 Mar 2020
Parker MJ Cawley S

Aims. A lack of supporting clinical studies have been published to determine the ideal length of intramedullary nail in fixation of trochanteric fractures of the hip. Nevertheless, there has been a trend to use shorter intramedullary nails for the internal fixation of trochanteric hip fractures. Our aim was to determine if the length of nail affected the outcome. Methods. We randomized 229 patients with a trochanteric hip fracture between two implants: a ‘standard’ nail of 220 mm and a shorter nail of 175 mm, which had decreased proximal angulation (4° vs 7°) and a reduced diameter at the level of the lesser trochanter. Patients were followed up for one year by a nurse blinded to the type of implant used to determine if there were differences in mobility and pain with two nail designs. Pain was assessed on a scale of 1 (none) to 8 (severe and constant) and mobility on a scale of 1 (full mobility) to 9 (immobile). Results. The shorter nail did not require any reaming of the femur and was quicker to insert (mean difference 5.1 minutes; p < 0.001, 95% confidence interval (CI) of the difference 3.16 to 7.04). Those treated by the shorter nail were less mobile (mean difference in reduction in mobility score at one year 0.80; p = 0.007, 95% CI 1.38 to 0.22). In addition, there was a trend toward greater residual pain for those treated with the shorter nail, although this was not statistically significant (mean difference in pain score at one year 0.24; p = 0.064, 95% CI -0.01 to 0.49). Conclusion. These results suggest that the increasing use of this very short intramedullary nail with its design modification may not be appropriate. Cite this article: Bone Joint J 2020;102-B(3):394–399


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 191 - 197
1 Feb 2020
Gabor JA Padilla JA Feng JE Schnaser E Lutes WB Park KJ Incavo S Vigdorchik J Schwarzkopf R

Aims

Although good clinical outcomes have been reported for monolithic tapered, fluted, titanium stems (TFTS), early results showed high rates of subsidence. Advances in stem design may mitigate these concerns. This study reports on the use of a current monolithic TFTS for a variety of indications.

Methods

A multi-institutional retrospective study of all consecutive total hip arthroplasty (THA) and revision total hip arthroplasty (rTHA) patients who received the monolithic TFTS was conducted. Surgery was performed by eight fellowship-trained arthroplasty surgeons at four institutions. A total of 157 hips in 153 patients at a mean follow-up of 11.6 months (SD7.8) were included. Mean patient age at the time of surgery was 67.4 years (SD 13.3) and mean body mass index (BMI) was 28.9 kg/m2 (SD 6.5). Outcomes included intraoperative complications, one-year all-cause re-revisions, and subsidence at postoperative time intervals (two weeks, six weeks, six months, nine months, and one year).


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 82 - 89
1 Jan 2020
Coenders MJ Mathijssen NMC Vehmeijer SBW

Aims

The aim of this study was to report our experience at 3.5 years with outpatient total hip arthroplasty (THA).

Methods

In this prospective cohort study, we included all patients who were planned to receive primary THA through the anterior approach between 1 April 2014 and 1 October 2017. Patient-related data and surgical information were recorded. Patient reported outcome measures (PROMs) related to the hip and an anchor question were taken preoperatively, at six weeks, three months, and one year after surgery. All complications, readmissions, and reoperations were registered.


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 11 - 16
1 Jan 2020
Parker MJ Cawley S

Aims

Debate continues about whether it is better to use a cemented or uncemented hemiarthroplasty to treat a displaced intracapsular fracture of the hip. The aim of this study was to attempt to resolve this issue for contemporary prostheses.

Methods

A total of 400 patients with a displaced intracapsular fracture of the hip were randomized to receive either a cemented polished tapered stem hemiarthroplasty or an uncemented Furlong hydroxyapatite-coated hemiarthroplasty. Follow-up was conducted by a nurse blinded to the implant at set intervals for up to one year from surgery.


Bone & Joint 360
Vol. 8, Issue 6 | Pages 12 - 15
1 Dec 2019


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1292 - 1299
1 Oct 2019
Masters J Metcalfe D Parsons NR Achten J Griffin XL Costa ML

Aims

This study explores data quality in operation type and fracture classification recorded as part of a large research study and a national audit with an independent review.

Patients and Methods

At 17 centres, an expert surgeon reviewed a randomly selected subset of cases from their centre with regard to fracture classification using the AO system and type of operation performed. Agreement for these variables was then compared with the data collected during conduct of the World Hip Trauma Evaluation (WHiTE) cohort study. Both types of surgery and fracture classification were collapsed to identify the level of detail of reporting that achieved meaningful agreement. In the National Hip Fracture Database (NHFD), the types of operation and fracture classification were explored to identify the proportion of “highly improbable” combinations.


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1199 - 1208
1 Oct 2019
Lamb JN Matharu GS Redmond A Judge A West RM Pandit HG

Aims. We compared implant and patient survival following intraoperative periprosthetic femoral fractures (IOPFFs) during primary total hip arthroplasty (THA) with matched controls. Patients and Methods. This retrospective cohort study compared 4831 hips with IOPFF and 48 154 propensity score matched primary THAs without IOPFF implanted between 2004 and 2016, which had been recorded on a national joint registry. Implant and patient survival rates were compared between groups using Cox regression. Results. Ten-year stem survival was worse in the IOPFF group (p < 0.001). Risk of revision for aseptic loosening increased 7.2-fold following shaft fracture and almost 2.8-fold after trochanteric fracture (p < 0.001). Risk of periprosthetic fracture of the femur revision increased 4.3-fold following calcar-crack and 3.6-fold after trochanteric fracture (p < 0.01). Risk of instability revision was 3.6-fold after trochanteric fracture and 2.4-fold after calcar crack (p < 0.001). Risk of 90-day mortality following IOPFF without revision was 1.7-fold and 4.0-fold after IOPFF with early revision surgery versus uncomplicated THA (p < 0.001). Conclusion. IOPFF increases risk of stem revision and mortality up to ten years following surgery. The risk of revision depends on IOPFF subtype and mortality risk increases with subsequent revision surgery. Surgeons should carefully diagnose and treat IOPFF to minimize fracture progression and implant failure. Cite this article: Bone Joint J 2019;101-B:1199–1208


Bone & Joint Research
Vol. 8, Issue 10 | Pages 502 - 508
1 Oct 2019
Mao W Ni H Li L He Y Chen X Tang H Dong Y

Objectives. Different criteria for assessing the reduction quality of trochanteric fractures have been reported. The Baumgaertner reduction quality criteria (BRQC) are relatively common and the Chang reduction quality criteria (CRQC) are relatively new. The objectives of the current study were to compare the reliability of the BRQC and CRQC in predicting mechanical complications and to investigate the clinical implications of the CRQC. Methods. A total of 168 patients were assessed in a retrospective observational study. Clinical information including age, sex, fracture side, American Society of Anesthesiologists (ASA) classification, tip-apex distance (TAD), fracture classification, reduction quality, blade position, BRQC, CRQC, bone quality, and the occurrence of mechanical complications were used in the statistical analysis. Results. A total of 127 patients were included in the full analysis, and mechanical complications were observed in 26 patients. The TAD, blade position, BRQC and CRQC were significantly associated with mechanical complications in the univariate analysis. Only the TAD (p = 0.025) and the CRQC (p < 0.001) showed significant results in the multivariate analysis. In the comparison of the receiver operating characteristic curves, the CRQC also performed better than the BRQC. Conclusion. The CRQC are reliable in predicting mechanical complications and are more reliable than the BRQC. Future studies could use the CRQC to assess fracture reduction quality. Intraoperatively, the surgeon should refer to the CRQC to achieve good reduction in trochanteric fractures. Cite this article: Bone Joint Res 2019;8:502–508


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1093 - 1099
1 Sep 2019
Bradley KE Ryan SP Penrose CT Grant SA Wellman SS Attarian DE Green CL Risoli T Bolognesi MP

Aims

Antifibrinolytic agents, including tranexamic acid (TXA) and epsilon-aminocaproic acid (EACA), have been shown to be safe and effective for decreasing perioperative blood loss and transfusion following total hip arthroplasty (THA) and total knee arthroplasty (TKA). However, there are few prospective studies that directly compare these agents. The purpose of this study was to compare the benefits of intraoperative intravenous TXA with EACA.

