Advertisement for orthosearch.org.uk
Results 1 - 37 of 37
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1223 - 1230
1 Nov 2024
Dugdale EM Uvodich ME Pagnano MW Berry DJ Abdel MP Bedard NA

Aims

The prevalence of obesity is increasing substantially around the world. Elevated BMI increases the risk of complications following total hip arthroplasty (THA). We sought to evaluate trends in BMI and complication rates of obese patients undergoing primary THA over the last 30 years.

Methods

Through our institutional total joint registry, we identified 15,455 primary THAs performed for osteoarthritis from 1990 to 2019. Patients were categorized according to the World Health Organization (WHO) obesity classification and groups were trended over time. Cox proportional hazards regression analysis controlling for confounders was used to investigate the association between year of surgery and two-year risk of any reoperation, any revision, dislocation, periprosthetic joint infection (PJI), venous thromboembolism (VTE), and periprosthetic fracture. Regression was stratified by three separate groups: non-obese; WHO Class I and Class II (BMI 30 to 39 kg/m2); and WHO Class III patients (BMI ≥ 40 kg/m2).


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 66 - 73
1 May 2024
Chaudhry F Daud A Greenberg A Braunstein D Safir OA Gross AE Kuzyk PR

Aims

Pelvic discontinuity is a challenging acetabular defect without a consensus on surgical management. Cup-cage reconstruction is an increasingly used treatment strategy. The present study evaluated implant survival, clinical and radiological outcomes, and complications associated with the cup-cage construct.

Methods

We included 53 cup-cage construct (51 patients) implants used for hip revision procedures for pelvic discontinuity between January 2003 and January 2022 in this retrospective review. Mean age at surgery was 71.8 years (50.0 to 92.0; SD 10.3), 43/53 (81.1%) were female, and mean follow-up was 6.4 years (0.02 to 20.0; SD 4.6). Patients were implanted with a Trabecular Metal Revision Shell with either a ZCA cage (n = 12) or a TMARS cage (n = 40, all Zimmer Biomet). Pelvic discontinuity was diagnosed on preoperative radiographs and/or intraoperatively. Kaplan-Meier survival analysis was performed, with failure defined as revision of the cup-cage reconstruction.


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 359 - 364
1 Apr 2024
Özdemir E de Lange B Buckens CFM Rijnen WHC Visser J

Aims

To investigate the extent of bone development around the scaffold of custom triflange acetabular components (CTACs) over time.

Methods

We performed a single-centre historical prospective cohort study, including all patients with revision THA using the aMace CTAC between January 2017 and March 2021. A total of 18 patients (18 CTACs) were included. Models of the hemipelvis and the scaffold component of the CTACs were created by segmentation of CT scans. The CT scans were performed immediately postoperatively and at least one year after surgery. The amount of bone in contact with the scaffold was analyzed at both times, and the difference was calculated.


Bone & Joint Open
Vol. 4, Issue 11 | Pages 853 - 858
10 Nov 2023
Subbiah Ponniah H Logishetty K Edwards TC Singer GC

Aims

Metal-on-metal hip resurfacing (MoM-HR) has seen decreased usage due to safety and longevity concerns. Joint registries have highlighted the risks in females, smaller hips, and hip dysplasia. This study aimed to identify if reported risk factors are linked to revision in a long-term follow-up of MoM-HR performed by a non-designer surgeon.

Methods

A retrospective review of consecutive MoM hip arthroplasties (MoM-HRAs) using Birmingham Hip Resurfacing was conducted. Data on procedure side, indication, implant sizes and orientation, highest blood cobalt and chromium ion concentrations, and all-cause revision were collected from local and UK National Joint Registry records.


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 775 - 782
1 Jul 2023
Koper MC Spek RWA Reijman M van Es EM Baart SJ Verhaar JAN Bos PK

Aims

The aims of this study were to determine if an increasing serum cobalt (Co) and/or chromium (Cr) concentration is correlated with a decreasing Harris Hip Score (HHS) and Hip disability and Osteoarthritis Outcome Score (HOOS) in patients who received the Articular Surface Replacement (ASR) hip resurfacing arthroplasty (HRA), and to evaluate the ten-year revision rate and show if sex, inclination angle, and Co level influenced the revision rate.

Methods

A total of 62 patients with an ASR-HRA were included and monitored yearly postoperatively. At follow-up, serum Co and Cr levels were measured and the HHS and the HOOS were scored. In addition, preoperative patient and implant variables and the need for revision surgery were recorded. We used a linear mixed model to relate the serum Co and Cr levels to different patient-reported outcome measures (PROMs). For the survival analyses we used the Kaplan-Meier and Cox regression model.


