header advert
Results 1 - 20 of 65
Results per page:
Bone & Joint Open
Vol. 5, Issue 8 | Pages 644 - 651
7 Aug 2024
Hald JT Knudsen UK Petersen MM Lindberg-Larsen M El-Galaly AB Odgaard A

Aims

The aim of this study was to perform a systematic review and bias evaluation of the current literature to create an overview of risk factors for re-revision following revision total knee arthroplasty (rTKA).

Methods

A systematic search of MEDLINE and Embase was completed in accordance with the Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) guidelines. The studies were required to include a population of index rTKAs. Primary or secondary outcomes had to be re-revision. The association between preoperative factors and the effect on the risk for re-revision was also required to be reported by the studies.


Bone & Joint Open
Vol. 5, Issue 8 | Pages 621 - 627
1 Aug 2024
Walter N Loew T Hinterberger T Alt V Rupp M

Aims

Fracture-related infections (FRIs) are a devastating complication of fracture management. However, the impact of FRIs on mental health remains understudied. The aim of this study was a longitudinal evaluation of patients’ psychological state, and expectations for recovery comparing patients with recurrent FRI to those with primary FRI.

Methods

A prospective longitudinal study was conducted at a level 1 trauma centre from January 2020 to December 2022. In total, 56 patients treated for FRI were enrolled. The ICD-10 symptom rating (ISR) and an expectation questionnaire were assessed at five timepoints: preoperatively, one month postoperatively, and at three, six, and 12 months.


Bone & Joint Open
Vol. 5, Issue 7 | Pages 560 - 564
7 Jul 2024
Meißner N Strahl A Rolvien T Halder AM Schrednitzki D

Aims

Transfusion after primary total hip arthroplasty (THA) has become rare, and identification of causative factors allows preventive measures. The aim of this study was to determine patient-specific factors that increase the risk of needing a blood transfusion.

Methods

All patients who underwent elective THA were analyzed retrospectively in this single-centre study from 2020 to 2021. A total of 2,892 patients were included. Transfusion-related parameters were evaluated. A multiple logistic regression was performed to determine whether age, BMI, American Society of Anesthesiologists (ASA) grade, sex, or preoperative haemoglobin (Hb) could predict the need for transfusion within the examined patient population.


Bone & Joint Open
Vol. 5, Issue 6 | Pages 479 - 488
6 Jun 2024
Paksoy A Meller S Schwotzer F Moroder P Trampuz A Imiolczyk J Perka C Hackl M Plachel F Akgün D

Aims. Current diagnostic tools are not always able to effectively identify periprosthetic joint infections (PJIs). Recent studies suggest that circulating microRNAs (miRNAs) undergo changes under pathological conditions such as infection. The aim of this study was to analyze miRNA expression in hip arthroplasty PJI patients. Methods. This was a prospective pilot study, including 24 patients divided into three groups, with eight patients each undergoing revision of their hip arthroplasty due to aseptic reasons, and low- and high-grade PJI, respectively. The number of intraoperative samples and the incidence of positive cultures were recorded for each patient. Additionally, venous blood samples and periarticular tissue samples were collected from each patient to determine miRNA expressions between the groups. MiRNA screening was performed by small RNA-sequencing using the miRNA next generation sequencing (NGS) discovery (miND) pipeline. Results. Overall, several miRNAs in plasma and tissue were identified to be progressively deregulated according to ongoing PJI. When comparing the plasma samples, patients with a high-grade infection showed significantly higher expression levels for hsa-miR-21-3p, hsa-miR-1290, and hsa-miR-4488, and lower expression levels for hsa-miR-130a-3p and hsa-miR-451a compared to the aseptic group. Furthermore, the high-grade group showed a significantly higher regulated expression level of hsa-miR-1260a and lower expression levels for hsa-miR-26a-5p, hsa-miR-26b-5p, hsa-miR-148b-5p, hsa-miR-301a-3p, hsa-miR-451a, and hsa-miR-454-3p compared to the low-grade group. No significant differences were found between the low-grade and aseptic groups. When comparing the tissue samples, the high-grade group showed significantly higher expression levels for 23 different miRNAs and lower expression levels for hsa-miR-2110 and hsa-miR-3200-3p compared to the aseptic group. No significant differences were found in miRNA expression between the high- and low-grade groups, as well as between the low-grade and aseptic groups. Conclusion. With this prospective pilot study, we were able to identify a circulating miRNA signature correlating with high-grade PJI compared to aseptic patients undergoing hip arthroplasty revision. Our data contribute to establishing miRNA signatures as potential novel diagnostic and prognostic biomarkers for PJI. Cite this article: Bone Jt Open 2024;5(6):479–488


