Advertisement for orthosearch.org.uk
Results 1 - 35 of 35
Results per page:
The Bone & Joint Journal
Vol. 107-B, Issue 1 | Pages 10 - 18
1 Jan 2025
Lewis TL Barakat A Mangwani J Ramasamy A Ray R

Hallux valgus (HV) presents as a common forefoot deformity that causes problems with pain, mobility, footwear, and quality of life. The most common open correction used in the UK is the Scarf and Akin osteotomy, which has good clinical and radiological outcomes and high levels of patient satisfaction when used to treat a varying degrees of deformity. However, there are concerns regarding recurrence rates and long-term outcomes. Minimally invasive or percutaneous surgery (MIS) has gained popularity, offering the potential for similar clinical and radiological outcomes with reduced postoperative pain and smaller scars. Despite this, MIS techniques vary widely, hindering comparison and standardization. This review evaluates the evidence for both open Scarf and Akin osteotomy and newer-generation MIS techniques. Fourth-generation MIS emphasizes multiplanar rotational deformity correction through stable fixation. While MIS techniques show promise, their evidence mainly comprises single-surgeon case series. Comparative studies between open and MIS techniques suggest similar clinical and radiological outcomes, although MIS may offer advantages in scar length and less early postoperative pain. MIS may afford superior correction in severe deformity and lower recurrence rates due to correcting the bony deformity rather than soft-tissue correction. Recurrence remains a challenge in HV surgery, necessitating long-term follow-up and standardized outcome measures for assessment. Any comparison between the techniques requires comparative studies. Surgeons must weigh the advantages and risks of both open and MIS approaches in collaboration with patients to determine the most suitable treatment.

Cite this article: Bone Joint J 2025;107-B(1):10–18.


Bone & Joint Research
Vol. 13, Issue 12 | Pages 695 - 702
1 Dec 2024
Cordero García-Galán E Medel-Plaza M Pozo-Kreilinger JJ Sarnago H Lucía Ó Rico-Nieto A Esteban J Gomez-Barrena E

Aims

Electromagnetic induction heating has demonstrated in vitro antibacterial efficacy over biofilms on metallic biomaterials, although no in vivo studies have been published. Assessment of side effects, including thermal necrosis of adjacent tissue, would determine transferability into clinical practice. Our goal was to assess bone necrosis and antibacterial efficacy of induction heating on biofilm-infected implants in an in vivo setting.

Methods

Titanium-aluminium-vanadium (Ti6Al4V) screws were implanted in medial condyle of New Zealand giant rabbit knee. Study intervention consisted of induction heating of the screw head up to 70°C for 3.5 minutes after implantation using a portable device. Both knees were implanted, and induction heating was applied unilaterally keeping contralateral knee as paired control. Sterile screws were implanted in six rabbits, while the other six received screws coated with Staphylococcus aureus biofilm. Sacrifice and sample collection were performed 24, 48, or 96 hours postoperatively. Retrieved screws were sonicated, and adhered bacteria were estimated via drop-plate. Width of bone necrosis in retrieved femora was assessed through microscopic examination. Analysis was performed using non-parametric tests with significance fixed at p ≤ 0.05.


Bone & Joint Open
Vol. 4, Issue 6 | Pages 442 - 446
12 Jun 2023
Toda Y Iwata S Kobayashi E Ogura K Osaki S Fukushima S Mawatari M Kawai A

Aims

The risk of postoperative complications after resection of soft-tissue sarcoma in the medial thigh is higher than in other locations. This study investigated whether a vessel sealing system (VSS) could help reduce the risk of postoperative complications after wide resection of soft-tissue sarcoma in the medial thigh.

Methods

Of 285 patients who underwent wide resection for soft-tissue sarcoma between 2014 and 2021 at our institution, 78 patients with tumours in the medial thigh were extracted from our database. Information on clinicopathological characteristics, preoperative treatment, surgical treatment (use of VSS, blood loss volume, operating time), and postoperative course (complications, postoperative haemoglobin changes, total drainage volume, and drainage and hospitalization durations) were obtained from medical records. We statistically compared clinical outcomes between patients whose surgery did or did not use VSS (VSS and non-VSS groups, respectively).


