Advertisement for orthosearch.org.uk
Results 1 - 11 of 11
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 801 - 805
1 Jun 2011
Quah C Boulton C Moran C

This is the first study to use the English Indices of Multiple Deprivation 2007, the Government’s official measure of multiple deprivation, to analyse the effect of socioeconomic status on the incidence of fractures of the hip and their outcome and mortality. Our sample consisted of all patients admitted to hospital with a fracture of the hip (n = 7511) in Nottingham between 1999 and 2009.

The incidence was 1.3 times higher (p = 0.038) in the most deprived populations than in the least deprived; the most deprived suffered a fracture, on average, 1.1 years earlier (82.0 years versus 83.1 years, p < 0.001). The mortality rate proved to be significantly higher in the most deprived population (log-rank test, p = 0.033), who also had a higher number of comorbidities (p = 0.001).

This study has shown an increase in the incidence of fracture of the hip in the most deprived population, but no association between socioeconomic status and mortality at 30 days. Preventative programmes aimed at reducing the risk of hip fracture should be targeted towards the more deprived if they are to make a substantial impact.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 266 - 268
1 Feb 2011
Quinlan CS Walsh JC Moran A Moran C O’Rourke SK

We describe a case of bilateral weakness of the lower limbs, sensory disturbance and intermittent urinary incontinence, secondary to untreated Gitelman’s syndrome, in a 42-year-old female who was referred with presumed cauda equina syndrome. On examination, the power of both legs was uniformly reduced, and the perianal and lower-limb sensation was altered. However, MRI of the lumbar spine was normal. Measurements of serum and urinary potassium were low and blood gas analysis revealed metabolic alkalosis. Her symptoms resolved following potassium replacement.

We emphasise the importance of measurement of the plasma and urinary levels of electrolytes in the investigation of patients with paralysis of the lower limbs and suggest that they, together with blood gas analysis, allow the exclusion of unusual causes of muscle weakness resulting from metabolic disorders such as metabolic alkalosis.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 8 | Pages 985 - 986
1 Aug 2009
Willett K Marsh D Moran C Giannoudis P Bircher M


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 4 | Pages 667 - 668
1 Jul 1995
Moran C Pinder I


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 2 | Pages 258 - 262
1 Mar 1994
Owen T Moran C Smith Pinder I

We reviewed a consecutive series of 241 uncemented, porous-coated anatomic (PCA) hip replacements at an average follow-up of five years (2 to 9). Of these, 32 had failed (13%), 26 at the acetabular component (11%) and six at the femoral component (2%). Acetabular failure was associated with local osteolysis and excessive polyethylene wear in 20 cases: in these histological examination showed giant macrophages incorporating numerous particles of high-density polyethylene. The femoral failures were related to a poor intramedullary fit with subsequent subsidence. Using the recommendation for revision as the end point, the cumulative survival rate for prostheses was 91% at six years (95% CI +/- 6%), 73% (+/- 11%) at seven years, and 57% (+/- 20%) at eight years. The result of uncemented PCA hip replacement is satisfactory up to six years, but then increasing failure of the acetabular component appears to be due to polyethylene wear, leading to osteolysis, loosening and component migration. At first, failure is often asymptomatic; routine follow-up of uncemented hip replacement is essential, especially after five years.


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 6 | Pages 940 - 941
1 Nov 1993
Khaw F Moran C Pinder I Smith

We made a prospective study of the incidence of fatal pulmonary embolism in patients after total knee replacement with no prophylactic anticoagulation. There were 499 consecutive patients having 527 knee replacements. They all wore anti-thromboembolic stockings and were mobilised 48 hours after surgery. No patient was lost to follow-up. One patient died of pulmonary embolism 22 days after operation. There were no other deaths within three months of operation. The incidence of fatal pulmonary embolism was 0.19% (95% confidence interval: 0 to 0.6%). Fatal pulmonary embolism is rare after total knee replacement without prophylactic anticoagulation and the routine anticoagulation of these patients is of doubtful value.


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 6 | Pages 918 - 920
1 Nov 1993
Wright K Moran C Briggs P

Exposure to blood is a hazard for all surgeons. We assessed the incidence of glove perforation and needlestick injury from a new blunt taperpoint needle designed to penetrate tissues other than skin with the minimum of force. We performed a prospective, randomised trial comparing the incidence of perforations of surgical gloves with the new needle and a standard cutting needle during wound closure after hip arthroplasties. There was at least one glove perforation in 46 of 69 such procedures (67%). The use of the taperpoint needle produced a significant decrease in perforations (p = 0.049).


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 1 | Pages 18 - 22
1 Jan 1992
Jones S Pinder I Moran C Malcolm A

Isolated wear of the polyethylene tibial component led to failure in five of a series of 108 uncemented porous-coated knee replacements. The clinical features included pain, effusion and instability with progressive varus deformity. In all cases there was extensive wear on the medial side of the polyethylene surface of the prosthesis. The mechanism of such wear is complex, being due in part to the unconstrained nature of the joint and the incongruity of its surfaces. Other design characteristics may have contributed.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 1 | Pages 11 - 12
1 Jan 1991
Gregory R Gibson M Moran C

Dislocation is the most frequent serious complication following total hip replacement for subcapital femoral fracture. We report a prospective study, using matched groups, which compared the range of hip movement following hip replacement for arthritis and for fracture. The range of movement was significantly greater in the fracture group. We suggest that this is a predisposing factor for dislocation.


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 1 | Pages 19 - 22
1 Jan 1990
Moran C Gibson M Cross A

Fractures of the femoral shaft are generally considered to affect young patients, but we have reviewed 24 cases in patients over 60 years who have been treated by locked nailing, usually by closed methods. Most were women with low-velocity injuries, but despite this, 14 fractures were significantly comminuted. The complication rate was 54% with a peri-operative mortality of 17%. Most complications were the general ones of operating on elderly patients. Specific complications included: fractures below an abnormal hip, proximal fracture related to the nail and poor purchase in the distal femur. In all survivors, the femoral shaft fractures united satisfactorily, and the fixation allowed early mobilisation. The locking nail appears to be an effective method of managing femoral shaft fractures in the elderly patient.


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 4 | Pages 704 - 704
1 Aug 1989
Moran C Kreibich D