Bone & Joint Open
Vol. 3, Issue 11 | Pages 867 - 876
10 Nov 2022
Winther SS Petersen M Yilmaz M Kaltoft NS Stürup J Winther NS

Aims

Pelvic discontinuity is a rare but increasingly common complication of total hip arthroplasty (THA). This single-centre study evaluated the performance of custom-made triflange acetabular components in acetabular reconstruction with pelvic discontinuity by determining: 1) revision and overall implant survival rates; 2) discontinuity healing rate; and 3) Harris Hip Score (HHS).

Methods

Retrospectively collected data of 38 patients (39 hips) with pelvic discontinuity treated with revision THA using a custom-made triflange acetabular component were analyzed. Minimum follow-up was two years (mean 5.1 years (2 to 11)).


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 820 - 825
1 Jul 2022
Dhawan R Baré JV Shimmin A

Aims

Adverse spinal motion or balance (spine mobility) and adverse pelvic mobility, in combination, are often referred to as adverse spinopelvic mobility (SPM). A stiff lumbar spine, large posterior standing pelvic tilt, and severe sagittal spinal deformity have been identified as risk factors for increased hip instability. Adverse SPM can create functional malposition of the acetabular components and hence is an instability risk. Adverse pelvic mobility is often, but not always, associated with abnormal spinal motion parameters. Dislocation rates for dual-mobility articulations (DMAs) have been reported to be between 0% and 1.1%. The aim of this study was to determine the early survivorship from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) of patients with adverse SPM who received a DMA.

Methods

A multicentre study was performed using data from 227 patients undergoing primary total hip arthroplasty (THA), enrolled consecutively. All the patients who had one or more adverse spine or pelvic mobility parameter had a DMA inserted at the time of their surgery. The mean age was 76 years (22 to 93) and 63% were female (n = 145). At a mean of 14 months (5 to 31) postoperatively, the AOANJRR was analyzed for follow-up information. Reasons for revision and types of revision were identified.


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 212 - 220
1 Feb 2022
Fishley WG Selvaratnam V Whitehouse SL Kassam AM Petheram TG

Aims. Femoral cement-in-cement revision is a well described technique to reduce morbidity and complications in hip revision surgery. Traditional techniques for septic revision of hip arthroplasty necessitate removal of all bone cement from the femur. In our two centres, we have been using a cement-in-cement technique, leaving the distal femoral bone cement in selected patients for septic hip revision surgery, both for single and the first of two-stage revision procedures. A prerequisite for adoption of this technique is that the surgeon considers the cement mantle to be intimately fixed to bone without an intervening membrane between cement and host bone. We aim to report our experience for this technique. Methods. We have analyzed patients undergoing this cement-in-cement technique for femoral revision in infection, and present a consecutive series of 89 patients. Follow-up was undertaken at a mean of 56.5 months (24.0 to 134.7) for the surviving cases. Results. Seven patients (7.9%) required further revision for infection. Ten patients died of causes unrelated to their infection before their two-year review (mean 5.9 months; 0.9 to 18.6). One patient was lost to follow-up at five months after surgery, and two patients died of causes unrelated to their hip shortly after their two-year review was due without attending. Of the remaining patients, 69 remained infection-free at final review. Radiological review confirms the mechanical success of the procedure as previously described in aseptic revision, and postoperative Oxford Hip Scores suggest satisfactory functional outcomes. Conclusion. In conclusion, we found that retaining a well-fixed femoral cement mantle in the presence of infection and undertaking a cement-in-cement revision was successful in 82 of the patients (92.1%) in our series of 89, both in terms of eradication of infection and component fixation. These results are comparable to other more invasive techniques and offer significant potential benefits to the patient. Cite this article: Bone Joint J 2022;104-B(2):212–220


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 59 - 67
1 Jan 2022
Kingsbury SR Smith LK Shuweihdi F West R Czoski Murray C Conaghan PG Stone MH

Aims

The aim of this study was to conduct a cross-sectional, observational cohort study of patients presenting for revision of a total hip, or total or unicompartmental knee arthroplasty, to understand current routes to revision surgery and explore differences in symptoms, healthcare use, reason for revision, and the revision surgery (surgical time, components, length of stay) between patients having regular follow-up and those without.

Methods

Data were collected from participants and medical records for the 12 months prior to revision. Patients with previous revision, metal-on-metal articulations, or hip hemiarthroplasty were excluded. Participants were retrospectively classified as ‘Planned’ or ‘Unplanned’ revision. Multilevel regression and propensity score matching were used to compare the two groups.