Bone & Joint 360
Vol. 11, Issue 4 | Pages 17 - 21
1 Aug 2022


Bone & Joint 360
Vol. 10, Issue 6 | Pages 25 - 29
1 Dec 2021


The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1405 - 1411
3 Oct 2020
Martynov I Klink T Slowik V Stich R Zimmermann P Engel C Lacher M Boehm R

Aims

This exploratory randomized controlled trial (RCT) aimed to determine the splint-related outcomes when using the novel biodegradable wood-composite splint (Woodcast) compared to standard synthetic fibreglass (Dynacast) for the immobilization of undisplaced upper limb fractures in children.

Methods

An exploratory RCT was performed at a tertiary paediatric referral hospital between 1 June 2018 and 30 September 2019. The intention-to-treat population consisted of 170 patients (mean age 8.42 years (SD 3.42); Woodcast (WCG), n = 84, 57 male (67.9%); Dynacast (DNG), n = 86, 58 male (67.4%)). Patients with undisplaced upper limb fractures were randomly assigned to WCG or DNG treatment groups. Primary outcome was the stress stability of the splint material, defined as absence of any deformations or fractures within the splint during study period. Secondary outcomes included patient satisfaction and medical staff opinion. Additionally, biomechanical and chemical analysis of the splint samples was carried out.


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 967 - 980
1 Aug 2020
Chou TA Ma H Wang J Tsai S Chen C Wu P Chen W

Aims

The aims of this study were to validate the outcome of total elbow arthroplasty (TEA) in patients with rheumatoid arthritis (RA), and to identify factors that affect the outcome.

Methods

We searched PubMed, MEDLINE, Cochrane Reviews, and Embase from between January 2003 and March 2019. The primary aim was to determine the implant failure rate, the mode of failure, and risk factors predisposing to failure. A secondary aim was to identify the overall complication rate, associated risk factors, and clinical performance. A meta-regression analysis was completed to identify the association between each parameter with the outcome.


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 1048 - 1055
1 Aug 2020
Cox I Al Mouazzen L Bleibleh S Moldovan R Bintcliffe F Bache CE Thomas S

Aims

The Fassier Duval (FD) rod is a third-generation telescopic implant for children with osteogenesis imperfecta (OI). Threaded fixation enables proximal insertion without opening the knee or ankle joint. We have reviewed our combined two-centre experience with this implant.

Methods

In total, 34 children with a mean age of five years (1 to 14) with severe OI have undergone rodding of 72 lower limb long bones (27 tibial, 45 femoral) for recurrent fractures with progressive deformity despite optimized bone health and bisphosphonate therapy. Data were collected prospectively, with 1.5 to 11 years follow-up.


Bone & Joint 360
Vol. 8, Issue 3 | Pages 29 - 31
1 Jun 2019


Bone & Joint Research
Vol. 7, Issue 11 | Pages 609 - 619
1 Nov 2018
Pijls BG Sanders IMJG Kuijper EJ Nelissen RGHH

Objectives. Prosthetic joint infection (PJI) is a devastating complication following total joint arthroplasty. Non-contact induction heating of metal implants is a new and emerging treatment for PJI. However, there may be concerns for potential tissue necrosis. It is thought that segmental induction heating can be used to control the thermal dose and to limit collateral thermal injury to the bone and surrounding tissues. The purpose of this study was to determine the thermal dose, for commonly used metal implants in orthopaedic surgery, at various distances from the heating centre (HC). Methods. Commonly used metal orthopaedic implants (hip stem, intramedullary nail, and locking compression plate (LCP)) were heated segmentally using an induction heater. The thermal dose was expressed in cumulative equivalent minutes at 43°C (CEM43) and measured with a thermal camera at several different distances from the HC. A value of 16 CEM43 was used as the threshold for thermal damage in bone. Results. Despite high thermal doses at the HC (7161 CEM43 to 66 640 CEM43), the thermal dose at various distances from the HC was lower than 16 CEM43 for the hip stem and nail. For the fracture plate without corresponding metal screws, doses higher than 16 CEM43 were measured up to 5 mm from the HC. Conclusion. Segmental induction heating concentrates the thermal dose at the targeted metal implant areas and minimizes collateral thermal injury by using the non-heated metal as a heat sink. Implant type and geometry are important factors to consider, as they influence dissipation of heat and associated collateral thermal injury. Cite this article: B. G. Pijls, I. M. J. G. Sanders, E. J. Kuijper, R. G. H. H. Nelissen. Segmental induction heating of orthopaedic metal implants. Bone Joint Res 2018;7:609–619. DOI: 10.1302/2046-3758.711.BJR-2018-0080.R1


