Aims. The aim of this study was to determine whether there is a correlation between the grade of humeral
Aims. The aim of this study is to evaluate the change in incidence rate of shoulder arthroplasty, indications, and surgeon volume trends associated with these procedures between January 2003 and April 2021 in the province of Nova Scotia, Canada. Methods. A total of 1,545 patients between 2005 and 2021 were analyzed. Patients operated on between 2003 and 2004 were excluded due to a lack of electronic records. Overall, 84.1% of the surgeries (n = 1,299) were performed by two fellowship-trained upper limb surgeons, with the remainder performed by one of the 14 orthopaedic surgeons working in the province. Results. Total shoulder arthroplasty (TSA) was the most frequent procedure (32.17%; n = 497), followed by stemmed hemiarthroplasty (SHA) (27.7%; n = 428). The most frequent indication for primary shoulder arthroplasty was degenerative
Body exhaust suits or surgical helmet systems (colloquially, ‘space suits’) are frequently used in many forms of arthroplasty, with the aim of providing personal protection to surgeons and, perhaps, reducing periprosthetic joint infections, although this has not consistently been borne out in systematic reviews and registry studies. To date, no large-scale study has investigated whether this is applicable to shoulder arthroplasty. We used the New Zealand Joint Registry to assess whether the use of surgical helmet systems was associated with lower all-cause revision or revision for deep infection in primary shoulder arthroplasties. We analyzed 16,000 shoulder arthroplasties (hemiarthroplasties, anatomical, and reverse geometry prostheses) recorded on the New Zealand Joint Registry from its inception in 2000 to the present day. We assessed patient factors including age, BMI, sex, and American Society of Anesthesiologists (ASA) grade, as well as whether or not the operation took place in a laminar flow operating theatre.Aims
Methods
Aims. To report early (two-year) postoperative findings from a randomized controlled trial (RCT) investigating disease-specific quality of life (QOL), clinical, patient-reported, and radiological outcomes in patients undergoing a total shoulder arthroplasty (TSA) with a second-generation uncemented trabecular metal (TM) glenoid versus a cemented polyethylene glenoid (POLY) component. Methods. Five fellowship-trained surgeons from three centres participated. Patients aged between 18 and 79 years with a primary diagnosis of glenohumeral
Aims. The aim of this study was to describe a quantitative 3D CT method to measure rotator cuff muscle volume, atrophy, and balance in healthy controls and in three pathological shoulder cohorts. Methods. In all, 102 CT scans were included in the analysis: 46 healthy, 21 cuff tear arthropathy (CTA), 18 irreparable rotator cuff tear (IRCT), and 17 primary
Shoulder arthroplasty is effective in the management of end-stage glenohumeral joint arthritis. However, it is major surgery and patients must balance multiple factors when considering the procedure. An understanding of patients’ decision-making processes may facilitate greater support of those considering shoulder arthroplasty and inform the outcomes of future research. Participants were recruited from waiting lists of three consultant upper limb surgeons across two NHS hospitals. Semi-structured interviews were conducted with 12 participants who were awaiting elective shoulder arthroplasty. Transcribed interviews were analyzed using a grounded theory approach. Systematic coding was performed; initial codes were categorized and further developed into summary narratives through a process of discussion and refinement. Data collection and analyses continued until thematic saturation was reached.Aims
Methods
The aim of this study is to report the implant survival and factors associated with revision of total elbow arthroplasty (TEA) using data from the Dutch national registry. All TEAs recorded in the Dutch national registry between 2014 and 2020 were included. The Kaplan-Meier method was used for survival analysis, and a logistic regression model was used to assess the factors associated with revision.Aims
Methods
Optimal glenoid positioning in reverse shoulder arthroplasty (RSA) is crucial to provide impingement-free range of motion (ROM). Lateralization and inclination correction are not yet systematically used. Using planning software, we simulated the most used glenoid implant positions. The primary goal was to determine the configuration that delivers the best theoretical impingement-free ROM. With the use of a 3D planning software (Blueprint) for RSA, 41 shoulders in 41 consecutive patients (17 males and 24 females; means age 73 years (SD 7)) undergoing RSA were planned. For the same anteroposterior positioning and retroversion of the glenoid implant, four different glenoid baseplate configurations were used on each shoulder to compare ROM: 1) no correction of the RSA angle and no lateralization (C-L-); 2) correction of the RSA angle with medialization by inferior reaming (C+M+); 3) correction of the RSA angle without lateralization by superior compensation (C+L-); and 4) correction of the RSA angle and additional lateralization (C+L+). The same humeral inlay implant and positioning were used on the humeral side for the four different glenoid configurations with a 3 mm symmetric 135° inclined polyethylene liner.Aims
Methods
The Bankart and Latarjet procedures are two of the most common surgical techniques to treat anterior shoulder instability with satisfactory clinical and functional outcomes. However, the outcomes in the adolescent population remain unclear, and there is no information regarding the arthroscopic Latarjet in this population. The purpose of this study was to evaluate the outcomes of the arthroscopic Bankart and arthroscopic Latarjet procedures in the management of anterior shoulder instability in adolescents. We present a retrospective, matched-pair study of teenagers with anterior glenohumeral instability treated with an arthroscopic Bankart repair (ABR) or an arthroscopic Latarjet (AL) procedure with a minimum two-year follow-up. Preoperative demographic and clinical features, factors associated with dislocation, and complications were collected. Recurrence, defined as dislocation or subluxation, was established as the primary outcome. Clinical and functional outcomes were analyzed using objective (Rowe), and subjective (Western Ontario Shoulder Instability Index (WOSI) and Single Assessment Numeric Evaluation (SANE)) scores. Additionally, the rate of return to sport was assessed.Aims
Methods
There are concerns regarding complications and longevity of total elbow arthroplasty (TEA) in young patients, and the few previous publications are mainly limited to reports on linked elbow devices. We investigated the clinical outcome of unlinked TEA for patients aged less than 50 years with rheumatoid arthritis (RA). We retrospectively reviewed the records of 26 elbows of 21 patients with RA who were aged less than 50 years who underwent primary TEA with an unlinked elbow prosthesis. The mean patient age was 46 years (35 to 49), and the mean follow-up period was 13.6 years (6 to 27). Outcome measures included pain, range of motion, Mayo Elbow Performance Score (MEPS), radiological evaluation for radiolucent line and loosening, complications, and revision surgery with or without implant removal.Aims
Methods
The Mathys Affinis Short is the most frequently used stemless total shoulder prosthesis in the UK. The purpose of this prospective cohort study is to report the survivorship, clinical, and radiological outcomes of the first independent series of the Affinis Short prosthesis. From January 2011 to January 2019, a total of 141 Affinis Short prostheses were implanted in 127 patients by a single surgeon. Mean age at time of surgery was 68 (44 to 89). Minimum one year and maximum eight year follow-up (mean 3.7 years) was analyzed using the Oxford Shoulder Score (OSS) at latest follow-up. Kaplan-Meier survivorship analysis was performed with implant revision as the endpoint. Most recently performed radiographs were reviewed for component radiolucent lines (RLLs) and proximal humeral migration.Aims
Methods