Cervical spondylosis is often accompanied by dizziness. It has
recently been shown that the ingrowth of Ruffini corpuscles into
diseased cervical discs may be related to cervicogenic dizziness.
In order to evaluate whether cervicogenic dizziness stems from the
diseased cervical disc, we performed a prospective cohort study
to assess the effectiveness of anterior cervical discectomy and
fusion on the relief of dizziness. Of 145 patients with cervical spondylosis and dizziness, 116
underwent anterior cervical decompression and fusion and 29 underwent
conservative treatment. All were followed up for one year. The primary
outcomes were measures of the intensity and frequency of dizziness.
Secondary outcomes were changes in the modified Japanese Orthopaedic
Association (mJOA) score and a visual analogue scale score for neck
pain.Aims
Patients and Methods
Between April 2004 and July 2007, we performed 241 primary total knee replacements in 204 patients using the e.motion posterior cruciate-retaining, multidirectional mobile-bearing prosthesis. Of these, 100 were carried out using an image-free navigation system, and the remaining 141 with the conventional technique. We conducted a retrospective study from the prospectively collected data of these patients to assess the early results of this new mobile-bearing design. At a mean follow-up of 49 months (32 to 71), 18 knees (7.5%) had mechanical complications of which 13 required revision. Three of these had a peri-prosthetic fracture, and were removed from the study. The indication for revision in the remaining ten was loosening of the femoral component in two, tibiofemoral dislocation in three, disassociation of the polyethylene liner in four, and a broken polyethyene liner in one. There were eight further mechanically unstable knees which presented with recurrent disassociation of the polyethylene liner. There was no significant difference in the incidence of mechanical instability between the navigation-assisted procedures (8 of 99, 8.1%) and the conventionally implanted knees (10 of 139, 7.2%). In our view, the relatively high rate of mechanical complications and revision within 30 months precludes the further use of new design of knee replacement.
Between March 1990 and May 1991 we performed 85 primary total hip replacements in 74 patients using the Landos Atoll hydroxyapatite (HA)-coated cup and the Corail HA-coated stem. The patients were followed up for a mean of ten years. Of the 85 cups, 26 (31%) have already been revised and a further six are radiologically unstable and awaiting revision. Two femoral stems have been revised for infection without loosening. The retrieved acetabular cups were studied by SEM and image-processing techniques to quantify the amount of residual HA on the cup. This was correlated with the clinical variables and modes of failure. The residual HA (as a percentage of the surface) on the loose cups correlated negatively with the duration of implantation (r = −0.732, p <
0.001). Six cups were stable at revision and had more residual HA coating than those which were loose (p <
0.01). The rate of failure of the Landos Atoll HA-coated, smooth hemispherical cup with screw fixation is unacceptably high. Resorption of the HA coating is markedly increased in loose cups compared with stable cups. HA coating cannot substitute for stable mechanical fixation.
We report our experience of surgical treatment for instability of flail knees after poliomyelitis in 228 patients. We made carefully selective use of soft-tissue release, extension osteotomy of the femur, and a patellar bone block for hyperextension. After six to nine years follow-up, 87% of the patients had retained significant improvement in stability and walking ability.