Bone & Joint 360
Vol. 6, Issue 6 | Pages 28 - 31
1 Dec 2017


Bone & Joint 360
Vol. 6, Issue 5 | Pages 42 - 44
1 Oct 2017
Ross A


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 554 - 560
1 Apr 2017
Tamai K Suzuki A Takahashi S Akhgar J Rahmani MS Hayashi K Ohyama S Nakamura H

Aims

We aimed to evaluate the temperature around the nerve root during drilling of the lamina and to determine whether irrigation during drilling can reduce the chance of nerve root injury.

Materials and Methods

Lumbar nerve roots were exposed to frictional heat by high-speed drilling of the lamina in a live rabbit model, with saline (room temperature (RT) or chilled saline) or without saline (control) irrigation. We measured temperatures surrounding the nerve root and made histological evaluations.


Bone & Joint 360
Vol. 5, Issue 6 | Pages 37 - 39
1 Dec 2016


The Bone & Joint Journal
Vol. 98-B, Issue 1 | Pages 117 - 124
1 Jan 2016
Takenaka S Hosono N Mukai Y Tateishi K Fuji T

Aims

The aim of this study was to determine whether chilled irrigation saline decreases the incidence of clinical upper limb palsy (ULP; a reduction of one grade or more on manual muscle testing; MMT), based on the idea that ULP results from thermal damage to the nerve roots by heat generated by friction during bone drilling.

Methods

Irrigation saline for drilling was used at room temperature (RT, 25.6°C) in open-door laminoplasty in 400 patients (RT group) and chilled to a mean temperature of 12.1°C during operations for 400 patients (low-temperature (LT) group). We assessed deltoid, biceps, and triceps brachii muscle strength by MMT. ULP occurring within two days post-operatively was categorised as early-onset palsy.


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1628 - 1633
1 Dec 2015
Elmadag M Uzer G Yildiz F Erden T Bilsel K Büyükpinarbasili N Üsümez A Bozdag E Sen C

This animal study compares different methods of performing an osteotomy, including using an Erbium-doped Yttrium Aluminum Garnet laser, histologically, radiologically and biomechanically. A total of 24 New Zealand rabbits were divided into four groups (Group I: multihole-drilling; Group II: Gigli saw; Group III: electrical saw blade and Group IV: laser). A proximal transverse diaphyseal osteotomy was performed on the right tibias of the rabbits after the application of a circular external fixator. The rabbits were killed six weeks after the procedure, the operated tibias were resected and radiographs taken.

The specimens were tested biomechanically using three-point bending forces, and four tibias from each group were examined histologically. Outcome parameters were the biomechanical stability of the tibias as assessed by the failure to load and radiographic and histological examination of the osteotomy site.

The osteotomies healed in all specimens both radiographically and histologically. The differences in the mean radiographic (p = 0.568) and histological (p = 0.71) scores, and in the mean failure loads (p = 0.180) were not statistically significant between the groups.

Different methods of performing an osteotomy give similar quality of union. The laser osteotomy, which is not widely used in orthopaedics is an alternative to the current methods.

Cite this article: Bone Joint J 2015;97-B:1628–33.


Bone & Joint Research
Vol. 3, Issue 5 | Pages 150 - 154
1 May 2014
M. Takamura K Maher P Nath T Su EP

Objectives

Metal-on-metal hip resurfacing (MOMHR) is available as an alternative option for younger, more active patients. There are failure modes that are unique to MOMHR, which include loosening of the femoral head and fractures of the femoral neck. Previous studies have speculated that changes in the vascularity of the femoral head may contribute to these failure modes. This study compares the survivorship between the standard posterior approach (SPA) and modified posterior approach (MPA) in MOMHR.

Methods

A retrospective clinical outcomes study was performed examining 351 hips (279 male, 72 female) replaced with Birmingham Hip Resurfacing (BHR, Smith and Nephew, Memphis, Tennessee) in 313 patients with a pre-operative diagnosis of osteoarthritis. The mean follow-up period for the SPA group was 2.8 years (0.1 to 6.1) and for the MPA, 2.2 years (0.03 to 5.2); this difference in follow-up period was statistically significant (p < 0.01). Survival analysis was completed using the Kaplan–Meier method.