Patients and Methods

A total of 235 patients (90 THA and 145 TKA) were enrolled in this prospective, randomized controlled trial at a single tertiary-care referral centre. In the THA cohort, 53.3% of the patients were female with a median age of 59.8 years (interquartile range (IQR) 53.3 to 68.1). In the TKA cohort, 63.4% of the patients were female with a median age of 65.1 years (IQR 59.4 to 69.5). Patients received either TXA (n = 119) or EACA (n = 116) in two doses intraoperatively. The primary outcome measures included change in haemoglobin level and blood volume, postoperative drainage, and rate of transfusion. Secondary outcome measures included postoperative complications, cost, and length of stay (LOS).


Bone & Joint Research
Vol. 8, Issue 7 | Pages 313 - 322
1 Jul 2019
Law GW Wong YR Yew AK Choh ACT Koh JSB Howe TS

Objectives

The paradoxical migration of the femoral neck element (FNE) superomedially against gravity, with respect to the intramedullary component of the cephalomedullary device, is a poorly understood phenomenon increasingly seen in the management of pertrochanteric hip fractures with the intramedullary nail. The aim of this study was to investigate the role of bidirectional loading on the medial migration phenomenon, based on unique wear patterns seen on scanning electron microscopy of retrieved implants suggestive of FNE toggling.

Methods

A total of 18 synthetic femurs (Sawbones, Vashon Island, Washington) with comminuted pertrochanteric fractures were divided into three groups (n = 6 per group). Fracture fixation was performed using the Proximal Femoral Nail Antirotation (PFNA) implant (Synthes, Oberdorf, Switzerland; n = 6). Group 1 was subjected to unidirectional compression loading (600 N), with an elastomer (70A durometer) replacing loose fracture fragments to simulate surrounding soft-tissue tensioning. Group 2 was subjected to bidirectional loading (600 N compression loading, 120 N tensile loading), also with the elastomer replacing loose fracture fragments. Group 3 was subjected to bidirectional loading (600 N compression loading, 120 N tensile loading) without the elastomer. All constructs were tested at 2 Hz for 5000 cycles or until cut-out occurred. The medial migration distance (MMD) was recorded at the end of the testing cycles.


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 793 - 799
1 Jul 2019
Ugland TO Haugeberg G Svenningsen S Ugland SH Berg ØH Pripp AH Nordsletten L

Aims

The aim of this randomized trial was to compare the functional outcome of two different surgical approaches to the hip in patients with a femoral neck fracture treated with a hemiarthroplasty.

Patients and Methods

A total of 150 patients who were treated between February 2014 and July 2017 were included. Patients were allocated to undergo hemiarthroplasty using either an anterolateral or a direct lateral approach, and were followed for 12 months. The mean age of the patients was 81 years (69 to 90), and 109 were women (73%). Functional outcome measures, assessed by a physiotherapist blinded to allocation, and patient-reported outcome measures (PROMs) were collected postoperatively at three and 12 months.


Bone & Joint 360
Vol. 8, Issue 2 | Pages 33 - 35
1 Apr 2019


Bone & Joint Research
Vol. 8, Issue 2 | Pages 49 - 54
1 Feb 2019
Stravinskas M Nilsson M Vitkauskiene A Tarasevicius S Lidgren L

Objectives. The aim of this study was to analyze drain fluid, blood, and urine simultaneously to follow the long-term release of vancomycin from a biphasic ceramic carrier in major hip surgery. Our hypothesis was that there would be high local vancomycin concentrations during the first week with safe low systemic trough levels and a complete antibiotic release during the first month. Methods. Nine patients (six female, three male; mean age 75.3 years (sd 12.3; 44 to 84)) with trochanteric hip fractures had internal fixations. An injectable ceramic bone substitute, with hydroxyapatite in a calcium sulphate matrix, containing 66 mg of vancomycin per millilitre, was inserted to augment the fixation. The vancomycin elution was followed by simultaneously collecting drain fluid, blood, and urine. Results. The antibiotic concentration in the drain reached a peak during the first six hours post-surgery (mean 966.1 mg/l), which decreased linearly to a mean value of 88.3 mg/l at 2.5 days. In the urine, the vancomycin concentration reached 99.8 mg/l during the first two days, followed by a logarithmic decrease over the next two weeks to reach 0 mg/l at 20 days. The systemic concentration of vancomycin measured in blood serum was low and decreased linearly from 2.17 mg/l at one hour post-surgery to 0 mg/l at four days postoperatively. Conclusion. This is the first long-term pharmacokinetic study that reports vancomycin release from a biphasic injectable ceramic bone substitute. The study shows initial high targeted local vancomycin levels, sustained and complete release at three weeks, and systemic concentrations well below toxic levels. The plain ceramic bone substitute has been proven to regenerate bone but should also be useful in preventing bone infection. Cite this article: M. Stravinskas, M. Nilsson, A. Vitkauskiene, S. Tarasevicius, L. Lidgren. Vancomycin elution from a biphasic ceramic bone substitute. Bone Joint Res 2019;8:49–54. DOI: 10.1302/2046-3758.82.BJR-2018-0174.R2


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 83 - 91
1 Jan 2019
Whitehouse MR Berstock JR Kelly MB Gregson CL Judge A Sayers A Chesser TJ

Aims. The aim of this study was to investigate the association between the type of operation used to treat a trochanteric fracture of the hip and 30-day mortality. Patients and Methods. Data on 82 990 patients from the National Hip Fracture Database were analyzed using generalized linear models with incremental case-mix adjustment for patient, non-surgical and surgical characteristics, and socioeconomic factors. Results. The use of short and long intramedullary nails was associated with an increase in 30-day mortality (adjusted odds ratio (OR) 1.125, 95% confidence interval (CI) 1.040 to 1.218; p = 0.004) compared with the use of sliding hip screws (12.5% increase). If this were causative, it would represent 98 excess deaths over the four-year period of the study and one excess death would be caused by treating 112 patients with an intramedullary nail rather than a sliding hip screw. Conclusion. There is a 12.5% increase in the risk of 30-day mortality associated with the use of an intramedullary nail compared with a sliding hip screw in the treatment of a trochanteric fractures of the hip


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 92 - 95
1 Jan 2019
Harris IA Cuthbert A de Steiger R Lewis P Graves SE

Aims

Displaced femoral neck fractures (FNF) may be treated with partial (hemiarthroplasty, HA) or total hip arthroplasty (THA), with recent recommendations advising that THA be used in community-ambulant patients. This study aims to determine the association between the proportion of FNF treated with THA and year of surgery, day of the week, surgeon practice, and private versus public hospitals, adjusting for known confounders.

Patients and Methods

Data from 67 620 patients in the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) from 1999 to 2016 inclusive were used to generate unadjusted and adjusted analyses of the associations between patient, time, surgeon and institution factors, and the proportion of FNF treated with THA.


The Bone & Joint Journal
Vol. 100-B, Issue 9 | Pages 1157 - 1161
1 Sep 2018
Brown TS Fehring KA Ollivier M Mabry TM Hanssen AD Abdel MP

Aims

Recurrent infection following two-stage revision total hip arthroplasty (THA) for prosthetic joint infection (PJI) is a devastating complication. The purpose of this study was to report the survival of repeat two-stage revision hip arthroplasty, describe complications, and identify risk factors for failure.