Bone & Joint Open
Vol. 5, Issue 4 | Pages 367 - 373
26 Apr 2024
Reinhard J Lang S Walter N Schindler M Bärtl S Szymski D Alt V Rupp M

Aims. Periprosthetic joint infection (PJI) demonstrates the most feared complication after total joint replacement (TJR). The current work analyzes the demographic, comorbidity, and complication profiles of all patients who had in-hospital treatment due to PJI. Furthermore, it aims to evaluate the in-hospital mortality of patients with PJI and analyze possible risk factors in terms of secondary diagnosis, diagnostic procedures, and complications. Methods. In a retrospective, cross-sectional study design, we gathered all patients with PJI (International Classification of Diseases (ICD)-10 code: T84.5) and resulting in-hospital treatment in Germany between 1 January 2019 and 31 December 2022. Data were provided by the Institute for the Hospital Remuneration System in Germany. Demographic data, in-hospital deaths, need for intensive care therapy, secondary diagnosis, complications, and use of diagnostic instruments were assessed. Odds ratios (ORs) with 95% confidence intervals (CIs) for in-hospital mortality were calculated. Results. A total of 52,286 patients were included, of whom 1,804 (3.5%) died. Hypertension, diabetes mellitus, and obesity, the most frequent comorbidities, were not associated with higher in-hospital mortality. Cardiac diseases as atrial fibrillation, cardiac pacemaker, or three-vessel coronary heart disease showed the highest risk for in-hospital mortality. Postoperative anaemia occurred in two-thirds of patients and showed an increased in-hospital mortality (OR 1.72; p < 0.001). Severe complications, such as organ failure, systemic inflammatory response syndrome (SIRS), or septic shock syndrome showed by far the highest association with in-hospital mortality (OR 39.20; 95% CI 33.07 to 46.46; p < 0.001). Conclusion. These findings highlight the menace coming from PJI. It can culminate in multi-organ failure, SIRS, or septic shock syndrome, along with very high rates of in-hospital mortality, thereby highlighting the vulnerability of these patients. Particular attention should be paid to patients with cardiac comorbidities such as atrial fibrillation or three-vessel coronary heart disease. Risk factors should be optimized preoperatively, anticoagulant therapy stopped and restarted on time, and sufficient patient blood management should be emphasized. Cite this article: Bone Jt Open 2024;5(4):367–373


Bone & Joint Open
Vol. 5, Issue 4 | Pages 277 - 285
8 Apr 2024
Khetan V Baxter I Hampton M Spencer A Anderson A

Aims

The mean age of patients undergoing total knee arthroplasty (TKA) has reduced with time. Younger patients have increased expectations following TKA. Aseptic loosening of the tibial component is the most common cause of failure of TKA in the UK. Interest in cementless TKA has re-emerged due to its encouraging results in the younger patient population. We review a large series of tantalum trabecular metal cementless implants in patients who are at the highest risk of revision surgery.

Methods

A total of 454 consecutive patients who underwent cementless TKA between August 2004 and December 2021 were reviewed. The mean follow-up was ten years. Plain radiographs were analyzed for radiolucent lines. Patients who underwent revision TKA were recorded, and the cause for revision was determined. Data from the National Joint Registry for England, Wales, Northern Island, the Isle of Man and the States of Guernsey (NJR) were compared with our series.