The Bone & Joint Journal
Vol. 96-B, Issue 5 | Pages 677 - 683
1 May 2014
Greenberg A Berenstein Weyel T Sosna J Applbaum J Peyser A

Osteoid osteoma is treated primarily by radiofrequency (RF) ablation. However, there is little information about the distribution of heat in bone during the procedure and its safety. We constructed a model of osteoid osteoma to assess the distribution of heat in bone and to define the margins of safety for ablation. Cavities were drilled in cadaver bovine bones and filled with a liver homogenate to simulate the tumour matrix. Temperature-sensing probes were placed in the bone in a radial fashion away from the cavities. RF ablation was performed 107 times in tumours < 10 mm in diameter (72 of which were in cortical bone, 35 in cancellous bone), and 41 times in cortical bone with models > 10 mm in diameter. Significantly higher temperatures were found in cancellous bone than in cortical bone (p <  0.05). For lesions up to 10 mm in diameter, in both bone types, the temperature varied directly with the size of the tumour (p < 0.05), and inversely with the distance from it. Tumours of > 10 mm in diameter showed a trend similar to those of smaller lesions. No temperature rise was seen beyond 12 mm from the edge of a cortical tumour of any size. Formulae were developed to predict the expected temperature in the bone during ablation.

Cite this article: Bone Joint J 2014; 96-B:677–83


The Bone & Joint Journal
Vol. 96-B, Issue 3 | Pages 399 - 405
1 Mar 2014
Zang J Guo W Yang Y Xie L

We report our early experience with the use of a new prosthesis, the Modular Hemipelvic Prosthesis II, for reconstruction of the hemipelvis after resection of a primary malignant peri-acetabular tumour involving the sacroiliac joint.

We retrospectively reviewed the outcome of 17 patients who had undergone resection of a pelvic tumour and reconstruction with this prosthesis between July 2002 and July 2010.

One patient had a type I+II+III+IV resection (ilium + peri-acetabulum + pubis/ischium + sacrum) and 16 had a type I+II+IV resection (ilium + acetabulum + sacrum). The outcome was assessed at a mean follow-up of 33 months (15 to 59). One patient was alive with disease, 11 were alive without disease and five had died of disease. The overall five-year survival rate was 62.4%. Six patients had a local recurrence. The mean Musculoskeletal Tumour Society score was 58% (33 to 77). Deep infection occurred in two patients, problems with wound healing in five and dislocation in one.

For patients with a primary malignant peri-acetabular sarcoma involving the sacroiliac joint, we believe that this new prosthesis is a viable option for reconstruction of the bony defect left following resection of the tumour. It results in a satisfactory functional outcome with an acceptable rate of complications.

Cite this article: Bone Joint J 2014;96-B:399–405.


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1562 - 1569
1 Nov 2013
Al-Hadithy N Dodds AL Akhtar KSN Gupte CM

Recent reports have suggested an increase in the number of anterior cruciate ligament (ACL) injuries in children, although their true incidence is unknown.

The prognosis of the ACL-deficient knee in young active individuals is poor because of secondary meniscal tears, persistent instability and early-onset osteoarthritis. The aim of surgical reconstruction is to provide stability while avoiding physeal injury. Techniques of reconstruction include transphyseal, extraphyseal or partial physeal sparing procedures.

In this paper we review the management of ACL tears in skeletally immature patients.

Cite this article: Bone Joint J 2013;95-B:1562–9.


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 838 - 845
1 Jun 2013
Oliveira VC van der Heijden L van der Geest ICM Campanacci DA Gibbons CLMH van de Sande MAJ Dijkstra PDS

Giant cell tumours (GCTs) of the small bones of the hands and feet are rare. Small case series have been published but there is no consensus about ideal treatment. We performed a systematic review, initially screening 775 titles, and included 12 papers comprising 91 patients with GCT of the small bones of the hands and feet. The rate of recurrence across these publications was found to be 72% (18 of 25) in those treated with isolated curettage, 13% (2 of 15) in those treated with curettage plus adjuvants, 15% (6 of 41) in those treated by resection and 10% (1 of 10) in those treated by amputation.