Patients and Methods

We retrospectively identified 19 hips (19 patients) that had undergone repeat two-stage revision THA for infection between 2000 to 2013. There were seven female patients (37%) and the mean age was 60 years (30 to 85). Survival free from revision was assessed via Kaplan–Meier analysis. The patients were classified according to the Musculoskeletal Infection Society (MSIS) system, and risk factors for failure were identified. Mean follow-up was four years (2 to 11).


Bone & Joint 360
Vol. 7, Issue 4 | Pages 12 - 15
1 Aug 2018


The Bone & Joint Journal
Vol. 100-B, Issue 7 | Pages 853 - 861
1 Jul 2018
Leunig M Hutmacher JE Ricciardi BF Impellizzeri FM Rüdiger HA Naal FD

Aims

The classical longitudinal incision used for the direct anterior approach (DAA) to the hip does not follow the tension lines of the skin and can lead to impaired wound healing and poor cosmesis. The purpose of this retrospective study was to determine the satisfaction with the scar, and functional and radiographic outcomes comparing the classic longitudinal incision with a modified skin crease ‘bikini’ when the DAA is used for total hip arthroplasty (THA).

Patients and Methods

A total of 964 patients (51% female; 59% longitudinal, 41% ‘bikini’) completed a follow-up questionnaire between two and four years postoperatively, including the Oxford Hip Score (OHS), the University of North Carolina ‘4P’ scar scale (UNC4P) and two items for assessing the aesthetic appearance of the scar and symptoms of numbness. The positioning of the components, rates of heterotopic ossification (HO) and rates of revision were assessed.


Bone & Joint 360
Vol. 7, Issue 3 | Pages 10 - 12
1 Jun 2018


Bone & Joint 360
Vol. 7, Issue 2 | Pages 12 - 15
1 Apr 2018


The Bone & Joint Journal
Vol. 100-B, Issue 3 | Pages 361 - 369
1 Mar 2018
Sprague S Bhandari M Heetveld MJ Liew S Scott T Bzovsky S Heels-Ansdell D Zhou Q Swiontkowski M Schemitsch EH

Aims

The primary aim of this prognostic study was to identify baseline factors associated with physical health-related quality of life (HRQL) in patients after a femoral neck fracture. The secondary aims were to identify baseline factors associated with mental HRQL, hip function, and health utility.

Patients and Methods

Patients who were enrolled in the Fixation using Alternative Implants for the Treatment of Hip Fractures (FAITH) trial completed the 12-item Short Form Health Survey (SF-12), Western Ontario and McMaster Universities Arthritis Index, and EuroQol 5-Dimension at regular intervals for 24 months. We conducted multilevel mixed models to identify factors potentially associated with HRQL.


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1210 - 1215
1 Sep 2017
Parker MJ Cawley S

Aims. To compare the outcomes for trochanteric fractures treated with a sliding hip screw (SHS) or a cephalomedullary nail. Patients and Methods. A total of 400 patients with a trochanteric hip fracture were randomised to receive a SHS or a cephalomedullary nail (Targon PFT). All surviving patients were followed up to one year from injury. Functional outcome was assessed by a research nurse blinded to the implant used. Results. Recovery of mobility, as assessed by a mobility scale, was superior for those treated with the intramedullary nail compared with the SHS at eight weeks, three and nine months (p-values between 0.01 and 0.04), the difference at six and 12 months was not statistically significant (p = 0.15 and p = 0.18 respectively). The mean difference was around 0.4 points (0.3 to 0.5) on a nine point scale. Surgical time for the nail was four minutes less than that for the SHS (p < 0.001). Fracture healing complications were similar for the two groups. There were no statistically significant differences between implants for any other recorded outcomes including the need for post-operative blood transfusion, wound healing complications, general medical complications, hospital stay or mortality. Conclusion. This study confirms the findings of a previous study that both methods of treatment produce similar results, although intramedullary fixation does result in marginally improved regain of mobility in comparison with the SHS. Cite this article: Bone Joint J 2017;99-B:1210–15


Bone & Joint Research
Vol. 6, Issue 8 | Pages 481 - 488
1 Aug 2017
Caruso G Bonomo M Valpiani G Salvatori G Gildone A Lorusso V Massari L

Objectives

Intramedullary fixation is considered the most stable treatment for pertrochanteric fractures of the proximal femur and cut-out is one of the most frequent mechanical complications. In order to determine the role of clinical variables and radiological parameters in predicting the risk of this complication, we analysed the data pertaining to a group of patients recruited over the course of six years.

Methods

A total of 571 patients were included in this study, which analysed the incidence of cut-out in relation to several clinical variables: age; gender; the AO Foundation and Orthopaedic Trauma Association classification system (AO/OTA); type of nail; cervical-diaphyseal angle; surgical wait times; anti-osteoporotic medication; complete post-operative weight bearing; and radiological parameters (namely the lag-screw position with respect to the femoral head, the Cleveland system, the tip-apex distance (TAD), and the calcar-referenced tip-apex distance (CalTAD)).


Bone & Joint Research
Vol. 6, Issue 7 | Pages 405 - 413
1 Jul 2017
Matharu GS Judge A Murray DW Pandit HG

Objectives

Few studies have assessed outcomes following non-metal-on-metal hip arthroplasty (non-MoMHA) revision surgery performed for adverse reactions to metal debris (ARMD). We assessed outcomes following non-MoMHA revision surgery performed for ARMD, and identified predictors of re-revision.

Methods

We performed a retrospective observational study using data from the National Joint Registry for England and Wales. All non-MoMHAs undergoing revision surgery for ARMD between 2008 and 2014 were included (185 hips in 185 patients). Outcome measures following ARMD revision were intra-operative complications, mortality and re-revision surgery. Predictors of re-revision were identified using Cox regression.


Bone & Joint Research
Vol. 6, Issue 4 | Pages 204 - 207
1 Apr 2017
Fernandez MA Aquilina A Achten J Parsons N Costa ML Griffin XL

Objectives. The Sliding Hip Screw (SHS) is commonly used to treat trochanteric hip fractures. Fixation failure is a devastating complication requiring complex revision surgery. One mode of fixation failure is lag screw cut-out which is greatest in unstable fracture patterns and when the tip-apex distance of the lag screw is > 25 mm. The X-Bolt Dynamic Hip Plating System (X-Bolt Orthopaedics, Dublin, Ireland) is a new device which aims to reduce this risk of cut-out. However, some surgeons have reported difficulty minimising the tip-apex distance with subsequent concerns that this may lead to an increased risk of cut-out. Patients and Methods. We measured the tip-apex distance from the intra-operative radiographs of 93 unstable trochanteric hip fractures enrolled in a randomised controlled trial (Warwick Hip Trauma Evaluation, WHiTE One trial). Participants were treated with either the sliding hip screw or the X-Bolt dynamic hip plating system. We also recorded the incidence of cut-out in both groups, at a median follow-up time of 17 months. Results. There was a significantly increased tip-apex distance with the use of the X-Bolt (mean difference 3.7mm (95% confidence interval 1.58 to 5.73); SHS mean 17.1 mm, X-Bolt mean 20.8; p = 0.001. However, this was not associated with an increased incidence of cut-out at a median follow-up time of 17 months, with three cut-outs (6%) in the SHS group and 0 (0%) in the X-Bolt group. Conclusion. The X-Bolt is a safe implant with no increased risk for cut-out. Concerns about minimising the tip-apex distance may be justified but do not appear to be clinically important. Cite this article: M. A. Fernandez, A. Aquilina, J. Achten, N. Parsons, M. L. Costa, X. L. Griffin. The tip-apex distance in the X-Bolt dynamic plating system. Bone Joint Res 2017;6:–207. DOI: 10.1302/2046-3758.64.BJR-2015-0016.R2


The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 175 - 183
1 Feb 2017
Morita D Hasegawa Y Okura T Osawa Y Ishiguro N

Aims

Transtrochanteric rotational osteotomy (TRO) is performed for young patients with non-traumatic osteonecrosis of the femoral head (ONFH) to preserve the hip. We aimed to investigate the long-term outcomes and the risk factors for failure 15 years after this procedure.