Bone & Joint Open
Vol. 5, Issue 4 | Pages 260 - 268
1 Apr 2024
Broekhuis D Meurs WMH Kaptein BL Karunaratne S Carey Smith RL Sommerville S Boyle R Nelissen RGHH

Aims

Custom triflange acetabular components (CTACs) play an important role in reconstructive orthopaedic surgery, particularly in revision total hip arthroplasty (rTHA) and pelvic tumour resection procedures. Accurate CTAC positioning is essential to successful surgical outcomes. While prior studies have explored CTAC positioning in rTHA, research focusing on tumour cases and implant flange positioning precision remains limited. Additionally, the impact of intraoperative navigation on positioning accuracy warrants further investigation. This study assesses CTAC positioning accuracy in tumour resection and rTHA cases, focusing on the differences between preoperative planning and postoperative implant positions.

Methods

A multicentre observational cohort study in Australia between February 2017 and March 2021 included consecutive patients undergoing acetabular reconstruction with CTACs in rTHA (Paprosky 3A/3B defects) or tumour resection (including Enneking P2 peri-acetabular area). Of 103 eligible patients (104 hips), 34 patients (35 hips) were analyzed.


Bone & Joint Open
Vol. 4, Issue 12 | Pages 923 - 931
4 Dec 2023
Mikkelsen M Rasmussen LE Price A Pedersen AB Gromov K Troelsen A

Aims

The aim of this study was to describe the pattern of revision indications for unicompartmental knee arthroplasty (UKA) and total knee arthroplasty (TKA) and any change to this pattern for UKA patients over the last 20 years, and to investigate potential associations to changes in surgical practice over time.

Methods

All primary knee arthroplasty surgeries performed due to primary osteoarthritis and their revisions reported to the Danish Knee Arthroplasty Register from 1997 to 2017 were included. Complex surgeries were excluded. The data was linked to the National Patient Register and the Civil Registration System for comorbidity, mortality, and emigration status. TKAs were propensity score matched 4:1 to UKAs. Revision risks were compared using competing risk Cox proportional hazard regression with a shared γ frailty component.


Bone & Joint Open
Vol. 4, Issue 12 | Pages 914 - 922
1 Dec 2023
Sang W Qiu H Xu Y Pan Y Ma J Zhu L

Aims

Unicompartmental knee arthroplasty (UKA) is the preferred treatment for anterior medial knee osteoarthritis (OA) owing to the rapid postoperative recovery. However, the risk factors for UKA failure remain controversial.

Methods

The clinical data of Oxford mobile-bearing UKAs performed between 2011 and 2017 with a minimum follow-up of five years were retrospectively analyzed. Demographic, surgical, and follow-up data were collected. The Cox proportional hazards model was used to identify the risk factors that contribute to UKA failure. Kaplan-Meier survival was used to compare the effect of the prosthesis position on UKA survival.


Bone & Joint Open
Vol. 4, Issue 11 | Pages 881 - 888
21 Nov 2023
Denyer S Eikani C Sheth M Schmitt D Brown N