We then retrospectively analysed 30 patients treated for GCT of the small bones of the hands and feet between 1987 and 2010 in five specialised centres. The primary treatment was curettage in six, curettage with adjuvants (phenol or liquid nitrogen with or without polymethylmethacrylate (PMMA)) in 18 and resection in six. We evaluated the rate of complications and recurrence as well as the factors that influenced their functional outcome.

At a mean follow-up of 7.9 years (2 to 26) the rate of recurrence was 50% (n = 3) in those patients treated with isolated curettage, 22% (n = 4) in those treated with curettage plus adjuvants and 17% (n = 1) in those treated with resection (p = 0.404). The only complication was pain in one patient, which resolved after surgical removal of remnants of PMMA. We could not identify any individual factors associated with a higher rate of complications or recurrence. The mean post-operative Musculoskeletal Tumor Society scores were slightly higher after intra-lesional treatment including isolated curettage and curettage plus adjuvants (29 (20 to 30)) compared with resection (25 (15 to 30)) (p = 0.091). Repeated curettage with adjuvants eventually resulted in the cure for all patients and is therefore a reasonable treatment for both primary and recurrent GCT of the small bones of the hands and feet.

Cite this article: Bone Joint J 2013;95-B:838–45.


The Bone & Joint Journal
Vol. 95-B, Issue 1 | Pages 20 - 22
1 Jan 2013
Kyriacou S Pastides PS Singh VK Jeyaseelan L Sinisi M Fox M

The purpose of this study was to establish whether exploration and neurolysis is an effective method of treating neuropathic pain in patients with a sciatic nerve palsy after total hip replacement (THR). A total of 56 patients who had undergone this surgery at our hospital between September 1999 and September 2010 were retrospectively identified. There were 42 women and 14 men with a mean age at exploration of 61.2 years (28 to 80). The sciatic nerve palsy had been sustained by 46 of the patients during a primary THR, five during a revision THR and five patients during hip resurfacing. The mean pre-operative visual analogue scale (VAS) pain score was 7.59 (2 to 10), the mean post-operative VAS was 3.77 (0 to 10), with a resulting mean improvement of 3.82 (0 to 10). The pre- and post-neurolysis VAS scores were significantly different (p < 0.001). Based on the findings of our study, we recommend this form of surgery over conservative management in patients with neuropathic pain associated with a sciatic nerve palsy after THR.

Cite this article: Bone Joint J 2013;95-B:20–2.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 36 - 41
1 Nov 2012
Aderinto J Lulu OB Backstein DJ Safir O Gross AE

Eighteen hip fusions were converted to total hip replacements. A constrained acetabular liner was used in three hips. Mean follow up was five years (two to 15). Two (11%) hips failed, requiring revision surgery and two patients (11%) had injury to the peroneal nerve. Heterotopic ossification developed in seven (39%) hips, in one case resulting in joint ankylosis. No hips dislocated.

Conversion of hip fusion to hip replacement carries an increased risk of heterotopic ossification and neurological injury. We advise prophylaxis against heterotropic ossification. When there is concern about hip stability we suggest that the use of a constrained acetabular liner is considered. Despite the potential for complications, this procedure had a high success rate and was effective in restoring hip function.


Bone & Joint 360
Vol. 1, Issue 5 | Pages 21 - 24
1 Oct 2012

The October 2012 Spine Roundup360 looks at: a Japanese questionnaire at work in Iran; curve progression in degenerative lumbar scoliosis; the cause of foot drop; the issue of avoiding the spinal cord at scoliosis surgery; ballistic injuries to the cervical spine; minimally invasive oblique lumbar interbody fusion; readmission rates after spinal surgery; clinical complications and the severely injured cervical spine; and stabilising the thoracolumbar burst fracture.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 4 | Pages 446 - 453
1 Apr 2012
Moran CG Forward DP

There have been many advances in the resuscitation and early management of patients with severe injuries during the last decade. These have come about as a result of the reorganisation of civilian trauma services in countries such as Germany, Australia and the United States, where the development of trauma systems has allowed a concentration of expertise and research. The continuing conflicts in the Middle East have also generated a significant increase in expertise in the management of severe injuries, and soldiers now survive injuries that would have been fatal in previous wars. This military experience is being translated into civilian practice.