Patients and Methods

This study included 95 patients (111 hips) with a mean age of 40 years (21 to 64) who underwent TRO for ONFH. The mean follow-up was 18.2 years (3 to 26). Kaplan–Meier survivorship analyses were performed with conversion to total hip arthroplasty (THA) and radiological failure due to secondary collapse of the femoral head or osteoarthritic changes as the endpoint. Multivariate analyses were performed to assess risk factors for each outcome.


The Bone & Joint Journal
Vol. 98-B, Issue 12 | Pages 1611 - 1619
1 Dec 2016
Wilson MJ Hook S Whitehouse SL Timperley AJ Gie GA

Aims

Femoral impaction bone grafting was first developed in 1987 using morselised cancellous bone graft impacted into the femoral canal in combination with a cemented, tapered, polished stem. We describe the evolution of this technique and instrumentation since that time.

Patients and Methods

Between 1987 and 2005, 705 revision total hip arthroplasties (56 bilateral) were performed with femoral impaction grafting using a cemented femoral stem. All surviving patients were prospectively followed for a mean of 14.7 years (9.8 to 28.3) with no loss to follow-up. By the time of the final review, 404 patients had died.


Bone & Joint Research
Vol. 5, Issue 9 | Pages 427 - 435
1 Sep 2016
Stravinskas M Horstmann P Ferguson J Hettwer W Nilsson M Tarasevicius S Petersen MM McNally MA Lidgren L

Objectives. Deep bone and joint infections (DBJI) are directly intertwined with health, demographic change towards an elderly population, and wellbeing. The elderly human population is more prone to acquire infections, and the consequences such as pain, reduced quality of life, morbidity, absence from work and premature retirement due to disability place significant burdens on already strained healthcare systems and societal budgets. DBJIs are less responsive to systemic antibiotics because of poor vascular perfusion in necrotic bone, large bone defects and persistent biofilm-based infection. Emerging bacterial resistance poses a major threat and new innovative treatment modalities are urgently needed to curb its current trajectory. Materials and Methods. We present a new biphasic ceramic bone substitute consisting of hydroxyapatite and calcium sulphate for local antibiotic delivery in combination with bone regeneration. Gentamicin release was measured in four setups: 1) in vitro elution in Ringer’s solution; 2) local elution in patients treated for trochanteric hip fractures or uncemented hip revisions; 3) local elution in patients treated with a bone tumour resection; and 4) local elution in patients treated surgically for chronic corticomedullary osteomyelitis. Results. The release pattern in vitro was comparable with the obtained release in the patient studies. No recurrence was detected in the osteomyelitis group at latest follow-up (minimum 1.5 years). Conclusions. This new biphasic bone substitute containing antibiotics provides safe prevention of bone infections in a range of clinical situations. The in vitro test method predicts the in vivo performance and makes it a reliable tool in the development of future antibiotic-eluting bone-regenerating materials. Cite this article: M. Stravinskas, P. Horstmann, J. Ferguson, W. Hettwer, M. Nilsson, S. Tarasevicius, M. M. Petersen, M. A. McNally, L. Lidgren. Pharmacokinetics of gentamicin eluted from a regenerating bone graft substitute: In vitro and clinical release studies. Bone Joint Res 2016;5:427–435. DOI: 10.1302/2046-3758.59.BJR-2016-0108.R1


The Bone & Joint Journal
Vol. 98-B, Issue 6 | Pages 840 - 845
1 Jun 2016
Chesser TJS Fox R Harding K Halliday R Barnfield S Willett K Lamb S Yau C Javaid MK Gray AC Young J Taylor H Shah K Greenwood R

Aims. We wished to assess the feasibility of a future randomised controlled trial of parathyroid hormone (PTH) supplements to aid healing of trochanteric fractures of the hip, by an open label prospective feasibility and pilot study with a nested qualitative sub study. This aimed to inform the design of a future powered study comparing the functional recovery after trochanteric hip fracture in patients undergoing standard care, versus those who undergo administration of subcutaneous injection of PTH for six weeks. Patients and Methods. We undertook a pilot study comparing the functional recovery after trochanteric hip fracture in patients 60 years or older, admitted with a trochanteric hip fracture, and potentially eligible to be randomised to either standard care or the administration of subcutaneous PTH for six weeks. Our desired outcomes were functional testing and measures to assess the feasibility and acceptability of the study. Results. A total of 724 patients were screened, of whom 143 (20%) were eligible for recruitment. Of these, 123 were approached and 29 (4%) elected to take part. However, seven patients did not complete the study. Compliance with the injections was 11 out of 15 (73%) showing the intervention to be acceptable and feasible in this patient population. Take home message: Only 4% of patients who met the inclusion criteria were both eligible and willing to consent to a study involving injections of PTH, so delivering this study on a large scale would carry challenges in recruitment and retention. Methodological and sample size planning would have to take this into account. PTH administration to patients to enhance fracture healing should still be considered experimental. Cite this article: Bone Joint J 2016;98-B:840–5


The Bone & Joint Journal
Vol. 98-B, Issue 4 | Pages 461 - 467
1 Apr 2016
Abdel MP Watts CD Houdek MT Lewallen DG Berry DJ

Aim and Methods

The goals of this study were to define the risk factors, nature, chronology, and treatment strategies adopted for periprosthetic femoral fractures in 32 644 primary total hip arthroplasties (THAs).

Results

There were 564 intra-operative fractures (1.7%); 529 during uncemented stem placement (3.0%) and 35 during cemented stem placement (0.23%). Intra-operative fractures were more common in females and patients over 65 years (p < 0.001). The majority occurred during placement of the femoral component (60%), and involved the calcar (69%). There were 557 post-operative fractures (20-year probability: 3.5%; 95% confidence interval (CI) 3.2 to 3.9); 335 fractures after placement of an uncemented stem (20-year probability: 7.7%; 95% CI 6.2 to 9.1) and 222 after placement of a cemented stem (20-year probability: 2.1%; 95% CI 1.8 to 2.5). The probability of a post-operative fracture within 30 days after an uncemented stem was ten times higher than a cemented stem. The most common post-operative fracture type was a Vancouver AG (32%; n = 135), with 67% occurring after a fall. In all, 36% (n = 152) were treated with revision arthroplasty.


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1031 - 1037
1 Aug 2015
da Assunção RE Pollard TCB Hrycaiczuk A Curry J Glyn-Jones S Taylor A

Periprosthetic femoral fracture (PFF) is a potentially devastating complication after total hip arthroplasty, with historically high rates of complication and failure because of the technical challenges of surgery, as well as the prevalence of advanced age and comorbidity in the patients at risk.

This study describes the short-term outcome after revision arthroplasty using a modular, titanium, tapered, conical stem for PFF in a series of 38 fractures in 37 patients.

The mean age of the cohort was 77 years (47 to 96). A total of 27 patients had an American Society of Anesthesiologists grade of at least 3. At a mean follow-up of 35 months (4 to 66) the mean Oxford Hip Score (OHS) was 35 (15 to 48) and comorbidity was significantly associated with a poorer OHS. All fractures united and no stem needed to be revised. Three hips in three patients required further surgery for infection, recurrent PFF and recurrent dislocation and three other patients required closed manipulation for a single dislocation. One stem subsided more than 5 mm but then stabilised and required no further intervention.

In this series, a modular, tapered, conical stem provided a versatile reconstruction solution with a low rate of complications.

Cite this article: Bone Joint J 2015;97-B:1031–7.