Bone & Joint 360
Vol. 10, Issue 2 | Pages 21 - 23
1 Apr 2021


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 492 - 499
1 Mar 2021
Garcia-Rey E Saldaña L Garcia-Cimbrelo E

Aims

Bone stock restoration of acetabular bone defects using impaction bone grafting (IBG) in total hip arthroplasty may facilitate future re-revision in the event of failure of the reconstruction. We hypothesized that the acetabular bone defect during re-revision surgery after IBG was smaller than during the previous revision surgery. The clinical and radiological results of re-revisions with repeated use of IBG were also analyzed.

Methods

In a series of 382 acetabular revisions using IBG and a cemented component, 45 hips (45 patients) that had failed due to aseptic loosening were re-revised between 1992 and 2016. Acetabular bone defects graded according to Paprosky during the first and the re-revision surgery were compared. Clinical and radiological findings were analyzed over time. Survival analysis was performed using a competing risk analysis.


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 398 - 404
1 Feb 2021
Christ AB Fujiwara T Yakoub MA Healey JH

Aims

We have evaluated the survivorship, outcomes, and failures of an interlocking, reconstruction-mode stem-sideplate implant used to preserve the native hip joint and achieve proximal fixation when there is little residual femur during large endoprosthetic reconstruction of the distal femur.

Methods

A total of 14 patients underwent primary or revision reconstruction of a large femoral defect with a short remaining proximal femur using an interlocking, reconstruction-mode stem-sideplate for fixation after oncological distal femoral and diaphyseal resections. The implant was attached to a standard endoprosthetic reconstruction system. The implant was attached to a standard endoprosthetic reconstruction system. None of the femoral revisions were amenable to standard cemented or uncemented stem fixation. Patient and disease characteristics, surgical history, final ambulatory status, and Musculoskeletal Tumor Society (MSTS) score were recorded. The percentage of proximal femur remaining was calculated from follow-up radiographs.


Bone & Joint 360
Vol. 9, Issue 6 | Pages 15 - 18
1 Dec 2020


The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1319 - 1323
3 Oct 2020
Khatun F Gill DF Atrey A Porteous M

Aims

We present the results, in terms of survival, clinical outcome, and radiological appearance at 20 years, in a cohort of 225 cemented Exeter Universal femoral components (Stryker, Newbury, UK) implanted in 207 patients, at a district general hospital.

Methods

All patients in this study had a total hip arthroplasty (THA) using an Exeter Universal femoral component with a cemented (n = 215) or cementless (n = 10) acetabular component. Clinical and radiological data were collected prospectively at one year, five years, and every five years thereafter. Patients lost to radiological and clinical follow-up (five) were cross-referenced with National Joint Registry (NJR) data and general practitioner (GP) records to assess whether they had undergone revision for any reason.


Bone & Joint Open
Vol. 1, Issue 6 | Pages 198 - 202
6 Jun 2020
Lewis PM Waddell JP

It is unusual, if not unique, for three major research papers concerned with the management of the fractured neck of femur (FNOF) to be published in a short period of time, each describing large prospective randomized clinical trials. These studies were conducted in up to 17 countries worldwide, involving up to 80 surgical centers and include large numbers of patients (up to 2,900) with FNOF. Each article investigated common clinical dilemmas; the first paper comparing total hip arthroplasty versus hemiarthroplasty for FNOF, the second as to whether ‘fast track’ care offers improved clinical outcomes and the third, compares sliding hip with multiple cancellous hip screws. Each paper has been deemed of sufficient quality and importance to warrant publication in The Lancet or the New England Journal of Medicine. Although ‘premier’ journals, they only occationally contain orthopaedic studies and thus may not be routinely read by the busy orthopaedic/surgical clinician of any grade. It is therefore our intention with this present article to accurately summarize and combine the results of all three papers, presenting, in our opinion, the most important clinically relevant facts.

Cite this article: Bone Joint Open 2020;1-6:198–202.


Bone & Joint Research
Vol. 9, Issue 5 | Pages 202 - 210
1 May 2020
Trotter AJ Dean R Whitehouse CE Mikalsen J Hill C Brunton-Sim R Kay GL Shakokani M Durst AZE Wain J McNamara I O’Grady J

Aims

This pilot study tested the performance of a rapid assay for diagnosing prosthetic joint infection (PJI), which measures synovial fluid calprotectin from total hip and knee revision patients.

Methods

A convenience series of 69 synovial fluid samples from revision patients at the Norfolk and Norwich University Hospital were collected intraoperatively (52 hips, 17 knees) and frozen. Synovial fluid calprotectin was measured retrospectively using a new commercially available lateral flow assay for PJI diagnosis (Lyfstone AS) and compared to International Consensus Meeting (ICM) 2018 criteria and clinical case review (ICM-CR) gold standards.