Aims. The diagnosis of periprosthetic joint infection (PJI) can be challenging as the symptoms are similar to other conditions, and the markers used for diagnosis have limited sensitivity and specificity. Recent research has suggested using blood cell ratios, such as platelet-to-volume ratio (PVR) and platelet-to-lymphocyte ratio (PLR), to improve diagnostic accuracy. The aim of the study was to further validate the effectiveness of PVR and PLR in diagnosing PJI. Methods. A retrospective review was conducted to assess the accuracy of different marker combinations for diagnosing chronic PJI. A total of 573 patients were included in the study, of which 124 knees and 122 hips had a diagnosis of chronic PJI. Complete blood count and synovial fluid analysis were collected. Recently published blood cell ratio cut-off points were applied to receiver operating characteristic curves for all markers and combinations. The area under the curve (AUC), sensitivity, specificity, and positive and negative predictive values were calculated. Results. The results of the analysis showed that the combination of ESR, CRP, synovial white blood cell count (Syn. WBC), and polymorphonuclear neutrophil percentage (PMN%) with PVR had the highest AUC of 0.99 for knees, with sensitivity of 97.73% and specificity of 100%. Similarly, for hips, this combination had an AUC of 0.98, sensitivity of 96.15%, and specificity of 100.00%. Conclusion. This study supports the use of PVR calculated from readily available complete blood counts, combined with established markers, to improve the accuracy in diagnosing chronic PJI in both total hip and knee arthroplasties. Cite this article: Bone Jt Open 2023;4(11):881–888


Bone & Joint Open
Vol. 4, Issue 11 | Pages 859 - 864
13 Nov 2023
Chen H Chan VWK Yan CH Fu H Chan P Chiu K

Aims. The surgical helmet system (SHS) was developed to reduce the risk of periprosthetic joint infection (PJI), but the evidence is contradictory, with some studies suggesting an increased risk of PJI due to potential leakage through the glove-gown interface (GGI) caused by its positive pressure. We assumed that SHS and glove exchange had an impact on the leakage via GGI. Methods. There were 404 arthroplasty simulations with fluorescent gel, in which SHS was used (H+) or not (H-), and GGI was sealed (S+) or not (S-), divided into four groups: H+S+, H+S-, H-S+, and H-S-, varying by exposure duration (15 to 60 minutes) and frequency of glove exchanges (0 to 6 times). The intensity of fluorescent leakage through GGI was quantified automatically with an image analysis software. The effect of the above factors on fluorescent leakage via GGI were compared and analyzed. Results. The leakage intensity increased with exposure duration and frequency of glove exchanges in all groups. When SHS was used and GGI was not sealed (H+S-), the leakage intensity via GGI had the fastest increase, consistently higher than other groups (H+S+, H-S+ and H-S-) after 30 minutes (p < 0.05) and when there were more than four instances of glove exchange (p < 0.05). Additionally, the leakage was strongly correlated with the duration of exposure (r. s. = 0.8379; p < 0.050) and the frequency of glove exchange (r. s. = 0.8198; p < 0.050) in H+S-. The correlations with duration and frequency turned weak when SHS was not used (H-) or GGI was sealed off (S+). Conclusion. Due to personal protection, SHS is recommended in arthroplasties. Meanwhile, it is strongly recommended to seal the GGI of the inner gloves and exchange the outer gloves hourly to reduce the risk of contamination from SHS. Cite this article: Bone Jt Open 2023;4(11):859–864


Bone & Joint Open
Vol. 4, Issue 11 | Pages 832 - 838
3 Nov 2023
Pichler L Li Z Khakzad T Perka C Pumberger M Schömig F

Aims. Implant-related postoperative spondylodiscitis (IPOS) is a severe complication in spine surgery and is associated with high morbidity and mortality. With growing knowledge in the field of periprosthetic joint infection (PJI), equivalent investigations towards the management of implant-related infections of the spine are indispensable. To our knowledge, this study provides the largest description of cases of IPOS to date. Methods. Patients treated for IPOS from January 2006 to December 2020 were included. Patient demographics, parameters upon admission and discharge, radiological imaging, and microbiological results were retrieved from medical records. CT and MRI were analyzed for epidural, paravertebral, and intervertebral abscess formation, vertebral destruction, and endplate involvement. Pathogens were identified by CT-guided or intraoperative biopsy, intraoperative tissue sampling, or implant sonication. Results. A total of 32 cases of IPOS with a mean patient age of 68.7 years (37.6 to 84.1) were included. Diabetes, age > 60 years, and history of infection were identified as risk factors. Patient presentation upon admission included a mean body temperature of 36.7°C (36.1 to 38.0), back pain at rest (mean visual analogue scale (VAS) mean 5/10) and when mobile (mean VAS 6/10), as well as elevated levels of CRP (mean 76.8 mg/l (0.4 to 202.9)) and white blood cell count (mean 9.2 units/nl (2.6 to 32.8)). Pathogens were identified by CT-guided or conventional biopsy, intraoperative tissue sampling, or sonication, and Gram-positive cocci presented as the most common among them. Antibiotic therapy was established in all cases with pathogen-specific treatment in 23 (71.9%) subjects. Overall 27 (84.4%) patients received treatment by debridement, decompression, and fusion of the affected segment. Conclusion. Cases of IPOS are rare and share similarities with spontaneous spondylodiscitis. While procedures such as CT-guided biopsy and sonication are valuable tools in the diagnosis of IPOS, MRI and intraoperative tissue sampling remain the gold standard. Research on known principles of PJI such as implant retention versus implant exchange need to be expanded to the field of spine surgery. Cite this article: Bone Jt Open 2023;4(11):832–838