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 391 - 397
1 Mar 2015
van Embden D Stollenwerck GANL Koster LA Kaptein BL Nelissen RGHH Schipper IB

The aim of this study was to quantify the stability of fracture-implant complex in fractures after fixation. A total of 15 patients with an undisplaced fracture of the femoral neck, treated with either a dynamic hip screw or three cannulated hip screws, and 16 patients with an AO31-A2 trochanteric fracture treated with a dynamic hip screw or a Gamma Nail, were included. Radiostereometric analysis was used at six weeks, four months and 12 months post-operatively to evaluate shortening and rotation. Migration could be assessed in ten patients with a fracture of the femoral neck and seven with a trochanteric fracture. By four months post-operatively, a mean shortening of 5.4 mm (-0.04 to 16.1) had occurred in the fracture of the femoral neck group and 5.0 mm (-0.13 to 12.9) in the trochanteric fracture group. A wide range of rotation occurred in both types of fracture. Right-sided trochanteric fractures seem more rotationally stable than left-sided fractures. This prospective study shows that migration at the fracture site occurs continuously during the first four post-operative months, after which stabilisation occurs. This information may allow the early recognition of patients at risk of failure of fixation. Cite this article: Bone Joint J 2015;97-B:391–7


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 383 - 390
1 Mar 2015
Mariconda M Costa GG Cerbasi S Recano P Aitanti E Gambacorta M Misasi M

Several studies have reported the rate of post-operative mortality after the surgical treatment of a fracture of the hip, but few data are available regarding the delayed morbidity. In this prospective study, we identified 568 patients who underwent surgery for a fracture of the hip and who were followed for one year. Multivariate analysis was carried out to identify possible predictors of mortality and morbidity. The 30-day, four-month and one-year rates of mortality were 4.3%, 11.4%, and 18.8%, respectively. General complications and pre-operative comorbidities represented the basic predictors of mortality at any time interval (p < 0.01). In-hospital, four-month and one-year general complications occurred in 29.4%, 18.6% and 6.7% of patients, respectively. After adjusting for confounding variables, comorbidities and poor cognitive status determined the likelihood of early and delayed general complications, respectively (p < 0.001). Operative delay was the main predictor of the length of hospital stay (p < 0.001) and was directly related to in-hospital (p = 0.017) and four-month complications (p = 0.008).

Cite this article: Bone Joint J 2015;97-B:383–90


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 36 - 42
1 Nov 2014
Sheth NP Melnic CM Paprosky WG

Acetabular bone loss is a challenging problem facing the revision total hip replacement surgeon. Reconstruction of the acetabulum depends on the presence of anterosuperior and posteroinferior pelvic column support for component fixation and stability. The Paprosky classification is most commonly used when determining the location and degree of acetabular bone loss. Augments serve the function of either providing primary construct stability or supplementary fixation.

When a pelvic discontinuity is encountered we advocate the use of an acetabular distraction technique with a jumbo cup and modular porous metal acetabular augments for the treatment of severe acetabular bone loss and associated chronic pelvic discontinuity.

Cite this article: Bone Joint J 2014;96-B(11 Suppl A):36–42.


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1185 - 1191
1 Sep 2014
Middleton RG Uzoigwe CE Young PS Smith R Gosal HS Holt G

We aimed to determine whether cemented hemiarthroplasty is associated with a higher post-operative mortality and rate of re-operation when compared with uncemented hemiarthroplasty. Data on 19 669 patients, who were treated with a hemiarthroplasty following a fracture of the hip in a nine-year period from 2002 to 2011, were extracted from NHS Scotland’s acute admission database (Scottish Morbidity Record, SMR01). We investigated the rate of mortality at day 0, 1, 7, 30, 120 and one-year post-operatively using 12 case-mix variables to determine the independent effect of the method of fixation. At day 0, those with a cemented hemiarthroplasty had a higher rate of mortality (p < 0.001) compared with those with an uncemented hemiarthroplasty, equivalent to one extra death per 424 procedures. By day one this had become one extra death per 338 procedures. Increasing age and the five-year co-morbidity score were noted as independent risk factors. By day seven, the cumulative rate of mortality was less for cemented hemiarthroplasty though this did not reach significance until day 120. The rate of re-operation was significantly higher for uncemented hemiarthroplasty. Despite adjusting for 12 confounding variables, these only accounted for 15% of the observed variability.

The debate about the choice of the method of fixation for a hemiarthroplasty with respect to the rate of mortality or the risk of re-operation may be largely superfluous. Our results suggest that uncemented hemiarthroplasties may have a role to play in elderly patients with significant co-morbid disease.

Cite this article: Bone Joint J 2014;96-B:1185–91.


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1192 - 1197
1 Sep 2014
Egol KA Marcano AI Lewis L Tejwani NC McLaurin TM Davidovitch RI

In March 2012, an algorithm for the treatment of intertrochanteric fractures of the hip was introduced in our academic department of Orthopaedic Surgery. It included the use of specified implants for particular patterns of fracture. In this cohort study, 102 consecutive patients presenting with an intertrochanteric fracture were followed prospectively (post-algorithm group). Another 117 consecutive patients who had been treated immediately prior to the implementation of the algorithm were identified retrospectively as a control group (pre-algorithm group). The total cost of the implants prior to implementation of the algorithm was $357 457 (mean: $3055 (1947 to 4133)); compared with $255 120 (mean: $2501 (1052 to 4133)) after its implementation. There was a trend toward fewer complications in patients who were treated using the algorithm (33% pre- versus 22.5% post-algorithm; p = 0.088). Application of the algorithm to the pre-algorithm group revealed a potential overall cost saving of $70 295.

The implementation of an evidence-based algorithm for the treatment of intertrochanteric fractures reduced costs while maintaining quality of care with a lower rate of complications and re-admissions.

Cite this article: Bone Joint J 2014;96-B:1192–7.


The Bone & Joint Journal
Vol. 96-B, Issue 8 | Pages 1035 - 1040
1 Aug 2014
Meling T Nawab A Harboe K Fosse L

An atypical femoral fracture (AFF), with a transverse fracture radiologically through the lateral cortex is a rare but serious condition. In order to improve our ability to identify patients with this condition, we retrospectively surveyed all subtrochanteric, peri-implant and diaphyseal femoral fractures in patients aged ≥ 65 years who underwent surgical treatment at our hospital between 2004 and 2011.

We describe the incidence of atypical fractures and their characteristics, with observational data including a review of the hospital and general practitioner records. Clinical outcomes were evaluated using the Harris hip score (HHS) and the timed up-and-go (TUG) test.

Atypical fractures only occurred in women with an incidence of 9.8 per 100 000 person-years. The incidence in those who were treated with bisphosphonates was 79.0 per 100 000 person-years; eight of 17 fractures occurred around metal implants. There was a high incidence of delayed union and revision surgery. A total of nine patients (ten AFFs) were available for review at a mean follow-up of 36.5 months (10 to 104). The clinical outcome was poor with a mean HHS of 58.9 (95% CI 47.4 to 70.4) and a mean TUG test of 25.7 s (95% CI 12.7 to 38.8).

The delay in diagnosis and treatment of AFF may result from a lack of knowledge of this condition.

Cite this article: Bone Joint J 2014; 96-B:1035–40.


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 188 - 194
1 Feb 2014
Gilbody J Taylor C Bartlett GE Whitehouse SL Hubble MJW Timperley AJ Howell JR Wilson MJ

Impaction bone grafting for the reconstitution of bone stock in revision hip surgery has been used for nearly 30 years. Between 1995 and 2001 we used this technique in acetabular reconstruction, in combination with a cemented component, in 304 hips in 292 patients revised for aseptic loosening. The only additional supports used were stainless steel meshes placed against the medial wall or laterally around the acetabular rim to contain the graft. All Paprosky grades of defect were included. Clinical and radiographic outcomes were collected in surviving patients at a minimum of ten years after the index operation. Mean follow-up was 12.4 years (sd 1.5) (10.0 to 16.0). Kaplan–Meier survival with revision for aseptic loosening as the endpoint was 85.9% (95% CI 81.0 to 90.8) at 13.5 years. Clinical scores for pain relief remained satisfactory, and there was no difference in clinical scores between cups that appeared stable and those that appeared radiologically loose.