Bone & Joint Research
Vol. 8, Issue 4 | Pages 179 - 188
1 Apr 2019
Chen M Chang C Yang L Hsieh P Shih H Ueng SWN Chang Y

Objectives. Prosthetic joint infection (PJI) diagnosis is a major challenge in orthopaedics, and no reliable parameters have been established for accurate, preoperative predictions in the differential diagnosis of aseptic loosening or PJI. This study surveyed factors in synovial fluid (SF) for improving PJI diagnosis. Methods. We enrolled 48 patients (including 39 PJI and nine aseptic loosening cases) who required knee/hip revision surgery between January 2016 and December 2017. The PJI diagnosis was established according to the Musculoskeletal Infection Society (MSIS) criteria. SF was used to survey factors by protein array and enzyme-linked immunosorbent assay to compare protein expression patterns in SF among three groups (aseptic loosening and first- and second-stage surgery). We compared routine clinical test data, such as C-reactive protein level and leucocyte number, with potential biomarker data to assess the diagnostic ability for PJI within the same patient groups. Results. Cut-off values of 1473 pg/ml, 359 pg/ml, and 8.45 pg/ml were established for interleukin (IL)-16, IL-18, and cysteine-rich with EGF-like domains 2 (CRELD2), respectively. Receiver operating characteristic curve analysis showed that these factors exhibited an accuracy of 1 as predictors of PJI. These factors represent potential biomarkers for decisions associated with prosthesis reimplantation based on their ability to return to baseline values following the completion of debridement. Conclusion. IL-16, IL-18, and CRELD2 were found to be potential biomarkers for PJI diagnosis, with SF tests outperforming blood tests in accuracy. These factors could be useful for assessing successful debridement based on their ability to return to baseline values following the completion of debridement. Cite this article: M-F. Chen, C-H. Chang, L-Y. Yang, P-H. Hsieh, H-N. Shih, S. W. N. Ueng, Y. Chang. Synovial fluid interleukin-16, interleukin-18, and CRELD2 as novel biomarkers of prosthetic joint infections. Bone Joint Res 2019;8:179–188. DOI: 10.1302/2046-3758.84.BJR-2018-0291.R1


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1609 - 1617
1 Dec 2018
Malhas AM Granville-Chapman J Robinson PM Brookes-Fazakerley S Walton M Monga P Bale S Trail I

Aims

We present our experience of using a metal-backed prosthesis and autologous bone graft to treat gross glenoid bone deficiency.

Patients and Methods

A prospective cohort study of the first 45 shoulder arthroplasties using the SMR Axioma Trabecular Titanium (TT) metal-backed glenoid with autologous bone graft. Between May 2013 and December 2014, 45 shoulder arthroplasties were carried out in 44 patients with a mean age of 64 years (35 to 89). The indications were 23 complex primary arthroplasties, 12 to revise a hemiarthroplasty or resurfacing, five for aseptic loosening of the glenoid, and five for infection.


Bone & Joint 360
Vol. 7, Issue 4 | Pages 12 - 15
1 Aug 2018


Bone & Joint 360
Vol. 6, Issue 3 | Pages 10 - 12
1 Jun 2017


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 592 - 600
1 May 2017
Matharu GS Nandra RS Berryman F Judge A Pynsent PB Dunlop DJ

Aims

To determine ten-year failure rates following 36 mm metal-on-metal (MoM) Pinnacle total hip arthroplasty (THA), and identify predictors of failure.

Patients and Methods

We retrospectively assessed a single-centre cohort of 569 primary 36 mm MoM Pinnacle THAs (all Corail stems) followed up since 2012 according to Medicines and Healthcare Products Regulation Agency recommendations. All-cause failure rates (all-cause revision, and non-revised cross-sectional imaging failures) were calculated, with predictors for failure identified using multivariable Cox regression.


The Bone & Joint Journal
Vol. 98-B, Issue 7 | Pages 901 - 909
1 Jul 2016
Amstutz HC Le Duff MJ