Bone & Joint Open
Vol. 4, Issue 10 | Pages 776 - 781
16 Oct 2023
Matar HE Bloch BV James PJ

Aims

The aim of this study was to evaluate medium- to long-term outcomes and complications of the Stanmore Modular Individualised Lower Extremity System (SMILES) rotating hinge implant in revision total knee arthroplasty (rTKA) at a tertiary unit. It is hypothesized that this fully cemented construct leads to satisfactory clinical outcomes.

Methods

A retrospective consecutive study of all patients who underwent a rTKA using the fully cemented SMILES rotating hinge prosthesis between 2005 to 2018. Outcome measures included aseptic loosening, reoperations, revision for any cause, complications, and survivorship. Patients and implant survivorship data were identified through both prospectively collected local hospital electronic databases and linked data from the National Joint Registry/NHS Personal Demographic Service. Kaplan-Meier survival analysis was used at ten years.


Bone & Joint Open
Vol. 4, Issue 10 | Pages 742 - 749
6 Oct 2023
Mabrouk A Abouharb A Stewart G Palan J Pandit H

Aims. Prophylactic antibiotic regimens for elective primary total hip and knee arthroplasty vary widely across hospitals and trusts in the UK. This study aimed to identify antibiotic prophylaxis regimens currently in use for elective primary arthroplasty across the UK, establish variations in antibiotic prophylaxis regimens and their impact on the risk of periprosthetic joint infection (PJI) in the first-year post-index procedure, and evaluate adherence to current international consensus guidance. Methods. The guidelines for the primary and alternative recommended prophylactic antibiotic regimens in clean orthopaedic surgery (primary arthroplasty) for 109 hospitals and trusts across the UK were sought by searching each trust and hospital’s website (intranet webpages), and by using the MicroGuide app. The mean cost of each antibiotic regimen was calculated using price data from the British National Formulary (BNF). Regimens were then compared to the 2018 Philadelphia Consensus Guidance, to evaluate adherence to international guidance. Results. The primary choice and dosing of the prophylactic antimicrobial regimens varied widely. The two most used regimens were combined teicoplanin and gentamicin, and cefuroxime followed by two or three doses of cefuroxime eight-hourly, recommended by 24 centres (22.02%) each. The alternative choice and dosing of the prophylactic antimicrobial regimen also varied widely across the 83 centres with data available. Prophylaxis regimens across some centres fail to cover the likeliest causes of surgical site infection (SSI). Five centres (4.59%) recommend co-amoxiclav, which confers no Staphylococcus coverage, while 33 centres (30.28%) recommend cefuroxime, which confers no Enterococcus coverage. Limited adherence to 2018 Philadelphia Consensus Guidance was observed, with 67 centres (61.50%) not including a cephalosporin in their guidance. Conclusion. This analysis of guidance on antimicrobial prophylaxis in primary arthroplasty across 109 hospitals and trusts in the UK has identified widespread variation in primary and alternative antimicrobial regimens currently recommended. Cite this article: Bone Jt Open 2023;4(10):742–749