Cite this article: Bone Joint J 2014;96-B:188–94.


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 177 - 180
1 Feb 2014
Dossche L Noyez JF Ouedraogo W Kalmogho E

Total hip replacement (THR) still is a rare intervention in many African countries. In Burkina Faso it is not performed on a regular basis. A visiting programme for THR was started in a district hospital with no previous relevant experience. In this paper we present an analysis of the surgical technical problems and peri-operative complications of 152 THRs in 136 patients and three bipolar hemiarthroplasties in three patients undertaken in this new programme with limited orthopaedic equipment. There were 86 male and 53 female patients with a mean age of 49 years (21 to 78). We identified 77 intra-operative technical problems in 51 operations. There were 24 peri-operative complications in 21 patients, 17 of which were bony in nature. So far, ten revision THRs have been performed in nine patients.

Regular analysis of the technical problems and complications was used to improve quality, and we identified patient selection adapted to the local circumstances as important to avoid complications. Our reflections on the problems encountered in initiating such a programme may be of help to other teams planning similar projects.

Cite this article: Bone Joint J 2014;96-B:177–80.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 53 - 56
1 Nov 2013
Su EP Barrack RL

Cementless femoral stems are currently preferred for total hip replacement (THR) in the United States. Improvements in stem design, instrumentation and surgical technique have made this technology highly successful, reproducible, and applicable to the vast majority of patients requiring a THR. However, there are ongoing developments in some aspects of stem design that influence clinical results, the incidence of complications and their inherent adaptability in accommodating the needs of individual patients. Here we examine some of these design features.

Cite this article: Bone Joint J 2013;95-B, Supple A:53–6.


Bone & Joint Research
Vol. 2, Issue 10 | Pages 206 - 209
1 Oct 2013
Griffin XL McArthur J Achten J Parsons N Costa ML

Fractures of the proximal femur are one of the greatest challenges facing the medical community, constituting a heavy socioeconomic burden worldwide. Controversy exists regarding the optimal treatment for patients with unstable trochanteric proximal femoral fractures. The recognised treatment alternatives are extramedullary fixation usually with a sliding hip screw and intramedullary fixation with a cephalomedullary nail. Current evidence suggests that best results and lowest complication rates occur using a sliding hip screw. Complications in these difficult fractures are relatively common regardless of type of treatment. We believe that a novel device, the X-Bolt dynamic plating system, may offer superior fixation over a sliding hip screw with lower reoperation risk and better function. We therefore propose to investigate the clinical effectiveness of the X-bolt dynamic plating system compared with standard sliding hip screw fixation within the framework of a the larger WHiTE (Warwick Hip Trauma Evaluation) Comprehensive Cohort Study. Cite this article: Bone Joint Res 2013;2:206–9


The Bone & Joint Journal
Vol. 95-B, Issue 9 | Pages 1250 - 1254
1 Sep 2013
Lakstein D Hendel D Haimovich Y Feldbrin Z

The purpose of this study was to identify changing trends in the pattern of distribution of the type and demographics of fractures of the hip in the elderly between 2001 and 2010. A retrospective cross-sectional comparison was conducted between 179 fractures of the hip treated in 2001, 357 treated in 2006 and 454 treated in 2010. Patients aged < 60 years and those with pathological and peri-prosthetic fractures were excluded. Fractures were classified as stable extracapsular, unstable extracapsular or intracapsular fractures.

The mean age of the 179 patients (132 women (73.7%)) treated in 2001 was 80.8 years (60 to 96), 81.8 years (61 to 101) in the 357 patients (251 women (70.3%)) treated in 2006 and 82.0 years (61 to 102) in the 454 patients (321 women (70.1%)) treated in 2010 (p = 0.17). There was no difference in the gender distribution between the three study years (p = 0.68).

The main finding was a steep rise in the proportion of unstable peritrochanteric fractures. The proportion of unstable extracapsular fractures was 32% (n = 57) in 2001, 35% (n = 125) in 2006 and 45% (n = 204) in 2010 (p < 0.001). This increase was not significant in patients aged between 60 and 69 years (p = 0.84), marginally significant in those aged between 70 and 79 years (p = 0.04) and very significant in those aged > 80 years (p < 0.001). The proportion of intracapsular fractures did not change (p = 0.94).

At present, we face not only an increasing number of fractures of the hip, but more demanding and complex fractures in older patients than a decade ago. This study does not provide an explanation for this change.

Cite this article: Bone Joint J 2013;95-B:1250–4.


Bone & Joint Research
Vol. 2, Issue 5 | Pages 79 - 83
1 May 2013
Goffin JM Pankaj P Simpson AHRW Seil R Gerich TG

Objectives. Because of the contradictory body of evidence related to the potential benefits of helical blades in trochanteric fracture fixation, we studied the effect of bone compaction resulting from the insertion of a proximal femoral nail anti-rotation (PFNA). . Methods. We developed a subject-specific computational model of a trochanteric fracture (31-A2 in the AO classification) with lack of medial support and varied the bone density to account for variability in bone properties among hip fracture patients. Results. We show that for a bone density corresponding to 100% of the bone density of the cadaveric femur, there does not seem to be any advantage in using a PFNA with respect to the risk of blade cut-out. On the other hand, in a more osteoporotic femoral head characterised by a density corresponding to 75% of the initial bone density, local bone compaction around the helical blade provides additional bone purchase, thereby decreasing the risk of cut-out, as quantified by the volume of bone susceptible to yielding. Conclusions. Our findings indicate benefits of using a PFNA over an intramedullary nail with a conventional lag screw and suggest that any clinical trial reporting surgical outcomes regarding the use of helical blades should include a measure of the femoral head bone density as a covariable


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 26 - 31
1 Nov 2012
Mayle RE Della Valle CJ

The purpose of this paper is to discuss the risk factors, prevention strategies, classification, and treatment of intra-operative femur fractures sustained during primary and revision total hip arthroplasty.


Bone & Joint Research
Vol. 1, Issue 11 | Pages 310 - 314
1 Nov 2012
Griffin XL Achten J Parsons N Boardman F Griffiths F Costa ML

Fractures of the proximal femur are one of the greatest challenges facing the medical community, constituting a heavy socioeconomic burden worldwide. The National Hip Fracture Audit currently provides a framework for service evaluation. This evaluation is based upon the assessment of process rather than assessment of patient-centred outcome and therefore it fails to provide meaningful data regarding the clinical effectiveness of treatments. This study aims to capture data from the cohort of patients who present with a fracture of the proximal femur at a single United Kingdom Major Trauma Centre. Patient-centred outcomes will be recorded and provide a baseline cohort within which to test the clinical effectiveness of experimental interventions.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 969 - 973
1 Jul 2012
Iwata T Nozawa S Dohjima T Yamamoto T Ishimaru D Tsugita M Maeda M Shimizu K

A delay in establishing the diagnosis of an occult fracture of the hip that remains unrecognised after plain radiography can result in more complex treatment such as an arthroplasty being required. This might be avoided by earlier diagnosis using MRI. The aim of this study was to investigate the best MR imaging sequence for diagnosing such fractures. From a consecutive cohort of 771 patients admitted between 2003 and 2011 with a clinically suspected fracture of the hip, we retrospectively reviewed the MRI scans of the 35 patients who had no evidence of a fracture on their plain radiographs. In eight of these patients MR scanning excluded a fracture but the remaining 27 patients had an abnormal scan: one with a fracture of the pubic ramus, and in the other 26 a T1-weighted coronal MRI showed a hip fracture with 100% sensitivity. T2-weighted imaging was undertaken in 25 patients, in whom the diagnosis could not be established with this scanning sequence alone, giving a sensitivity of 84.0% for T2-weighted imaging.