Aims. Hip resurfacing arthroplasty (HRA) is an alternative to conventional total hip arthroplasty for patients with osteonecrosis (ON) of the femoral head. Our aim was to report the long-term outcome of HRA, which is not currently known. Patients and Methods. Long-term survivorship, clinical scores and radiographic results for 82 patients (99 hips) treated with HRA for ON over a period of 18 years were reviewed retrospectively. The mean age of the 67 men and 15 women at the time of surgery was 40.8 years (14 to 64). Patients were resurfaced regardless of the size of the osteonecrotic lesion. Results. The mean clinical follow-up was 10.8 years (2 to 18). The mean University of California, Los Angeles hip scores at the last follow-up were 9.3, 9.4, 9.2 and 6.8 for pain, walking, function and activity, respectively. A total of six hips underwent revision surgery, four for loosening of the femoral component and two for loosening of the acetabular component. Using any revision as an end point, the 15-year Kaplan-Meier survivorship was 90.3%. There were no wear-related failures. There were no femoral failures among the hips reconstructed with a cemented metaphyseal stem. A total of five hips showed narrowing of the femoral neck; all stabilised and remain asymptomatic, 21 showed signs of femoral neck impingement. Conclusion. To our knowledge, this is the first report of a series of HRA performed for ON with 15-year survivorship. Our data confirm that patients with advanced stages of ON of the femoral head are excellent candidates for HRA. Cite this article: Bone Joint J 2016;98-B:901–9


The Bone & Joint Journal
Vol. 98-B, Issue 2 | Pages 179 - 186
1 Feb 2016
Berber R Skinner J Board T Kendoff D Eskelinen A Kwon Y Padgett DE Hart A

Aims

There are many guidelines that help direct the management of patients with metal-on-metal (MOM) hip arthroplasties. We have undertaken a study to compare the management of patients with MOM hip arthroplasties in different countries.

Methods

Six international tertiary referral orthopaedic centres were invited to participate by organising a multi-disciplinary team (MDT) meeting, consisting of two or more revision hip arthroplasty surgeons and a musculoskeletal radiologist. A full clinical dataset including history, blood tests and imaging for ten patients was sent to each unit, for discussion and treatment planning. Differences in the interpretation of findings, management decisions and rationale for decisions were compared using quantitative and qualitative methods.


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1600 - 1609
1 Dec 2014
Matharu GS Pynsent PB Sumathi VP Mittal S Buckley CD Dunlop DJ Revell PA Revell MP

We undertook a retrospective cohort study to determine clinical outcomes following the revision of metal-on-metal (MoM) hip replacements for adverse reaction to metal debris (ARMD), and to identify predictors of time to revision and outcomes following revision. Between 1998 and 2012 a total of 64 MoM hips (mean age at revision of 57.8 years; 46 (72%) female; 46 (72%) hip resurfacings and 18 (28%) total hip replacements) were revised for ARMD at one specialist centre. At a mean follow-up of 4.5 years (1.0 to 14.6) from revision for ARMD there were 13 hips (20.3%) with post-operative complications and eight (12.5%) requiring re-revision.

The Kaplan–Meier five-year survival rate for ARMD revision was 87.9% (95% confidence interval 78.9 to 98.0; 19 hips at risk). Excluding re-revisions, the median absolute Oxford hip score (OHS) following ARMD revision using the percentage method (0% best outcome and 100% worst outcome) was 18.8% (interquartile range (IQR) 7.8% to 48.3%), which is equivalent to 39/48 (IQR 24.8/48 to 44.3/48) when using the modified OHS. Histopathological response did not affect time to revision for ARMD (p = 0.334) or the subsequent risk of re-revision (p = 0.879). Similarly, the presence or absence of a contralateral MoM hip bearing did not affect time to revision for ARMD (p = 0.066) or the subsequent risk of re-revision (p = 0.178).

Patients revised to MoM bearings had higher rates of re-revision (five of 16 MoM hips re-revised; p = 0.046), but those not requiring re-revision had good functional results (median absolute OHS 14.6% or 41.0/48). Short-term morbidity following revision for ARMD was comparable with previous reports. Caution should be exercised when choosing bearing surfaces for ARMD revisions.

Cite this article: Bone Joint J 2014;96-B:1600–9.


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 56 - 59
1 Nov 2014
Konan S Garbuz DS Masri BA Duncan CP

Non-modular tapered fluted, titanium stems are available for use in femoral revision. The combination of taper and flutes on the stem provides axial and rotational stability, respectively. The material and surface properties of the stem promotes bone on-growth. If the surgeon is confident and reasonably experienced in the surgical use of this sort of design and the case is relatively straightforward, a non-modular design is effective. It also potentially reduces implant inventory, and circumvents the potential problems of taper junction corrosion and fatigue fracture. There are reports of excellent survival, good clinical and functional results and evidence of subsequent increase in proximal bone stock.

Cite this article: Bone Joint J 2014;96-B(11 Suppl A):56–9.