The aim of this paper is to give orthopaedic surgeons a practical, evidence-based guide to the current management of patients with severe, multiple injuries. It must be emphasised that this depends upon the expertise, experience and facilities available within the local health-care system, and that the proposed guidelines will inevitably have to be adapted to suit the local resources.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 4 | Pages 555 - 557
1 Apr 2011
Marchese M Sinisi M Anand P Di Mascio L Humphrey J

A 60-year-old man developed severe neuropathic pain and foot-drop in his left leg following resurfacing arthroplasty of the left hip. The pain was refractory to all analgesics for 16 months. At exploration, a PDS suture was found passing through the sciatic nerve at several points over 6 cm and terminating in a large knot. After release of the suture and neurolysis there was dramatic and rapid improvement of the neuropathic pain and of motor function.

This case represents the human equivalent of previously described nerve ligation in an animal model of neuropathic pain. It emphasises that when neuropathic pain is present after an operation, the nerve related to the symptoms must be inspected, and that removal of a suture or irritant may lead to relief of pain, even after many months.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 11 | Pages 1541 - 1544
1 Nov 2009
Hosono N Miwa T Mukai Y Takenaka S Makino T Fuji T

Using the transverse processes of fresh porcine lumbar spines as an experimental model we evaluated the heat generated by a rotating burr of a high-speed drill in cutting the bone. The temperature at the drilled site reached 174°C with a diamond burr and 77°C with a steel burr. With water irrigation at a flow rate of 540 ml/hr an effective reduction in the temperature was achieved whereas irrigation with water at 180 ml/hr was much less effective. There was a significant negative correlation between the thickness of the residual bone and the temperature measured at its undersurface adjacent to the drilling site (p < 0.001).

Our data suggest that tissues neighbouring the drilled bone, especially nerve roots, can be damaged by the heat generated from the tip of a high-speed drill. Nerve-root palsy, one of the most common complications of cervical spinal surgery, may be caused by thermal damage to nerve roots arising in this manner.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 5 | Pages 674 - 676
1 May 2008
May O Girard J Hurtevent JF Migaud H

Delayed sciatic nerve palsy is uncommon after primary hip replacement. Two kinds of sciatic palsy have been reported with regard to the time of onset: early palsy related to wound haematoma or lumbosacral nerve elongation which occurs between surgery and 18 days, is more frequent than delayed palsy, occurring between 10 and 32 months, which is usually caused by cement extrusion or heat produced by cement polymerisation.

We present two cases of delayed, transient sciatic nerve palsy arising at three weeks and four months after primary cementless arthroplasty, respectively, without haematoma and with a normal lumbar spine. These palsies were possibly caused by excessive tension from minor limb lengthening of 2 cm to 4 cm required to achieve leg-length equality. As the initial symptoms were limited to calf pain and mild numbness in the foot, surgeons should be aware of this mode of onset, particularly when it is delayed after hip replacement. Both patients recovered fully by 12 months after surgery so we did not undertake surgical exploration of the nerve in either patient.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1421 - 1426
1 Nov 2007
Pape H Giannoudis P

This paper summarises the current knowledge on the effects of medullary reaming of long-bone fractures. Following a review of intramedullary vascular physiology, the consequences for vascularity, the autograft effects, the generation of heat, and fat embolism are outlined. Also, alternative reaming techniques are described.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 11 | Pages 1465 - 1467
1 Nov 2005
Butt AJ McCarthy T Kelly IP Glynn T McCoy G

Sciatic nerve palsy is a recognised complication of primary total hip replacement. In our unit this complication was rare with an incidence of < 0.2% in the past ten years. We describe six cases of sciatic nerve palsy occurring in 355 consecutive primary total hip replacements (incidence 1.69%). Each of these palsies was caused by post-operative haematoma in the region of the sciatic nerve.

Cases, which were recognised early and surgically-evacuated promptly, showed earlier and more complete recovery. Those patients for whom the diagnosis was delayed, and who were therefore managed expectantly, showed little or no recovery. Unexpected pain and significant swelling in the buttock, as well as signs of sciatic nerve irritation, suggest the presence of haematoma in the region of the sciatic nerve.