If there is a clinical suspicion of a hip fracture with normal radiographs, T1-weighted coronal MRI is the best sequence of images for identifying a fracture.


Bone & Joint Research
Vol. 1, Issue 6 | Pages 104 - 110
1 Jun 2012
Swinteck BJ Phan DL Jani J Owen JR Wayne JS Mounasamy V

Objectives

The use of two implants to manage concomitant ipsilateral femoral shaft and proximal femoral fractures has been indicated, but no studies address the relationship of dynamic hip screw (DHS) side plate screws and the intramedullary nail where failure might occur after union. This study compares different implant configurations in order to investigate bridging the gap between the distal DHS and tip of the intramedullary nail.

Methods

A total of 29 left synthetic femora were tested in three groups: 1) gapped short nail (GSN); 2) unicortical short nail (USN), differing from GSN by the use of two unicortical bridging screws; and 3) bicortical long nail (BLN), with two angled bicortical and one unicortical bridging screws. With these findings, five matched-pairs of cadaveric femora were tested in two groups: 1) unicortical long nail (ULN), with a longer nail than USN and three bridging unicortical screws; and 2) BLN. Specimens were axially loaded to 22.7 kg (50 lb), and internally rotated 90°/sec until failure.


Bone & Joint 360
Vol. 1, Issue 3 | Pages 24 - 26
1 Jun 2012

The June 2012 Trauma Roundup. 360. looks at: nerve injuries of warfare; the medical complications of earthquakes; the measuring of tissue pressures in compartment syndrome; the risk of plunging through the bone when drilling; bony nonunion and negative pressure therapy; surgery for the posteriorly dislocated hip; whether to use the sliding screw or intramedullary nail for the trochanteric fracture; antegrade interlocking nailing for the distal femoral fracture; and gunshot wounds to the pancreas


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 3 | Pages 391 - 397
1 Mar 2012
Parker MJ Bowers TR Pryor GA

In a randomised trial involving 598 patients with 600 trochanteric fractures of the hip, the fractures were treated with either a sliding hip screw (n = 300) or a Targon PF intramedullary nail (n = 300). The mean age of the patients was 82 years (26 to 104). All surviving patients were reviewed at one year with functional outcome assessed by a research nurse blinded to the treatment used. The intramedullary nail was found to have a slightly increased mean operative time (46 minutes (. sd. 12.3) versus 49 minutes (. sd. 12.7), p < 0.001) and an increased mean radiological screening time (0.3 minutes (. sd. 0.2) versus 0.5 minutes (. sd. 0.3), p <  0.001). Operative difficulties were more common with the intramedullary nail. There was no statistically significant difference between implants for wound healing complications (p = 1), or need for post-operative blood transfusion (p = 1), and medical complications were similarly distributed in both groups. There was a tendency to fewer revisions of fixation or conversion to an arthroplasty in the nail group, although the difference was not statistically significant (nine versus three cases, p = 0.14). The extent of shortening, loss of hip flexion, mortality and degree of residual pain were similar in both groups. The recovery of mobility was superior for those treated with the intramedullary nails (p = 0.01 at one year from injury). In summary, both implants produced comparable results but there was a tendency to better return of mobility for those treated with the intramedullary nail


Bone & Joint 360
Vol. 1, Issue 1 | Pages 20 - 21
1 Feb 2012


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 12 | Pages 1602 - 1609
1 Dec 2011
Malviya A Ramaskandhan JR Bowman R Hashmi M Holland JP Kometa S Lingard E

The aim of this study was to investigate the possible benefit of large-head metal-on-metal bearing on a stem for primary hip replacement compared with a 28 mm diameter conventional metal-on-polyethylene bearing in a prospective randomised controlled trial. We investigated cemented stem behaviour between these two different bearings using Einzel-Bild-Röntgen-Analyse, clinical and patient reported measures (Harris hip score, Western Ontario and McMaster Universities osteoarthritis index, Short Form-36 and satisfaction) and whole blood metal ion levels at two years. A power study indicated that 50 hips were needed in each group to detect subsidence of > 5 mm at two years with a p-value of < 0.05.

Significant improvement (p < 0.001) was found in the mean clinical and patient reported outcomes at two years for both groups. Comparison of outcomes between the groups at two years showed no statistically significant difference for mean stem migration, clinical and patient reported outcomes; except overall patient satisfaction which was higher for metal-on-metal group (p = 0.05). Metal ion levels were raised above the Medicines and Healthcare products Regulatory Agency advised safety level (7 µg per litre) in 20% of the metal-on-metal group and in one patient in metal-on-polyethylene group (who had a metal-on-metal implant on the contralateral side). Two patients in the metal-on-metal group were revised, one for pseudotumour and one for peri-prosthetic fracture.

Use of large modular heads is associated with a risk of raised whole blood metal ion levels despite using a proven bearing from resurfacing. The head-neck junction or excess stem micromotion are possibly the weak links warranting further research.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 273 - 273
1 Feb 2011
Kolar MK Joseph S McLaren A

We present the case of a young male patient with inferior dislocation of the hip and postulate a possible mechanism for this extremely rare injury.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1332 - 1337
1 Oct 2010
Leung KS Tang N Cheung LWH Ng E

Fluoronavigation is an image-guided technology which uses intra-operative fluoroscopic images taken under a real-time tracking system and registration to guide surgical procedures. With the skeleton and the instrument registered, guidance under an optical tracking system is possible, allowing fixation of the fracture and insertion of an implant. This technology helps to minimise exposure to x-rays, providing multiplanar views for monitoring and accurate positioning of implants. It allows real-time interactive quantitative data for decision-making and expands the application of minimally invasive surgery. In orthopaedic trauma its use can be further enhanced by combining newer imaging technologies such as intra-operative three-dimensional fluoroscopy and optical image guidance, new advances in software for fracture reduction, and new tracking mechanisms using electromagnetic technology. The major obstacles for general and wider applications are the inability to track individual fracture fragments, no navigated real-time fracture reduction, and the lack of an objective assessment method for cost-effectiveness.

We believe that its application will go beyond the operating theatre and cover all aspects of patient management, from pre-operative planning to intra-operative guidance and postoperative rehabilitation.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 9 | Pages 1303 - 1305
1 Sep 2010
Benum P Aamodt A Nordsletten L

Traditional techniques for the insertion of femoral stems in arthroplasty of the hip in osteopetrosis carry a considerable risk of penetration of the femoral cortex and intra-operative fractures, due to obliteration of the intramedullary cavity and greatly increased stiffness and brittleness of the bone. In order to reduce the risk of such complications we manufactured a customised stem and a computer-based guiding device for the preparation of a cavity within the proximal femur. This system was used successfully in three hips in two patients. We describe the system and the operative technique.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 116 - 122
1 Jan 2010
Parker MI Pryor G Gurusamy K

We undertook a prospective randomised controlled trial involving 400 patients with a displaced intracapsular fracture of the hip to determine whether there was any difference in outcome between treatment with a cemented Thompson hemiarthroplasty and an uncemented Austin-Moore prosthesis. The surviving patients were followed up for between two and five years by a nurse blinded to the type of prosthesis used.

The mean age of the patients was 83 years (61 to 104) and 308 (77%) were women. The degree of residual pain was less in those treated with a cemented prosthesis (p < 0.0001) three months after surgery. Regaining mobility was better in those treated with a cemented implant (p = 0.005) at six months after operation. No statistically significant difference was found between the two groups with regard to mortality, implant-related complications, re-operations or post-operative medical complications.