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1207 - 1213
1 Sep 2014
te Stroet MAJ Bronsema E Rijnen WHC Gardeniers JWM Schreurs BW

In this retrospective study, we investigated the results of revision total hip replacement (THR) using a cemented long-stemmed Exeter femoral component, with a minimum length of 205 mm in patients with extensive femoral bone defects. The study included 37 consecutive patients with a mean age of 76 years (39 to 93) and a mean follow-up of nine years (5 to 16). A total of 26 patients (70%) had a pre-operative Endo-Klinik score of 3 or 4. Impaction bone grafting was used in 24 patients (65%). At the time of evaluation, 22 patients (59%) were still alive and were evaluated clinically and radiologically. A total of 14 patients died during follow-up and their data were included until the time of their death. One reconstruction failed after five years and five months owing to recurrent dislocation: the hip was converted to an excision arthroplasty. Intra-operative fractures or fissures were encountered in nine patients (24%), but none occurred during impaction of the bone graft. Post-operative peri-prosthetic fractures occurred in two patients (5%); both were treated with plate fixation. At nine years, survival with the endpoint of all-cause re-revision was 96.3% (95% CI 76.4 to 99.5); including re-operations for any reason, it was 80.7% (95% CI 56.3 to 92.3%). There were no re-revisions for aseptic loosening.

The survival of long stem cemented femoral components following revision THR is satisfactory in a fragile population with extensive femoral defects.

Cite this article: Bone Joint J 2014; 96-B:1207–13.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 109 - 113
1 Nov 2013
Petrie J Sassoon A Haidukewych GJ

Pelvic discontinuity represents a rare but challenging problem for orthopaedic surgeons. It is most commonly encountered during revision total hip replacement, but can also result from an iatrogentic acetabular fracture during hip replacement. The general principles in management of pelvic discontinuity include restoration of the continuity between the ilium and the ischium, typically with some form of plating. Bone grafting is frequently required to restore pelvic bone stock. The acetabular component is then impacted, typically using an uncemented, trabecular metal component. Fixation with multiple supplemental screws is performed. For larger defects, a so-called ‘cup–cage’ reconstruction, or a custom triflange implant may be required. Pre-operative CT scanning can greatly assist in planning and evaluating the remaining bone stock available for bony ingrowth. Generally, good results have been reported for constructs that restore stability to the pelvis and allow some form of biologic ingrowth.

Cite this article: Bone Joint J 2013;95-B, Supple A:109–13.


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 777 - 781
1 Jun 2013
Abolghasemian M Drexler M Abdelbary H Sayedi H Backstein D Kuzyk P Safir O Gross AE

In this retrospective study we evaluated the proficiency of shelf autograft in the restoration of bone stock as part of primary total hip replacement (THR) for hip dysplasia, and in the results of revision arthroplasty after failure of the primary arthroplasty. Of 146 dysplastic hips treated by THR and a shelf graft, 43 were revised at an average of 156 months, 34 of which were suitable for this study (seven hips were excluded because of insufficient bone-stock data and two hips were excluded because allograft was used in the primary THR). The acetabular bone stock of the hips was assessed during revision surgery. The mean implant–bone contact was 58% (50% to 70%) at primary THR and 78% (40% to 100%) at the time of the revision, which was a significant improvement (p < 0.001). At primary THR all hips had had a segmental acetabular defect > 30%, whereas only five (15%) had significant segmental bone defects requiring structural support at the time of revision. In 15 hips (44%) no bone graft or metal augments were used during revision.

A total of 30 hips were eligible for the survival study. At a mean follow-up of 103 months (27 to 228), two aseptic and two septic failures had occurred. Kaplan-Meier survival analysis of the revision procedures demonstrated a ten-year survival rate of 93.3% (95% confidence interval (CI) 78 to 107) with clinical or radiological failure as the endpoint. The mean Oxford hip score was 38.7 (26 to 46) for non-revised cases at final follow-up.

Our results indicate that the use of shelf autografts during THR for dysplastic hips restores bone stock, contributing to the favourable survival of the revision arthroplasty should the primary procedure fail.

Cite this article: Bone Joint J 2013;95-B:777–81.


Bone & Joint Research
Vol. 1, Issue 10 | Pages 258 - 262
1 Oct 2012
Keurentjes JC Fiocco M Schreurs BW Pijls BG Nouta KA Nelissen RGHH

Objectives. The Kaplan-Meier estimation is widely used in orthopedics to calculate the probability of revision surgery. Using data from a long-term follow-up study, we aimed to assess the amount of bias introduced by the Kaplan-Meier estimator in a competing risk setting. Methods. We describe both the Kaplan-Meier estimator and the competing risk model, and explain why the competing risk model is a more appropriate approach to estimate the probability of revision surgery when patients die in a hip revision surgery cohort. In our study, a total of 62 acetabular revisions were performed. After a mean of 25 years, no patients were lost to follow-up, 13 patients had undergone revision surgery and 33 patients died of causes unrelated to their hip. Results. The Kaplan-Meier estimator overestimates the probability of revision surgery in our example by 3%, 11%, 28%, 32% and 60% at five, ten, 15, 20 and 25 years, respectively. As the cumulative incidence of the competing event increases over time, as does the amount of bias. Conclusions. Ignoring competing risks leads to biased estimations of the probability of revision surgery. In order to guide choosing the appropriate statistical analysis in future clinical studies, we propose a flowchart