It is, therefore, of prime importance to be vigilant for the features of a sciatic nerve palsy in the early post-operative period as, when recognised and treated early, the injury to the sciatic nerve may be reversed.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 5 | Pages 716 - 719
1 May 2005
Davies R Holt N Nayagam S

Two protocols for the operative technique and care of the pin-site with external fixation were compared prospectively. There was a total of 120 patients with 46 in group A and 74 in group B. Infection was defined as an episode of pain or inflammation at a pin site, accompanied by a discharge which was either positive on bacterial culture or responded to a course of antibiotics. Patients in group B had a lower proportion of infected pin sites (p = 0.003) and the time to the first episode of infection was longer (p < 0.001). The risk of pin-site infection is lower if attention is paid to avoiding thermal injury and local formation of haematoma during surgery and if after-care includes the use of an alcoholic antiseptic and occlusive pressure dressings


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 320 - 323
1 Mar 2005
Little CP Ruiz AL Harding IJ McLardy-Smith P Gundle R Murray DW Athanasou NA

We present the histological findings of bone retrieved from beneath the femoral components of failed metal-on-metal hip resurfacing arthroplasties. Of a total of 377 patients who underwent resurfacing arthroplasty, 13 required revision; for fracture of the femoral neck in eight, loosening of a component in three and for other reasons in two. None of these cases had shown histological evidence of osteonecrosis in the femoral bone at the time of the initial implantation.

Bone from the remnant of the femoral head showed changes of osteonecrosis in all but one case at revision. In two cases of fracture which occurred within a week of implantation, the changes were compatible with early necrosis of the edge of the fracture. In the remaining six fractures, there were changes of established osteonecrosis. In all but one of the non-fracture cases, patchy osteonecrosis was seen.

We conclude that histological evidence of osteonecrosis is a common finding in failed resurfaced hips. Given that osteonecrosis is extensive in resurfaced femoral heads which fail by fracture, it is likely to play a role in the causation of these fractures.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 8 | Pages 1214 - 1219
1 Nov 2004
Jafri AA Green SM Partington PF McCaskie AW Muller SD

Fatigue fractures which originate at stress-concentrating voids located at the implant-cement interface are a potential cause of septic loosening of cemented femoral components. Heating of the component to 44°C is known to reduce the porosity of the cement-prosthesis interface. The temperature of the cement-bone interface was recorded intra-operatively as 32.3°C. A simulated femoral model was devised to study the effect of heating of the component on the implant-cement interface. Heating of the implant and vacuum mixing have a synergistic effect on the porosity of the implant-cement interface, and heating also reverses the gradients of microhardness in the mantle. Heating of the implant also reduces porosity at the interface depending on the temperature. A minimum difference in temperature between the implant and the bone of 3°C was required to produce this effect. The optimal difference was 7°C, representing a balance between maximal reduction of porosity and an increased risk of thermal injury. Using contemporary cementing techniques, heating the implant to 40°C is recommended to produce an optimum effect


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 3 | Pages 357 - 362
1 May 1996
Natali C Ingle P Dowell J

We studied the various drill bits available for engineering purposes, and compared them with standard orthopaedic drill bits, using continuous temperature recording at 0.5 mm, 1.0 mm and 1.5 mm from the edge of a 2.5 mm hole as it was drilled in fresh cadaver human tibia. We found that some commercially available drill bits performed better than their orthopaedic equivalents, producing significantly less thermal injury to the surrounding bone and halving the force required for cortical penetration. Our work suggests that the optimal bit for orthopaedic purposes should have a split point and a quick helix. Theoretical knowledge of cutting technology predicts that the addition of a parabolic flute will further reduce thermal damage. Further work is being done on other drill sizes used in orthopaedic practice and on new custom-designed bits


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 5 | Pages 770 - 774
1 Nov 1986
Mjoberg B Selvik G Hansson L Rosenqvist R Onnerfalt R

Twenty patients were examined by standard radiography and roentgen stereophotogrammetric analysis (RSA) during a two-year period after total hip arthroplasty. Eleven of the acetabular components migrated cranially and three femoral components migrated distally. This migration was most rapid during the first four months after operation. Our findings support the possibility that mechanical loosening is initiated by thermal injury during polymerisation of the cement; the less frequent migration of the metallic femoral component compared with the polyethylene acetabular component may be because the metal acts as a heat sink. Standard radiographs were inadequate for assessment of early mechanical loosening, whereas RSA could reveal migration within four months of the arthroplasty