The use of a cemented Thompson hemiarthroplasty resulted in less pain and less deterioration in mobility than an uncemented Austin-Moore prosthesis with no increase in complications.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 8 | Pages 1064 - 1068
1 Aug 2009
Sankey RA Turner J Lee J Healy J Gibbons CER

An MR scan was performed on all patients who presented to our hospital with a clinical diagnosis of a fracture of the proximal femur, but who had no abnormality on plain radiographs. This was a prospective study of 102 consecutive patients over a ten-year period. There were 98 patients who fulfilled our inclusion criteria, of whom 75 were scanned within 48 hours of admission, with an overall mean time between admission and scanning of 2.4 days (0 to 10). A total of 81 patients (83%) had abnormalities detected on MRI; 23 (23%) required operative management.

The use of MRI led to the early diagnosis and treatment of occult hip pathology. We recommend that incomplete intertrochanteric fractures are managed non-operatively with protected weight-bearing. The study illustrates the high incidence of fractures which are not apparent on plain radiographs, and shows that MRI is useful when diagnosing other pathology such as malignancy, which may not be apparent on plain films.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 294 - 303
1 Mar 2009
Lindner T Kanakaris NK Marx B Cockbain A Kontakis G Giannoudis PV

Failure of fixation is a common problem in the treatment of osteoporotic fractures around the hip. The reinforcement of bone stock or of fixation of the implant may be a solution. Our study assesses the existing evidence for the use of bone substitutes in the management of these fractures in osteoporotic patients. Relevant publications were retrieved through Medline research and further scrutinised. Of 411 studies identified, 22 met the inclusion criteria, comprising 12 experimental and ten clinical reports. The clinical studies were evaluated with regard to their level of evidence. Only four were prospective and randomised. Polymethylmethacrylate and calcium-phosphate cements increased the primary stability of the implant-bone construct in all experimental and clinical studies, although there was considerable variation in the design of the studies. In randomised, controlled studies, augmentation of intracapsular fractures of the neck of the femur with calcium-phosphate cement was associated with poor long-term results. There was a lack of data on the long-term outcome for trochanteric fractures. Because there were only a few, randomised, controlled studies, there is currently poor evidence for the use of bone cement in the treatment of fractures of the hip


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 1013 - 1018
1 Aug 2008
Goto K Kawanabe K Akiyama H Morimoto T Nakamura T

We reviewed 44 consecutive revision hip replacements in 38 patients performed using the cement-in-cement technique. All were performed for acetabular loosening in the presence of a well-fixed femoral component. The mean follow-up was 5.1 years (2 to 10.1). Radiological analysis at final follow-up indicated no loosening of the femoral component, except for one case with a continuous radiolucent line in all zones and peri-prosthetic fracture which required further revision. Peri-operative complications included nine proximal femoral fractures (20.4%) and perforation of the proximal femur in one hip. In five hips wiring or fixation with a braided suture was undertaken but no additional augmentation was required. There was an improvement in the mean Japanese Orthopaedic Association score from 55.5 (28 to 81) pre-operatively to 77.8 (40 to 95) at final follow-up (p < 0.001). Revision using a cement-in-cement technique allows increased exposure for acetabular revision and is effective in the medium term. Further follow-up is required to assess the long-term results in the light of in vitro studies which have questioned the quality of the cement-in-cement bond.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1522 - 1524
1 Nov 2007
Kumagi M Ikeda S Uchida K Ono T Tsumara H

We carried out three total knee replacements with proximal realignment in two patients with severe osteoarthritis of the knee and congenital dislocation of the patella. During the operation, the femur and the tibia were cut according to the recommendations of the manufacturer of the implant. The femoral component was placed in external rotation and the centre of the tibial component aligned in relation to the tibial tuberosity with regard to rotation and translation. After making the bone cuts, the iliotibial tract was detached from Gerdy’s tubercle, the popliteus tendon divided, and the biceps femoris tendon elongated by Z-plasty. After the trial implants were positioned, a proximal re-alignment procedure was performed. One knee had deep infection. There was one dislocated patella which was repositioned, and walking ability was improved in all knees. We believe that the rotational alignment of a prosthesis is as important as the soft-tissue surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1488 - 1494
1 Nov 2007
Gorodetskyi IG Gorodnichenko AI Tursin PS Reshetnyak VK Uskov ON

We undertook a trial on 60 patients with AO 31A2 fractures of the hip who were randomised after stabilisation of the fracture into two equal groups, one of which received post-operative treatment using a non-invasive interactive neurostimulation device and the other with a sham device. All other aspects of their rehabilitation were the same. The treatment was continued for ten days after operation.

Outcome measurements included the use of a visual analogue scale for pain, the brief pain inventory and Ketorolac for post-operative control of pain, and an overall assessment of outcome by the surgeon. There were significantly better results for the patients receiving treatment by active electrical stimulation (repeated measures analysis of variance, p < 0.001). The findings of this pilot trial justify a larger study to determine if these results are more generally applicable.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 7 | Pages 879 - 886
1 Jul 2007
Howie DW Wimhurst JA McGee MA Carbone TA Badaruddin BS

We investigated 219 revisions of total hip replacement (THR) in 211 patients using a collarless double-taper cemented femoral component. The mean age of the patients was 72 years (30 to 90). The 137 long and 82 standard length stems were analysed separately. The mean follow-up was six years (2 to 18), and no patient was lost to follow-up.

Survival of the long stems to re-revision for aseptic loosening at nine years was 98% (95% confidence interval (CI) 94 to 100), and for the standard stems was 93% (95% CI 85 to 100). At five years, one long stem was definitely loose radiologically and one standard stem was probably loose. Pre-operative femoral bone deficiency did not influence the results for the long stems, and corrective femoral osteotomy was avoided, as were significant subsidence, major stress shielding and persistent thigh pain.

Because of these reliable results, cemented long collarless double-taper femoral components are recommended for routine revision THR in older patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 3 | Pages 421 - 421
1 Mar 2007


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1347 - 1350
1 Oct 2006
Karn NK Singh GK Kumar P Shrestha B Singh MP Gowda MJ

We conducted a randomised controlled trial to compare external fixation of trochanteric fractures of the femur with the more costly option of the sliding hip screw. Patients in both groups were matched for age (mean 67 years, 50 to 100) and gender. We excluded all pathological fractures, patients presenting at more than one week, fractures with subtrochanteric extension or reverse obliquity, multiple fractures or any bone and joint disease interfering with rehabilitation. The interval between injury and operation, the duration of surgery, the amount of blood loss, the length of hospital stay and the cost of treatment were all significantly higher in the sliding hip screw group (p < 0.05). The time to union, range of movement, mean Harris hip scores and Western Ontario and McMaster University knee scores were comparable at six months. The number of patients showing shortening or malrotation was too small to show a significant difference between the groups. Pin-track infection occurred in 18 patients (60%) treated with external fixation, whereas there was a single case of wound infection (3.3%) in the sliding hip screw group


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1272 - 1278
1 Oct 2006
Giannoudis PV Schneider E

Despite advances in the prevention and treatment of osteoporotic fractures, their prevalence continues to increase. Their operative treatment remains a challenge for the surgeon, often with unpredictable outcomes. This review highlights the current aspects of management of these fractures and focuses on advances in implant design and surgical technique.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 1053 - 1059
1 Aug 2006
Foss NB Kehlet H

Our aim was to determine the total blood loss associated with surgery for fracture of the hip and to identify risk factors for increased blood loss. We prospectively studied 546 patients with hip fracture. The total blood loss was calculated on the basis of the haemoglobin difference, the number of transfusions and the estimated blood volume. The hidden blood loss, in excess of that observed during surgery, varied from 547 ml (screws/ pins) to 1473 ml (intramedullary hip nail and screw) and was significantly associated with medical complications and increased hospital stay. The type of surgery, treatment with aspirin, intra-operative hypotension and gastro-intestinal bleeding or ulceration were all independent predictors of blood loss.

We conclude that total blood loss after surgery for hip fracture is much greater than that observed intra-operatively. Frequent post-operative measurements of haemoglobin are necessary to avoid anaemia.