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1194 - 1200
1 Sep 2011
Akiyama H Yamamoto K Tsukanaka M Kawanabe K Otsuka H So K Goto K Nakamura T

We retrospectively reviewed 40 hips in 36 patients who had undergone acetabular reconstruction using a titanium Kerboull-type acetabular reinforcement device with bone allografts between May 2001 and April 2006. Impacted bone allografts were used for the management of American Academy of Orthopaedic Surgeons Type II defects in 17 hips, and bulk bone allografts together with impacted allografts were used for the management of Type III defects in 23 hips. A total of five hips showed radiological failure at a mean follow-up of 6.7 years (4.5 to 9.3), two of which were infected. The mean pre-operative Merle d’Aubigné score was 10 (5 to 15) vs 13.6 (9 to 18) at the latest follow-up. The Kaplan-Meier survival rate at ten years, calculated using radiological failure or revision of the acetabular component for any reason as the endpoint, was 87% (95% confidence interval 76.3 to 97.7). A separate experimental analysis of the mechanical properties of the device and the load-displacement properties of bone grafts showed that a structurally hard allograft resected from femoral heads of patients with osteoarthritis should be preferentially used in any type of defect. If impacted bone allografts were used, a bone graft thickness of < 25 mm was acceptable in Type II defects.

This clinical study indicates that revision total hip replacement using the Kerboull-type acetabular reinforcement device with bone allografts yielded satisfactory mid-term results.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 3 | Pages 349 - 355
1 Mar 2010
Babis GC Sakellariou VI O’Connor MI Hanssen AD Sim FH

We report the use of an allograft prosthetic composite for reconstruction of the skeletal defect in complex revision total hip replacement for severe proximal femoral bone loss. Between 1986 and 1999, 72 patients (20 men, 52 women) with a mean age of 59.9 years (38 to 78) underwent reconstruction using this technique.

At a mean follow-up of 12 years (8 to 20) 57 patients were alive, 14 had died and one was lost to follow-up. Further revision was performed in 19 hips at a mean of 44.5 months (11 to 153) post-operatively. Causes of failure were aseptic loosening in four, allograft resorption in three, allograft nonunion in two, allograft fracture in four, fracture of the stem in one, and deep infection in five. The survivorship of the allograft-prosthesis composite at ten years was 69.0% (95% confidence interval 67.7 to 70.3) with 26 patients remaining at risk. Survivorship was statistically significantly affected by the severity of the pre-operative bone loss (Paprosky type IV; p = 0.019), the number of previous hip revisions exceeding two (p = 0.047), and the length of the allograft used (p = 0.005).


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 10 | Pages 1278 - 1283
1 Oct 2008
Eswaramoorthy V Moonot P Kalairajah Y Biant LC Field RE

We report the clinical and radiological outcome at ten years of 104 primary total hip replacements (100 patients) using the Metasul metal-on-metal bearing. Of these, 52 had a cemented Stuehmer-Weber polyethylene acetabular component with a Metasul bearing and 52 had an uncemented Allofit acetabular component with a Metasul liner. A total of 15 patients (16 hips) died before their follow-up at ten years and three were lost to follow-up. The study group therefore comprised 82 patients (85 hips). The mean Oxford score at ten years was 20.7 (12 to 42). Six of 85 hips required revision surgery. One was performed because of infection, one for aseptic loosening of the acetabular component and four because of unexplained pain. Histological examination showed an aseptic lymphocytic vasculitis associated lesion-type tissue response in two of these. Continued follow-up is advocated in order to monitor the long-term performance of the Metasul bearing and tissue responses to metal debris


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 4 | Pages 460 - 466
1 Apr 2006
Keizer SB Kock NB Dijkstra PDS Taminiau AHM Nelissen RGHH

This retrospective study describes the long-term results of core decompression and placement of a non-vascularised bone graft in the management of avascular necrosis of the femoral head. We treated 80 hips in 65 patients, 18 by a cortical tibial autograft and 62 by a fibular allograft. The mean age of the patients was 36 years (sd 13.2). A total of 78 hips were available for evaluation of which pre-operatively six were Ficat-Arlet stage 0, three stage I, 31 stage IIA, 16 stage IIB, 13 stage III and nine stage IV.