Aims. Achievement of accurate microbiological diagnosis prior to revision is key to reducing the high rates of persistent infection after revision knee surgery. The effect of change in the microorganism between the first- and second-stage revision of total knee arthroplasty for periprosthetic joint infection (PJI) on the success of management is not clear. Methods. A two-centre retrospective cohort study was conducted to review the outcome of patients who have undergone two-stage revision for treatment of knee arthroplasty PJI, focusing specifically on isolated micro-organisms at both the first- and second-stage procedure. Patient demographics, medical, and orthopaedic history data, including postoperative outcomes and subsequent treatment, were obtained from the electronic records and medical notes. Results. The study cohort consisted of 84 patients, of whom 59.5% (n = 50) had successful eradication of their infection at a mean follow-up of 4.7 years. For the 34 patients who had recurrence of infection, 58.8% (n = 20) had a change in isolated organism, compared to 18% (n = 9) in the infection eradication group (p < 0.001). When adjusting for confound, there was no association when the growth on the second stage was the same as the first (odd ratio (OR) 2.50, 95% confidence interval (CI) 0.49 to 12.50; p = 0.269); however, when a different organism was identified at the second stage, this was independently associated with failure of treatment (OR 8.40, 95% CI 2.91 to 24.39; p < 0.001). There were no other significant differences between the two cohorts with regard to patient demographics or type of organisms isolated. Conclusion. Change in the identified microorganism between first- and second-stage revision for PJI was associated with failure of management. Identification of this change in the microorganism prior to commencement of the second stage may help target antibiotic management and could improve the success of surgery in these patients. Cite this article: Bone Jt Open 2023;4(9):720–727


Bone & Joint Open
Vol. 4, Issue 8 | Pages 621 - 627
22 Aug 2023
Fishley WG Paice S Iqbal H Mowat S Kalson NS Reed M Partington P Petheram TG

Aims

The rate of day-case total knee arthroplasty (TKA) in the UK is currently approximately 0.5%. Reducing length of stay allows orthopaedic providers to improve efficiency, increase operative throughput, and tackle the rising demand for joint arthroplasty surgery and the COVID-19-related backlog. Here, we report safe delivery of day-case TKA in an NHS trust via inpatient wards with no additional resources.

Methods

Day-case TKAs, defined as patients discharged on the same calendar day as surgery, were retrospectively reviewed with a minimum follow-up of six months. Analysis of hospital and primary care records was performed to determine readmission and reattendance rates. Telephone interviews were conducted to determine patient satisfaction.


Bone & Joint Open
Vol. 4, Issue 8 | Pages 628 - 635
22 Aug 2023
Hedlundh U Karlsson J Sernert N Haag L Movin T Papadogiannakis N Kartus J

Aims. A revision for periprosthetic joint infection (PJI) in total hip arthroplasty (THA) has a major effect on the patient’s quality of life, including walking capacity. The objective of this case control study was to investigate the histological and ultrastructural changes to the gluteus medius tendon (GMED) in patients revised due to a PJI, and to compare it with revision THAs without infection performed using the same lateral approach. Methods. A group of eight patients revised due to a PJI with a previous lateral approach was compared with a group of 21 revised THAs without infection, performed using the same approach. The primary variables of the study were the fibril diameter, as seen in transmission electron microscopy (TEM), and the total degeneration score (TDS), as seen under the light microscope. An analysis of bacteriology, classification of infection, and antibiotic treatment was also performed. Results. Biopsy samples from the GMED from infected patients revealed a larger fibril diameter than control patients, as seen in the TEM (p < 0.001). Uninfected patients were slightly older and had their revisions performed significantly later than the infected patients. Histologically, samples from infected patients revealed significantly more vascularity (p < 0.001), the presence of glycosaminoglycans (p < 0.001), and a higher TDS (p = 0.003) than the control patients. The majority of patients had staphylococcal infections of various species. Conclusion. More histological degeneration in the GMED was found in patients undergoing THA revision surgery due to PJI than in patients undergoing THA revision surgery due to other reasons. Cite this article: Bone Jt Open 2023;4(8):628–635