A total of 34 hips (44%) were revised at a mean of four years (sd 3.8). Survivorship analysis using a clinical end-point showed a survival rate of 59% five years after surgery. We found a significant difference (p = 0.002) in survivorship, when using a clinical and radiological end-point, between the two grafts, in favour of the tibial autograft. We considered this difference to be the result of the better quality and increased volume of tibial bone compared with that from the trochanteric region used with the fibular allograft.

This is a relatively simple, extra-articular and reproducible procedure. In our view core decompression, removal of the necrotic tissue and packing of the cancellous grafts into the core track are vital parts of the procedure.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 2 | Pages 190 - 194
1 Mar 2004
Bizot P Hannouche D Nizard R Witvoet J Sedel L

Between 1990 and 1992, we implanted 71 hybrid alumina-on-alumina hip arthroplasties in 62 consecutive patients under the age of 55 years, with a mean age of 46 years at surgery. There were 56 primary and 15 secondary procedures. The prostheses involved a cemented titanium alloy stem, a 32 mm alumina head, and a press-fit metal-backed socket with an alumina insert. Three patients (four hips) died from unrelated causes. Four hips had revision surgery for either deep infection, unexplained persistent pain, fracture of the alumina head, or aseptic loosening of the socket. The nine-year survival rate was 93.7% with revision for any cause as the end-point and 98.4% with revision for aseptic loosening as the end-point. The outcome in the surviving patients (50 patients, 57 hips) with a minimum five-year follow-up (mean eight years) was excellent in 47 hips (82.5%), very good in eight (14%), good in one and fair in one. A thin, partial, lucent line, mainly in zone III was present in 38% of the sockets and one socket had a complete lucency less than 1 mm thick. One stem had isolated femoral osteolysis. There was no detectable component migration nor acetabular osteolysis. This hybrid arthroplasty gave satisfactory medium-term results in active patients. The press-fit metal-backed socket appeared to have reliable fixation in alumina-on-alumina hip arthroplasty. The excellent results using cemented fixation of the stem may be related to the low production of wear debris


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 3 | Pages 380 - 388
1 Apr 2003
Tidermark J Ponzer S Svensson O Söderqvist A Törnkvist H

The treatment algorithms for displaced fractures of the femoral neck need to be improved if we are to reduce the need for secondary surgery. We have studied 102 patients of mean age 80 years, with an acute displaced fracture of the femoral neck. They were randomly placed into two groups, treated either by internal fixation (IF) with two cannulated screws or total hip replacement (THR). None showed severe cognitive dysfunction, all were able to walk independently, and all lived in their own home. They were reviewed at four, 12 and 24 months after surgery. Outcome measurements included hip complications, revision surgery, hip function according to Charnley and the health-related quality of life (HRQoL) according to EuroQol (EQ-5D). The failure rate after 24 months was higher in the IF group than in the THR group with regard to hip complications (36% and 4%, respectively; p < 0.001), and the number of revision procedures (42% and 4%, p < 0.001). Hip function was significantly better in the THR group at all follow-up reviews regarding pain (p < 0.005), movement (p < 0.05 except at 4 months) and walking (p < 0.05). The reduction in HRQoL (EQ-5D . index. score) was also significantly lower in the THR group than in the IF group, comparing the pre-fracture situation with that at all follow-up reviews (p < 0.05). The results of our study strongly suggest that THR provides a better outcome than IF for elderly, relatively healthy, lucid patients with a displaced fracture of the femoral neck


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 2 | Pages 265 - 269
1 Mar 1992
Roberts P Walters A McMinn D

In 78 consecutive patients, we performed fine-needle aspiration of the hip before revision surgery. At the revision operation biopsies were taken from the capsule and joint tissues. The aspirate and the homogenised soft-tissue specimens were cultured using a radiometric technique. Fifteen hips proved to be infected and 63 sterile on culture of the tissues taken during revision surgery; 94% of the aspiration results were correct. The sensitivity of the technique was 87% and the specificity 95%. Fine-needle aspiration combined with a radiometric culture technique is a simple and reliable method of diagnosing infection of hip prostheses


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 6 | Pages 899 - 901
1 Nov 1991
McMinn D Roberts P Forward G

A new approach to the hip is described that allows better exposure for difficult revision surgery without the need for trochanteric osteotomy. A V-shaped myofascial flap consisting of the proximal part of vastus lateralis and its fascia with gluteus medius and minimus, is reflected off the greater trochanter and proximal femur giving access to the entire capsule of the hip. If the leg has been significantly lengthened by the revision procedure, abductor tension can be adjusted at closure by altering the reattachment of the flap, analogous to a V-Y-plasty.