Bone & Joint Open
Vol. 4, Issue 8 | Pages 551 - 558
1 Aug 2023
Thomas J Shichman I Ohanisian L Stoops TK Lawrence KW Ashkenazi I Watson DT Schwarzkopf R

Aims

United Classification System (UCS) B2 and B3 periprosthetic fractures in total hip arthroplasties (THAs) have been commonly managed with modular tapered stems. No study has evaluated the use of monoblock fluted tapered titanium stems for this indication. This study aimed to evaluate the effects of a monoblock stems on implant survivorship, postoperative outcomes, radiological outcomes, and osseointegration following treatment of THA UCS B2 and B3 periprosthetic fractures.

Methods

A retrospective review was conducted of all patients who underwent revision THA (rTHA) for periprosthetic UCS B2 and B3 periprosthetic fracture who received a single design monoblock fluted tapered titanium stem at two large, tertiary care, academic hospitals. A total of 72 patients met inclusion and exclusion criteria (68 UCS B2, and four UCS B3 fractures). Primary outcomes of interest were radiological stem subsidence (> 5 mm), radiological osseointegration, and fracture union. Sub-analysis was also done for 46 patients with minimum one-year follow-up.


Bone & Joint Open
Vol. 4, Issue 7 | Pages 516 - 522
10 Jul 2023
Mereddy P Nallamilli SR Gowda VP Kasha S Godey SK Nallamilli RR GPRK R Meda VGR

Aims

Musculoskeletal infection is a devastating complication in both trauma and elective orthopaedic surgeries that can result in significant morbidity. Aim of this study was to assess the effectiveness and complications of local antibiotic impregnated dissolvable synthetic calcium sulphate beads (Stimulan Rapid Cure) in the hands of different surgeons from multiple centres in surgically managed bone and joint infections.

Methods

Between January 2019 and December 2022, 106 patients with bone and joint infections were treated by five surgeons in five hospitals. Surgical debridement and calcium sulphate bead insertion was performed for local elution of antibiotics in high concentration. In all, 100 patients were available for follow-up at regular intervals. Choice of antibiotic was tailor made for each patient in consultation with microbiologist based on the organism grown on culture and the sensitivity. In majority of our cases, we used a combination of vancomycin and culture sensitive heat stable antibiotic after a thorough debridement of the site. Primary wound closure was achieved in 99 patients and a split skin graft closure was done in one patient. Mean follow-up was 20 months (12 to 30).


Bone & Joint Open
Vol. 4, Issue 7 | Pages 472 - 477
1 Jul 2023
Xiang W Tarity TD Gkiatas I Lee H Boettner F Rodriguez JA Wright TM Sculco PK

Aims

When performing revision total hip arthroplasty using diaphyseal-engaging titanium tapered stems (TTS), the recommended 3 to 4 cm of stem-cortical diaphyseal contact may not be available. In challenging cases such as these with only 2 cm of contact, can sufficient axial stability be achieved and what is the benefit of a prophylactic cable? This study sought to determine, first, whether a prophylactic cable allows for sufficient axial stability when the contact length is 2 cm, and second, if differing TTS taper angles (2° vs 3.5°) impact these results.

Methods

A biomechanical matched-pair cadaveric study was designed using six matched pairs of human fresh cadaveric femora prepared so that 2 cm of diaphyseal bone engaged with 2° (right femora) or 3.5° (left femora) TTS. Before impaction, three matched pairs received a single 100 lb-tensioned prophylactic beaded cable; the remaining three matched pairs received no cable adjuncts. Specimens underwent stepwise axial loading to 2600 N or until failure, defined as stem subsidence > 5 mm.